FENOC Perry Nuclear Power Station
- 10 Center Road FirstEnergy Nuclear Operating Company Perry, Ohio 44081 Barry S. Allen 440-280-5382 Vice President Fax: 440-280-8029 Marchl 11,'2008 PY-CEI/OEPA-0483L Ohio Environmental Protection Agency Division ofWater.(PolilUtlion Control EnforCement Section, ES/DMR P.O.,-Box 1049 Columbus, Ohio 43216-1049
SUBJECT:
Perry Nuclear Power Plant, February NPDES Discharge Monitoring Report Enclosed are the Perry Nuclear Power Plant, NPDES monthly report forms for the month of February 2008. No violations occurred during this period.
If you have questions or require additional information, please contact Mrs. Liz Ryan at (440) 280-5536.
Sincerely, Enclosures,.,
A-Station Code o004Report-BStation Code, 094 Report C Station Code 601 Report D Station Code "602 Report-E Station Code 800 Report cc: NRC Region IlI NRC Resident Inspector NRR Project Manager NRC Document Control Desk (Docket No. 50-440)
Page 1 of8 Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:
LOCATION:
COUNTY:
DISTRICT:
FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:
STATION CODE:
MONITORING PERIOD:
REPORTING LAB:
ANALYST:
NO DISCHARGE INDICATOR:
3IB00016*ID 004 2008-02-01 To: 2008-02-29 CCB125 -
Liz Ryan Water Zinc, Total Copper, Total Oxidants, Total Chlorine, Total PARAMETER Temperature Flow Rate pH Recoverable Recoverable Residual Residual PARAMETER CODE 00011 50050 00400 01094 01119 34044 50060 UNITS 4103 4108 6653 4107 4107 4106 4106 FREQUENCY I/Day
]/Day 2/Week I/Month I/Month When Disch.
When Disch.
SAMPLING TYPE Continuous Continuous Grab Grab Grab Grab Grab 2008-02-01 45 69.4 8.57 AH AA 0.05 2008-02-02 44 60.5 AH AA 0.05 2008-02-03 43 64.8 AH AA 0.05 2008-02-04 43 66.2 AA 8.0 6
AH AA 0.05 2008-02-05 45 72.2 8.68 AH AA 0.05 2008-02-06 44 76.4 AH AA 0.05 2008-02-07 46 85.3 AH AA 0.05 2008-02-08 45 83.0 8.65 AH AA 0.05 2008-02-09 46 86.4 AH AA 0.05 2008-02-10 47 90.9 AH AA 0.05 2008-02-11 44 98.9 AH AA 0.05 2008-02-12 43 85.5 8.5 AH AA 0.05 2008-02-13 45 91.4 AH AA 0.05 2008-02-14 52 91.7 AH AA 0.05 2008-02-15 47 71.7 8.63 AH AA 0.05 2008-02-16 44 92.7 AH AA 0.05 2008-02-17 47 88.1 AH AA 0.05 2008-02-18 49 90.5 AH AA 0.05 2008-02-19 45 102.3 8.42 AH AA 0.05 2008-02-20 43 104.0 AH AA 0.05 2008-02-21 43 103.3
'AH AA 0.05 2008-02-22 43 100.3 8.54 AH AA 0.05 2008-02-23 43 95.5 AH AA 0.05 2008-02-24 43 90.3 AH AA 0.05 2008-02-25 44 76.1 AH AA 0.05 2008-02-26 43 79.2 8.44 AH AA 0.05 2008-02-27 43 841 AH AA 0.05 2008-02-28 42 102.1 AH AA 0.05
- 2008-02-29 43 100.5 8.52 AH AA 0.05 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MM/DDIYY)
Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative significant penalties for submitting false information, including the possibility of
/g,[j/
VP, opeeda fine and imprisonment.
EDMI
?-
When completed mail this report to: EDMR Administrator, EDMR Administrator,... OH, Page I https ://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt. do?actType=viewWithXslt&f...
3/4/2008
Page 2 ot 8 Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:
LOCATION:
COUNTY:
DISTRICT:
FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:
STATION CODE:
MONITORING PERIOD:
REPORTING LAB:
ANALYST:
NO DISCHARGE INDICATOR:
3IB00016*ID 004 2008-02-01 To: 2008-02-29 CCB125 Liz Ryan PARAMETER Chlorination/Brominatior Duration PARAMETER 78739 CODE UNITS 6655 FREQUENCY When Disch.
