ML080810431

From kanterella
Jump to navigation Jump to search
Part 21 Report Involving Potential Failure of Certain Rosemount Pressure Transmitters
ML080810431
Person / Time
Site: Vermont Yankee, Robinson, Cook, Quad Cities  
Issue date: 03/20/2008
From: Darrell Roberts
Rosemount Nuclear Instruments
To:
Office of Nuclear Reactor Regulation
References
Download: ML080810431 (10)


Text

0312012008 U.S. Nuclear Regulatory Commission Operations Center Event Report Page I General Information or Other (PAR)

Event#

44082 Rep Org: ROSEMOUNT NUCLEAR INSTRUMENTS, INC. Notification Date / Time: 03/20/2008 12:32 (EST)

Supplier: ROSEMOUNT NUCLEAR INSTRUMENTS, INC.

Event Date / Time: 03/20/2008 (CDT)

Last Modification: 03/20/2008 Region:

3 Docket #:

City: CHANHASSEN Agreement State: Yes County:

License #:

State: MN NRC Notified by: DAVID T. ROBERTS Notifications: STEVE ORTH R3 HQ Ops Officer: STEVE SANDIN MIKE ERNSTES R2 Emergency Class: NON EMERGENCY NEIL PERRY R1 10 CFR Section:

VERNE HODGE NRR 21.21 UNSPECIFIED PARAGRAPH PART 21 REPORT INVOLVING POTENTIAL FAILURE OF CERTAIN ROSEMOUNT PRESSURE TRANSMITTERS The following information was received via fax:

"Re: Notification under 10 CFR Part 21 for certain Model 3051N Pressure transmitters "Pursuant to 10 CFR Part 21, section 21.21(b) Rosemount Nuclear Instruments, Inc. (RNII) is writing to inform you that a limited number of Model 3051 N pressure transmitters listed in the attachment may exhibit erratic, unstable output prior to an off-scale failure. The affected transmitters were shipped from RNII between March 31, 2002 and November 20, 2002.

"1.0 Name and address of the individual providing the information:

"Mr. Marc D. Bumgarner Vice President & General Manager Rosemount Nuclear Instruments, Inc.

8200 Market Boulevard Chanhassen, MN 55317 "2.0 Identification of-items supplied:

"Certain Model 3051N pressure transmitters identified in the attachment.

"3.0 Identification of the firm supplying the item:

03/20/2008 U.S. Nuclear Regulatory Commission Operations Center Event Report Page 2 General Information or Other (PAR)

Event#

44082 "Rosemount Nuclear Instruments, Inc.

8200 Market Boulevard Chanhassen, MN 55317

."4.0 Nature of the failure and potential safety hazard:

"The Model 3051N Smart Pressure Transmitter is dedicated for nuclear use consistent with the requirements of 10 CFR Part 21. It.is qualified for use in safety related applications per IEEE 323-1983 (mild environment) and IEEE 344-.1987 for seismic applications as documented in its associated qualification reports.

"The Model 3051 N pressure transmitter contains an application-specific integrated circuit (ASIC) which performs' the Digital to Analog Conversion (DAC). Procurement and production records indicate that a limited number of Model 3051 N pressure transmitters manufactured between January 2002 and October 2002 have DAC ASICs which may contain phosphorus as the encapsulation material.

"ASIC industry experts have since determined that under certain conditions the phosphorus compound can lead to reduced insulation resistance of the integrated circuit,.with potentially adverse impact on performance. As a result, ASIC and IC manufacturers eliminated the use of phosphorus in their products. Industry experts have examined the performance of phosphorus materials in electronic circuits under various conditions and estimated a potential ASIC failure rate of approximately 1% for the general population of phosphorus-containing electronic circuits.

"Three Model 3051 N transmitters have recently been returned to RNII due to erratic, unstable,-or off-scale output.

Failure analysis identified the phosphorus-containing encapsulation material of the DAC ASIC as the cause of failure for these transmitters. These transmitters were installed and performing properly for 3-5 years before failure.

