BEntergy Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, N.Y. 10511-0249 Tel (914) 734-6700 Fred Dacimo Vice President License Renewal May 21, 2008 Indian Point Unit Nos. 2 and 3 Docket Nos. 50-247 & 50-286 NL-08-085 Mr. Andrew Feeney First Deputy, Director New York State Emergency Management Office 1220 Washington Avenue Public, Security. Building 22, Albany, New York 12226-2251
Subject:
Reference:
Indian Point Energy Center Siren System Far Field Acoustic Testing Report
- 1. Entergy letter (NL-08-026), Alert and Notification System Far Field Meas-urement Methodology, Fred DaCimo to Andr-ewFeeney, dated February 7, 2008
- 2. Entergy letter (NL-08-059), Alert and Notification System Final Design Report, Fred Dacimo to Andrew Feeney, dated April 28, 2008
Dear Mr. Feeney:
Enclosed for your review is the Far Field Acoustic Testing. Report for the Indian Point Energy Center (IPEC) Alert and Notification System sirens in enclosure 1. This submittal is, being provided in accordance with the IPEC siren project-schedule. The-Far Field Measurement Methodology was previously submitted by reference 1. is an Entergy matrix of open issues that FEMA has brought to my staff's attention post design report submission. Each open issue has been addressed as listed on the attached matrix.
Revised and additional sections of the design report previously submitted by reference 2 are provided in enclosure 3. The revised design report sections reflect final siren locations and the incorporation of the most recent far field acoustic measurements.
4_Ws
Docket Nos. 50-247 & 50-286 NL-08-085 Page 2 of 3 Should you have any questions regarding this matter, pleasecontact Mr. Michael J.
Slobodien, Director Emergency Planning, Entergy at (914) 272-3352.
Sinjesy yours, Fred R. Dacimo
.Vice President License Renewal Indian Point Energy center'
Docket Nos. 50-247 and 50-286 NL-08-085 Page 3 of 3 : Indian Point Energy Center Siren System Far Field Acoustic Testing Report, April 2008 : Matrix of FEMA Issues Post Design Report Submission : Revised/Additional Design Report Sections cc:
Document Control Desk (w/ Enclosure)
U.S. Nuclear. Regulatory Commission Mail Stop O-PI -17 Washington, DC 20555-0001 Mr. Samuel J. Collins (w/ Enclosure)
Regional Administrator, RegionI U.S. Nuc!ear, Regulatory Commission 475 Allendaleaý Road, King 'of Prussia,, Pennsylvania 19406-1415 Resident Inspector's Office (wI Enclosure)
Indian Point Unit Nos. 2 and 3 U.S. Nuclear Regulatory Commission Mr. Robert Kahler (w/ Enclosure)
Office of Nuclear Security and Incident Res Division of Preparedness and Response Licensing and Inspection Branch Nuclear, Regulatory Commission TWo White Flint North MS T3B46M i 1545 R6ckville Pike Rockville, MD 20852 Mr. Anthony Sutton (w/ Enclosure)
Commissioner Westchester County Department of Emergency Seryices 4 Dana Road Valhalla, New York 10595 Mr. Seamus Leary (w/ Enclosure)
Deputy. Commissioneri Orange County Department of Emergency Services 225 Main Street Goshen, New York 10924 Mr. Adam Stiebeling (w/ Enclosure)
- ponse Deputy Commissioner Putnam County Bureau of Emergency'Services 112 Old Route 6 Carmel, New York 10512 Ms.ý Rebecca S. Thomson (w/. 3 Enclosures)
REP Branch Chief, Federal: Emergency Management Agency Region 1..
