E-mail Dated 02/27/08 RAIs for Relief Request VRR-GGNS-2007-2 to Mike Larson at Entergy Dated 02/27/08 from Lynnea Wilkins
ML080600009
Person / Time
Site: Grand Gulf 
Issue date: 02/27/2008
From: Lynnea Wilkins
NRC/NRR/ADRO/DORL/LPLIV
To: Larson M
Entergy Operations
Wilkins, L E, NRR/DORL/LPL4, 415-1377
References
TAC MD7758, VRR-GGNS-2007-02
Download: ML080600009 (2)


Text

From:

Lynnea Wilkins To:

MLARSON@entergy.com Date:

2/27/2008 4:04:45 PM

Subject:

DRAFT RAI for MD 7758 - Grand Gulf SRV relief reqest

Mike, The draft RAIs for Relief Request VRR-GGNS-2007-2 (MD7757) are provided below.

Please let me know your convenient times and dates in the next week to schedule a conference call to ensure that the questions are clearly understood and to obtain the date of the responses to the RAIs.

Thanks Relief Request VRR-GGNS-2007-2, MD7757

1. Verify [acknowledge that it is true] that Valves 1B21-F041K, 1B21-F041F, 1B21-F051F, 1B21-F051B, 1B21-F041D, 1B21-F047D were refurbished to a like-new condition prior to being placed in storage and later installed in October 2005. Verify that Valves 1B21-F047L, 1B21-F041G, 1B21-F047G, 1B21-F051C and 1B21-F047C were refurbished to a like-new condition prior to being placed in storage and later installed in March 2007.
2. Discuss if the controlled environment for the storage of Valves 1B21-F041K, 1B21-F041F, 1B21-F051F, 1B21-F051B, 1B21-F041D, 1B21-F047D, 1B21-F047L, 1B21-F041G, 1B21-F047G, 1B21-F051C and 1B21-F047C was equipped to prevent condensation and corrosion.
3. Please provide test results for Dikkers Model G-471 safety relief valves (SRVs) that were maintained in a controlled environment similar to the GGNS controlled environment for an extended period of time and setpoint tested prior to actual installation. As an alternative, discuss why the as-found set-pressure test results for Dikkers Model G-471 SRVs provided in a letter dated September 28, 2007 (Agencywide Documents Access and Management System Accession No. ML072740030) are be applicable to the GGNS SRVs.

Lynnea Wilkins General Engineer, NSPDP NRR/DORL/LPL4 301-415-1377 CC:

Bhalchandra Vaidya

Mail Envelope Properties (47C5D06D.261 : 11 : 10422)

Subject:

DRAFT RAI for MD 7758 - Grand Gulf SRV relief reqest Creation Date 2/27/2008 4:04:45 PM From:

Lynnea Wilkins Created By:

LEW2@nrc.gov Recipients entergy.com MLARSON (MLARSON@entergy.com) nrc.gov TWGWPO04.HQGWDO01 BKV CC (Bhalchandra Vaidya)

Post Office Route entergy.com TWGWPO04.HQGWDO01 nrc.gov Files Size Date & Time MESSAGE 2631 2/27/2008 4:04:46 PM TEXT.htm 1996 Options Expiration Date:

None Priority:

Standard ReplyRequested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard