December 20, 2007 LICENSEE:
Indiana Michigan Power Company, LLC (I&M)
FACILITY:
D. C. Cook Nuclear Plant (DCCNP), Units 1 and 2
SUBJECT:
SUMMARY
OF DECEMBER 12, 2007, MEETING WITH I&M ON THE ISSUE OF ICE CONDENSER ICE FUSION (TAC NO. MD6756)
On December 12, 2007, the Nuclear Regulatory Commission (NRC) staff held a Category 1 public meeting with representatives of I&M at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss issues concerning ice fusion in ice condenser baskets (see meeting notice dated November, 2007; Accession No. ML073241026).
The names of meeting participants are as recorded in Enclosure 1. I&Ms presentation followed its handout material (Enclosure 2).
I&M proposed submitting an application for license amendment for long-term resolution to eliminate the need to design for loss-of-coolant accident concurrent with an earthquake for the ice condenser. If such an amendment is approved, then ice basket ice fusion time will cease to be an issue for DCCNP. This amendment would commit I&M to perform an inspection of the ice baskets after an earthquake. The NRC staff indicated that it is receptive to such an amendment, and advised the licensee to submit the application as soon as possible, and hold pre-application discussions with the NRC staff to resolve technical issues on a timely basis.
In the interim to get over the next outage or two, the licensee proposed to rely on operability evaluations to support shorter ice fusion times. The licensee was told that the NRC staff expects to review these evaluations prior to the outages.
Members of the public were not in attendance, and no Public Meeting Feedback forms were completed and submitted.
Please direct any inquiries to me at 301-415-1451, or pst@nrc.gov
/RA/
Peter S. Tam, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316
Enclosures:
As stated cc w/encl: See next page
LICENSEE:
Indiana Michigan Power Company, LLC (I&M) December 20, 2007 FACILITY:
D. C. Cook Nuclear Plant (DCCNP), Units 1 and 2
SUBJECT:
SUMMARY
OF DECEMBER 12, 2007, MEETING WITH I&M ON THE ISSUE OF ICE CONDENSER ICE FUSION (TAC NO. MD6756)
On December 12, 2007, the Nuclear Regulatory Commission (NRC) staff held a Category 1 public meeting with representatives of I&M at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss issues concerning ice fusion in ice condenser baskets (see meeting notice dated November, 2007; Accession No. ML073241026).
The names of meeting participants are as recorded in Enclosure 1. I&Ms presentation followed its handout material (Enclosure 2).
I&M proposed submitting an application for license amendment for long-term resolution to eliminate the need to design for loss-of-coolant accident concurrent with an earthquake for the ice condenser. If such an amendment is approved, then ice basket ice fusion time will cease to be an issue for DCCNP. This amendment would commit I&M to perform an inspection of the ice baskets after an earthquake. The NRC staff indicated that it is receptive to such an amendment, and advised the licensee to submit the application as soon as possible, and hold pre-application discussions with the NRC staff to resolve technical issues on a timely basis.
In the interim to get over the next outage or two, the licensee proposed to rely on operability evaluations to support shorter ice fusion times. The licensee was told that the NRC staff expects to review these evaluations prior to the outages.
Members of the public were not in attendance, and no Public Meeting Feedback forms were completed and submitted.
Please direct any inquiries to me at 301-415-1451, or pst@nrc.gov
/RA/
Peter S. Tam, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316
Enclosures:
As stated cc w/encl: See next page DISTRIBUTION:
PUBLIC LPL3-1 r/f RidsNrrDorlLpl3-1 RidsNrrPMPTam RidsNrrLATHarris RidsOgcRp RidsAcrsAcnwMailCenter RidsNrrOd TBloomer, EDO RIII RidsRgn3Mailcenter DHarrison JBettle NKaripineni JRobinson TLiu, NRR Package: ML0 Summary Accession No.: ML073470330 Meeting Notice Accession No.: ML073241026 Licensee=s Handout Accession No.: ML073480087 OFFICE PM/LPL3-1 LA/LPL3-1 BC/SCVB BC/SBPB BC(A)/LPL3-1 NAME PTam PTam for THarris RDennig DHarrison CMunson DATE 12/18/07 12/18/07 12/30/07 12/30/07 12/30/07 OFFICIAL RECORD COPY
DECEMBER 12, 2007, MEETING BETWEEN NRC AND I&M LIST OF ATTENDEES D.C. COOK NUCLEAR PLANT Name Organization Jerome Bettle Containment & Ventilation Branch, NRR Jeremy Bowen Plant Licensing Branch 2-2, NRR Joe Brady*
NRC Region II (Senior Resident Inspector at McGuire)
Michael Brandon TVA (Watts Bar, Sequoyah)
Kevin Coyne NRC Office of Research Don Hafer I&M (D. C. Cook)
Don Harrison Balance-of-Plant, NRR Randy Hart Duke Energy (Catawba)
George Harrick Duke Energy (Catawba)
David Hills*
Mechanical Engineering Branch, NRC Region III Doug Helms TVA (Watts Bar)
Mel Holmberg NRC Region III Scott Karriker Duke Energy (McGuire)
Brian Kemker*
NRC Region III (Senior Resident Inspector at DCCNP)
David Lewis TVA (Watts Bar, Sequoyah)
Nageswara (Rao) Karipineni Containment and Ventilation Branch, NRR Brendan Moroney Plant Licensing Branch 2-2, NRR Jay Robinson Generic communication & Power Uprate Branch, NRR Andrew Sabisch*
NRC Region II (Senior Resident Inspector at Catawba)
Paul Schoepf I&M (D. C. Cook)
Walid Shaban Duke Energy (McGuire)
Sue Simpson I&M (D. C. Cook)
Larry Smith Westinghouse John Stang Plant Licensing Branch 2-1, NRR Peter Tam Plant Licensing Branch, NRR
- Participation by telephone
Donald C. Cook Nuclear Plant, Units 1 and 2 cc:
Attorney General Department of Attorney General 525 West Ottawa Street Lansing, MI 48913 Township Supervisor Lake Township Hall P.O. Box 818 Bridgman, MI 49106 U.S. Nuclear Regulatory Commission Resident Inspector's Office 7700 Red Arrow Highway Stevensville, MI 49127 Kimberly Harshaw, Esquire Indiana Michigan Power Company One Cook Place Bridgman, MI 49106 Mayor, City of Bridgman P.O. Box 366 Bridgman, MI 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, MI 48909 Susan D. Simpson Regulatory Affairs Manager Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Michigan Department of Environmental Quality Waste and Hazardous Materials Div.
Hazardous Waste & Radiological Protection Section Nuclear Facilities Unit Constitution Hall, Lower-Level North 525 West Allegan Street P. O. Box 30241 Lansing, MI 48909-7741 Lawrence J. Weber, Plant Manager Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106 Joseph Jensen, Site Vice President Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106