February 11, 2008 LICENSEE:

Southern Nuclear Operating Company, Inc.

FACILITY:

Vogtle Electric Generating Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON JANUARY 25, 2008, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND SOUTHERN NUCLEAR OPERATING COMPANY, INC., CONCERNING REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE VOGTLE ELECTRIC GENERATING PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Southern Nuclear Operating Company, Inc., held a telephone conference call on January 25, 2008, to discuss and clarify the staffs request for additional information (RAI) and audit database questions concerning the Vogtle Electric Generating Plant, Units 1 and 2, license renewal application. The telephone conference call was useful in clarifying the intent of the staffs RAIs.

provides a listing of the participants and Enclosure 2 contains a summary of the discussions and a listing of the RAIs; and database questions discussed with the applicant, including a brief description on the status of the items.

The applicant had an opportunity to comment on this summary.

/RA/

Donnie J. Ashley, Sr. Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-424 and 50-425

Enclosures:

As stated cc w/encls: See next page

ML080250159 OFFICE LA:DLR PM:RPB1:DLR BC:RPB1:DLR NAME SFigueroa DAshley LLund DATE 01/30/08 01/30/08 02/11/08

ENCLOSURE 1 TELEPHONE CONFERENCE CALL VOGTLE ELECTRIC GENERATING PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS JANUARY 25, 2008 PARTICIPANTS AFFILIATIONS Donnie Ashley NRR/DLR/RPB1 Lambros Lois NRR Chalmer Myer Southern Company John Hornbuckle Southern Company Stanley Anderson Westinghouse Corp

ENCLOSURE 2

SUMMARY

OF TELEPHONE CONFERENCE VOGTLE ELECTRIC GENERATING PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION JANUARY 25, 2008 The U.S. Nuclear Regulatory Commission (NRC or the staff), representatives of Southern Nuclear Operating Company, Inc., and Westinghouse Corporation held a telephone conference call on January 25, 2008, to discuss and clarify the following draft request for additional information (D-RAI) concerning the Vogtle Electric Generating Plant (VEGP), Units 1 and 2, license renewal application (LRA).

D-RAI 4.2-1 In Section 4.2.1, the LRA discusses Neutron Fluence. The following information is required to complete the review of this section:

Specify the method used to determine the End of Life (EOL) Pressure Vessel Fluence.

Has this method been benchmarked? If so, please describe methods used to benchmark the results.

Assuming the method is referenced in the Pressure Temperature Limits Report (PTLR),

please make the PTLR available to the staff.

If plant specific measured values (from the surveillance capsules) are used, please make the capsule report available to the staff.

D-RAI 4.2-2 In the LRA on page 4.2-2, Tables 4.2.1-1 and 4.2.1-2, show values for 1/4T and 3/4T. What method was used to calculate the 1/4T and 3/4T values used in these tables?

D-RAI 4.2-3 In the LRA on page 4.2.-2, Table 4.2.1-2, please specify the method, azimuthal location and elevation above the beltline region used to determine the extended beltline peak fluence values.

The applicant understands the questions and the information will be sent as formal RAIs.

Letter to Southern Nuclear from Donnie Ashley, dated February 11, 2008 DISTRIBUTION:

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON JANUARY 25, 2008, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND SOUTHERN NUCLEAR OPERATING COMPANY, INC., CONCERNING REQUEST FOR ADDITIONAL INFORMATION PERTAINING TO THE VOGTLE ELECTRIC GENERATING PLANT, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION HARD COPY:

DLR RF E-MAIL:

PUBLIC SSmith (srs3)

SDuraiswamy RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDciCvib RidsNrrDciCpnb RidsNrrDraAfpb RidsNrrDeEmcb RidsNrrDeEeeb RidsNrrDssSrxb RidsNrrDssSbpb RidsNrrDssScvb RidsOgcMailCenter DAshley JPLeous BSingal CJulian, RII GMcCoy, RII BAnderson, RII

Vogtle Electric Generating Plant, Units 1 and 2 cc:

Mr. Tom E. Tynan Vice President - Vogtle Vogtle Electric Generating Plant 7821 River Road Waynesboro, GA 30830 Mr. N. J. Stringfellow Manager, Licensing Southern Nuclear Operating Company, Inc.

P.O. Box 1295 Birmingham, AL 35201-1295 Mr. Jeffrey T. Gasser Executive Vice President Southern Nuclear Operating Company, Inc.

P.O. Box 1295 Birmingham, AL 35201-1295 Mr. Steven M. Jackson Senior Engineer - Power Supply Municipal Electric Authority of Georgia 1470 Riveredge Parkway, NW Atlanta, GA 30328-4684 Mr. Reece McAlister Executive Secretary Georgia Public Service Commission 244 Washington Street, SW Atlanta, GA 30334 Mr. Harold Reheis, Director Department of Natural Resources 205 Butler Street, SE, Suite 1252 Atlanta, GA 30334 Attorney General Law Department 132 Judicial Building Atlanta, GA 30334 Mr. Laurence Bergen Oglethorpe Power Corporation 2100 East Exchange Place P.O. Box 1349 Tucker, GA 30085-1349 Arthur H. Domby, Esquire Troutman Sanders Nations Bank Plaza 600 Peachtree Street, NE Suite 5200 Atlanta, GA 30308-2216 Resident Inspector Vogtle Plant 8805 River Road Waynesboro, GA 30830 Office of the County Commissioner Burke County Commission Waynesboro, GA 30830 Mr. Stanford M. Blanton, Esq.

Balch & Bingham, LLP P.O. Box 306 Birmingham, AL 35201 Ms. Moanica M. Caston Vice President and General Counsel Southern Nuclear Operating Company, Inc.

40 Inverness Center Parkway P.O. Box 1295 Birmingham, AL 35201-1295 Chalmer R. Myer Southern Nuclear Operating Company, Inc.

40 Inverness Center Parkway P.O. Box 1295 Birmingham, AL 35201-1295