SEARCH UNIT PARAMETERS/CERTIFICATES The search unit documentation is presented on the following pages.
LINEARITY CHECK DATA SHEET Equipment / module :
OMNI-MX/OMNI-M-PA32128PR Serial number :
OMNI-Z-1012/OMNI-Z-6012 Calibration Due 11/21/08 Procedure :
TechDocE_OmniScanPA_SiteLinearityCheck_revA.doc Phased array probe:
MODEL-AS SN-5135 G106 Reference block:
MEUXE005A Verification:
PRE EXAMINATION Gain Gain Value EA EB EA/2 Setting (dB)
(%FSH)
(%FSH)
(%FSH)
Nominal Gain 7.7 40 20 20 Nominal Gain + 6 dB 13.3 76 37.6 18.8 Nominal Gain - 6 dB 1.7 20 10 10 Test OK / NOK Vertical Amplification Linearity OK Amplitude Control Linearity OK Data Analyst :
Jeff Devers LMT Review Todd Blechinger Date/Time :
Date :
EPRI Review Report #
EPRI-PA-04 Date :
Page 1 of 50 ANII Review N/A Date :
3/8/2008-1720 3/14/08 3/16/08
LINEARITY CHECK DATA SHEET Equipment / module :
OMNI-MX/OMNI-M-PA32128PR Serial number :
OMNI-Z-1012/OMNI-Z-6012 Calibration Due 21-Nov-08 Procedure :
TechDocE_OmniScanPA_SiteLinearityCheck_revA.doc Phased array probe:
MODEL-AS SN-5135 G106 Reference block:
MEUXE005A Verification:
POST EXAMINATION Gain Gain Value EA EB EA/2 Setting (dB)
(%FSH)
(%FSH)
(%FSH)
Nominal Gain 7.7 40 20 20 Nominal Gain + 6 dB 13.3 76 37.6 18.8 Nominal Gain - 6 dB 1.7 20 10 10 Test OK / NOK Vertical Amplification Linearity OK Amplitude Control Linearity OK Data Analyst :
Jeff Devers LMT Review Todd Blechinger Date/Time :
Date :
EPRI Review Report #
EPRI-PA-04 Date :
Page 2 of 50 ANII Review N/A Date :
3/13/2008-1700 3/14/08 3/16/08
Procedure :
ZETEC_Omniscan PA_03_revD Plant / Unit : PSL/1 UT equipment : OMNI-M-PA32128PR Ser. Number: OMNI-Z-1012/OMNI-Z-6012 Probe Serial No.
Active Wedge Calibration Reflector Sens.
UT path Date Time Status Operator Configuration Channels assembly block (dB)
(mm)
(dd/mm/yy)
(hh:mm)
(initials)
CS/ CIRCU TRL 270 5155A103 5155B105 ALL ADUXE 039A MEUXE015A 1.0" 32.5 35.6 3/12/08 1200 INITIAL CS/ CIRCU TRL 270 5155A103 5155B105 ALL ADUXE 039A MEUXE015A 1.0" 32.5 35.6 3/12/08 1915 FINAL CS/ CIRCD TRL 90 5155A103 5155B106 ALL ADUXE 039A MEUXE015A 1.0" 32.5 35.6 3/12/08 1150 INITIAL CS/ CIRCD TRL 90 5155A103 5155B106 ALL ADUXE 039A MEUXE015A 1.0" 32.5 35.6 3/12/08 1920 FINAL CS/ CIRCD TRS 90 5155A103 5155B106 ALL ADUXE 039A MEUXE015A 1.0" 28.5 35.6 3/13/08 1200 INITIAL CS/ CIRCD TRS 90 5155A103 5155B106 ALL ADUXE 039A MEUXE015A 1.0" 28.5 35.6 3/13/08 1355 FINAL CS/ CIRCU TRS 270 5155A103 5155B105 ALL ADUXE 039A MEUXE015A 1.0" 28.5 35.6 3/13/08 1125 INITIAL CS/ CIRCU TRS 270 5155A103 5155B105 ALL ADUXE 039A MEUXE015A 1.0" 28.5 35.6 3/13/08 1410 FINAL "Sens. (dB)" = gain setting (in dB) required to obtain echo amplitude of 80% SH on reference reflector Data Analyst :Jeff Devers LMT Review Todd Blechinger Date :
Date :
EPRI Review Report #
EPRI-PA-04 Date :
Page 3 of 50 ANII Review N/A Date :
3/16/08 PHASED ARRAY CALIBRATION DATA SHEET 3/13/08 3/14/08
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 4 of 50 Menu item Setting Essential / Non-Essential
/ Not applicable File File Destination Storage Card Non-Essential Save Mode A-Scan Essential File Name FPLSTL-SRNZL-D01_155MM_CIRCD TRL 90_AUTO_CS_ADUXE039A Essential Report Template Complete Non-Essential File Name FPLSTL-SRNZL-D01_155MM_CIRCD TRL 90_AUTO_CS_ADUXE039A Essential Paper Size Letter Non-Essential Format User field Off Non-Essential Probe Off Non-Essential Setup On Essential Note Off Non-Essential View Current Layout Non-Essential User field Not applicable Notes Not applicable Reading Result Selector List 1 Essential Field 1 A% (Peak Amplitude in Gate)
Essential Field 2 A^ (Half Path position in Gate)
Essential Field 3 B%
Not applicable Field 4 B^
Not applicable Cursors Not applicable Table Not applicable Export Not applicable Utilities Pref.
