ML081700321

From kanterella
Jump to navigation Jump to search
Riverkeeper, Inc.S Supplemental Citation in Support of Admission of Contention EC-2
ML081700321
Person / Time
Site: Indian Point  
Issue date: 06/12/2008
From: Curran D, Musegaas P
Harmon, Curran, Harmon, Curran, Spielberg & Eisenberg, LLP, Riverkeeper
To: Lathrop K, Lawrence Mcdade, Richard Wardwell
Atomic Safety and Licensing Board Panel
SECY RAS
References
50-247-LR, 50-286-LR, RAS-E-110
Download: ML081700321 (13)


Text

A"

- C, _11D COPY June 12, 2008 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION ATOMIC SAFETY AND LICENSING BOARD Before Administrative Judges:

Lawrence G. McDade, Chairman Dr. Richard E. Wardwell Dr. Kaye D. Lathrop DOCKETED USNRC June 12,2008 (11:59am)

OFFICE OF SECRETARY RULEMAKINGS AND ADJUDICATIONS STAFF In the Matter of

))

Entergy Nuclear Operations, Inc.

)

(Indian Point Nuclear Generating

)

Station Units 2 and 3)

)

Docket Nos.

50-247-LR and 50-286-LR RIVERKEEPER, INC.'S SUPPLEMENTAL CITATION IN SUPPORT OF ADMISSION OF CONTENTION EC-2 On May 14, 2008, the U.S. Nuclear Regulatory Commission ("NRC") Staff issued a notice summarizing a telephone conference between the NRC Staff and Entergy Nuclear Operations, Inc. ("Entergy"), concerning a draft Request for Additional Information ("RAI") pertaining to the Severe Accident Mitigation Alternatives

("SAMA") Analysis for Indian Point Units 2 and 3. A copy of the notice is attached, and is also available on ADAMS at ML081160340 (posted May 22, 2008). Proposed Questions 4, 5 and 6, listed in Enclosure 2 of the notice, support Subpart 1 of Riverkeeper, Inc.'s Contention EC-2 by demonstrating that the NRC Staff considers the SAMA analysis in Entergy's Environmental Report to be inadequate to demonstrate that Entergy has properly assessed the likelihood of an accident involving thermally-induced steam generator tube rupture or has considered appropriate mitigation options.

7Dtk PL

- ` St-c ýr-OW

ý S',03

e

mitted, iane Cýurran Harmon, Curran, Spielberg, & Eisenberg, L.L.P.

1726 M Street N.W., Suite 600 Washington, D.C. 20036 202/328-3500 FAX 202/328-6918 de urran(aharmoncurran.corn Phillip Musegaas Staff Attorney Riverkeeper, Inc.

828 South Broadway Tarrytown, NY 10591 914-478-4501 (ext. 224)

Fax 914-478-4527 phi1ipgriverkeeper.org www.riverkeeper.org June 12, 2008 2

May 14, 2008 LICENSEE:

FACILITY:

SUBJECT:

Entergy Nuclear Operations, Inc.

Indian Point Nuclear Generating Unit Nos. 2 and 3

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON MARCH 31, 2008, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC., CONCERNING DRAFT REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE SEVERE ACCIDENT MITIGATION ALTERNATIVES ANALYSIS FOR INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Entergy Nuclear Operations, Inc., held a telephone conference call on March 31, 2008, to discuss and clarify the staff's draft request for additional information (D-RAls) concerning the Indian Point Nuclear Generating Unit Nos. 2 and 3 severe accident mitigation alternative (SAMA) analysis from its license renewal application. The telephone conference call was useful in clarifying the intent of the staff's SAMA D-RAIs. provides a listing of the participants; and Enclosure 2 contains a listing of the D-RAIs discussed with the applicant.

\\RA\\

Bo M. Pham, Senior Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-247 and 50-286

Enclosures:

As stated cc w/encls: See next page

ML081160340 OFFICE LA:DLR PM:RLR:DLR BC:RLR:DLR NAME YEdmonds BPham RFranovich (BPham for) w\\edits DATE 5/12/08 5/14/08 5/14/08

Letter to Enterqy from B. Pham, dated May 14, 2008 DISTRIBUTION:

