{{#Wiki_filter:* Survey Unit Release Record Design # Survey Unit #(s) EP-PPH 109 Revision # Original PPH 109 Page 1 of 4 Description
- 1) Portions of Embedded Pipe (EP) Survey Unit PPH 109 that remain embedded in the building foundation walls meet the definition ofembedded pipe for Plum Brook Reactor Facility (PBRF). The portion of piping which transits in soil under and between the buildings does not meet the criteria for embedded piping. Upon demonstration of compliance with the release criteria (Sect. 5.2), the complete piping system will be grouted, including the portions embedded in the building structure that will remain embedded for any future reuse and those portions in the ground that can be released for unrestricted use.
- 2) EP PPH 109 is a Class 1, Group 1 survey unit as per the PBRF Final Status Survey Plan (FSSP) and Technical Basis Document (TBD)-06-004.
- 3) Multiple core bores were performed to remove sections of this pipe system to facilitate access for remediation and survey. Underlying soils were exposed by this activity. Isotopic analysis of soil samples taken after the completion of these activities indicate residual radioactivity at concentrations well below the release criteria.
- 4) Surveys in.EP PPH 109 were performed using a scintillation detector optimized to measure gamma energies representative of Co60
- Sample #EP 3-7 from Survey Request (SR)-13 was referenced for this decision.
- 5) Survey Instructions for this survey unit are incorporated into and performed in accordance with (IAW) the Babcock Services Incorporated (BSI)/LVS-002, Work Execution Package (WEP) 05-006. Survey instructions described in this document constitute "Special Methods" and the survey design used in the acquisition of survey measurements.
- 6) Instrument efficiency determinations are developed in accordance with the BSIILVS-002, WEP 05-006, these determinations are appropriate for the types of radiation involved and the media being surveyed.
Approval Signatures Date: FSS/Characterization Engineer FSS/Characterization Manager -//t~ A.Cas';/V~ Form CS-09/1 Rev 0
Revision # Original Page 2 of 4 Survey Unit: PPH 109 1.0 HistoryfDescription 1.1 The subject pipe is a 4, 6 and 8" drain line from PPH Room 1, PPH Room 2, PPH Room 3, PPH Room 4, and PPH Room 8 to the sump located in PPH Room 8. 1.2 EP PPH 109 consists of 4, 6 and 8" diameter piping that is approximately 209 feet in length. 2.0 Survey Design Information 2.1 EP PPH 109 was surveyed lAW Procedure #BSIILVS-002. 2.2 100% of the 4" pipe was accessible for survey. The accessible 4" pipe was surveyed by static measurement at one foot increments, for a total of 142 survey measurements. 2.3 Surface area for the 4" piping is 973 cm2 for each foot of piping, corresponding to a total 4" piping surface area of 138166 cm2 (13.9 m2) for the entire length of (approximately 142') of 4" piping. 2.4 100% of the 6" pipe was accessible for survey. The accessible 6" pipe was surveyed by static measurement at one foot increments, for a total of 47 survey measurements. 2.5 Surface area for the 6" piping is 1,459 cm2 for each foot of piping, corresponding to a total 6" piping surface area of 68573 cm2 (6.8 m2) for the entire length of (approximately 47') of 6" piping. 2.6 100% of the 8" pipe was accessible for survey. The accessible 8" pipe was surveyed by static measurement at one foot increments, for a total of 20 survey measurements. 2.7 Surface area for the 8" piping is 1,946 cm2 for each foot of piping, corresponding to a total 8" piping surface area of 38920 cm2 (3.9 m2) for the entire length of (approximately 20') of 8" piping. 2.8 The surface area ofPPH 109 is 24.6 m 2 3.0 Survey Unit Measurement LocationsfData 3.1 Pipe interior radiological survey forms are provided in Attachment 2 of this release record. 3.2 All floor drains, risers and cOlmecting piping to the main collection headers were removed by core bore during the remediation efforts with the exception of FD 8-1. Graphical presentation of these excavations in included in Attachment 3. 4.0 Survey Unit InvestigationslResults 4.1 None
'-----,----a_ FSS Design # EP PPH 109 IRevision # Original -I Page 3 of 4 Survey Unit: PPH 109 5.0 Data Assessment Results 5.1 Data assessment results are provided in the EP/Buried Pipe (BP) Survey Reports provided in Attachment I. 5.2 This survey unit was assessed as a building re-use scenario with all activity derived dose as a 100% C060 nuclide distribution. This is the most conservative DCGL for the facility (II,000 dpm/I 00cm2). 5.3 Four measurements observed in EP PPH 109 exceeded the Unity Rule as provided in Section 3.6.3 of the FSSP. Elevated Measurement Comparisons (EMC) and Elevated Measurement Tests were performed. EMC Unity for this survey unit is 0.130, EMT Unity is 0.550. The survey unit that is constituted by EP PPH 109 passes FSS. 5.4 The elevated measurements discussed in 5.3 above occurred in different rooms of the Primary Pump House. Additionally, PPH Room 4 may constitute more than one survey unit for structural survey unit dispositions. Individual data assessments were performed for each discreet section of piping to assist with future FSS efforts in the PPH. A composite assessment of all the piping bounded by EP PPH 109 was also performed. This composite assessment is reported in Section 5.7, the individual assessments may be reviewed in Attachment I. 5.5 DCGL's for the building reuse scenario are used to demonstrate compliance with the release criterion for this release record. The DCGL's for embedded pipe are not applied. 5.6 Background was not subtracted from the survey measurements. 5.7 Statistical Sununary Table Statistical Parameter Total Number of Survey Measurements Number of Measurements >MDC Number of Measurements Above 50% ofDCGL Number of Measurements Above DCGL Mean Median Standard Deviation Maximum Minimum 209 207 100 4 0.502 0.479 0.209 1.437 0.144
'--r-------a_ FSS Design # EP PPH 109 I Revision # Original l Page 4 of 4 Survey Unit: PPH 109 6.0 Docwnentation of evaluations pertaining to compliance with the unrestricted use limit of25 mrem/yr and dose contributions from Embedded Pipe and radionuclides contributing 10% in aggregate of the total dose for both structural scenarios and soils. 6.1 A review of the survey results has shown that the dose contribution for EP PPH 109 to be less than 25 mrern/yr. The dose contribution is estimated to be 12.6 rnrern/yr based on the average of the actual gross cOlmts measured. 7.0 Attachments - BSI EPIBP Survey Report - Pipe Interior Radiological Survey Form - Soil Sample Analysis - DQA Worksheet - EP PPH 109 Spreadsheet Disc
SECTION 7 ATTACHMENT 1 37 PAGES
IkilJJl* BSI EP/BP SURVEY REPORT Pipe ID PPH 109 Survey Location PRIMARY PUMP HOUSE Survey Date See Survey Sheets 2350-1 # 189094 / 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 4") 6"r 8" Detector Efficiency See Survey Sheets DCGL (dpmJ100cm2l 1.10E+04 Pipe A1ea Incorporated by Delector Efficiency lin cm2l See Survey Sheets Pipe Area Incorporated by 24.6 Field BKG (cpm) See Survey Sheets 5U1vev Dala fm' Routine Survey X Field MDCR (cpm) See Survey Sheets QA Survey Nominal MDC (dpmJ100cm2) See Survey Sheets Survey Measurement Results Total Number of Survey Measurements 209 Number of Measurements >MDC 207 Number of Measurements Above 50% DCGL 100 Number of Measurements Above DCGL 4 Mean 0.502 Median 0.479 Standard Deviation 0.209 Maximum 1.437 Minimum 0.144 Survey Technician(s) PHELPS Survey Unit Classification I 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-50 Area Factor/EMC Used Yes Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. ~ RP Engineer I Date BA/lf"~-/ /3~2~D? /
Unity 0.551 EMC Unity 0.479 0.431 0.359 I 0.719 ~ 0.431 ~ ..~ 0.035 0.719 0.599 0.287 0.407 0.287 0.311 0.240 0.671 0.551 0.527 0.359 0.599 0.815 1.389 0.335 0.311 0.359 0.335 0.240 0.359 0.431 0.503 0.144 0.287 0.335 0.287 0.671 0.383 0.216 0.036 0.527 0.287 0.407 0.623 0.599 0.934 1.437 PPH 109 4', 6", 8" Pipe
- z:
(J -Z ~ ~ I 0 (J
- z:
r:l. r:l.
- z:
(J Z- ~ N I 0 (J
- z:
r:l. r:l. ~... t: Q) E Q)... III I'D
- e Q) 1 2
3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 I I I gcpm I i 23 20 18 15 30 18 30 25 12 17 12 13 10 28 23 22 15 25 34 58 14 13 15 14 10 15 18 21 6 12 14 12 28 16 9 22 12 17 26 25 39 60 ncpm 23 20 18 15 30 18 30 25 12 17 12 13 10 28 23 22 15 25 34 58 14 13 15 14 10 15 18 21 6 12 14 12 28 16 9 22 12 17 26 25 39 60 TBD 06-004 Group 1 I I Co-50 activity Co-50 activity (total dpm) (dpml1OOcm 2) I 1 58,974 6,061 51,282 5,271 46,154 4,743 38,462 3,953 EMT Unity 0.551 0.479 - 0.431 '0.359 0.719 0.431 0.719 0.599 0.287 0.407 0.287 0.311 0.240 0.671 0.551 -e-
0.527 0.359 0.599 0.815 0.335 0.311 0.359 0.335 0.240 0.359 - 0.431 0.503 0.144 0.287 I---.--- 0.335 0.287 0.671 0.383 0.216 0.527 0.287 I-
0.407 0.623 I-- 0...:..599 0.934 f--. f 0.022 l 1--
e 0.024 76,923 46,154 76,923 64,103 30,769 43,590 30,769 33,333 25,641 71,795 58,974 56,410 38,462 64,103 87,179 148,718 35,897 33,333 38,462 35,897 25,641 38,462 46,154 53,846 15,385 30,769 35,897 30,769 71,795 41,026 23,077 56,410 30,769 43,590 66,667 64,103 100,000 153,846 7,906 4,743 7,906 6,588 3,162 4,480 3,162 3,426 2,635 7,379 6,061 5,798 3,953 6,588 8,960 15,284 3,689 3,426 3,953 3,689 2,635 3,953 4,743 5,534 1,581 3,162 3,689 3,162 7,379 4,216 2,372 5,798 3,162 4,480 6,852 6,588 10,277 15,812 1 of 6
PPH 109 4', 6", 8" Pipe TBD 06-004 Group 1 '1:t:.. I I Q) C I E I Co-60 activity Co-60 activity EMC ncpm Unity (total dpm) (dpm/100cm2) Unity I 23 58,974 6,061 0.551 26 66,667 6,852 0.623 14 35,897 3,689 0.335 25 64,103 6,588 0.599 22 56,410 5,798 0.527 58 148,718 15,284 1.389 0.035 42 107,692 11,068 1.006 0.025 36 92,308 9,487 0.862 35 89,744 9,223 0.838 _.0-23 58,974 6,061 0.551 37 94,872 9,750 0.886 12 30,769 3,162 I 0.287 19 48,718 5,007 0.455 6 15,385 1,581 0.144 26 66,667 6,852 0.623 38 97,436 10,014 0.910 16 41,026 4,216 0.383 13 33,333 3,426 0.311 17 43,590 4,480 0.407 14 35,897 3,689 0.335 22 56,410 5,798 0.527 I 23 58,974 6,061 0.551 24 61,538 6,325 0.575 19 48,718 5,007 0.455 EMT Q)... Igcpm Unity III III Q) 0.551 1 23 Z-0.623 2 26 0.335 3 14 'lll:t e-. 0.599 4 25 ~ I 0.527 5 22 7 58 (II) 0.018 0 8 42 (J 0.862 9 36 X 0.838 10 35
- n.
0.551 11 23
- n.
-J--- 1,2 37 0.886 - 1, 12 0.287 2 19 0.455 Z-0.144 3 6 ._- 0.623 4 26 'lll:t 0.910 5 38
N I 0.383 6 16 (II) 0.311 7 13 0 0.407 8 17 (J 0.335 9 14 X 0.527 10 22
- n.
0.551 11 23
- n.
0.575 I 12 24 13 19 0.455 2 of 6
PPH 109 4',6",8" Pipe ".'~:;.,.~' ~ .",'.'" ~.,,-.-::.... ~ .~,_. Z CD N I M 0 U J: D. D. -Z oqo ~ I oqo 0 U I a.
- a.
Z CD 'lI(" I "Il:t 0 U J: D. D. ~ l: Q) I I E... gcpmj Q) ncpm III cu Q) ~ 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 1 2 3 4 5 6 7 8 9 10 11 12 13 1:4 15 16 17 18 19 36 30 10 29 20 36 32 36 37 32 25 27 35 40 38 38 30 39 37 35 25 39 19 23 21 15 29 23 21 26 27 22 24 21 18 17 21 27 32 25 11 36 30 10 29 20 36 32 36 37 32 25 27 35 40 38 38 30 39 37 35 25 39 19 23 21 15 29 23 21 26 27 22 24 21 18 17 21 27 32 25 11 TBD 06-004 Group 1 I I Co-50 activity (total dpm) 116,129 96,774 32,258 93,548 64,516 116,129 103,226 116,129 119,355 103,226 80,645 87,097 112,903 129,032 122,581 122,581 96,774 125,806 119,355 112,903 80,645 125,806 48,718 58,974 53,846 38,462 74,359 58,974 53,846 66,667 87,097 70,968 77,419 67,742 58,065 54,839 67,742 87,097 103,226 80,645 35,484 Co-60 activity (dpm/100cm2) 7,959 6,633 2,211 6,412 4,422 Unity 0.724 EMC Unity 0.603 0.201 0.583 0.402 7,959 7,075 0.724 0.643 7,959 8,181 7,075 5,527 0.724 0.744 0.643 0.502 5,970 7,738 8,844 0.543 0.703 0804 8,402 8,402, 0.764 0.764 6,633 0.603 8,623 0.784 ~-- 8,181 0.744 7,738 0.703 5,527 8,623 5,007 6,061 5,534 0.502 0.784 0.455 0.551 0.503 3,953, 7,642 1 6,061 5,534 6,852 0.359 0.695 0,551 0.503 0.623 5,970 0.543 4,864 0.442 5,306 0.482 4,643 0.422 3,980 0.362 3,759, 0.342 4,643 0.422 5,970 0.543 7,075 5,527 2,432, 0.643 0.502 0.221 EMT Unity 0.724 ~- 0.603 0.201 0.583 0.402 0.724 0.643 0.724 1-0.744 I-- -- 0.643 0.502 0.543 0.703 0.804 0.764 f--.. _.-
0.764 0.603 0.784 0.744 0.703 ~ I--..._- 0.502 0.784 0.455 0.551 ~- 0.503 0.359 0.695 0.551 -~- 0.503 ~ 0.623 0.543 .e-
0.442 0.482 _. _ -. - ~ - 0.422 0.362 0.342 e-. 0.422 0.543 0.643 ~-- 0.502 0.221 3 of 6
PPH 109 4', 6", 8" Pipe TSO 06-004 Group 1 N I "ll:t 0 U
- I:
D. D. Z ~ M* ~ 0 (.) Z
- 0.
