SRO-NERP-12, the Fishes of the Savannah River Plant: National Environmental Research Park
ML073240718
Person / Time
Site: Vogtle  
Issue date: 08/31/1983
From: Bennett D, Mcfarlane R
E. I. duPont de Nemours & Co, Savannah River Lab, Univ of Georgia
To:
Office of Nuclear Reactor Regulation
References
NL-07-2097 SRO-NERP-12
Download: ML073240718 (156)


Text

{{#Wiki_filter:,-----------NOTICE------------, This report was prepared as an account of work sponsored by the United States Government. Neither the United States nor the United States Depart-ment of Energy, nor any of their contractors, subcontractors, or their employ-ees, makes any warranty, express or implied or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any information, apparatus, product or process disclosed, or represents that its use would not infringe privately owned rights. A PUBLICATION OF DOE'S SAVANNAH RIVER PLANT NATIONAL ENVIRONMENTAL RESEARCH PARK Copies may be obtained from Savannah River Ecology Laboratory

THE FISHES OF THE SAVANNAH RIVER PLANT: NATIONAL ENVIRONMENTAL RESEARCH PARK by 1 David H. Bennett Savannah River Ecology Laboratory University of Georgia and Robert w. McFarlane2 Savannah River Ecology Laboratory and Savannah River Laboratory E. I. duPont de Nemours and Co. Aiken, South Carolina 29801 1Associate Professor, Fishery Resources, College of Forestry, Wildlife and Range Sciences, University of Idaho, Moscow, Idaho 83843 2E lS" B &RtI nV1ronmenta

c1ent1st, rown 00, nc.,

P. O. Box 3, Houston, Texas 77001

TABLE OF CONTENTS Subject Introduction The Savannah River Plant Groundwater and Surface Water Aquatic Habitat Types Historical Aspects Collection of Samples Measurements I Species Accounts List of Fishes Collected on the Savannah River National Environmental Research Park Relative Abundance of Fishes in Riverine Ecosystems Relative Abundance of Fishes in Lentic Ecosystems A Key to Fish Families A Key to Species and Species Descriptions Order Acipenseriformes Acipenseridae - Sturgeon Family Order Semionotiformes Lepisosteidae - Gar Family Key to Species of Lepisosteus Order Amiiformes Amiidae - Bowfin Family Order Anguilliformes Anguillidae - Eel Family 1 Page 4 6 10 11 17 19 20 25 26 30 39 46 55 55 55 55 55 55 57 57 57 57

I1* I 2 Table of Contents (continued) Subject Order Clupeiformes Clupeidae - Herring Family Key to Species of Family Clupeidae Order Salmoniformes Umbridae - Mudminnow Family Esocidae - Pike Family Key to Species of Esox Order Cypriniformes Cyprinidae - Minnow Family Key to Species of Family Cyprinidae Catostomidae - Sucker Family Key to Species of Family Catostomidae Order Siluriformes Ictaluridae - Catfish Family Key to Species of Family Ictaluridae Order Percopsiformes Amblyopsidae - Cavefish Family Aphredoderidae - Pirate Perch Family Order Atheriniformes Belonidae - Needlefish Family Cyprinodontidae - Killifish Family Poeciliidae - Topminnow Family Atherinidae - Silverside Family 58 58 59 63 63 63 64 65 65 66 78 79 83 83 83 90 90 91 92 92 93 94 95

Table of Contents (continued) Subject Order Perciformes Percichthyidae - Temperate Bass Family Key to Species of Family Percichthyidae Centrarchidae - Sunfish Family Key to Species of Family Centrarchidae Percidae - Perch Family Key to Species of Family Percidae Mugilidae - Mullet Family Order Pleuronectiformes Soleidae - Sole Family Problem Species: Possible Misidentifications Glossary Acknowledgments Annotated Bibliography Index Appendix I 3 96 96 97 98 99 113 114 120 121 121 122 124 127 128 144 152

4 INTRODUCTION The objective of this report is to update the taxonomic, distributional, and ecological information on fishes inhabiting waters on and adjacent to the Department of Energy's first National Environmental Research Park, known as the Savannah River Plant (SRP). Our intent is to provide background infor-mation for biologists initiating ichthyofaunal studies on the SRP. Because of the diversity of backgrounds of ecologists who may incorporate some seg-ment of the ichthyofauna into their research on the SRP, we have purposely omitted use of unnecessary technical terminology. We feel that through this approach, the report will serve a broader audience of ecologists than those formally trained in the fisheries discipline. We also realize that much of the information contained in this document should be modified when additional information is available; consequently, we view this report more as a work-book than a "text." Distributional reports of the ichthyofauna of various drainage systems or areas delimited by state boundaries are common for' many parts of the United States. Accounts and keys of the freshwater fishes of the U. S. are given in maj or contributory works by Eddy (1957, 1969) and Blair et al. (1968). These keys are especially useful for the identification of various fish species when keys more regional in scope are not available. Published checklists and/or keys to fishes in the southeastern U. S. have been completed for several states. Although a comprehensive report of the fishes of South Carolina has not been completed, information reported in proximal areas has been used heavily in this report. Loyacano (1975) pub-lished a checklist of fishes by drainages for South Carolina. Because most of the streams on the SRP drain into the Savannah River, Loyacano's report for the Savannah River drainage was helpful.

5 Another useful report on fishes from the Savannah River drainage is that by Dahlberg and Scott (1971a). Earlier. reports by Fowler (1945) and especially the presentation of fishes of the SRP (Freeman 1954) have been used heavily in fortifying our distributional records. Much energy has been expended in ecological research on fishes that occur on the SRP. Most of the published studies have examined some aspect of* environmental perturbation associated with the operations of the SRP. The original bibliography of these studies (Murphy and Gibbons 1977) and an updated, more-inclusive version (Wiener and Smith 1981) have been invaluable I sources of materials on aquatic studies. Further information regarding many SRP fishes may be found in Smith-Vaniz (1968), Carlander (1969, 1977), Douglas (1974), and Pflieger (1975).

6 THE SAVANNAB RIVER PLANT The Savannah River Plaut, located in west-central South Carolina, in-cludes portions of Aiken, Barnwell, and Allendale counties (Fig. 1). The SRP lies approximately 20 km (12 mi) south of Aiken and 25 km (15 mi) east of Augusta, Georgia. The Savannah River, bordering the SRP on the southwest, is a large (100 m wide), low gradient (maximum 50 cm/km) river having an expan-sive flood plain and several oxbow lakes. The river provides cooling water for the SRP via pumping stations at two large canals. The northwestern boundary of the SRP, which lies within the Atlantic Coastal Plain, is approximately 50 km (30 mi) south of the Fall Line (Fig. 2). Most of the streams on the SRP flow through or originate in the Sand-hills or Upper Coastal Plain and are tributaries of the Savannah River which flows through the Lower Coastal Plain. The relief of this area is slight, including narrow, flat-bottomed, steep-sided valleys and rolling interfluvial areas (Siple 1967). The climate on the SRP is typical of the southern Atlantic Coastal Plain. Precipitation, in the form of rainfall, averages 91-112 cm (36 to 44 in). Snow occurs rarely in the area. Months of highest rainfall are March, July and December. Mean annual temperature is 180 C (640 F). January and July are normally the coldest and warmest months of the year. Land acquired by the U. S. Government for the SRP in 1951 was primarily in pine-hardwood forests or intensively farmed for corn and cotton. Since the time of land acquisition for the SRP, the U. S. Forest Service has con-verted most of the abandoned farm lands into managed, pine tree production sites. Lands not suited for pine planting have progressed toward a scrub oak-longleaf pine climax forest type. A very small proportion of the 780 km2 (~ 300 mi2) area has been developed for the production of nuclear isotopes

7 and disposal of radioactive wastes. Most of the land area encompassed by the SRP is protected from the public by intensive security activities and regu-lations.

8 34 o 50 100 1-1----11----;1 kilometers S RR ~ ~herOke~ York ~~\\::! ~ ~ (

l.,.l~

~ ~ ~. '-h._.-i 1-'-...---,--.:---.. t~/ ~ {Union' Chester !Lanca-Chesterfield. 0 y ~ ~ (!). ".Ul i \\. I ster i ! '0 o.~ 'l.. --t: J &I- ~.. Laurens .~ ._'::-\\.,",,-,'. ~-:::. ~." .I '-, Fairfield ( \\ j-'~to({~' ~ ./.i$."fc~" ./ \\ ! Kershaw.~~~'~oto 2: DI~,

0"

\\"'l!'",~eWberry )..... ,-{ (1",/ to' 'i:<f:> ) ",~, r.................../ \\.Richlan~. .~~ee 'Y"";:-/. \\~~,\\Of ~~""" ';~aluda / '-.\\ 1 ;.'\\...) °""110:\\ ( Horry ">", \\. .\\...,"'/\\Lexington 1\\., ~~.../' ;r-....-,_.~ '\\ C'of( ,~." l.;~_.-{C';)-/" ~o~* ~'~I" .,,~.. \\......-c, O/~y ,,,~ J 't:>~"'O /' '\\ ~b~' Aiken / .........0"11 _\\ I;""~ '\\\\\\\\ ~ ~rangeburg".f '\\ ~ / "..00#. mr....... ..... I I~"o'<'i

jCl'

~ '~ ~ \\ Bam-'.N*T Berkeley -, I berg 'x' o"'C" ,~

..r ",-. "'.\\...,

/ Allen-' ,v" 'I..- dale/'~ Colleton ~ ....~ '\\~. / I' ....j L/ ,o~, ~f!l , \\.. .,oto ~t; /',-', i ,\\,,'1> Jasperi ~. (j~~ \\0' r:et:>~ SO UTH CAROLINA 34 32° 32 L.-.------,..--------------r-----------' BOO Figure 1. Location of the Savannah River Plant in South Carolina.

9 34 E:~:~:~:::I-Mountains f.=-.=-..:-]-Piedmont Ei¥#k)l-Sandhills ~ - Upper Coastal Plain I-:..;***I-Lower Coastal Plain SOUTH CAROLINA 800 Figure 2. Location of the Savannah River Plant in relation to the physio-graphic regions in South Carolina.

10 GROUNDWATER AND SURFACE WATER Quantity and quality of groundwater are affected by four basic geologi-cal formations on the SRP. These geological formations are unconsolidated sedimentary units: the Tuscaloosa Formation; the Ellenton Formation; the Tertiary (Eocene) Limestone; and, the Tertiary (Eocene) Sands (Siple 1967). Each of these formations contains water differing in water quality from that of the others. Test wells in each of these formations have provided information on characteristics of groundwater emanating from these strata (Langley and Marter 1973). Water from the Tuscaloosa Formation is generally low in hard-ness (5 mg/l, CaC03), acidic, and low in dissolved solids. Water from the Ellenton Formation is low in dissolved solids (41 mg/l), low in hardness (median = 19 mg/l CaC03), high in iron (71 mg/l) and sulfate anions. Water from the limestone beds of the Eocene sediments has higher levels of dis-solved solids and higher hardness (median = 72 mg/l CaC03). Water from the Tertiary Sands is similar in chemical composition to that of the Tuscaloosa Formation. o The temperature of water from these formations ranges from 18 to 220 C (65 0 to 71 0 F). Th l' f h d e qua 1ty 0 t e groun water, in turn, reflects the surface water quality. Surface water from the area is generally low in.dissolved solids, iron, and total hardness. The pH of most streams on the SRP ranges from 6 to 7, while the Salkehatchie River is slightly more alkaline (pH N 7.3). The disposal of radioactive wastes in the area has had no measurable effect on the water quality (Siple 1967).

11 AQUATIC HABITAT TYPES Six major aquatic habitat types occur on the SRP: small ponds, reser-

voirs, streams, the Savannah River, the river swamp, and Carolina bays.

The standing waters vary in size from less than 0.1 to 1220 ha << \\ acre to about 2800 acres). Natural flows in the various streams range from less than 0.03 3 to 2.8 m /second (1 to 100 cfs). Small Ponds: A number of small, man-made ponds ranging in surface area from 0.1 to 1.2 ha << \\ to 3 acres) currently exist on the SRP. Some were farm ponds, constructed when the area was still under private ownership and I were stocked with a variety of warmwater fish species. Others have resulted from cooling water canal or other construction projects. Reservoirs: The need for water to cool nuclear production reactors on the SRP resulted in construction of two large impoundments, Par Pond and Pond B. Par Pond currently provides cooling water for a nuclear reactor and consequently receives artificially heated waters. Par Pond is about 1220 ha (2800 acres), including the 64 ha pre-cooling reservoir, Pond C. Par Pond has been the' site of numerous studies primarily directed at evaluating the impact of thermal intrusions on lentic species (Gibbons and Sharitz 1974; Gibbons et al. 1975; Tilly 1975; Murphy and Gibbons 1977; Gibbons, Sharitz and Brisbin 1980; Gibbons and Sharitz 1981). The other reservoir, Pond B (118 ha), is in a post-thermal recovery state. Thermal additions to Pond B ceased in 1964. The resulting responses by the biota in this reservoir have been lightly studied (Parker, Hirshfield, and Gibbqns 1973; Gibbons and Sharitz 1974) and deserve more intensive re-search efforts. Streams: Five major tributaries of the Savannah River are encompassed by the SRP in addition to several smaller streams (Fig. 3). The largest and

12 5 I .,....~ ..,..r-I' ~ ~" .,/ \\..:" .r" '-ve,} ~ o 5 I I I I I kilometers o GEORGIA 11\\1 :.'II '.U: I ,(, Figure 3. SRP collecting stations pampled by the authors from 1974.to 1978. Ii

This is the only 'stream which 13 least disturbed of these is Upper Three Runs, a deep; swift blackwater stream 39 km long with a 490 km2 drainage basin. originates, and has*' a substantial portion of its. watershed, beyond the SRP boundary. Upper Three Runs receives some industrial pollutants from Steed's Pond via Tim's Branch; which joins the strea~ just below the Savannah River Laboratory (SRL) Flowing Streams Lab. Because of this pollution, Tim's Branch has an impoverished ichthyofauna. In contrast, Upper Three Runs"Creek possesses a very rich fauna and is minimally' affected, if at all, by the entry of Tim's Branch. Upper Three Runs Creek has" never been'subjected to ,/ thermal perturbation, and most of its passage through theSRP is beneath an overhead canopy of bottomland hardwood trees. Of similar size is Lower Three Runs, 38 km long with a 465 km2 basin, which arises within the SRP and is encompassed by only a 'narrow corridor of .SRP-owned lands for most of its length. This stream transported thermal effluent from 1953 to 1958. Since that time the impoundment of its upper extremity to create Par Pond has reduced stream flow* considerably and*altered water quality because of input into Par Pond from the 'Savannah River. Sixty different species of fishes have been collected from Upper and Lower Three Runs. Each stream has 55 *species. These streams provide an adequate base for comparison with the smaller' SRP streams which have been subjected to various environmental stresses. Three adjacent streams drain the southern half of theSRP and flow into the floodplain swamp before reaching the river. Four Mile Creek (20 km long, 90 km2 basin) has transported thermal effluent since 1955. Pen Branch (16 km 2

long, 90 km basin) has received thermal effluent since 1954.

Steel Creek (15 km

long, 90 km2 basin) received thermal effluent from 1954 until 1968.

During reactor operations the thermal streams experience temperatures from

(McFarlane 1976). tions is Beaver Dam Creek, which receives thermal effluent from an electric from 1.5 to 13. The greater portion of the stream is inundated by Savannah In addition to thermal stress, During reactor

shutdown, waters with decreasing temperatures are streams.

The limited fauna reported from this stream reflects its small size that is outside of the Savannah River drainage. All of the species known The Salkehatchie River, originating on the SRP, is the only SRP stream River flood waters for lengthy periods. from this segment of the Salkehatchie River are also found in other SRP facility. Its upper reaches are subject to rapid fluctuations in pH, ranging power generating plant and chemical effluent from a heavy water production One small st~eam that des~rves mention because of the high stress condi-tially different and more diverse than those of the undisturbed streams rapidly invaded by numerous fish species. overhead canopy.

Thus, the fishes of post-thermal Steel Creek are substan-these streams have been modified "b.Y increased stream flow which produces
erosion, siltation, aggradation, and the removal of aquatic vegetation and tributaries have also suffered a, decline in species richness (McFarlane 1976).

thermally-stressed segments of the streams. Thermally non-stressed, upstream enter the swamp. These high temperatures exclude fishes from most of the a high near 800 C at the reactor outfall to approximately 40 0 C where they 14 r IIi ii, I' 'IIil I I within the SRP. Savannah River: The Savannah River basin is approximately 28,000 km2, of which 20,800 km2 lies upstream from the SRP. The river gradient in the vicinity of the SRP is 0.12 m/km. The mean annual discharge at this point is 316 m3/second (McFarlane et a1.

1978, 1979).

Peak flow and maximum vari-ability in flow occur in March and April, while the lowest flow and least

15 variability are found during the summer and fall. The 7-day, 10-year minimum 3 flow at the SRP site is estimated to be 160 m /second (~ 5700 cfs). At flood stage the water mass breaches the channel to form a floodplain up to 3 kin 3 wide, and flow may approach 1200 m /second. Stream velocity is approximately 0.74 m/second at mean annual discharge and 0.65 m/second at 7-day, 10-year low flow (McFarlane et al. 1978, 1979). The river characteristics are currently dominated by the release of hypolimnetic water from Clark Hill Reservoir. Its principal effects have been to decrease the incidence of both extreme high and low discharge, and to .I decrease the average river temperature by 30 C (McFarlane et al. 1978). River Swamp: The floodplain swamp bordering the river is the least known aquatic habitat on the SRP from an ichthyofaunal standpoint. Its role as spawning and rearing grounds and as a nutrient sink are both unknown and generally unrecognized. This habitat is very diverse as definite water courses alternate with braided channels and broad flats of barely perceptible water movement. It is also one of the most variable habitats, experiencing depth fluctuations of 4 m or more and the input of thermal effluent from three SRP sources. Fishes.are, at

times, very abundant in the river swamp and certain localities, such as the fabled "Honeyhole," attract large numbers of gar, bowfin and carp during winter.

The logistic difficulties of systematic data collection within the swamp have limited investigations. Oxbow lakes and drying potholes teem with fishes, but little is known regarding their rela-tive abundance. Carolina Bays: Carolina bays, natural aquatic environments found across the coastal plain region of Georgia and the Carolinas, are scattered over the SRP. The most interesting aspect of Carolina bays, from a fishery stand-

!I! i ,I ~: II ' I,: I" 'I,. 'I , i'i 16 point, is that they have widely fluctuating water levels, highly dependent on precipitation. Many of these natural aquatic systems periodically dry up and consequently, provide only temporary habitat for fishes.

17 HISTORICAL ASPECTS The fishes of the study area received little attention from scientific workers until the decision of the United States Atomic Energy Commission to construct the SRP in the early 1950 IS. This action precipitated ichthyo-faunal collecting by three different groups. The Academy of Natural Sciences of Philadelphia (ANSP) initiated bio-logical surveys of the Savannah River in June, 1951 (Academy of Natural Sciences of Philadelphia

1953, 1955,
1957, 1961,
1962, 1963,
1967, 1969,
1970a, 1970b,
1973, 1974a,
1974b, 1976, 1977).

