Appendix B Planar-feature Orientations Measured from Acoustic Televiewer Logs

Fracture Orientations Interpreted from MW-46 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw46i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 6.64 9.9 55.3 less-open 6.87 21.3 57.9 open Note that down-dip compass azimuth 7.17 17.0 61.5 less-open is perpendicular to the strike direction.

7.51 9.6 41.9 less-open 7.73 23.9 42.9 less-open Note that interpreted down-dip compass 8.12 14.7 47.1 less-open azimuths are with respect to 8.32 11.2 55.7 less-open magnetic north.

8.65 132.2 72.6 less-open 8.69 353.6 61.3 less-open Down-dip azimuths & dip angles were 8.91 358.9 54.9 less-open corrected for borehole deviation from 9.06 355.1 54.1 less-open vertical.

9.18 348.1 53.9 less-open 9.27 349.0 53.4 less-open 9.63 25.9 51.0 less-open 9.82 30.5 61.4 less-open 10.09 42.2 57.5 less-open 10.27 67.8 40.7 open 10.47 355.3 45.8 less-open 10.82 337.3 61.9 less-open 11.22 8.3 55.8 less-open 11.98 74.7 58.5 less-open 12.14 135.6 43.2 less-open 12.57 129.1 62.8 less-open 13.15 137.7 63.2 less-open 14.10 359.5 49.3 less-open 14.44 358.5 51.0 less-open 14.82 127.3 75.7 less-open 15.66 354.4 41.6 less-open 15.96 135.3 47.7 less-open 17.01 161.6 63.1 less-open 17.34 174.9 54.7 less-open 17.57 120.1 58.0 less-open 17.61 9.6 41.2 less-open 18.68 0.8 54.3 less-open 19.10 356.9 66.4 less-open 19.34 176.8 55.4 less-open 19.51 174.19 57.57 less-open 20.27 159.25 51.82 less-open 20.70 172.5 60.4 less-open 21.62 343.2 70.2 less-open 22.65 307.8 74.2 less-open 23.66 288.6 62.1 less-open 25.74 339.5 75.2 less-open 26.59 317.3 71.9 less-open Page",1 'of 2

Fracture Orientations Interpreted from MW-46 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw46i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 26.87 170.5 58.6 less-open 27.80 325.8 68.9 less-open 29.58 154.7 89.9 less-open 29.83 182.1 89.5 less-open 30.10 160.7 89.5 less-open

(.

Page:2 of 2

Fracture Orientations Interpreted from MW-53 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw53i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 59.49 212.0 35.9 less-open 59.87 91.4 66.4 less-open Note that down-dip compass azimuth 60.26 9.2 22.5 less-open is perpendicular to the strike direction.

61.46 186.0 21.4 less-open 61.52 239.1 80.2 less-open Note that interpreted down-dip compass 62.51 246.1 76.4 less-open azimuths are with respect to 63.02 234.1 16.3 less-open magnetic north.

63.35 243.8 76.1 less-open 63.96 248.8 80.1 less-open Down-dip azimuths & dip angles were 64.71 249.7 81.5 less-open corrected for borehole deviation from 64.93 210.7 23.7 less-open vertical.

65.30 200.0 20.3 less-open 66.26 110.1 55.4 less-open 66.92 208.2 30.9 less-open 66.93 243.4 73.6 less-open 67.07 49.5 58.9 less-open 67.58 339.7 16.7 less-open 68.22 244.1 78.7 less-open 68.89 101.2 50.7 less-open 69.39 298.0 17.5 less-open 70.71 81.8 43.0 less-open 72.16 225.0 45.6 less-open 72.43 72.0 46.6 less-open 72.64 60.7 44.5 less-open 72.87 81.0 37.1 less-open 72.97 304.5 65.7 less-open 73.11 81.7 46.4 less-open 73.29 267.3 10.4 less-open 73.32 113.4 37.6 less-open 73.64 331.3 32.8 less-open 73.84 83.1 63.7 less-open 73.94 88.7 64.5 less-open 74.26 93.2 52.8 less-open 74.36 96.8 53.6 less-open 74.47 84.6 56.2 less-open 74.69 73.1 50.8 less-open 75.09 94.2 56.8 less-open 75.44 9.4.9 57.8 less-open 75.55 86.8 52.7 less-open 75.73 127.6 57.6 less-open 76.20 90.8 59.6 less-open 76.35 84.4 35.3 less-open 76.39 80.7 43.6 less-open 76.80 79.2 43.2 less-open Page 1'"of 3

Fracture Orientations Interpreted from MW-53 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw53i.xls depth (feet) 77.26 77.98 78.86 79.55 79.68 79.73 83.82 83.96 85.22 85.75 87.78 87.98 90.57 90.66 91.50 91.51 92.29 92.76 93.80 94.12 94.51 95.00 95.28 95.92 96.21 96.82 98.29 100.16 100.81 101.34 101.65 103.35 103.37 103.62 103.96 104.57 104.65 104.85 105.48 105.75 106.77 106.85 108.23 109.11 down-dip compass azimuth (degrees) 97.1 97.1 91.5 81.3 249.3 67.2 283.3 227.8 175.8 181.8 173.7 176.5 278.43 71.17 282.7 124.3 291.9 223.0 300.7 231.0 296.7 165.6 149.3 98.0 213.5 97.5 73.3 86.8 317.7 307.4 285.6 78.0 319.5 241.3 75.8 72.8 273.2 272.8 302.7 281.5 299.6 270.3 176.1 169.84 dip angle (degrees) 49.9 63.4 57.9 48.3 26.5 40.1 39.1 20.0 82.8 83.3 48.7 18.1 42.81 34.2 76.7 49.1 39.2 23.4 27.2 32.9 54.3 64.2 65.6 50.1 34.0 78.3 75.0 44.0 47.0 39.5 57.5 68.3 42.8 41.6 70.4 68.2 39.4 47.8 24.8 22.7 24.6 26.6 63.2 47.02 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page.-2 of 3

Fracture Orientations Interpreted from MW-53 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw53i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 109.67 0.31 31.98 less-open 110.19 310.4 33.0 less-open 110.61 302.7 42.1 less-open 110.80 313.3 39.0 less-open 111.13 301.4 36.0 less-open 111.56 281.4 30.2 less-open 113.18 282.1 36.0 less-open 113.37 266.8 29.7 less-open 114.51 294.1 17.0 less-open 114.95 321.5 38.6 less-open 116.43 306.7 46.2 less-open 116.66 318.2 42.1 less-open 117.27 312.4 39.0 less-open 117.44 281.6 33.8 less-open 117.78 257.5 27.7 less-open 118.40 306.9 19.2 less-open 119.38 309.7 35.5 less-open 119.61 61.3 90.0 less-open 124.11 161.2 9.3 less-open 0

Page'3 of 3

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw54i.xls depth (feet) 20.71 21.20 21.41 21.52 22.36 22.60 22.79 23.14 23.32 23.37 23.41 23.66 25.25 25.82 26.11 26.45 27.60 28.65 31.48 31.80 32.45 32.53 32.65 32.97 33.16 33.45 33.59 33.79 33.98 34.40 34.51 34.82 35.39 35.54 35.55 36.28 37.22 37.66 38.47 38.76 39.40 394 39.82 41.26 down-dip compass azimuth (degrees) 47.8 70.2 54.9 58.1 74.3 55.1 74.3 85.2 245.7 231.5 235.2 65.8 223.6 252.3 304.8 256.1 60.1 62.8 141.7 303.4 304.8 269.0 110.7 101.1 98.9 80.5 85.1 85.1 85.4 86.7 104.5 79.2 115.7 98.3 127.1 88.5 90.2 94.0 299.5 278.2 65.4 229.8 99.8 247.7 dip angle (degrees) 68.3 57.6 53.2 52.1 52.4 64.9 44.7 61.3 39.5 26.7 19.8 70.3 31.0 6.3 5.3 8.1 74.7 43.1 64.5 55.2 18.9 18.4 68.5 64.5 68.5 72.4 71.5 72.4 72.0 66.8 65.7 34.7 71.0 60.0 70.7 70.9 80.1 75.4 45.9 38.4 66.8 28.7 67.3 42.4 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

Pagel1 of 10

Fracture Orientations Interpreted from MW-54 Acoustic.Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 43.44 356.7 68.7 less-open 43.64 96;9 71.8 less-open 43.64 75.2 61.1 less-open 44.43 112.5 20.7 less-open 45.99 285.6 67.6 less-open 47.02 312.1 76.5 less-open 48.78 90.7 76.9 less-open 49.92 93.2 75.5 less-open1 50.11 95.55 65.96 less-open, 50.18 137.24 39.76 less-open!

50.30 97.0 71.4 less-open' 50.74 101.8 66.8 less-open!

51.21 91.8 67.2 less-open, 52.70 213.1 34.3 less-openi 53.21 97.7 58.9 less-open' 53.26 126.7 17.8 less-openi 54.21 173.1 11.4 less-openI 54.29 254.6 4.7 less-open!

55.13 116.4 66.0 less-open 55.52 117.7 61.3 less-open 55.82 110.5 56.9 less-open' 56.38 99.6 55.3 less-open' 56.70 102.4 65.5 less-open 57.66 75.8 76.0 less-open' 58.87 345.5 32.6 less-open' 59.20 325.5 60.1 less-open 59.43 110.4 38.7 less-open' 59.56 334.4 58.7 less-open 60.81 76.6 50.6 less-open' 61.18 322.9 63.1 less-open 61.48 289.3 69.8 open I

61.77 292.6 54.4 less-open 62.54 342.7 40.4 less-open 62.90 346.7 36.8 less-open 64.24 316.9 21.8 less-open 64.90 131.8 76.8 less-openr 65.14 129.3 75.3 less-opern 66.50 315.0 67.5 less-open 67.36 0.6 51.5 less-op en 68.03 353.27 59.96 less-operi 68.45 346.94 56.72 less-open 68.52 358.3 70.8 less-open' 68.92 340.8 74.2 less-operi 69.29 343.9 64.2 less-op enr Page 2 of 10

Fracture Orientations Interpreted from MW-54 Acoustic.Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls depth (feet) 69.38 70.25 70.72 70.86 71.09 71.27 72.00 72.19 72.71 73.48 74.00 74.48 75.56 76.13 76.24 77.22 77.25 77.43 78.78 79.9 80.4 80.97 81.31 82.49 84.73 85.38 86.44 87.15 87.27 88.01 88.18 88.95 89.87 90.03 90.32 90.45 91.5 91.8 92.37 92.5 93.33 93.85 95.47 96.07 down-dip compass azimuth (degrees) 105.2 97.8 115.4 342.3 307.6 324.1 106.8 104.2 108.2 100.3 101.8 106.8 279.3 320.9 102.1 106.1 97.79 111.9 108.2 208.0 200.9 197.1 151.8 64.7 201.1 342.2 330.2 354.5 343.5 326.4 323.1 114.6 330.1 356.9 6.4 90.1 330.31 312.63 147.5 345.8 150.1 147.9 267.1 119.9 dip angle (degrees) 53.7 60.2 63.4 51.5 43.8 54.9 72.3 69.3 66.6 68.3 67.2 74.3 71.4 75.6 65.0 42.62 65.54 59.8 82.2 54.9 43.2 50.5 36.7 38.6 55.5 68.5 76.1 48.7 48.6 60.7 54.6 72.2 66.8 60.7 67.8 22.3 61.41 54.48 74.6 57.4 65.9 76.8 37.5 57.9 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page; 3 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 97.15 306.9 64.7 less-open 97.62 145.05 64.89 less-open 97.65 297.43 63.7 less-open 97.78 126.9 32.0 less-open 98.28 89.7 49.3 less-open 98.33 203.7 41.3 less-open 98.89 117.7 79.7 less-open 100.31 90.0 64.9 less-open 101.02 140.4 72.7 less-open 101.48 133.7 59.9 less-open 101.99 340.7 68.1 less-open 102.21 86.5 58.4 less-open 102.57 97.69 54.19 less-open 102.96 88.35 57.77 less-open 103.22 93.9 64.2 less-open 104.37 130.5 66.3 less-open 105.64 182.9 60.3 less-open 105.7 296.0 71.7 less-open 106.64 128.6 50.2 less-open 106.65 300.8 72.4 less-open 107.08 301.8 72.0 less-open 107.56 285.5 41.0 less-open 107.82 284.9 58.4 less-open 108.11 137.9 49.5 less-open 108.41 143.9 56.2 less-open 108.86 280.2 49.5 less-open 109.19 145.8 47.1 less-open 109.71 291.7 64.6 less-open 109.73 117.7 47.4 less-open 109.97 129.3 58.5 less-open 110.15 129.6 63.3 less-open 110.52 131.5 64.9 less-open 110.85 147.7 54.2 less-open 111.47 144.8 67.6 less-open 111.78 125.0 66.1 less-open 112.62 320.3 62.8 less-open 112.89 327.8 53.9 less-open 113.88 105.5 67.5 less-open 114.08 108.9 61.8 less-open 115.33 154.1 68.2 less-open 115.48 156.6 67.9 less-open 116.64 145.5 37.2 less-open 117.38 117.4 65.1 less-open0 117.96 100.1 57.8 less-open PageA of 1.0

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site S Buchanan, NY Prepared for: GZA 105836 - mw54i.xls depth (feet) 118.31 118.44 118.71 119.21 119.85 120.39 120.72 120.78 121.03 121.93 122.49 122.66 122.85 123.08 123.32 123.44 S 123.94 123.96 124.35 124.59 124.66 124.87 125.01 125.49 125.8 126.33 127.48 129.57 129.83 130.24 130.68 130.89 131.08 131.82 133.03 133.16 133.99 135.09 136.35 137.05 137.38 S 137.47 137.58 137.78 down-dip compass azimuth (degrees) 93.8 97.3 110.0 128.0 126.4 131.7 126.9 193.1 114.6 137.7 153.7 299.4 149.8 300.8 177.6 309.9 142.8 283.4 243.0 245.8 253.4 114.2 111.6 113.3 164.6 152.7 297.9 107.9 236.0 103.3 96.4 93.06 106.7 123.8 314.0 308.6 129.5 331.1 111.8 98.6 74.1 115.1 95.4 88.1 dip angle (degrees) 55.9 56.6 55.2 67.3 61.4 54.2 64.2 43.6 62.1 66.0 75.5 77.0 80.7 73.4 46.3 60.1 60.1 60.4 32.4 33.1 34.8 51.7 80.2 42.0 74.0 75.7 46.9 45.4 55.1 62.9 57.97 38.06 51.1 41.6 29.5 48.8 55.8 56.6 49.4 57.6 43.6 63.8 51.2 56.6 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 5,of. 10