- 0.
Z CD M I "ll:t 0 U
- I:
0a. ~ I ... I l: Q) E I ~ gcpm
- J III IV
- e Q) I 1
17 2 15 3 22 4 14 5 13 6 41 8 30 9 26 10 20 11 30 12 23 13 22 14 24 15 22 16 36 17 20 18 15 19 19 1 20 2 14 3 12 4 24 5 16 6 28 7 19 8 23 9 19 10 23 11 15 12 9 13 13 14 19 15 1'3 16 24 17 14 18 13 19 15 20 19 21 30 22 13 I I I Co-50 activity I Co-50 activity ncpm Unity (total dpm) (dpm/100cm2) I I I I 17 43,590 4,480 0.407 15 38,462 3,953 0_359 22 56,410 5,798 0.527 14 35,897 3,689 0.335 13 33,333 3,426 0.311 41 105,128 10,805 0.982 30 76,923 7,906 0.719 26 66,667 6,852 0.623 20 51,282 5,271 0.479 30 76,923 7,906 0.719 23 58,974 6,061 0.551 0.527 24 61,538 6,325 22 56,410 5,798 0.575 22 56,410 5,798 0.527 36 92,308 9,487 I 0.862 20 51,282 5,271 I 0.479 15 38,462 3,953 0.359 19 48,718 5,007 0.455 20 51,282 5,271 0.479 14 35,897 3,689 0.335 12 30,769 3,162 0.287 0.575 16 41,026 4,216 24 61,538 6,325 0.383 28 71,795 7,379 0.671 19 48,718 5,007 0.455 23 58,974 6,061 0.551 19 61,290 4,201 0.382 23 74,194 5,085 0.462 15 48,387 3,316 0.301 9 29,032 1,990 0.181 13 41,935 2,874 0.261 19 61,290 4,201 I 0.382 13 41,935 2,874 I 0.261 24 77,419 5,306 0.482 14 45,161 3,095 0.281 13 41,935 2,874 0.261 15 48,387 3,316 0.301 19 61,290 4,201 0.382 30 96,774 6,633 0.603 13 41,935 2,874 0.261 EMC EMT Unity Unity 0.407 0_359 0.527 _. _. ~ 0.335 0.311 0.982 0.719 0.623 0.479 0.719 0.551 0.527 0.575 0.527 0.862 0.479 0.359 --._--._-- 0.455 0.479
0.335 -f-- 0.287 0.575 0.383 0.671 0.455 0.551 0.382 0.462
0.301 0.181
0.261 0.382
0.261 0.482 0.281 t-----
0.261 - f---
0.301 0.382 0.603 --- ~- 0.261 4 of 6
PPH 109 4', 6", 8" Pipe TBD 06-004 Group 1 -Z CO M I ~ 0 U J: Q. Q. "I'"" I 00 0 t) Z a.
- a.
N I co 0 u
- I:
- a.
- a.
- tt:...
~ I G) I E EMC EMT G)..
- , IgCpfn I ncpm Unity Unity III cu G) 23 24 24 I
I I Co-50 activity Co-50 activity Unity (total dpm) (dpm/100cm2) I I 82,759 4,253 0,387 75,862 3,898 0,354 72,414 3,721 0.338 193,103 9,923 0.902 151,724 7,797 0.709 93,103 4,784 0.435 93,103 4,784 0.435 189,655 9,746 0.886 120,690 6,202 0.564 120,690 6,202 0.564 72,414 3,721 0.338 82,759 4,253 0.387 0_-_- 62,069 3,190 0.290 55,172 2,835 0.258 68,966 3,544 I 0.322 79,310 4,076 0.371 68,966 3,544 0.322 41,379 2,126 0.193 58,621 3,01 1 2 0.274 58,621 3,012 0.274 56,410 5,798 0.527 58,974 6,061 0.551 69,231 7,115 0.647 51,282 5,271 0.479 28,205 2,899 0.264 38,462 3,953 0.359 41,026 4,216 0.383 33,333 3,426 0.311 41,026 4,216 0.383 35,897 3,689 0.335 46,154 4,743 0.431 0.387 24 22 22 0.354 25 21 21 0.338
26 56 56 0.902 27 44 44 0.709 28 27 27 0.435 29 27 27 0.435 0.886 30 55 55 31 35 35 0.564 I--
0.564 32 35 35 33 21 21 0.338 0.387 34 24 24 0.290 35 18 18
0.258 36 16 16 0.322 37 20 20 0.371 38 23 23 0.322 39 20 20 0.193 40 12 12 1------.
41 17 17 0.274 42 17 17 0.274 0.527 1 22 22 ~ 0.551 2 23 23 0.647 3 27 27 0.479 4 20 20 I---- ---
0.264 5 11 11 ...---- t--
0.359 1 16 16 6 15 15 0.383 0.311 2 13 13 0.383 3 16 16 I-0.335 4 14 14 0.431 5 18 18 5 of 6
PPH 109 4',6",8" Pipe ~ I I c: Q) E Q)... gcpm I
- J lQ III I I
~ 1 24 2 28 3 17 4 30 5 16 6 22 7 26 8 18 9 18 C") 10 20 I 11 10 12 12 CO 0 13 21 14 21 (J J: 15 26 tl. tl. 16 35 17 11 18 17 19 24 20 21 21 21 22 16 23 28 24 12 25 12 1 21 ~* 2 15 CO 3 17 4 12 C U. 5 30 6 25 -- ---L -t J .~ TBD 06-004 Group 1 i I Co-GO activity Co-GO activity EMC EMT Unity (total dpm) (dpm/100cm2) Unity Unity 1 i 61,538 6,325 0.575 0.575 71,795 7,379 0.671 0.671 43,590 4,480 00407 00407 ---~ 76,923 7,906 0.719 0.719 41,026 4,216 0.383 0.383 -~-_..~- - 56,410 5,798 0.527 0.527 66,667 6,852 1 0.623 0.623 -~ 46,154 4,743 I 00431 OA31 46,154 4,743, 00431 OA31 51,282 5,271 OA79 OA79 25,641 2,635 0.240 0.240 30,769 3,162 0.287 0.287 53,846 5,534 0.503 0.503 53,846 5,534 0.503 0.503 66,667 6,852 0623 0.623 .~_..~-. _. 89,744 9,223 0.838 0.838 28,205 2,899 0.264 0.264 '- 43,590 4,480 00407 OA07 61,538 6,325 0.575 0.575 53,846 5,534 0.503 0.503 -~ -_. 53,846 5,534 0.503 0.503 41,026 4,216 0.383 0.383 ~.- 71,795 7,379 0.671 0.671 30,769 3,162 0.287 0.287 -0 _._ 30,769 3,162 0.287 0.287 53,846 5,534 0.503 0.503 38,462 3,953 0.359 0.359 43,590 4,480 OA07 0.407 30,769 3,162 0.287 0.287 76,923 7,906 0.719 0.719 64,103 6,588 0.599 0.599 ___--I-5,346 0.130 0.550 EMC EMT MEAN 0502 Unity Unity -L MEDIAN OA79 STD DEV 0.209 +~- MAX 1.437 - -+ MIN 0.144 ncpm 24 28 17 30 16 22 26 18 18 20 110 12 21 21 26 35 11 17 24 21 21 16 28 12 12 21 15 17 12 30 25 6 of 6
BSI EP/BP SURVEY REPORT Pipe ID PPH 109 Survey Location PPH RM 1, CO-1 Survey Date S;o" Survey Sheets 2350-1 # 203438 Survey Time See urvey Sheets Detector-Sled # LVS1-101 Pipe Size 4" Detector Efficiency 0.00039 DCGL fdpml1 OOcm2 I 1.10E+04 "". Ior.a Ineo'p"....d by 0'<1 EI!IdIJn<y (lo ern21 973 PIp. Ana In[;Orporal:ed by SUrv..~* 19 Field BKG (epml See Survey Sheets D..~(m'l Routine Survey X Field MDCRlel>fT\\1 See Survey Sheets QA Survey Nominal MDe I~OU m2/ 2366 Survey Measurement Results Total Number of Survey Measurements 20 Number of Measurements >MDC 20 Number of Measurements Above 50% DCGL 10 Number of Measurements Above DCGL 1 Mean 0537 Median 0503 Standard Deviation 0258 Maximum 1389 Minimum 0240 PHELPS Survey Technician(s) Survey Unit ClasSification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-GO Area Factor/EMC Used Yes Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED RP Engineer I Date Ij1AkJ /3 D r /
ACTIVITY WORKSHEET CO-1 4 INCH e 'It ~ C QI E QI...
- I l'3 QI gcpm ncpm 1
23 23 2 20 20 3 18 18 4 15 15 5 30 30 7 18 18 8 30 30 9 25 25 10 12 12 11 17 17 12 12 12 13 13 13 14 10 10 15 28 28 16 23 23 17 22 22 18 15 15 19 25 25 20 34 34 21 58 58 Co~O activity (tot:1' dprn) 58,974 51,282 46,154 38,462 76,923 46,154 76,923 64,103 30.769 43,590 30,769 33,333 25,641 71,795 58.974 56,410 38.462 64,103 87,179 148 718 C0-60 activity (dpm/100cm2) Unity EMC Unity EMT Unity 6,061 0551 0.035 0.551 0.479 0.431 0359 0719 0.431 0719 0.599 0.287 0.407 0.287 0.311 0240 0.671 0.551 0.527 0.359 0.599 0.815 5,271 0479 4,743 0.431 3,953 0.359 7,906 0.719 4,743 0.431 7,906 0719 6,588 0,599 3,162 0.287 4480 0407 3,162 0.287 3,426 0.311 2.635 0240 7,379 0.671 6,061 0.551 5,798 0.527 3.953 0359 6,588 0.599 8,960 0815 15.284 1389 3.750 0.035 0.518 MEAN 0.537 EMC Unity EMT Unity MEDIAN 0503 STD DEV 0.258 MAX 1.389 MIN 0.240 0.026
I ,~ ,.~~ BSt EP/B su EY REPORT PPH 109 Survey Location PPH RM 2. CO-2 Survey Date Pipe 10 s.... survl!)l ShelMS 2350-1 # 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 4" Detector Efficiency 000039 1~ 10E+04 ""'. AI.a lncmT>c>r"od by Dolo""", E1lIolot'lC'/ fin cm2' 973 DCGL (dpmNlXIcm2J P\\pe Ant" IncorpOl"at"d l:t)' SUTVtfY 2.1 See Survey Sheets Field BKG I,pml Oat,lm'\\ Routine Survey X See Survey Sheets QA Survey Field MDCR (epm) Nominal MDC (~IJO<.m21 2.366 Survey Measurement Results Total Number of Survey Measurements 22 Number of Measurements >MDC 21 Number of Measurements Above 50/0 DCGL 7 Number of Measurements Above DCGL 1 Mean 0455 Median 0.359 Standard Deviation 0.282 Maximum 1437 Minimum 0144 PHELPS Survey Tecflnician(s) Survey unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-50 Area Factor/EMC Used Yes Pas /Fail FSS Pass MREMfYR Contribution <25 COMMENTS ACTIVITY VALUES NOT BACKGROUND CORRE TED RP Engineer I Date ,l!JJJ/ !5 ---2 -D g
ACTIVITY WORKSHEET CO-2 4 INCH
- u:-
c cu E ~
- l III cv cu
- i:
gcprn ncprn 1 14 14 2 13 13 3 15 15 4 14 14 5 10 10 7 15 15 8 18 18 9 21 21 10 6 6 11 12 12 12 14 14 13 12 12 14 28 28 15 16 16 16 9 9 17 22 22 18 12 12 19 17 17 20 26 26 21 25 25 22 39 39 23 60 60 Co-50 activity (total dpm) 35,897 33,333 38,462 35,897 25,641 38,462 46,154 53,846 15,385 30,769 35,897 30,769 71,795 41,026 23,077 56,410 30,769 43,590 66,667 64,103 100,000 153,846 Co-60 activity (dpmI100cm2) Unity EMC Unity EMT Unity 3,689 0335 0.036 0.335 0.311 0.359 0.335 0.240 0359 0.431 0.503 0144 0.287 0.335 0.287 0.671 0.383 0.216 0.527 0.287 0,407 0623 0.599 0.934 3,426 0.311 3,953 0359 3,689 0.335 2,635 0.240 3,953 0359 4,743 OA31 5,534 0.503 1,581 0.144 3,162 0.287 3,689 0335 3,162 0287 7,379 0.671 4,216 0.383 2,372 0.216 5,798 0.527 3,162 0.287 4,480 OA07 6,852 0.623 6,588 0599 10,277 0.934 15,812 1,437 2,676 0.036 0.408 MEAN 0,455 EMC Unity EMT Unity MEDIAN 0.359 STD DEV 0.282 MAX 1,437 MIN 0144 0030
IiJDJ!t BSI EP/BP SURVEY REPORT Pipe ID PPH 109 Survey Location PPH RM 3, CO 3-1 Survey Date See Survey Sheets 2350-1 # 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 4" Detector Efficiency 0.00039 DCGL (dpmJl00cm2) 1.10E+04 Pipe Area Incorporated by Detector Efficiency (in cm2) 973 Pipe Area Incorporated by Survey Data m 2 11 Field BKG (cpm) See Survey Sheets Routine Survey X Field MDCR (cpm) See Survey Sheets QA Survey Nominal MDC (dpmJl00cml) 2,366 Survey Measurement Results Total Number of Survey Measurements 11 Number of Measurements >MDC 11 Number of Measurements Above 50% DCGL 10 Number of Measurements Above DCGL 2 Mean 0.743 Median 0.623 Standard Deviation 0.292 Maximum 1.389 Minimum 0.335 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used Yes Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED RP Engineer I Date ~ / ~-2 -u ES
ACTIVITY WORKSHEET CO 3*1 41N ~- c: II) E II)..