Units Millimeters Essential Bright (%)
25 Non-Essential Scheme Indoor Non-Essential System Clock Set Set to correct time Essential Date Set Set to correct date Essential Time Zone Set to correct time zone Non-Essential Daylight saving On Non-Essential Select Key F2 Non-Essential Assign Key Gain Non-Essential Service Not applicable
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 5 of 50 Options Not applicable Network Only for network saving Non-Essential UT General Gain 34.5 Essential Start 0
Essential Range 113.09mm Essential Wedge delay 2.30 Essential Velocity 5890 m/s Essential Pulser Pulser 1
Not applicable Tx/Rx mode PE Essential Freq 1.5 Essential Voltage High Essential PW Imported from LAW file (333 ns)
Essential PRF 25 Essential Receiver Receiver 1
Not applicable Filter None Essential Rectifier FW Essential Video Filter Off Essential Receiver Averaging 1
Essential Reject 0
Essential Beam Gain Offset Imported from LAW file Essential Scan Offset Imported from LAW file Essential Index Offset Imported from LAW file Essential Angle Imported from LAW file Essential Skew Imported from LAW file Essential Beam Delay Imported from LAW file Essential Advanced dB Ref Off Essential Points Qty 640 Essential Scale Factor 6
Essential Sum Gain Imported from LAW file Essential Scan Encoder Encoder 1 (Scan) 2 (Index)
Essential Polarity Normal Inverse Essential Type Quad Essential Resolution 35.38 58.00 Essential Origin 0
Essential Synchro
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 6 of 50 Source Both Axes Essential Scan Encoder 1 Essential Index Encoder 2 Not applicable Scan Speed 25 for scan resolution of 1 mm Not applicable Area Scan Start 0 mm 245 mm Essential Scan End 275mm 510 mm Scan Resolution 1.0 mm Essential Index start
-65.7 mm Essential Index end 36.8 mm Essential Index resolution 14.6 mm Essential Start Start Mode Reset All Essential Pause Off Non-Essential Data Storage Last Essential Display Selection Display A-S-C Essential C-Scan 1 A%
Non-Essential Group Current Non-Essential Projection On Not applicable Rulers UT Unit Sound Path Essential
% Ruler Linear(%)
Essential Grid Off Non-Essential DAC / TCG Off Essential Gate On Essential Cursor On Essential Zoom Not applicable Color Select Amplitude Essential Start (%)
0.0 Essential End (%)
100.0 Essential Properties Not applicable Probe/Part Select Group 1
Not applicable Group Link Off Not applicable Select Select Tx/Rx Essential Select Probe Unknown Not applicable Select Wedge Contact / Contact Not applicable Auto Detect Off Essential Scan Offset 0
Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 7 of 50 Index Offset 0
Essential Skew 0
Essential Characterize Not applicable Parts Not applicable Wizard Not applicable PGM Probe Configuration Group 1
Not applicable Enable Off Not applicable Scan Type Custom Essential Connection P 1
Not applicable Connection R 1
Not applicable Aperture Not applicable Beam Not applicable Laws Auto Program Off Essential Wizard Not applicable Gate/Alarm Gate Gate Select Gate A B
I Essential Gate Start 10 0
0 Essential Width End of time base 0
0 Non-Essential Threshold 25 0
0 Essential Mode Positive Not applicable Synchro Pulse Essential Alarms Not applicable Output Not applicable Gate/Alarm (ctd.)
DAC / TCG Not applicable Thickness Not applicable Calibration Phased Array Not applicable Axis Not applicable TCG Not applicable Code Not applicable User Gain Not applicable Start Not applicable Range Not applicable Display Not applicable Gate Not applicable
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 8 of 50 Focal Law Calculator Inputs Menu item Setting Essential / Non-Essential
/ Not applicable Probe (CS) 90° Name 1.5M16x2E32-7(EWUXE083A)
Essential Probe Skew Angle 90° Essential Probe Frequency 1.5 MHz Essential Number of elements on primary axis 16 Essential Primary axis pitch 2 mm Essential Secondary axis width 7 mm Essential Pitch and Catch Checked Essential Probe separation Not applicable Squint angle 0.0° Essential Reverse primary axis Unchecked Essential Specimen Name Memphis CS LW Non-Essential Specimen Type Pipe OD Essential Wave type Longitudinal for TRL Essential Sound velocity 90°-5890 m/s Essential Thickness 40 mm Essential Radius 77 mm Essential Wedge Name ADUXE039A Essential Footprint Curvature along secondary axis Essential Wedge angle 22.3 Essential Roof angle 6.0 Essential Sound velocity 2330 m/s Essential Height at the middle of the first element 8.17 mm for ADUXE039A Essential Primary axis offset of the middle of the first element 8.43 mm for ADUXE039A Essential Secondary axis offset of the middle of the first element 7.74 mm for ADUXE039A Essential Primary axis position of wedge reference
-50.00 mm Essential Secondary axis position of wedge reference
-15.00 mm Essential Wedge length 50.00 mm Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 9 of 50 Distance between contact points (wedge width) 30.00 mm Essential Scan Type Linear Essential Beam angles selection Primary steering angle Not applicable Secondary steering angle Not applicable Refracted angle 90°-30°,45°,60°,70° Essential Beam skew angle Not applicable Focal points selection Focusing type Auto Essential Focal plane position Not applicable Emission focus position Not applicable Reception focus position Not applicable Elements selection Improved resolution Checked Essential Pulser Start 1
Essential Pulser Stop 9
Essential Pulser Resolution 1
Essential Receiver Start 1
Essential Primary axis aperture 8
Essential Pulser connection 1
Essential Receiver connection 65 Essential Hardware selection Type OmniScan 32/128 Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 10 of 50 Menu item Setting Essential / Non-Essential
/ Not applicable File File Destination Storage Card Non-Essential Save Mode A-Scan Essential File Name FPLSTL-SRNZL-D01_155MM_CIRCU TRL 270_AUTO_CS_ADUXE039A Essential Report Template Complete Non-Essential File Name FPLSTL-SRNZL-D01_155MM_CIRCU TRL 270_AUTO_CS_ADUXE039A Essential Paper Size Letter Non-Essential Format User field Off Non-Essential Probe Off Non-Essential Setup On Essential Note Off Non-Essential View Current Layout Non-Essential User field Not applicable Notes Not applicable Reading Result Selector List 1 Essential Field 1 A% (Peak Amplitude in Gate)
Essential Field 2 A^ (Half Path position in Gate)
Essential Field 3 B%
Not applicable Field 4 B^
Not applicable Cursors Not applicable Table Not applicable Export Not applicable Utilities Pref.