"Failure of the DAC ASIC depends on several factors, including:

"Phosphorus concentration "Spacing of ASIC leads "Voltage driving the ASIC (which affects operating temperature)

"Ambient temperature "The observed failure rate of the DAC ASIC in Model 3051 N pressure transmitters indicates a potential reliability concern. As a result, notification is being made in accordance with 10 CFR Part 21 to customers that purchased a transmitter from the potentially affected population. A transmitter with a failing DAC ASIC will annunciate itself by erratic or unstable output, followed by off-scale output (high or low).

"5.0 The corrective action which is taken, the name of the individual or organization responsible for that action, and the length of time taken to complete that action:

"The use of phosphorus in the DAC ASIC was eliminated in October 2002.

"Model 3051 N pressure transmitters affected by this notification may be returned to RNII for replacement at no charge.

"6.0 Any advice related to the potential failure of the item:

"The end user is advised to determine the impact of this potential reliability issue upon its plant's operation and safety, and take action as deemed necessary. Affected transmitters may be returned to RNII for replacement at no charge.

"Rosemount Nuclear Instruments, Inc. is committed to the nuclear industry and: remains dedicated to the supply of

03/20/2008 U.S. Nuclear Regulatory Commission Operations Center Event Report PaL'e 3 General Information or Other (PAR)

Event #

44082 high quality products to our customers. If you have any questions, or require additional information related to this issue, please contact: Mike Dougherty (205) 865-1112, Gerard Hanson (952) 949-5233, Bob Cleveland (952) 949-5206, or Matt Doyle (952) 949-5204."

Facilities affected which were identified in the referenced attachments: Cook Nuclear Plant, Vermont Yankee, Quad Cities Nuclear Station, and Robinson.

Mar-20-2008 11:32 AM EPM OUT ROSEMOUNT NUCLEAR 9529495201 1/7 EMERSON-Process Management ROSEMOUNT' Nuclear Facsimile RdSehm)unt Nuclear Instruments, Inc.

8200 Market Boulevard Chanhassen, MN 55317 Telephone 1 (952) 949-52U4 Fax 1 (952) 949-5201 David.Robet@s@Enmirsor.cotn To:

Company:

FAx Number:

Date:

From:

No. of Pages:

NRC Operations Center (301) 816-5151 3/20/08 David Roberts, Quality Manager 7, Including cover paga Rosernount Nuolear Instruments is submitting the attached notification as required by 10 CFR Part

21. Please contact me if you have any questions.

Sincerely, David T. Roberts Quality Manager Rosemount Nuclear Instruments, Inc,

-Mar-20-2008 11:32 AM EPM OUT ROSEMOUNT NUCLEAR 9529495201 2/7 DfltE~fii llRosemountl Ntaole-r instruments, Inc.

ROSEMOWIUNT 8200 Market Boulevard Nuclear Chanhassen, MN 5531? USA Tel 1 (952) 949-5210 Fax 1 (952) 949-5201 20 March 2008 www.RosmnurtNUcissr com U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Attn: Oocument Control Desk Re: Notification under 10 CFR PArt 21 for certain Model 3051N Pressure ltanimitters Pursuant to 10 CFR Part 2-1, section 21-.21(b), Rosemount Nuclear instruments, Inc. (RNII) is writing to inform you that a limited numfber of Model ?051 N pressure transmitters listed in the attachment may exhibit erratic, unstable output prior to an off-scale failure. The affected transmitters were shipped from RNII between March 31, 2002 and November 20, 2002.

1.0 Name and address of the ihdividual providing the information:

Mr. Marc D. Burtgarner Vice President & General Manager Rosemount Nuclear Instrumenrts, Inc.

8200 Market Boulevard Chanhassen, MN 55317 2.0 Identification of items supplied:

Certain Model 3051N pressure transmitters identified in the attachment.

3.0 Identification of firm supplying the item:

Rosemount Nuclear Instruments, Inc.

8200 Market Boulevard Chanhassen, MN 55317 4.0 Nature of the failure and potential safety ha2ard:

The Model 3051 N Smart Pressure Transmfitter is dedicated for nuclear use consistent with the requirements of 10 CFR Part 21. It is qualified for use ih safety related applications per 12EEE 323-1983 (Mild environment) and [I 344-1987 for geismic applications as documented in its associated qualification reports.