- l III IV II)
~ gcpm ncpm 1 23 23 2 26 26 3 14 14 4 25 25 5 22 22 7 58 58 8 42 42 9 36 36 10 35 35 11 23 23 12 37 37 Co-50 activity (total dpm) 58,974 66,667 35,897 64,103 56,410 148,718 107,692 92,308 89,744 58,974 94,872 Co-50 activity (dpmf100cm2) Unity EMC Unity EMT Unity 6,061 0.551 0.035 0.025 0.551 0.623 0.335 0.599 0.527 0.862 0.838 0.551 0.886 6,852 0.623 3,689 0.335 6,588 0.599 5,798 0.527 15,284 1.389 11,068 1.006 9,487 0.862 9,223 0.838 6,061 0.551 9,750 0886 4,885 0.060 0.660 MEAN 0.743 EMC Unity EMT Unity MEDIAN 0.623 STD DEV 0.292 MAX 1.389 MIN 0.335 0.019
Ikil:o!it BSI EP/BP SURVEY REPORT Pipe 10 PPH 109 Survey Location PPH RM 3, CO 3-2 4 INCH Survey Date See Survey Sheets 2350-1 # 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 4" Detector Efficiency 0.00039 DCGL (dpm/10Ocm2) 1.10E+04 Pipe Area Incorporated by Detector Efficiency lin cm2) 973 Pipe Area Incorporated bV Survey Data Im'l 1.3 Field BKG (cpm) See Survey Sheets Routine Survey X Field MDCR (cpm) See Survey Sheets QA Survey Nominal MDC (dpm/10Ocm2) 2,366 Survey Measurement Results Total Number of Survey Measurements 13 Number of Measurements >MDC 12 Number of Measurements Above 50% DCGL 5 Number of Measurements Above DCGL 0 Mean 0.459 Median 0.455 Standard Deviation 0.190 Maximum 0.910 Minimum 0.144 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. g RP Engineer I Date ~;& 0 ")2S?" l
ACTIVITY WORKSHEET CO 3-2 41N 'It... l: Q) E Q)... ~ l/lca Q)
- E 1
2 3 4 5 6 7 8 9 10 11 12 13 gcpm 12 19 6 26 38 16 13 17 14 22 23 24 19 ncpm 12 19 6 26 38 16 13 17 14 22 23 24 19 Co-50 activity (total dpm) 30,769 48,718 15,385 66,667 97,436 41,026 33,333 43,590 35,897 56,410 58,974 61,538 48,718 Co-50 activity (dpm/100cm2) Unity EMC Unity EMT Unity 3,162 0287 5,007 0455 1,581 0.144 6,852 0.623 10,014 0.910 4,216 0.383 3,426 0.311 4,480 0407 3,689 0.335 5,798 0.527 6,061 0.551 6,325 0.575 5,007 0455 MEAN 0459 MEDIAN 0.455 STD DEV 0.190 MAX 0910 MIN 0.144
Ii1K:Ili BSI EP/BP SURVEY REPORT Pipe ID PPH 109 Survey Location PPH RM 3, CO 3-2 6 INCH Survey Date See Survey Sheets 2350-1 # 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 6" Detector Efficiency 0.00031 DCGL (dpm/100cITl2) 1.10E+04 Pipe Area Incorporated by Detector Efficiency (in cm2) 1459 Pipe Area Incorporated by Survey Data /ITl'1 3.2 Field BKG (CPlTl) See Survey Sheets Routine Survey X Field MDCR(cpm) See Survey Sheets QA Survey Nominal MDC (dpm/100clTl2) 1,985 Survey Measurement Results Total Number of Survey Measurements 22 Number of Measurements >MDC 22 Number of Measurements Above 50% DCGL 20 Number of Measurements Above DCGL 0 Mean 0.645 Median 0.703 Standard Deviation 0.147 Maximum 0.804 Minimum 0201 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. A~ j, -, ~() iJ g RP Engineer I Date ~/ /.5-Z
ACTIVITY WORKSHEET CO 3-2 61N ~... t: QI E QI...
- l UI nI QI 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 gcpm 36 30 10 29 20 36 32 36 37 32 25 27 35 40 38 38 30 39 37 35 25 39 ncpm 36 30 10 29 20 36 32 36 37 32 25 27 35 40 38 38 30 39 37 35 25 39 Co-GO activity (total dpm) 116,129 96,774 32,258 93,548 64,516 116,129 103,226 116,129 119,355 103,226 80,645 87,097 112,903 129,032 122,581 122,581 96,774 125,806 119,355 112,903 80,645 125,806 Co-GO activity (dpm/100cm2)
Unity EMC Unity EMT Unity 7,959 0.724 6,633 0.603 2,211 0.201 6,412 0.583 4,422 0.402 7,959 0.724 7,075 0.643 7,959 0.724 8,181 0.744 7,075 0.643 5,527 0.502 5,970 0.543 7,738 0.703 8,844 0.804 8,402 0.764 8,402 0.764 6,633 0.603 8,623 0.784 8,181 0.744 7,738 0.703 5,527 0.502 8,623 0.784 MEAN 0645 EMC Unity EMT Unity MEDIAN 0.703 STD DEV 0.147 MAX 0.804 MIN 0.201
Iktx:tJtt BSI EP/BP SURVEY REPORT PipelD PPH 109 Survey Location PPH RM 4, CO 4-1 4 INCH Surv~y Date See Survey Sheets 2350-1 # 189094 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 4" Detector Efficiency 0.00039 DCGL (dpm/l00cm2) 1.10E+04 Pipe Area Incorporated by Detector Efficiency (in cm2) 973 Pipe Area Incorporated by Survev Data 1m') 0.8 Field BKG (cpm) See Survey Sheets Routine Survey X Field MDCR (cpm) See Survey Sheets QA Survey Nominal MDC (dpm/l00cm21 2,366 Survey Measurement Results Total Number of Survey Measurements 8 Number of Measurements >MDC 8 Number of Measurements Above 50% DCGL 6 Number of Measurements Above DCGL 0 Mean 0.530 Median 0.527 Standard Deviation 0.102 Maximum 0.695 Minimum 0.359 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. g-RP Engineer I Date dJ--Jrd/ /J-Z-j)
ACTIVITY WORKSHEET CO 4-1 41N ~- c: Q) E Co-50 activity Q) gcprn ncprn
- l (total dpm)
III IV Q) ~ 1 19 19 48,718 2 23 23 58,974 3 21 21 53,846 4 15 15 38,462 5 29 29 74,359 6 23 23 58,974 7 21 21 53,846 8 26 26 66,667 Co-50 activity (dpm/100cm2) Unity EMC Unity EMT Unity 5.007 0.455 6,061 0.551 5,534 0.503 3,953 0.359 7,642 0.695 6,061 0.551 5,534 0.503 6,852 0.623 MEAN 0.530 MEDIAN 0.527 STD DEV 0.102 MAX 0.695 MIN 0.359
!ktlJJ!.t BSI EP/BP SURVEY REPORT Pipe ID PPH 109 Survey Location PPH RM 4, CO 4-1 6 INCH Survey Date See Survey Sheets 2350-1 # 189094 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 6" Detector Efficiency 000031 DCGL (dpmll00cm2) 110E+04 Pipe Area IncorpofBled bV Defector Efficiency fin cm2) 1459 Pipe Area Incorporated by Survey Data Im'l 1.6 Field BKG (cpm) See Survey Sheets Routine Survey X Field MDCR (cpm) See Survey Sheets QA Survey Nominal MDC (dpmJ100cm') 1,985 Survey Measurement Results Total Number of Survey Measurements 11 Number of Measurements >MDC 11 Number of Measurements Above 50% DCGL 4 Number of Measurements Above DCGL 0 Mean 0.448 Median 0.442 Standard Deviation 0.115 Maximum 0643 Minimum 0.221 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS ACTIVITY VALUES NOT BACKGROUND CORRECTED /1 RP Engineer I Date iIJ~JLf/ 3~2 - D~
ACTIVITY WORKSHEET CO 4-1 61N 'It: 'E CII E CII
- J 1/1 CII "'
- E 9
10 11 12 13 14 15 16 17 18 19 gcpm 27 22 24 21 18 17 21 27 32 25 11 ncpm 27 22 24 21 18 17 21 27 32 25 11 Co-60 aclivity (lolal dpm) 87,097 70,968 77,419 67,742 58,065 54,839 67,742 87,097 103,226 80,645 35,484 Co-GO aclivity (dpm/100cm2) Unity EMC Unity EMT Unity 5,970 0.543 4,864 0.442 5,306 0.482 4,643 0.422 3,980 0.362 3,759 0.342 4,643 0422 5,970 0543 7,075 0.643 5,527 0502 2,432 0.221 MEAN 0448 EMC Unity EMT Unity MEDIAN 0.442 STD DEV 0.115 MAX 0.643 MIN 0.221
lkiJct1J BSI EP/BP SURVEY REPORT Pipe 10 PPH 109 Survey Location PPH RM 4, CO 4-2 Survey Date See Survey Sheets 2350-1 # 189094 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 4" Detector Efficiency 0.00039 DCGL (dpmll00cm2) 1.10E+04 Pipe Area Incorporated by Detector Efficteocy (In cm2) 973 Pipe Area Incorporated by Survey Data 1m'1 1.8 Field BKG (cpm) See Survey Sheets Routine Survey X Field MDCR(cpm) See Survey Sheets QA Survey Nominal MDC Idpmll00cm2) 2,366 Survey Measurement Results Total Number of Survey Measurements 18 Number of Measurements >MDC 18 Number of Measurements Above 50% DCGL 10 Number of Measurements Above DCGL 0 Mean 0.544 Median 0527 Standard Deviation 0.182 Maximum 0.982 Minimum 0.311 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. RP Engineer I Date ~
- ~k~/.3-2-1)
ACTIVITY WORKSHEET CO 4-2 ~ l: Ql E Ql... j III IV Ql ~ 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 gcpm 17 15 22 14 13 41 30 26 20 30 23 22 24 22 36 20 15 19 ncpm 17 15 22 14 13 41 30 26 20 30 23 22 24 22 36 20 15 19 Co-GO activity (total dpm) 43,590 38,462 56,410 35,897 33,333 105,128 76,923 66,667 51,282 76,923 58,974 56,410 61,538 56,410 92,308 51,282 38,462 48,718 Co-GO activity (dpm/100cm2) Unity EMC Unity EMT Unity 4,480 0.407 3,953 0.359 5,798 0.527 3,689 0335 3,426 0.311 10,805 0.982 7,906 0.719 6,852 0.623 5,271 0.479 7,906 0.719 6,061 0.551 5,798 0.527 6,325 0.575 5,798 0.527 9,487 0.862 5,271 0479 3,953 0.359 5,007 0455 MEAN 0.544 MEDIAN 0.527 STD DEV 0182 MAX 0.982 MIN 0.311
1ltl1Jtt BSI EP/BP SURVEY REPORT Survey Location PPH RM 4, CO 4-3 4 INCH Survey Date Pipe ID PPH 109 See Survey Sheets 2350-1 # 203438 See Survey Sheets Survey Time Detector-Sled # LVS1-101 4" Pipe Size Detector Efficiency 0.00039 Pipe Area Incorporated by Detector Efficiency (in cm2) 1.10E+04 DCGL (dpm/l00cm2) 973 Pipe Area Inc orporated by 0.8 See Survey Sheets Field BKG (cpm) Survev Data Im'l Routine Survey X Field MDCR (cpml See Survey Sheets QA Survey 2,366 Nominal MDC (dpm/l00cm2) Survey Measurement Results Total Number of Survey Measurements 8 Number of Measurements >MDC 8 Number of Measurements Above 50% DCGL 3 Number of Measurements Above DCGL 0 Mean 0.467 Median 0.467 Standard Deviation 0.129 Maximum 0.671 Minimum 0.287 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. z-fJt-RP Engineer I Date 3 /ttW/
ACTIVITY WORKSHEET CO 4-3 41N ~- l:: G> E Co-GO activity G>.. gcpm ncpm (total dpm)
- l 1/1 CI:l G>
- E 1
20 20 51,282 2 14 14 35,897 3 12 12 30,769 4 24 24 61,538 5 16 16 41,026 6 28 28 71,795 7 19 19 48,718 8 23 23 58,974 Co-GO activity (dpm/1 OOcm2) Unity EMC Unity EMT Unity 5,271 0.479 3,689 0.335 3,162 0.287 6,325 0.575 4,216 0.383 7,379 0.671 5,007 0.455 6,061 0.551 MEAN 0.467 MEDIAN 0.467 STD DEV 0.129 MAX 0.671 MIN 0.287
Ii1DJtJ BSI EP/BP SURVEY REPORT PipelD PPH 109 Survey Location PPH RM 4, CO 4-3 6 INCH Survey Date See Survey SheelS 2350-1 # 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 6" Detector Efficiency 0.00031 DCGL (dpm/100cm2) 1.10E+04 Pipe Area Incorporated by Detector EffK:iency (in cm2) 1459 Pipe Area Incorporated by Survev Data Im'l 2.0 Field BKG (cpm) See Survey Sheets Routine Survey X Field MDCR(cpm) See Survey Sheets QA Survey Nominal MDC (dpm/100cm2) 1,985 Survey Measurement Results Total Number of Survey Measurements 14 Number of Measurements >MDC 14 Number of Measurements Above 50% DCGL 1 Number of Measurements Above DCGL 0 Mean 0.343 Median 0.301 Standard Deviation 0.113 Maximum 0.603 Minimum 0.181 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREM/YR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. ,;§d;~LJ /6-Z-De RP Engineer I Date /~ ~ftC)J'---
ACTIVITY WORKSHEET CO 4-3 61N ~... C Gl E Gl
- l VI cu Gl
~ 9 10 11 12 13 14 15 16 17 18 19 20 21 22 gcprn 19 23 15 9 13 19 13 24 14 13 15 19 30 13 ncprn 19 23 15 9 13 19 13 24 14 13 15 19 30 13 Co-50 activity (total dpm) 61,290 74,194 48,387 29,032 41,935 61,290 41,935 77,419 45,161 41,935 48,387 61,290 96,774 41,935 Co-50 activity (dpm/100cm2) Unity EMC Unity EMT Unity 4,201 0.382 5,085 0.462 3,316 0.301 1,990 0.181 2,874 0.261 4,201 0382 2,874 0.261 5,306 0.482 3,095 0.281 2,874 0.261 3,316 0.301 4,201 0.382 6,633 0.603 2,874 0.261 MEAN 0.343 EMC Unity EMT Unity MEDIAN 0.301 STD DEV 0.113 MAX 0.603 MIN 0.181
Ii1JcIJtj BSI EP/BP SURVEY REPORT Survey Location PPH RM 4, CO 4-3 8 INCH Survey Date Pipe 10 PPH 109 See Survey Sheets 2350-1 # 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 8" Detector Efficiency 0.00029 DCGL Idpm/100cm21 Pipe Area Incorporated by Detector Efficiency (in cm2) 1.10E+04 1946 Pipe Area Incorporated by 3.9 Field BKG (cpm) See Survey Sheets Survev Data m 2 Routine Survey X See Survey Sheets QA Survey Field MDCRCcpmJ Nominal MDC (dpmI100cm2) 1,591 Survey Measurement Results Total Number of Survey Measurements 20 Number of Measurements >MDC 20 Number of Measurements Above 50% DCGL 5 Number of Measurements Above DCGL 0 Mean 0.430 Median 0.362 Standard Deviation 0.199 Maximum 0.902 Minimum 0.193 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. Z-f}~ RP Engineer I Date ~/d
ACTIVITY WORKSHEET CO 4-3 81N
- t
- -
c: III E III...