Units Millimeters Essential Bright (%)
25 Non-Essential Scheme Indoor Non-Essential System Clock Set Set to correct time Essential Date Set Set to correct date Essential Time Zone Set to correct time zone Non-Essential Daylight saving On Non-Essential Select Key F2 Non-Essential Assign Key Gain Non-Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 11 of 50 Service Not applicable Options Not applicable Network Only for network saving Non-Essential UT General Gain 34.5 Essential Start 0
Essential Range 110.78 Essential Wedge delay 2.30 Essential Velocity 5770 m/s Essential Pulser Pulser 1
Not applicable Tx/Rx mode PE Essential Freq 1.5 Essential Voltage High Essential PW Imported from LAW file (333 ns)
Essential PRF 25 Essential Receiver Receiver 1
Not applicable Filter None Essential Rectifier FW Essential Video Filter Off Essential Receiver Averaging 1
Essential Reject 0
Essential Beam Gain Offset Imported from LAW file Essential Scan Offset Imported from LAW file Essential Index Offset Imported from LAW file Essential Angle Imported from LAW file Essential Skew Imported from LAW file Essential Beam Delay Imported from LAW file Essential Advanced dB Ref Off Essential Points Qty 640 Essential Scale Factor 6
Essential Sum Gain Imported from LAW file Essential Scan Encoder Encoder 1 (Scan) 2 (Index)
Essential Polarity Normal Inverse Essential Type Quad Essential Resolution 35.36 58.00 Essential Origin 0
Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 12 of 50 Synchro Source Both Axes Essential Scan Encoder 1 Essential Index Encoder 2 Not applicable Scan Speed 25 for scan resolution of 1 mm Not applicable Area Scan Start 0 mm 245 mm Essential Scan End 275 mm 510 mm Scan Resolution 1.0 mm Essential Index start
-41.8 mm Essential Index end 60.7 mm Essential Index resolution 14.6 mm Essential Start Start Mode Reset All Essential Pause Off Non-Essential Data Storage Last Essential Display Selection Display A-S-C Essential C-Scan 1 A%
Non-Essential Group Current Non-Essential Projection On Not applicable Rulers UT Unit Sound Path Essential
% Ruler Linear(%)
Essential Grid Off Non-Essential DAC / TCG Off Essential Gate On Essential Cursor On Essential Zoom Not applicable Color Select Amplitude Essential Start (%)
0.0 Essential End (%)
100.0 Essential Properties Not applicable Probe/Part Select Group 1
Not applicable Group Link Off Not applicable Select Select Tx/Rx Essential Select Probe Unknown Not applicable Select Wedge Contact / Contact Not applicable Auto Detect Off Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 13 of 50 Position Scan Offset 0
Essential Index Offset 0
Essential Skew 0
Essential Characterize Not applicable Parts Not applicable Wizard Not applicable PGM Probe Configuration Group 1
Not applicable Enable Off Not applicable Scan Type Custom Essential Connection P 1
Not applicable Connection R 1
Not applicable Aperture Not applicable Beam Not applicable Laws Auto Program Off Essential Wizard Not applicable Gate/Alarm Gate Gate Select Gate A B
I Essential Gate Start 10 0
0 Essential Width End of time base 0
0 Non-Essential Threshold 25 0
0 Essential Mode Positive Not applicable Synchro Pulse Essential Alarms Not applicable Output Not applicable Gate/Alarm (ctd.)
DAC / TCG Not applicable Thickness Not applicable Calibration Phased Array Not applicable Axis Not applicable TCG Not applicable Code Not applicable User Gain Not applicable Start Not applicable Range Not applicable Display Not applicable Gate Not applicable
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 14 of 50 Focal Law Calculator Inputs Menu item Setting Essential / Non-Essential
/ Not applicable Probe (CS) 270° Name 1.5M16x2E32-7(EWUXE083A)
Essential Probe Skew Angle 270° Essential Probe Frequency 1.5 MHz Essential Number of elements on primary axis 16 Essential Primary axis pitch 2 mm Essential Secondary axis width 7 mm Essential Pitch and Catch Checked Essential Probe separation Not applicable Squint angle 0.0° Essential Reverse primary axis Unchecked Essential Specimen Name Memphis SS LW Non-Essential Specimen Type Pipe OD Essential Wave type Longitudinal for TRL Essential Sound velocity 270°-5770 m/s Essential Thickness 40 mm Essential Radius 77 mm Essential Wedge Name ADUXE039A Essential Footprint Curvature along secondary axis Essential Wedge angle 22.3 Essential Roof angle 6.0 Essential Sound velocity 2330 m/s Essential Height at the middle of the first element 8.17 mm for ADUXE039A Essential Primary axis offset of the middle of the first element 8.43 mm for ADUXE039A Essential Secondary axis offset of the middle of the first element 7.74 mm for ADUXE039A Essential Primary axis position of wedge reference
-50.00 mm Essential Secondary axis position of wedge reference
-15.00 mm Essential Wedge length 50.00 mm Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 15 of 50 Distance between contact points (wedge width) 30.00 mm Essential Scan Type Linear Essential Beam angles selection Primary steering angle Not applicable Secondary steering angle Not applicable Refracted angle 270°-30°,45°,60°,70° Essential Beam skew angle Not applicable Focal points selection Focusing type Auto Essential Focal plane position Not applicable Emission focus position Not applicable Reception focus position Not applicable Elements selection Improved resolution Checked Essential Pulser Start 1
Essential Pulser Stop 9
Essential Pulser Resolution 1
Essential Receiver Start 1
Essential Primary axis aperture 8
Essential Pulser connection 1
Essential Receiver connection 65 Essential Hardware selection Type OmniScan 32/128 Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 16 of 50 Menu item Setting Essential / Non-Essential
/ Not applicable File File Destination Storage Card Non-Essential Save Mode A-Scan Essential File Name FPLSTL-SRNZL-D01_155MM_CIRCD TRS 90_AUTO_CS_ADUXE039A Essential Report Template Complete Non-Essential File Name FPLSTL-SRNZL-D01_155MM_CIRCD TRS 90_AUTO_CS_ADUXE039A Essential Paper Size Letter Non-Essential Format User field Off Non-Essential Probe Off Non-Essential Setup On Essential Note Off Non-Essential View Current Layout Non-Essential User field Not applicable Notes Not applicable Reading Result Selector List 1 Essential Field 1 A% (Peak Amplitude in Gate)
Essential Field 2 A^ (Half Path position in Gate)
Essential Field 3 B%
Not applicable Field 4 B^
Not applicable Cursors Not applicable Table Not applicable Export Not applicable Utilities Pref.
Units Millimeters Essential Bright (%)
25 Non-Essential Scheme Indoor Non-Essential System Clock Set Set to correct time Essential Date Set Set to correct date Essential Time Zone Set to correct time zone Non-Essential Daylight saving On Non-Essential Select Key F2 Non-Essential Assign Key Gain Non-Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 17 of 50 Service Not applicable Options Not applicable Network Only for network saving Non-Essential UT General Gain 28.5 Essential Start 0
Essential Range 116.28mm Essential Wedge delay 3.30 Essential Velocity 3230 m/s Essential Pulser Pulser 1
Not applicable Tx/Rx mode PE Essential Freq 1.5 Essential Voltage High Essential PW Imported from LAW file (333 ns)
Essential PRF 25 Essential Receiver Receiver 1
Not applicable Filter None Essential Rectifier FW Essential Video Filter Off Essential Receiver Averaging 1
Essential Reject 0
Essential Beam Gain Offset Imported from LAW file Essential Scan Offset Imported from LAW file Essential Index Offset Imported from LAW file Essential Angle Imported from LAW file Essential Skew Imported from LAW file Essential Beam Delay Imported from LAW file Essential Advanced dB Ref Off Essential Points Qty 800 Essential Scale Factor 9
Essential Sum Gain Imported from LAW file Essential Scan Encoder Encoder 1 (Scan) 2 (Index)
Essential Polarity Normal Inverse Essential Type Quad Essential Resolution 35.38 58.00 Essential Origin 0
Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 18 of 50 Synchro Source Both Axes Essential Scan Encoder 1 Essential Index Encoder 2 Not applicable Scan Speed 25 for scan resolution of 1 mm Not applicable Area Scan Start 0 mm Essential Scan End 510 mm Scan Resolution 1.0 mm Essential Index start
-70.2 mm Essential Index end
-14.3 mm Essential Index resolution 14.0 mm Essential Start Start Mode Reset All Essential Pause Off Non-Essential Data Storage Last Essential Display Selection Display A-S-C Essential C-Scan 1 A%
Non-Essential Group Current Non-Essential Projection On Not applicable Rulers UT Unit Sound Path Essential
% Ruler Linear(%)
Essential Grid Off Non-Essential DAC / TCG Off Essential Gate On Essential Cursor On Essential Zoom Not applicable Color Select Amplitude Essential Start (%)
0.0 Essential End (%)
100.0 Essential Properties Not applicable Probe/Part Select Group 1
Not applicable Group Link Off Not applicable Select Select Tx/Rx Essential Select Probe Unknown Not applicable Select Wedge Contact / Contact Not applicable Auto Detect Off Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 19 of 50 Scan Offset 0
Essential Index Offset 0
Essential Skew 0
Essential Characterize Not applicable Parts Not applicable Wizard Not applicable PGM Probe Configuration Group 1
Not applicable Enable Off Not applicable Scan Type Custom Essential Connection P 1
Not applicable Connection R 1
Not applicable Aperture Not applicable Beam Not applicable Laws Auto Program Off Essential Wizard Not applicable Gate/Alarm Gate Gate Select Gate A B
I Essential Gate Start 10 0
0 Essential Width End of time base 0
0 Non-Essential Threshold 25 0
0 Essential Mode Positive Not applicable Synchro Pulse Essential Alarms Not applicable Output Not applicable Gate/Alarm (ctd.)
