December 13, 2007 William Levis President and Chief Nuclear Officer PSEG Nuclear LLC 80 Park Plaza, T4B Newark, NJ 07102

SUBJECT:

CHANGE TO THE INSPECTION PLAN FOR THE HOPE CREEK GENERATING STATION

Dear Mr. Levis:

As part of a periodic self-assessment, the Nuclear Regulatory Commission (NRC) thoroughly reviewed the inspection procedures to ensure the continued effective application of inspection resources. The main objective of the review was to determine the appropriate inspection scope for the majority of the inspection procedures in the reactor oversight process (ROP). The result of this effort (designated ROP realignment) created changes to both inspection scope and/or inspection frequency for selected inspection procedures in the ROP. The purpose of this letter is to update the schedule of future inspection activities at your facility that was provided with the mid-cycle assessment letter in August 2007. Please note that there were no changes made to inspection procedures in the security, emergency preparedness, and health physics areas.

The enclosed inspection plan details the inspections (less those related to physical protection) scheduled for calendar year 2008. The inspection plan is provided to resolve any scheduling and/or personnel availability issues well in advance of the inspector(s) arrival onsite. Routine resident inspections are not listed due to their continuous nature.

In accordance with 10 CFR 2.390 of the NRCs Rules and Practices a copy of this letter and its enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of the NRCs document system (ADAMS).

W. Levis 2

ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (The Publlic Electronic Reading Room).

Please contact me at 610-337-5069 with any questions you may have regarding this letter or the inspection plan.

Sincerely,

/RA/

Mr. Arthur Burritt, Chief Projects Branch 3 Division of Reactor Projects Docket No. 50-354 License No. NPF-57

Enclosures:

Hope Creek Generating Station Inspection/Activity Plans cc w/encl:

T. Joyce, Senior Vice President, Operations G. Barnes, Site Vice President K. Chambliss, Director, Nuclear Oversight B. Clark, Director of Finance J. Perry, Hope Creek Plant Manager J. Keenan, General Solicitor, PSEG M. Wetterhahn, Esquire, Winston and Strawn, LLP Consumer Advocate, Office of Consumer Advocate, Commonwealth of PA L. Peterson, Chief of Police and Emergency Management Coordinator P. Baldauf, Assistant Director, NJ Radiation Protection Programs P. Mulligan, Acting Manager, NJ Bureau of Nuclear Engineering H. Otto, Ph.D., Adminstrator, DE Division of Water Resources N. Cohen, Coordinator - Unplug Salem Campaign E. Zobian, Coordinator - Jersey Shore Anti Nuclear Alliance ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (The Public Electronic Reading Room).

W. Levis 2

Please contact me at 610-337-5069 with any questions you may have regarding this letter or the inspection plan.

Sincerely,

/RA/

Mr. Arthur Burritt, Chief Projects Branch 3 Division of Reactor Projects Docket No. 50-354 License No. NPF-57

Enclosures:

Hope Creek Generating Station Inspection/Activity Plans Distribution w/encl:

S. Collins, RA M. Dapas, DRA D. Lew, DRP J. Clifford, DRP A. Burritt, DRP L. Cline, DRP G. Malone, DRP, Senior Resident Inspector T. Wingfield, DRP, Resident Inspector K. Venuto, DRP, Resident OA G. West, RI OEDO (Acting)

J. Lubinski, NRR H. Chernoff, NRR R. Ennis, PM, NRR J. Thompson, NRR (JWT1@nrc.gov)

J. Shea, NRR, Backup Region I Docket Room (with concurrences)

J. Trapp, DRS J. Rogge, DRS M. Sykes, DRS J. White, DRS L. Doerflein, DRS R. Conte, DRS L. Scholl, DRS P. Frechette, DRS D. Silk, DRS D. Screnci, PAO N. Sheehan, PAO R. Barkley, ORA D. Holody, ORA SUNSI Review Complete: LC (Reviewer====s Initials)

DOCUMENT NAME: T:\\DRP\\BRANCH3\\ROP 8 Letters\\HCGSROPrealignment.doc After declaring this document AAn Official Agency Record@ it will be released to the Public.

To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RI/DRP RI/DRP NAME LCline/LC ABurritt/

DATE 12/07/07 12/12/07 OFFICIAL RECORD COPY

Hope Creek Inspection / Activity Plan 01/01/2008 - 12/31/2008 Inspection Type Inspection Activity Planned Dates Start End No. of Staff on Site Title Unit Number Page 1 of 1 12/11/2007 14:27:20 Report 22 1

7112201

- PUB RAD SAFETY - RETS Baseline Inspections 01/28/2008 02/01/2008 1

7112201 IP Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems 4

MODS

- MODS Baseline Inspections 03/31/2008 04/04/2008 1

7111117B IP Permanent Plant Modifications Baseline Inspections 04/14/2008 04/18/2008 1

7111117B IP Permanent Plant Modifications 1

7111107B

- HEAT SINK INSP Baseline Inspections 05/05/2008 05/09/2008 1

7111107B IP Heat Sink Performance 1

71121

- OCC RAD SAFETY Baseline Inspections 05/12/2008 05/16/2008 1

7112101 IP Access Control to Radiologically Significant Areas Baseline Inspections 05/12/2008 05/16/2008 1

7112102 IP ALARA Planning and Controls Baseline Inspections 05/12/2008 05/16/2008 1

7112103 IP Radiation Monitoring Instrumentation and Protective Equipment 4

EP

- EP EXERCISE EVALUATION EP Baseline Inspectio 05/19/2008 05/23/2008 1

7111401 IP Exercise Evaluation EP Baseline Inspectio 05/19/2008 05/23/2008 1

7111404 IP Emergency Action Level and Emergency Plan Changes Baseline Inspections 05/19/2008 05/23/2008 1

71151-EP01 IP Drill/Exercise Performance Baseline Inspections 05/19/2008 05/23/2008 1

71151-EP02 IP ERO Drill Participation Baseline Inspections 05/19/2008 05/23/2008 1

71151-EP03 IP Alert & Notification System 1

DNMS

- ISFSI LOADING CAMPAIGN INSPECTION Other Routine 07/01/2008 09/30/2008 1

60855 IP Operation Of An ISFSI 1

71121

- OCC RAD SAFETY Baseline Inspections 07/21/2008 07/25/2008 1

7112101 IP Access Control to Radiologically Significant Areas Baseline Inspections 07/21/2008 07/25/2008 1

7112102 IP ALARA Planning and Controls Baseline Inspections 07/21/2008 07/25/2008 1

7112103 IP Radiation Monitoring Instrumentation and Protective Equipment 5

7111111B

- REQUAL INSPECTION +P/F REVIEW Baseline Inspections 10/06/2008 10/10/2008 1

7111111B IP Licensed Operator Requalification Program 1

71121

- OCC RAD SAFETY Baseline Inspections 09/29/2008 10/03/2008 1

7112101 IP Access Control to Radiologically Significant Areas Baseline Inspections 09/29/2008 10/03/2008 1

7112102 IP ALARA Planning and Controls Baseline Inspections 09/29/2008 10/03/2008 1

7112103 IP Radiation Monitoring Instrumentation and Protective Equipment Baseline Inspections 09/29/2008 10/03/2008 1

71151 IP Performance Indicator Verification Baseline Inspections 09/29/2008 10/03/2008 1

71151-PR01 IP RETS/ODCM Radiological Effluent This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.