Cursory surveys have been I conducted at upstream and downstream stations almost yearly since then. Complete faunal surveys at these and other stations have occurred at longer, less regular intervals. The numerous ANSP reports provide the longest docu-mentation of fishes occurring at specific localities and collected by identi-cal techniques for the SRP. These reports have emphasized the number of fish species present at each locality over time. They do not, however, provide quantitative information on the relative abundance of each species and were principally designed to examine effects upstream and downstream from the SRP. The upstream station (River Mile 160) was located at the former SRP boundary, property now managed by the U. S. Forest Service. The downstream station (River Mile 123) is a considerable distance below the SRP proper. The reader of these reports should be aware that.channelization of the Savannah River has altered the designated river mile of the original stations by as much as 22 km (14 miles). Simultaneously with the ANSP collections, the U. S. Public Health Ser-vice (USPHS.) sampled fishes throughout a more extensive portion of the Savan-nah River. This baseline study resulted in a single interim report (Gold et al. 1954) which provides an interesting watershed perspective.

18 Beyond the efforts of the ANSP and USPHS, the fishes of the central Savannah River have received very little attention. Although the river has supported both commercial and sports fisheries for many years, its role as a state boundary appears to have diverted the interests of the state agencies toward waterways entirely within their jurisdiction or to the upstream im-poundments. Similarly, most fish ecology studies at the SRP have focused upon onsite aquatic habitats, rather than the river, with emphases on demon-strating the effects of thermal alteration or patterns of radionuclide con-tamination or on gathering basic data on the presence and abundance of spe-cies. The fishes of the streams and ponds of the SRP were studied by the Uni-versity of South Carolina from July 1951 to February 1953 (Freeman

1952, 1954).

The ANSP surveys collected additional information from a single sta-tion on Upper Three Runs during 1951, 1952, and 1956. The subsequent acqui-sition of the Lower Three Runs corridor directed attention to that stream in 1957-58 (Freeman 1958) and 1960-72 (Academy of Natural Sciences of Phila-delphia 1961, 1962, 1963, 1969, 1973). Construction of Par Pond in 1958 and Pond B in 1961 created major lentic habitats on the SRP. Most species of fishes found at these sites inhabited Joyce Branch of Lower Three Runs at the time of impoundment.

However, the presence in Par Pond of a few fish species atypical of headwater tributaries attests to the efficacy of the pumping system in transporting fish as a

result of the entrainment of fish eggs, larvae, and juveniles from the Savan-nah River. These reservoir habitats have attracted the attention of numerous workers of the University of Georgia's Savannah River Ecology Laboratory (SREL) and the Georgia Cooperative Fishery Research Unit.

19 COLLECTION OF SAMPLES Collections of fishes from various aquatic habitats on the SRP have varied with the type of habitat, season, species, and personnel. In general, the collecting techniques used have been suited to the habitat. Most of the smaller streams have been sampled with seines, dip nets, electrofishing, and occasionally rotenone. The riverine habitats (e.g., Upper Three Runs Creek), especially in the lower sections, have been sampled with electrofishing gear from boats, and with seines,

traps, and rotenone.

The Savannah River has been sampled by boat-mounted electrofishing gear, traps, seines, and trammel I nets. The sampling of lentic waters has been conducted with rotenone, boat-mounted electrofishing,

seining, minnow traps, gill and trammel nets, trot
lines, and rod and reel.

Collections of smaller shoreline fishes (Gambusia,

Fundulus, etc.)

and collections in shallow bays and marshes have been made primarily with dip nets. Most fish sampling on the SRP has been qualitative. Samples taken in the early 1950 surveys were more concerned with species composition than in obtaining quantitative estimates of density. The only quantitative sampling has been conducted in Par Pond with largemouth bass (Gibbons and Bennett 1973). Estimates of relative abundance have been developed for Par Pond from rotenone cove samples (Clugston 1973b); estimates of general fish abundance from other waters on the SRP developed in this report, are based on catch/ effort data. Specimens collected during the 1978 survey by the senior author are on deposit at SREL. Some specimens collected by various investigators associ-ated with SREL are also on deposit at the same location. Collections made by McFarlane et al. (1978) are, unfortunately, no longer available. Freeman's collections (1954, 1958) are deposited in the National Museum of Natural History, Washington, D. C.

i'i 20 Distributional reports for SRP fishes are based on recent collections made by the authors during the period of 1974-1978 and surveys conducted prior to plant operations (Freeman 1954). Collections were made at numerous unnamed riverine sites by the authors (Fig. 3) and by other investigators (Fig. 4). Many of the lentic collecting sites are identified by local_names (Fig. 5). MEASUREMENTS Standard methods of measuring and counting scales were employed, but the anatomical nomenclature used throughout this report has been kept as elemen-tary as possible (Figs. 6 and 7). We have purposely avoided using scale counts when possible. If counts must be used, refer to Blair et al. (1968). I The spines and/or soft rays of the pectoral,

pelvic, dorsal and anal fins (Fig.
6) are particularly useful in the identification of fishes in this region.

Spines are never segmented or branched, whereas soft rays are always segmented and may be branched. Formulas are used to describe the number of spines and/or soft rays as follows: the number* of fin spines is written

first, in Roman numerals; and the number of fin rays is written second, in Arabic.

If a space occurs between the spines and soft rays, the two numbers are separated by a dash, whereas if they are united, a comma separates the fin types. For example, a species with a spinous dorsal with six spines and ten soft rays would be written VI,10 (if the spines and rays were separate, the formula would be written as VI-IO). An example of a fin ray count is shown in Fig. 7B.

21 miles I I I 5 I .0 5 I I I I I I ki lometers o I ~ '\\/ GEORG IA Figure 4. Approximate locations of fish collection sites known to have been sampled by previous investigators on the SRP.

I 22 !5 I I ,."f'"-I' ~ ../ \\ .r '-va miles o !5 I I I I I I kilometer, o ~ ,.1',,/ <-t. 2

  • 3

~.4 I GEORGI A ~ LS2J Figure 5. Identification and approximate locations of lentic aquatic eco-systems on the SRP. I. Karen's Pond 13. Craig's Pond 2. A-I Pond 14. Pond C 3. Dry Bay 15. Par Pond 4. Morse Code Bay 16. Pond 4 5. Asphalt Pond 17. Pond 2 6. Risher Pond 18. B Swamp 7. Twin Lakes 19. Pond 9 8. C-5 Bay 20. Steed Pond 9. Dick's Pond 2I. Skinface Pond 10. Moon Lake 22. Ellenton Bay II. Pond B 23. R Canal 12. Sarracenia Bay Sites 6, 7, 9, 20 and 21 are farm ponds. Sites 2, 3, 4, 8, 10, 12, 13, 18, and 22 are Carolina bays.

i 23 2 3 Figure 6. External features of a fish (after Eddy 1957; Blair et al. 1968). A = anal fin; Ad = adipose fin; C = caudal fin; D = dorsal fin; LL = lateral line; No = nostrils; P = pectoral fin; P2 = pelvic fin; 1 = snout length; 2 = total length; 3 = standara length; 4 =body depth (maximum). (See Appendix I).

24 A. Pr -=----= - ---..L~_~ HL Ii, B. Fin ray count Figure 7A. Head of a fish showing external structures (after Bailey, 1951). Ch = cheek; HL = head length; Max = maxilla; Md = mandible; Na = nape; Nos = nostril; Pm = premaxilla; Pre = preopercle; Pr = preorbital length (snout length); Op = opercle; 1 = diam-eter of pupil; 2 = diameter of eye. Figure 7B. Dorsal fin, showing how fin ray counts are made from Hubbs and Lagler 1947). (See Appendix I).

i 25 SPECIES ACCOUNTS . -Seventy-nine species of resident and anadromous fishes have been col-lected on the Savannah River Plant I s National Environmental Research Park (Table 1). These fishes represent 12 orders and 21 families. The following accounts are to assist investigators in rapid identification of the species and to document the distribution of these species in the various aquatic systems on the SRP. Basic ecological information is given to provide preli-minary background knowledge to investigators not familiar with local species on the SRP or with freshwater fishes in general. The following scheme of classifying relative abundance has been used in this report. A abundant: collected in large numbers in suitable habitats during the proper seasons. C common: collected in smaller numbers in suitable habitats during the proper season. U - uncommon: collected occasionally in small numbers in the appropri-ate habitats and seasons. R - rare: seldom encountered at any locality. + - present: collected but abundance is indefinite. ? - questionable presence: reported in literature. The relative distributions of various species collected on the SRP from riverine habitats is shown in Table 2 and from lentic habitats in Table 3. Two lentic habitats (Craig's

Pond, and C-5 Bay) have been sampled without success and fish are presumed absent.

The diverse fauna of Skinface Pond probably reflects the intrusion of species from the Savannah River swamp following flooding. The Par Pond fauna is also affected by the river by means of entrainment, rather than direct migration.

26 Table 1. List of fishes (Class Osteichthyes) collected on the Savannah River National Environmental Research Park Order Acipenseriformes Semionotiformes Amiiformes Anguilliformes Clupeiformes Salmoniformes Cypriniformes Family Acipenseridae Lepisosteidae Amiidae Anguillidae Clupeidae Umbridae Esocidae Cyprinidae Species Acipenser oxyrhynchus Lepisosteus osseus Lepisosteus platyrhincus Amia calva Anguilla rostrata Alosa aestivalis Alosa sapidissima Dorosoma cepedianum Alosa mediocris Dorosoma petenense Umbra pygmaea Esox niger Esox americanus Cyprinus carpio Hybognathus nuchalis Hybopsis rubrifrons Nocomis leptocephalus Notemigonus crysoleucas Notropis chalybaeus Notropis cummingsae Common Name Atlantic sturgeon longnose gar Florida gar bowfin American eel blueback herring American shad gizzard shad hickory shad threadfin shad eastern mudminnow chain pickerel redfin pickerel carp silvery minnow rosyface chub bluehead chub golden shiner ironcolor shiner dusky shiner

Table 1. Continued 27 I Order Cypriniformes Family Cyprinidae (cont. ) Species Common Name Notropis emiliae pugnos.e minnow Notropis hudsonius sJ?ottail shiner Notropis hypselopterus sailfin shiner Notropis leedsi bannerfin shiner Notropis lutipinnis yellowfin shiner Notropis maculatus taillight shiner Notropis niveus whitefin shiner Notropis petersoni coastal shiner Semotilus atromaculatus creek chub Siluriformes Catostomidae Carpiodes cyprinus quillback Erimyzon oblongus creek chubsucker Erimyzon sucetta lake chubsucker Hypentelium nigricans northern hogsucker Minytrema melanops spotted sucker Moxostoma anisurum silver redhorse Ictaluridae Ictalurus brunneus snail bullhead Ictalurus catus white catfish Ictalurus natalis yellow bullhead Ictalurus nebulosus brown bullhead Ictalurus platycephalus flat bullhead Ictalurus punctatus channel catfish Noturus gyrinus tadpole madtom Noturus insignis margined madtom

Cyprinodontidae Fundulus lineolatus Belonidae Strongylura marina ,I 28 Table 1. Continued Order Siluriformes Percopsiformes Atheriniformes Perciformes Family Ictaluridae (cont.) Amblyopsidae Aphredoderidae Poeciliidae Atherinidae Percichthyidae Centrarchidae Species Noturus leptacanthus Pylodictis olivaris Chologaster cornuta Aphredoderus sayanus Gambusia affinis Labidesthes sicculus Morone chrysops Morone saxatilis Acantharchus pomotis Centrarchus macropterus Elassoma zonatum Enneacanthus chaetodon Enneacanthus gloriosus Lepomis auritus Lepomis cyanellus Lepomis gibbosus Lepomis gulosus Lepomis macrochirus Common Name speckled madtom flathead catfish swampfish pirate perch Atlantic needlefish lined topminnow mosquitofish brook silverside white bass striped bass mud sunfish flier banded pygmy sunfish blackbanded sunfish bluespotted sunfish redbreast sunfish green sunfish pumpkinseed warmouth bluegill

Table 1. Continued Order Perciformes I Pleuronectiformes Family Centrarchidae (cont.) Percidae Mugilidae Soleidae Species Lepomis marginatus Lep9mis microlophus Lepomis punctatus Micropterus salmoides Pomoxis annularis Pomoxis nigromaculatus Etheostoma fricksium Etheostoma fusiforme Etheostoma hopkinsi Etheostoma inscriptum Etheostoma olmstedi Etheostoma serriferum Perca flavescens Percina nigrofasciata MugU cephalus Trinectes maculatus 29 Common Name dollar sunfish redear sunfish spotted sunfish largemouth bass wp.ite crappie black crappie Savannah darter swamp darter Christmas darter turquoise darter tessellated darter sawcheek darter yellow perch blackbanded darter striped mullet hogchoker

wo Table 2. Relative abundance of fishes in various riverine ecosystems on the Savannah River Plant. No entry means that no record currently exists of the species in the particular habitat although it has been reported from other areas on the SRP. SPECIES UPPER THREE RUNS CREEK FOUR MILE CREEK PEN BRANCH CREEK . STEEL CREEK LOWER THREE RUNS CREEK SALKEHATCHIE RIVER SAVANNAH RIVER SAVANNAH RIVER SWAMP BEAVER DAM CREEK Atlantic sturgeon (Acipenser oxyrhynchus) longnose gar (Lepisosteus osseus) Florida gar (~. platyrhincus) bowfin (Amia calva) American eel (Anguilla rostrata) blueback herring (Alosa aestivalis) hickory shad (~. mediocris) American shad (~. sapidissima) gizzard shad (Dorosoma cepedianum) C A A + C R C u u C R u C + + C A A + + R C R C A A R A C + + + + + C u C

Table 2. Continued. UPPER FOUR PEN LOWER SAVANNAH* BEAVER THREE RUNS MILE BRANCH STEEL THREE RUNS SALKEHATCHIE SAVANNAH RIVER DAM SPECIES CREEK CREEK CREEK CREEK CREEK RIVER RIVER SWAMP CREEK threadfin shad U (:Q. petenense) eastern mudminnow + + U + R + (Umbra pygmaea) chain pickerel C R + C C + C + (Esox niger) redfin pickerel A U C A C C C (~. americanus) carp + + R U + (Cyprinus ~io) silvery minnow + + + A (Hybognathus nuchalis) rosyface chub + + U (Hybopsis rubrifrons) bluehead chub A C A A + R (Nocomis leptocephalus) golden shiner U C + C C U (Notemigonus crysoleucas) ironcolor shiner C + U C R (Notropis chalybaeus) w I-'

Table 2. Continued. UPPER FOUR PEN LOWER SAVANNAH BEAVER THREE RUNS MILE BRANCH STEEL THREE RUNS SALKEHATCHIE SAVANNAH RIVER DAM SPECIES CREEK CREEK CREEK CREEK CREEK RIVER RIVER SWAMP CREEK quillback R (Carpiodes cyprinus) creek chubsucker C C C C C C R (Erimyzon oblongus) lake chubsucker + C + C C + R (!. sucetta) northern hogsucker C + C R (Hypentelium nigricans) spotted sucker A R A A (Minytrema melanops) silver redhorse C + U (Moxostoma anisurum) snail bullhead U R (Ictalurus brunneus) white catfish + R + R (1.. catus) ye;I.low bullhead C U C C C C R (1.. natalis) brown bullhead + + + + C R (1.. nebulosus) ww

Table 2. Continued. w ~ UPPER FOUR PEN LOWER SAVANNAH BEAVER THREE RUNS MILE BRANCH STEEL THREE RUNS SALKEHATCHIE SAVANNAH RIVER DAM SPECIES CREEK CREEK CREEK CREEK CREEK RIVER RIVER SWAMP CREEK flat bullhead A + C C + C (I. ~atycephalus) channel catfish C U + C + u (!. punctatus) tadpole madtom A U C + + R (Noturus 8Yrinus) margined madtom U U R + (!!. insignis) speckled madtom A + U C + R (!!. leptacanthus) flathead catfish ? (Pylodictis olivaris) swampfish R R R R (Chologaster cornuta) pirate perch A C A A A + R (Aphredoderus sayanus) Atlantic needlefish R (Strongylura marina) lined topminnow U U + C C U R + (Fundulus lineolatus)

Table 2. Continued. UPPER FOUR PEN LOWER SAVANNAH BEAVER THREE RUNS MILE BRANCH STEEL THREE RUNS SALKEHATCHIE SAVANNAH RIVER DAM SPECIES CREEK CREEK CREEK CREEK CREEK RIVER RIVER SWAMP CREEK mosquitofish A A A A A A C + A (Gambusia affinis) brook silversides + C A A C + (Labidesthes sicculus) white bass R (Moron~ chrysops) striped bass + R (~. saxatilis) mud sunfish + + + R + + R (Acantharchus £omotis) flier + + + C + + R + U (Centrarchus macropterus) banded pygmy sunfish U + + R U + R + (Elassoma zonatum) blackbanded sunfish U (Enneacanthus chaetodon) bluespotted sunfish U + C + + R (~. gloriosus) redbreast sunfish A A A A A A + A (Lepomis auritus) w U1

Table 2. Continued. _Q£.l. _-2 1 t !i W 0\\ SPECIES UPPER THREE RUNS CREEK FOUR MILE CREEK PEN BRANCH CREEK STEEL CREEK LOWER THREE RUNS CREEK SALKEHATCHIE RIVER SAVANNAH RIVER SAVANNAH RIVER SWAMP BEAVER DAM CREEK green sunfish + (~. cyanellus) pumpkinseed + (~. gibbosus) warmouth A + + A (~. gulosus) bluegill + + + U (~. macrochirus) dollar sunfish + U + C (~. marginatus) redear sunfish + + + C (~. microlophus) spotted sunfish A A C A (~. punctatus) largemouth bass C C + C (Micropterus salmoides) black crappie + + (Pomoxis nigromaculatus) white crappie (!:. annularis) + C C C + + C + + + + c + R R C A R C u C C R + + + + + + + C u u C A U

Table 2. Continued. UPPER FOUR PEN LOWER SAVANNAH BEAVER THREE RUNS MILE BRANCH STEEL THREE RUNS SALKEHATCHIE SAVANNAH RIVER DAM SPECIES CREEK CREEK CREEK CREEK CREEK RIVER RIVER SWAMP CREEK Savannah darter + + + (Etheostoma fricksium) swamp darter + + + + + R (§.. fusiforme) Christmas darter C U + C R (§.. hopkinsi) turquoise darter (§.. inscriptum) tesselated darter C R + C + R (§.. olmstedi) sawcheek darter + U (§.. serriferum) yellow perch + R + + + C + (Perea flaveseens) blaekbanded darter A + + C A R (Pereina nigrofaseiata) striped mullet U U U U + (MugH eephalus) hogehoker U U U U (Trineetes maeulatus) W ".J

Table 2. Continued. "A - Abundant: collected in large numbers in suitable habitat during the proper season. C - Common: collected most of the time or in smaller numbers in suitable habitat during the proper season. U - Uncommon: collected occasionally in small numbers in the appropriate habitat and season. R - Rare: seldom encountered at any locality. + - Present: collected but abundance is indefinite. ? - Questionable presence: reported in literature. w CD 1 J

~ Table 3. Relative abundance n of fishes from lentic environments on the SRP. See Figure 5 for map of location of the various lentic environments. No entry means that no record currl.*tly exists of the species in the particular habitat although it has been reported from other areas on the SRP. Cl Cl Cl I!l Z z 5 Cl 0 0 5 UJ Cl Cl p. p. p. e! 5 e! H Z Cl p. Z Cl 0 r.Ll Z UJ 5 E-t

i p.
i r.Ll 5

p. p. u C H H P:: I!l U U N ~ E-t z p. I!l r.Ll UJ ~ P. Cl P4 Z Z [il

r:
r:

z z Cl Cl Cl r.Ll Z r.Ll r-l ~ P. UJ H U 0 5 z P:: 5 u, r.Ll H H U

2 I

UJ H ~ H 0 0 E-t H Cl P:: Cl p. UJ P. P. P. I!l UJ UJ r.Ll 0:------- Florida gar + (Lepisosteus ~rhincus) bowfin + + (Amia calva) American eel + + (~uilla rostrata) blueback herring + +. (Alosa aestivalis) gizzard. shad + + + (Dorosoma cepedianum) eastern mudminnow + + (Umbra pygmaea) W \\0

40 TIiNV;) ~ xva NOJ.N::rrI:;I GNOd 3JVaNDIS + u + + + + GNOd G33J.S dWVM$ a C; GNOd + GNOd ~Vd + u + + + + + J GNOd + + + + Ava VIN3::>VlffiVS a OOOd + + "J'.:

Dl\\l'I NOOH
1 ONOd S)lJIO

+

J S::Dl\\l'I NIM.L
J GNOd li3HSnI

+ GNOd.L'IWdS'i A'ia AliO aNOd !-'i u GNOd S I N3li'iX ......j "I:l I "~ v Ul

l

<lJ = Ul

.l

.-l .-l

l

'" ;.l "I:l <lJ

.l V =

'" v v V <lJ;.l = <lJ V V;.l ..II: U V V V C\\l 0 V U .~ =v U

l

..II: a ..c:l = U ..II:.... V = :::l

l Ul

~~ .-l U ..11:...... .... = ~~ Ul .-l III V U ~ ..c:l 0 ~~ Ul a

l
l M

l:l.Ei 'a. v Ul

l 0

V ,0 .-l ..c:l N "I:l

l

.~ >¢I =a <lJ 0 ~.~ V;.l ~.-l V

== v v

.l
.l o '"

IJ.l 0 "I:l;.l Ul;.l

.l =

.-l;.l ,0 "I:l Ul <lJ 0 0 ..II: '" o.... U <lJ VJ:z:/ ..c:l J:z:/I o:z; o:Z; "'J:z:/ l:l.:E: VI-! r,-. u'-' 00'-' u '-' Ul'-'

Table 3. continued ~ 0 0 0 III 5 z 5 0 f'l; 0 z Ul 0 f'l; 0 p.. III p.. p.. 0 ~ z ~ H Z 0 p.. 0 z 0 0 iii Z Ul 5 I:-< =s p.. =s iii 5 ~ p.. u 0 H f'l; H ll': III U U N f'l; ~ f'l; z p.. III f'l; iii Ul ~ p.. 0 ~ 5 ~

t:
t:

Z ~ ~ 0 0 ll': 0 ~ iii

~

r-l ~ p.. Ul H U 5 5 5 Ul iii H H ~ J: Ul ~ ~ H f'l; f'l; I:-< ~ H 0 f'l; 0 p.. Ul p.. p.. p.. III Ul Ul iii ll': brown bullhead + C + (!. nebulosus) flat bullhead + (!. platycephalus) channel catfish + I (!. punctatus) tadpole madtom + (Noturus gyrinus) flathead catfish + (Pylodictis olivaris) + + + pirate perch (Aphredoderus ~anus) lined topminnow + (Fundulus lineolatus) mosquitofish A A A A A + A C + + + + A (Gambusia affinis) ,j:>, I-'

Table 3. continued ~:'----==:::-;'_. -:::- ,j::> l\\.l J] <t: Q Q Q III Z Z ~ Q 0 <t: 0 Z [J) Q .x: Q p., III p., p., 0 ~ z ~ H ~ Q p., 0 Z Q iil ~ [J) 5 ~ ~ p., ~ iil ~ ~ p., U H <t: p:: III U U N <t: Eo< <t: Z p., III <t: iil [J) ~ p., Q rs.. z z ~

r:
r:

z z Q Q Q iil Z iil <t: .-l ~ p., [J) H U 8 5 z p:: z [J) iil H H U ~ .l: ~ H ~ H <t: 0 <t: 0 Eo< H Q p:: Q

l:

p., [J) p., p., p., III [J) [J) iil p:: -------- brook silversides + A + + (Labidesthes sicculus) mud sunfish + (Acantharchus pomotis) flier C + + (Centrarchus macropterus) banded pygmy sunfish + + + + + (Elassoma zonaturn) bluespotted sunfish + (Enneacanthus gloriosus) redbreast sunfish + + + + + + (Lepomis auritus) warmouth + + + + + + + (~. gulosus)

Table 3. continued .:s: Cl Cl Cl p:j Z z 6 Cl 0 .:s: 0 6 en Cl .:s: Cl p.. p:j p.. p.. ~ 6 ~ H 6 Cl p.. Z Cl ~ Z en 6 ~ ~ p.. ~ ~ 6 ~ p.. () 0 H p:: p:j () () N .:s: Eo< .:s: z p.. p:j .:s: ~ en ~ p.. Cl ~ Z z !Q

x:
x:

z z Cl Cl p:: Cl ~ ~ ~ .:s: r-l ~ p.. en H () ~ 6 6 z en ~ H H () ~ I ~ ~ ~ H .:s: .:s: 0 Eo< H .:s: Cl Cl p.. en p.. p.. p.. p:j en en ~ p:: bluegill + + + + A A A + + (1. macrochirus) dollar sunfish + + + + + (1. marginatus) redear sunfish C + + I (1. microlophus) spotted sunfish t t + + (1. punctatus) largemouth bass + A C A + + (Micropterus salmoides) black crappie + + C (Pomoxis nigromaculatus) swamp darter + + + (Etheostoma fusiforme) oJ:>. W

Table 3. continued ~ Cl § Cl IXl e5 ~ e5 Cl e5 (J) Cl l':( ~ 14 IXl 14 14 ~ e5 ~ H Cl 14 Z Cl [il e5 (J) e5 ~ ~ 14

s

[il e5 I 14 CJ ...:l P:: IXl CJ CJ N l':( I:-< l':( Z 14 IXl l':( [il ~ ~ 14 Cl fii: z ~ !il

x:
x:

z z Cl Cl P:: § [il ~ .-l ~ 14 (J) H CJ £ e5 e5 [il H CJ ~ .l: ~ li! ~ H l':( I:-< ...:l Cl Cl 14 (J) 14 14 14 IXl (J) (J) [il P:: yellow perch + + (Perca:flay(:'!scens) Total Species Present 1 1 1 2 5 8 6 1 14 4 17 30 6 2 2 25 1 0 A - Abundant: collected in large numbers in suitable habitat during the proper season C - Common: collected most of the time or in smaller numbers in suitable habitat during the proper season U - Uncommon: collected occasionally in small numbers in suitable habitat and the proper season + - Present: collected but abundance indefinite I - Recently introduced .11:> II:> -Cl

45 Size relationships of a species are often valuable to a researcher. Through the use of regression techniques, a weight estimate for a known length of a species can be determined (Ricker 1973; Carlander 1977). For most SRP species we have provided the expression In W = In a + b(ln TL), where: In =natural logarithm, W=estimated weight (grams) for a fish for a given total length (TL, millimeters), b is the slope of the regression line, and a is the Y-intercept. Also given are the sample size (N) and the corre-lation coefficient (r) of* the regression. To provide further perspective, we have included the maximum size which a species may be expected to attain and i the maximum size reported for SRP specimens (length and weight of a single fish are separated by a comma; when the maximum length and weight were ob-tained from different fish, these are separated by a semicolon). Specific references of interest for a given species are also provided to guide the reader to relevant literature.

46 1. A KEY TO THE FISH FAMILIES OF THE SAVANNAH RIVER PLANT'S NATIONAL ENVIRONMENTAL RESEARCH PARK Caudal fin heterocercal (Fig. 8A) or appears to be homocercal with bony upper lobe (Fig. 8B) 2 Caudal fin typically homocercal (Fig. 8C); both lobes lack bone........ 4 2. Jaws elongate, forming a pointed mouth; (Fig. 9K) body covered with hard, diamond-shaped (ganoid) scales ............................... Ga~ Family - Lepisosteidae page Jaws not elongate; and body mayor may not be covered with ganoid scales 5~ Dorsal fin long, nearly continuous with caudal fin (Fig. IDA); mouth terminal (Fig. 9J) Bowfin Family - Amiidae page 5 Dorsal fin not long; mouth inferior with long barbels (Fig. 9C). .............................. Sturgeon Family - Acipenseridae Jaws elongate; pointed mouth resembling a long beak (Fig. 9L). ..*.............................Needlefish Family - Belonidae page page 5 9 Jaws not elongate................................................*..... Body eel-like; dorsal, caudal, and anal fin continuous (Figs. 9A, lOB). ..........................Freshwater Eel Family - Anguillidae page Body not eel-like; dorsal, caudal, and anal fin not continuous 6. Pectoral fins absent; body flattened; eyes on one side of body (Figs. 11, 9D) Sole Family - Soleidae page 1: Pectoral fins present; body not flattened; eyes on opposite sides f body 7. Head without scales Head with scales 8. Body without scales, conspicuous barbels present above and below mouth (Fig. 9B) Catfish Family - Ictaluridae page Body with scales; barbels absent or inconspicuous 9. Lateral line absent; belly with sawtooth scales (Fig. 90, 12); single dorsal fin without spines Herring Family - Clupeidae page Lateral line present; belly without sawtooth scales; dorsal fin with or without spines

47 10. Dorsal fin with more than 10 rays; lips sucker-like (Fig. 13); pharyn-geal teeth more than 10, always in a single row and "comblike" (Figs. l~B, 9U) Sucker Family - Catostomidae page 78 Dorsal fin with fewer than 10 rays; lips not sucker-like; pharyngeal teeth confined to 2 rows or, if on 1 row, fewer than 6 teeth present (Figs. 14A, 9T) Minnow Family - Cyprinidae page 65 11. Pelvic fins absent; eyes functional but small and covered by skin; anus jugular (Figs. 15A, 9E) Cavefish Family Amblyopsidae page 90 Pelvic fins present; eyes not small and not covered by skin 12 12. Dorsal fin with completely separate spiny and soft-rayed sections...... 13 Dorsal fin with continuous spiny and soft-rayed sections............... 16 13. Anterior dorsal fin with 3-5 spines...... 14 i Anterior dorsal fin with 6 or more spines.............................. 15 14. Lower jaw extending beyond upper jaw; snout dorsoventrally flattened; broad silver lateral stripe; body very thin, pencil-shaped; 1 anal spine (Fig. 9F) Silversides Family - Atherinidae page 95 Lower jaw not extending beyond upper jaw; snout blunt; mouth like an inverted "V"; 2 or 3 anal spines (Fig. 9G) ....................................Mullet Family - Mugilidae page 120 15. Anal spines 3 or more; opercles with well-developed spine; pseudobranch well-developed (Fig. 9H) .......................... Temperate Bass Family - Percichthyidae page 96 Anal spines fewer than 3; opercles with well or poorly developed spine; pseudobranch not well developed (Fig. 9I) ........................................Perch Family - Percidae page 113 16. Mouth large and elongated; jaws duck-bill shaped (Fig. 9N) ..........................................Pike Family - Esocidae page 63 Mouth small and not elongated; jaws not shaped like duck-bill.......... 17 17. Dorsal fin with spines................................................. 18 Dorsal fin without spines 19 18. Anus anterior to usual position, usually under throat (Fig. 15B)j anal spines 2; anal fin origin under posterior base of dorsal fin (Fig. 9M) Pirate Perch Family - Aphredoderidae page 91 Anus located in normal position (immediately anterior to anal fins); anal spines 3; anal fin origin anterior to posterior base of dorsal fin (Fig. 9S) Sunfish Family - Centrarchidae page 98

Ii' I

11 48 19.

Mouth large and terminal; maxillary extends to anterior edge of eye; premaxillaries not protractile (Fig. 9P) .....................................Mudminnow Family - Umbridae page 63 Mouth small and superior; maxillary does not extend to anterior edge of eye; premaxillaries protractile..................................... 20 20. Dorsal fin base almost directly above anal fin base (Fig. 9Q); lateral scales more than 30; third anal ray branched; anal fin of male not modified into elongated intromittent organ ...........................Killifish Family - Cyprinodontidae page 93 Dorsal fin base entirely or almost entirely posterior to anal fin base; lateral scales 30 or fewer; third anal ray not branched (Fig. 9R); anal fin of male modified into elongated intromittent organ ...............................Topminnow Family - Poeciliidae page 94

49 Figure 8. Heterocercal (A - sturgeon only; B - Gars and Bowfin) and homo-ceral (C - all other fishes in report) caudal fins (after Blair et a1. 1968). (See Appendix I).

Percichthyidae Atherinidae Percidae G F J Anguillidae Ictaluridae Sole'idae Acipenseridae c D E

1",

,I Amblyopsidae Amiidae

K 51 I Lepisosteidae L Belonidae Aphredoderidae N Esocidae Clupeidae P Umbridae Q Cyprinodontidae R Poeciliidae s Centrarchidae Cyprinidae Catostomidae Figure. 9. Representatives of fish families occurring on the SRP. (Not drawn to scale).

I 52 A. B. Fig. 10. Body form of

bowfin, Amia
calva, (A) and American eel, Anguilla
rostrata, (B) demonstrating discrete separation of long dorsal fin (A) and continuous dorsal, caudal, and anal fins (B).

Fig. 11. Body form of hogchoker, Trinectes maculatus, demonstrating general location of eyes and fins Fig. 12. Adipose eyelid, ventral sawtooth scales, and elongated dorsal fin ray in gizzard shad, Dorosoma cepedianum.

A. 53 B. Figure 13. Sucker-like lips in silver

redhorse, Moxostoma
anisurum, (A)

(after Blair et al. 1968; see Appendix I); horizontal mouth in spotted

sucker, Minytrema
melanops, (B)

(after Eddy 1957; see Appendix I). A. B. Cyprinidae Catostomidae Figure 14. Comparison of pharyngeal teeth of members of the families Cypri-nidae (A; based on Bl~ir et al. 1968; see Appendix I) and Catos-tomidae (B; Hubbs and Lagler, 1947; see Appendix I).

54 A. Cl1ologosfer cornufo B. Aphredoderus soyonus Figure 15. Jugular location of the anus in swampfish, Chologaster cornuta, (A) and pirate perch, Aphredoderus sayanus, (B).

i 55 A KEY TO SPECIES AND SPECIES DESCRIPTIONS ORDER - ACIPENSERIFORMES STURGEON FAMILY - ACIPENSERIDAE Sturgeons are ancient fishes that retain their primitive features -- a heterocercal caudal fin (Fig. 8A) and cartilaginous skeleton. The body is covered by several rows of bony plates or scutes with a few ganoid scales on the posterior portion. They have an inferior mouth with barbels which facilitate the location of food items. Sturgeons are large fishes and can tolerate a wide variety of salinities. Acipenser oxyrhynchus Mitchill - Atlantic Sturgeon Key Characters: Inferior mouth with barbels. Five series of bony plates on body. Anal rays 23 to 30. SRP Distribution: Rare. A single larva was found in ichthyoplankton samples collected in 1977 in an oxbow channel along the Savannah River. Habitat and Habits: Anadromous, spawning in rivers in the spring. Young sturgeon feed on aquatic invertebrates and gradually migrate to the ocean to mature. Adults occasionally become entangled in commercial shad nets. Size: Maximum body size about 5 m. ORDER - SEMIONOTIFORMES GAR FAMILY - LEPISOSTEIDAE Gars occur in freshwater habitats east of the Rocky Mountains. Two genera (Lepisosteus and Atractosteus) are currently recognized in this family. Gar are primitive fish with much cartilage in their skeleton. Their bodies are long, cylindrically shaped, and covered by thick, ganoid scales. Key to SRP Species of Lepisosteus 1. Snout long and slender, the least width being from 13 to 26 times snout length; no spots on head. .....................................Lepisosteus osseus - longnose gar page 56

56 Snout short and broad, the least width being from 4.5 to 11 times snout length; dark head spots obvious and numerous. Lepisosteus platyrhincus - Florida gar page 56 Lepisosteus osseus (Linnaeus) - longnose gar Key Characters: Snout very long and narrow with many sharp teeth. Body cylindrically shaped with dark spots on body and fins but not on the head. SRP Distribution: Common. Found in Upper Three Runs Creek, Four Mile, Lower Three

Runs, the Savannah River, intake
canals, and the river
swamp, but totally absent from the Par Pond reservoir system.

Habitat and Habits: Primarily found in sluggish water under overhanging cover but often attracted to current. Juveniles grow very rapidly, about 10 cm per month during their first summer. Food of individuals > 5 cm is pri-marily fish; food of smaller individuals is entomostracans and aquatic in-sects. Size: Maximum length is 1.5 m. SRP maximum is 1.3 m, 5 kg. Length-weight relationship (N =41, r = 0.99) is In W= 3.828 (In TL) - 18.16. Lepisosteus platyrhincus DeKay - Florida Gar Key Characters: Snout short and broad. Body cylindrically shaped with dark spots on head. SRP Distribution: Rare. Rarely collected in the Savannah River. It has been collected in the lower section of Steel Creek, Four Mile Creek, an oxbow lake near the mouth of Upper Three Runs, Skinface Pond, and the Savannah River swamp. Habitat and Habits: A species found in sloughs and rivers on the Coastal Plain of South Carolina, Georgia, and Florida. Size: SRP maximum is 69.5 cm, 1.2 kg.

57 ORDER - AMIIFORMES BOWFIN FAMILY - AMIIDAE The bowfin family is an ancient family that has one living species, the bowfin, Amia calva. Bowfin have a cartilaginous skeleton, bony plates that cover the skull and throat area, and cycloid scales that cover the body. This species is easily identified by its long dorsal fin and rounded caudal, pectoral, pelvic and anal fins (Fig. lOA). Amia calva Linnaeus - bowfin I Key Characters: Long dorsal fin nearly reaching to the caudal fin.

Caudal, anal, pelvic, and pectoral fins are rounded.

Males have a dark "eye spot" at caudal base. SRP Distribution: Common. Abundant in the lower sections of major tribu-taries, intake canals, the river, and the Savannah River swamp. Also found in Par Pond and Skinface Pond. Habitat and Habits: Bowfin are found in the sluggish sections of rivers having a muddy bottom. Bowfin spawn in a nest during the spring, but juve-niles are rarely seen, and spawning localities on the SRP are not known. Bowfin feed on a variety of invertebrates and small fishes. Size: SRP maximum is 82 cm, 4.5 kg. Length':'weight relationship (N = 24, r = 0.98) is In W= 2.955 (In TL) - 11.20. ORDER - ANGUILLIFORMES EEL FAMILY - ANGUILLIDAE The family Anguillidae is represented in eastern North America by one

species, the American eel, Anguilla rostrata.

Eels inhabit warm freshwater habitats in the Atlantic and Gulf drainage but are not commonly observed

.J because of their secretive behavior. Females are more frequently encountered in freshwater than males. Anguilla rostrata Lesueur - American eel Key Characters: Elongate body with continuous dorsal, caudal and anal fins. Pectoral fins present; pelvic fins are absent (Fig. lOB). SRP Distribution: Abundant. In small tributaries, creeks and the Savannah River. One of the more abundant species in riverine systems on the SRP. Habitat and Habits: American eels are catadromous, living in freshwater but spawning in the Atlantic Ocean. Juveniles migrate to freshwater streams to mature. Eels feed on live and dead animal matter. Size: Maximum length is 120 cm. SRP maximum is 70 cm,

1. 2 kg.

Length-weight relationship (N = 21, r = 0.99) is In W = 3.456 (In TL) - 15.87. ORDER - CLUPEIFORMES HERRING FAMILY - CLUPEIDAE Although many people regard "herring" as being strictly marine, several species inhabit fresh waters. Five have been found in the Savannah River and its tributaries on the SRP. Three species, the American shad (Alosa sapidis-sima), hickory shad (Alosa mediocris), and blueback herring (Alosa aesti-valis) are anadromous, and consequently, use the Savannah River for spawning and rearing. The threadfin shad, Dorosoma petenense, has been introduced in the Savannah River, but is considered uncommon (McFarlane et a1. 1978). Gizzard shad, Dorosoma cepedianum, are resident throughout the year. Local members of this family are easily identified by the row of saw-toothed scales on the belly and the adipose eyelid (Fig. 12). Species of

59 herring occurring on the

SRP, particularly the juveniles, are moderately difficult to identify because of morphological similarities.

Key to Species of Family Clupeidae: 1. Last ray of dorsal fin greatly elongated into a long filament (Fig. . 12).................................................................... 2 Last ray of dorsal fin not elongated into a long filament.............. 3 2. Anal fin with 25 to 36 rays, usually 29 to 35; mouth noticeably sub-terminal; snout blunt Dorosoma cepedianum - gizzard shad page 62 Anal fin with 17 to 27 rays, usually 20-25; mouth terminal; snout not blunt Dorosoma petenense - threadfin shad page 62 3. Lower jaw projecting beyond upper jaw; 18 to 23 gill rakers on lower limb of gill arch, regardless of size 4 Alosa mediocris - hickory shad page 60 Lower jaw not projecting beyond upper jaw; more than 26 gill rakers on lower limb of gill arch 4 4. Cheek deeper than long; peritoneum pale; 59 to 73 gill rakers in lower limb of first arch in individuals 100-125 mm or more but may be as low as 26 in young (Dahlberg 1975); one or more spots in a longitudi-nal row behind opercle.... Alosa sapidissima - American shad page 61 Cheek not deeper than long; peritoneum usually black; 41 to 52 gill rakers on lower limb of first gill arch in adults; dorsum of adults distinct blue-green Alosa aestivalis - blueback herring page 59 Alosa aestivalis (Mitchill) - blueback herring Key Characters: Peritoneum usually black. Cheek longer than deep. Eye large, the diameter about equal to length of snout. Lower jaw not projecting beyond upper jaw. Teeth in lower jaw. SRP Distribution: Abundant in the Savannah River, Savannah River swamp, and Lower Three Runs Creek and present in Par Pond system. Habitat and Habits: Anadromous species that spawns in the Savannah River although sexually mature adults have been collected in Par Pond. It is not

52

I I'

60 known conclusively if the Par Pond population is a landlocked, breeding population, as the population is probably augmented each spring by passage of entrained larvae in cooling water during periods of reactor shutdown. Blue-back herring were observed spawning in the braided channels of Steel Creek delta in 1978 and suspected to be spawning in Par Pond in 1970. The eggs, which hatch in a single day, and early larval stages adhere to aquatic vege-tation in the narrow channels of clear water. Juveniles are attracted to the cooling water intake canals during the summer and are abundant there until November or December, feeding primarily on larval and pupal insects, copepods and cladocerans. Size: Spawning adults (N = 32) were 273-314 rom TL and 220-310 g in weight. Variable stages of gonadal development rendered length-weight regressions of adults unreliable, but for juvenile fish collected in autumn (N = 72, r = 0.99, maximum TL = 96 rom) In W= 2.820 (In TL) - 10.86.

References:

Burbidge

1974, Loesch and Lund 1977, Street 1969b, Street and Adams 1969, Adams and Street 1969, Giesy and Wiener 1977.

Alosa mediocris (Mitchill) - hickory shad Key Characters: Easily identified as a clupeid by the adipose eyelid and row of sawtoothed scales on the belly. Lower jaw projecting beyond upper jaw. Lower limb of gill arch has 18 to 23 gill rakers. SRP Distribution: Rare. Collected downstream of SRP on two occasions (ANSP 1953, 1955). This species does not ascend rivers as far upstream as its con-geners. Habitat and Habits: Anadromous species which spawns in the Savannah River but spawning as far upstream as the SRP has not been established.

F )" 61 Size: Maximum size about 435 mm and 1.4 kg.

References:

Street 1969a, Street and Adams 1969. Alosa sapidissima (Wilson) - American shad Key Characters: Cheek deeper than long. Peritoneum pale. One or more spots behind opercles. Lower jaw not projecting beyond upper jaw. SRP Distribution: Abundant. Commercially important species that is abundant during the spring and summer in the Savannah River. Habitat and Habits: Anadromous fish that spawn in the Savannah River. i Sportsmen fish for this species at the mouth of Steel Creek during the spring spawning run. Steel Creek is the only SRP stream that is known to be used for spawning; spawning activity is probably restricted to the lower, deeper reaches. Shad ascend the river in February as water temperatures attain 12-130 C. The adults persist in the river until June when water temperatures are about 20oC. Juveniles reared in the Savannah River may enter mouths of tributary streams to feed on planktonic organisms. Juveniles are attracted to the cooling water canals in late summer, feeding primarily on adult and pupal insects until December. They may be observed dimpling the water sur-face while feeding at dusk. Size: Maximum size is 3 kg. Four males from the SRP were 420-477 mm and 466-915 g; four females were 515-567 mm and 1735-2050 g. For juveniles collected in autumn the length-weight relationship (N = 85, r = 0.96, maximum TL = 126 mm) is In W= 2.812 (In TL) - 10.80.

References:

Leggett 1973, Godwin 1968, Vaughn 1967.

02 Dorosoma cepedianum (Lesueur) - gizzard shad Key Characters: Long anal fin with usually 29 to 35 rays. The last ray of dorsal fin is elongated into a long filament (Fig. 12). Gizzard shad have a longer anal fin and a noticeably more inferior mouth than threadfin shad, which they superficially resemble. SRP Distribution: Common. Gizzard shad are common in the Savannah River and swamp and the Par Pond system. Th~y have been collected from Lower Three

Runs, Four Mile Creek and Beaver Dam Creek.

The populations are resident year round. Habitat and Habits: Found in backwater areas and pools of creeks, large

rivers, lakes and swamps.

Feeds on phytoplankton and zooplankton. Spawns I f' tJ during April and early May. "j: II Size: Maximum length to 50 cm. SRP maximum is 49.4 cm, 803 g. Length-weight relationship (N = 79, r = 0.94) is In W = 3.489 (In TL) - 14.34. Dorosoma petenense (Gunther) - threadfin shad Key Characters: Last ray of dorsal fin elongated into a filament. Anal fin usually with 20 to 25 rays. This species can be confused with gizzard shad but threadfin shad have a shorter anal fin and a more terminal mouth. SRP Distribution: Uncommon. Collected occasionally in the Savannah River but unknown from any lake or stream on the SRP. Habitat and Habits: An intrO'duced species in the Savannah River which is vulnerable to low water temperatures and commonly impinged at the cooling water pumping stations when water temperatures drop below 100C. Threadfin shad feed on plankton. They are widely introduced as forage fish because of their small adult size. Size: Maximum length is 25 cm. SRP maximum is 145 mm; 27 g. Length-weight relationship (N = 88, r = 0.98) is In W= 3.117 (In TL) - 12.20. .c*****_*w-*

63 ORDER - SALMONIFORMES MUDMINNOW FAMILY - UMBRIDAE Mudminnows are inhabitants of streams and swamps. They are easily distinguished by their small size (up to 7.5 cm), posterior location of the dorsal fin, and non-protractile upper jaw. A single species, the eastern mudminnow, Umbra pygmaea, is found on the SRP. The body of this species has longitudinal streaks; a large vertical spot is found on the caudal peduncle. clearly visible. SRP Distribution: Uncommon. Mudminnows have been infrequently collected in the Savannah River, Upper Three Runs Creek, Pen Branch, Steel Creek, Lower Three Runs Creek. They also are present in Sarracenia Bay and Skinface Pond. Habitat and Habits: Found mainly in swampy areas and sluggish streams. Copepods and trichopteran larvae are the maj or food items of mudminnows. Size: SRP maximum is 113 mm, 18 g. Length-weight relationship (N =5, r = 0.99) is In W= 3.378 (In TL) - 13.10. Key Characters:

dorsal, caudal, Umbra pygmaea (DeKay) - eastern mudminnow A large vertical, dark spot on the caudal peduncle.

Rounded

anal, pelvic, and pectoral fins.

Longitudinal stripes are PIKE FAMILY - ESOCIDAE Members of the pike family have long cylindrically shaped bodies with duck-bill jaws and many large, sharp pointed teeth. The dorsal fin of eso-cids are typically posterior in location. All members of this family are predaceous, feeding primarily on fishes and other small organisms.

64 Two species of esocids are found on the SRP. The chain pickerel, Esox niger, is typically a lake form whereas the redfin pickerel, Esox americanus, is more commonly found in. the smaller streams and Carolina bays on the SRP. The two species are occasionally found together in the same habitat. Small juveniles of both species are found in the headwaters of SRP streams. Key to Species of Esox: 1. Total length less than 7.5 times snout length; subocular bar vertical; body with chain-like reticulations; fins not heavily colored Esox niger - chain pickerel page 6 Total length 8 or more times snout length; subocular bar inclined back-ward; no chain-like reticulations but white/yellow slanted bars on body; fins reddened Esox americanus - redfinpickerel page Esox americanus Gmelin - redfin pickerel 6* americanus is the accepted subspecies on the SRP. reddened. Snout short, 8.0 or more times into total length. Esox americanus ~l.: I I '1,1 II} ~> t'!

ilI, I

Key Characters: Subocular bar usually inclined backwards. Fins usually SRP Distribution: Abundant. Widely distributed on the Savannah River Plant; common to the Savannah River, abundant in small streams of all major creeks, Par Pond, and in many swamps and Carolina bays. Habitat and Habits: Backwaters of small streams in shallow water, concen-trated in areas having instream cover. Other fishes are the primary food item of subadults and

adults, whereas zooplankton are consumed by young.

Size: SRP maximum is 353 mm, 288 g. Length-weight relationship (N = 33; r = 0.98) is In W= 3.451 (In TL) - 14.23.

Reference:

Pflieger 1975.

65 Esox niger Lesueur - chain pickerel Key Characters: Snout long, less than 7.5 times in total length. Subocular bar vertical. Fins not colored. May ~be confused with redfin pickerel at small body sizes. SRP Distribution: Common. Present in all major creeks and the Savannah River. Chain pickerel are common in Par Pond and Skinface Pond. Habitat and Habits: Commonly found in deep pools of sluggish streams and around vegetation where they "stalk" their prey. Invertebrates are the principal food items of smaller pickerel << 10cm) whereas fish compose the i diet of larger animals. Size: Maximum weight of 4 kg. SRP maximum is 55 cm, 1.2 kg. Length-weight relationship (N = 36, r = 0.99) is In W= 3.103 (In TL) - 12.63. ORDER - CYPRINIFORMES MINNOW FAMILY - CYPRINIDAE The minnow family is one of the larger families of fishes on the SRP and the largest group of freshwater fishes in the United States, having more species than any other family. The closest relatives to the minnows are the suckers; minnows lack the sucker-like mouths and the pharyngeal teeth differ. Minnows generally have pharyngeal teeth in 1 or 2 rows (carp have 3) while suckers always have these teeth in a single row (Fig. 14). Pharyngeal teeth are an important characteristic distinguishing many species. Several of the cyprinids, however, are extremely difficult to key to species. Characters, such as pharyngeal tooth counts and number of fin rays are variable and may overlap but still are extremely useful characters to distinguish certain species.

66 Cyprinids are abundant in the riverine and lacustrine habitats on the SRP. McFarlane et a1. (1978) reported that 13 species have been collected from the Savannah River bordering the SRP; these vary in relative abundance from rare to abundant. In the tributary streams on the SRP, members of the family Cyprinidae have been collected from each of the five major creeks. 1. A Key to the Species of Cyprinidae Mouth with barbel; barbel may be small and may be in a terminal position on the maxillary (Fig. 16) 2 Mouth without barbel................................................... 5 !I IIII 'I

1 I

2. 3. 4. 5. Mouth with 2 barbels on each side of the upper jaw (Fig. 16C); pharyngeal teeth in 3 rows; strong serrated spine at origin of dorsal and anal fins; dorsal fin with more than 11 soft fin rays ..........................................Cyprinus carpio - carp page Mouth with 1 barbel on each side of the upper jaw; pharyngeal teeth in 1 or 2 rows; spines absent, dorsal fin with fewer than 11 soft fin rays Barbel not terminal but set below the maxilla and some distance forward from its posterior end (Fig. 16A); dorsal fin with a dark spot at origin; origin of dorsal fin behind pelvic fins Semotilus atromaculatus - creek chub page Barbel terminal on maxillary (Fig. 16B); dorsal fin without a dark spot at origin; origin of dorsal fin above or before pelvic fins Mouth horizontal and inferior; snout extending beyond upper lip; eye longer than upper jaw; pharyngeal teeth 1-4-4-1; body with silvery stripe; dark broken outline of lateral line; breast without scales; melanophores on base of anal fin Hybopsis rubrifrons - rosyface chub page Mouth not horizontal and inferior; snout rounded, not extending beyond upper lip; pharyngeal teeth 4 - 4; may have dark lateral stripe .......................... Nocomis leptocephalus - bluehead chub page Belly behind pelvic fins with a sharp scaleless keel (Fig. 17); adults silvery gold color; lateral line deeply down-curving; anal fin falcate and long, with 14-18 principal rays .........................Notemigonus crysoleucas - golden shiner page 71 3 78 4 72 73 72 Belly without a sharp scaleless keel; lateral line not deeply down-curving; anal fin shorter with fewer rays............................ 6

67 A. Figure 16. Barbel location (arrows) in creek chub, Semotilus atromaculatus, (A), bluehead chub, Nocomis leptocephalus, (B), and carp, Cyprinus carpio, (C) (after Blair et al. 1968) (See Appendix I).

68 Figure 17. Location of the keel in golden shiner, Notemigonus crysoleucas. Figure 18. Location of pelvic fin relative to dorsal fin or~g~n in (A) ironcolor shiner, Notropis chalybaeus, (B) and dusky shiner, N. cummingsae (after Eddy 1957; see Appendix I).

69 6. Mouth nearly horizontal and inferior, the maxillary ending below the posterior portion of the nostril; snout extending beyond lower jaw; silvery color with dark back; intestine long with several coils; teeth 4 4; peritoneum very black ,.. Hybognathus nuchalis - silvery minnow page 71 Mouth horizontal or oblique; snout rarely extending beyond lower jaw; color silvery with a dark lateral stripe; teeth usually 1,4-4,1 or 2,4-4,2 but may be 5-5; intestine with only 1 anterior loop; peri-toneum silvery or black genus Notropis 7 7. Pharyngeal teeth in single row, either 4-4 or 5-5 8 Pharyngeal teeth in two rows, either 1,4-4,1 or 2,4-4,2.............. 11 8. Pharyngeal teeth 5-5, strongly hooked and serrated; mouth very small and sharply oblique; dorsal rays typically 9; anal rays 8; maxilla extending only about ~ distance to anterior of eye ...........................Notropis emiliae - pugnose minnow page 74 Pharyngeal teeth 4-4, not strongly hooked and serrated; mouth large and not sharply oblique; maxilla extending to greater than ~ distance to anterior of eye....................................... 9 9. Caudal spot round, large and conspicuous with small dark triangles occurring at upper and lower edge of caudal base; lateral stripe ex-tending.to eye; lateral line incomplete (ending before caudal peduncle); anal rays usually 8; pharyngeal teeth 4-4; anal fin slightly falcate; mouth small Notropis maculatus - taillight shiner page 77 Caudal spot small and inconspicuous; lateral stripe extending from below dorsal fin to caudal base; lateral line complete; anal rays 7 or*8; anal fins not falcate; mouth larger.......................... 10 10. Anal rays usually 8; pharyngeal teeth 4-4; interradial pigment slight, anterior to the 6th ray of dorsal; lower sides of body and belly with little or no pigment (especially on caudal peduncle) ex-cept bordering anal base where it is intense; snout longer and point-ed; black lateral stripe starting below dorsal fin extending to base of caudal fin; median fins light tipped ~ ............................Notropis niveus - whitefin shiner page 77

70 Anal rays 7; pharyngeal teeth 4-4; pigment on first few rays of dor-sal fin; snout long but not pointed; lower jaw included; snout ex-tending beyond lower jaw; dorsal origin over pelvic fins; broad dark lateral stripe starting below dorsal fin ending in a faint caudal spot Notropis leedsi - bannerfin shiner page 76 11. Anal rays usually 7; lateral stripe darker anteriorly; snout pointed; pigment around base of anal fin that extends to caudal fin as 2 or 3 broken stripes; pharyngeal teeth 2,4-4,2 ......... ~ Notropis petersoni - coastal shiner page 77 Anal rays 8 or more; lateral stripe variable from wide and intensely dark to narrow and silvery; pigment not extending to caudal fin as 2 or 3 broken stripes; pharyngeal teeth 2,4-4,2 or 1,4-4,1 12 12. Pelvic fins under origin of dorsal fin (Fig. 18A) 13 Pelvic fins anterior to origin of dorsal fins (Fig. 18B) 14 13. Pharyngeal teeth usually 1,4-4,1; anal rays usually 8; scales behind anal fin not pigmented; caudal spot may be present; lateral stripe narrow and silvery, with width less than diameter of eye; eye large; snout blunt; dorsal origin anterior to pelvic fins Notropis hudsonius - spottail shiner page 75 Pharyngeal teeth usually 2,4-4,2 (rarely 2,4-4,1); anal rays usually 8; dark lateral stripe extends through eye and snout; mouth very oblique and small, about 2/3 snout length; anal fin deeply falcate; caudal fin deeply forked; dorsal fin large; anterior ray of depressed dorsal greatly exceeding the posterior rays by 2-3 scale lengths on midline; vertical fins and sides above lateral stripe orange in breeding males; inner portion of lower jaw heavily pigmented; eye larger than snout; lateral line complete .......................Notropis chalybaeus - ironcolor shiner page 73 14. Anal rays usually 8; pharyngeal teeth 2,4-4,2; lateral stripe strong, almost equally developed throughout length and on caudal fin; opercle and preopercle heavily pigmented on upper half, devoid of pigment on lower half; no pigmentation from anal to caudal fin; eye small, diam-eter less than snout length; breeding males entirely red with yellow fins and white cap on head Notropis lutipinnis - yellowfin shiner page 76 Anal rays 9 or more; pharyngeal teeth 2,4-4,2 or 1,4-4,2; color of breeding males not as above 15 15. Anal rays usually 9 (10-11 is common); pharyngeal teeth 2,4-4,2; dor-sal fin with a conspicuous horizontal black blotch; base of caudal fin marked with white or with 2 rosy spots (in fresh specimens) at base; lateral stripe wide and silvery; caudal spot smaller than eye Notropis hypselopterus - sailfin shiner page 75 Anal rays 10-11; pharyngeal teeth 1,4-4,1; dorsal fin without a con-spicuous horizontal black blotch; lateral stripe wide, extending Q

71 around tip of snout; mouth small, extending to front of eye; eye large with diameter equal to or longer than snout Notropis cummingsae - dusky shiner page 74 Cyprinus carpio Linnaeus - carp Key Characters: Mouth subterminal with 2 barbels on each side of the upper jaw (Fig. 16C). Dorsal and anal fins with serrated spines. SRP Distribution: An introduced species uncommon to the SRP. Carp inhabit the Savannah River and swamp but rarely ascend streams. They are unknown from any of the reservoirs, but were captured by Humphries (1965) in Upper ) Three Runs Creek. Habitat and Habits: Carp are found in sluggish sections of rivers usually over mud bottoms. Widely introduced into the U. S. from Europe because of esteemed food value. Carp feed primarily on benthos, plant materials, and plankton. They frequently roll and break the surface of the water with their backs. On the SRP, carp are most readily captured with trammel nets and by electrofishing in the cooling intake canals. Size: The largest carp caught in North America was 27 kg. SRP maximum is 820 mm, 7.2 kg. Hybognathus nuchalis Agassiz - siivery minnow Key Characters: Large scales. Snout extends beyond lower jaw. Pharyngeal teeth 4-4 and flattened. Dorsal fin origin anterior to that of pelvic fins. Anal rays 8. SRP Distribution: Abundant in the Savannah River and also present in Lower Three Runs Creek and reported from Four Mile Creek (Freeman 1954).