DAC / TCG Not applicable Thickness Not applicable Calibration Phased Array Not applicable Axis Not applicable TCG Not applicable Code Not applicable User Gain Not applicable Start Not applicable Range Not applicable Display Not applicable Gate Not applicable
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 20 of 50 Focal Law Calculator Inputs Menu item Setting Essential / Non-Essential
/ Not applicable Probe (CS) 90° Name 1.5M16x2E32-7(EWUXE083A)
Essential Probe Skew Angle 90° Essential Probe Frequency 1.5 MHz Essential Number of elements on primary axis 16 Essential Primary axis pitch 2 mm Essential Secondary axis width 7 mm Essential Pitch and Catch Checked Essential Probe separation Not applicable Squint angle 0.0° Essential Reverse primary axis Unchecked Essential Specimen Name Memphis CS SW Non-Essential Specimen Type Pipe OD Essential Wave type Transverse for TRL Essential Sound velocity 90°-3230 m/s Essential Thickness 40 mm Essential Radius 77 mm Essential Wedge Name ADUXE039A Essential Footprint Curvature along secondary axis Essential Wedge angle 22.3 Essential Roof angle 6.0 Essential Sound velocity 2330 m/s Essential Height at the middle of the first element 8.17 mm for ADUXE039A Essential Primary axis offset of the middle of the first element 8.43 mm for ADUXE039A Essential Secondary axis offset of the middle of the first element 7.74 mm for ADUXE039A Essential Primary axis position of wedge reference
-50.00 mm Essential Secondary axis position of wedge reference
-15.00 mm Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 21 of 50 Wedge length 50.00 mm Essential Distance between contact points (wedge width) 30.00 mm Essential Scan Type Linear Essential Beam angles selection Primary steering angle Not applicable Secondary steering angle Not applicable Refracted angle 90°-45°,60° Essential Beam skew angle Not applicable Focal points selection Focusing type Auto Essential Focal plane position Not applicable Emission focus position Not applicable Reception focus position Not applicable Elements selection Improved resolution Checked Essential Pulser Start 1
Essential Pulser Stop 9
Essential Pulser Resolution 1
Essential Receiver Start 1
Essential Primary axis aperture 8
Essential Pulser connection 1
Essential Receiver connection 65 Essential Hardware selection Type OmniScan 32/128 Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 22 of 50 Menu item Setting Essential / Non-Essential
/ Not applicable File File Destination Storage Card Non-Essential Save Mode A-Scan Essential File Name FPLSTL-SRNZL-D01_155MM_CIRCU TRS 270_AUTO_CS_ADUXE039A Essential Report Template Complete Non-Essential File Name FPLSTL-SRNZL-D01_155MM_CIRCU TRS 270_AUTO_CS_ADUXE039A Essential Paper Size Letter Non-Essential Format User field Off Non-Essential Probe Off Non-Essential Setup On Essential Note Off Non-Essential View Current Layout Non-Essential User field Not applicable Notes Not applicable Reading Result Selector List 1 Essential Field 1 A% (Peak Amplitude in Gate)
Essential Field 2 A^ (Half Path position in Gate)
Essential Field 3 B%
Not applicable Field 4 B^
Not applicable Cursors Not applicable Table Not applicable Export Not applicable Utilities Pref.
Units Millimeters Essential Bright (%)
25 Non-Essential Scheme Indoor Non-Essential System Clock Set Set to correct time Essential Date Set Set to correct date Essential Time Zone Set to correct time zone Non-Essential Daylight saving On Non-Essential Select Key F2 Non-Essential Assign Key Gain Non-Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 23 of 50 Service Not applicable Options Not applicable Network Only for network saving Non-Essential UT General Gain 28.5 Essential Start 0
Essential Range 113.40 mm Essential Wedge delay 3.30 Essential Velocity 3150 m/s Essential Pulser Pulser 1
Not applicable Tx/Rx mode PE Essential Freq 1.5 Essential Voltage High Essential PW Imported from LAW file (333 ns)
Essential PRF 25 Essential Receiver Receiver 1
Not applicable Filter None Essential Rectifier FW Essential Video Filter Off Essential Receiver Averaging 1
Essential Reject 0
Essential Beam Gain Offset Imported from LAW file Essential Scan Offset Imported from LAW file Essential Index Offset Imported from LAW file Essential Angle Imported from LAW file Essential Skew Imported from LAW file Essential Beam Delay Imported from LAW file Essential Advanced dB Ref Off Essential Points Qty 800 Essential Scale Factor 9
Essential Sum Gain Imported from LAW file Essential Scan Encoder Encoder 1 (Scan) 2 (Index)
Essential Polarity Normal Inverse Essential Type Quad Essential Resolution 35.38 58.00 Essential Origin 0
Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 24 of 50 Synchro Source Both Axes Essential Scan Encoder 1 Essential Index Encoder 2 Not applicable Scan Speed 25 for scan resolution of 1 mm Not applicable Area Scan Start 0 mm Essential Scan End 510 mm Scan Resolution 1.0 mm Essential Index start 9.3 mm Essential Index end 65.2 mm Essential Index resolution 14.0 mm Essential Start Start Mode Reset All Essential Pause Off Non-Essential Data Storage Last Essential Display Selection Display A-S-C Essential C-Scan 1 A%
Non-Essential Group Current Non-Essential Projection On Not applicable Rulers UT Unit Sound Path Essential
% Ruler Linear(%)
Essential Grid Off Non-Essential DAC / TCG Off Essential Gate On Essential Cursor On Essential Zoom Not applicable Color Select Amplitude Essential Start (%)
0.0 Essential End (%)
100.0 Essential Properties Not applicable Probe/Part Select Group 1
Not applicable Group Link Off Not applicable Select Select Tx/Rx Essential Select Probe Unknown Not applicable Select Wedge Contact / Contact Not applicable Auto Detect Off Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 25 of 50 Scan Offset 0
Essential Index Offset 0
Essential Skew 0
Essential Characterize Not applicable Parts Not applicable Wizard Not applicable PGM Probe Configuration Group 1
Not applicable Enable Off Not applicable Scan Type Custom Essential Connection P 1
Not applicable Connection R 1
Not applicable Aperture Not applicable Beam Not applicable Laws Auto Program Off Essential Wizard Not applicable Gate/Alarm Gate Gate Select Gate A B
I Essential Gate Start 10 0
0 Essential Width End of time base 0
0 Non-Essential Threshold 25 0
0 Essential Mode Positive Not applicable Synchro Pulse Essential Alarms Not applicable Output Not applicable Gate/Alarm (ctd.)