SAMPLING TYPE Total 2008-02-01 100 2008-02-02 100 2008-02-03 100 2008-02-04 100 2008-02-05 100 2008-02-06 100 2008-02-07 100 2008-02-08 100 2008-02-09 100 2008-02-10 100 2008-02-11 100 2008-02-12 100 2008-02-13 100 2008-02-14 100 2008-02-15 100 2008-02-16 100 2008-02-17 100 2008-02-18 50 2008-02-19 100 2008-02-20 100
-2008-02-21 100 2008-02-22 100 2008-02-23 100 2008-02-24 100 2008-02-25 100 2008-02-26 100 2008-02-27 100 2008-02-28 100 2008-02-29 55 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MMIDDIYY)
Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative significant penalties for submitting false information, including the possibility of VPR fNhk.deOY fine and imprisonment.
(-0 When completed mail this report to: EDMR Administrator, EDMR Administrator.,. OH, Page 2 https://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXslt&f...
3/4/2008
Page 3 ot8 Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:
LOCATION:
COUNTY:
DISTRICT:
FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:
3IB00016*ID STATION CODE:
094 MONITORING PERIOD:
2008-02-01 To: 2008-02-29 REPORTING LAB:
ANALYST:
NO DISCHARGE INDICATOR:
AL Water Zinc, Total Copper, Total Oxidants, Total Chlorine, Total Temperature Recoverable Recoverable Residual Residual PARAMETER CODE 00011 50050 00400 01094 01119 34044 50060 UNITS 4103 4108 6653
.4107 4107 4106 4106 FREQUENCY 1/Day 1/Day 2/Week I/Month I/Month When Disch.
When Disch.
SAMPLING TYPE Continuous Continuous Grab Grab Grab Grab Grab 2008-02-01 2008-02-02 2008-02-03 2008-02-04 2008-02-05 2008-02-06 2008-02-07 2008-02-08 2008-02-09 2008-02-10 2008-02-11 2008-02-12 2008-02-13 2008-02-14 2008-02-15 2008-02-16 2008-02-17 2008-02-18 2008-02-19 2008-02-20 2008-02-21 2008 22 2008-2-23 2008-02-24 2008-02-25 2008-02-26 2008-02-27 2008-02-28 2008-02-29 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MM/DD/YY)
Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative AD1 *k
- finsignificant penalties for submitting false information, including the possibility ofai s
n'j-n opleteda t
fine and imprisonment.
I When completed mail this report to: EDMR Administrator, EDMR Administrator,,, OH, Page 3 https://ebiz.epa.ohio.gov/edwr.web/page/reportlviewWithXslt.do?actType-viewWithXslt&f...
3/4/2008
Page 4 ot 8 Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:
LOCATION:
COUNTY:
DISTRICT:
FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:
3IB00016*ID STATION CODE:
094 MONITORING PERIOD:
2008-02-01 To: 2008-02-29 REPORTING LAB:
ANALYST:
NO DISCHARGE INDICATOR:
AL PARAMETER Chlorination/Bromination Duration PARAMETER 78739 CODE UNITS 6655 FREQUENCY When Disch.
SAMPLING TYPE Total 2008-02-01 2008-02-02 2008-02-03 2008-02-04 2008-02-05 2008-02-06 2008-02-07 2008-02-08 2008-02-09 2008-02-10 2008-02-11 2008-02-12 2008-02-13 2008-02-14 2008-02-15 2008-02-16 2008-02-17 2008-02-18 2008-02-19 2008-02-20 2008-02-21 2008-02-22 2008-02-23 2008-02-24 2008-02-25 2008-02-26 2008-02-27 2008-02-28 2008-02-29 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MM/DDIYY)
Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative VP1 ) ti CC/-
significant penalties for submitting false information, including the possibility of When completed mail this report to: EDMR Administrator, EDMR Administrator,,, OH, Page 4 https ://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXslt&f...
3/4/2008
.rage D oi 6 Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:
LOCATION:
COUNTY:
DISTRICT:
FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:
3IB00016*ID STATION CODE:
601 MONITORING PERIOD:
2008-02-01 To: 2008-02-29 REPORTING LAB:
ANALYST:
NO DISCHARGE INDICATOR:
AL PARAMETER Flow Rate pH Total Suspended Oil and Grease, PARAMETER Flow Rate pHSolids Total PARAMETER CODE 50050 00400 00530 00550 UNITS 4108 6653 4106
-4106 FREQUENCY Continuous 1 / 2 Weeks 1 / 2 Weeks 1 / 2 Weeks SAMPLING TYPE 24hr Total Grab Grab Grab 2008-02-01 2008-02-02 2008-02-03 2008-02-04 2008-02-05 2008-02-06 2008-02-07 2008-02-08 2008-02-09 2008-02-10 2008-02-11 2008-02-12 2008-02-13 2008-02-14 2008-02-15
- 2008-02-16 2008-02-17 2008-02-18 2008-02-19 2008-02-20 2008-02-21 2008-02-22 2008-02-23 2008-02-24 2008-02-25 2008-02-26' 2008-02-27 2008-02-28 2008-02-29 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MM/DD/YY)
Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative significant penalties for submitting false information, including the possibility of ai sm-0 When co e
i fine and imprnsonmentrator, Er,-
3-O When completed mail this report to: EDMR Administrator, EDMR Administrator,... OH, Page 5 httpsH//ebiz.epa.ohio.gov/edwr.web/page/report'viewWithXslt.do?actType=viewWithXslt&f...
3/4/2008
,'age o ot zs Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:
LOCATION:
COUNTY:
DISTRICT:
FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:
3IB00016*ID STATION CODE:
602 MONITORING PERIOD:
2008-02-01 To: 2008-02-29 REPORTING LAB:
ANALYST:
NO DISCHARGE INDICATOR:
AL PARAMETER Flow Rate pH Total Suspended Oil and Grease, Iron, Total Copper, Total
_ _Solids.
Total Recoverable Recoverable PARAMETER CODE 50050 00400 00530 00550 00980 01119 UNITS 4108 6653 4106 4106 4107 4107 FREQUENCY Continuous 1/ 2 Weeks 1 / 2 Weeks 1 /2 Weeks 1 / 2 Weeks 1 / 2 Weeks SAMPLING TYPE 24hr Total Grab 24hr Composite Grab 24hr Composite 24hr Composite 2008-02-01 2008-02-02 2008-02-03 2008-02-04 2008-02-05 2008-02-06 2008-02-07 2008-02-08 2008-02-09 2008-02-10 2008-02-11 2008-02-12 2008-02-13.
2008-02-14 2008-02-15 2008-02-16 2008-02-17 2008-02-18 2008-02-19 2008-02-20 2008-02-21 2008-02-22 2008-02-23 2008-02-24 2008-02-25 2008-02-26 2008-02-27 2008-02-28 2008-02-29 Name/ritle of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MMIDD/YY)
Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative significant penalties for submitting false information, including the possibility ofenmt" When Co e al t fine and imprisonment. rato, 3-A,6 When completed mail this report to: EDMR Administrator, EDMR Administrator,_ OH, Page 6 https://ebiz.epa.ohio.gov/edwr.web/page/reportlviewWithXslt.do? actType=viewWithXslt&f...
3/4/2008
rage ui o Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:
LOCATION:
COUNTY:
DISTRICT:
FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:
STATION CODE:
MONITORING PERIOD:
REPORTING LAB:
ANALYST:
NO DISCHARGE INDICATOR:
3IB00016*ID 800 2008-02-01 To: 2008-02-29 CCB 125 Liz Ryan PARAMETER Water Zinc, Total Copper, Total Temperature Recoverable Recoverable PARAMETER CODE 00011 01094 01119 UNITS 4103 4107 4107 FREQUENCY 1/Day 1/Month I/Month SAMPLING TYPE Continuous Grab Grab 2008-02-01 32 2008-02-02 32 2008-02-03 32 2008-02-04 32 AA 8.0 3
2008-02-05 32 2008-02-06 34 2008-02-07 34 2008-02-08 34 2008-02-09 34 2008-02-10 35 2008-02-11 33 2008-02-12 33 2008-02-13 32 2008-02-14 44 2008-02-15 31 2008-02-16 32 2008-02-17 33 2008-02-18 33 2008-02-19 33 2008-02-20 32 2008-02-21 32 2008-02-22 32 2008-02-23 32 2008-02-24 32 2008-02-25 32 2008-02-26 32 2008-02-27 32 2008-02-28 32 2008-02-29 33 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MM/DD/YY)
Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative AP, * {]d*
significant penalties for submitting false information, including the possibility ofneni smn.
I WVe p
et at fine and imprisonment.
EDM-Amnto
,, OH
?- 7 o
When completed mail this report to: EDMR Administrator, EDMR Administrator,.
01-OH Page 7 https://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXs1t&f...
3/4/2008
rage 6 o0 6 Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:
LOCATION:
FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 PERMIT NUMBER:
3IB00016*ID MONITORING PERIOD:
2008-02-01 To: 2008-02-29 PARAMETER COMMENTS:
Station Code Parameter Name Parameter Code Date Unit Comment 004 Oxidants, Total Residual 34044 2008-02-01 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-02 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-03 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-04 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-05 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-06 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-07 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-08 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-09 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-10 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-11 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-12 4106 No bromrination event this date 004 Oxidants, Total Residual 34044 2008-02-13 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-14 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-15 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-16 4106.
No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-17 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-18 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-19 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-20 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-21 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-22 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-23 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-24 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-25 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-26 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-27 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-28 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-02-29 4106 No bromination event this date httpsl//ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXslt&f...
3/4/2008