- l gcpm ncpm C0-60 activity (total dpm) 1/1 III QI 23 24 24 82,759 24 22 22 75,862 25 21 21 72,414 26 56 56 193,103 27 44 44 151,724 28 27 27 93,103 29 27 27 93,103 30 55 55 189,655 31 35 35 120,690 32 35 35 120,690 33 21 21 72,414 34 24 24 82,759 35 18 18 62,069 36 16 16 55,172 37 20 20 68,966 38 23 23 79,310 39 20 20 68,966 40 12 12 41,379 41 17 17 58,621 42 17 17 58,621 Co-50 activity (dpm/100cm2)
Unity EMC Unity EMT Unity 4,253 0387 3,898 0.354 3,721 0.338 9,923 0.902 7,797 0.709 4,784 0.435 4,784 0.435 9,746 0.886 6,202 0.564 6,202 0.564 3,721 0338 4,253 0.387 3,190 0290 2,835 0258 3,544 0.322 4,076 0.371 3,544 0.322 2,126 0.193 3,012 0274 3,012 0274 MEAN 0.430 EMC Unity EMT Unity MEDIAN 0.362 STD DEV 0.199 MAX 0.902 MIN 0.193
IkilJJ!* BSI EP/BP SURVEY REPORT PPH RM 8, CO 8-1 Survey Date PPH 109 Survey Location Pipe 10 See Survey Sheets 2350-1 # 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 4" Detector Efficiency 0.00039 DCGL (dpm/100cm2) Pipe Area Incorporated by Detector Efficiency (in cm2) 1.10E+04 973 Pipe Area Incorporated by 0.6 Field BKG (cpm) See Survey Sheets Survev Data Im'l Routine Survey X See Survey Sheets QA Survey Field MDCR (cpm) Nominal MDC (dpml100cm2) 2,366 Survey Measurement Results Total Number of Survey Measurements 6 Number of Measurements >MDC 6 Number of Measurements Above 50% DCGL 3 Number of Measurements Above DCGL 0 Mean 0.471 Median 0.503 Standard Deviation 0.139 Maximum 0.647 Minimum 0.264 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. RP Engineer I Date
- ulrzS/
/~- z-ZJg
ACTIVITY WORKSHEET CO 8-1 c:: CI> E CI>...
- l l/)
nl CI> 1 gcpm 22 ncpm 22 Co-GO activity (total dpm) 56,410 2 23 23 58,974 3 27 27 69,231 4 5 6 20 11 15 20 11 15 51,282 28,205 38,462 Co-GO activity (dpm/100cm2) Unity EMC Unity EMT Unity 5,798 0.527 6,061 0.551 7,115 0.647 5,271 0.479 2,899 0264 3,953 0.359 MEAN 0.471 MEDIAN 0.503 STD DEV 0.139 MAX 0.647 MIN 0.264
llJDJ.t BSI EP/BP SURVEY REPORT Pipe 10 PPH 109 Survey Location PPH RM 8, CO 8-2 Survey Date See Survey Sheets 2350-1 # 203438 Survey Time See SUNey Sheets Detector-Sled # LVS1-101 Pipe Size 4" Detector Efficiency 0.00039 DCGL (dpm/l00cm2) 1.10E+04 Pipe Area Incorporated by Detector Efficiency fin cm2) 973 Pipe Area Incorporated by Survey Data 1m'. 0.5 Field BKG (cpm) See SUNey Sheets Routine SUNey X Field MDCR (cpm) See SUNey Sheets QA SUNey Nominal MOC (dpm/100cm2) 2,366 SUNey Measurement Results Total Number of SUNey Measurements 5 Number of Measurements >MDC 5 Number of Measurements Above 50% DCGL 0 Number of Measurements Above DCGL 0 Mean 0.369 Median 0.383 Standard Deviation 0.047 Maximum 0.431 Minimum 0.311 PHELPS SUNey Technician(s) SUNey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED RP Engineer I Date A[w/d~ Z - D g-
ACTIVITY WORKSHEET CO 8-2
- u:...
c:: QI E QI ~ ~ VI III QI ~ 1 gcpm 16 2 13 3 4 5 16 14 18 Co-GO activity Co-50 activity ncpm Unity EMC Unity EMT Unity (total dpm) (dpm/100cm2) 16 41,026 4,216 0.383 13 33,333 3,426 0.311 16 41,026 4,216 0383 14 35,897 3.689 0.335 18 46,154 4,743 0.431 MEAN 0.369 MEDIAN 0.383 STD DEV 0.047 MAX 0.431 MIN 0.311
!ktl:tJtt BSI EP/BP SURVEY REPORT Pipe 10 PPH 109 Survey Location PPH RM 8, CO 8-3 Survey Date See Survey SheelS 2350-1 # 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 Pipe Size 4" Detector Efficiency 0.00039 DCGL (dpm/l00cm2) 1.10E+04 Pipe Area Incorporated by Detector Efficiency (in cm2) 973 Pipe Area Incorporated by Survey Data 1m', 2.4 Field BKG (cpm) See Survey Sheets Routine Survey X Field MDCR (cpm) See Survey Sheets QA Survey Nominal MDC (dpm/l00cm2) 2,366 Survey Measurement Results Total Number of Survey Measurements 25 Number of Measurements >MDC 25 Number of Measurements Above 50% DCGL 13 Number of Measurements Above DCGL 0 Mean 0.485 Median 0.503 Standard Deviation 0.154 Maximum 0.838 Minimum 0240 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED RP Engineer I Date Z- -D r
- 4J7z,J// ~-
ACTIVITY WORKSHEET CO 8-3
- t-l
- :
Ql E ~ ~ gcpm ncpm Co-60 activity (total dpm) III ra Ql
- li 1
24 24 61,538 2 28 28 71,795 3 17 17 43,590 4 30 30 76,923 5 16 16 41,026 6 22 22 56,410 7 26 26 66,667 8 18 18 46,154 9 18 18 46,154 10 20 20 51,282 11 10 10 25,641 12 12 12 30,769 13 21 21 53,846 14 21 21 53,846 15 26 26 66,667 16 35 35 89,744 17 11 11 28,205 18 17 17 43,590 19 24 24 61,538 20 21 21 53,846 21 21 21 53,846 22 16 16 41,026 23 28 28 71,795 24 12 12 30,769 25 12 12 30,769 Co-50 activity (dpmJ100cm2) Unity EMC Unity EMT Unity 6,325 0.575 7,379 0671 4,480 0,407 7,906 0.719 4,216 0383 5,798 0527 6,852 0.623 4,743 0,431 4,743 0,431 5,271 0,479 2,635 0240 3,162 0287 5,534 0.503 5,534 0.503 6,852 0623 9,223 0.838 2,899 0264 4,480 0,407 6,325 0575 5,534 0.503 5,534 0.503 4,216 0383 7,379 0671 3,162 0.287 3,162 0.287 MEAN 0,485 MEDIAN 0.503 STD DEV 0.154 MAX 0838 MIN 0240
Ik1JctIt BSI EP/BP SURVEY REPORT Pipe ID PPH 109 Survey Location PPH RM 8, FD 8-1 See Survey Sheets Survey Date 2350-1 # 203438 Survey Time See Survey Sheets Detector-Sled # LVS1-101 4" Pipe Size Detector Efficiency 0.00039 Pipe Area Incorporated by Detector Efficiency (in cm2) 1.10E+04 DCGL (dpm/l00cm2) 973 Pipe Area Incorporated by 0.6 Field BKG (cpm) See Survey Sheets Survev Data Im'l Routine Survey X Field MDCR (cpm) See Survey Sheets QA Survey Nominal MDC Idpm/l00cm2) 2,366 Survey Measurement Results Total Number of Survey lVIeasurements 6 Number of Measurements >MDC 6 Number of Measurements Above 50% DCGL 3 Number of Measurements Above DCGL 0 Mean 0.479 Median 0.455 Standard Deviation 0.160 Maximum 0.719 Minimum 0.287 PHELPS Survey Technician(s) Survey Unit Classification 1 TBD 06-004 Piping Group 1 SR-13 Radionuclide Distribution Sample EP 3-7 Measured Nuclide Co-60 Area Factor/EMC Used No Pass/Fail FSS Pass MREMIYR Contribution <25 COMMENTS: ACTIVITY VALUES NOT BACKGROUND CORRECTED. RP Engineer I Date 4A/J/~-2 -V <f
ACTIVITY WORKSHEET FD 8-1
- f:l:-
c: QI E QI ~
- l f/l lU QI 1
gcpm 21 ncpm 21 Co-GO activity (total dpm) 53,846 2 15 15 38,462 3 17 17 43,590 4 5 6 12 30 25 12 30 25 30,769 76,923 64,103 Co-GO activity (dpm/100cm2) Unity EMC Unity EMT Unity 5,534 0_503 3,953 0_359 4,480 OA07 3,162 0_287 7,906 0.719 6,588 0.599 MEAN OA79 MEDIAN OA55 STD DEV 0.160 MAX 0.719 MIN 0.287
SECTION? ATTACHMENT 2 30 PAGES
BSIILVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form Date: 3-()' O~ Time: 1310 )( (~ Pipe ID#: PPH Co-of Pipe Diameter: Access Point Area: pro/2fY1 ( Building: pPR Elevation: D System:
'f-lQ...L-Type of Survey Investigation Characterization__ Final Survey 2<l Other v Gross Co60
~ Cs __ Detector ID# / Sled ID# 1-lJ 5~{ / __~!~O~/ Detector Cal Date: /..JS* 08'. Detector Cal Due Date: (. J. S". oq Instrument: ~~",-,----"s"-->o5oL-O",--------,----1 Instrument ID #: d 03 f-j37' Instrument Cal Date: / 0 ~ Ito 0 7 Instrument Cal Due Date: . 10 ell' o? From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value 3 cpm MDCRstatic q cpm Efficiency Factor for Pipe Diameter ----""-~-=-=-=-!....-_ (from detector efficiency determination) MDCstatic "2. 3 '" It' em2 (if no, adjust sample count time and recalculate tvIDCR.tatic) Technician Signature Pipe Interior Radiological Survey Position Feet into Pipe Count Time Gross Net I 2 Gross Counts dpm/lOOcm from Opening (min) cpm cpm 1 I Oroo I ~3
- 2.3
/ 2 Id-,OrM I dO J...() / 3 /3[)(o/D ( IX l~ / 4 /~f f IbOlo) \\ 1S t "1 / 5 I \\ 30
- So AI VA 6
d.. H()le ,v A' ./ 7* 7 3 ) 18' }K / 8 \\ J-I / ':50 ~rJ 7 9 \\5 ( ~5 ~'l / 10 b I I~ I~ 17 Package Page 1 of :) REFERENCE COpy, Page 1 ___. --------:T
BSVLVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form (Continuation Form) Date: '-~' 13' () g-Pipe ID#: PH C () - 0 r PipeDiameter: __Jf----'--(_(-----,--__ Access Point Area: r:!..;.-H-x-!....>;..t1']--'-----J'---- Building:..L-L-E-'-I--f____ Elevation: (5 System: _:J---'F'----=--->..U...L-- ! Position I Feet into Pipe Count Time Gross* Counts Gross Net dpm/1OOcm2 from Opening (min) cpm cpm !( 7 I 17 17 / ,) o* ( 1~ Id- / (~ '1. I L 3 13 / fY 10 \\ 10 10 / () f f ~% d-g' / rG I), ') ~3 .J-3 / Il /3 ) dd.. J--~ / I~ ltf / I S'- Ij / Irt) I~ [
- J-S
~S / t:?o 16 I 3L{ I "<:li / ~l 17 / C;/? c;g / / I / / / / V I / / / / / / / / / / / I V / / I I / / / Y Package Page~ of 3, REFERENCE COpy, Page 2 .<3ERVIC=-S !!'fe::.