26 Federal Plaza, 1 3th Floor, Suite 1337 New York, NY 10278-0002 Mr. Stephen Kempf, Jr. (w/ Enclosure)
Regional Administrator Federal Emergency Management Agency Region II 26 Federal Plaza New York, NY 10278 Mr. Daniel Greeley (w/ Enclosure)
Deputy Director Rockland County Fire and Emergency Services 35 Fireman's Memorial Drive Pomona, New York 10970
Docket Nos. 50-247 and 50-286 NL-08-085 Page 1 of 1 Indian Point Energy Center Siren System Far Field Acoustic Testing Report
Docket Nos. 50-247 and 50-286 NL-08-085 Page 1 of 1 Matrix of FEMA Issues Post Design Report Submission SOURCE OF OPEN ISSUE DISPOSITION OPEN ISSUE Email, Fuoto to Miele, Direction and distance Provided in the BRRC Far Field Acoustic'Testing Report (Enclosure 1).
5/2/08 from far field measurement' site to nearest siren Email, Fuoto to Grosjean, Error on Siren Map - 2 Corrected App. K map provided with this transmittal..:Revised sound contour 5/4/08 sirens labeled 115 map (Enclosure 3) replaces current map in Appendix K in the Design Report.
Email, Fuoto to Grosjean, Inquires about updated No additional data is available at this time.
5/5/08 reliability data post 9/17/07 (Design Report App. H)
Verbal, Gates to Grosjean, Requests RF propagation RF Propagation map provided with this transmittal. RF propagation map 5/6/08 map (Enclosure 3) to be inserted as new Appendix L in the Design Report.
Email, Fuoto to Grosjean, Requests spec sheet (cut Specification.sheet provided with'this transmittal. New specification sheet 5/6/08 sheet) on HPSS32/TH400.
(Enclosure3)to be added to Appendix F in the Design Report.
Carrying as open item in technical review.
Email, Fuoto to Specify barometric ATI has confirmed that the standard barometric pressure of 1013.25 hpa is Miele/Grosjean, 5/13/08 pressure used for used in the model. The barometric pressure at each far field measurement atmospheric absorption in location is identified in the BRRC Far Field Acoustic Testing Report the ATI model.
(Enclosure 1).
Email, Fuoto to Grosjean, Review Design Report Section 11 reviewed against NUREG-0654 and FEMA-REP-10 and revised 5/13/08 Section 11 against for clarity. Revised Section 11 (Enclosure 3). replaces currenrt Section 11 in NUREG-0654 and FEMA-the Design Report.
REP-10.
Email, Fuoto to Grosjean, Map in Section 3 does not EPZ Boundary on map in App. K did not match EPZ boundary on map in 5/15/08 agree with Map in Section 3. Corrected App. K map provided with-this transmittal. Revised Appendix K.
sound contour map (Enclosure 3) replaces current map in Appendix K in the Design Report.-
I Docket Nos. 50-247 & 50-286 NL-08-085 Page 1 of 1 Revised/Additional Design Report Sections Distribution of Revisions to IPEC Alert and Notification Design Report (May 21, 2008),
Sections/maps/tabs are to be. inserted into your-copy of-the IPEC Alert and Notification Design Report following the instructions listed below. The.TAB notation indicates. the.
section.
Inside Cover-Page (April, 2008)
'Inside Cover Page (May, 2008).
Taible-of Contents Table of.Contents, Revision' 1 TAB 7-Siren Characteristics Section 7 1 Section 7, Revision 1 TAB8'- GeneraltSystem Overview-Section 8 1: Section 8, Revision 1 TAB 11 - Acoustic Criteria of Siren System Section 11 Section 11, Revision 1 TAB 13-Verification of ATI Siren'AcousticComputer Model Section; 13 Section-13, Revision 1 TAB 14-Acoustic Testing and Analysis Section 14 Section 14, Revision 1 NEW.TABP-System Equipment Data
',-Insert-new HPSS32TBi-Directional Siren Spec
.-Sh-et iritoAppendix "
- TAB G. 7Sup'porting D-ocumentaitioin/References" '
AppendixG" Appendix G,. Rev sion -1 TAB K - Siren Coverage Within the EPZ of Indian Point Energy Center (Map)
Map.
iInsert revised Map NEW TAB L - RF Propagation Map Insert new Tab and new Map