Fracture Orientations Interpreted from MW-54 Acoustic: Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 137.9 337.5 71.8 less-open 137.97 88.8 68.3 less-open 138.09 295.0 53.4 less-open 138.66 119.7 40.0 less-open 138.94 99.2 50.4 less-open 139.27 122.5 64.1 less-open 139.51 96.5 59.2 less-open 139.57 286.5 61.6 less-open 139.59 124.8 45.9 less-open 139.97 68.8 58.3 less-open 140.15 169.3 49.5 less-open 140.41 44.7 21.1 less-open 140.45 226.2 31.8 less-open 140.5 83.7 63.1 less-open 140.74 219.4 63.0 less-open 141.23 244.3 26.9 less-open 142.24 185.0 36.8 less-open 142.43 119.6 78.1 less-open 144.42 123.5 38.1 less-open 144.49 113.1 67.7 less-open 144.61 114.4 39.6 open 144.84 124.6 41.3 open 145.01 115.8 44.3 open 145.55 95.2 44.0 less-open 145.86 114.4 41.5 less-open 146.02 104.1 46.0 less-open 146.14 97.6 44.5 less-open 146.96 175.8 75.4 less-open 147.41 187.5 36.8 less-open 148.09 325.3 56.8 less-open 148.52 214.8 60.0 less-open 148.68 196.9 35.0 less-open 148.82 178.9 53.2 less-open 149.33 188.4 40.3 less-open 149.42 236.3 48.3 less-open 149.49 183.0 40.8 less-open 149.8 138.8 68.3 less-open 150.35 81.1 49.7 less-open 150.59 90.2 44.7 less-open 150.88 122.6 69.4 less-open 151.01 104.1 62.2 less-open 151.11 357.7 80.9 less-open 151.24 101.0 40.6 less-open 151.41 109.44 47.09 less-open Page6 of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site O

Buchanan, NY Prepared for: GZA 105836 - mw54iLxls depth (feet) 151.51 151.56 151.94 152.29 152.67 152.9 153 154.36 155.49 155.63 155.69 155.85 156.47 156.79 156.99 157.19 157.47 158.23 158.56 158.81 159 159.12 159.25 159.38 159.42 159.52 160.2 160.44 161.52 161.59 162.09 162.15 162.29 162.66 162.79 163.16 163.81 164.21 164.5

.164.67 166.59 166.77 down-dip compass azimuth (degrees) 326.3 111.92 122 141.66 136.7 115.89 128.63 80.63 97.7 74.18 108.38 149.48 141.61 144.32 138.16 181.39 155.01 137.27 117.06 112.25 95.88 92.67 118.76 106.72 199.16 102.96 200.96 96.59 174.24 109.22 97.62 101.72 67.69 189.75 102.22 270.05 112.42 257.7 41.53 75.9 111.68 136.22 110.49 103.34 dip angle (degrees) 82.15 50.04 34.76 34.49 19.09 49.52 48.23 51.46 80.56 55.48 80.21 55.4 44.08 44.71 44.02 22.46 35.6 24.69 34.56 54.24 60.66 66.08 63.56 64.15 54.36 57.88 54.21 65.17 23.28 72.43 61.34 72.06 48.77 62.14 55.01 67.01 79.94 23.17 67.27 76.37 76.13 76.2 70.45 56.55 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page.? of, 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 167.12 115.01 51.46 less-open 167.78 90.05 48.31 less-open 168.4 104.05 45.28 less-open 168.58 114.26 45.14 less-open 168.8 120.57 50.57 less-open 168.84 299.18 72.09 less-open 169.27 347.29 44.11 less-open 169.48 336.05 39.28 less-open 169.61 126.83 57.28 less-open 170.51 108.91 75.55 less-open 170.9 119.85 55.09 less-open 171.09 145.65 57.06 less-open 172.27 260.45 69.61 less-open 172.59 266.38 74.6 less-open 172.65 301.97 54.36 less-open 173.22 107.06 57.71 less-open 173.55 96.22 57.95 less-open 173.82 319.98 54.15 open 173.9 282.49 63.83 open 174.28 304.29 70.31 open 175.46 99.29 65.69 open 175.68 100.21 58.12 open 176.3 107.58 61.63 less-open 176.53 114.7 60.28 less-open 177.18 131.56 74.71 less-open 177.33 133.76 69.94 less-open 177.56 127.71 70.44 less-open 177.71 115.46 74.43 less-open 178.62 205.95 58.43 less-open 178.62 356.98 34.55 less-open 179.28 135.8 57.17 less-open 179.55 357.58 85.59 less-open 179.58 125.84 51.24 less-open 179.94 111.69 32.09 less-open 180.6 102.82 40.97 less-open 181.37 174.85 68.71 less-open 181.72 337.5 38.08 less-open 181.84 37.21 32.02 less-open 181.94 215.29 69.44 less-open 182.26 252.59 30.92 less-open 182.43 138.73 66.74 less-open 183.02 113.3 71.43 less-open 183.3 353.99 74.75 less-open 183.5 106.78 73.85 less-open Pa'ge 8, of -.10

Fracture Orientations Interpreted from MW-54 Acoustic, Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw54i.xls depth (feet) 183.85 183.9 184.48 184.71 185.31 185.43 185.58 186.25 186.28 186.63 186.71 187.43 187.66 187.71 187.98 189.96

.189.98 190.27 190.76 191.04 192.42 193.1 193.48 193.95 194 194.17 194.72 194.74 194.94 195.41 195.58 195.95 196.75 196.9 197.52 197.68 197.8 198.26 198.32 199.48 200.29 200.52

.200.83 201.07 down-dip compass azimuth (degrees) 348.1 88.16 324.09 104.66 143.73 312.61 202.59 323.48 351.99 108.02 349.1 85.19 191.18 133.74 120.92 174.43 172.49 163.97 201.7 146.33 306.81 101.31 132.81 201.15 186.46 101.92 151.66 180.84 185.74 320.64 277.04 107.66 131.09 319.35 305.11 106.8 301.62 165.02 144.69 49.16 118.03 264.76 290.39 302.31 dip angle (degrees) 56.02 75.46 45.12 50.09 62.28 58.3 43.8 70.49 49.28 73.31 79.18 64.98 39.72 56.02 63.88 53.43 83.74 44.03 48.33 46.61 74.35 40.74 42.37 59.7 64.05 63.2 21.52 70.53 66.82 38.82 70.22 36.37 77.23 73 62.94 43.25 57.49 82.73 75.02 41.62 33.85 50.98 44.84 50.48 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open open less-open less-open Page, 9of 10

Fracture Orientations Interpreted from MW-54 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw54i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 201.24 278.07 43.53 less-open 201.72 88.77 51.77 less-open 201.89 111.94 55.94 less-open 201.97 91.13 81.6 open 202.85 134.08 53.6 less-open 203.08 131.77 89.57 less-open 203.46 271.73 89.31 less-open 203.68 268.77 89.79 less-open 203.94 289.97 89.99 less-open 204.3 99.47 89.68 less-open Page i0-of 10

Fracture Orientations Interpreted from MW-55 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw55i.xls depth (feet) 12.43 13.14 13.38 13.89 14.29 14.61 15.20 15.79 15.91 16.75 16.91 17.09 17.21 18.38 19.43 19.75 O 20.01 20.45 20.52 20.97 21.94 22.08 23.31 23.55 23.73 24.09 24.50 24.83 25.04 25.29 25.62 26.15 26.95 27.61 27.66 28.36 29.50 30.14 32.29 32.64 32.73 33.07 33.23 33.26 down-dip compass azimuth (degrees) 73.7 63.9 48.5 316.3 137.6 113.4 170.0 143.1 161.0 226.4 194.7

.161.4 142.2 73.2 29.1 108.2 224.4 203.3 51.6 328.2 270.5 310.2 194.2 316.6 246.0 140.7 152.3 174.2 249.8 160.3 200.1 138.5 222.6 197.7 49.2 269.6 255.6 119.8 151.6 85.1 83.2 112.3 94.4 313.6 dip angle (degrees) 62.7 66.6 66.9 61.1 60.9 54.5 58.7 50.6 79.3 67.8 78.6 60.0 69.7 70.2 43.8 38.3 28.0 24.3 61.4 61.3 40.0 75.2 37.0 68.4 21.6 39.0 43.3 24.4 26.7 30.5 20.9 24.3 31.1 49.5 44.1 68.4 22.9 40.4 39.7 52.9 36.8 73.0 54.6 82.7 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

Page 1-of 4

Fracture Orientations Interpreted from MW-55 Acoustic Televiewe o

Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw55i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 33.57 141.2 63.3 less-open 34.29 315.6 68.3 less-open 34.46 168.6 63.4 less-open 35.59 151.6 72.1 less-open 35.61 290.2 75.7 less-open 36.09 310.1 39.9 less-open 37.59 244.8 53.0 less-open 37.80 140.9 78.2 less-open 38.51 114.6 78.5 less-open 39.67 308.4 69.0 less-open 41.54 185.5 53.9 less-open 43.38 165.0 63.7 less-open 44.26 177.8 63.7 less-open 44.96 226.7 59.0 less-open 45.70 23.9 33.5 less-open 45.89 148.2 75.6 less-open 46.07 203.62 70.35 less-open 46.13 332.99 79.09 less-open 46.72 102.0 45.2 less-open 47.04 105.6 51.3 less-open 47.46 93.7 21.0 open 48.73 70.8 68.1 less-open 49.35 249.2 33.3 less-open 49.84 214.1 12.9 less-open 50.99 283.2 55.2 less-open 51.23 315.3 49.1 less-open 51.40 124.3 14.2 less-open 51.59 317.6 52.7 less-open 52.45 85.7 36.4 less-open 52.91 101.0 66.5 less-open 53.44 80.8 43.1 open 53.61 91.6 43.6 open 54.48 287.2 38.3 less-open 55.31 274.9 16.6 less-open 56.84 63.9 58.8 less-open 57.34 72.1 63.9 less-open 57.78 97.0 58.5 less-open 58.59 303.4 63.0 less-open 58.98 288.8 62.5 4ess-open 59.13 179.1 63.4 less-open 59.90 321.0 41.8 less-open 60.36 175.2 44.3 less-open 60.44 315.2 56.9 less-open 60.45 78.9 61.5 less-open Page 2 of 4

Fracture Orientations Interpreted from MW-55 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw55i.xls depth (feet) 60.68 61.30 61.41 61.55 61.73 61.82 62.24 62.47 62.70 63.25 63.38 63.50 63.72 64.04 64.38 64.53 64.61 64.90 64.97 65.01 65.51 65.75 65.86 66.06 66.28 66.74 66.97 67.33 67.77 68.07 68.36 68.58 69.24 69.78 69.85 70.55 71.09 71.44 71.75 72.14 72.41 73.92 74.06 74.29 down-dip compass azimuth (degrees) 96.1 75.6 103.2 254 74.96 290.3 268.3 89.2 311.2 304.4 87.5 325.4 238.9 95.2 87.1 280.0 295.5 74.6 85.4 313.3 359.9 170.2 324.3 105.7 62.5 340.3 358.6 5.8 1.3 5.4 338.9 207.9 302.5 121.9 201.0 295.3 270.1 187.9 203.4 93.1 187.4 255.3 178.9 162.8 dip angle (degrees) 73.6 75.9 77.8 73.52 65.95 41.2 51.6 50.8 43.6 37.5 51.2 55.4 29.7 73.6 68.2 51.7 48.5 31.0 70.3 78.0 52.5 78.9 43.7 51.6 68.9 49.6 55.5 56.8 54.6 46.9 47.3 71.8 48.3 57.0 60.4 38.8 26.7 48.3 59.7 65.7 56.0 27.0 59.6 60.1 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page -3 of-4

Fracture Orientations Interpreted from MW-55 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw55i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 74.74 330.0 46.9 less-open 75.26 332.0 52.9 less-open 75.96 307.2 5.1 less-open 76.15 296.8 7.5 less-open 76.57 174.6 12.0 less-open Page40of-4

Fracture Orientations Interpreted from MW-56 Optical-& Acoustic Televiewer Logs Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw56i.xls depth (feet) 31.02 32.45 32.56 32.91 33.01 33.68 35.65 36.90 37.81 38.79 39.83 40.01 41.21 41.71 42.54 42.60 43.33 43.83 44.42 44.83 45.02 45.29 45.70 46.96 47.05 48.10 48.39 50.31 51.62 51.70 51.78 51.94 52.50 52.84 53.20 53.68 54.13 56.09 57.17 57.20 57.22 57.59 57.62 58.17 down-dip compass azimuth (degrees) 193.2 172.6 223.5 228.3 11.8 338.5 144.0 147.2 346.6 5.3 85.6 115.0 13.2 301.2 1.9 155.1 79.6 0.8 1.0 176.1 4.3 6.9 8.3 173.3 10.0 166.9 4.4 212.2 188.2 329.9 155.6 10.3 6.0 198.0 220.7 341.3 121.1 330.9 351.7 320.9 203.7 200.8 290.5 207.9 dip angle (degrees) 77.7 51.9 79.8 79.4 73.6 40.3 20.1 63.8 49.7 73.1 30.5 34.2 67.1 52.2 59.5 64.4 20.0 65.0 68.8 66.8 65.8 70.5 73.7 36.4 70.6 17.8 74.6 14.6 3.2 5.7 8.3 9.4 65.7 4.6 62.2 43.8 13.3 38.3 52.6 47.7 37.4 70.3 14.6 78.3 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

Page;1,of 3

Fracture Orientations Interpreted from MW-56 Optical-&Acoustic Televiewer Logs Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw56i.xls down'-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 59.12 84.6 8.1 less-open 59.84 119.3 74.4 less-open 60.90 341.3 46.4 less-open 61.10 220.9 68.9 less-open 61.53 223.12 61.57 less-open 61.69 234.02 57.02 less-open 61.80 27.8 9.2 less-open 61.86 147.3 27.2 less-open 62.52 357.3 41.1 less-open 62.52 143.2 67.8 less-open 63.10 274.6 35.7 less-open 63.33 34.3 32.4 less-open 63.94 307.3 36.8 less-open 64.50 303.3 53.4 less-open 65.12 171.8 59.2 less-open 65.40 175.2 58.2 less-open 66.67 328.3 61.1 less-open 67.98 274.2 66.2 less-open 68.04 275.4 62.9 less-open 68.71 230.9 57.0 less-open 69.08 271.2 8.0 less-open 69.29 339.9 7.6 less-open 69.45 173.0 50.2 less-open 69.86 236.5 7.9 less-open 69.97 325.9 18.3 less-open 70.17 276.6 57.6 less-open 70.20 176.3 71.9 less-open 70.33 29.0 45.6 less-open 70.92 294.8 6.0 less-open 71.00 313.7 23.1 less-open 71.02 294.5 65.8 less-open 71.54 277.9 18.2 less-open 71.57 179.0 75.8 less-open 71.68 351.3 39.1 less-open 71.80 19.0 36.1 less-open 72.66 292.75 17.01 less-open 72.85 220.08 79.25 less-open 73.30 224.5 77.9 less-open 73.49 218.8 26.4 less-open 73.79 1.1 32.7 less-open 73.93 171.5 63.2 less-open 74.41 272.7 52.3 less-open 74.73 254.2 45.0 less-open 75.28 142.4 75.3 less-open Page`2_6f-3_

Fracture Orientations Interpreted from MW-56 Optical,& Acoustic Televiewer Logs Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw56i.xls depth (feet) 75.59 75.77 76.08 76.61 76.96 77.04 77.07 77.33 77.53 77.54 78.64 78.80 78.92 79.13 79.25 79.39 79.77 79.96 80.5 80.66 80.75 80.83 80.98 81.11 81.19 81.58 81.72 81.9 83.01 83.93 84.27 84.28 84.59 84.86 85.35 85.61 86.14 86.51 down-dip compass azimuth (degrees) 351.8 206.1 170.7 264.1 258.2 92.8 263.1 170.4 203.97 186.69 161.9 357.0 162.2 171.07 179.42 122.5 255.8 171.5 175.0 178.2 220.7 318.4 178.3 239.4 180.2 181.1 173.8 154.6 185.9 150.2 228.9 341.8 221.0 207.4 235.87 59.54 70.5 215.7 dip angle (degrees) 24.1 60.7 70.9 57.9 57.5 23.8 56.8 49.3 61.43 58.9 71.6 82.9 54.7 80.07 63.94 78.8 40.1 50.8 23.6 71.3 34.8 53.0 78.0 52.6 75.5 72.7 36.1 70.5 80.3 59.4 31.3 67.2 38.6 54.4 62.96 89.93 87.3 89.5 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page:3,of 3

Fracture Orientations Interpreted from MW-57 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw57i.xls depth (feet) 6.17 6.44 6.61 6.88 7.36 7.46 7.75 7.86 8.53 9.12 9.44 10.25 10.52 10.74 10.87 11.03 11.12 11.24 11.41 11.99 12.20 12.70 13.42 15.90 16.34 16.34 17.61 18.44 19.58 19.82 21.17 21.76 22.01 22.85 22.86 23.76 24.19 25.08 25.76 28.16 28.35 29.15 29.71 29.77 down-dip compass azimuth (degrees) 133.4 64.8 300.2 162.4 235.1 41.7 25.6 336.3 345.4 254.4 352.5 45.9 40.1 355.5 15.1 28.8 308.4 332.1 99.0 101.7 356.5 41.0 97.9 314.5 4.4 105.8 355.4 172.2 291.9 90.1 7.9 336.3 266.5 311.4 194.6 343.6 131.9 146.6 169.6 109.9 257.3 115.3 279.9 82.1 dip angle (degrees) 77.5 16.0 5.1 44.0 36.9 16.4 21.9 8.6 16.3 72.8 48.0 29.2 18.0 20.8 31.0 25.5 26.8 27.3 56.1 61.8 18.4 11.0 68.3 16.3 15.5 80.4 16.2 55.9 32.1 67.9 26.3 15.9 22.1 32.7 64.5 47.0 59.8 68.2 69.0 59.0 73.2 73.5 20.8 74.8 interpreted planar feature category less-open open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

0 Pagia-1 of 3,

Fracture Orientations Interpreted from MW-57 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw57i.xls depth (feet) 30.12 30.46 30.95 31.81 32.02 32.04 32.37 32.5 32.72 32.87 32.96 33.37 33.37 34.23 34.57 35.30 35.59 35.64 35.81 36.08 36.37 36.53 36.73 36.79 36.97 37.16 38.09 38.31 38.45 38.76 38.85 38.96 39.15 39.38 39.64 39.80 40.03 40.7 41.35 41.44 42.13 43.03 43.06 43.26 down-dip compass azimuth (degrees) 76.8 90.7 94.5 143.4 129.2 331.4 291.45 247.4 115.1 284.4 286.0 89.9 287.5 298.4 328.7 292.2 105.1 318.2 311.9 303.6 311.8 307.1 87.2 312.2 287.1 307.1 317.2 316.3 126.8 306.4 320.7 311.7 306.6 325.6 316.6 322.6 125.5 215.86 57.99 214.6 121.6 30.7 312.4 324.9 dip angle (degrees) 74.2 77.5 73.0 77.6 73.3 37.0 33.23 80.52 35.5 60.6 38.2 73.8 73.5 76.8 63.4 46.1 48.3 55.7 21.7 53.3 47.1 53.3 69.4 44.7 47.9 42.9 42.2 56.1 77.5 66.3 65.4 63.9 32.2 53.3 62.8 65.5 76.3 52.44 39.92 46.7 57.1 15.2 74.4 28.7 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page.2 of 3

Fracture Orientations Interpreted from MW-57 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw57i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 43.37 290.4 67.5 less-open 43.66 115.8 52.1 less-open 43.78 83.3 82.9 less-open 43.84 92.6 53.7 less-open 44.11 72.2 66.9 less-open 44.13 349.5 76.3 less-open 44.33 85.8 78.0 less-open 44.91 327.7 89.7 less-open 45.17 309.9 89.3 less-open 45.73 305.7 89.7 less-open Page -3 of 3'

Fracture Orientations Interpreted from MW-58 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw58i.xls depth (feet) 16.76 16.95 17.41 17.82 17.99 18.30 18.72 18.75 18.86 19.14 19.28 19.43 19.96 20.28 20.34 20.53 20.64 20.94 21.03 21.11 21.30 21.56 21.81 21.97 22.40 22.94 23.23 23.38 23.49 23.92 24.04 24.40 25.06 25.10 25.16 25.31 25.38 26.18 26.28 26.46 26.94 O 27.37 28.08 28.36 down-dip compass azimuth (degrees) 344.0 340.6 171.3 357.3 349.1 11.6 204.5 20.8 3.6 15.5 352.8 344.0 164.5 335.1 162.4 170.9 340.2 158.1 345.1 351.1 351.7 342.8 354.9 343.2 314.6 320.7 307.1 133.0 333.7 325.0 118.5 319.2 121.2 326.9 338.6 117.1 328.5 317.0 322.3 342.8 120.7 345.2 341.1

.176.3 dip angle (degrees) 36.5 42.7 66.7 67.1 58.7 53.0 72.9 32.8 67.5 29.9 34.8 29.1 66.1 57.0 70.2 62.2 35.2 65.8 31.5 34.7 41.8 41.9 39.1 39.8 55.7 26.7 49.5 73.2 49.8 45.9 71.6 43.7 63.5 63.3 56.7 68.6 61.5 61.1 45.0 46.6 65.7 58.7 59.6 62.7 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

P~age 1.

1.of 3

Fracture Orientations Interpreted from MW-58 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw58i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 28.98 339.7 58.4 less-open 29.42 328.8 40.7 less-open 30.06 319.5 43.1 less-open 30.77 312.6 42.0 less-open 31.20 149.6 64.0 less-open 32.00 311.1 36.1 less-open 32.46 313.7 32.7 less-open 33.06 290.8 35.1 less-open 33.20 300.3 28.6 less-open 33.56 310.0 32.1 less-open 34.03 339.91 41.14 less-open 34.37 132.58 60.75 less-open 34.68 282.7 29.2 less-open 35.02 113.0 66.1 less-open 35.37 102.5 62.2 less-open 35.84 100.5 67.9 less-open 35.92 332.5 66.3 less-open 36.38 312.3 43.3 less-open 36.52 111.3 64.8 less-open 36.60 302.6 53.1 less-open 37.10 312.6 45.5 less-open 37.22 326.6 40.7 less-open 37.58 323.4 39.8 less-open 38.17 314.9 50.4 less-open 38.25 314.7 47.1 less-open 38.40 311.2 58.6 less-open 38.82 332.8 32.9 less-open 39.06 95.3 70.2 less-open 39.22 298.1 40.0 less-open 39.54 297.3 47.8 less-open 39.94 327.2 56.5 less-open 40.08 96.7 70.8 less-open 40.62 94.2 70.8 less-open 41.16 313.6 32.5 less-open 41.35 78.7 70.7 less-open 41.53 296.7 24.6 less-open 42.27 305.6 52.1 less-open 42.70 333.9 42.2 less-open 43.04 301.5 47.4 less-open 43.16 295.0 52.6 less-open 43.74 316.6 46.6 less-open 44.46 101.8 63.02 less-open 44.5 335.9 45.32 less-open0 45.32 342.3 39.0 less-open Pagei-2 of 3

Fracture Orientations Interpreted from MW-58 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw58i.xls depth (feet) 46.27 46.98 48.89 52.82 53.46 53.77 54.36 56.84 57.63 58.41 59.02 59.22 59.63 60.77 60.99 61.41 O 61.77 63.25 64.06 64.34 64.38 64.81 64.92 65.13 65.22 65.71 65.96 66.21 66.33 66.68 66.94 67.26 67.89 67.96 68.07 68.28 68.93 70.24 down-dip compass azimuth (degrees) 301.2 310.0 351.1 96.6 107.2 107.0 305.0 290.2 295.5 162.9 105.5 302.9 282.8 297.1 101.8 122.4 103.0 301.09 71.9 143.2 319.0 291.8 181.4 177.0 170.8 178.8 323.2 110.7 107.7 288.1 111.8 115.3 100.5 108.1 305.7 108.8 95.9 192.9 dip angle (degrees) 40.8 34.9 22.6 58.6 65.3 65.8 38.6 40.6 50.2 73.1 63.5 61.9 64.5 61.0 66.7 63.8 67.9 37.77 66.14 63.6 35.9 41.4 67.9 69.9 68.1 70.2 53.5 61.3 65.6 55.7 59.3 67.2 69.9 71.0 53.9 72.9 65.1 6.4 interpreted planar feature category less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page,.3.of 3

Fracture Orientations Interpreted from MW-59 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: OZA 105836 - mw59i.xls depth (feet) 20.77 21.69 21.76 23.51 23.68 24.14 24.14 24.43 24.77 24.99 25.11 25.19 25.33 25.51 26.12 26.19 26.79 26.88 26.94 27.18 27.25 27.30 27.34 27.99 28.14 28.45 28.83 29.09 29.40 29.43 29.81 30.13 30.19 30.43 30.56 31.17 31.54 31.78 32.04 32.15 32.34 32.46 32.59 32.83 down-dip compass azimuth (degrees) 253.8 221.7 213.1 225.7 217.0 220.2 219.1 132.3 354.0 207.9 357.9 150.9 135.7 147.6 142.0 147.3 188.0 135.2 324.5 284.7 141.6 187.5 129.3 123.9 159.0 229.4 132.6 135.8 120.2 317.1 141.3 324.8 148.0 313.3 317.5 195.2 183.5 304.2 305.6 114.5 120.6 120.9 211.3 123.8 dip angle (degrees) 29.3 62.6 72.2 60.8 69.7 78.0 75.4 48.1 50.4 77.2 45.9 41.4 34.0 51.7 57.0 58.4 84.0 59.9 39.0 46.2 37.0 85.0 48.1 59.1 46.2 47.1 65.8 51.6 53.7 38.4 54.8 43.2 61.5 41.8 45.1 41.0 38.5 45.4 46.4 65.7 57.4 58.8 64.0 68.3 interpreted planar feature category open less-open less-open open

.less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

Page 1 Tof 47

Fracture Orientations Interpreted from MW-59 Acoustic :Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw59i.xls depth (feet) 33.54 34.06 34.16 34.27 34.99 35.68 36.78 37.07 37.63 37.88 38.22 38.64 39.66 41.65 42.24 42.47 42.79 42.90 43.11 43.37 43.47 43.52 43.68 44.60 44.66 45.10 45.95 46.44 46.44 46.69 47.60 47.99 48.25 48.37 48.46 48.67 49.41 49.75 50.23 50.41 50.57 50.93 51.43 51.65 down-dip compass azimuth (degrees) 127.6 204.3 7.1 199.7 340.4 182.9 116.3 189.0 137.0 132.2 198.2 175.4 165.5 339.1 212.49 254.48 156.3 157.8 146.5 120.2 180.5 197.0 179.6 182.0 214.0 195.7 167.4 325.3 186.8 208.9 338.7 329.3 135.7 157.4 322.6 140.6 310.2 305.3 343.3 328.9 211.7 135.0 332.3 323.8 dip angle (degrees) 45.9 63.6 63.4 46.9 69.6 55.9 60.4 59.3 55.1 56.9 70.9 62.1 42.6 43.9 15.37 49.31 54.4 45.8 23.5 47.9 18.6 66.7 40.7 45.7 14.0 65.7 51.6 50.5 38.4 60.7 42.2 45.2 55.0 59.2 43.1 56.8 35.3 36.4 42.2 40.3 45.0 48.0 42.3 30.0 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 2,of 4

Fracture Orientations Interpreted from MW-59 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw59i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 51.78 320.0 42.8 less-open 52.16 314.36 42.53 less-open 52.49 203.3 60.67 less-open 52.93 320.0 36.1 less-open 53.06 193.1 66.2 less-open 53.31 338.0 39.4 less-open 53.48 319.9 36.0 less-open 54.20 324.8 34.5 less-open 55.03 213.7 71.5 less-open 55.31 203.4 70.2 less-open 55.44 326.6 35.9 less-open 55.49 208.0 66.2 less-open 55.66 297.7 31.1 less-open 56.74 311.9 18.1 less-open 57.18 330.7 39.2 less-open 57.30 318.3 33.7 less-open 57.46 324.0 47.3 less-open 57.80 189.0 74.8 less-open 58.15 319.6 26.6 less-open 58.23 312.2 31.6 less-open 58.27 309.7 48.4 less-open 58.42 314.4 36.1 less-open 58.76 186.1 56.0 less-open 59.88 335.6 36.2 less-open 60.12 351.1 40.1 less-open 60.31 329.1 33.6 less-open 60.42 340.0 38.4 less-open 60.64 184.3 73.4 less-open 60.66 323.3 34.6 less-open 61.01 104.0 71.5 less-open 61.48 116.1 66.1 less-open 61.96 328.3 40.4 less-open 62.14 144.1 62.3 less-open 62.6 12.0 9.6 less-open 62.94 310.4 22.3 less-open 63.2 134.8 66.7 less-open 63.23 313.5 51.3 less-open 63.81 123.0 26.0 less-open 65.41 297.1 30.2 less-open 65.5 301.1 31.0 less-open 67.42 158.5 60.1 less-open 67.66 320.2 40.3 less-open 67.92 321.8 41.2 less-open 68.12 318.8 41.3 less-open Page 3of 4