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON MARCH 31, 2008, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC., CONCERNING DRAFT REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE SEVERE ACCIDENT MITIGATION ALTERNATIVES ANALYSIS FOR INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3, LICENSE RENEWAL APPLICATION HARD COPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDIr RidsNrrDIrRpbl RidsNrrDIrRpb2 RidsNrrDIrRerl RidsNrrDIrRer2 RidsNrrDIrRerb RidsNrrDIrRpob RidsNrrDciCvib RidsNrrDciCpnb RidsNrrDraAfpb RidsNrrDraAplb RidsNrrDeEmcb RidsNrrDeEeeb RidsNrrDssSrxb RidsNrrDssSbpb RidsNrrDssScvb RidsOgcMailCenter RFranovich BPham KGreen JCaverly RAuluck KChang MKowal JBoska STurk, OGC LSubin, OGC BMizuno, OGC SBurnell, OPA DMclntyre, OPA TMensah, OEDO EDacus, OCA GMeyer, RI MMcLaughlin, RI NMcNamara, RI DScrenci, RI OPA NSheehan, RI OPA PCataldo, RI CHott, RI DJackson, RI BWelling, RI RConte, RI ECobey, RI MCox, RI

Indian Point Nuclear Generating Unit Nos. 2 and 3 cc:

Senior Vice President Entergy Nuclear Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Vice President Oversight Entergy Nuclear Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Senior Manager, Nuclear Safety &

Licensing Entergy Nuclear Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Senior Vice President and COO Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Assistant General Counsel Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Manager, Licensing Entergy Nuclear Operations, Inc.

Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 Mr. Paul D. Tonko President and CEO New York State Energy Research and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. John P. Spath New York State Energy, Research and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Paul Eddy New York State Department of Public Service 3 Empire State Plaza Albany, NY 12223-1350 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector's Office Indian Point 2 U.S. Nuclear Regulatory Commission P.O. Box 59 Buchanan, NY 10511 Senior Resident Inspector's Office Indian Point 3 U.S. Nuclear Regulatory Commission P.O. Box 59 Buchanan, NY 10511 Mr. Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Raymond L. Albanese Four County Coordinator 200 Bradhurst Avenue Unit 4 Westchester County Hawthorne, NY 10532 Mayor, Village of Buchanan 236 Tate Avenue Buchanan, NY 10511 Indian Point Nuclear Generating Unit Nos. 2 and 3 cc:

Mr. William DiProfio PWR SRC Consultant 48 Bear Hill Road Newton, NH 03858 Mr. Garry Randolph PWR SRC Consultant 1750 Ben Franklin Drive, 7E Sarasota, FL 34236 Mr. William T. Russell PWR SRC Consultant 400 Plantation Lane Stevensville, MD 21666-3232 Mr. Jim Riccio Greenpeace 702 H Street, NW Suite 300 Washington, DC 20001 Mr. Phillip Musegaas Riverkeeper, Inc.

828 South Broadway Tarrytown, NY 10591 Mr. Mark Jacobs IPSEC 46 Highland Drive Garrison, NY 10524 Mr. R. M. Waters Technical Specialist Licensing 450 Broadway P.O. Box 0249 Buchanan, NY 10511-0249 Mr. Sherwood Martinelli 351 Dyckman Peekskill, NY 10566 Ms. Susan Shapiro, Esq.

21 Perlman Drive Spring Valley, NY 10977 John Sipos Assistant Attorney General New York State Department of Law Environmental Protection Bureau The Capitol Albany, NY 12224 Robert Snook Assistant Attorney General Office of the Attorney General State of Connecticut 55 Elm Street P.O. Box 120 Hartford, CT 06141-0120 Ms. Kathryn M. Sutton, Esq.

Morgan, Lewis & Bockius, LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Mr. Paul M. Bessette, Esq.

Morgan, Lewis & Bockius, LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Mr. Martin J. O'Neill, Esq.

Morgan, Lewis & Bockius, LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 The Honorable Nita Lowey 222 Mamaroneck Avenue, Suite 310 White Plains, NY 10605 Joan Leary Matthews Senior Counsel for Special Projects Office of General Counsel NYS Department of Environmental Conservation 625 Broadway Albany, NY 12233-5500

TELEPHONE CONFERENCE CALL INDIAN POINT NUCLEAR GENERATING UNIT NOS 2 AND 3 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS MARCH 31, 2008 PARTICIPANTS Bo Pham Robert Palla Bruce Mrowca Ali Azarm Mike Stroud Lori Potts John Curry Charles Caputo Clem Yeh Doug Gaynor Kou John Hong John Favara Andy Mihalik John Bretti AFFILIATIONS U.S. Nuclear Regulatory Commission (NRC)

NRC Information Systems Laboratory (ISL)

ISL Entergy Nuclear Operations, Inc. (Entergy)

Entergy Entergy Entergy Entergy Entergy Entergy Entergy Entergy Entergy Entergy Robert Licata ENCLOSURE 1

Draft Request for Additional Information Regarding the Analysis of Severe Accident Mitigation Alternatives for Indian Point Nuclear Generating Unit Nos. 2 and 3

1.