The Model 3051 N pressure transmitter contains an application=specific integrated circuit (ASIC), which performs the Digital to Analog Conversion (DAC). Procurement and production records indicate that a limited number of Model 3051 N pressure transmitters manufactured between January 2002 and October 2002 have DAC ASI:s which may contain phosphorus as the encapsulation material.

ASIC industry,experts have since determined that under certain conditions the phosphorus compound can lead to reduced insulation resistance of the integrated circuit, with potentially adverse impact on performahce. As a result, ASIC and IC manufacturers eliminated the use of phosphorus in their products. Industry experts have examined the performance of phgsphrus.'materials in. electronic circuits under various conditions and Page 1 of 2

-Mar-20-2008 11:33 AM EPM OUT ROSEMOUNT NUCLEAR 9529495201

.3/7 estimated a potential ASIC failure rtte of approxirnately1% for the general population of phosphorus-c.ontaining electronic circuits.

Three Model 3051N transmitters have recently been returned to RNI[ diue tp erratic, unstable, or off-scale output. Failure analysis identified the phosphorus-contraining encap~sulation material of the 1AC ASIC as the cause of failure for these transmitters.

These transmitters were installed and performing properly for 3-5 years before failure.

Failure of the DAC ASIC depends on several factors, iholuding:

Voltage driving the ASIC (which affects operating temperature)

  • Ambient temperature The observed failure rate of the DAG ASIC in Model 3051 N press.ure transmitters indicates a potential reliability concern. As a result, notification is being made in accordance with 10 CFR Part 21 to customers that purc~hased a transmitter from the potentially affected populatiofl. A transmitter with a failing DAC ASIC will annunciate itself by erratiC or unstable output, followed by off-scale output (high or low).

S.0 The corrective action which is taken, the name of the individual or organization responsible for that action, and the length of time taken to complete that action:

  • The use of phosphorus in the.DAC ASIC was eliminated in October 2002.

Model 3051 N pressure transmitters affected by this notification may be returned to RNII for replacement at no charge.

6.0 Ahy advice related to the potential failure of the item:

The end user is advised to detetfrmfil the impact of this potential reliability issue upon its plant's operation and safety, and take action as deemed necessary. Affboted transmitters may be returned to RNII for replacement at no charge-Rosemount Nuclear Instrunients, Iho. is committed to the nuclear industry and remains dedicated to the supply of high quality products to our customers. If you have any questions, or require additional information related to this issue, please contact: Mike Dougherty (208) 885-1112, Gerard Hanson (952) 949=5233, Bob Cleveland (952) 949-5206, or Matt Doyle (952) 949=5204.

Sincerely, Marc.. ?umgarner Vice President & General Manager Rosemount Nuclear Instruments, Inc.

ROSEMOUNT' Nuclear Page 2 of 2

  • Mar-20-2008 11:33 AM EPM OUT ROSEMOUNT NUCLEAR 9529495201 4/7 ATTACHMENT: 10 CFR Part 21 Notification - 20 March 2008.

American Electric Power Co [nc Sales

  • Ship Sales Oftder Purchase Order Model Number S/N Ship Date Site I.

. F:-ý =

.i 1023104 190-0000028023 3Q51NG4A02AtJH_.2M6 1201385 5/14/2002 COOKNUCLEAR PLANT 1023104 190-000002M3 3051NG4A02A1JH2B2M6 1201386 514/2002 COOK NUCLEAR PLANT 1023104 190-0000023023 3051NG4A02A1JH2B2M6 1201386 511412Q_2 COOK NUCLEAR PLANT 1023104 190-0000023023 3.51NG.4AO2A1JH2B2Ma 1201387 5114/2002 COOK NUCLEAR PLANT 1023104 190-0000023023 3O5ING4AO2AIJH2B2M6 1201388 511412002 COOK NUCLEAR PLANT 1023104 190-0000023023 3051NG4A02A1JH2B2M6 1201389 5/14/2002 COOK NUCLEAR PLANT 1023104 190-0000023023 3051NG4AO2AIJN2B2M6 1201390 Sf1412002 COOK NUCLEAR PLANT 10231 04 190Q00Q002302305NGA21HBM 1201391 511 4/2002 COOK NUCLEAR PLANT 1023104 190-0000023023