.....I~ f cd~ (1(. f f 0, I,A{,,1 rd~ :n.Il,"<.' I ..,*0 *... ~ '0 ~4*\\-lDRI"'e.",- 'N SC(f)-r"'\\L N INv,cl.:-l-a ~¢HO'prPl!"':: .. -":~sa~.,,,r:.!:. ~~u'<. -'-Ill puMP !<:OOM N~3 PLOO/f!. '" L, 0 CO" III 'I In t? "S 8 1"0.:,, .,F,D, PUMP ~OOM N2j. ,"LOOi'? f-L o'q" ~d'" '/..." ",' '" + -4' <f ~1:::,'c.I* To ' ". u t;,"/IfjO*/r.:.ct..CCR '~I. / \\..' i 'I I " ",, ' ~ ,I,' \\; ,/'ll'~* 'II"" ""'1~;)''''-"' 1:EL,-SC,,-,.j: !t >" r, ,'H,,,-U WA-L ','\\', ", "",, '. I ~ I . ':\\' , I " ' I 8""8'Xq,"Te:E-~ ,.~ [.1/>'=1'1-2,. "'.~;; ~
- ,.'\\.~<.;.,~/ ",
.' '" 4: ,VR1..::- I* '~'1-!..;" < T', T .~*I ' ;Lf- -' -' "r f t J s"<} Ii'll", EiL. - 3~.3" i I -~--;,cr ~/NV.~L, -.:3"9 'I 1 ., '(j)~:12~-'--~-' _~.: HGAT tXCHANG~R R90~ld24
- )... FLOOR E
- L. -o,~6' lL_'
P'N'~P(':"K~~<!C', ~ p"r" se~,.or-aI:), -I-~--" J II) -/. ~, drain* flot under thICk wens
- i r---~--'11t),',
~ aiD l'rEMSln
- ,1 aLU IE - drains*
under thick cantrelle walls ,-:-\\ 't, - -,-, ,'1-""16.£
- t..Iiv',~.3~/'IMf. '
- 'G", - --:to
~0t!:.~ cp0l=~~~~~""O~'1-~-""" 5
- 0 m
m ,;0 m Z (') m (') o "'U leG ()L'~ I (.,5~ ,:," ~ ~' ,,-/"'FU;inri! ..;./ ~ l J >0
- a.
0 (,) W (,) Z ~.~ w a:: w IL. w a:: -I '--~ i I I i ~ I 'J ,'I' ~ : i ( ") r -:? ,~, < ("\\ ) -) ,r ,~~~
BSI/LVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form Date: 3, 13, ot Time: I 0 c? 0 Pipe ID#: PPH co - ;J.. Pipe Diameter: H--L-(_' Access Point Area: Pft! grn ~ Building: peft Elevation: Q System: _l-f...clJ"'-- Type of Survey Investigation Characterization__ Final S1J!l1ey~L Other tL Gross Co60 L Cs~ Detector ID# / Sled ID# __---=1..-'------'V'---"5=----""'_I_ / __-----'-1_0-----1-(__------= Detector Cal Date: {"~ 5 '0 r Detector Cal Due Date: {..J.-. S" 0 7' Instrument: d j So - ( Instnunent ID #: ~ 03 /f3 f5 Instrument Cal Date: / (). (G* () 7 Instrument Cal Due Date: I O* lb' OJ> From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value r6 cpm
- MDCRstatic q
cpm Efficiency Factor for Pipe Diameter 0.00031 (from detector efficiency determination) 2 MDCstatic Z.'3 /p 1.0 dpm/ l 'DC!) cm Is the MDCstatic acceptable? @ No (if no, adjust sample count time and recalculate MDCRtaric) C0mIEffnts: Pipe cui-o~t I F+ frOM f(low ti60Ct t t rt J-cJrlj Gee II Technician Signature ~l e~ Pipe Interior Radiological Survey Position Feet into Pipe Count Time Gross Counts Gross Net dpm/100cm2 from Opening (min) cpm cpm 1 I Orc)(J I 11-{' /£1 / 2 j' [)rotJ \\ I~ I.~ / 3
- 5' Orrjt)
\\ /t) /) / 4 t( flbo 4J \\ J£1 1'1 / 5 I ' ( (), lO VA 6 J' (H) 10;k" (' vI (')e-. AJ .4 / 7
- 3.
I /1) !S / 8 vI I ( R I~ / 9 5' / ~I ~f / 10 b I h b 1/ Package Page 1 of~ REFERENCE COpy, Page 1
BSVLVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form (Continuation Form) Date: 3 -(~- 0 g Pipe ID#: ~: If CO~.':2. Pipe Diameter: J-{_ If Access Point Area: Building:pf1 Elevation: 0 System: Position Feet into Pipe Count Time Gross Counts Gross Net dptnll OOcm2 from Opening (min) cpm cpm Irr 7' I 1~ I~ / I) ~' \\ P{ )J-/ / IS q' IJ J~ / H f(/ ~~
- l(
/ () If' / l J i / f6 IJ' 4' t / /7 13 ' J)' ~cl / ['if I if ' )d.. IJ / (4 )5' I I It 17 / I~- )b' / J.h db / o-l. 17 ' I dS I {AS 1/ _')1. {~' J .~ cf 34 / .1.~.
- 1 '
hn 60/ / / / / / .. I'j/ it / / / / / / / I / / / V / / / / / I V Package Page ~ of -5 REFERENCE COpy, Page 2
--5 I I .....t:.:. ;;. _~ ~;fe \\.t1 (\\+ '~. I \\. A. o o w (;j o z W IX W LL. W IX -8 '0 .............4"1-10 R'$E.~ N SEI': oe,:TA.IL N 0)@) INvE:lo;-l'..e. + IH~-A 1Nr',I'-';" Q ~
- l\\.1 D'P\\Pl!~
.._~~9a~Hci!. '$i ~w.... .'-9 -'-. 't ~.C"vR." '9 EUMP ROOM N~3 pI-DaR. :1., O~O." <n-, Is) . f .O"j}__"_-7..'_4-~ r-P.D. -fI'-- ----.- '\\II~~-I-". i " '~ ~ <:'q. f INV. E.L."S~O h....-.ACCtllJ".f o~""~*< 1 A~VIv4P"ft'Ok.4!~"')II'.,:.:.....t
- ~1-'.
- svMP. Olf'ArN -:-
-6"oj> s La 8 8"9 Ii'll!, EiL. -.3":f' ~ ~ I II
- --<C/;>_
~-=.... __ ic:.o.r-'--==: tNV. ~L, -3 ~'. ' '-J~ IV~1 ~-\\ , 7(J;~i'0". _L_.. __-3~..
- u '/ r::
r;," .~ HeAr EXCHANG£R Rgo~ld2+ ~-J.. p:LOOR EL, -o.!. I II) \\l.
- 1.
J + PUMP ~O~ 'i.e I I FLOOr<. 1;'70=0 ' S ~~i
- . 7~o*.____
0-28 ........ \\il, I I,{. \\ ~~I"LOO" DRAIN (r:. . ~.r \\ "--~_...I*""'-It-r-jA:Iltt.lv* .5li:/r :bETAlL. f-::N-J.¥.
- i
~--~--'----,,"l 'I, t:' drain* :not underlhltk Iwatls
- jalD l'rEMS In
, BLUE - drains " undetthick concrete walls ,":'t -ritE' !'I..t<v, ~3"' 'iNIi*. , k' ~-+.,r. "-t YEN' F<ISE~ (v~ .SEE!.z;J..All.. /6'_ ---1:.' ~. . ~-Fi:O~ .-/ ~ '. l e ~ r..... S F, D. ... 0 I~.. --I ifJ i I I, '4,.."....... --. , iI '.J
- '1 ea
( CQ-~ r..... 't-~,
BSVLVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form I2f Date: .3. J),{' Of? Time: K C~Pf5 Pipe ID#: PPN r: 0- :s~ I Pipe Diameter: 1-/_lt_~_ Access Point Area: pp/fRfY\\ '3 Building: --'-p---'P---'H..:........____ Elevation: 0 System: ....JCL.....L:Q=--- Type of Survey Investigation Characterization __ Final Survey ~ Other ~ Gross Co60 / Cs Detector ID# / Sled ID# L V~.-1 / t.O I Detector Cal Date: (. J.S* (J t; Detector Cal Due Date: Instrument: ..J 3> SCi- / Instrument ID #: Instrument Cal Date: I 0. r, *kO? Instrument Cal Due Date: From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value 3 cpm MDCRstatic q cpm Efficiency Factor for Pipe Diameter () J!X5D3q (from detector efficiency determination) 2 MDCstatic 23ft; It* ~_f~ cm Is the MDCstatic acceptable? ~ No (if no, adjust sample count time and recalculate MDCRtatic) Comments: Slvt(,-1rd t:( -TOi 0() (() f s/ 5:r: sC{((/( / r Technician Signahrre ~j.M! Pipe Interior Radiological Survey Position Feet into Pipe from Opening Count Time (min) Gross Counts Gross cpm Net cpm dprn/lOOcm2 1 I I d-) ~3 / 2 J.. I d h cib / 3 ~ / / ~r I v( / 4 J1 I ~.l) d-S / 5 S f ,.l~ ~J.. /IIVA 6 6 noel' De / 7 7 \\ .1 f{ ':> () / 8 ~ \\ HJ.. J-, J- / 9 0 3b ~ 6 / 10 f0 I 35 ~ s / Package Page 1 of 3 REFERENCE COPY, Page 1
BSVLVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form (Continuation Form) Date: 3.. Iq-o r Pipe ID#: Nilco s-( Pipe Diameter: __).{_l( Access Point Area: -wPp'--,OHc-..IrR..p-.l-f1I1-"----3__ Building:.f.l-fL..-:H'"'--____ Elevation: D System: EO Position Feet into Pipe Count Time Gross Counts Gross Net dpm/lOOcm2 from Opening (min) cpm cpm f( II I ct5 d,j n,1J,./ / IJ. J} I 37 37 ... ~ / ~ / / / /v / / / / / / / / AI/A / / / / / / / / / / / / / I / / / / / / / Package Page ~ 0[3 REFERENCE copy, Page 2
.... 0:"'\\ -- D~ :) "rJ p(\\rt o-f p. r~ 50f')
- f.
Ov'~+O (0(12 bOfl~ PUMP 1<0£11 N.e I I PUMP 1<0011 1'/92
- 6," --1***,
/'"LOOR E
- 0 -0'
't): nCaR. pl.. 0 10" 'F()~ CO\\J'TI\\JU"\\OtJ,~~_~~ S"-e>. pl=-~a," I _. 7~o*...__ EO-28 :~: ~ 7~O,:. _I'"i..Oo/? DRAIN(;. ~ I~,*_P.D. I I '14 Jltl¥* SSE: :be."'All. '.f-,N-~ ,4-'~ TIiE.
- l.G-V'. ~3~,*iMV*.
S
- a m "
m
- a m
z .(') m (') 0 "tJ
- lalD ITEMS In
, aLUE drains* undet thick concrote walls Idrain -l'lot under /hICk ,wans
- i It)
I'~' HeAr E~CHANG~~ R~O~ld~4 fLOOR EL. -O~Q I e"c} (4'- -- -'--_.~ Is) -I. 1.9. 1 e '::+/-;T 3,,¢HO'Pf<>e":: ~'Fi:O~ . _~~S~c:f:. '3~')\\<'" [ .l. '0 -........"-....-4"\\-10 Rl-;'E.I>.. "C\\l 5E C,....IL C\\I e
- '\\<I'(."I-B
.o.,~__. _..-Z-:!I,._ ,..,:',D. (j-_.-----, ~ ~ 4-**.. 18t1*lE.L.-S!..O** I I~D-C I "'-AC-C~.J",[ "~"'IN<,, I A6()1<*d"....pp~,t~:C;1r4.:..4't CL o (,) W,. (,) q; Z Wa: W LL. Wa: ~!Y4.,~M'P..GW7,40{ -: '0 -'G"¢
- l
.....*01_.. --'f.' 1& j <E EL..-S~4-** 'i I THRlJ WAL.L I I ~ i '.. I'J .i j '01' 1 ii ( I <: c'{ I' ~b~
BSIILVSPipeCrawler-002 Revision 6 Pipe Interior Radiological Survey Form Date: '1 '. f(. ~Z' Time: () g 3. 6 Pipe ID#: ffl-l C() 5~~ Pipe Diameter: __I1_"""7'"f'l-I Access Point Area: jfHRM 5 Building:.......f...:....f_It.l...--____ 'Elevation: C) System: _PI----=D Type of Survey Investigation Characterization__ Final Survey bOther ~ Gross Co60 _~_ Cs Detector ID# / Sled ID# L_I/....::.>_-..Lf / --l.I--"o'--..JI Detector Cal Date: "I* J. 5 ' 0 g Detector Cal Due Date: Instnunent: ~ :5 5' () - ( Instrument ill #: Instrument Cal Date: 10' /6' 07 Instrument Cal Due Date: _---L.-=-----'-----------=- From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value ~' r cpm MDCRstatic CI cpm Efficiency Factor for Pipe Diameter D.voo3'1Io.,~, (from detector efficiency determination) I 2
- MDCstatic Ulo/,p */111 f.5 dprn/
100 /1 0 cm Is the MDCstatic acceptable? (Xi) No (if no, adjust sample count time and reci!!culi!te MUCRototic) Comments: I 3 I Cl {tf'pE'. ;:5 t! If i A-R. ('~ 5 ! r'"),(r Technician Signature Pipe Interior Radiological Survey Position 1 2 3 14 5 6 7 8 9 10 Feet into Pipe from Opening J 3 v( S £ 7 ~ 1 11 Count Time (min) I / I \\ \\ \\ 'V Gross Counts I;). ~C{ 6 ~6 j9 }b /3 Jf fJ.-i ~~ Gross cpm It /q b 16 3f ! b 13 /7 )1{ dJ / V Net cpm / / I dprn/lOOcm 2 I / / / / !If VJ1 / Package Page 1 of~ REFERENCE COpy " Page 1 t3e~fvrc=g Il'-'C.
