April 3, 2008 Mr. Terry J. Garrett Vice President, Engineering Wolf Creek Nuclear Operating Corporation 1550 Oxen Lane, NE Burlington, KS 66839
SUBJECT:
AUDIT
SUMMARY
REGARDING THE WOLF CREEK GENERATING STATION, UNIT 1, LICENSE RENEWAL APPLICATION
Dear Mr. Garrett:
By letter dated September 27, 2006, Wolf Creek Nuclear Operating Corporation submitted an application pursuant to 10 CFR Part 54, to renew the operating license for Wolf Creek Generating Station for review by the U.S. Nuclear Regulatory Commission (NRC or the staff).
During the weeks of March 26, 2007 through July 11, 2007, the staff led project teams responsible for auditing and reviewing selected aging management programs, aging management reviews, and time-limited aging analysis described in the license renewal application. A summary of the audit and review results is accessible from the Agencywide Documents Access and Management System (ADAMS) under Accession Number ML073340491.
If you have any questions, please contact me at 301-415-3617 or by e-mail at TXT1@nrc.gov.
Sincerely,
\\RA\\
Tam Tran, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-482 cc: See next page
ML080790336 OFFICE LA:DLR PM:RLR:DLR BC:RLR:DLR NAME IKing T. Tran L. Lund DATE 3/19/08 3/19/08 4/3/08 Letter to T. Garrett from T. Tran, dated April 3, 2008 DISTRIBUTION:
SUBJECT:
AUDIT
SUMMARY
REGARDING THE WOLF CREEK GENERATING STATION, UNIT 1, LICENSE RENEWAL APPLICATION HARD COPY:
DLR RF E-MAIL:
PUBLIC SSmith (srs3)
SDuraiswamy RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDci RidsNrrDra RidsNrrDe RidsNrrDeEemb RidsNrrDeEeeb RidsNrrDss RidsOgcMailCenter RidsNrrAdes JDonohew GPick, RIV SCochrum, RIV CLong, RIV SRay VGoel
Wolf Creek Generating Station cc:
Jay Silberg, Esq.
Pillsbury Winthrop Shaw Pittman, LLP 2300 N Street, NW Washington, DC 20037 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-7005 Senior Resident Inspector U.S. Nuclear Regulatory Commission PO Box 311 Burlington, KS 66839 Chief Engineer, Utilities Division Kansas Corporation Commission 1500 SW Arrowhead Road Topeka, KS 66604-4027 Office of the Governor State of Kansas Topeka, KS 66612 Attorney General 120 SW 10th Avenue, 2nd Floor Topeka, KS 66612-1597 County Clerk Coffey County Courthouse 110 South 6th Street Burlington, KS 66839 Thomas A. Conley, Section Chief Radiation and Asbestos Control Kansas Department of Health and Environment Bureau of Air and Radiation 1000 SW Jackson, Suite 310 Topeka, KS 66612-1366 Vice President Operations/Plant Manager Wolf Creek Nuclear Operating Corporation PO Box 411 Burlington, KS 66839 Supervisor Licensing Wolf Creek Nuclear Operating Corporation PO Box 411 Burlington, KS 66839 U.S. Nuclear Regulatory Commission Resident Inspectors Office/Callaway Plant 8201 NRC Road Steedman, MO 65077-1032 Kevin J. Moles, Manager Regulatory Affairs Wolf Creek Nuclear Operating Corporation PO Box 411 Burlington, KS 66839 Lorrie I. Bell, Project Manager Wolf Creek Nuclear Operating Corporation PO Box 411 Burlington, KS 66839 Mr. Gordon A. Clefton Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708