Fracture Orientations Interpreted from MW-59 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw59i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 70.44 321.5 44.9 less-open 70.83 305.9 45.6 less-open 70.92 310.8 45.1 less-open 70.98 312.44 47.62 less-open 71.18 317.72 39.27 less-open 71.32 306.7 41.6 less-open 71.44 306.6 37.3 less-open 72.32 304.0 39.4 less-open 73.58 120.6 61.9 less-open 73.71 33.5 13.6 less-open 74.25 315.6 22.7 less-open 74.72 304.5 29.3 less-open 75.17 341.8 87.4 less-open 76.25 315.8 87.6 less-open Page 4-,of 4

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls depth (feet) 10.40 11.96 12.08 13.20 14.40 14.49 16.02 16.86 18.00 19.74 20.11 20.46 22.94 27.05 29.75 36.27 36.47 36.99 37.39 38.54 39.31 39.73 40.60 43.20 49.41 50.09 52.30 52.64 52.82 53.12 53.64 54.14 54.14 54.42 55.83 55.86 56.89 57.06 57.62 58.23 58.78 59.00 60.03 60.07

'down-dip compass azimuth (degrees) 296.3 104.0 300.3 304.0 275.6 143.9 103.6 115.8 282.9 37.5 249.5 112.6 315.4 134.0 99.8 221.8 331.5 302.7 323.2 24.7 118.5 110.4

.125.3 205.1 132.4 147.4 313.7 9.1 336.8 354.1 331.3 273.9 258.6 341.7 324.8 253.8 325.8 303.9 326.3 327.4 336.8 351.8 306.9 147.5 dip angle (degrees) 36.1 35.7 50.7 38.7 62.4 34.6 57.7 59.7 61.1 49.1 31.2 47.3 51.9 35.0 53.9 56.7 61.0 48.2 39.3 13.4 63.4 59.4 72.0 57.5 45.1 86.1 42.3 31.1 41.9 61.8 23.5 67.7 59.2 22.1 58.6 4.9 42.0 58.3 73.2 74.8 77.8 76.3 52.6 52.1 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less,-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open open less-open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

Pa g 61of 7.

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw60i.xls depth' (feet) 60.65 60.67 61.21 61.99 62.23 63.97 64.16 64.25 64.32 64.33 65.01 65.45 66.44 68.01 68.29 69.39 69.59 69.83 70.53 70.67 71.50 71.80 72.77 73.78 74.10 74.40 74.83 74.95 75.20 75.96 76.39 77.23 77.34 78.12 78.69 84.49 84.71 85.36 90.85 91.38 91.64 O 92.9 93.3 93.73 down-dip compass azimuth (degrees) 336.8 148.9 109.9 330.3 325.0 307.1 325.5 311.8 201.8 298.9 197.35 312.86 307.7 323.4 300.2 126.8 131.2 292.7 309.2 103.4 323.6 319.6 319.5 324.9 309.6 274.5 80.5 185.8 186.9 315.5 323.4 353.9 38.5 284.1 220.5 318.3 324.9 303.7 31.4 158.4 310.8 169.38 191.92 172.1 dip angle (degrees) 61.9 70.3 36.2 53.0 59.4 63.1 68.7 49.4 67.6 45.9 72.97 63.37 63.6 77.1 74.1 42.4 39.7 67.5 70.3 53.9 70.7 63.5 60.2 59.6 61.8 67.2 15.5 65.6 68.5 46.2 42.6 17.3 21.2 68.3 79.9 48.1 56.1 48.1 31.4 73.3 32.4 80.19 32.75 66.6 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page-2,of 7

Fracture Orientations Interpreted from MW-60 Acoustic Televie'wer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 93.81 232.1 45.3 less-open 94.97 303.6 39.1 less-open 95.18 195.9 53.5 less-open 95.39 98.1 77.3 less-open 96.46 327.0 44.5 less-open 98.00 288.1 68.1 less-open 98.23 311.6 69.6 less-open 99.24 313.0 66.3 less-open 99.43 341.8 64.4 less-open 100.51 267.9 67.9 less-open 100.83 135.4 58.0 less-open 101.41 158.3 26.9 less-open 102.04 151.1 31.3 less-open 102.54 192.9 67.8 less-open 102.94 191.2 79.4 less-open 103.87 209.9 81.2 less-open 104.51 357.4 49.7 less-open 104.85 344.1 46.6 less-open 107.14 93.6 67.0 less-open 107.23 139.0 44.3 less-open 107.82 94.5 19.7 less-open 108.3 126.3 27.6 less-open 108.86 334.8 76.3 less-open 109.35 309.5 70.1 less-open 110.23 319.3 58.7 less-open 110.43 311.4 58.7 less-open 110.61 313.3 59.5 less-open 111.11 192.3 31.1 less-open 111.35 150.0 33.6 less-open 111.84 167.5 66.4 less-open 112.38 148.7 65.4 less-open 113.09 307.1 32.5 less-open 113.72 329.2 31.4 less-open 114.14 111.6 55.3 less-open 116.59 14.3 53.0 less-open 116.89 99.6 66.8 less-open 117.53 117.0 44.7 less-open 117.91 117.7 37.1 less-open 118.37 139.2 38.5 less-open 118.62 120.6 46.7 less-open 119.19 329.5 73.8 less-open 119.59 145.6 50.4 less-open 119.87 143.2 36.5 less-open 120.16 120.86 29.75 less-open Pa ge 3ýof 7

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site O

Buchanan, NY Prepared for: GZA 105836 - mw60i.xls depth (feet) 120.64 122.21 122.37 122.54 122.7 122.93 123.15 123.35 125.48 126.31 127.91 128.72 128.78 129.39 129.83 131.48

.133.43 135.7 136.57 136.69 136.82 137.19 137.34 137.87 138.06 139.39 140.27 140.74 141.43 142.39 142.5 142.63 142.94 145.3 145.38 146.06 146.73 148.94 149.76 150.12 150.35 150.46 150.58 151.1 down-dip compass azimuth (degrees) 118.02 136.9 123.2 126.0 146.6 131.4 130.8 126.0 118.1 139.8 141.48 332.45 144.1 155.9 133.6 119.5 165.6 132.4 143.5 122.1 123.7 132.7 119.4 146.9 176.7 150.8 131.2 133.9 106.5 141.5 142.2 149.9 137.2 127.9 130.2 151.5 137.1 321.3 133.2 129.0 130.7 119.7 116.2 157.0 dip angle (degrees) 67.72 29.9 41.5 29.7 35.6 33.7 42.4 29.9 57.0 35.1 38.06 58.01 40.2 53.1 46.7 28.8 33.2 56.3 33.1 31.3 30.3 45.3 46.6 33.0 26.3 33.4 34.9 34.2 40.4 33.0 28.7 27.8 30.1 31.1 30.1 33.2 34.0 80.5 33.0 35.1 38.7 35.2 42.8 37.2 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page.4.of 7.

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 151.51 158.6 36.7 less-open 151.62 150.1 34.3 less-open 151.68 146.2 31.7 less-open 151.84 143.7 30.2 less-open 152.01

.143.4 35.1 less-open 152.55 144.5 38.7 less-open 152.81 141.9 37.6 less-open 153.39 134.3 39.4 less-open 153.46 147.9 37.8 less-open 153.74 140.9 38.9 less-open 155.22 117.0 45.1 less-open 155.58 128.6 51.7 less-open 155.66 342.4 34.3 less-open 155.86 124.9 35.6 open 156.17 142.8 35.7 less-open 156.49 123.4 45.6 less-open 156.91 152.7 38.7 less-open 157.09 142.1 37.2 less-open 158.08 133.7 42.1 less-open 158.3 320.2 70.8 less-open 158.42 115.2 48.3 less-open 158.9 104.4 60.3 less-open 159.11 95.3 75.4 less-open 160.01 99.7 77.5 less-open 160.54 305.9 42.2 less-open 160.83 93.4 77.3 less-open 162.32 312.4 46.4 less-open 162.55 4.4 26.0 less-open 163.17 118.2 49.93 less-open 163.43 115.25 61.31 less-open 163.81 310.1 48.5 less-open 163.92 105.7 58.3 less-open 164.64 323.3 74.6 less-open 165.75 3.0 45.2 less-open 166.1 131.9 48.6 less-open 166.44 150.5 46.7 less-open 166.79 230.8 30.3 less-open 166.87 240.9 30.3 less-open 167.59 141.5 25.5 less-open 167.96 168.2 29.5 less-open 168.6 164.2 33.4 less-open 169.15 147.4 37.3 less-open 169.76 137.2 36.0 less-open 170.01 140.3 46.1 less-open Page5 Sof 7

Fracture Orientations Interpreted from MW-60 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw6Oi.xls depth (feet) 170.5 171.33 172.15 172.77 173.92 174.02 174.25 174.31 174.67 174.92 175.11 175.79 176.98 177.26 177.75 178.07 O178.31 179.73 180.35 180.85 182.89 184.41 186.09 186.31 187.15 187.83 188.27 189.48 189.98 190.74 190.91 191.56 192.04 192.27 192.91 193.4 193.65 193.71 193.9 194.13 194.41

.195.27 195.54 197.4 down-dip compass azimuth (degrees) 179.7 165.6 135.5 340.7 123.0 160.0 7.8 100.4 135.3 128.2 151.7 179.4 193.5 127.4 121.6 108.3 111.9 336.4 123.4 263.5 268.7 123.3 219.5 264.8 317.3 276.3 114.2 344.8 109.2 139.3 109.0 132.5 110.6 351.37 116.9 1'14.9 140.1 165.7 129.4 129.4 139.4 101.0 93.2 122.53 dip angle (degrees) 38.7 35.5 42.0 32.7 34.3 40.8 53.2 35.5 44.5 41.4 34.5 51.3 40.0 47.1 44.9 50.0 45.7 54.6 54.8 66.5 78.7 63.0 33.0 67.7 66.3 64.5 60.8 54.3 55.9 31.4 57.6 47.1 53.71 75.1 52.3 39.3 38.6 32.6 40.5 53.2 42.9 62.9 71.9 46.45 interpreted planar feature category less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 6.1.of 7.

Fracture Orientations Interpreted from MW-60 AcousticTeleviewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw60i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 198.21 230.33 27.44 less-open 199.28 162.06 53.05 less-open 200.14 116.4 89.22 less-open 200.31 152.88 89.64 less-open 200.52 233.74 88.98 less-open 200.95 121.87 89.1 less-open 0

Page :7 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw62i.xls depth (feet) 43.33 43.47 44.24 44.28 44.46 44.56 44.77 44.82 45.40 45.80 46.10 46.48 46.77 47.01 47.38 47.65 47.97 47.98 48.31 48.89 49.14 49.83 50.44 50.63 51.40 51.67 52.71 52.95 53.32 53.44 53.82 53.89 54.26 54.71 54.97 55.12 55.35 55.84 56.20 56.73 57.74 O 58.29 58.70 58.70 down-dip compass azimuth (degrees) 35.9 95.5 351.6 99.9 327.2 347.2 346.3 105.2 315.6 98.5 100.7 105.9 331.1 92.8 331.4 292.9 117.7 102.3 109.2 337.6 98.5 111.8 90.0 99.3 94.9 100.1 11.7 99.0 306.1 203.3 300.6 107.9 206.8 207.4 213.7 204.9 207.2 300.8 309.6 198.6 74.2 85.2 66.5 108.1 dip angle (degrees) 38.3 68.3 50.0 71.1 50.8 32.2 33.4 74.2 44.6 63.9 67.0 64.3 31.5 51.8 49.6 33.8 73.2 73.0 68.9 21.2 64.8 70.0 69.5 74.3 77.7 72.2 24.5 72.4 38.7 72.9 35.3 68.9 69.2 65.3 67.6 63.8 71.4 44.9 43.1 73.3 12.2 68.2 75.5 67.7 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

Page 1 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 59.43 312.0 49.1 less-open 60.12 104.9 66.7 less-open 60.33 197.2 81.0 less-open 60.43 291.01 65.26 less-open 61.73

.5.58 24.04 less-open 62.36 306.8 31.7 less-open 62.73 99.58 67.95 less-open 63 300.07 64.71 less-open 63.61 208.7 60.1 less-open 63.84 111.3 63.5 less-open 64.65 100.0 65.8 less-open 64.78 213.5 59.6 less-open 64.94 303.2 46.6 less-open 65.35 108.3 70.5 less-open 65.89 111.7 67.7 less-open 66.36 112.5 63.7 less-open 66.56 122.2 64.8 less-open 66.92 110.3 62.7 less-open 67.54 109.0 49.7 less-open 67.86 104.0 67.8 less-open 68.16 283.7 42.9 less-open 68.29 99.0 74.7 less-open 68.38 93.3 58.3 less-open 68.82 97.4 64.8 less-open 69.19 215.7 67.2 less-open 69.83 220.4 71.7 less-open 70.09 116.0 61.7 less-open 71.06 114.9 60.0 less-open 71.45 130.4 61.9 less-open 72.05 107.2 67.4 less-open 72.09 209.1 58.5 less-open 72.22 100.4 70.3 less-open 72.64 295.4 36.4 less-open 72.72 90.5 67.1 less-open 73.46 119.2 65.5 less-open 73.85 346.1 45.7 less-open 74.13 108.9 65.4 less-open 74.29 344.76 45.71 less-open 74.55 306.53 60.33 less-open 74.93 351.2 49.7 less-open 75.12 107.5 62.8 less-open 75.38 117.5 67.4 less-open 75.64 107.7 67.5 less-open 75.89 352.2 48.6 less-open Page'2 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log IndianPoint Site O