DAC / TCG Not applicable Thickness Not applicable Calibration Phased Array Not applicable Axis Not applicable TCG Not applicable Code Not applicable User Gain Not applicable Start Not applicable Range Not applicable Display Not applicable Gate Not applicable
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 26 of 50 Focal Law Calculator Inputs Menu item Setting Essential / Non-Essential
/ Not applicable Probe (CS) 270° Name 1.5M16x2E32-7(EWUXE083A)
Essential Probe Skew Angle 270° Essential Probe Frequency 1.5 MHz Essential Number of elements on primary axis 16 Essential Primary axis pitch 2 mm Essential Secondary axis width 7 mm Essential Pitch and Catch Checked Essential Probe separation Not applicable Squint angle 0.0° Essential Reverse primary axis Unchecked Essential Specimen Name Memphis SS SW Non-Essential Specimen Type Pipe OD Essential Wave type Transverse for TRL Essential Sound velocity 270°-3150 m/s Essential Thickness 40 mm Essential Radius 77 mm Essential Wedge Name ADUXE039A Essential Footprint Curvature along secondary axis Essential Wedge angle 22.3 Essential Roof angle 6.0 Essential Sound velocity 2330 m/s Essential Height at the middle of the first element 8.17 mm for ADUXE039A Essential Primary axis offset of the middle of the first element 8.43 mm for ADUXE039A Essential Secondary axis offset of the middle of the first element 7.74 mm for ADUXE039A Essential Primary axis position of wedge reference
-50.00 mm Essential Secondary axis position of wedge reference
-15.00 mm Essential
OMNISCAN PHASED ARRAY INSTRUMENT SETTINGS WELD # FPLSTL-SRNZL-D01 Report# EPRI-PA-04 Page 27 of 50 Wedge length 50.00 mm Essential Distance between contact points (wedge width) 30.00 mm Essential Scan Type Linear Essential Beam angles selection Primary steering angle Not applicable Secondary steering angle Not applicable Refracted angle 270°-45°,60° Essential Beam skew angle Not applicable Focal points selection Focusing type Auto Essential Focal plane position Not applicable Emission focus position Not applicable Reception focus position Not applicable Elements selection Improved resolution Checked Essential Pulser Start 1
Essential Pulser Stop 9
Essential Pulser Resolution 1
Essential Receiver Start 1
Essential Primary axis aperture 8
Essential Pulser connection 1
Essential Receiver connection 65 Essential Hardware selection Type OmniScan 32/128 Essential
Report# EPRI-PA-04 Page 28 of 50
OmniScan Report Report Date Report Version Setup File name Date of Inspection Inspection Version Save Mode 2008 / 03 / 12 1.4R3 FPLSTL-SRNZL-D01_155MM_CIRCD TRL 90_AUTO_CS_ADUXE039A.opd 2008 / 03 / 12 1.4R3 A Scan OmniScan Type OmniScan Serial #
Module Type Module Serial #
Calibration Due Data File name OmniScan MX OMNI-Z-1012 OMNI-M-PA32128PR OMNI-Z-6012 2008 / 11 / 21 FPLSTL-SRNZL-D01_155MM_CIRCD TRL 90_AUTO_CS_ADUXE039A Group 1 Setup A:30.0 Sk:090 L:001 Beam Delay Start (Half Path)
Range (Half Path)
PRF Type Averaging Factor 12.10 us
-0.02 mm 113.09 mm 25 PA 1
Scale Type Scale Factor Video Filter Pretrig Rectification Band Pass Filter Compression 6
Off 0.00 µs FW None (0.52 - 19 MHz)
Voltage Gain Mode Wave Type Sound Velocity Pulse Width High 34.50 dB PC (Pitch And Catch)
User Defined 5890.0 m/s 332.50 ns Scan Offset Index Offset Skew 0.00 mm 0.00 mm N/A Gate Start Width Threshold Synchro I
0.04 mm 1.00 mm 0.00 %
Pulse A
10.23 mm 122.48 mm 25.00 %
Pulse B
0.04 mm 1.00 mm 0.00 %
Pulse Law Law File name Scan Type DM_155_CIRCD TRL 90_AUTO_CS_ADUXE039A.law Custom Part Material Geometry Thickness STEEL MILD Plate 50.00 mm Scan Area Scan Start Scan Length Scan Resolution Index Start Index Length Index Resolution 0.00 mm 275.00 mm 1.00 mm
-65.70 mm 102.20 mm 14.60 mm Synchro Max Scan Speed Both Axis 25.00 mm/s Axis Encoder Encoder Type Encoder Resolution Polarity Scan 1
Quadrature 35.36 step/mm Normal Index 2
Quadrature 58.00 step/mm Inverse A%
A^
B%
B^
None None None None 4.3 %
--- mm 2.7 %
0.10 mm
Report# EPRI-PA-04 Page 29 of 50
Todd P. Blechinger Technician Name Technician Signature LMTINC.