BSVLVSPipeCrawler-002 Revision 6 Pipe Interior Radiological Survey Form (Continuation Form) Date: JJI'--l/l / Pipe ID#: PPH Co 5*1. Pipe Diameter: ~(7// 0 Access Point Area: PPN gwt 3 Building: PPH Elevation: 0 System: ED -I---!-----'-"---- , dpm/lOOcm2 Net cpm Gross cpm 3f /11 A ~l I ~ / 30 I I ~ / 30 / ~o I ~1 / 1--10 / 3..2. I I 1 0 1 ).l / 3b I Jr /
- )..5 J
3b / 37 I 35 I i dJ / I I 3q I I ~l 31 Gross Counts I
- 17
\\ I / ,I / \\ / \\ \\ I \\ I Count Time (min) Feet into Pipe from Opening )<7 II r~ r 7 I b 3{) 31 J'1 3S Position I( () (~ ~( 27 3 1 Ida I It) ~ I ...........v / ~ I ~ / ~ / I ~v / ~ I ~ 1/ Package Page ~ of ::s REFERENCE COpy, Page 2
I --- I I I\\)'J\\'" -=t- '.J ~" :~-~., ~/.i ~ "I (c ~'1-
- 6,'. --;/,:
l=QQ", CO\\')'TI\\JU,a.,"',ot0 s...~ PI"~Qe'1 ,'.-,~-~~I ~ lEV.; ," i _I,..,;3-/ INV.,. ~ 'laiD 1'r~MS In ( BLUe: - drains" under thick concrete Walls r-~~--"it; 'I. drain" nol ~ under thick 'walls ,-\\ 4 - 1J)., \\9. 1 PUMP RooM "'2 I PUMP ROOM N9Z ......EJd.MP RooM N'"-3 fLock !!t. 0'0 ' f'l,.OOR. El. 0'0" F"LOQR =c... oeo" ,_. 7~o*..__,...). III 1~o..:... ~. ~ _._..__ 7.~o". "'~O"I!. DI;:AI,'-/ Cr.J)~ ! "'"llrI \\ !'"/IT. SEe: be'Ale. ~--.= -:3~" o'p," .._:~9aRV\\c.l!. ~ '-4**fTelt:*, +/- -~~~ ~:i:+/-!' +/-~~ r 4 31 \\) "Ii ~ ~:l.t ""---4-"1-10 RI~e.P.. '0.'N .--~.......,"/': '--: IM*y. H, -~~!,.~.. : '.,;1",."'"0', ::...-J.._,.__.__.:l:!"""--_....~~. 5<=01>.,...,, 8 @ 1~V.a.;-,lt.B'" N I I UJtj_/~= c," --"~' I I, '<;j ,J,:.!W.l""c:;.*f iN v, e.L.-S~o'* i:1 ~AtCG'.tJ" oPr:"')~~~,., I A~S.,APPROI.tI_f$ ;K"f:';:' 1 ~ a"<} I Nil", EL, *3~3" ~ .L
- 3t,,"'"':-S,&,MP. OI1",~/N
.0::;' '¢ Q ~ ~~L'!~'" +~ ~ P,D, .,"0,.. -~ ~ ~ 'S u.: "</> B ._j L. -5'-2-".'/; "'-U~WA:L \\~ 1-i 8"AS"X 4c"TE.E.-" * -. I ".', I .~_ ~FLo"[ I -Of ", j I i I I I
- J I
- '1'
~ (
BSVLVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form Date: ~, tf,O~ Time: oQ3 :; U( lif(_6(f Pipe ID#: CO' 1~ Pipe Diameter: r/ Access Point Area: C(/1-1-/ Building: "pC?p"'ijc--;-'-----'------ Elevation:
5--"----
System: '!Pf:~:'-----'F'--='-Q--- Type of Survey Investigation Characterization Final Survey 'P Other ~ Gross Co60 / Cs Detector ID# / Sled ID# ___t~1/5=-~---,-(__ /
"--"'{Q'---'--{
Detector Cal Date: I'd.. 5"0 r Detector Cal Due Date: Instrument: d 35.....0 - f Instrument ID #: ---'='--=----=------'----- Instrument Cal Date: (. ~ 5" 0 r Instrument Cal Due Date: From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value .:2-6 cpm MDCRstatic ~,5 cpm I Efficiency Factor for Pipe Diameter f).~ /O.P1JP31 (from detector efficiency determination) / 2 MDCstatic z.3lol£I \\~ ~ dpm/ 100/, 0-0 cm Is the MDCs1alic acceptable? No (if no, adjust sample count time and recalculate MDCR'latic) Comments:
- c. :#.3 a
8 I Technician Signature /2wwJyf. f~ Pipe Interior Radiological Survey Gross Feet into Pipe Count Time Net Position Gross Counts dpm/lOOcm2 cpm (min) cpm from Opening I 1 11 I (~ l / .,l3 ~3 2 / / .2. ),1 3 ~l .3 I / y /5 ~ 4 15 / .l-q 21 5 /A S AI 2j
- 2-.:)
6 / b \\ 7 c:z\\ .2.-1 / 'I \\ \\
- 2.6 8
.2h / 8"
- ),7 Cj d.-l 9
/ / 10 10 ~~ ~2.. V REFERENCE copy Package Page 1 of 3 'fiJcock, Page 1
BSI/LVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form (Continuation Form) Date: d' ((*08' Pipe ID#: ---"(,-,,o,---J--L/~_(_- Pipe Diameter: __Lf_...----::~,..=.b_(_r __ Access Point Area: ---'-p----;:P:;-:'H=- Building: pp(-f Elevation:":J System: EO Position /( ,0 [] I'f () f~ r7 (<{ rq I Feet into Pipe from Opening I( (1, 13 1'1 f) (6 (7 c'( (4 Count Time (min) I j' / / \\ \\ \\ \\LJ / / / / / / V Gross Counts Gross cpm ~J1 ,;;(r( .;)..( ~I L ~ / \\I 11 1 ~ oZ(
- 2(
J.-*l
- )..7 3l 3J
- )S J-!J I I l
/ / / / /1/ /f} / / / / / / / / Net cpm / / / / dpm/lOOcm2 / / / / / / V / / / / REFERENCE copy / Package Page ~of 3, Page 2
. 1"
- 6..*.. _-1*
~~~ ..-/*~LO*tm:" ~ I s -8
- '--1 "
i I I 4 I WALL' t-.. - ~ - ~O-t>- I _S-,,4- ..__...J ~ ~ .M,* -r-:'0b( ~1.,-\\i9TP!5ih1!>l > I N. -~
- f>P;C$UJ PRN~'
1Nil, eiLI
- 3~d" r(IMV.,5:L'~'I I
- ---::;- C. ":'4'~Hbr'P~Ir->.-'
I 8"...a*... '/'**TIrE:.* i; ~"\\(~.....~.... ".': I,. (4""' , ~ ~I~~" T q / \\ I _-.1.. o* '111 /I 'J, Ay.jO'/:::' ~LCC~. OJ l
- I
~( i/~ I"~' 'J .<0 .. f!\\~...-::-'!-:-: '--';'7
- 1
'!;§.L., -s!..~.. j! [~.\\\\~~:~t.. I ~ -, H;..:.u WA~L . '..\\..;Ii-. '. I. / .\\ (\\ (I L (Gf\\ 1/ ~
- ~:<~,z,:-":";~';;
..// 8 ,I(; I i t-.~;** '........~ ~1......x-.. '? !VR.*~* i l:*'*. --- J.,;)SC I gl, C(l if 8""8*'~4."Te:E~ ~
- ~).
- l.f---f---*-~-*I(j 4'$
I I;'
- a.
o u ,'C' W U Z w a: w
- u.
w a: .. 0 J_ ih '0 .1 '""'-4"HO Rl~e.R. (IJ 5Ee,. 0\\;.".. N ~ @) INV.a..:--l'-e.'9 ~ ~ "L.""'C:' + H~..A -~ P,D, '0 ~ PUMP ROOM N!!.!3 F/..ooR. =L, o~O" l 111 "'III -,--I ~ I I r 4*"1> INV, EL,-5~O" ~ "'-.ACC('IJ'J" oPt1",,.,~ ~ I A8"lV'8'..APPA"OX4:~1c'.,~..t
- ,~4;-s.v"""p,*DJl'ArN.~
s 7~o..:,... ~. PUMP ROOM,,~Z A PrOOI{ aL. 0 -:>.1 _s.:5':']' -6"0 F.r;, FLOOR. EL. 0'0" + DE:ror-JIZER. ROJ,M N!!.~ ~ "!-"? 5UMP PI, Y..NT 1,,-: E:L *""O**'.4,"?lI WAf'LL '" ~ .. 5 ~ i.., ~'" ._.~ 't: ~L, '--__~-'. THR.<J ~ ~: ~ I II
- .J:...P._
~ 'i'q ~'f 'f'lx'. EL, '3t;~--~L,v..,~",' !NY,'~ "vt?" HE::Ai E><'cHANcSE:r~ I$c>or-l d 2 4 FLooR EL. ~o.. o' +---~---'.' "!iNr RISEldvl<;f .SEE Ve:TAIL. PUMP RooM N~ I f9LOOR. Et. 0 -0 ' .~o* ~ I ..-- SD2 ~I I III ~~.. no,,/? DRAIN (~ .. 8 '- GE:.oe:-rAJ L. . ~. drain.. :not under fhick wails ': i ~...........~-...,,\\tj .\\' ~ 'I~ID ITEMS In
- BLUE... drains under tliick concrete walls
,"':'1>T1E.E
- '!..~V, ~.3~I'lNv *.
II) - L. L1S-I ~, 1 ~o~~;6~~~~'ow*r' Sltd I V I WEe ~ II' C ~ J 01 '.,) /~ I.,.... 'i' ~
- 1
.i' ~~~.~: ...J".." '" ~ ~
BSIILVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form Date: d'8'OS Time: rYi3Q Pipe ID#: C () ){. c6. Pipe Diameter: Jf " Access Point Area: (O t-{. ) Building: PI'; rYIl\\f Y Pv.~ ~ 1 Elevation: (2, System: Pr;vMrt P""tf'1t) Type of Survey Investigation Characterization Final Survey Other 'f... I Gross Co60 V' Cs Detector ID#/ Sled ID# 1m 6/ Ii- (K-, / 5/('J I() I _-=--'--'-"----'--------'--:::.....-.L Detector Cal Date: --1-1-,'d..::.,:)",------,'O::.--.:..<f Detector Cal Due Date: /-.:;.5'01' Instrument: ---""d-,-,-=3=5~Q,--_I Instnunent ill #: Instrument Cal Date: /. J. 5 '0 s> Instrument Cal Due Date: ~--=--='------"-~----- From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value IC* t cpm i\\,fT\\r'D tf "pm l.Y.t.-l.../"-".l.'-SLatiC \\ v .1.1 Efficiency Factor for Pipe Diameter 0 1'0 003 t) (from detector efficiency determination) 2 MDCstatic Z 3 LP LP dpm/ l V V cm Is the MDCstatic acceptable? ~ No (ifno, adjust sample count time and recalculate MDCRstaric) Comments: R-ta.J:/1 1,'(\\ 1 h~re. b0 ..Cs/J?* Technician Signature Pipe Interior Radiological Survey Position Feet into Pipe from Opening Count Time (min) Gross Counts Gross 1 cpm Net cpm dprn/l00cm2 1 Orol) ) F~ I I 7 } I / / 2 Dro/J J.. F l-I J.5~ [~ 3 ()rn,fJ ~ Ft i J..J-. ..1.1 / 4 PJ to fJ L-/ Ft j 14 J'1 / 5 Elbow SFf 1 IJ (3 j) VA 6 6 Fi 1 til iii / 7 7F+ I / 8 R'F1 I 30 so / 9 c[Ft I db d b / 10 loF+ I d..-O ~O V r Package Page 1 o~3, Page 1 1JtJJcock REFERENCE COpy
BSIJLVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form (Continuation Form) Date: d' g, 0 g-Pipe ID#: Building: C. () tj':h p""rnp I?vn J1 Pipe Diameter: Elevation: rf rr () ; Access Point Area: System: C() '-I ~ ~ ---:---::---------~- Pt,'ff/Ci!f'r fhtnfJ Count Time Feet into Pipe Gross Position Net* Gross Counts dpmllOOcm2 (min) cpm from Opening cpm / 30 {I t II FI 30 I ,;(3 (J I 11ft d3 I I ,)..1 /jr+ 13 ~..l I I 1L.( F+
- )..t1 d-.Lf I
111 I )0\\ 15Ft d..~ I 'S
36. I I ~ b I bFt /6 ~O I )7 dO I 11ft I /) I 1~ F+ IS If jq
- 1, IVI F+
I /1 I / I / I / I / I 1/ I k / 1/ I / I / / / I / / / / / /A / / / / / I / / / / / / / / / / / / / / / / / / / / / / V r Package Page 0- o~, Page 2 d\\.-- 71tiJcock REFERENCE COpy
r~ C'-f"' '---I"' '0 PUMP R.OOM N~ I PUMP ROOM flgz PUMP ROOM fl~.3
- 6*...- ---1*
novara ~L. 0'0" Pl-ooR..=L, oeQ" (' F'LOOR. et. 0 ~o
- EJ' ~~:
~~~ ~ ~ o .,:~ (,,) at W (,,) Z W ~ III
- u.
III ~ HO-B .. _.. (ll~.. -~ '0 ~4....... 0 RI$E.R. Io~ 5H,Oe","'-IL N (£) 'NY. l'\\..c\\-l!o ~ 'EL:\\"IO' + HD-A -~ F,D. 'a
- j.