?05ING4A02A1JH2B2M6 1201392 5/14/2002 COOK NUCLEAR PLANT 1023104 190-0000023023 3051NG4A02A1JH2B2M6 1201393 5/1412.62 COOK NUCLEAR PLANT 1023104 190-0000023023 3051NNQ4A02A1JH2B2M6 1201394 5/14/2002 COOK NUCLEAR PLANT ROSEMOUNT" Nuclear

Mar-20-2008 11:33 AM EPM OUT ROSEMOUNT NUCLEAR 9529495201 5/7 ATTACHMENT: 10 CFR Part 21 Notification - 20 March 2008.

Entergy, Corp sales Oe'der Purchase Order Model Nuffiber SIN Ship Date Site 1061163 VY01 4098 --.

3051 ND2AQ.2A1AH28S 1243741 8/12/2002 VERMONT YANK.EE 1061163 VY014098 30S1ND2A02A1AH2BS 1243742 8/1212002 VERMONT YANKEE 1061't63 VY014098 3061N.2A02A1AH2BS 1243743 8/12/2002 VERMONT YANKEE 1083248 VY014098 30SINOAO2B1AN2.BS 1260592 9I1.8/202. VRMONTYANKEE--

1083248 VY014098 0.51ND2A2B1AH2BS 126093 9/18/2002 VERMONT YANKEE 1083248 VY0140.8 3051ND2A02D1AH2BS 1260594 9/18/2002 VERMONTYANKEE 1084239 VY014552 3051 ND3AO.2BIAH2_ B8 1263278 9/20 1084239 WOl 4552

/2002

/2002 VERMONT YANKEE 1084239 VY014552 3061 ND3A02B1AH2BS 1263277 9120 VERMONT YANKEE ROSEMOUNT*

Nuclear

.Mar-20-2008 11:33 AM EPM OUT ROSEMOUNT NUCLEAR 9529495201 6/7 ATTACHMENT-10-CFR Part 21 Notification =20 Marph 2008.

Exelon Generation Co LLC Order Purchase Order Model Number SIN 1042078 00044796 REV 001 3051NG5AO2AIJH2B2 1224700 Ship Site Date Y/25/2002 'QAD CITIES NUCLEAR STATION ROSEMOUNT"

, Nuclear

Mar-20-2008 11:33 AM EPM OUT ROSEMOUNT NUCLEAR 9529495201 7/7 ATTACHMENT: 10 CFR Part 21 Notificatian = 20 Marth 2008.

Progress.Energy Carolinas Inc Sates Order Purchase Order Model Number SIN Ship Date Site 1026235 00066666 3051 NG5A02AIAH2PM 1225473 6129/2002 ROBINSON 1026235 00066666 3051NG5AO2A1AH2PM 1225474 6/29/2002 ROBINSON 1026235 00066666 3051NGA02.A1AH2PM 122547*

6/29/2002 ROBINSON 1026235 00066666 3O51NG5A02AIAH2PM 1225476-6/29/2002 ROBINSON 1026235 00066666 3051 NGSA02A1AH2PM 1225477

$/29/2002 ROBINSON 1026235:

00066666 SC51NGSA0ZA1AH2PM 1225478 6$2912002 ROBINSON 1026235 00066686 3051NG,5A02A1AH2P-M 1225479 6/29/2-002 ROBINSON 1026235 00066$66 351NG5A0_2A1AH2PM 1225480 8/29/2002 ROBINSON 1026235 00066666 3051 NG5A02A1AH2FM 1225481 6129/2002 ROBINSON 1028235 00066066 3O51NG5AQ2A1AH2PM 1225482 6/29/2002 ROBINSON 1026235 00066666 3051 NGM02IAH2PM 1225485 6/29/2002 ROBINSON 1099448 00096874 3D51NG5AO2A1AH2PM 1278382 11/2012002 ROBINSON ROSEMiOUNT" Nuclear