Contractor 3/12/08 Date
Report# EPRI-PA-04 Page 30 of 50
OmniScan Report Report Date Report Version Setup File name Date of Inspection Inspection Version Save Mode 2008 / 03 / 12 1.4R3 FPLSTL-SRNZL-D01_155MM_CIRCD TRL 90_AUTO_CS_ADUXE039A245TO510.opd 2008 / 03 / 12 1.4R3 A Scan OmniScan Type OmniScan Serial #
Module Type Module Serial #
Calibration Due Data File name OmniScan MX OMNI-Z-1012 OMNI-M-PA32128PR OMNI-Z-6012 2008 / 11 / 21 FPLSTL-SRNZL-D01_155MM_CIRCD TRL 90_AUTO_CS_ADUXE039A245TO510 Group 1 Setup A:30.0 Sk:090 L:001 Beam Delay Start (Half Path)
Range (Half Path)
PRF Type Averaging Factor 12.10 us
-0.02 mm 113.09 mm 25 PA 1
Scale Type Scale Factor Video Filter Pretrig Rectification Band Pass Filter Compression 6
Off 0.00 µs FW None (0.52 - 19 MHz)
Voltage Gain Mode Wave Type Sound Velocity Pulse Width High 34.50 dB PC (Pitch And Catch)
User Defined 5890.0 m/s 332.50 ns Scan Offset Index Offset Skew 0.00 mm 0.00 mm N/A Gate Start Width Threshold Synchro I
0.04 mm 1.00 mm 0.00 %
Pulse A
10.23 mm 122.48 mm 25.00 %
Pulse B
0.04 mm 1.00 mm 0.00 %
Pulse Law Law File name Scan Type DM_155_CIRCD TRL 90_AUTO_CS_ADUXE039A.law Custom Part Material Geometry Thickness STEEL MILD Plate 50.00 mm Scan Area Scan Start Scan Length Scan Resolution Index Start Index Length Index Resolution 245.00 mm 265.00 mm 1.00 mm
-65.70 mm 102.20 mm 14.60 mm Synchro Max Scan Speed Both Axis 25.00 mm/s Axis Encoder Encoder Type Encoder Resolution Polarity Scan 1
Quadrature 35.36 step/mm Normal Index 2
Quadrature 58.00 step/mm Inverse A%
A^
B%
B^
None None None None 6.3 %
--- mm 1.2 %
0.07 mm
Report# EPRI-PA-04 Page 31 of 50
Todd P. Blechinger Technician Name Technician Signature LMT INC.
Contractor 3/12/08 Date
Report# EPRI-PA-04 Page 32 of 50
OmniScan Report Report Date Report Version Setup File name Date of Inspection Inspection Version Save Mode 2008 / 03 / 12 1.4R3 FPLSTL-SRNZL-D01_155MM_CIRCU TRL 270_AUTO_CS_ADUXE039A.opd 2008 / 03 / 12 1.4R3 A Scan OmniScan Type OmniScan Serial #
Module Type Module Serial #
Calibration Due Data File name OmniScan MX OMNI-Z-1012 OMNI-M-PA32128PR OMNI-Z-6012 2008 / 11 / 21 FPLSTL-SRNZL-D01_155MM_CIRCU TRL 270_AUTO_CS_ADUXE039A Group 1 Setup A:30.0 Sk:270 L:001 Beam Delay Start (Half Path)
Range (Half Path)
PRF Type Averaging Factor 12.08 us
-0.02 mm 110.78 mm 25 PA 1
Scale Type Scale Factor Video Filter Pretrig Rectification Band Pass Filter Compression 6
Off 0.00 µs FW None (0.52 - 19 MHz)
Voltage Gain Mode Wave Type Sound Velocity Pulse Width High 34.50 dB PC (Pitch And Catch)
User Defined 5770.0 m/s 332.50 ns Scan Offset Index Offset Skew 0.00 mm 0.00 mm N/A Gate Start Width Threshold Synchro I
0.02 mm 0.98 mm 0.00 %
Pulse A
10.00 mm 119.99 mm 25.00 %
Pulse B
0.02 mm 0.98 mm 0.00 %
Pulse Law Law File name Scan Type DM_155_CIRCU TRL 270_AUTO_CS_ADUXE039A.law Custom Part Material Geometry Thickness STEEL MILD Plate 50.00 mm Scan Area Scan Start Scan Length Scan Resolution Index Start Index Length Index Resolution 0.00 mm 275.00 mm 1.00 mm
-41.80 mm 102.20 mm 14.60 mm Synchro Max Scan Speed Both Axis 25.00 mm/s Axis Encoder Encoder Type Encoder Resolution Polarity Scan 1
Quadrature 35.36 step/mm Normal Index 2
Quadrature 58.00 step/mm Inverse A%
A^
B%
B^
None None None None 6.3 %
--- mm 1.6 %
0.19 mm
Report# EPRI-PA-04 Page 33 of 50
Todd P. Blechinger Technician Name Technician Signature LMT INC.
Contractor 3/12/08 Date
Report# EPRI-PA-04 Page 34 of 50
OmniScan Report Report Date Report Version Setup File name Date of Inspection Inspection Version Save Mode 2008 / 03 / 12 1.4R3 FPLSTL-SRNZL-D01_155MM_CIRCU TRL 270_AUTO_CS_ADUXE039A_245TO510.opd 2008 / 03 / 12 1.4R3 A Scan OmniScan Type OmniScan Serial # Module Type Module Serial #
Calibration Due Data File name OmniScan MX OMNI-Z-1012 OMNI-M-PA32128PR OMNI-Z-6012 2008 / 11 / 21 FPLSTL-SRNZL-D01_155MM_CIRCU TRL 270_AUTO_CS_ADUXE039A_245TO510 Group 1 Setup A:30.0 Sk:270 L:001 Beam Delay Start (Half Path)
Range (Half Path)
PRF Type Averaging Factor 12.08 us
-0.02 mm 110.78 mm 25 PA 1
Scale Type Scale Factor Video Filter Pretrig Rectification Band Pass Filter Compression 6
Off 0.00 µs FW None (0.52 - 19 MHz)
Voltage Gain Mode Wave Type Sound Velocity Pulse Width High 34.50 dB PC (Pitch And Catch)
User Defined 5770.0 m/s 332.50 ns Scan Offset Index Offset Skew 0.00 mm 0.00 mm N/A Gate Start Width Threshold Synchro I
0.02 mm 0.98 mm 0.00 %
Pulse A
10.00 mm 119.99 mm 25.00 %
Pulse B
0.02 mm 0.98 mm 0.00 %
Pulse Law Law File name Scan Type DM_155_CIRCU TRL 270_AUTO_CS_ADUXE039A.law Custom Part Material Geometry Thickness STEEL MILD Plate 50.00 mm Scan Area Scan Start Scan Length Scan Resolution Index Start Index Length Index Resolution 245.00 mm 265.00 mm 1.00 mm
-41.80 mm 102.20 mm 14.60 mm Synchro Max Scan Speed Both Axis 25.00 mm/s Axis Encoder Encoder Type Encoder Resolution Polarity Scan 1
Quadrature 35.36 step/mm Normal Index 2
Quadrature 58.00 step/mm Inverse A%
A^
B%
B^
None None None None 6.7 %
--- mm 1.2 %
0.02 mm
Report# EPRI-PA-04 Page 35 of 50
Todd P. Blechinger Technician Name Technician Signature LMT INC.
Contractor 3/12/08 Date
Report# EPRI-PA-04 Page 36 of 50
OmniScan Report Report Date Report Version Setup File name Date of Inspection Inspection Version Save Mode 2008 / 03 / 13 1.4R3 FPLSTL-SRNZL-D01_155MM_CIRCD TRS 90_AUTO_CS_ADUXE039A.opd 2008 / 03 / 13 1.4R3 A Scan OmniScan Type OmniScan Serial #
Module Type Module Serial #
Calibration Due Data File name OmniScan MX OMNI-Z-1012 OMNI-M-PA32128PR OMNI-Z-6012 2008 / 11 / 21 FPLSTL-SRNZL-D01_155MM_CIRCD TRS 90_AUTO_CS_ADUXE039A Group 1 Setup A:45.0 Sk:090 L:001 Beam Delay Start (Half Path)
Range (Half Path)
PRF Type Averaging Factor 13.96 us
-0.01 mm 116.28 mm 25 PA 1
Scale Type Scale Factor Video Filter Pretrig Rectification Band Pass Filter Compression 9
Off 0.00 µs FW None (0.52 - 19 MHz)
Voltage Gain Mode Wave Type Sound Velocity Pulse Width High 28.50 dB PC (Pitch And Catch)
User Defined 3230.0 m/s 332.50 ns Scan Offset Index Offset Skew 0.00 mm 0.00 mm N/A Gate Start Width Threshold Synchro I
0.02 mm 0.55 mm 0.00 %
Pulse A
5.61 mm 67.17 mm 25.00 %
Pulse B
0.02 mm 0.55 mm 0.00 %
Pulse Law Law File name Scan Type DM_155_CIRCD TRS 90_AUTO_CS_ADUXE039A.law Custom Part Material Geometry Thickness STEEL MILD Plate 50.00 mm Scan Area Scan Start Scan Length Scan Resolution Index Start Index Length Index Resolution 0.00 mm 510.00 mm 1.00 mm
-70.20 mm 56.00 mm 14.00 mm Synchro Max Scan Speed Both Axis 25.00 mm/s Axis Encoder Encoder Type Encoder Resolution Polarity Scan 1
Quadrature 35.36 step/mm Normal Index 2
Quadrature 58.00 step/mm Inverse A%
A^
B%
B^
None None None None 1.6 %
--- mm 0.8 %
0.05 mm
Report# EPRI-PA-04 Page 37 of 50
Todd P. Blechinger Technician Name Technician Signature LMT INC.
Contractor 3/13/08 Date
Report# EPRI-PA-04 Page 38 of 50
OmniScan Report Report Date Report Version Setup File name Date of Inspection Inspection Version Save Mode 2008 / 03 / 13 1.4R3 FPLSTL-SRNZL-D01_155MM_CIRCU TRS 270_AUTO_CS_ADUXE039A.opd 2008 / 03 / 13 1.4R3 A Scan OmniScan Type OmniScan Serial #
Module Type Module Serial #
Calibration Due Data File name OmniScan MX OMNI-Z-1012 OMNI-M-PA32128PR OMNI-Z-6012 2008 / 11 / 21 FPLSTL-SRNZL-D01_155MM_CIRCU TRS 270_AUTO_CS_ADUXE039A Group 1 Setup A:45.0 Sk:270 L:001 Beam Delay Start (Half Path)
Range (Half Path)
PRF Type Averaging Factor 14.14 us
-0.01 mm 113.40 mm 25 PA 1
Scale Type Scale Factor Video Filter Pretrig Rectification Band Pass Filter Compression 9
Off 0.00 µs FW None (0.52 - 19 MHz)
Voltage Gain Mode Wave Type Sound Velocity Pulse Width High 28.50 dB PC (Pitch And Catch)
User Defined 3150.0 m/s 332.50 ns Scan Offset Index Offset Skew 0.00 mm 0.00 mm N/A Gate Start Width Threshold Synchro I
0.02 mm 0.54 mm 0.00 %
Pulse A
10.01 mm 113.76 mm 25.00 %
Pulse B
0.02 mm 0.54 mm 0.00 %
Pulse Law Law File name Scan Type DM_155_CIRCU TRS 270_AUTO_CS_ADUXE039A.law Custom Part Material Geometry Thickness STEEL MILD Plate 50.00 mm Scan Area Scan Start Scan Length Scan Resolution Index Start Index Length Index Resolution 0.00 mm 510.00 mm 1.00 mm 9.30 mm 56.00 mm 14.00 mm Synchro Max Scan Speed Both Axis 25.00 mm/s Axis Encoder Encoder Type Encoder Resolution Polarity Scan 1
Quadrature 35.36 step/mm Normal Index 2
Quadrature 58.00 step/mm Inverse A%
A^
B%
B^
None None None None 22.7 %
--- mm 1.6 %
0.03 mm
Report# EPRI-PA-04 Page 39 of 50
Todd P. Blechinger Technician Name Technician Signature LMT INC.
Contractor 3/13/08 Date
SCAN PLAN Procedure :
ZETEC_OmniScanPA_03_revD Pipe Thickness T :
40.0 mm Plant / Unit :
Memphis Pipe OD :
154.0 mm Weld Id. :
FPLSTL-SRNZL-D01 Weld Extent Pipe Side Wp :
16.5 mm Dual Side Access : yes Weld Extent Nozzle Side Wn :
21.5 mm Complete Pipe:
yes Access Limitation Pipe Side Lp :
118.0 mm Access Limitation Nozzle Side Ln 127.0 mm Weld Length:
484.0 mm SCANNING SEQUENCES CIRCUMFERENTIAL FLAWS Focal law group MinTB MaxTB Scan Index Start End Resol.
Start End Resol.
- Lines Done ?
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(OK / NA)
CIRCD TRL 90 CS 100.0 125.0 640 0.0 508.8 1.0
-65.7 36.8 14.6 8
OK CIRCU TRL 270 CS 100.0 125.0 640 0.0 508.8 1.0
-41.8 60.7 14.6 8
OK CIRCD TRS 90 CS 100.0 125.0 800 0.0 508.8 1.0
-70.2
-14.3 14.0 5
OK CIRCU TRS 270 CS 100.0 125.0 800 0.0 508.8 1.0 9.3 65.2 14.0 5
OK SCANNING SEQUENCES AXIAL FLAWS Focal law group MinTB MaxTB Scan Index Start End Resol.
Start End Resol.