':3"¢,, C*P(e>e. _._:.9'i!.~\\ce:.~i~K.... III 'J Is) .0"0--..,.7..-:4-._ I /;:'.v. f;/_...-----.- ,.rr. ~ 'c-:." 1 4-+II'I'I,IEL,-5-0 -, ~AC'ce~J" Q~"'J#~ I AcJoIl6.",4PPRQJf.q.:~""}t",~'t ,:.9-/,...""'t-SV.r4P:O.l/'AIN 7 <;"0 7~.o.::_. ":+/-i -~. /'":-~ "...~, ( - 4*,,';: ;<'1 ::'101: TO" ~, / ~ Af:)OV:::".CL..ccR. ~ I . ~ 4> . I I' ~. -.... j l\\~'-~'I'-')'''-'r- Ii'*, <t EL.. -5'-3-"-1; \\'.\\ Ii' 'I' l j'/-,.:",:,u WA~L I ~ ~ J -9 ~'..."-....... ~/ 8 \\.. ~I<£.<l""""'.,.. -.ti I j: -,~-;- . VI? ~ 8"c} INv', EL. -3~.3" ~/1'IV. E/-, -3!..$*' aJti:12:L----~~,:4~~ I H§AT E><'C/iANcSlEFt. Rom-! rig 4 FLOOR EL. '6' + Ve:rlT RISER '(1/1<)" .5Elt J)E.rAIL. -I~~---- Is)-, ~. 1 -. 7~o*.__ ~ HD-2B \\I), I ! 'ii Jlio:) tJ!:~noo" DRAIN 0=, ~I .sE:E: De.rAJ L
- drain -'t1ot under/hick walls
- I
,..,~~----" It) ~ 'BID l'rgMS In
- IBLUE
- drains..
under thick CQnctete walls ClG.AI/.OV; (c,o) ~.~
- -- ~L&~ -3~'iNV. ____
_'iCl'!....-VR: i ,-t-'tr!iE "'.. IE., ~3~I'iNiI. 1,°F~~"i~~-fIO~' -~-....., 'I ..--/-Fu:,-O~ ..;/ '[ ~'" ~ 5 "--1, i I j I i (4'_ -- I I 'J
- ,1
~ I J ' 8"1<.8'x4"rE:E 1- -- r~.. *fl-r-' ( }'",.; {qk'(- ff CLl ~ f\\ -I t ;I,C, (('I.. ...) [ (jlC:, --k ~. 1 t'" C(\\. ( IJe I'.. I 11 (I
- 't.'
'hi""-\\. rtV l"A ( I h.C,
BSI/LVSPipeCrawler-002 Revision 6 Pipe Interior Radiological Survey Form Date: 3* sf- ()g' Time: rJ900 .DpH ~( I' I' Pipe ID#:, CO Jj~ :) Pipe Diameter: _H./....-...C-fo'------G-'---t-"--O----'['---__ Access Point Area: fey trn J( Building: ~f..J...f~H~____ Elevation: 0 System: ....lf~!J=--- Type of Survey Investigation__ Characterization__ Final Survey 'f... Other y Gross C060./ Cs Detector ID# / Sled ID# __.::::..c..L_V_5_*_ / _ _------"-,.>C-O->-{ ......:.-1__ Detector Cal Date: /' J., 5-' 0 r Detector Cal Due Date: I ' J.- )'.() q Instrument: ~ 3 S-cJ - f Instrument ID #: ~ 0 ~.J-/3 l( /() *16*~n<17 Instrument Cal Date: -t7 '(, v Instrument Cal Due Date: I (). 11'0 P' ~~~---=---------- From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value .3,~ cpm MDCR,.uo q cpm /Z.; Efficiency Factor for Pipe Diameter J.q£-4~.J{IlJ'i£- (from detector efficiency determination) I / r 7 MDCslatic ZJlJlIJ tjB'6 &iql dprnl'fo/lflO II 00 cm2 Is the MDCs1atic a~ceptaJte? cx;:J No i (if no, adjust sample count time and recalculate MDCRstatic) Phi r II I r r( vi / (' II, Comments:r'lJe Ct5 8 Cl1' J-f 11-/ rJ 6 Vi Yl dO O"t rY I'le' Technician Signature ~!l!.!~~)~:A.:..:...,--I-f...L14r.=----¥-4~sL-------- Pipe Interior Radiological Survey Position Feet into Pipe from Opening Count Time (min) Gross Counts Gross cpm Net cpm dprnJI00cm 2 1 I I ~O ~() / 2
- L
/ )0 )4 / 3 3 I
- 11.
/1 7 7
- 1.,.
t{ ~H J..J.-[ 5 / & I b N A 6 h a~ c22{ / 7 '1 \\ I q I q / 8 ~ \\ d..~ ~5 / 9 q \\ I q I '1 / 10 10 W' ~3
- ..-s
/ 'Bdicodr REFERENCE COpy Package Page 1 ofl " Page 1
BSIILVSPipeCrawler-002 Revision 6 Pipe Interior Radiological Survey Form (Continuation Form) Date: Pipe ID#: Building: 3'.3/' at (( r tr t Pi! C() t{ A 3 Pipe Diameter: _4,---,f_o_b--="_0--,-r__ +f..L-e~H____ Elevation: 0 Access Point Area: System: fffi tM.J-I -I-F~()..!..-.-- Position Feet into Pipe Count Time Gross Counts Gross Net .' dpm/l00cm2 from Opening (min) cpm cpm I( If I~ 75 I /1 J) I GJ q I 13 L~ I j I,) 1£1 I vI / Jt1 J t I I~ (~) I I.~ /3 I It It J..).. .}r{ I J7 17 )/.. I 1~ I If l-P I ~ I.~ I 1'1 /1 JS IS' I I;) r')
- ).0
)1 /q I ~r d( 30 30 I J.l .J.l.. J 3 I 5 / 1;)3
- )3
- lL
~J1 I ,:{'1 d-- r( d..~ .:2-). 7 1,) dS \\ .1l ~l I I;:J 6
- ).7,
\\ Sb ,Y6 }I/ !r ~7 r:J 7 \\ t/ J1 ').[l{ II
- J
~f d-.f d--7 .:2.1
- iq
~7 ~7 I 30 ',50 f; j 5 Jr I .'5 ( 3r .':5 S ~b I I~ ) 'Sol \\ ~5 3,) I ~.3
- s'3
~l .).1 I 1< L{ sJ-f ell-{ c2J-f I 35' 1,5 I'i" If I 36 ~b J b I b I ~7 ~7 c1.o J-O I I ~ 8' <.X-r ~'3 ~3 I l-:s C; 7,1 .;LO .:LO / >-LV tfrJ I l).. /). I L-lf ljl t /7 \\ '/ I 42 CfJ.. \\J/ /1 1 I I I / / Package Page~ of3. REFERENCE COpy, Page 2 _E.~'./-::;~*- 1iG.
"~"'" r
- J-_'-.*.
I C'f', I ~ I '0 ~ 4';~D Rl"='8.Q.. ';'N SEI; OcL N o,,@ '>-1-":1'1."1-5 a ' EL;'~"" -I- .4 .'.. q "0 ~ -L-PW1P ROO~1 N~3 Pl.oOIC "L. OeD" IT> -I In --*.~ -I I ~ I. q.". i,-.;I/. ",".-5'0" :9 ~.A('C(lJ'J' ~1¥"'Jnc ~ .. -i;. Al8CIl,f'.A"'Qk..~..s~..,;';lt
- .3/4 -sY//'Vt,P "D17A I'N
.-.","4> ":::b n 8 ~~ ~,\\li<:"l~ -'- t1il' ('.;
- >~=:JA:
~ i " [' "<I- ..7:.0:~.,.. _ .. ~.D, PUMP ROOM Ngz f:I,.OOR. 1£.[' 0 '0" -<i"<C.SII.l........' 4! _~ '1 8"~8"x'/;.'iEE..
- VR~I i3 "<} I N v, fit.. - -3'.3" -"\\----0 i
I ~~----,;.,c.()Jf "i IN'y, E£.. -3'-$
- I
,/ ~.,._ ClJ4:i~--;--'-'--- -10" "-[00"'- Oft. ""0 ' -,..---"n.ooF!. DI<AIN c~.b) I sE:E.ve:rAIL I HEAT EXCHANGl£r<. R90r-11'1'21 F"lOO~ EL. -0.'.6 i PUMP ~OOM r-Je I ,_.7~0*...__ I. '-I--'._--' It) '1. \\.!l. VENr RI5.ldll~* .5E'.E':.oS-rAIL. ,....-~~--"l Idrain
- mt I'~
under /hIck walls '1£lID l'rE:MS In i £lLUa. drelns
- under thick concrete wells
,-it11ic. "l.iE.... ~3"t'iNV*. COUihJU......... IO!V.r-~ __.., Pl=-~oo,"'!' .. _*1*
- 6'
'Fa=.. S"- \\'!' . ~-Fi:O'lJ'l<< ~ 1: I 0 ~ 0 W o ~.~ z w S a: w LL. W I a: -I -~ F.V, _. Ol~. --1., -J... N j i I <to EL.-5~4" I-T~R':.. ~A_L.~ I '04'~ ITT O~i;'N-' I ! ,.",/-:-1 :;"", /4'.. --. . 'ri / ~ \\ ". ~"-'<:'i: 'r0";3, \\ \\ i ~'. ~ c~,.., I I, ~*,Jo"m. -, ,1.__.._....... 'J -I
- '1'
~\\--~~r)/ .\\ I 1-. -5:'~".-" : 1 \\ ,.'., i './...
- '
- ~W';~L i \\.~.,.,.-,.:// "f'.',:
- ";:"~-):.;... ';..:,: *r~
~ ( "4> 0 I I l~ " ~ l'" ~ --I JI:Li b--[) ~, . ( ~ ,'/ ~~.~.~
BSIILVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form Date: 3.d-.7* O? Time: I 0 J-{ 6 I/Co~?:1f I '/ Pipe ID#: fi 0 - 0 Pipe Diameter: J-I Access Point Area: -'--=-'-c-T-+-------=---- Buildin : levation' Type of Survey Investigation Characterization Final Survey ~ Other ~ Gross Co60 / Cs Detector ID# I Sled ID# L----'(j----'S=---~---"--! I ---'-(_O___'_( Detector Cal Date: ( '.l..)' () 7 Detector Cal Due Date: I ' J...:> 'd ? Instrument:
- Z.$ ~o.- (
Instrument ID #:
- ( 03 L-/ ~ r
--=-=-----==---------=-----"------ Instrument Cal Date: 10- I 6' () ( Instrument Cal Due Date: I 0 ' lb' 0 f-From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value
- 3. 7 cpm MDCRstatic l 0 cpm Efficiency Factor for Pipe Diameter 0.1)003 q (from detector efficiency determination) 2 MDCstatic "2 3 lo to dpml I C/O cm Is the MDCstatic acceptable? ~ No (if no, adjust sample count time and recalculate l\\JIDCR,tatic)
~ Comments: FO ~- '3 (s cOV"\\1' !~f~Jf jone-, R,'se!<. For?. (Q8-}>'1 /5 COrJjJlef/r Technician Signature ~_.'----1-~---=----flVA...."""""'-------- Pipe Interior Radiological Survey Position Feet into Pipe Count Time Gross Counts ' Gross Net dpm/100cm2 from Opening (min) cpm cpm 1 I ~~ ~~ / 2
- J.,
( ~ 3 J,3 / 3
- )
( d 1 ?A7 / 4 0
- )()
- J()
/ 5 ~ I ( I I ( 11/V4 6 h I I L) J c:; >/ ( 7 ~ / 8 AI ~ / 9 ~ V1 / 10 --- 1/ Package Page 1 of ~ REFERENCE copy ticock ERvrc,."r:l.S' it-Ie,, Page 1
( .~' ~ ~ ~~ p G O (.) w u zw ( a: w II. W cr --r i I I I i j I 'J"I ~ . /"Fi:O'i:>~ ~.L l.ld* 0<-(' ...° 0._. -J,
- 1,
'0 .1 4"'lO RI$"' ~ ............ SCCf>:'-tl.. IN~i:.L.~l'-B" + O'~L:."'G,. " -'"'" F,V. '0
- j
-'"---______ I "3lH D'P," __-.~se-'~lIc;" 41<.. + .4. ~~ -Ii ...:... '" <I) __.....J:.~~ PUMP Root1 tie", PLOOf'<. Sl. O~O" III I ~ r i t I"
- r{> /,,,'0{. 6L.-S-0 ~
"'-ACCCSS ofl'ft,.lIHl; ti .. ~.. "'6<>YIV'fpr,,¢x.".;.~"~"'~"'f ':'!/~' -SV.hfp,.o,lf"AIN -'6",? ffi 8 ..7~a:: PUMP ROOM ~9Z ncOR. E.L. 0' n' e"q INv'. elL. ".9:.;".-... I* I icr ~ ~I~~""'I ~ll'IY.IE.L,'3-9
- I 5"
CD'4:i~~~--- _._-~y~,~,~~ ......!:!.5.AT l::X.cHANc&~r<!. ~O!("'l ciS! 4 1 f'"LOOI'! EL., 0 ~-~ Pll~".P t~AKAr;t! r"l'r ol ' S~~ Pr~O¢< P!JMP RoOM NZ f ,..[OOR. eL. 0:'0 ' I ,\\ D£/oNIZE:R R9~M N~t;, Fi,oo.~ aL. O*::J,i ~"i':3'::'J ~ +'¢ UMP (OJ";' VE.NT 'j '!:EL"4-'D.T~"~WALf '/:1::(...-5:4-" ~ THRU WAL.L r .a;" " ~ - ",L.-:~'~" '/,,;(:- L.-i}'I" I I :.:"'--.-.*:;4,.~Hoi 0,,0;1"';'; .*,.S*;"" I' d' or I R.t-=,*e/~ To'l~~1 / \\.\\ '-1--~-~-' 0';';' t=u:.cR,. "l f . ~ ,ll I_ .,\\ . 1*\\~*.~-;i~,_cT iI\\.', ";1,' /r' 't' 1\\., *...'..,./ 'l I . ~ " /. 8",~
- ' ; '~.f'...;~';* f
- ' ~I.:
8"*8"~4:**Te.E"*-_- .: '1- -'- f" -_. -'f.l ill 'I. \\l. +.t VEiN, R(5e.1t*(II~'* .SEIl DE-TAIL _..,*.. 7~o'. I I II( _~~naol,i1. DRAIN o-.JJ:J' ~-1r" 5';'/5. De.TAIL. r.~.~-"l f/rain * :nol I'~ under fhick walls '11310 l'rEMS In I BLU ~
- drains" under thick concrete wails
~Oa~ b~~~~~1"'O~"" -~--, C' 4 -...'" 'S
- tb '.. ---1'.
~.,
- LO{ )
~~...