Buchanan, NY Prepared for: GZA 105836 - mw62i.xls depth (feet) 76.02 76.46 76.82 77.33 78.19 78.56 79.56 81.07 81.48 81.60 81.67 82.28 82.53 82.88 82.95 82.99 O 83.02 83.26 84.02 84.4 84.81 85.95 86.49 86.68 87.44 87.83 88.01 88.66 88.8 89.82 89.98 90.35 90.72 90.84 91.04 91.09 91.75 92.53 92.68 93 93.47 93.59 93.7 94.19 down-dip compass azimuth (degrees) 355.5 112.2 357.3 300.6 2.9 127.1 110.2 262.3 318.5 347.7 306.4 332.0 1.1 337.7 355.3 94.5 304.8 122.0 305.3 279.7 108.4 34.3 349.5 104.4 112.1 67.7 102.5 112.3 286.2 325.0 289.4 338.8 331.3 1.6 108.4 296.1 354.8 325.1 320.4 356.7 330.48 357.1 303.6 327.0 dip angle (degrees) 52.1 70.7 36.6 26.5 55.3 63.0 64.1 69.5 54.3 54.7 38.3 28.2 23.5 35.1 45.5 69.6 45.7 72.0 38.2 61.5 66.6 32.8 48.7 69.1 67.8 68.3 67.7 68.7 48.2 47.7 54.1 30.9 56.5 52.8 65.0 50.4 56.1 52.1 48.3 53.62 64.81 54.3 53.9 43.8 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page -3 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 94.46 322.0 43.5 less-open 94.65 319.2 46.9 less-open 95.09 321.0 48.9 less-open 95.91 328.5 47.8 less-open 97.76 278.0 47.8 less-open 99.14 105.1 61.9 less-open 99.17 308.41 44.25 less-open 99.61 304.96 62.27 less-open 100.51 311.6 41.5 less-open 100.78 356.9 55.7 less-open 100.97 344.5 25.3 less-open 103.47 115.5 63.8 less-open 103.57 114.8 61.6 less-open 103.72 316.3 39.8 less-open 104.45 87.5 63.1 less-open 105.87 303.7 60.8 less-open 106.43 113.8 59.2 less-open 106.86 282.5 56.1 less-open 107.54 29.6 53.5 less-open 108.05 29.6 56.8 less-open 108.86 252.0 50.2 less-open 109.21 302.7 45.9 less-open 110.54 307.5 36.3 less-open 110.77 310.9 41.7 less-open 111.1 110.5 62.8 less-open 111.23 293.4 36.0 less-open 111.82 107.8 66.2 less-open 113.15 314.8 38.1 less-open 113.3 305.8 39.9 less-open 114.7 312.2 37.3 less-open 115.95 1.0 43.1 less-open 116.56 359.6 52.3 less-open 116.74 111.4 66.2 less-open 117.49 336.6 50.4 less-open 117.73 316.9 47.8 less-open 117.99 50.0 44.5 less-open 118.14 111.4 66.2 less-open 118.98 96.6 64.1 less-open 119.33 302.6 43.2 less-open 119.88 115.9 60.9 less-open 120.41 295.8 49.9 less-open 120.65 108.5 63.8 less-open 120.66 329.1 32.6 less-open 120.98 101.6 66.2 less-open Page '4, of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls depth (feet) 120.99 121.36 121.64 122.18 122.6 122.89 123.41 123.8 123.86 124.75 124.92 128.82 129.8 130.28 130.56 130.85 131

.132.23 132.57 132.85 133.13 134.06 134.32 134.65 135.19 135.39 135.64 135.84 136.54 137.03 138.54 139.01 139.21 139.63 140.52 140.76 143.61 144.4 144.91 145.54 148.71 O149.95 150.24 150.7 down-dip compass azimuth (degrees) 2.9 315.0 309.9 296.2 340.8 294.8 324.7 311.7 127.1 295.9 52.2 61.4 351.1 281.2 121.5 115.6 281.5 101.4 109.0 119.5 92.3 119.4 118.5 106.2 114.44 125.78 114.8 108.8 105.2 299.8 315.7 100.4 92.9 116.7 325.6 104.7 332.3 328.6 110.5 340.0 105.1 332.8 101.7 190.2 dip angle (degrees) 37.6 46.6 43.0 38.7 48.8 67.7 57.0 75.7 58.9 60.3 60.8 67.8 69.6 33.4 59.9 56.4 37.7 67.3 64.0 62.0 67.5 63.1 62.1 58.5 64.63 61.15 62.9 66.4 63.6 62.2 69.8 69.4 71.0 63.0 50.5 71.8 10.6 55.8 63.9 33.4 70.2 64.3 68.8 27.0 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page ý5 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Teieviewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 150.74 207.1 69.6 less-open 151.03 83.0 70.5 less-open 151.24 83.0 66.2 less-open 152.27 339.3 57.7 less-open 152.42 336.7 58.9 less-open 153.24 240.4 24.2 less-open 153.31 254.0 34.0 less-open 153.75 340.8 50.7 less-open 153.89 339.0 55.8 less-open 155.3 343.2 54.0 less-open 156.87 328.7 47.9 less-open 158.23 333.8 33.5 less-open 158.38 332.6 46.9 less-open 159.03 322.2 54.7 less-open 159.32 321.8 39.5 open 159.7 332.4 48.9 less-open 159.78 325.5 47.2 less-open 160.5 332.1 47.0 less-open 160.51 115.5 60.8 less-open 160.8 105.3 63.8 less-open 161.15 320.5 45.4 less-open 161.56 315.0 48.7 less-open 161.69 325.6 45.3 less-open 161.93 320.6 49.5 less-open 162.2 324.0 45.8 less-open 162.37 322.0 44.7 less-open 163.38 84.0 46.1 less-open 163.87 25.8 21.2 less-open 164.07 101.5 70.2 less-open 164.41 98.79 72.05 less-open 165.42 359.5 47.5 less-open 165.44 285.4 34.9 less-open 166.03 342.8 47.4 less-open 168.12 6.2 49.2 less-open 168.67 31.4 16.3 less-open 169.28 28.3 58.3 less-open 169.37 332.8 50.6 less-open 169.67 43.7 42.9 less-open 170.28 44.1 67.9 less-open 170.37 57.11 35.34 less-open 170.77 34.39 27.47 less-open 171.24 65.69 35.01 less-open 171.73 341.53 57.13 less-open 172.57 335.41 56.48 less-open Pag'e;6 of 7

Fracture Orientations Interpreted from MW-62 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw62i.xls depth (feet) 173.46 173.99 174.16 174.49 174.83 175.71 175.84 179.07 179.24 179.92 181.48 182.32 184.03 184.23 184.42 185.34 185.79 186.81 188.54 188.89 189.81 190.68 190.91 193.29 193.65 195.42 195.91 196.37 196.49 196.68 196.71 197.12 197.2 197.32 197.34 197.67 198.24 198.71 199.02 down-dip compass azimuth (degrees) 10.43 323.84 338.07 335.32 311.21 332.86 92.52 95.76 97.17 329.87 249.48 12.37 151.01 322.28 307.68 249.46 349.03 76.35 303.13 317.52 298 31.9 346.94 296.54 294.57 301.71 332.07 333.48 98.98 130.8 128.03 57.65 45.38 127.06 129.94 113.41 13.18 19.77 11.6 dip angle (degrees) 53.91 58.9 51.91 49.31 59.01 65.51 71.41 67.85 70.62 71.17 62.23 42.33 68.38 71.21 45.33 58.86 30.78 45.93 39.12 47.22 73.28 14.42 22.29 77.33 42.41 16.23 16.06 49.34 72.33 76.02 52.57 41.03 37.82 65.5 68.23 69.54 32.18 87.87 87.35 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page T7of 7

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls 0

depth (feet) 36.98 37.28 37.41 37.44 37.46 37.49 38.08 38.33 39.01 39.69 40.12 40.53 40.90 41.22 41.31 41.47 41.76 42.53 42.80 42.89 43.10 43.17 43.31 43.78 44.27 44.45 44.57 45.14 45.20 45.59 45.69 45.75 45.78 45.78 45.98 46.30 46.55 46.59 46.68 46.87 47.12 47.48 48.32 48.34 down-dip compass azimuth (degrees) 87.0 84.2 282.4 87.1 64.5 257.0 79.2 266.2 143.8 147.1 283.5 193.5 275.8 275.0 248.9 236.3 213.0 287.8 280.5 308.5 83.9 241.5 100.1 90.3 89.3 269.4 109.5 316.0 7.2 83.1 277.9 280.4 96.6 97.5 103.2 89.5 305.9 81.6 98.0 89.9 278.9 267.9 259.9 108.6 dip angle (degrees) 56.2 48.8 39.6 49.4 57.1 42.6 57.1 26.9 76.0 75.5 24.5 42.5 26.0 20.6 67.4 49.5 55.1 14.3 14.9 16.3 53.7 64.5 41.9 43.7 60.1 63.8 79.6 58.4 22.6 57.7 41.6 38.5 39.4 57.6 50.0 55.2 33.1 50.0 57.4 69.2 39.0 43.1 46.4 63.5 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open l~ess-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

0 Page 1 of -11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw63i.xls depth (feet) 48.43 48.72 48.95 49.01 49.41 49.95 50.33 50.51 50.55 50.74 50.97 51.04 51.17 51.25 51.56 51.93 52.11 52.27 52.43 52.62 52.69 52.81 52.92 53.56 53.59 53.70 53.77 54.09 54.16 54.50 54.70 54.79 54.91 55.11 55.51 55.67 55.73 56.01 56.38 56.39 56.64 57.19 57.25 57.36 down-dip cornpass azimuth (degrees) 191.9 269.04 290 94.3 311.47 289.66 279.3 90.4 306.5 320.4 87.5 96.8 253.2 85.6 149.4 316.1 307.0 325.6 319.0 301.9 102.4 102.6 265.4 102.4 300.7 53.8 112.5 312.1 102.7 251.0 310.0 299.1 295.6 80.7 105.3 299.14 107.05 290.6 301.6 89.1 308.3 97.2 307.9 307.6 dip angle (degrees) 48.2 42.11 42.87 61.2 31.1 35.66 44.4 57.5 38.2 34.2 54.3 52.0 62.6 35.1 78.6 42.7 32.6 39.8 47.3 36.7 42.1 44.9 51.3 66.7 41.9 51.9 41.7 42.1 38.5 55.1 46.7 44.7 49.2 42.5 39.9 41.72 44.95 46.6 47.2 40.8 62.0 47.6 53.1 56.4 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 2'of 1.1

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 57.49 316.1 52.0 less-open 57.61 314.9 52.9 less-open 57.80 315.0 47.8 less-open 57.96 307.0 48.2 less-open 58.41 144.9 64.2 less-open 58.49 272.6 33.4 less-open 58.58 101.0 52.4 less-open 58.76 91.8 46.7 less-open 58.95 301.0 47.2 less-open 59.22 79.0 32.5 less-open 59.48 97.2 42.9 less-open 59.92 94.4 36.3 less-open 60.26 295.0 40.2 less-open 60.37 78.0 54.2 less-open 60.43 305.6 36.9 less-open 60.49 102.7 52.6 less-open 60.72 325.0 68.6 less-open 60.95 114.8 46.4 less-open 61.39 109.4 53.0 less-open 61.54 319.3 75.4 less-open 62.55 127.4 46.2 less-open 62.98 123.1 72.5 less-open 63.26 295.3 44.6 less-open 63.59 258.3 31.2 less-open 63.82 103.5 59.2 less-open 64.23 264.9 36.5 less-open 64.33 98.2 65.0 less-open 64.42 92.8 64.4 less-open 64.84 91.8 55.1 less-open 64.89 127.6 23.1 less-open 65 98.3 55.7 less-open 65.14 91.9 44.7 less-open 65.6 95.8 41.8 less-open 65.92 86.3 52.4 less-open 66.05 89.0 57.4 less-open 66.19 95.9 44.7 less-open 66.2 250.9 62.7 less-open 66.22 297.83 80.36 less-open 66.3 99.31 42.17 less-open 66.5 323.7 23.9 less-open 66.66 324.1 40.3 less-open 66.83 308.7 29.0 less-open 66.99 83.0 43.5 less-open 67.12 91.3 58.4 less-open Page 3 ofl11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site O

Buchanan, NY Prepared for: GZA 105836 - mw63i.xls depth (feet) 67.21 67.28 67.52 67.74 67.88 68.18 68.53 68.55 68.67 68.97 69.27 69.42 69.72 69.95 70.03 70.4 70.95 70.97 71.99 72.15 72.32 72.65 72.67 72.92 73.31 73.32 73.53 73.79 74.28 74.37 74.6 75.33 75.36 75.46 75.57 75.79 76.21 76.33 76.96 77.13 77.65 O 77.88 78.05 78.07 down-dip compass azimuth (degrees) 86.6 290.1 329.3 79.7 90.74 260.41 292.4 306.6 82.1 294.4 335.9 111.0 101.5 281.3 97.0 90.4 102.0 290.9 99.7 341.3 88.9 101.9 269.8 94.6 104.7 323.8 66.1 92.5 107.1 10.0.8 314.1 97.0 211.1 110.9 122.7 100.7 101.3 105.6 95.9 90.5 100.3 79.2 319.7 104.6 dip angle (degrees) 42.6 48.9 51.2 43.2 30.17 33.48 70.1 47.8 29.7 67.6 31.2 24.3 45.9 28.0 30.2 59.0 50.4 32.5 49.8 81.2 54.5 51.8 31.1 39.3 53.3 44.1 51.0 41.0 51.3 47.3 68.0 41.8 63.0 39.9 38.2 51.2 44.8 45.6 47.4 60.4 45.5 51.1 63.4 50.7 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open PagEk 4 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 78.58 245.5 32.7 less-open 78.69 256.2 32.1 less-open 78.79 244.7 33.6 less-open 78.95 249.8 37.1 less-open 79.4 231.6 49.1 less-open 79.44 309.4 49.0 less-open 79.54 101.2 55.0 less-open 79.89 218.7 63.0 less-open 80.26 128.0 50.4 less-open 80.52 99.1 52.9 less-open 80.58 335.5 72.1 less-open 80.75 194.3 36.4 less-open 81.68 333.1 78.0 less-open 83.34 160.9 36.1 less-open 84.36 148.0 44.6 less-open 84.37 307.4 70.5 less-open 84.46 331.5 63.6 less-open 84.95 94.5 44.7 less-open 85.13 158.3 15.7 less-open 85.31 201.6 36.5 less-open 85.45 315.6 19.8 less-open 85.69 213.3 9.6 less-open 86.14 150.27 78.24 less-open 86.31 261.63 34.99 less-open 86.98 89.5 62.9 less-open 87.16 265.1 47.0 open 87.19 95.7 56.7 less-open 87.64 159.2 80.2 open 87.85 312.1 35.8 less-open 88.37 164.5 74.7 open 89.71 139.9 73.7 open 89.86 166.0 73.1 open 90.21 162.5 34.9 less-open 90.56 169.1 58.2 less-open 90.67 155.4 45.2 less-open 91.76 339.7 80.2 less-open 91.76 135.4 65.9 open 92.43 147.6 66.0 open 92.49 344.8 60.5 open 92.88 130.2 61.4

open, 93.11 178.9 62.4 open 93.72 167.6 70.2 less-open 94.16 164.5 69.1 less-open 94.84 139.7 51.5 open Page'5 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw63i.xls depth (feet) 95 95.17 95.45 96.8 97.09 97.49 97.71 98.09 98.31 98.51 98.53 98.7 99.03 99.19 99.4 99.65 O 99.83 100.14 100.31 100.84 100.93 101.62 101.8 102.05 102.34 102.95 103.65 103.7 104.08 104.64 104.73 105.1 105.45 106.07 107.43 108.01 110.53 110.61 110.67 112.57 113.73

.113.74 114.13 114.32 down-dip compass azimuth (degrees) 289.52 153.6 151.6 124.73 1.7 315.0 300.8 306.7 291.1 331.4 286.5 246.0 241.6 161.9 248.4 305.6 269.7 255.2 97.0 260.5 155.3 323.7 316.2 312.0 274.9 195.1 154.2 261.8 109.93 253.58 243.4 68.3 98.3 311.6 306.0 278.8 319.0 320.0 320.0 263.36 344.04 252.12 350.58 137.01 dip angle (degrees) 81.78 70.0 67.8 82.15 43.5 43.7 50.0 40.0 33.8 79.6 33.8 48.0 28.7 75.8 49.3 31.7 25.6 36.7 41.7 28.9 64.5 77.3 44.8 46.9 28.5 51.1 60.3 34.8 49.01 31.29 36.9 69.1 54.4 46.5 43.6 36.6 51.6 44.9 52.4 33.15 58.34 31.8 31.52 64.52 interpreted planar feature category open less-open less-open open open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page.6 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 114.53 274.06 27.43 less-open 115.43 253.24 30.36 less-open 115.87 95.72 62.81 less-open 116.6 139.87 65.13 less-open 117.6 146.1 61.22 less-open 117.85 160.56 61.64 less-open 117.87 258.22 31.98 less-open 118.6 216.1 43.4 less-open 119.11 288.79 31.64 less-open 119.37 121.55 59.66 less-open 119.84 314.73 33.02 less-open 120.11 97.44 72.18 less-open 120.27 311.77 36.3 less-open 120.71 316.07 36.53 less-open 120.99 314.29 28.93 less-open 121.06

-114.79 58.17 less-open 121.37 325.61 37.73 less-open 121.59 137.4 65.71 less-open 121.83 292.8 55.32 less-open 122.97 316.23 64.58 less-open 124.04 326.69 37.69 open 124.44 104.86 65.55 less-open 124.75 298.26 48.02 less-open 124.99 103.52 62.67 less-open 125.24 120.19 60.36 less-open 125.45 121.65 60.88 less-open 125.58 103.59 61.89 less-open 125.71 114.58 65.9 less-open 126 127.51 53.02 less-open 126.38 113.83 60.37 less-open 126.62 122.56 56.86 less-open 126.73 117.71 55.11 less-open 126.89 122.66 65.44 less-open 127.06 94.3 49.84 less-open 127.44 121.63 54.99 less-open 127.49 339.35 81.93 less-open 127.69 139.26 61.23 less-open 127.88 134.59 53.84 less-open 128.15 137.43 56.86 less-open 128.55 135.86 60.24 less-open 129.15 107.96 55.03 less-open 129.73 112.9

.54.93 less-open 130.1 116.18 47.05 less-open 130.27 282.59 65.52 less-open Page 7 of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: OZA 105836 - mw63i.xls depth (feet) 130.51 131.23 131.66 133.15 133.36 133.38 133.91 134.06 134.3 134.37 134.45 134.82 136.59 136.77 137.48 137.51 O 137.98 138.02 138.11 138.2 138.37 139.52 139.96 140.22 140.73 140.76 142.05 142.92 143.3 143.73 144.08 144.36 144.94 146.06 146.07 146.92 147.26 147.83 148.14 148.47 148.77 O 149.09 149.22 149.64 down-dip compass azimuth (degrees) 116.82 300.7 119.68 106.33 102.79 103.52 105.11 109.88 112.33 346.22 110.86 103.53 293.56 107.88 117.24 214.7 114.83 338.68 329.41 116.27 117.06 127.22 105.12 255.56 277.76 274.08 282.23 350.42 316.45 81.93 119.88 106.92 260.66 255.39 124.13 115.71 319.9 124.7 112.31 330.59 116.25 114.78 106.13 116.23 dip angle (degrees) 56.56 59.97 58.83 58.99 74.86 59.27 61.26 60.85 57.91 82.76 58.15 54.67 35.63 59.84 59.87 35.92 59.32 41.3 49.84 54.34 57.88 48.78 61.48 39.02 12.19 15.38 20.24 30.4 30.54 39.87 60.02 50.78 37.76 42.3 65.09 60.8 51.04 54.58 60.59 65.8 58.39 60.42 65.22 59.94 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 8,of 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 150.34 106.99 59.72 less-open 151.25 109.84 59.43 less-open 151.37 112.33 57.71 less-open 151.64 122.62 58.33 less-open 151.91 111.62 39.26 less-open 152.17 98.68 60.91 less-open 153.02 334.34 52.01 less-open 153.16 117.27 61.38 less-open 153.47 121.62 63.63 less-open 153.66 118.75 64.78 less-open 154.4 130.48 60.1 less-open 154.4 353.57 43.1 less-open 154.62 127.18 57.43 less-open 154.76 104.09 67.8 less-open 154.85 124.56 65.62 less-open 155.01 103.18 53.16 less-open 155.09 343.8 50.71 less-open 155.2 116.29 57.05 less-open 156.03 350.76 43.44 less-open 156.69 348.73 47.92 less-open 156.85 337.43 40.13 less-open 157.09 351.56 53.05 less-open 157.62 342.85 53.98 less-open 158.24 131.99 58.32 less-open 159.36 294.35 28.72 less-open 159.67 131.91 58.9 less-open 160.18 124.08 57.21 less-open 160.22 342.65 52.51 less-open 161.54 128.07 54.83 less-open 161.7 124.38 56.83 less-open 161.93 142.26 43.55 less-open 162.15 107.97 66.86 less-open 162.68 350.1 47.24 less-open 162.69 124.02 65.53 less-open 162.94 325.41 61.76 less-open 163.26 342.33 43.27 less-open 163.49 351.46 54.91 less-open 163.86 332.9 40.56

  • less-open 163.98 305.8 44.52 less-open 164.13 140.85 58.56 less-open 164.37 342.46 39.91 less-open 164.6 122.62 53.51 less-open 164.95 139.88 49.65 less-open 165.21 131.9 48.54 less-open Page 9 of 1-1

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site O

Buchanan, NY Pre pared for: GZA 105836 - mw63i.xls depth (feet) 165.45 166.06 166.6 166.98 168.52 168.82 168.92 169.65 170.45 170.84 171.09 171.39 171.76 171.98 172.56 173.05 173.74 O 174.05 174.76 175.57 175.65 175.77 175.94 177.35 177.47 177.81 178.29 179.02 179.24 180.05 181.5 181.94 182.03 182.65 182.87 182.98 183.9 184.13 184.15 185.77 186.13 O 186.35 186.96 187.67 down-dip compass azimuth (degrees) 144.99 82.48 69.69 108.49 136.96 237.18 133.44 279.07 107.96 92.7 128.76 108.42 287.77 263.41 295.17 351.76 112.22 129.07 26.99 24.15 278.15 314.81 346.81 9.14 319.98 349.83 319.35 106.98 99.37 243.82 317.12 50.37 245.15 94.26 260.05 356.15 343.91 260.33 347.41 318.7 73.7 226.61 118.81 100.64 dip angle (degrees) 53.61 51.05 55.95 68.11 64.22 33.63 70.67 27.48 63.68 61.18 54.02 60.73 60.83 23.64 28.02 34.68 69.34 57.49 38.98 39.51 60.07 61.53 51.68 33.44 31.74 62.33 62.48 60.95 61.16 32.39 15.72 45.09 34.86 67.91 43.53 75.44 65.59 76.33 68.25 40.4 41.56 44.51 58.6 66.57 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 110 of, 11

Fracture Orientations Interpreted from MW-63 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw63i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 188.52 109.8 64.59 less-open 189.02 114.26 53.4 less-open 189.31 69.75 34.35 less-open 189.7 56.5 34.53 less-open 190.61 342.45 78.68 less-open 191.63 349.37 89.46 less-open 0

Page 11 'of 11

Fracture Orientations Interpreted from MW-65 Acoustic Televiewer Log Indian Point Site O

Buchanan, NY Prepared for: GZA 105836 - mw65i.xls depth (feet) 38.18 38.34 38.86 38.99 40.82 41.03 42.35 42.51 42.70 42.90 43.19 43.47 43.73 44.15 44.65 45.01

.45.10 45.34 45.58 46.63 46.90 47.13 47.61 48.46 51.70 52.01 52.15 52.34 53.61 55.55 56.32 56.64 58.01 59.26 60.32 61.57 64.21 65.18 66.22 66.66 68.54 O69.51 70.58 70.89 down-dip compass azimuth (degrees) 236.7 145.7 147.3 331.5 351.6 354.4 297.4 139.7 137.8 124.3 163.5 290.7 145.0 130.4 125.7 152.0 130.0 177.3 144.5 132.8 145.7 159.5 175.0 132.6 133.0 146.9 186.6 350.6 132.0 126.7 310.0 137.1 101.9 75.2 232.8 248.0 286.3 190.3 293.0 80.0 181.9 90.1 68.0 82.0 dip angle (degrees) 20.7 46.5 59.9 83.1 70.3 66.8 80.3 46.7 32.0 36.2 27.3 69.0 46.6 43.3 32.2 44.4 21.2 82.5 46.7 42.0 38.5 50.4 82.7 40.1 45.7 44.8 31.2 77.7 44.4 51.6 77.7 51.6 55.1 46.8 28.4 18.6 54.4 19.9 24.2 36.2 77.9 36.1 28.7 29.8 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

Page 1. of 2

Fracture Orientations Interpreted from MW-65 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw65i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 71.09 45.9 40.6 less-open 71.56 293.7 38.0 less-open 71.92 343.7 62.8 less-open 78.01 108.8 76.7 less-open 79.38 275.6 32.1 less-open 0

Page 2 of 2

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site O

Buchanan, NY Prepared for: GZA 105836 - mw66i.xls depth (feet) 38.15 38.35 39.06 39.83 40.18 40.40 40.52 41.46 41.79 41.81 41.98 42.17 43.15 43.27 43.75 44.00 44.19 44.82 44.86 45.88 46.24 46.27 46.59 46.97 47.38 47.44 47.68 47.96 48.39 48.54 49.07 49.67 49.78 50.32 50.61 51.15 51.34 52.95 53.58 53.68 54.66 54.99 56.72 57.44 down-dip compass azimuth (degrees) 354.8 336.5 308.3 332.3 281.5 180.8 328.2 309.0 197.6 167.1 314.6 280.7 4.9 184.9 189.6 191.1 185.5 213.2 202.1 149.2 321.8 232.6 291.5 131.7 159.3 153.5 338.6 325.2 177.9 21.4 185.1 146.4 190.7 345.5 341.1 134.4 132.2 121.8 110.6 225.2 345.6 287.8 324.2 96.3 dip angle (degrees) 22.8 28.3 13.5 30.0 19.9 63.0 16.2 41.9 77.0 76.5 32.6 29.9 23.3 75.5 61.9 66.1 66.4 69.9 36.7 31.4 56.2 32.9 42.1 37.5 32.7 29.9 38.4 55.0 81.5 78.2 32.3 19.0 42.5 33.6 24.7 76.5 48.6 57.4 47.7 70.3 28.8 34.2 52.4 76.7 interpreted planar feature category open open less-open open less-open less-open less-open less-open less-open less-open less-open less-open open less-open open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open open less-open open less-open less-open less-open less-open open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

Page 1 of 6

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log~

Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 58.45 86.7 82.3 less-open 59.46 91.1 83.0 less-open 59.75 244.8 74.1 less-open 61.20 316.6 29.3 less-open 61.56 288.9 24.5 less-open 63.81 209.5 53.9 less-open 64.52 118.5 45.1 less-open 65.84 128.2 50.1 less-open 66.17 98.8 28.4 less-open 66.20 259.5 70.3 less-open 66.39 134.4 37.8 less-open 69.24 191.0 56.9 less-open 70.05 116.98 45.29 less-open 71.3 271.1 82.12 less-open 72.28 85.1 28.4 less-open 73.02 269.9 77.3 less-open 74.39 346.8 29.7 less-open 74.85 178.1 74.2 less-open 75.92 189.6 82.3 less-open 81.78 124.0 39.9 less-open 82.61 356.2 80.1 less-open 84.24 193.9 41.2 less-open 85.01 177.4 79.2 less-open 85.30 178.0 80.9 less-open 86.06 186.1 55.1 less-open 86.61 192.8 57.9 less-open 87.23 174.3 67.5 less-open 87.92 189.1 65.9 less-open 88.08 176.6 72.9 less-open 88.59 189.9 79.5 less-open 89.39 157.2 77.5 less-open 89.59 165.4 82.0 less-open 90.41 170.5 77.0 less-open 90.69 152.1 71.0 less-open 90.97 168.4 76.7 less-open 92.04 163.5 84.6 less-open 93.29 169.6 81.9 less-open 94.19 169.6 83.6 less-open 94.86 162.7 26.5 less-open 95.13 160.7 42.0 less-open 96.44 179.8 79.1 less-open 96.45 51.6 16.1 less-open 100.43 292.4 59.7 less-open 100.92 179.91 78.76 less-open Page"2 of 6

Fracture Orientations Interpreted from MW-66 Acoustic.Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls depth (feet) 101.1 101.87 101.92 103.15 103.49 104.35 108.02 108.03 109.47 110.60 111.91 112.63 112.76 112.80 113.18 113.89 114.01 114.77 115.82 116.06 116.66 117.61 117.88 118.17 119.53 120.57 121.42 122.12 122.97 123.23 126.72 127.43 127.94 128.25 129.69 130.05 130.16 130.62 130.97 131.21 131.38 131.84 131.88 132.13 down-dip compass azimuth (degrees) 111.7 322.5 174.9 130.6 127.9 337.9 178.9 5.0 189.2 29.7 214.8 348.9 351.9 73.1 170.8 191.5 188.5 172.1 182.8 183.8 180.3 305.0 336.1 216.6 232.5 353.8 334.0 189.7 208.5 354.9 355.7 350.5 343.9 338.6 341.0 333.5 205.0 279.6 213.0 282.1 203.5 204.2 351.7 210.0 dip angle (degrees) 55.83 63.2 76.3 42.7 51.0 35.9 78.9 38.8 42.4 70.5 54.0 65.7 62.2 47.3 77.8 72.2 75.5 86.0 75.5 75.7 78.7 31.3 38.3 50.1 61.9 56.5 58.6 40.4 51.6 58.1 36.0 51.2 40.5 39.6 55.6 60.8 53.1 46.0 38.7 43.0 46.4 51.8 75.8 53.2 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page.,3 of 6

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 132.66 341.5 45.3 less-open 132.69 15.59 76.88 less-open 132.77 325.59 42.93 less-open 132.88 329.9 42.2 less-open 133.42 338.9 29.2 less-open 133.81 311.5 58.5 less-open 133.85 10.0 59.8 less-open 134.61 94.9 74.5 less-open 134.76 205.9 36.9 less-open 135.04 302.0 37.3 less-open 135.47 334.0 51.8 less-open 135.71 326.7 41.4 less-open 135.87 286.93 44.93 less-open 135.88 157.81 54.39 less-open 136.39 327.9 51.9 less-open 136.64 313.0 34.9 less-open 136.82 301.1 44.4 less-open 137.43 296.8 40.8 less-open 137.5 291.8 36.0 less-open 137.55 257.6 20.7 less-open 137.68 171.1 63.8 less-open 137.79 296.7 37.3 less-open 138.22 325.4 48.7 less-open 138.45 337.4 52.3 less-open 138.71 185.1 31.5 less-open 138.98 200.0 45.3 less-open 139.16 213.2 41.8 less-open 139.36 167.4 43.8 less-open 139.86 308.2 67.9 less-open 139.96 205.0 56.6 less-open 140.9 312.3 72.7 less-open 141.11 336.7 23.1 less-open 141.74 303.2 36.2 less-open 141.86 109.2 55.4 less-open 141.88 283.6 39.8 less-open 142.72 124.3 58.4 less-open 143.02 320.6 61.8 less-open 143.5 240.7 59.4 less-open 143.56 303.9 75.5 less-open 143.58 316.2 56.3 less-open 144.04 115.3 55.9 less-open 144.76 114.2 62.8 less-open 144.85 297.7 44.0 less-open 145.44 310.9 53.7 less-open Page 4 of 6

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site O

Buchanan, NY Prepared for: GZA 105836 - mw66i.xls depth (feet) 145.44 146.66 146.93 147.24 148.77 148.99 149.16 149.3 150.56 150.78 151.33 152.83 154.53 155.03 155.39 155.81 156.19 156.45 157.03 157.16 157.75 158.47 158.7 159.02 159.95 159.95 160.58 161.16 161.73 163.11 163.45 163.89 164.15 164.26 164.37 164.61 164.67 165.88 166.51 166.53 167.67 O 167.79 167.81 168.7 down-dip compass azimuth (degrees) 123.2 336.8 328.9 158.9 109.2 102.0 107.5 101.9 123.2 102.6 230.5 143.0 115.0 109.2 106.6 112.0 299.6 332.2 120.1 321.8 355.6 144.1 349.9 329.3 343.6 109.2 213.3 288.4 299.8 104.2 107.98 353.09 104.5 108.0 108.8 349.9 347.8 316.6 168.5 322.0 327.1 313.4 202.2 230.2 dip angle (degrees) 48.6 54.8 48.6 42.2 71.4 56.1 57.2 51.8 61.4 51.0 70.3 38.0 57.1 63.4 65.8 62.6 24.6 30.3 55.8 34.9 54.1 55.2 57.6 41.8 50.2 44.1 50.4 36.4 29.9 43.9 40.85 41.88 68.5 58.1 60.0 54.0 47.1 44.0 81.1 42.7 36.9 42.2 71.1 71.6 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 5 of 6

Fracture Orientations Interpreted from MW-66 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw66i.xls down-dip interpreted compass.

dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 169.15 219.3 63.1 less-open 170.67 335.1 51.5 less-open 170.94 8.6 56.6 less-open 171.24 318.0 60.3 less-open 173.63 344.2 50.8 less-open 174.63 322.0 44.6 less-open 175.1 44.3 70.2 less-open 175.73 324.8 52.4 less-open 175.98 101.1 61.0 less-open 176.02 283.3 38.1 less-open 176.57 102.0 56.8 less-open 177.31 332.2 59.9 less-open 178.31 322.9 50.4 less-open 179.3 326.3 41.4 less-open 179.86 132.4 60.1 less-open 180.13 308.3 41.7 less-open 180.66 125.4 60.0 less-open 180.83 333.1 57.7 less-open 180.88 126.4 56.0 less-open 183 185.2 76.0 less-open 184.01 295.5 45.6 less-open 184.85 126.2 41.8 less-open 187.41 302.4 42.6 less-open 187.94 302.9 52.6 less-open 189.36 331.7 76.7 less-open 189.65 287.1 32.8 less-open 190.39 127.7 37.7 less-open 190.45 328.1 48.4 less-open 190.72 338.7 45.3 less-open 191.53 289.8 29.6 less-open 195.62 62.9 73.9 less-open 197.85 124.3 51.9 less-open 198.36 309.1 88.6 less-open 198.79 311.6 86.7 less-open Page 6'of 6

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY 40 Prepared for: GZA 105836 - mw67i.xls depth (feet) 32.54 33.17 33.71 33.80 34.14 34.32 34.76 34.77 35.05 35.09 35.15 35.29 35.74 37.07 37.13 37.13 37.59 37.60 38.06 38.27 38.75 39.27 40.58 41.15 41.29 41.52 41.59 41.74 41.75 42.03 42.31 42.43 42.57 42.57 42.66 43.12 43.58 43.72 43.89 44.33 44.38 44.60 44.90 45.77 down-dip compass azimuth (degrees) 251.1 346.9 309.7 297.4 188.2 189.6 272.8 82.1 19.9 171.0 282.2 192.5 292.3 319.2 284.4 291.7 68.8 274.1 137.9 255.9 257.1 206.6 309.6 167.4 204.8 161.3 316.2 171.9 212.8 207.9 245.0 139.8 240.9 319.9 225.3 275.1 231.6 165.5 179.7 245.3 150.3 231.7 281.3 134.8 dip angle (degrees) 60.4 72.1 72.5 53.4 71.4 72.9 51.7 73.7 19.8 62.3 47.2 70.5 27.8 68.9 46.7 29.6 44.4 50.6 51.0 54.9 33.2 45.7 43.7 23.4 71.4 41.0 39.9 65.0 75.7 72.5 52.8 69.4 45.8~

67.2 30.7 37.3 39.3 60.3 77.9 33.9 43.8 78.2 24.1 27.6 interpreted planar feature category less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

Page 1 of 13

Fracture Orientations Interpreted from MW-67 Acoustic televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 46.53 122.7 69.9 less-open 46.56 145.4 68.4 less-open 48.20 202.0 69.5 less-open 48.63 208.3 65.9 less-open 48.75 200.9 66.2 less-open 49.00 221.4 63.9 less-open 49.23 330.3 69.0 less-open 49.27 201.9 62.0 less-open 50.13 10.6 24.4 open 50.58 92.7 20.0 less-open 52.47 115.39 61.75 less-open 53.59 122.52 57.78 less-open 54.25 154.0 47.3 less-open 54.77 179.6 30.5 less-open 56.60 332.4 65.3 less-open 58.73 315.0 44.9 less-open 58.90 228.0 48.1 less-open 61.26 178.4 59.5 less-open 62.04 223.6 46.4 less-open 62.21 229.9 39.5 less-open 64.34 303.8 45.0 less-open 65.20 138.9 46.1 less-open 66.52 125.0 46.4 less-open 67.47 332.4 74.7 less-open 67.64 341.4 63.3 less-open 67.90 321.9 57.1 less-open 69.65 112.3 73.6 less-open 70.77 343.3 56.4 less-open 71.36 135.9 53.5 less-open 71.96 319.4 54.4 less-open 73.58 337.7 68.9 less-open 73.71 322.0 62.2 less-open 73.92 136.5 55.9 less-open 74.74 121.7 61.6 less-open 76.06 333.4 67.6 less-open 76.24 124.8 67.3 less-open 77.54 325.1 63.1 less-open 77.77 331.9 65.8 less-open 77.93 203.8 78.5 less-open 78.82 108.2 62.5 less-open 79.05 115.4 61.9 less-open 79.72 327.21 68.85 less-open 81.25 31.4 76.5 less-open 81.72 343.7 34.7 less-open Page62 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw67i.xls depth (feet) 82.67 83.25 84.12 84.73 85.10 85.17 85.39 86.26 87.30 88.14 88.17 89.61 91.21 93.22 94.34 94.67 95.82 97.07 97.72 97.86 98.1 99.51 99.54 100.58 101.27 101.78 102.46 102.47 102.85 103.38 103.47 103.75 104.23 104.59 104.68 105.26 105.27 106.01 106.13 106.46 O 106.69 107.03 107.18 down-dip compass azimuth (degrees) 341.4 116.0 122.8 106.7 100.7 121.3 186.2 322.6 185.1 327.9 130.5 329.2 335.4 259.6 238.6 221.6 211.4 108.0 93.7 179.2 193.0 342.6 39.1 182.4 5.2 8.2 228.3 196.0 345.6 201.5 117.7 131.3 350.9 164.8 215.5 347.3 352.8 344.2 323.1 244.3 119.5 183.5 334.9 124.36 dip angle (degrees) 75.7 69.4 67.8 73.9 24.6 71.5 78.0 57.4 71.1 69.2 73.0 58.5 63.3 49.8 66.4 71.8 74.9 78.0 62.2 79.8 79.1

.61.5 35.3 75.1 24.3 35.4 48.4 40.9 69.8 25.8 51.3 45.9 73.6 46.5 61.3 66.5 55.8 74.3 71.8 53.3 76.6 81.7 70.6 64.36 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open Page 3 of 13.

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 107.4 336.82 70.01 less-open 107.62 209.9 56.7 less-open 108.31 350.6 65.0 open 108.36 191.6 30.4 less-open 108.48 208.4 44.4 less-open 109 173.4 26.5 less-open 109.37 352.5 66.1 less-open 109.55 121.3 34.7 less-open 109.72 118.3 68.1 less-open 110.42 28.6 5.7 less-open 110.53 49.31 9.32 less-open 112.27 354.12 75.52 less-open 112.28 312.0 65.8 less-open 112.68 350.2 71.1 less-open 112.99 345.8 72.3 less-open 113.18 343.0 67.1 less-open 113.24 215.8 40.8 less-open 114.56 348.5 61.7 less-open 115.13 155.4 32.3 less-open 115.27 334.0 64.3 less-open 115.99 140.2 52.0 less-open 116.04 304.8 63.3 less-open 116.04 342.4 62.4 less-open 116.8 331.8 56.1 less-open 117.03 334.3 46.8 less-open 117.2 322.6 38.5 less-open 118.85 315.5 58.3 less-open 120.13 325.0 51.6 less-open 120.85 76.0 64.2 less-open 121.48 74.9 65.1 less-open 121.97 105.4 64.5 less-open 122.32 353.7 80.5 less-open 122.56 211.3 74.7 less-open 122.97 109.4 74.0 less-open 123.33 359.1 52.1 less-open 124.1 315.0 48.4 less-open 124.52 187.6 72.6 less-open 124.66 302.8 63.6 less-open 125.41 306.4 38.3 less-open 125.5 309.1 41.3 less-open 125.64 168.7 38.3 less-open 125.86 105.7 64.6 less-open 127.43 349.8 40.4 less-open 128.1 224.6 70.5 less-open Page 4 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: OZA 105836 - mw67i.xls depth (feet)

.130.01 130.59 130.71 130.83 131.18 131.76 133.27 134.59 135.11 135.36 136.09 136.51 136.6 136.83 137.64 137.85

.138.38 138.95 140.07 140.49 140.99 141.34 141.81 142.07 142.37 143.37 144.77 145.31 146.19 147.42 148.03 148.44 148.94 149.37 149.49 149.57 149.82 150.44 150.84 154.45 156.42

.156.77 157.68 158.63 down-dip compass azimuth (degrees) 341.1 178.3 316.6 177.1 167.6 182.6 173.7 16.9 176.5 346.1 183.1 176.0 333.7 191.7 185.2 184.4 244.4 240.5 169.7 203.9 197.0 204.2 10.2 113.5 2.8 356.8 344.6 340.5 336.8 135.33 134.6 116.6 133.5 108.1 320.3 141.1 126.1 306.0 186.8 340.5 191.3 175.9 188.0 dip angle (degrees) 31.3 69.5 37.1 71.2 75.9 69.5 71.0 37.1 75.4 35.5 74.4 74.4 47.3 70.3 69.8 68.3 66.6 57.3 70.7 13.8 48.1 45.2 63.8 49.1 80.3 80.7 52.0 48.9 74.42 51.39 51.9 54.8 46.8 44.7 40.9 48.1 57.0 49.1 47.4 42.8 35.2 54.7 73.1 53.7 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 5 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 158.92 346.9 72.0 less-open 159.12 226.3 38.8 less-open 159.52 210.9 58.1 less-open 159.79 268.3 26.6 less-open 159.92 253.8 27.5 less-open 160.54 123.3 56.8 less-open 160.83 109.0 58.7 less-open 160.83 181.5 77.7 less-open 160.83 292.0 29.0 less-open 160.97 193.5 67.0 less-open 161.46 199.2 54.1 less-open 161.73 198.1 64.2 less-open 161.82 218.8 57.8 less-open 161.99 129.5 68.0 less-open 162.3 109.2 57.9 less-open 163.27 171.6 77.0 less-open 163.87 338.6 26.7 less-open 164.42 172.0 24.1 less-open 165.78 169.0 30.8 less-open 166.02 283.5 60.5 less-open 166.38 3.1 56.2 less-open 166.47 179.7 49.2 less-open 167.12 225.4 52.6 less-open 167.9 171.0 57.9 less-open 168.36 233.4 45.9 less-open 168.86 9.3 35.6 less-open 170.74 347.1 75.4 less-open 171.11 291.1 26.1 less-open 173.3 311.9 69.7 less-open 173.37 99.3 68.7 less-open 174.02 291.8 68.5 less-open 174.84 288.8 69.9 less-open 175.07 1.78 46.13 less-open 175.4 96.71 66.18 less-open 175.8 97.8 64.9 less-open 176.32 286.0 79.0 less-open 176.37 104.9 48.6 less-open 176.71 99.0 51.6 less-open 176.75 297.4 55.8 less-open 177.1 299.5 82.6 less-open 178.98 130.4 26.6 less-open 179.14 204.5 24.2 less-open 179.62 129.1 59.6 less-open 180.05 110.45 64.54 less-open Page 6 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw67i.xls depth (feet) 180.14 180.98 181.27 181.47 182.81 183.4 184.36 184.66 186.3 187.1 187.45 188.04 188.4 188.51 188.78 190.61 190.63 190.83 191'.14 192.68 192.71 193 193.18 193.4 193.67 193.98 194.33 194.84 195.16 195.27 196.97 197.37 197.93 198.49 198.82 198.99 199.33 201.26 203.52 203.65 204.51 206.48 206.88 207.55 down-dip compass azimuth (degrees) 113.2 100.55 104.26 115.67 313.72 324.21 294.02 331.65 329.3 111.22 323 326.34 145.95 325.8 93.75 128.68 124.39 348.16 304.9 115.36 300.78 108.94 126.62 112.41 102.94 100.61 329.91 106.59 297.94 107.19 335.89 334.78 4.69 327.17 345.72 324.32 307.22 331.48 341.76 330.43 326.22 341.55 331.01 317.44 dip angle (degrees) 64.5 61.17 35.35 72.62 58.29 76.37 63.7 74.92 59.12 69.92 54.33 39.07 42.86 33.15 67.49 70.64 64.52 69.86 44.31 49.55 54.16 53.4

