Text

SAFEGUARDS INFORMATION

SAFEGUARDS INFORMATION

November 23, 2007

Mr. Christopher M. Crane

President and Chief Nuclear Officer

Exelon Nuclear

Exelon Generation Company, LLC

4300 Winfield Road

Warrenville, IL 60555

SUBJECT:

DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3

SECURITY INSPECTION 05000237/2007201 AND 05000249/2007201

Dear Mr. Crane:

On July 27, 2007, the U.S. Nuclear Regulatory Commission (NRC) completed a security

baseline inspection at the Dresden Nuclear Power Station, Units 2 and 3. The inspection

covered one or more of the key attributes of the security cornerstone of the NRCs Reactor

Oversight Process. The enclosed inspection report documents the inspection results, which

were discussed during a preliminary exit meeting on July 27, 2007, with Mr. Danny Bost and

other members of your staff. During the meeting, we discussed an issue identified during the

inspection that warranted further review by the NRC. On October 11, 2007, a final exit meeting

via telecon was conducted with Mr. Dave Wozniak and other members of your staff to disclose

the results of the NRCs review.

The inspection examined activities conducted under your license as they relate to security and

compliance with the Commissions rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedure and records, observed activities, and interviewed

personnel.

EXEMPT FROM PUBLIC DISCLOSURE

May be exempt from public release under the Freedom of

Information Act (5 U.S.C. 552)

Exemption number: 5___________

Nuclear Regulatory Commission review required before

public release.

Jamie Heisserer NSIR/DSO/DDSO/SPEB___________

Name and organization of person making determination.

Date of determination: 11/23/2007______

Enclosure Contains Safeguards

Information. Upon separation, this page is

decontrolled.

SAFEGUARDS INFORMATION

SAFEGUARDS INFORMATION

C. Crane

-2-

The attached report documents a finding that was determined to have the potential for

significance greater than very low security significance (i.e. greater than Green as determined

by the Physical Protection Significance Determination Process). The final resolution of this

finding will convey the increment in the importance to security by assigning the corresponding

color, which may require additional NRC inspection. The deficiency was promptly compensated

for, and the site was in compliance with applicable physical protection and security requirements

within the scope of the inspection before the inspectors left the site. The finding also had a

cross-cutting aspect in the area of Human Performance because personnel failed to conduct an

adequate effectiveness review.

The finding was NRC-identified.

Since the NRC has not made a final determination in this matter, no Notice of Violation is being

issued for the inspection findings at this time. In addition, please be advised that the number

and characterization of any apparent violation described in the enclosed inspection report may

change as a result of further NRC review.

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter will be

available electronically for public inspection in the NRC Public Document Room or from the

Publicly Available Records (PARS) component of NRCs document system ADAMS. ADAMS is

accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (The Public

Electronic Reading Room). However, because of the security-related concerns contained in the

enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosures will not be

available for public inspection.

In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for

your response, if any. This practice will ensure that your response will not be made available

electronically for public inspection in the NRC Public Document Room or from the NRCs

document system ADAMS. If Safeguards Information is necessary to provide an acceptable

response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark

your entire response Security Related Information - Withhold under 10 CFR 2.390 and follow

the instructions for withholding in 10 CFR 2.390(b)(1).

Sincerely,

/RA/

Richard P. Correia

Deputy Director for Operations,

Division of Security Operations

Office of Nuclear Security and Incident Response

Enclosure Contains Safeguards

Information. Upon separation, this page is

decontrolled.

SAFEGUARDS INFORMATION

SAFEGUARDS INFORMATION

Letter to Christopher M. Crane from Richard Correia dated 11/23/07.

SUBJECT:

DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3

SECURITY INSPECTION 05000237/2007201 AND 05000249/2007201

Docket Nos. 50-237; 50-249

License Nos. DPR-19; DPR-25

Nonpublic Enclosure: Inspection Report 05000237/2007201;

05000249/2007201

w/Attachment: Supplemental Information

cc w/encl (SAFEGUARDS INFORMATION):

D. Combs, Security Manager

Dresden Nuclear Power Station

Exelon Generation Company, LLC

6500 North Dresden Road

Morris, IL 60450

cc w/o encl (SAFEGUARDS INFORMATION):

COL Jill Morgenthaler

Deputy Chief of Staff of Public Safety

Homeland Security Advisor

207 State House

Springfield, IL 62706

Distribution w/encl:

SPEB R/F - C. Grigsby, SPEB

D. Riffle, DDSO/DSO

C. Phillips, SRI Dresden

J. Maynen, R-III

Distribution w/o encl:

C. Gratton, PM - NRR

A. McLeod - PMDA

Accession No.: ML073300290

  • See previous concurrence

Publicly Available

Non-Publicly Available

Sensitive

Non-Sensitive

To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy

OFFICE

TL:DSO/NSIR

BC:RIII/DRS

BC:DSO/NSIR

DD:DSO/NSIR

NAME

DBradfield

EDuncan

RAlbert

RCorreia

DATE

11/21/2007

11/23/2007

11/21/2007

11/23/2007

OFFICIAL RECORD COPY

Enclosure Contains Safeguards

Information. Upon separation, this page is

decontrolled.

SAFEGUARDS INFORMATION

SAFEGUARDS INFORMATION

Letter to Christopher M. Crane from Richard Correia dated 11/23/07.

SUBJECT:

DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3

SECURITY INSPECTION 05000237/2007201 AND 05000249/2007201

Docket Nos. 50-237; 50-249

License Nos. DPR-19; DPR-25

Nonpublic Enclosure: Inspection Report 05000237/2007201;

05000249/2007201

w/Attachment: Supplemental Information

cc w/encl (SAFEGUARDS INFORMATION):

D. Combs, Security Manager

Dresden Nuclear Power Station

Exelon Generation Company, LLC

6500 North Dresden Road

Morris, IL 60450

cc w/o encl (SAFEGUARDS INFORMATION):

COL Jill Morgenthaler

Deputy Chief of Staff of Public Safety

Homeland Security Advisor

207 State House

Springfield, IL 62706

Distribution w/encl:

SPEB R/F - C. Grigsby, SPEB

D. Riffle, DDSO/DSO

C. Phillips, SRI Dresden

J. Maynen, R-III

Distribution w/o encl:

C. Gratton, PM - NRR

A. McLeod - PMDA

Enclosure Contains Safeguards

Information. Upon separation, this page is