BSI/LVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form Date: 3 - ~ b* C '?' Time: 1'1 SO t.1 of Pipe ID#: PfIlCOg-b, Pipe Diameter: Access Point Area: PPHI( VVl F Building: f~ I-l Elevation: 0 System: ED { 0 I Detector Cal Date: {.~ 5' 08' Detector Cal Due Date: ---=-------=------ Instrument: ~ S 50' ( Instrument ill #:
=-...::.-=-->:"'------=-----'------
Instrument Cal Date: /(). / h* 07 Instrument Cal Due Date: ..:..=..~-'------=---...:_---- From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value "3 cpm MDCRstatic l' cpm Efficiency Factor for Pipe Diameter ~ *'{)v 0:3q (from detector efficiency determination) 2 MDCstatic 7 3lo {P dpm/ (0--0 cm Is the MDCstatic acceptable? ~ No (if no, adjust sample count time and recalculate MDCR,latic) Comments: (0 '?- d- /5 (0 ltl1 Pf~ 11'( /So (( d. Ou t a I;t) Co f'..L 0 rup i 5, Co /<.1& (~+ /1 hoted Ov-f Technician Signature R~A* fJ~ Pipe Interior Radiological Survey Position Feet into Pipe Count Time Gross Counts Gross Net dpm/100cm2 from Opening (min) cpm cpm 1 { f (~ t b / 2 J. I,) I 3 / 3 j I ~ I, / 4 )..1 \\ 11, I~ / 5 ..;.) I 1 8 I~
- VVA 6
/ 7 / / 8 ~;{ / 9 -~ / 10 / Package Page 1 ofL RE Fl NeE COpy, Page 1
- A/
-~.....--..--_._..-------
- ' 6'.* ---.l
'FoQ.. '0 ,1 C\\l N 4"1-' D Rl",aR. "- 5'E1" D"'--\\L 0@ 1"NV.~1...:-1'-B'" d H'\\"~' ~, -~ P.D, r- ,A a
- J:
- ~I-1D'Pi'
.._::SE,R-{v::. e. +- PUMP RooM W3 P!.OOR. ;oL, 0'0" <n ~ ,,_.7:o'~, ,P&;
- 3/-t""-SVMP ".o/f'AJ'N
-G"o PUMP ROOM N9Z ~LOOR. g.L. 0'0" ,.7"0.::. _.;.'D, s"q. INv'. EiL.* 3~3""'-'-" DE:IONIZE~ Rod,M,V~.:; FLoO.'<. e:L. 0 -:;)
- i
_s.~5'::'J _/<f1?/~illL ,~'1 .*..J!J1>':"- i ~-~--'<J,cr
: tNY. r=./-, -,3-.e.
. I .J' ~_fb~.o." -;..~L._._. __ ~-=ti: ._,~. UJIj_/:::. r;, HgAT E)<'cHANG~r<. Rbp'M ri~ 4 under thiok FLOO<< EL. -0,'6 11..,"" PV.....,?~c:A.H'Af"~C, lconcrete walls .:1 'd' p~r~*se~p'*oo, ~raln" flot under/hltk wailS Il) 'I. \\lI. +--'-.-
- l r'-~~-------'i"i
.~ .i 'IBID l'rE!MS In , BLUI+/-.. dral!'Js, PUMP R0gt1 N~ I (ii'LOOR t!. 0 "0 ' CO\\JiUJU........ 'Ow 4)' I J sa~ PF.~e" l ~ :~::~~-:;:I~ (d~ ~' se:e: JJE:rA'L. /-FLD'~ ~ " L t.::; .....-\\. I e(t .~{ (1.-.-1 '5 3J m.,.. m \\
- D m
z --I,,' (") I m I I (") 4-"1{> UMP PIT Vf!-NT ~V!.') ". ~ ~ ~EiL"'i-'O *.,..y.'?U'NA-LLZ /4: E:!.-. -.5~4'* o ....-'2j/ fa..::::' WAL.!.. 'j' THRU ~I --;-+--'""- O~-t ',fI." .s;"Q._" ' (- _. ... ~ _ =::::::::::a..:._..__... /IN. E:L.<~;~" r,NV. L.-~;I .. j /" .:',A"o\\i*>i<>T "\\lI>,IN.. i I 8"...8""'1-' i£1!:..- d -/ - I : I r-\\ l;:z.f:::E/~ TO"'II /. "\\ i 4. _.-' I -. J 'J,., "q, 0:, "~'~~/~\\~~7j';:7-'."+'" I
- ~:">'}Ii'.'." /....
~ .. ~ "\\,... / ',: "'::::;' -..;'..-./ -r", 8' ... ~ - *
- g"<#
- '
1 ~' ~ ~ t 1--~r----:1-[ f,i ( 8"A8".-::4:"rEE T 4~ }J<.)... 't>-."
BSIILVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form Date: 3ab*tJ~ Time: -J~S~ Pipe ID#: C0 g, '3 Pipe Diameter: J.f II --:-"'::-'~~~-- --~---- Buildina: Ff Elevation: Type of Survey Investigation Characterization __ Final Survey /<J Other ~ Gross Co60 ~ Cs -- Detector ID# / Sled ID# L V5 - ( / I 0 ( Detector Cal Date: (.J. 5. 0 ~ DetectorCal Due Date: I' ;L S'. 0 1 Instrument: -,=~",-,,-<...3....:::.S-_O_~--'--l Instnunent ID #: 503 'I$F
- J..D 3 t-{.~ f Instrument Cal Date: I ~,a* () ~
Instrument Cal Due Date: I ~, ( t, tJ! From the Daily Pipe Survey Detector Control Form for the Selected Detector Background Value 3 cpm MDCRstatic q cpm Efficiency Factor for Pipe Diameter 0. 0 00 3 1 (from detector efficiency determination) 2 MDCstatic Z3l.tJ le dprn/ I 0-0 cm Is the MDCstatic acceptable? ~ No (ifno, adjust sample count time and recalculate MDCRstatic) Comments: 0;) tfe?{)~P,- pipe:( Ho I /--( 02 t-IOJ were. Cove ~tJf't') COWlPI-fly (JL1.f Technician Signature Pipe Interior Radiological Survey Position Feet into Pipe from Opening Count Time (min) Gross Counts Gross cpm Net cpm dprn/100cm2 1 I I do. J-(
- )..'1-(
/ 2 ~ /
- x,t
- .~
- JX'
/ 3
- 5
( JJ1 I? / 4 Y \\ 30 30 II../ V" 5 5 "\\ ( I: ( 6 6 6 \\ a~ clJ / /1 7 ') / ,~ ;, J ~ / 8 ~ ( I? If / V / 9 1 ) { r 18" 10 1O I
- 10
- l.D REFERENCE copy Package Page 1 of.3, Page 1
BSIILVSPipeCrawler-002 Revision 5 Pipe Interior Radiological Survey Form (Continuation Form) Date: 3 'd-b* 0 ~ Pipe ID#: Co R- :, Pipe Diameter: __tf,---(_( Access Point Area: fPff R¥'1 0 Building: P.£ ~ Elevation: 0 System: ED Position Feet into Pipe from Opening Count Time (min) Gross Counts Gross cpm Net cpm dpm/lOOcm2 11 II] r~ It.( If (:( 13 Ie{ ( / / f (0 I~ cAl 0<1 (0 Id. ~I .:z.1 /-/ (\\ /~ f7 I~ ('1
- ),,0
~l It) I~ (7 Il~ 11 JO JJ I I \\ \\ ~0 $..5' l, ,.7 ~Ji <*r'-~-~ '0 4"HD RI'E>E."'- ~ """- 5t~"'i""L @) tNV, El..:-l'-B\\' ,~ + O' 'L',I~<;;' '0 ~ ..L ',J ~~. .-~;....., r? V 1!' 'T.- -'Q '.., ".~~ ;: ~~<=-. -N PUMP ROOM N~~ ""I PLOQfi!..cL. O~O" 1TI "'LOOR I;L. 0'0" PUMP ROfM NS I .o-'ii---**--*--Z~-~ ..--r..D. I/J -:--.. -~- r c;....t;I'iV.IEL.S~O.. ~ h.......ACC(lJ'.,f b~'./IUC ~ I A6Qlllt"'..A'PRCA:f:Ij"$r"f!c:;."i l ..W: w.' .t;:I 8"' 1~o_:. PUMP <<OOM Ngz DE:IOfJIZEI<: RoJ,M,l/9 ~ FLo~-",I .J1 '-.--~~-,- I tNv'. !ZL,-3;d" "</0 ~.,*, "OS". mN':!!, S"q INv'. 6:L. - 3~3" ~ H§AT c~cH~NG~R ROO~1 dg~ FLOO(~ E:L. -olq" M )i"[OOR E.0-0 ' .. _. 1~()*. __ _ I* 'Il *1¥~noo~DRAIN (~.k-~ SE:S: DE-TAI'- I lJ) 'l. \\S. drain -001 under thick walls .-----~~~--,,'..; -I, ~ under thick concrete walls ..-v ~';;-.' /"
- '-"..~
~ M
""-<et--~
./rf)
- 6- --1:.
I I 41 " ~'Fi:O'~ . /......'i ~ L
- " Cr..~N-OUr- (C.O
- :
q .. '4-EL6I/. -a~q; INV.-, t ,I II -J~--VR.. i* + '1 ,q.:'+rflE =L.Jr.v,~3~/*INV. Vt:.Nr IVSE:R'(lIl<f 5E1!: XJE.'Arl.. 5 'IBID I'r~MS In i BLUE. drains
- I Q"
0.,;.- o~~, Cf~ z w cc w
- u.
w cc -~ .."0 I... -T 'h ""~_~:5'::'- >j.",p SUMP PiT 'Ie-NT ~6L ;O'-'--~WWALt J t EL.-5~4-'* THRU WAL.L ~--- .3:-C-b-1._ _ ('INV, L.-,3:r 1 /':.---t-*:.:" ~-\\ 4 * -... _- -4"q:: ;:2.1.:.;:,:1"0'-11 / ""\\ I (Q"j; o*/~.J,::c.ccr.:. ~ I \\' :) I , I I \\
- ~l
'\\"-\\"--;--~1;',_.- -;-- <t: L. -S".iJ."~ ,'\\ i' -, "'-u "'A~L 1 ~:
.. I;; ct- ;;' ~~~~r"~';,.;.,.~ ! :1* or; : ~ ( "R.1.j I-J _ _ _ _ __. _..J SIf}(.8 d X4."TEE j I I ,~~, ..~~...,J..,
BSIILVSPipeCrawler-002 Revision 6 Pipe Interior Radiological Survey Form Date: JI-d.-..()F;' Time: /J..jJ.lO I J '( C/ Pipe ID#:.....,f,..-'-=-'-LR_"---'--I Pipe Diameter: YT Access Point Area: PPII RI'Y/ 6 Building: PPH Elevation: 0 System: ---,-F~O'£..- D Type of Survey Investigation Characterization Final Survey t4 Other ~. Gross Co60 / Cs Detector ID# / Sled ID# Iv s-( / for Detector Cal Date: --<-/~~,-S'""----,,,rJ,---rL-- Detector Cal Due Date: I -).. S* tJ 1 ---'------=--=----=-----'------- Instrument: ~ -l-da.......<.5.=S---"'V'--------'( Instrument ID #:
1J~o_3'---H-'---"'-3 U-l Instrument Cal Date: -'..'1O"'-.-_f'-"6_'o_7 Instrument Cal Due Date:
(0 - (6 -cJ r
'---=------'-----~------
From the Daily Pipe Survey Detector Control Fonn for the Selected Detector Background Value '3'. 6 cpm MDCRstatic I 0 cpm (from detector efficiency detennination) 2 MDCstatic Is the MDCstatic acceptable? COre-Efficiency Factor for Pipe Diameter ----=._---=---'---- 2- "3 LA LP cm if no, adjust sample count time and recalculate J\\;IDCRslatic) Comments: J'l t ,SeR.. Su. fr/ev"!? ( 11-..,- £)( t2 ~ i ,7 Technician Signature Pipe Interior Radiological Survey Position Feet into Pipe from Opening Count Time (min) Gross Counts Gross cpm Net cpm dprn/lOOcm2 1 I I
- )1
~I / 2
- 2..
I,) I,S / 3 3 I /1 17 / 4 '1 I I~ /1. / 5 S 30 30 jlVA 6 h I d.--5 dA5--- / 7 / 8 ~ / 9 / 10 --- 1/ Package Page 1 ofcl. REFERENCE COpy, Page 1
I
- \\:1 h
- '6' __ *..J:'
FS~~ CpOF~;~~~;""IO~'r.-~-~I PUMp ROOM Ne I fl'lOOR. eL 0 30 ' 1~o*... I* nOo~ VRAIN (F.b~ 6E:S be.-rAlL. .1 PUMP ROOM {'/"2 "'LeaR. e.L 0'6" 1~.O.*:, .F.D. PU,'jP ROOM N~3 FLOOR. =L, O~O' ,":tTI1E
- £,,~". ~ 3~1'\\I'IV*.
.( ,..-\\. S 2J m " m'
- D m
Z o m (") o r~ I drain' 'not under thick !walls IBID l'rEMS In
- BLUIt - drains '
under thick concrete walts +------ I "'i.,. ~ 'C1>6!O:.
- i'NV. ';'£", -3~9" if-I ::::
3.::..-r~_.:_. HEAT E~cMANG~1C ROO~lde4 pclooR E:L. -0'-0"
- ~;~f.~~~J.~o'g.
'.....~
- s
0 ~ .~.:~ '--"~-I ~ I I, q."f /o'd. EL.-5'0" 51 ~A(,CC'J',J c/¥,JJut; ri1 I A&>,'6..A".roI(....:'"1t1~..i
- ..9t-tI.S:vht'P'C>>l"AIN ~.
_.,:;"~ --J J Ii)
- c.
8' 8")(.S"J( 4'r7-E.E~*--* _! '
- J 4 i to'
~...if, () ) ~ ~+ ~ . ~-FLOO"K} t * '0 4"~D R'E.R. " N "'- 5E(f)e,.,,,,... '" 1~V.'£:\\.o.~l'..B" ~ + OEk.I"~' ~ F,P. ..*01... 1iJ '--1... I I j
- I I I
I I:J "1' ~ i r-i i i I ( ~. .'.'-.}}