ML081960148

From kanterella
Jump to navigation Jump to search

Tech Spec Page for Amendment 179 Regarding TS Changes Related to Surveillance Frequency for Scram Discharge Volume Water Level Float Switch
ML081960148
Person / Time
Site: Clinton 
Issue date: 06/30/2008
From:
NRC/NRR/ADRO/DORL/LPLIII-2
To:
Sands S,NRR/DORL, 415-3154
References
TAC MD4111
Download: ML081960148 (1)


Text

RPS Instrumentation 3.3.1.1 Table 3.3.1.1-1 (page 3 of 3).

Reactor Protection System Instrumentation APPLICABLE CONDITIONS MODES OR REQUIRED REFERENCED OTHER CHANNELS FROM SPECIFIED PER REQUIRED SURVEILLANCE ALLOWABLE FUNCTION CONDITIONS FUNCTION ACTION D.1 REQUIREMENTS VALUE

8.

Scram Discharge Volume Water Level-High (continued)

b.

Float Switch 1,2 H

SR SR SR 3.3.1.1.12

< 763 ft. 3-1/4 3.3.1.1.13 inches msl for 3.3.1.1.15 1Cl-NO13A,B and 5 763 ft.

1-11/16 inches msl for lC1-N013C,D I

5 (a)

9. Turbine Stop Valve Closure > 33.3% RTP 4

I SR SR SR 4

E SR SR SR SR SR E

SR SR SR SR SR 3.3.1.1.12 3.3.1.1.13 3.3.1.1.15 3.3.1.1.9 3.3.1.1.13 3.3.1.1.15 3.3.1.1.16 3.3.1.1.17 3.3.1.1.9 3.3.1.1.13 3.3.1.1.15 3.3.1.1.16 3.3.1.1.17

< 763 ft. 3-1/4 inches msl for lCl1-NO13A,B and S 763 ft.

1-11/16 inches msl for ICII-N013C,D

< 7% closed

10. Turbine Control Valve Fast Closure, Trip Oil Pressure-Low

Ž 33.3% RTP 4

> 465 psig

11. Reactor Mode Switch-Shutdown Position 1,2 5 (a) 1,2 5 (a) 4 4

H SR 3.3.1.1.12 SR 3.3.1.1.15 I

SR 3.3.1.1.12 SR 3.3.1.1.15 H

SR 3.3.1.1.9 SR 3.3.1.1.15 NA NA NA

12. Manual Scram 4

SR 3.3.1.1.9 NA SR 3.3.1.1.15 (a)

With any control rod withdrawn from a core cell containing one, or more fuel assemblies.

CLINTON 3.3-9 Amendment No. 179