- Lines (mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
AX TRL 0 NA AX TRL 180 NA AX TRS 0 NA AX TRS 180 NA AX TRL 0 NA AX TRL 180 NA Data Analyst : Jeff Devers LMT Review Todd Blechinger Date :
Date :
EPRI Review Report #
EPRI-PA-04 Date :
Page 40 of 50 ANII Review N/A Date :
Probe Type Probe Type
- Data Points
- Data Points 3/14/08 3/16/08 3/12/08 Pipe OD Wp Wn Index Scan USound CIRCU TRL 270 CIRCU TRS 270 CIRCD TRL 90 CIRCD TRS 90 AX TRL 0 AX TRL 180 PIPE NOZZLE AX TRS 180 AX TRS 0 T
50 III OmniScan Software Version OmniScanConverter Software Version UltraVision Software Revision Level III Level III 3/16/08 ANII REVIEW / DATE N/A of 41 Technique Referencing System Level Level Todd Blechinger RI-See Attached FPLSTL-SRNZL-D01_155MM_CIRCU TRS 90_AUTO_CS_ADUXE039A Page Todd Blechinger RI-See Attached FPLSTL-SRNZL-D01_155MM_CIRCD TRL 90_AUTO_CS_ADUXE039A RI-See Attached FPLSTL-SRNZL-D01_155MM_CIRCU TRL 270_AUTO_CS_ADUXE039A RI-See Attached FPLSTL-SRNZL-D01_155MM_CIRCU TRS 270_AUTO_CS_ADUXE039A EPRI-PA-04 Results Data File Identification rev.D 1.4R3 1.7R5 1.1Q5 Acquisition Tech.
Zetec_ OmniScanPA_03 EPRI REVIEW / DATE Data Analyst Date 3/13/2008 Jeff Devers Report #
Date 3/14/2008 See attached Phased Array Indication Data Tabulation Sheet for indication information.
LMT Review Focal Law Group Used CIRCD TRL 90 CIRCU TRL 270 Revision#
Procedure No.
Comments:
CIRCD TRS 90 CIRCU TRS 270 Plant / Unit Comp / System Component Temp.
Ultrasonic Phased Array Examination Report EPRI FPLSTL-SRNZL-D01 64° Acquisition Tech.
Page Report #
EPRI-PA-04 PLANT/ UNIT COMP / SYSTEM PROCEDURE NO.
REV / CHANGE NO.
LMT REVIEW / LEVEL Level III Further Evaluation Required?
Yes x
No 3/16/08 ANII REVIEW / DATE EPRI9i REVIEW / DATE Used CIRCU TRL 270(Flaw #1), & CIRCD TRL 90(Flaw #2), Focal Law groups for final length and depth sizing results based on flaw locations in weld material.
Comments:
Circ. Flaw Data Analyst J.L. Devers Date 3/10/2008 48&50 of 50
.5" 47&49 of 50 2
FPLSTL-SRNZL-D01_155MM_CIRCD TRS 90_AUTO_CS_
ADUXE039A CIRCD TRS 90 13.0" 15.0" 2.0"
.3" 1.3" N/A
.3" 1.3" N/A Circ. Flaw
.25" Circ. Flaw 1.4" N/A 44&46 of 50 2
FPLSTL-SRNZL-D01_155MM_CIRCD TRL 90_AUTO_CS_
ADUXE039A245to510 CIRCD TRL 90 14.0" 16.0" 2.0"
.5" N/A
.25" 43&45 of 50 1
FPLSTL-SRNZL-D01_155MM_CIRCU TRS 270_AUTO_CS_
ADUXE039A CIRCU TRS 270 8.3" 9.9" 1.6"
.2" Circ. Flaw 1
FPLSTL-SRNZL-D01_155MM_CIRCU TRL 270_AUTO_CS_
ADUXE039A CIRCU TRL 270 7.9" 9.9" 2.0"
.4" 1.2" Evaluation /
Comments Printout Page #
Start (L1)
Stop (L2)
Length T.W. Depth Remain. Ligament T.W. %
Upstream Dnstream rev.D WELD LENGTH 19.05" IND. #
Data File Merged Data Group Used Length Sizing Information WELD CROWN WIDTH 1.50" Thru Wall Sizing Information Indication Position of 50 Phased Array Indication Tabulation Sheet DATA ANALYST / LEVEL J.L. Devers / III T.P. Blechinger / III FPLSTL-SRNZL-D01 COMP THICKNESS 1.60" Zetec_ OmniScanPA_03 REFERENCE LOCATION 0 Stamp / Weld Centerline 42 EPRI
Level III Level III Report# EPRI-PA-04 of 50 T.P. Blechinger 43 Page LMT Review Data Analyst EPRI Review ANII Review J. L. Devers
Level III Level III Report# EPRI-PA-04 of 50 LMT Review Data Analyst EPRI Review ANII Review J. L. Devers T.P. Blechinger 44 Page
Level III Level III Report# EPRI-PA-04 of 50 T.P. Blechinger 45 Page LMT Review Data Analyst EPRI Review ANII Review J. L. Devers
Level III Level III Report# EPRI-PA-04 of 50 LMT Review Data Analyst EPRI Review ANII Review J. L. Devers T.P. Blechinger 46 Page
Level III Level III Report# EPRI-PA-04 of 50 T.P. Blechinger 47 Page LMT Review Data Analyst EPRI Review ANII Review J. L. Devers
Level III Level III Report# EPRI-PA-04 of 50 LMT Review Data Analyst EPRI Review ANII Review J. L. Devers T.P. Blechinger 48 Page
Level III Level III Report# EPRI-PA-04 of 50 T.P. Blechinger 49 Page LMT Review Data Analyst EPRI Review ANII Review J. L. Devers
Level III Level III Report# EPRI-PA-04 of 50 LMT Review Data Analyst EPRI Review ANII Review J. L. Devers T.P. Blechinger 50 Page
OD:
ID:
OD Circ.:
ID Circ.:
Nom "T":
Ref. Face to CL DNST Side:
Ref. Face to CL UPST Side:
6.06 2.94 19.04 9.22 1.56 7.08 4.31 J.Devers Information:
IND# 1 IND# 2 IND# 3 IND# 4 IND# 5 IND# 6 IND# 7 Start(X1) 7.900 14.000 Stop(X2) 9.900 16.000 Y Start 0.100 0.400 Y Stop 0.100 0.400 Length 0.000 2.000 2.000 0.000 R.L.
1.200 1.260 As-Built Information:
Start(X1) 2.333 8.144 14.572 18.677 Stop(X2) 2.333 10.484 16.539 18.677 Y Start
-0.181 0.067 0.559 0.079 Y Stop 0.327 0.067 0.559 0.591 Length 0.508 2.341 1.967 0.512 R.L.
1.262 1.252 1.252 1.256 Deviations:
Length
-0.341 0.033 R.L.
-0.052 0.008 J. Devers Indication Report Sample ID:
FPLSTL-SRZNL-D01
-2.00
-1.50
-1.00
-0.50 0.00 0.50 1.00 1.50 2.00 0
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 C.L.
Flow Pipe/Safe-End Examination Side:
Notes: Only axial scans were analyzed looking for circumferential flaws.