The response to RAI 1 d addresses why the total loss of service water (SW) is low for both units but does not discuss the reason for Unit 2 having a loss of SW contribution that is nearly an order of magnitude lower than Unit 3. Explain the plant or model features that cause this difference.

2.

Explain why the IP3 analysis cases for "DC Power/AFW System Changes," "AC Power Cross-Tie with IP2," and "Backup DC Power Supply" result in no reduction in population dose or offsite economic cost risk (OECR) for the SAMAs considered therein.

3.

In ER Tables E.2-3 and E.4-3, the benefit value for Sensitivity Case 3 (Loss of Tourism and Business) is same as for the Baseline Case for a large number of analysis cases.

Confirm whether Sensitivity Case 3 values were actually calculated when the reduction in population dose and OECR were below some threshold value. If not, several revised benefit values provided in response to RAI 4e (i.e., columns 2 and 3 of the tables) may understate the benefits for the affected SAMAs. The affected SAMAs include:

IP2 SAMAs 4-6, 18, 25-27, 29-32, 34-39, 40, 41-43, 48-50, 56, 59, 63, 64, 67, 68, and IP3 SAMAs 2, 24-26, 28, 29, 32, 33, 35-37, 40, 42, 47, 48, 51, 56, 58, and revised SAMA 30. Update the tables provided in response to RAI 4e, if necessary, to assure that the benefit estimates for the aforementioned SAMAs fully account for the impacts of loss of tourism and business.

4.

The response to RAI 2b indicates that steam generator tube ruptures (SGTRs) induced by high primary side pressures following core damage are addressed in the IP2 PRA model using the information from the NUREG-1 150 In-Vessel Expert Panel, but does not provide the explicit modeling approach. The response associated with IP3 also does not appear to address this issue. Describe the current IP2 and IP3 modeling approach for thermally-induced SGTR events including the conditional probabilities and the associated conditions used to assess the likelihood of a thermally-induced SGTR (TI-SGTR), and the conditional probabilities for a stuck open main steam safety valve during a TI-SGTR event. Provide the bases for these values.

5.

Provide an assessment of the impact on the identification and screening of SGTR-related SAMAs if the conditional probabilities of TI-SGTR (discussed in item 4 above) are increased to values comparable to those reported in NUREG-1570. Provide a further evaluation and discussion of any additional SGTR-related SAMAs that could become potentially cost-beneficial under these assumptions (including the SAMAs addressed by the analysis cases identified in item 2 above) and Entergy's planned follow-up actions regarding these SAMAs.

6.

The SAMA analysis for Beaver Valley Power Station identified as potentially cost-beneficial the purchase or manufacture of a "gagging device" that could be used to close a stuck-open steam generator safety value on the ruptured steam generator prior to core damage in SGTR events. Provide an evaluation of the viability of this SAMA for the Indian Point units, including the estimated costs and benefits under the assumptions of items 5 and 8.

ENCLOSURE 2

7.

The response to RAI 4e states that Sensitivity Case 3 with uncertainty results in two additional SAMAs (009 and 053) for IP2 and one additional SAMA (053) for IP3.

Discuss Entergy's planned follow-up actions regarding these additional SAMAs.

8.

The response to RAI 51 shows a $236,000 contingency cost as part of the cost breakdown. However, Section 4.21.5.4, "Final Screening and Cost/Benefit Evaluation (Phase II)" of the environmental report states that "the cost estimates for implementing the SAMAs did not include the cost of replacement power during extended outages required to implement the modifications, nor did they include contingency cost associated with unforeseen implementation obstacles." Explain this apparent discrepancy. Identify any other cost estimates in the SAMA analyses that include contingency costs. Provide the impact on the SAMA evaluation if all contingent costs are included.

CERTIFICATE OF SERVICE I certify that on June 12, 2008, copies of the foregoing Riverkeeper, Inc.'s Supplemental Citation in Support of Admission of Contention EC-2 were served on the following by e-mail and first-class mail:

Lawrence G. McDade, Chair Robert D. Snook, Esq.

Atomic Safety and Licensing Board Panel Assistant Attorney General Atomic Safety and Licensing Board 55 Elm Street, P.O. Box 120 U.S. Nuclear Regulatory Commission Hartford, CT 06141-0120 Washington, D.C. 20555 By e-mail: Robert. Snooka),po.state.ct.us Also by e-mail: Lawrence.McDade(i)nrc.gPov Richard E. Wardwell Michael J. Delaney, V.P. - Energy Atomic Safety and Licensing Board New York City Econ. Development Corp.

U.S. Nuclear Regulatory Commission 110 William Street Washington, D.C. 20555 New York, NY 10038 Also by e-mail: Richard. Wardwellgnrc. gov Also by e-mail: mdelaneygnycedc.com John LeKay Martin J. O'Neill, Esq.