72 Habitat and Habits: Found mainly in large river systems and occasionally in smaller streams. Majority of fish collected on SRP were from the Savannah River (McFarlane et a1. 1978). Size: Maximum size about 12 cm. . Hybopsis rubrifrons (Jordan) - rosyface chub Key Characters: Mouth inferior. Eye longer than upper jaw. Lower jaw included. Pharyngeal teeth 1,4-4,1. Anal rays 8. Black to silvery lateral stripe. Small barbels at end of maxillary. SRP Distribution: Uncommon. A few specimens have been collected in the Savannah River and a small tributary of Upper Three Runs. Habitat and Habits: Larger rivers and their tributaries. Size: Maximum length is 10 cm. SRP maximum is 7.6 rom, 3.9 g. Length-weight relationship (N = 28, r = 0.97) is 1n W= 3.055 (In TL) - 11.89. Notemigonus cryso1eucas (Mitchi11) - golden shiner Key Characters: A deep-bodied minnow with a strongly up-turned but very small mouth. Lateral line complete and strongly decurved. A fleshy, scale-less keel present along midline of belly from anus to pelvic fin bases (Fig. 17). SRP Distribution: Common in all creeks on the SRP, except absent from the Sa1kehatchie River. Uncommon in the Savannah River. Present in the Par Pond system, Skinface Pond, and Twin Lakes. Habitat and Habits: Found in backwaters or slow moving sections of creeks, usually associated with vegetation. Often found schooling near the surface. Feeds on plant and animal matter. Spawns over algae or submerged aquatic

73 o macrophytes when water temperatures warm to about 22 C. May spawn in associ-ation with sunfishes. Size: Maximum length 20 em. Nocomis leptocephalus (Girard) - bluehead chub Synonyms: Hybopsis bellicus (Freeman 1954), Nocomis bellicus (ANSP 1953), Hybopsis leptocephala (Blair et al. 1968). Key Characters: Terminal barbel on maxillary (Fig. 16B). Mouth terminal. Snout rounded. Pharyngeal teeth 4-4; anal rays usually 7. / SRP Distribution: Common. Found in small tributaries of all creeks.except the Salkehatchie River; rare in the Savannah River. Habitat and Habits: A chub widely distributed in SRP streams; generally associated with stream cover. Individuals of this species are active stream inhabitants and can be seen darting from one area to another. Size: SRP maximum 13.6 em, 24 g. Notropis chalybaeus (Cope) - ironcolor shiner Synonyms: Hydrophlox chalybaeus (Fowler 1935). Key Characters: Dark lateral stripe. Mouth small, about 2/3 snout length. Dorsal fin origin over pelvic fin (Fig. 18A). Long anterior rays of dorsal fin (extending 2-3 scales along midline). Pharyngeal teeth 2,4-4,2. Anal rays 8. Inner portion of lower jaw heavily pigmented. SRP Distribution: Common. Found in Upper Three Runs Creek, Pen Branch, and Lower Three Runs Creek. Freeman (1954) also collected it in Four Mile Creek. Rare in the Savannah River. Habitat and Habits: Strongly schooling minnow found in smaller tributaries and larger creeks of medium velocity with sandy bottoms. Spawning occurs

74 over sand where eggs adhere to the bottom. Invertebrate organisms are the primary food. Size: Maximum length is 8 em. Notropis cummingsae Myers - dusky shiner Key Characters: Breast scaly. Pelvic insertion anterior to dorsal fin (Fig. 18B). Wide lateral stripe extends around snout. Eye large, equal to or larger than snout. Pharyngeal teeth 1,4-4,1. Anal rays 10-11. SRP Distribution: Common. Found in all major creeks but rare in the Savan-nah River. Not collected from Pen Branch recently but collected there by Freeman (1954) prior to plant operations. Habitat and Habits: Found over sandy bottom streams having a perceptible current. The most abundant schooling minnow of second-and third-order SRP streams; found only in lower reaches of first-order streams. Size: Maximum length 75 mm. SRP maximum 49

rom, 0.79 g.

Length-weight relationship (N =31, r =0.96) is In W=3.172 (In TL) - 12.52.

References:

Hubbs and Raney 1951, McFarlane et al. 1976, Smith-Vaniz 1968. Notropis emiliae (Hay) - pugnose minnow Synonyms: Opsopoeodus emiliae (Blair et al. 1968). Key Characters: Dorsal fin in adult males has dark-light-dark pigmentation pattern. Snout without concentration of pigment. Breast scaleless. Dorsal rays 9. Anal rays 8. Mouth very small and nearly vertically oblique. Pharyngeal teeth 5-5, hooked and serrated. SRP Distribution: Rare. Not collected from any creeks on the SRP and rarely captured in the Savannah River. Habitat and Habits: Large sluggish rivers or back water areas. Size: Maximum length 8 em. SRP maximum 4.7 em, 0.9 g.

75 Notropis hudsonius (Clinton) - spottail shiner Key Characters: Large minnow with silvery stripe; width of stripe smaller than diameter of eye. Eye large. Snout blunt and upper jaw included. Pharyngeal teeth usually 1,4-4,1. Anal rays usually 8. Dorsal origin an-terior to pelvic fins. SRP Distribution: Abundant in the Savannah River; uncommon in the lower reaches of Upper Three Runs and Steel Creek. Habitat and Habits: A shiner found almost exclusively in large creeks and rivers with moderate to slow current. Feeds primarily on invertebrates but i fish eggs and juvenile fishes also have been found in the diet. Size: Maximum length 15 cm. SRP maximum 12.4 cm, 17.5 g. Length-weight relationship (N = 100, r = 0.99) is In W= 3.085 (In TL) - 12.07.

Reference:

Wells and House 1974. Notropis hypselopterus (Gunther) - sailfin shiner Synonyms: Notropis stonei (Fowler 1920); Notropis hypselopterus stonei is the subspecies on the SRP. Key Characters: Conspicuous horizontal black blotch on dorsal fin. Lateral stripe dark and wider than the eye. Pelvic fins anterior to dorsal fin origin (Fig. 18B). Breast scaly. SRP Distribution: Uncommon. Collected in small numbers from Lower Three Runs

Creek, Four Mile Creek, Upper Three Runs, and the Salkehatchie River.

Not collected in the Savannah River adjacent to the SRP. Habitat and Habits: Flowing streams with perceptible current and having sandy or muddy bottom types. Size: Maximum length 7 cm. SRP maximum 4.5 cm, 0.5 g. Length-weight re-lationship (N = 83, r = 0.93) is ln W=3.431 (In TL) - 13.54.

Reference:

Fowler 1920.

76 Notropis leedsi Fowler - bannerfin shiner Key Characters: Breast scaleless. Pigment on first few rays of dorsal fin. Lower jaw included. Broad lateral stripe below dorsal fin terminates as faint caudal spot. Pharyngeal teeth 4-4. Anal rays 8. SRP Distribution: Uncommon in the Savannah River; not found in major tribu-tary streams. Habitat and Habits: Large rivers. Size: SRP maximum 8 em, 5.7 g. Length-weight relationship (N = 25, r = 0.98) is In W= 3.132 (In TL) - 12.08.

Reference:

Fowler 1942. Notropis lutipinnis (Jordan and Brayton} - yellowfin shiner Synonyms: Hydrophlox lutipinnis (Jordan and Brayton 1878) Key Characters: Breast scaleless. Dark lateral stripe from caudal fin to snout. Pharyngeal teeth 2,4-4,2. Anal rays 8. Anal to caudal fin without pigment. Fins yellow. Red with white fins and white cap on head during breeding season. SRP Distribution: Abundant. The most abundant shiner in tributary streams on the SRP and the dominant minnow of first-order tributaries. Not found in the Savannah River. Habitat and Habits: Small streams over sandy, gravel bottom types. Turns scarlet during the spawning season. Spawns over piles of fine to coarse gravel in shallow riffles. Size: Maximum size is about 10 to 12 cm. SRP maximum is 7.4 em, 3.62 g. Length-weight relationship (N = 78, r = 0.96) is In W = 3.108 (In TL) 12.18.

Reference:

McFarlane et al. 1976.

77 Notropis maculatus (Hay) - taillight shiner Key Characters: Large, distinct caudal spot. Dark lateral stripe extending to eye. Tip of snout whitened. Anal fin slightly falcate. Mouth small. Lateral line incomplete. SRP Distribution: Uncommon. Collected from all creeks except Pen Branch and the Salkehatchie River; rare in the Savannah River. Habitat and Habits: Slow moving shoreline areas of streams having low gradi-ent over muddy bottom. Size: Maximum length 7 em. SRP maximum 6.3 em, 2.0 g. Length-weight re-i lationship (N = 6, r = 0.97) is In W= 3.795 (In TL) - 14.87. Notropis niveus (Cope) - whitefin shiner Key Characters: Pigment on posterior dorsal rays. Breast without scales. Dark lateral stripe extending below dorsal fin to base of caudal fin. Jaws equal; snout long and pointed. Tip of median fins light in color. Pharyn-geal teeth 4-4. Anal rays usually 8. SRP Distribution: Rare. A few were collected from Lower Three Runs Creek by Freeman (1958) after the advent of SRP operations but none have been seen since. Uncommon in the Savannah River. Habitat and Habits: Large rivers. Size: SRP maximum 12.7 em, 19.6 g. Length-weight relationship (N = 19, r = 0.96) is In W= 3.611 (In TL) - 14.36. Notropis petersoni Fowler - coastal shiner Key Characters: Pointed snout. Breast scaleless. Dorsal fin origin over pelvic fins. Pharyngeal teeth 2,4-4,2. Anal rays usually 7. Concentration of pigment at anal base extending to caudal fin as 2-3 broken lines. Lateral line delimited by melanophores.

78 SRP Distribution: Common. The only Notropis found in Par Pond. Commonly caught in all creeks except Pen Branch and the Salkehatchie River.

Also, found at creek mouths; regularly caught in low numbers in the Savannah River and Skinface Pond.

Habitat and Habits: Lakes and slower flowing stretches of streams. Usually found over sandy bottoms. In Steel Creek it is most common in deep pools. Size: Maximum length usually less than 8 cm. SRP maximum 7.6 cm, 3.5 g. Length-weight relationship (N = 55, r = 0.98) is In W = 3.132 (In TL) 12.06. Semotilus atromaculatus (Mitchill) - creek chub Key Characters: Mouth with non-terminal barbel below maxilla (Fig. 16A). Dorsal fin with a large dark spot at base. Dorsal fin origin behind pelvic fins. SRP Distribution: In small tributaries of all creeks except the Salkehatchie River. Not found in the Savannah River. Habitat and* Habits: Found under cover in small streams having moderate velocity and sandy bottoms. Fast swimmers which rapidly dart from one cover area to another. Creek chubs pile gravel for spawning in the late spring and summer. Food is aquatic insects and fish. Size: Maximum length about 25 cm. SRP maximum 115 mm; 18 g. Length-weight relationship (N = 41, r = 0.96) is In W= 3.417 (In TL) - 13.20.

Reference:

McFarlane et al. 1976. SUCKER FAMILY - CATOSTOMIDAE Members of the Catostomidae are soft-rayed fishes that have sucker-like mouths (Fig. 13). Most of the fishes in this family have thick lips that are

i 79 generally covered by folds of skin. Suckers are closely related to minnows but differ by having more than 10 dorsal rays (minnows have 10 or fewer dorsal rays) and the last pharyngeal arch contains a single row of comb-like teeth (Fig. 14A). Minnows either have more than one row of pharyngeal teeth or one row with five or fewer teeth. Suckers are abundant in various habitats on the SRP. Some are found in small, higher gradient streams while other species inhabit the larger creeks, lakes, the Savannah River, and even Carolina bays. Key to the Species of Catostomidae 1. Dorsal fin with 25 to 40 rays; anterior dorsal rays nearly three times as long as posterior dorsal rays ................................ Carpiodes cyprinus - quillback page 80 Dorsal fin with 10 to 18 rays; anterior dorsal rays not more than twice as long as posterior dorsal rays................................. 2 2. Top of head concave between eyes; eye behind middle of head; body with 4-6 conspicuous dark cross-bars (dorsal saddles) .....................Hypentelium nigricans - northern hogsucker page 81 Top of head not concave between eyes; eye nearly centered in head; body without cross-bars................................................ 3 3. Dorsal fin rays usually 14 or.15; rear margin of lower lip forming an acute angle (Fig. 13A); 12 scales around caudal peduncle ........................ Moxostoma anisurum - silver redhorse page 82 Dorsal fin rays usually 12 or 13; rear margin of lower lip nearly straight or forming a slight angle..................................... 4 4. Scales on sides with dark spots at bases, forming stripes; snout ex-tending well beyond upper lip (Fig. 13B); lateral line nearly complete (terminates near anal fin).................................*........... ..........................* Minytrema melanops - spotted sucker page 82 Scales on sides without dark spots at bases but may appear as a single dark stripe; snout not extending beyond upper lip; lateral line absent. 5 5. Longitudinal scale rows 39-45; head small (3.5 - 4.2 in standard length); dorsal fin rays usually 10 (rarely 11) ............................Erimyzon oblongus - creek chubsucker page 80

80 Longitudinal scale rows 34-38; head large (3.2 - 3.8 in standard length); dorsal fin rays usually 11 or 12 .............................Erimyzon sucetta - lake chubsucker page 81 Carpiodes cyprinus (Lesueur) - quillback Key Characters: Dorsal fin long with 25 to 40 rays. Anterior dorsal rays nearly three times the length of the posterior dorsal rays. Body heavy with large scales. SRP Distribution: Rare. QUillback have not been collected in any creeks on the SRP; they are considered rare in adjacent Savannah River waters. Habitat and Habits: An inhabitant of large rivers and large impoundments. Generally found over bottom types with organic matter. Food is

diatoms, aquatic insects and algae.

Size: Maximum size about 2.5 kg. Erimyzon oblongus (Mitchill) - creek chubsucker Key Characters: Lateral line absent. Young with black longitudinal stripe. Scales

small, 39-45 longitudinal scale rows.

sucetta. Fins amber in young juveniles. Easily confused with E. SRP Distribution: Common. Found in tributaries of all major creeks on SRP. Rare in the Savannah River. Habitat and Habits: Found in smaller streams with low to moderate gradient. Not found in any lakes or swamps. Aquatic insects, microcrustaceans, and algae constitute the diet of creek chubsuckers. Size: Maximum length about 25 cm. Length-weight relationship (N = 85, r = 0.99) is In W= 3.34 (In TL) - 12.56.

81 Erimyzon sucetta (Lacepede) - lake chubsucker Key. Characters: Lateral line absent. Young with black longitudinal stripe, fins reddened in young. Scales large, longitudinal scales 34-38. SRP Distribution: Common. A few lake chubsuckers have been collected from all creeks on the SRP. They are present in Par Pond and other SRP ponds but rare in the Savannah River. Habitat and Habits: Chubsuckers are found in standing waters with organic matter on the bottom and are generally located around cover. They spawn in the spring in streams and along lake shorelines. Lake chubsuckers feed i primarily on microcrustaceans and thironomid larvae. These are considered important forage fish for large fish predators. Size: Maximum length about 25 em. Length-weight relationship (N = 27, r = 0.99) is In W= 3.34 (In TL) - 13.00. Hypentelium nigricans (Lesueur) - northern hogsucker Key Characters: A large bony head with eyes set closer to gill cover than to tip of snout. Head concave between eyes. Four to six cross-bars that extend forward onto sides. SRP Distribution: Common: Found in Upper Three Runs Creek, Pen Branch and Steel Creek. Not collected from any lentic waters on SRP. Habitat and Habits: Found in streams with clean gravel substrate having perceptible flow. Usually found in riffles. Darts rapidly from one area to the next. Overturns rocks when feeding. Spring spawner over fine substrate. Size: Maximum size about 42 em.

82 Moxostoma anisurum (Rafinesque) - silver redhorse Key Characters: Protractile premaxillary. Lateral line complete. Air bladder with three sections. Caudal fin rounded and slightly forked. Dorsal fin rounded. Scales large, 12 around caudal peduncle. Transverse creases in plicae. Rear margin of lower lip forming an acute angle (Fig. 13A). SRP Distribution: Common in deeper pools at mouths of Lower Three Runs Creek and Upper Three Runs Creek. Uncommon in the Savannah River adjacent to the SRP. Habitat and Habits: Deeper slow flowing waters that are clear. Found in open water. Spa~n i~ ~pringtime at about 13.5 C. Food consists mainly of ephemeropteran, triehopteran, and dipteran larvae. Size: Maximum length over 60 cm. SRP maximum 49.8 em, 1341 g. Length-weight relationship (N = 41, r = 0.99) is In W= 2.96 (In TL) - 11.14.

Reference:

Jenkins 1970.

83 ORDER SILURIFORMES CATFISH FAMILY - ICTALURIDAE Ictalurids are easily distinguished by their broad flat heads, sharp pectoral and dorsal spines, scaleless bodies '. and barbels on the upper and lower jaws; Three well-known common names are used for fishes in this family: catfishes, bullheads, and madtoms. Members of Ictaluridae are common in a wide range of waters on the SRP from the smaller t~ibutary streams to the Savannah River. Ictalurids are not I often seen by untrained observers because of their clandestine habits--hiding under logs, stones, or other debris and in undercut banks. Madtoms should be handled carefully as their poisonous pectoral spines can inflict a painful sting. A Key to the Species of Ictaluridae 1. 2. Caudal fin forked Caudal fin rounded or square, not forked Anal fin rays 18-26 (x.= 23); tail lobes not pointed, upper lobe longer than lower lobe; body without small dark spots; head flattened .............................. Ictalurus catus - white catfish page 2 3 86 Anal fin rays 24-29; tail lobes pointed, upper lobe about equal to lower lobe; body with small irregular spots; head rounded in young specimens; somewhat flattened in larger specimens ........................ Ictalurus punctatus - channel catfish page 88 3. Adipose fin free at its posterior end (Fig. 19A) 4 Adipose fin adnate to back (Fig. 19B).................................. 8 4. Anal fin rays less than 16; band of teeth in upper jaw with backward lateral extensions (Fig. 19C); caudal fin truncated; head flattened.... ........................Pylodictis olivaris - flathead catfish page 90 Anal fin having 16 or more rays; band of teeth in upper jaw without backward lateral extensions (Fig. 19D); head not flattened............. 5

84 u I m Figure 19. Adipose fin type (A - Ictalurus punctatus; B - Noturus sp.) and appearance of premaxil-lary teeth (C - Pylodictis olivaris; D - Ictalurus sp.) in members of the family Icta-luridae (after Forbes and Richardson 1920; see Appendix I).