.62.27 66.14 66.99 61.3 64.28 64.38 67.89 60.91 41.99 51.7 65.65 66.62 58.97 55.1 56.71 43.72 66.03 67.69 42.42 60.23 55.49 29.34 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 7 ofl13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls s

depth (feet) 207.72 207.83 208.58 208.71 209.24 212.04 212.81 213.09 213.27 213.5 214 214.28 214.77 216.96 218 218.57 219.58 220.28 220.41 220.7 221.23 221.64 222.15 222.83 222.94 222.99 223.16 223.71 224.72 225.59 226.14 226.28 226.77 226.85 227.02 227.78 227.9 228.61 229.48 230.58 230.6 231.31 231.35 231.55 down-dip compass azimuth (degrees) 314.89 6.66 348.9 349.28 334.4 225.55 140.24 339.84 335.45 343.13 351.87 341.34 4.92 10.21 322.02 342.81 223.95 338.13 329.03 324.84 323,59 321.08 330.46 312.19 330.19 313.91 256.86 335.55 25.4 128.46 190.24 107.06 117.51 305.23 118.67 162.25 129.83 222.04 120.05 238.4 160.82 256.82 306.5 193.1 dip angle (degrees) 46.24 39.9 40.4 38.4 60.54 72.68 58.69 61.08 63.39 55.3 47.84 55.32 55.47 67.31 69.09 68.05 52.5 58.73 61.11 55.53 55.11 42.12 38.41 49.43 49.1 47.21 9.07 65.01 32.49 53.91 60.82 45.9 26.6 35.88 56.89 68.4 40.18 66.65 48.11 81.26 60.93 71.24 30.05 31.97 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open S

Page 8 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY 40 Prepared for: GZA 105836 - mw67i.xls depth (feet) 233.46 233.57 234.85 235.75 235.96 236.92 237.66 238 238.46 239.9 240.35 244.22 244.39 244.72 244.86 245.15

.245.4 245.69 245.9 246.03 246.62 247.7 248.07 249.33 250.03 250.1 250.31 250.61 250.79 250.97 251.21 252.2 252.28 252.51 252.56 252.88 253.2 253.58 253.7 253.96 254.18 O 254.33 254.4 254.55 down-dip compass azimuth (degrees) 102.97 330.04 124.92 127.27 352.45 281.92 116.75 118.21 295.47 341.54 26.33 140.43 332.41 43.47 298.98 121.34 124.97 114.34 119.2 119.2 121.77 329.25 111.64 338.82 338.23 340.16 341.31 355.65 333.56 347.82 346.66 355.82 4.83 109.46 116.17 324.65 344.67 349.67 108.44 95.13 190.25 106.5 294.77 285.04 dip angle (degrees) 49.58 57.59 59.51 45.84 65.23 19.01 55.68 50.12 43.36 61.1 73.9 49.32 71.72 30.31 29.98 42.7 52.18 52.67 52.2 52.14 56.09 66.69 42.2 58.63 56.9 57.78 52.17 62.41 50.58 59.71 56.54 62.4 59.16 44.65 51.66 33.13 53.97 54.17 42.94 40.23 38.88 31.86 58.97 49.66 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 9. of, 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 254.61 106.52 37.12 less-open 254.96 110.09 28.37 less-open 255.2 99.62 39.6 less-open 255.24 343.52 68.83 less-open 255.56 352.44 68.07 less-open 256.09 105.44 41.56 less-open 257.1 112.27 45.91 less-open 257.3 351.26 76.53 less-open 257.44 97.05 34.35 less-open 258.58 188.99 84.17 less-open 259.28 113.01 62.31 less-open 259.92 354.62 77.79 less-open 260.82 354.71 77.56 less-open 261.25 352.49 80.01 less-open 261.43 109.94 67 less-open 261.58 357.47 76.58 less-open 262.6 354.53 83.34 less-open 262.71 328.47 34.86 less-open 262.77 333.42 28.6 less-open 262.92 316.43 27.58 less-open 263.21 109.44 46.47 less-open 263.55 304.16 59.64 less-open 264.85 119.73 50.52 less-open 265.04 116.22 48.51 less-open 265.3 117.35 60.48 less-open 265.51 349.33 78.79 less-open 265.82 115.72 47.01 less-open 266.2 346.61 72.49 less-open 266.31 322.38 58.28 less-open 266.71 73.22 60.38 less-open 267 61.38 62.1 less-open 267.69 122.42 48.71 less-open 267.88 65.82 76.42 less-open 268.32 334.82 62.39 open 268.48 321.8 57.88 less-open 268.68 330.71 70.06 less-open 269.16 342.06 67.28 less-open 269.28 341.3 62.55 less-open 269.57 121 46.42 less-open 269.91 111.37 62.53 less-open 269.99 341.17 74.91 less-open 270.34 132.53 46.04 less-open 270.5 321.55 54.74 less-open 270.96 32.23 24.54 less-open Page 10 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: OZA 105836 - mw67i.xls depth (feet) 271.77 272.43 273.19 274.02 274.82 275.32 275.5 276.26 276.36 276.47 276.75 276.89 277.73 277.99 278.4 278.57 O 279.91 280.01 280.34 280.82 280.95 281.18 281.73 282.15 282.72 282.77 282.88 283.98 285.37 286.52 287.64 287.9 288.15 288.23 288.23 288.33 288.47 288.66 290.53 290.72 291.17

.291.5 292.38 293.27 down-dip compass azimuth (degrees) 333.34 120.11 316.51 172.61 170.35 123.78 133.52 311.15 309.79 311.22 316.57 319.77 182.23 346.04 347 224.02 324.13 143.87 133.51 148.22 138.04 142.02 124.93 330.66 346.89 324.08 126.34 288.8 339.67 298.28 283.55 296.84 139.56 124 307.26 144.78 128 112.43 303.72 309.21 306.01 313.58 327.15 267.07 dip angle (degrees) 55.66 48.41 39.86 75.74 44.48 39.27 52.64 44.95 40.68 51.82 37.79 37.09 56.4 74.18 70.77 20.46 42.46 42.13 39.91 46.88 44.54 44.93 44.4 48.8 66.37 36.31 56.23 22.41 61.38 68.16 24.78 73.64 40.09 38.51 72.25 41.82 53.19 55.52 79.05 58.71 46.3 39.27 51.84 75.88 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 11 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - mw67i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 293.35 348.8 44.17 less-open 294.94 303.29 33.74 less-open 295.94 286.86 30.32 less-open 296.75 295.71 44.93 less-open 298.89 94.5 57.99 less-open 301.24 114.52 36.62 less-open 301.28 140.69 45.56 less-open 301.53 112.5 52.03 less-open 301.99 76.34 65.3 less-open 302.53 348.53 45.5 less-open 302.62 101.83 50.54 less-open 302.63 338.76 50.85 less-open 302.78 131.4 30.04 less-open 302.89 326.77 51.97 less-open 302.98 326.01 54.75 less-open 303.06 99.07 55.62 less-open 303.23 105.66 48.9 less-open 303.36 326.15 52.41 less-open 303.63 333.18 55.53 less-open 303.78 306.16 34.56 less-open 303.96 127.25 49.87 less-open 304.42 337.37 23.63 less-open 304.43 119.96 52.43 less-open 304.57 120.81 47.62 less-open 304.7 100.84 57.37 less-open 304.75 146.97 34.46 less-open 304.77 323.9 36.73 less-open 305.12 123.36 47.54 less-open 305.52 331.02 53.53 less-open 306.65 325.5 50.83 less-open 308.35 170.02 48.13 less-open 308.74 316.59 53.17 less-open 308.86 110.12 41.37 less-open 309.23 337.69 67.75 less-open 309.64 306.86 63.02 less-open 310.28 123.5 45.9 less-open 311.91 125.65 45.35 less-open 313.23 172.72 43.66 less-open 313.41 194.1 52.02 less-open 313.81 133.97 45.58 less-open 315.1 178.69 42.09 less-open 315.62 156.26 45.65 less-open 316.36 116.02 44.64 less-open 316.66 121.77 36.29 less-open Page 12 of 13

Fracture Orientations Interpreted from MW-67 Acoustic Televiewer Log Indian Point Site

. Buchanan, NY Prepared for: GZA 105836 - mw67i.xls depth (feet) 318.2 321.7 322.52 324.79 324.94 325.2 325.83 326.35 326.38 326.7 326.92 327.09 327.18 327.25 327.44 327.77 328.32 328.42 328.75 328.95 329.39 329.71 329.84 329.97 332.51 333.59 334.4 334.53 335.73 335.82 336.02 336.78 337.91 down-dip compass azimuth (degrees) 264.89 345.84 326.26 355.46 354.22 133.66 116.85 84.85 95.84 92.13 120.62 133.81 342.4 117.36 297.04 138.65 111.04 95 118.57 123.47 129.95 113.89 114.28 116.57 337.86 337.13 104.55 326.15 67.24 219.16 295.18 287.45 218.78 dip angle (degrees) 26.31 75.33 64.07 51.14 45.36 50.55 59.07 41.55 66.25 42.06 61.35 37.99 61.29 57.42 38.86 40.12 40.69 70.18 63.83 58.16 50.85 48.32 39.07 46.26 48.59 60.34 50.05 38.93 43.85 37.64 33.32 83.11 41.71 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Page 13 of 13

Fracture Orientations Interpreted from RW-1 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - rw1 i.xls 0

depth (feet) 30.12 30.65 30.88 32.63 32.95 33.76 34.17 34.63 35.19 36.39 36.92 38.55 38.55 38.73 41.34 42.85 43.36 44.05 45.27 46.47 47.00 47.24 47.97 48.60 49.62 50.41 51.24 51.55 52.01 52.47 53.06 53.69 53.92 54.27 54.75 55.28 55.56 55.81 56.53 56.83 57.17 57.22 58.30 58.47 down-dip compass azimuth (degrees) 132.5 136.9 142.7 182.9 168.8 160.5 175.3 161.6 171.3 175.6 104.6 303.6 170.5 9.7 154.3 171.9 154.6 167.2 206.2 188.2 179.5 170.0 165.1 191.3 187.1 191.5 169.6 170.6

.182.2 184.4 189.9 180.5 190.8 174.47 150.1 162.5 165.54 152.59 155.2 153.2 348.0 164.4 189.6 184.5 dip angle (degrees) 48.5 53.6 48.5 54.9 52.6 49.4 43.0 50.4 46.5 51.0 28.7 68.4 50.6 66.7 40.3 52.1 47.6 67.4 15.2 69.4 56.6 53.5 51.8 64.1 54.9 61.6 48.3 52.5 51.3 52.9 51.4 59.2 55.1 52.55 44.4 49.2 55.28 49.12 51.3 52.5 36.3 57.5 50.3 54.8 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open Note that down-dip compass azimuth is perpendicular to the strike direction.

Note that interpreted down-dip compass azimuths are with respect to magnetic north.

Down-dip azimuths & dip angles were corrected for borehole deviation from vertical.

0 Page 1 of 3

Fracture Orientations Interpreted from RW-1 Acoustic Televiewer Log Indian Point Site SBuchanan, NY is Prepared for: GZA 105836 - rwl i.xls depth (feet) 58.80 59.60 59.93 60.08 61.2 61.36 61.77 61.95 62.72 63.12 63.22 64.71 64.77 65.31 65.50 65.87 S66.33 66.60 67.32 67.70 68.53 69.58 69.85 70.08 73.89 75.33 79.44 81.07 83.58 83.71 83.82 84.06 87.09 87.31 97.98 100.46 100.84 103.13 111.58 111.82 114.91 O 116.19 117.18 119.45 down-dip compass azimuth (degrees) 172.1 148.4 168.2 166.76 134.08 144.4 150.6 149.2 285.5 263.1 126.99 154.72 298.4 129.0 302.3 201.1 218.7 172.0 139.3 150.3 351.6 194.5 158.6 162.2 324.2 109.3 135.7 242.2 114.4 122.3 112.7 202.7 166.2 299.8 183.8 125.5 328.4 194.6 287.9 141.5 146.0 154.43 116.62 122.1 dip angle (degrees) 58.1 47.7 48.7 47.7 49.41 42.5 53.5 53.6 65.8 57.3 67.86 44.73 66.0 46.1 63.7 52.4 28.6 46.2 40.0 40.6 4.7 43.6 46.8 46.0 62.2 32.8 35.3 63.6 45.7 50.0 48.3 54.7 42.2 24.5 42.7 32.1 48.8 54.0 49.2 43.8 52.9 51.91 61.61 42.9 interpreted planar feature category less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-;open less-open less-open less-open less-open less-open open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open less-open open less-open less-open Page 2 of 3

Fracture Orientations Interpreted from RW-1 Acoustic Televiewer Log Indian Point Site Buchanan, NY Prepared for: GZA 105836 - rwl i.xls down-dip interpreted compass dip planar depth azimuth angle feature (feet)

(degrees)

(degrees) category 120.34 108.7 33.7 less-open 124.07 229.6 30.8 less-open 127.11 152.4 84.5 less-open 127.16 182.4 41.8 less-open 129.71 309.2 48.9 less-open 134.61 284.5 46.5 less-open 135.67 263.7 47.0 less-open 136.95 322.0 43.0 less-open 137.89 290.6 45.2 less-open 138.51 293.1 43.1 less-open 138.64 286.6 43.4 less-open 139.11 273.7 27.2 less-open Page 3 of 3