Heather Ellsworth Burns-DeMelo Kathryn M. Sutton, Esq.

Remy Chevalier Paul M. Bessette, Esq.

Bill Thomas Mauri T. Lemoncelli, Esq.

Belinda J. Jaques Morgan, Lewis & Bockius, LLP FUSE USA 1111 Pennsylvania Ave. N.W.

351 Dyckman Street Washington, D.C. 20004 Peekskill, NY 10566 martin.oneill@morganlewis.com Also by e-mail: fuse usagyahoo.com pbessetteDmorganlewis.com ksutton (,morganlewis.com Susan H. Shapiro, Esq.

Office of Commission Appellate Adjudication 21 Perlman Drive U.S. Nuclear Regulatory Commission Spring Valley, NY 10977 Washington, D.C. 20555 Also by e-mail: mbs@ourrocklandoffice.com Also by e-mail: OCAAMAILgnrc.gov John J. Sipos, Esq.

Sherwin E. Turk, Esq., Lloyd B. Subin, Esq.

Assistant Attorney General Beth N. Mizuno, Esq., David E. Roth, Esq.

Office of the New York Attorney General Jessica Bielecki, Esq., Marcia J. Simon, Esq.

for the State of New York Office of General Counsel The Capitol U.S. Nuclear Regulatory Commission Albany, New York 12224 Washington, D.C. 20555 Also by e-mail: John.Sipos(aoag.state.ny.us; sbt@nrc.gov; Marcia.simon,@nrc.gov; Jessica.bielecki canrc.gov; bnm2@nrc.gov; der@inrc. gov;

Office of the Secretary Rulemakings and Adjudications Staff U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Also by e-mail: HEARINGDOCKET@nrc.gov William C. Dennis, Esq.

Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Also by e-mail: wdennis2entergy.corn Stephen C. Filler, Board Member Hudson River Sloop Clearwater, Inc.

303 South Broadway, Suite 222 Tarrytown, NY 10591 Also by e-mail: sfiller@nylawline.com Manna Jo Greene Hudson River Sloop Clearwater, Inc.

112 Little Market Street Poughkeepsie, NY 12601 Also by e-mail: Mannajona)clearwater.org Justin D. Pruyne, Esq.

Assistant County Attorney, Litigation Bureau Of Counsel to Charlene M. Indelicato, Esq.

Westchester County Attorney 148 Martine Avenue, 6 th Floor White Plains, NY 10601 Also by e-mail: idp3@ westchestergov.com Joan Leary Matthews, Esq.

Senior Attorney for Special Projects New York State Department of Environmental Conservation 625 Broadway, 14th floor Albany, New York 12233-5500 By e-mail: ilmatthews(agw.dec. state.ny.us Zackary S. Kahn, Esq., Law Clerk Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Also by e-mail: Zachary.Kahn(ninrc.gov Thomas F. Wood, Esq.

Daniel Riesel, Esq.

Sive, Paget and Riesel, P.C.

460 Park Avenue New York, NY 10022 Also by e-mail: driesel~nsprlaw.comn I

Judge Kaye D. Lathrop 190 Cedar Lane East Ridgeway, CO 81432 Also by e-mail: Kaye.Lathrop cnrc.gov Nancy Burton 147 Cross Highway Redding Ridge, CT 06878 Also by e-mail: NancyBurtonCTgaol.com Elise N. Zoli, Esq.

Phillip Musegaas, Esq.

Goodwin Procter, LLP Victor Tafur, Esq.

53 State Street Riverkeeper, Inc.

Boston, MA 02109 828 South Broadway Also by e-mail: ezoli@ goodwinprocter.com Tarrytown, NY 10591 Marcia Carpentier, Esq., Law Clerk Janice A. Dean, Esq.

Atomic Safety and Licensing Board Assistant Attorney General Mail Stop: T-3 E2B Office of the Attorney General U.S. Nuclear Regulatory Commission 120 Broadway, 26th Floor Washington, D.C. 20555-0001 New York, NY 10271 Marcia.Carpentier a nrc.gov Also by e-mail: Janice.deanaioag.state.ny.us 2

Mylan L. Denerstein, Esq.

Executive Deputy Attorney General 120 Broadway, 25 Floor New York, NY 10271 Also by e-mail:

mvylan.denerstein(ioan. state.nv. us John L. Parker, Esq.

Regional Attorney, Region 3 New York State Department of Environmental Conservation 21 South Putt Corners New Paltz, NY 12561 Also by e-mail: i lparkeragw. dec.state.ny.us Diane Curran 3