85 5. Chin barbels white or pink but never dark (barbels on larger forms may be grayish); anal fin rays 25 to 28; anterior rays of anal fin only slightly longer than posterior rays ........................ Ictalurus natalis - yellow bullhead page 86 Chin barbels with melanophores, usually black (occasionally whitish); anal fin rays 25 or fewer; anterior rays of anal fin distinctly longer than posterior rays................................................. 6 6. Body mottled; mouth terminal or nearly so; pectoral spines with many large serrae on posterior edge; anal fin rays 22 to 25; no dark streak across base of dorsal fin ......................... Ictalurus nebulosus - brown bullhead page 87 Body not mottled; mouth subterminal to strongly inferior; pectoral spines with small serrae; dark streak across base of dorsal fin (may be obscured by tissue in larger forms)............................... 7 7. Pectoral spines with serrae on anterior and (number of anal rays minus number of gill rakers) posterior edge; anal fin rays 19-24; gill rakers 11-14; character index 8-13 (rarely 6 or 7); mouth sub-terminal to moderately inferior ......................... Ictalurus brunneus - snail bullhead page 85 Pectoral spines with serrae on posterior edge; anal fin rays 16-22; gill rakers 12-17; character index 1-7 (rarely 8 or 9); mouth moderately to strongly inferior ................... Ictalurus platycephalus - flat bullhead page 87 8. Pectoral spines without serrae on posterior edges 9 Pectoral spines with serrae on posterior edges (both left and right spines need to be examined); serrae long and sharp; body long and tapering Noturus insignis - margined madtom page 89 9. Lower jaw shorter than upper (included); body and fins with numerous chromatophores (spotting); pectoral spine short and slender, about 1/3 length of head; no thin lateral stripe ......................Noturus leptacanthus - speckled madtom page 89 Jaws equal; body and fins without spotting; pectoral spine long and

stout, about

~ length of head ............................Noturus gyrinus - tadpole madtom page 88 Ictalurus brunneus (Jordan) - snail bullhead Key Characters: Caudal fin rounded. Adipose fin free, its posterior end not attached. Mouth subterminal to moderately inferior. Pectoral spines with small serrae on anterior and posterior surfaces. Anal rays 19-24. Gill

86 rakers 11-14. Character index 8-13 (rarely 6 or 7). Commonly confused with !. platycephalus. SRP Distribution: Rare. Specimens known from the Savannah River and Steel Creek. Habitat and Habits: Larger creeks and rivers supporting snail populations. Diet believed to consist primarily of snails. Size: Maximum length about 28 cm. SRP maximum 28 cm, 240 g. Length-weight relationship (N = 7, r = 0.99) is ln W= 2.77 (In TL) - 10.08. I.",

Reference:

Yerger and Relyea 1968. Ictalurus catus (Linnaeus) - white catfish Key Characters: Anal rays 18-26. Caudal fin not deeply forked. Head flat-tened. Body without small dark spots. Tail lobes blunt not pointed. Often confused with !. punctatus. SRP Distribution: Rare in the Savannah River. Collected in Steel Creek, Upper Three Runs

Creek, and Lower Three Runs Creek, and probably occurs in lower sections of all major creeks.

Some specimens of I. punctatus in ear-lier surveys were misidentified as I. catus. Habitat and Habits: Found in waters of intermediate velocity and having firm bottom types. Feed predominately on fish but also on vegetative material and aquatic insects. Size: Maximum length about 120 cm. SRP maximum 64 cm, 3690 g. Length-weight relationship (N = 6, r =.99) is ln W= 3.213 (In TL) - 12.62. Ictalurus natalis (~esueur) - yellow bullhead Key Characters: Rounded caudal fins. Anal fin rays 25 to 28; anterior rays about same length as posterior rays. Chin barbels white or pink in young becoming gradually darker. Mouth terminal. Belly usually yellowish. May be

j 87 confused with 1. platycephalus or 1.

brunneus, but juveniles lack melano-phores in chin barbels.

SRP Distribution: Abundant. Found in all creeks on the SRP. Rare in the Savannah River. Abundant in lakes and ponds on the SRP. Habitat and Habits: Sluggish waters; clear or turbid. Commonly associated with instream cover and undercut banks in streams. Feeds on aquatic inverte-brates and some fish. Size: Maximum length about 55 cm. SRP maximum 31.0 cm, 420 g. Length-weight relationship (N = 10, r = 0.99) is In W = 3.112 (In TL) 11.85. Ictalurus nebulosus (Lesueur) - brown bullhead Key Characters: Mottled body. Mouth terminal. Pectoral spines with long, sharp serrae on posterior edge. Anal fin rays 22 to 25. Perhaps the most frequently misidentified catfish on the SRP and likely much rarer than re-ported. SRP Distribution: Uncommon. Collected in Upper Three Runs, Four Mile, Pen Branch and Steel Creeks. Also reported by previous investigators in Lower Three Runs Creek. Rare in the Savannah River adjacent to the SRP. Also found in several farm ponds and the Par Pond system. Habitat and Habits: Quiet areas in streams and ponds having a muddy bottom type. Spawn in spring, utilizing a nest; males provide protection. Zoo-plankton, plants, aquatic invertebrates, and fish are eaten. Size: Maximum length about 55 cm. Ictalurus platycephalus (Girard) - flat bullhead Key Characters: Fins edged with black. Pectoral spines with serrae on pos-terior edge. Anal fin rays 16-22. Gill rakers 12-17. Character index 1-7 (rarely 8 or 9). Mouth inferior. Commonly confused with I. brunneus.

r \\ i 88 SRP Distributi9n: Common. Collected in all creeks except the Salkehatchie River. Abundant in the lower sections of creeks and common in the Savannah River. Collected in Par Pond and probably found in farm ponds. Habitat and Habits: Slow moving

streams, backwater areas and pools with muddy bottom types.

Benthic organisms are consumed for food. Size: SRP maximum 47 em, 555 g. Length-weight relationship (N = 50, r = 0.99) is In W= 3.22 (In TL) - 12.66.

Reference:

Yerger and Relyea 1968. Ictalurus punctatus (Rafinesque) - channel catfish II,. Key Characters: Deeply forked tail. Small irregular dark spots on body (especially in young). Head rounded in young, somewhat flattened in larger specimens. Commonly confused with I. catus. SRP Distribution: A common, introduced species commercially harvested in the Savannah River. Common in the lower reaches of Upper Three Runs, less common in other streams. Occasionally collected in Par Pond. Habitat and Habits: Prefer rapidly moving water at head end of pools and be-low dams. Feed on aquatic insects, shellfish and fishes. Size: Maximum size about 10 kg. SRP maximum 53.0 em, 1630 g. Length-weight relationship (N =66, r = 0.99) is In W=3.135 (In TL) - 12.50.

Reference:

Humphries 1965. Noturus gyrinus (Mitchill) - tadpole madtom Key Characters: Adipose fin adnate to back (Fig. 19B). No serrae on pec-toral spines; pectoral spine about 2/3 length of fin. Jaws equal in length. Yellowish brown above, pale below. Thin lateral stripe present.

1 I I! SRP Distribution: Common. 89 Distributed in smaller tributaries and major creeks; not collected in Pen Branch. Not collected. from the Salkehatchie River by the authors, although Freeman (1954) reported them there; found in the Par Pond system. Rare in the Savannah River. Habitat and Habits: Sheltered areas beneath streambanks and between rocks in streams experiencing high velocities. Also found in ponds and backwater areas of streams. Feeds on entomostracans and chironomids. Size: Maximum length about 15 em. SRP maximum 9 em, 4.95 g. Length-weight relationship (N = 11, r = 0.99) is In W= 2.97 (In TL) - 11.70. Noturus insignis (Richardson) - margined madtom Synonyms: Noturus marginatus; Pimelodus insignis (Richardson 1836) Key Characters: Adipose fin adnate to back (Fig. 19B). Pectoral fin long, posterior edge with, sharp serrae. Body long and tapering to caudal fin. SRP Distribution: Uncommon. Collected from Upper Three Runs, Pen Branch and Steel Creeks. Also taken in an earlier survey ip Lower Three Runs Creek. Not found in the Savannah River. Habitat and Habits: Creeks with low gradient having soft bottoms. Feed on insects and fish. Size: Maximum length about 30 em.

Reference:

Hubbs and Raney 1944. Noturus leptacanthus (Jordan) - speckled madtom Key Characters: Adipose fin adnate to back (Fig. 19B). Pectoral spine with-out serrae and less than ~ length of fin. Body long and speckled. Fins dark. Lower jaw included.

90 SRP Distribution: Abundant. Collected from all major creeks but the Salke-hatchie River. Collected in the Savannah River but considered rare. Habitat and Habits: Small to large creeks with low to medium gradient. Feeds on aquatic invertebrates and fish. Frequently associated with algal mats. Size: Maximum length about 8 cm. SRP maximum 6.3 cm, 2.25 g. Length-weight relationship (N = 40, r = 0.98) is In W= 3.01 (In TL) - 11.78. Pylodictis olivaris (Rafinesque) - flathead catfish Key Characters: Truncated caudal fin. Band of teeth in upper jaw with backward lateral extensions (Fig. 19C). Anal fin rays fewer than 16. SRP Distribution: A rare, introduced species reported from the Savannah River (ANSP 1955) downstream of the SRP and from Par Pond (Clugston 1973a). Habitat and Habits: Large impoundments and large rivers. Found below dams behind cover; feed in riffles. Adults generally remain unde~ cover. Juve-niles feed on aquatic insects; adults eat predominately fish. Size: Maximum size about 45 kg. ORDER - PERCOPSIFORMES CAVEFISH FAMILY - AMBLYOPSIDAE Members of the cavefish family are diverse. Some cavefish do not have eyes, although functional eyes occur in the only SRP species, the swampfish (Chologaster cornuta). All six species in this family are confined to east-ern North America; all but C. cornuta are found in caves. This species has a flat naked head and no pelvic fins. The anus in adults is located in the jugular position.

91 Chologaster cornuta Agassiz - swampfish. Key Characters: Head flattened. Rounded dorsal fin directly above anal fin. Pelvic fins absent. Caudal fin and dorsal surface of body dark. Anus jugu-lar in adults (Fig. 15A). Dark vertical bands on caudal fin. SRP Distribution: Rare. Collected from Lower Three Runs

Creek, the Salkehatchie River, and the Savannah River.

Previously collected from Upper Three Runs. Probably occurs in all creek systems. Habitat and Habits:

Swamps, backwater areas of larger rivers and springs with detritus substrate.

j Size: Maximum length about 5 em. PIRATE PERCH FAMILY-APHREDODERIDAE This family contains a single species, the pirate perch, Aphredoderus sayanus. An interesting feature of this species is the jugular location of the anus in adults (Fig. 15B). The location of the anus gradually migrates forward as the fish increases in size until the anus attains a position under the throat in adults. Aphredoderus sayanus (Gilliams) - pirate perch Key Characters: Jugular position of anus; large mouth. Well-developed lateral line. Dark vertical band on caudal peduncle.. Body color dark olive to gray; body may be.speckled. Dorsal spines 3 with 2 anal. spines. SRP Distribution: Abundant. One of the more ubiquitous fish on the SRP. Collected from all

streams, Par
Pond, and Skinface l?ond but rare in the Savannah River.

Habitat and Habits: Collected around undercut banks and instream cover in streams and lakes. Occurs in shallow *water << 30 cm). This species exhibits

, I I 92 a predatory feeding behavior. Pirate perch spawn in a nest which is subse-quently guarded. Size: SRP maximum 14.5 em, 28 g. Length-weight relationship (N =62, r = 0.98) is In W= 3.05 (In TL) - 11.53. ORDER - ATHERINIFORMES NEEDLEFISH FAMILY - BELONIDAE Belonids are generally considered marine fishes but a few specimens have been captured in the Savannah River. Members of the family are easily recognized by their long slender bodies with both jaws greatly elongated to form a beak. Needlefish superficially resemble gar (Lepisosteus) but can be easily distinguished by their silvery coloration and the absence of ganoid scales. Strongylura marina (Walbaum) - Atlantic needlefish Key Characters: Body rounded. Jaws elongated. Gill rakers absent. Anal fin rays 16 to 20. Dorsal fin rays 14 to 17. Lateral line low on body. Fins without spines. Body soft, scales small and flexible. SRP Distribution: Rare. A few collected in cooling intake canal off Savan-nah River. Probably enter mouths of larger tributaries. Habitat and Habits: Found around docks and trees or some other type of cover. Size: SRP maximum 32.5 cm, 48.5 g.

93 KILLIFISH FAMILY - CYPRINODONTIDAE Killifish possess small upturned mouths for surface feeding. Most are small fishes rarely exceeding 10 cm in total length. The caudal fin is rounded and the lateral line is partially developed. Pelvic fins are abdomi-nal in position. Fertilization is external. Fundulus lineolatus, the lined topminnow, has been the only species of killifish collected on the SRP. Fundulus lineolatus (Agassiz) - lined topminnow Synonyms: Zygonectes notti (Fowler 1945); Fundulus notti (ANSP 1961); Fundu-lus dispar lineolatus (ANSP 1957). Key Characters: Small body size with protruding lower jaw with the mouth opening dorsally. Concentration of melanophores below eye. Top of head flattened. Dorsal fin located posteriorly. The sex of adult Fundulus lineo-latus can be determined by the direction of the stripes (bands) on the body; males have vertical bands and orange on top of their head; females have longitudinal stripes and lack the orange cap. Both vertical bands and longi-tudinal stripes are apparent in juvenile fish. SRP Distribution: Common. Occurs in all major creeks on the SRP and has been occasionally collected from the Savannah River and Skinface Pond. Habitat and Habits: A species collected in sluggish streams, backwaters, and swamps. Topminnows feed on small crustaceans and insects. They are late spring and early summer spawners. Size: SRP maximum 7.5 cm, 3.8 g. Length-weight relationship (N = 46, r = 0.98) is In W= 3.34 (In TL) - 13.01.

Reference:

Brown 1957, 1958; Rivas 1966; Goodyear 1970.

94 92 TOPMINNOW FAMILY - POECILIIDAE The mosquitofish, Gambusia affinis, is the only poeciliid on the SRP.. Gambusia look similar to members of the family Cyprinodontidae and are often confused with the killifishes. Both are small fishes, but Gambusia lack stripes; sexually mature male G. affinis have a modified anal fin used as an intromittent organ. Because of their ubiquity, abunqance, and ease of collection, ~. affinis have been used widely as research animals on the SRP. Their mode of reproduc-tion, being livebearers, and sexual dimorphism have also contributed to their widespread use in many studies. Their abundance in thermally altered en-vironments has been well documented (Smoak 1959, Ferens and Murphy 1974, Bennett and Goodyear 1979). Gambusia affinis (Baird and Girard) - mosquitofish Synonyms: Gambusia holbrooki (Fowler 1945); G. a. holbrooki is the recog-nized subspecies on the SRP. Key Characters: Body small, head flattened. Caudal, dorsal, and anal fins

round, no distinct stripes or bands.

Dorsal fin rays 8. Anal rays 10. Modified anal fin in males. Gravid females with dark lateral spot. Maximum body size 6 em. SRP Distribution: Abundant. Found in nearly all aquatic environments on the SRP including Carolina bays and farm ponds. Particularly abundant in ther-mally influenced streams, swamps, and impoundments. Habitat and Habits: Slow moving streams, backwaters of streams with higher

gradient, ponds, Carolina bays, and lakes with various bottom types (mud, silt, sand, gravel).

Bear live young. SRP mosquitofish feed on cladocerans, rotifers, copepods, larval and adult dipterans, and ostracods.

) 95 Size: SRP maximum 5.2 cm, 1.25 g. Length-weight relationship (N = 70, r = 0.98) is In W=3.04 (In TL) - 4.88.

References:

Aho et al.

1976, Cherry et al.

1976, Falke and Smith 1974, Bennett and Goodyear 1979, Goodyear et al. 1972, Goodyear and Ferguson 1969, Goodyear 1973. SILVERSIDE FAMILY - ATHERINIDAE Members of the silverside family are slender fishes rarely attaining lengths over 10 cm. Atherinids can be readily identified by their divided dorsal fin; the spinous section has four spines followed by a larger soft-rayed section. Lower jaw extending beyond upper jaw. Snout dorso-ventrally flattened. The single representative of this family on the Savannah River Plant is the brook silverside, Labidesthes si~culus. They are commonly seen in ,1 iI schools jumping out of the water to avoid predators. Brook silversides are used as food items by larger fishes and have been stocked as prey for preda-tory fishes by many state fishery management agencies. Labidesthes sicculus (Cope) - brook silverside Key Characters: Body long and thin with a pointed snout (viewed dorsally). Premaxillary triangular-shaped, forming.a beak when viewed from above. Pre-dorsal scales crowded, more than 23. Pale green color with a wide, silvery band. SRP Distribution: Common. Silversides have been collected from all creeks except Pen Branch and the Salkehatchie River. They are common in the Savan-nah River and abundant in Par Pond system.

96 Habitat and Habits: A schooling, pelagic fish. Found actively swimming in schools and feeding on plankton organisms. In lotic habitats, brook silver-sides are more common in still, back waters. Size: Maximum length about 10 cm. SRP maximum 8.4 cm, 3.8 g. Length-weight relationship (N = 64, r = 0.98) is InW = 3.04 (In TL) - 12.22.

Reference:

Frietsche et al. 1979. ORDER - PERCIFORMES TEMPERATE BASS FAMILY - PERCICHTHYIDAE The temperate bass family is represented on the SRP by two species, the white bass, Morone

chrysops, and the striped bass, Morone saxatilis.

The similarities between these species can cause some confusion in identifica-tion. Hybrids between the two species have been stocked in Savannah River reservoirs upstream of the SRP. Because of the sport-fish interest in striped bass, much research has been undertaken to evaluate the spawning habits of this species throughout its range. The Savannah River may be the only watershed where striped bass migrate downstream, rather than

upstream, to spawn (Dudley et al.

1977). Observations of striped bass in SRP streams are limited to late summer or winter. There is no evidence that they spawn upstream or on the SRP. Striped bass are an important sportfish at the New Savannah Bluff Lock and Dam, up-stream from the SRP. Fish in this family can be distinguished by their 7 dark longitudinal stripes along the sides of the body, moderately large mouths, separation of i spiny and soft dorsal fins, and the presence of three anal fin spines.

97 Key to Species of Percichthyidae 1. Scales small, lateral line scales 57 to 67; lateral stripes not inter-rupted and not interspaced by secondary rows of fainter stripes; 'depth of body less than 1/3 standard length; teeth on back of tongue in 2 parallel patches Morone saxatilis - striped bass page 97 j Scales large, lateral line scales 52 to 58; lateral stripes on sides usually interrupted, and consisting of rows of primary stripes inter-spaced by fainter secondary stripes; depth of body more than 1/3 standard length; teeth on back of tongue in a single patch ................................. Morone chrysops - white bass page 97 Morone chrysops (Rafinesque) - white bass Synonyms: Perea chrysops, Lepibema chrysops (Fowler 1945), Roccus chrysops (ANSP 1963). Key Characters: Separation of spiny and soft dorsal fins. Mouth moderately large. Longitudinal stripes (7) on sides broken. Depth of body more than 1/3 standard length. Lateral line scales 52 to 58. Teeth on back of tongue in a single patch. SRP Distribution: A rare, introduced species reported only from the Savannah River (McFarlane et al. 1978). Habitat and Habits: Large sluggish rivers and impoundments. A schooling fish that is commonly found around cover. Concentrates in shallow water dur-ing spring while spawning. Feeds on aquatic invertebrates and fish. Size: Maximum size about 3 kg. Morone saxatilis (Walbaum) - striped bass Synonyms: Roccus saxatilis Key Characters: Separation of spiny and soft dorsal fins. Mouth moderately large. Longitudinal stripes (7) on sides not broken. Depth of body less than 1/3 standard length. Scales small, lateral line scales 57 to 67. Teeth on back of tongue in 2 parallel patches.

98 SRP Distribution: The Savannah River and Upper Three Runs Creek. Habitat and Habits: Large rivers and reservoirs. Pelagic species that com-monly feeds in schools. Most landlocked populations originated from embryos taken from the Santee Cooper stock in eastern South Carolina. Feeds primari-lyon fish. An important sport fish. Size: Maximum size about 45 kg. SRP maximum about 10 kg.

References:

Dudley et al. 1977, Smith 1968. SUNFISH FAMILY - CENTRARCHIDAE The sunfish family is the largest family of fishes on the SRP. Seven-teen species of centrarchids have been collected in lotic and lacustrine habitats on the site. Family representatives are relatively easy to identi-fy, although the identification of juveniles is difficult. Length of the pectoral fins and gill rakers and the number of spines are key characters used to identify some of these species. The spinous and soft rayed portions of the dorsal fin are characteristically united in members of this family. Mouth size varies from small to very large. Centrarchids are known to many people because of their popularity as sport fishes. The largemouth bass, Micropterus salmoides, reaches a larger size than any other member of this family on the SRP. Most centrarchids, because of their secretive habits and preferred habitats, are rarely seen by most observers. Pygmy sunfishes, for

example, inhabit sluggish streams having marshy, backwater areas; the banded sunfishes are generally found in clear, moving waters with dense growth of aquatic vegetation.

99 Key to the Species of Centrarchidae 1. Lateral line absent; dorsal fin spines 4 or 5; usually 1 to 3 dark spots on side below origin of dorsal fin; rounded pectoral; pelvic fins pointed and long; vertical bands on body; maximum size less than 5 cm Elassoma zonatum - banded pygmy sunfish page 105 Lateral line complete or nearly complete; dorsal fin spines 5 to 13; maximum size greater than 5 em.. 2 2. Base of dorsal fin equal to or slightly longer than base of anal fin... 3 Base of dorsal fin much longer (about 5X) than base of anal fin........ 5 3. Dorsal fin spines more than 10; anal fin spines usually 7 or 8; young with an ocellus located in posterior end of soft dorsal fin; each scale with a dark spot Centrarchus macropterus - flier page 104 Dorsal fin spines fewer than 10; anal fin spines fewer than 7, usually 6; dorsal fin spot, if present, not ocellated; some scales may have spots but not all...................................................... 4 4. Dorsal fin spines 7 or 8; distance from eye to front of dorsal fin base about equal to length of base of dorsal fin ........................ Pomoxis nigromaculatus - black crappie page 112 Dorsal fin spines 5 or 6; distance from eye to front of dorsal fin base greater than length of base of dorsal fin ............................ Pomoxis annularis - white crappie page 112 5. Caudal fin rounded. 6 Caudal fin shallow to deeply forked.................................... 9 6. Mouth large, maxillary extending behind middle of eye; anal fin spines 5 or 6; sides with dark scales giving appearance of 5 indistinct dark longitudinal stripes; scales cycloid ........................... Acantharchus pomotis - mud sunfish page 104 Mouth small, maxillary barely extending to front of eye; anal spines 3 or 4; stripes, if present, are vertical; scales ctenoid.............. 7 7. Front of dorsal fin dark; dorsal spines 10; palatine teeth absent; sides with dark vertical bands..............*.......................... ................. Enneacanthus chaetodon blackbanded sunfish page 105 Front of dorsal fin not dark; dorsal fin spines usually 9; palatine teeth present; sides may have distinct to indistinct vertical bands (bands more noticeable in young) .................Enneacanthus gloriosus - bluespotted sunfish page 106 8. Body elongate and slender, greatest depth usually 1/3 standard length (except in very large adults); spinous dorsal fin and soft dorsal

100 fin nearly separate; dark lateral stripe; scales small, lateral line with 55 or more scales ....................... Micropterus salmoides-Iargemouth bass page 111 Body deep and compressed, greatest depth usually more than 1/3 standard length; spinous dorsal fin and soft dorsal fin completely united; no dark, lateral stripe; scales large, lateral line with fewer than 55 scales........................................*. genus Lepomis 9 9. Tongue with teeth; mouth large, maxillary extending to middle of eye; several distinct dark lines radiating back from eye ...........*..................... Lepomis gulosus - warmouth page 108 Tongue without teeth; mouth small (maxillary extending only to front of eye) or large; no distinct dark lines radiating back from eye....... 10 10. Opercle stiff to the posterior bony margin; posterior end of opercular flap usually fractures if bent sharply forward......................... 11 Opercle flexible to the posterior margin; posterior end of opercular flap may be bent sharply forward without fracturing opercular bond..... 14 11. Pectoral fins short and rounded, tips not reaching nostril when laid forward over the cheek................................................. 12 Pectoral fins long and pointed, tips, reaching nostril when laid for-ward over the cheek.................................................... 13 12. Mouth large, maxillary extending to middle of eye; gill rakers long when depressed extending to base of 2nd or 3rd raker below; all scales not pigmented Lepomis cyanellus green sunfish page 107 Mouth small to moderate, maxillary extending to front of eye; gill rakers short, not extending to base of 2nd or 3rd raker below; each scale pigmented at base; sides usually with numerous dark spots scat-tered over body (less noticeable in young) ...............*......... Lepomis punctatus-spotted sunfish page 110 13. Opercle with a small, red, semicircular spot near its margin; anal fin and posterior of dorsal fin with distinct spots (prolonged preservation may bleach spots); first anal fin spine equal in length to diameter of eye; rear margin of opercle stiff (excluding flap) ............................ Lepomis gibbosus - pumpkinseed page 107 Opercle margined in scarlet; no spots on anal or dorsal fins; first anal fin spine shorter than diameter of eye; rear margin of opercle thin and flexible Lepomis microlophus-redear sunfish page 110 14. Pectoral fins rounded; gill rakers short and "nob-like" (Fig. 20A); opercular membrane not dark to its margin, bordered by greenish, red or white Lepomis marginatus-dollar sunfish page 109

A. B. 101 Dollar Sunfish Bluegill Figure 20. Appearance of nob-like (A) and long (B) gill rakers in Lepomis (after Eddy 1957; see Appendix I). Figure 21. Ventral scale development between pelvic fins and anus in Percina (A) and selected Etheostoma (B after Eddy 1957; see Appendix I).

Table 4. Characters useful in the identification of the species of Centrarchidae. I-' 0 l\\.) 1 Gill 2 Dorsal Fin Dorsal Pectoral Anal Fin Caudal Species Mouth Rakers Spines Fin Fin Spines Fin Other Coloration mud large 12 rounded 5 convex horizontal sunfish bands on head flier moderate 11-12 spotted moderately 7-8 emarginate ocellus present pointed in young banded moderate 4-5 pointed 3 convex lateral pygmy line absent sunfish black-small 10 front of rounded 6 convex vertical bars banded fin black on sides sunfish blue-moderate 9 spotted rounded 6 convex spotted sunfish redbreast moderate short 10 pointed 3 emarginate blue lines on sunfish cheek green large long 10 dark

short, 3

emarginate sunfish blotch rounded pumpkinseed small short 10 spotted

long, 3

emarginate blue lines on pointed cheek warmouth large short 10 may have rounded 3 emarginate dark lines on blotch head; teeth on tongue

Table 4. Continued. Species bluegill dollar sunfish redear sunfish spotted sunfish largemouth bass 1 .Mouth small small small moderate very large Gill 2 Rakers long short short long Dorsal Fin Spines 10 10 10 10 10 Dorsal Fin Coloration dark blotch Pectoral Fin

long, pointed moderately pointed
long, pointed
short, rounded moderately rounded Anal Fin Spines 3

3 3 3 3 Caudal Fin emarginate emarginate emarginate emarginate emarginate Other vertical bars on sides each scale on side spotted lateral stripe; deeply notch-ed dorsal fin white large 6 mottled moderately 6 emarginate crappie rounded black large 7-8 reticulated moderately 6 emarginate distinct ver-crappie rounded tical bars on sides lIn relationship to a vertical line extending upward from the posterior margin of the upper jaw, small - line does not reach eye moderate - line reaches anterior margin of eye large - line reaches pupil of eye very large - line extends posterior to eye 2Short - gill rakers twice (or less) as long as wide Long - gill rakers several times longer than wide I-'ow

104 Pectoral fins pointed, or, if fin appears round, gill rakers long and not "nob-like"; opercular membrane dark to its margin ................................. Lepomis macrochirus-bluegill page 109 Gill rakers short, length about 2X width and, when depressed, not ex-tending to base of 2nd raker below; pectoral fin short, extending to eye when bent forward; opercular lobe stiff and dark to margin ............................. Lepomis auritus-redbreast sunfish page 106 A summary of characters most useful in identifying sunfishes is presented in Table 4. Acantharchus pomotis (Baird) - mud sunfish Key Characters: Mouth large, maxillary extending to middle of eye. Anal fin spines 5 or 6. Scales cycloid. Presence of 5 or 6 longitudinal stripes to caudal fin. SRP Distribution: Uncommon, but occurring in small tributary streams of all creeks on the SRP. Rare in Savannah River. Found in Sarracenia Bay and in tributaries of Par Pond. Habitat and Habits: Slow moving, small sluggish tributaries and Carolina bays having a bottom type of high organic matter and vegetation. Adults "rest" head down in weeds and are active at night. Spawn in mid-spring. Size: Maximum size about 21 cm and 190 g. SRP maximum 15.6 cm, 87 g. Length-weight relationship (N = 12, r = 0.99) is In W= 3.34 (In TL) - 12.44. Centrarchus macropterus (Lacepede) - flier Key Characters: Body flattened laterally. Dorsal spines more than 10. Anal spines usually 7 or 8. Young with blue bands and dark spot outlined in orange (ocellus) on posterior dorsal fin. Base of dorsal fin equal to length of anal fin.

Spawns in nests. 105 SRP Distribution: Uncommon. Based on recent and previous surveys, fliers occur in small numbers in all major creeks. Also found in some Carolina

bays, Skinface
Pond, Twin
Lakes, and occasionally in the Savannah River.

Habitat and Habits: Backwater area of streams and Carolina bays having ex-tensive growths of submergent and emergent vegetation. Feeds on cladocerans and aquatic insects. Size: Maximum size about 20 cm and 450 g. SRP maximum 19 cm, 122 g. Length-weight relationship (N = 71, r =.99) is In W= 3.13 (In TL) - 11.54. j Elassoma zonatum Jordan - banded pygmy sunfish Key Characters: Small body size. Lateral line absent. Dorsal fin spines 4 or 5. One to three dark spots on side below origin of dorsal fin. SRP Distribution: Uncommon. Collected at various times from all major creeks. Not collected recently from Four Mile Creek and Pen Branch. Col-lected from shoreline areas and tributaries of Par Pond system, Moon Lake, Sarracenia Bay, and SkinfacePond. Habitat and Habits: Swamps, Carolina bays, and backwaters of streams having abundant growths of vegetation or high organic matter. Spawn over vegeta-tion. Food is crustaceans and insects. Size: Maximum length about 4 cm. Enneacanthus chaetodon (Baird) - blackbanded sunfish Synonyms: Mesogonistus c. chaetodon (Freeman 1954). Key Characters: Caudal fin rounded. Mouth small. Front of dorsal fin dark. Dorsal spines usually 9. Sides usually with distinct, broad vertical bands. SRP Distribution: Uncommon. Collected only from Upper Three Runs Creek. This is the only known locality for this species in the Savannah River drain-age.

106 Habitat and Habits: Backwater areas having low current and areas with dense aquatic vegetation (e.g. Valisineria sp. beds). Size: Maximum length about 10 cm.

Reference:

Jenkins et al. 1975. Enneacanthus gloriosus (Holbrook) - bluespotted sunfish Key Characters: Caudal f~n rounded. Mouth small. No darkening of dorsal fin. Dorsal fin spines 9. Opercular spot smaller than pupil. Sides without distinct vertical bands. Few to no spots on spiny dorsal fin. SRP Distribution: Common. Collected at various times in most major creeks, except Four Mile and Upper Three Runs. Also collected in Skinface Pond. Rare in the Savannah River. Habitat and Habits: Found in streams with abundant vegetation. Spawn over mats of algae or in nests. Feed primarily on small crustaceans, aquatic in-sects, and molluscs. Size: Maximum length about 10 cm. SRP maximum 7.7 cm, 10 g. Length-weight relationship (N = 56, r = 0.99) is ln W= 3.20 (In TL) - 11.76. Lepomis auritus (Linnaeus) - redbreast sunfish Key Characters: Anal fin spines 3. Mouth small. Opercle long (adults) flexible and black. Pointed pectoral fins extending to eye. Gill raker length about 2X width. Prominent wavy blue lines on cheek. Body more elon-gate than other Lepomis species. SRP Distribution: Abundant. Found in all creeks (except the Salkehatchie River), the Savannah River and swamp, the Par Pond system, and most ponds. Habitat and Habits: Pool areas of higher gradient streams to open water in lower gradient streams. Littoral areas of lakes and ponds. Usually associ-

107 ated with cover during the day. Insects constitute the bulk of the diet. Spawns during spring. Size: Maximum size about 24 cm and 312 g. SRP maximum 23.2 cm, 310 g. Length-weight relationship (N = 100, r =.97) is In W= 3.01 (In TL) -.10.99.

References:

Lattimore and Gibbons 1974, Hogan 1977. Lepomis cyanellus Rafinesque - green sunfish Key Characters: Forked caudal fin. Maxillary extending behind middle of eye. Opercle stiff to posterior margin. Pectoral fins short and rounded. )- Dorsal spot at posterior of dorsal fin. Gill rakers long. SRP Distribution: Rare. Collected during earlier surveys in Upper Three Runs (Whitworth 1969) and Lower Three Runs (Freeman 1958) Creeks. Not col-lected during recent surveys. An introduced species in the Savannah River (Dahlberg and Scott 1971b); its present occurrence on SRP requires verifica-tion. Green sunfish may be confused with warmouths, which frequently have a large spot in the dorsal fin on SRP. Habitat and Habits:

Warm, muddy-bottomed, turbid pools in streams.

Associ-ated with vegetation in reservoirs and ponds. Juveniles consume zooplankton then shift with increased body size to aquatic insects and fish. Size: Maximum size of 27 cm and 408g. Lepomis gibbosus (Linnaeus) - pumpkinseed Synonyms: Pomotis gibbosus (Fowler 1945) Key Characters: Gibbo~s-shaped. Caudal fin forked. Opercle stiff to mar-gin. Pectoral fins long and pointed. Gill rakers short and curved. Opercle with a small red semicircular spot near margin. Anal and posterior of dorsal fin with spots. Often confused with L. microlophus. SRP specimens are dif-

107 ated with cover during the day. Insects constitute the bulk of the diet. Spawns during spring. Size: Maximum size about 24 cm and 312 g. SRP maximum 23.2 cm, 310 g. Length-weight relationship (N = 100, r =.97) is In W= 3.01 (In TL) - 10.99.

References:

Lattimore and Gibbons 1974, Hogan 1977. Lepomis cyanellus Rafinesque - green sunfish Key Characters: Forked caudal fin. Maxillary extending behind middle of eye. Opercle stiff to posterior margin. Pectoral fins short and rounded. Dorsal spot at posterior of dorsal fin. Gill rakers long. SRP Distribution: Rare. Collected during earlier surveys in Upper Three Runs (Whitworth 1969) and Lower Three Runs (Freeman 1958) Creeks. Not col-lected during recent surveys. An introduced species in the Savannah River (Dahlberg and Scott 1971b); its present occurrence on SRP requires verifica-tion. Green sunfish may be confused with warmouths, which frequently have a large spot in the dorsal fin on SRP. Habitat and Habits: Warm, muddy-bottomed, turbid pools in streams. Associ-ated with vegetation in reservoirs and ponds. Juveniles consume zooplankton then shift with increased body size to aquatic insects and fish. Size: Maximum size of 27 cm and 408 g. Lepomis gibbosus (Linnaeus) - pumpkinseed Synonyms: Pomotis gibbosus (Fowler 1945) Key Characters: Gibbous-shaped. Caudal fin forked. Opercle stiff to mar-gin. Pectoral fins long and pointed. Gill rakers short and curved. Opercle with a small red semicircular spot near margin. Anal and posterior of dorsal fin with spots. Often confused with L. microlophus. SRP specimens are dif-

108 ficult to separate from ~. microlophus on the basis of pectoral fin length. SRP Distribution: Rare in the Savannah River, which is the southernmost limit of distribution of the species. Reported from Four Mile Creek in an earlier survey (Freeman 1954). Habitat and Habits: Lives in cooler waters than other Lepomis. Quiet clean water with slight amount of organic debris and aquatic vegetation. Nest near shore and manifest parental care of nest and young. Feed on crustaceans, snails, insects, and fish during day. Size: Maximum size about 40 cm and 450 g. SRP maximum 24 cm, 315g. Length-weight relationship (N = 67, r = 0.99) is In W= 3.13 (In TL) - 11.54. Lepomis gulosus (Cuvier) - warmouth Synonyms: Chaenobryttus coronarius (Fowler 1945, Freeman 1954). Key Characters: Mouth

large, maxillary extending behind middle of eye.

Forked caudal fin. Three anal fin spines. Dark stripes radiating from eye to opercle. Teeth patch on tongue. SRP Distribution: Abundant. Collected from all major creeks on SRP. Common in the Savannah River, abundant in the Par Pond system and farm ponds, and occasionally collected in Carolina bays. Habitat and Habits: Juveniles inhabit areas of dense vegetation while adults are found in more open water. Occurs in slower waters of tributary streams, larger creeks, farm ponds, Carolina bays, and reservoirs. Aggressive feed-ers;

insects, crayfish and fish are main food items.

Spawn in nest near a stump or clump of vegetation during spring and summer. Size: Maximum length 28 cm. SRP maximum 24 cm, 298 g. Length-weight re-lationship (N = 100, r = 0.99) is In W= 3.10 (In TL) - 11.34.

109 Lepomis.macrochirus Rafinesque - bluegill Synonyms: Icthelis macrochira (Fowler 1945) Key Characters: Opercle flexible (stiff in young). Pectoral fins long and pointed. Gill rakers long, 6X width. Dark spot at base of soft dorsal fin. Juveniles with dark, straight distinct vertical bands with distinct margins. SRP Distribution: Common. Found in all major tributaries, the Par Pond system, and farm ponds. Bluegill are abundant in the Savannah River. Habitat and Habits: Ponds, lakes and sluggish streams. Larval bluegill ex-perience a limnetic stage for about two months and then migrate to occupy

shallow, on-shore areas.

Larger fish are found in more open waters. Adults feed on crayfish, fish and terrestrial and aquatic insects. Aquatic vegeta-tion may be present but is probably incidental. An important forage fish for largemouth bass. Colonial spawner with two peaks spawning activity in the late spring and summer. Commonly feed on surface. Size: Maximum length about 30 cm. SRP maximum 27 cm, 302 g. Length-weight relationship (N = 100, r =.99) is ln W= 3.10 (In TL) - 11.39.

References:

Avise and Smith 1974a, 1974b; Bennett 1972b; Beisser 1978; Benke and Benke 1975; Murphy et al. 1976; Goodyear and Bennett 1979; Johnson 1976; Yardley et al. 1974. Lepomis marginatus (Holbrook) - dollar sunfish Key Characters: Opercle flexible to its posterior margin. Pectoral fins round. Opercular membrane not dark to its margin, bordered by green, red, or white. Gill rakers short, rounded and "nob-like" (Fig.*20A). SRP Distribution: Abundant. A widely distributed species occurring in all maj or tributaries, streams and most farm ponds. Rarely collected in the Savannah River.

110 Habitat and Habits: Undercut

banks, surrounding cover (logs,
branches, rocks, etc.) in small streams.

More abundant in smaller streams. Active in littoral areas of ponds and lakes. Food items are aquatic invertebrates and small fish. Size: Maximum length about 18 cm. SRP maximum 14 cm, 138 g. Length-weight relationship (N = 66, r = 0.99) is In W= 3.17 (In TL) - 11.78. Lepomis microlophus (Gunther) redear sunfish Key Characters: Opercle long,

wide, and stiff to its posterior margin and margined in scarlet.

Pectoral fins long and pointed. Gill rakers short. No spots on anal and dorsal fins. May be confused with~. gibbosus. SRP Distribution: Common. Collected from all major creeks on the SRP except the Salkehatchie River; common in the Savannah River. Commonly collected in Twin Lakes and occasionally in Par Pond system. Introduced into Skinface Pond. Habitat and Habits: Large, warm rivers, bayous, lakes and ponds. Spawn in spring and summer in nests grouped in colonies around submerged vegetation. Insect larvae, snails, and cladocerans are important food items. Seldom feed on surface. Size: Maximum size 35.5 cm and 1270 g. SRP maximum 28 cm, 470 g. Length-weight relationship (N = 100, r = 0.99) is In W = 3.28 (In TL) 12.33. Lepomis punctatus (Valenciennes) - spotted sunfish Key Characters: Opercle stiff. Opercular lobe short and black. Pectoral fins short and rounded. Mouth moderate, maxillary extending to front of eye. Gill rakers short and curved. Sides may have dark spots scattered over body.

111 SRP Distribution: Abundant~ Collected from all major creeks on the SRP except the Salkehat~hie River. Uncommon in the Savannah River. Found in the Par Pond system and in farm ponds. Habitat and Habits~' Found in a greater diversity of habitats than other Lepomis. Collected from small, sandy bottomed, moderate gradient tributaries to

large, low gradient creeks.

Usually found around vegetation or other forms of cover. Summer spawners; males savagely protect the nest. Size: Maximum size about 17 em. SRP maximum 17 cm, 119 g. Length-weight relationship (N = 58, r = 0.98) is In W= 3.16 (In TL) - 11.45. Micropterus salmoides (Lacepede) - largemouth bass Synonyms: Huro floridana (Fowler 1945). Key Characters: Caudal fin forked. Mouth large, maxillary extending behind eye. Spinous dorsal separated from soft dorsal fin by a deep notch extending nearly to base of fin. Body elongated. Dark, wide, lateral band present. SRP Distribution: Common. Found in the Savannah River, the swamp, and all major creeks on the SRP. Abundant in Par Pond system and collected iri Dicks Pond, Skinfaee Pond, and B-Swamp. Habitat and Habits: Prefer nonflowing clear waters with aquatic vegetation. Cover is an important factor affecting abundance in creeks, lakes, and'-reser-voirs. Spawn from March May; males afford parental care'to nest and young. Bass feed on entomostraeans, insect larvae, and fish. Fish, however, are the primary dietary component of adults. Size: Maximum size about 10 kg. SRP maximum from the river 34 cm,440 g. Maximum from Par Pond 60 em, 5 kg. Length-weight relationship (N =53, r = 0.99) is In W= 3.09 (In TL) - 11.73.

"-~ 112

References:

Bennett

1972a, 1979; Bennett and Gibbons
1972c, 1974,1975; Dupont 1976; Esch et al.

1976; Eure 1974,

1976a, 1976b, Eure and Esch 1974; Gibbons et al.

1972; Gibbons and Bennett 1973; Gibbons et al. 1978; Goodyear and Boyd 1972; Harvey 1964; Holland et a1. *1974; Quinn et a1. 1978; Siler 1975; Smith and S~ott 1975. Pomoxis annularis Rafinesque - white crappie Key Characters: Gibbous shape. Length of anal fin base equal to length of dorsal fin base. Dorsal and anal spines usually 5 or 6. Distance from eye to front of dorsal fin base greater than length of base of dorsal fin. SRP Distribution: Rare. An introduced species, formerly more common than P. nigromaculatus in the Savannah River but.now rare. This change in abundance may be associated with reduced turbidity and lower water temperatures in the river since construction of Clarks Hill Dam. Also collected in Lower Three Runs Creek. Habitat and Habits: Inhabit

lakes, bayous and slow moving streams and Pomoxis nigroma~ulatus (Lesueur) - black crappie Key Charact.ers:
.Gibbous shape..
  • Dorsal spines 7.. or 8.

Length of anal fin base equal to .length of do:r;s.al fin base. Distance from eye to front of dorsal fin base equal to base of dors~l fin.

SRP Distribution: Common. 113 Collected from maj or tributaries on the SRP except Pen Branch, Steel Creek and the Salkehatchie River. Common in the Savannah River and the Par Pond system. Habitat and Habits: Prefer clear,

deep, cool waters of both lotic and lentic habitats.

Spawn in early spring over gravel or sand nests at the base of vegetation or other cover. Food of juveniles is entomostracans; food of adults is insects and forage fish. Black crappie have become more abun-dant in the Savannah River since the completion of Clarks Hill Dam. Size: Maximum size about 37 cm. SRP maximum 33 cm, 414 g. Length-weight relationship (N = 66, r = 0.98) is In W= 3.33 (In TL) - 13.01.

Reference:

Bennett 1972b. PERCH FAMILY - PERCIDAE Percids are an important family of freshwater fishes represented by seven species on the Savannah River Plant. Only one of these, the yellow

perch, Perca flavescens, is commonly seen.

Yellow perch are frequently captured by angling. The remaining six species are darters, fishes that are found over sand and gravel bottoms and rapidly "dart" from one area to the next. Members of the Percidae are characterized by having the spiny and soft portions of the dorsal fin completely separated and the anal fin with one or two spines. Even some ichthyologists have difficulty identifying darters because of their intraspecific variability and interspecific similarities. Few simple taxonomic characters have been recognized for separating the species. A useful introduction to darter biology is provided by Winn (1958).

1;1.4 Key to the Species of Percidae 1. Mouth large, maxilla extending to middle of eye; posterior upper border of maxilla not concealed under preorbital; preopercle strongly ser-rate; branchiostegal rays 7 or 8; pseudobranchiae well developed; body size in adults large (>250 rom); Perca flavescens - yellow perch page 119 Mouth small, maxilla not extending to middle of eye; maxilla con-cealed posteriorly by preorbital; preopercle entire or weakly serrate; branchiostegal rays usually 6; pseudobranchiae poorly developed or absent; adults small <<125 rom)......................................... 2 2. Lateral line complete or nearly complete (occasionally incomplete in ~. olmstedi) Lateral line incomplete, usually extending to median of soft dorsal fin 4 3 3. Preopercle not serrate; snout blunt; dorsal fin formula VIII to XII, 9 to 12; anal' fin formula II, 6-9; scales along lateral line 40-63; sides marked with about nine (9) blotches or dark bands; caudal base with a vertical row or 3 or 4 dark spots Etheostoma fusiforme - swamp darter page 116 Preopercle serrate; snout blunt; dorsal fin formula X to XI - 12 to 15; anal II, 6 to 8; lateral line highly elevated, with 28-38 pores; scales along lateral line usually 50-58; dorsal saddles and blotches absent; lateral blo~ches large and irregular; base of caudal with ver-tical row of 4 spots .................. Etheostoma serriferum - sawcheek darter page 119 4. Area of anal fin usually as large a.s area of soft dorsal fin; mouth terminal; "diamond-shaped" blotches aloQ.g each side (diamonds may appear as dark, wide band in juveniles); belly without scales .................. Percina nigrofasciata - blac~banded darter page 119 Area of anal fin usually smaller than area of soft dorsal fin; mouth . terminal or slightly inferior; sides without diamond blotches.......... 5 5.* Premaxillary protractile,separated from snout by a complete groove (frenum absent; Fig. 22A).............................................. 6 Premaxillary not protractile, not entirely separated from snout by a groove (frenum present), but connected anteriorly by a fleshy bridge (Fig. 22B)............................................................. 7 6. Snout very blunt; belly completely naked; sides with 9-11 "w" or "X" markings; anal spines thin and flexible, about equal in length; .....................Etheostoma olmstedi - tessellated darter page 118

115 A. ~ ~ /'.. Figure 22. Comparison of protractile (A) and non-protractile (B) premaxil-laries in perciQ fishes. Note absence (A) and presence (B) of

frenum, as indicated by arrow (after Blair et al.

1968). (See Appendix I).

116 Snout a gentle curve from eye level to snout tip; belly naked anteri-orly only; sides without "WlI or "Xli markings; anal spines typically two, the first heavy and thick and being appreciably thicker than 2nd spine Etheostoma inscriptum - turquoise darter page 118 7. Cheeks naked or with a few deeply imbedded scales; predorsal partially scaled; scales along lateral line fewer than 45; dorsal fin formula X or XII-II to 13; anal II, 8 or 9; dorsal blotches absent but 5 blotches on upper sides near dorsal base; infraorbital bar forming an arc curving downward and backward; preorbital bar present ....................~.... Etheostoma fricksium - Savannah darter page 116 Cheeks well scaled; predorsal heavily scaled; scales small, more than 45 on lateral. line; dorsal X or XI, 11 to 13; anal 11,7-9; dorsal blotches 'usually 7 or 8; males with 10 red or red-orange bars alter-nating with green on sides; predorsal area with 2 poorly to well-de-veloped dark blotches; prepectoral dark spot usually present; infra-orbital canal complete with usually 8 pores ........................ Etheostoma hopkinsi - Christmas darter page 117 Etheostoma fricksium Hildebrand - Savannah darter Synonyms: Poecilichthys fricksia (Freeman 1954) Key Characters: Body elongate and slender. Dorsal fin with completely sepa-rated spiny and soft portions. Lateral line nearly complete. Cheeks usually without scales. Belly scaled. Scales along lateral line fewer than 45. Indistinct vertical bands on caudal peduncle. Preorbital bar present. SRP.Distribution: Rare. Reported from Upper Three Runs, Lower Three Runs and'St~el Creek. Unknown in the Savannah River at SRP. Habitat and Habits: Found only in clear streams with a sand or gravel bot-tom. Food is primarily aquatic insects. Size: Maximum length about 7 em.

Reference:

Hilderbrand 1923. Etheostoma fusiforme (Girard) - swamp darter Synonyms: Etheostoma barratti (Freeman 1954); Boleichthys fusiformis (Fowler 1945);.Hololepis barratti (ANSP 1953)

Key. Characters: Body elongate and slender. 117 Spiny and soft portions of dorsal fin separated. Lateral line inc?mplete. with a row of 3 or 4 dark spots. Snout blunt. .Caudal base SRP.Distribution: Rare. Collected from all creeks except Four Mile arid**Pen Branch. This is the only darter known from Par Pond.system; it is rare in the Savannah River. Habitat and Habits: Swamps and backwaters of

streams, sloughs and reser-
voirs, sluggish
streams, and lentic waters.having sandy or clay bottoms.

Size: Maximum length about 5 cm. SRP maximum 49 cm, 1 g.

Reference:

Collette 1962. Etheostoma hopkinsi (Fowler) - Christmas darter Key Characters: Body elongate and slender. Spiny and soft portions of dorsal fin separated. Lateral line nearly complete. Snout pointed. Cheeks well scaled. More than 45 scales on lateral line. Prepectoral dark spot usually present. A very brightly colored darter especially during spawning. Can be confused with E. fricksium. SRP Distribution: Common. Collected from all major creeks except Lower Three Runs and the Salkehatchie. River. Rarely encountered in the Savannah River. Habitat and Habits: Clear streams with moderate to high* gradient over* a gravel substrate. Food is primarily aquatic insects and small crustaceans. Size: Maximum length about 8 cm. SRP maximum 7.4 cm, 3.5 g. Length-weight relationship (N = 24, r = 0.99) is In W= 3.20 (In TL) - 12.62.

References:

Bailey and Richards 1963, Fowler 1945.

118 Etheostoma inscriptum (Jordan and Brayton) - turquoise darter Synonym: Poecilichthys inscriptum (ANSP 1953) Key Characters: Snout forming a gentle curve,' :fl:::0m eye to tip of snout. Anal spines typically two, the first heavy and thick and appreciably thicker than 2nd spine. Frenum absent. SRP Distribution: A rare species below the Fall Line reported by ANSP in 1952 but not verified by any subsequent collection from SRP. Habitat and Habits: Clear streams with gravel substrate. Size: Maximum size about 6 cm. Etheostoma olmstedi Storer - tessellated darter Synonyms: Boleosoma sp., in part (Freeman 1954); Boleosoma nigrum (Fowler 1945); Etheostoma nigra (ANSP 1955). Key Characters: Body elongate and slender. Spiny and soft portions of dorsal fin separated. Lateral line complete. Snout very

blunt, mouth slightly oblique.

Sides with 9-11 "W" or "X" markings. Frenum absent (Fig. 22A). Dorsal surface with 6 saddle-like blotches. Preocular bar present. SRP Distribution: Abundant. Collected from major creeks on SRP except the Salkehatchie River. Rare in the Savannah River. Habitat and Habits: Clear streams with moderate to low gradient. Large sand to gravel substrate,is required. Deposits eggs on underside of rocks. Feeds on insects and entomostracans. Size: Maximum length 10 cm. SRP maximum 6.5 cm, 2.3 g. Length-weight rela-tionship (N = 13, r = 0.98) is In W= 2.89 (In TL) - 11.32.

Reference:

Cole 1967.

119 Etheostoma serriferum (Hubbs and Cannon) - sawcheek darter Synonyms: Boleosoma sp., in part (Freeman 1954). Key Characters: Body elongate and slender. Spiny and soft portions of dorsal fin separated. Lateral line incomplete and highly elevated. Snout blunt. Preopercle serrate. Base of caudal fin with vertical row of 4 *spots. SRP Distribution: Uncommon. Collected from Steel Creek and. Upper Three Runs. Habitat and Habits:

Clear, fast moving. waters with sandy to gravelly bottoms.

Voracious feeders on small insects and crustaceans. Size: Maximum length 7 cm. SRP maximum 5.8 cm, 1.49 g. Length-weight rela-tionship (N = 11, r = 0.90) is In W= 3.58 (In TL) - 14.18.

Reference:

Collette 1962. Perca flavescens (Mitchill) - yellow perch Key Characters: Spiny and soft portions of dorsal fin separated. Mouth

large, maxilla extending to middle of eye.

Pseudobranch well developed. Preopercle strongly serrate. Body with orange fins and dark vertical bars. SRP Distribution: Common. An introduced species in the Savannah River, common in the river and swamp and collected in Par Pond and all major. creeks. Habitat and Habits: Inhabits bayous, sluggish streams, rivers and lakes. Requires vegetation as a medium for egg incubation. Feeds primarily on fish. Size: Maximum length about 40 cm. SRP maximum 29 cm, 318 g. Length-weight relationship (N = 123, r = 0.98) is In W= 3.19 (In TL) - 12.44. Percina nigrofasciata (Agassiz) - blackbanded darter Synonyms: Hadropterus nigrofasciatus (Freeman 1954); Percina nigrofasciatus (Fowler 1945).

120 Key Characters: Spiny and soft portions of dorsal fin separated. Area of anal fin usually as large as area of soft dorsal fin.

  • Mouth terminal.

Sides with 10-11 diamond shaped blotches along each side. Frenum present (Fig. 22B). Spiny, enlarged scale(s) between pelvic fins (Fig. 21A). SRP Distribution: Common. Collected from major creeks except the Salke-hatchie River. Rare in the Savannah River. Habitat and Habits: Clear, fast moving streams with gravel and rubble bottom types. Food is primarily aquatic insects. Size Maximum length about 7 em.

References:

Crawford 1956, Fowler 1942, Mathur 1973. MULLET FAMILY - MUGILIDAE A single representative, the striped

mullet, Mugil
cephalus, of the family Mugilidae, occurs on the SRP.

Although mullet are considered marine they migrate upstream and are fonnd in the Savannah River and major tribu-taries. Mullet can be readily identified by their weak mouths, small 4-spined dorsal fin separated from the soft rayed portion, and high fin location of the pectorals. The mouth is an inverted "V". Mullets have adipose eyelids like herring. Mugil cephalus Linnaeus - striped mullet Key Characters: Adipose eyelid. Dorsal fin separated; four spines followed by soft rayed portion. Pectorals high on body. Body dark dorsally to sil-very below and stout. . Mouth an inverted "V". May be confused with atheri-nids except* atherinids have dorso-ventrally flattened heads and larger mouths.

,121 SRP Distribution: Uncommon. Found throughout the year in small numbers in the Savannah River, the intake canals, and the river swamp. Also collected from Lower Three Runs and below the confluence of Steel Creek and Pen Branch. Habitat and Habits: Open waters of large rivers. Size: Maximum length about 60 cm. SRP maximum 43 cm, 1100 g. Length-weight relationship (N = 19, r = 0.98) is In W=3.38 (In TL) - 13.54.

Reference:

Dahlberg 1975. ORDER - PLEURONECTIFORMES SOLE FAMILY - SOLEIDAE The family Soleidae is a family of small flatfishes normally associated with ~arine ecosystems; however, they also venture upstream to the SRP in the Savannah River. Members of this family have eyes on the right side of the head (Fig. 11). ,straight. Mouth is small and curved. Lateral line present and Trinectes maculatus (Bloch and Schneider) - hogchoker Key Characters: Pectoral fins absent. Seven or eight cross bars on a dorsal surface, ventral surface is light. Body flat and small (Fig. 11). SRP Distribution: Uncommon. Found on sandbars in the Savannah River. Enters intake canals, Steel Creek, Lower Three Runs Creek, and the mouth of Pen Branch. Habitat and Habits: Inhabits slow moving waters of shallow to medium depth, with sandy bottoms. Size: Maximum length about 15tm. SRP maximum 10.5 cm, 31 g. Length-weight relationship (N = 12, r = 0.99) is In W= 2.97 (in TL) - 10.44.

Reference:

Dahlberg 1975.

124 Glossary Adipose eyelid: a transparent tissue that covers part of the eyeball. Adnate adipose fin: a fleshy, median dorsal structure behind the dorsal fin that is attached to the caudal fin.

      • Anadromous:

living at sea and spawning in freshwater. Barbel: a fleshy, tactile protuber~nce in the form of a flap or threadlike structure. Braided: division of as*tream/river* cha"nnel into numerous channels. Branchiostegal ray: a' long, curved;'*, and often flattened bone supporting the membrane below the gill cover.* Catadromous: spawning in oceans and living in freshwater. Caudal peduncle: the slender section of the fish supporting the tail fin behind the anal fin. Ctenoid: Cycloid: a type of scale bearing small spines on the posterior surface. a type of scale, roughly circular, without small spines on the posterior surface. Character index: an arithmetic determination made by subtracting the number of gill rakers from the number of anal rays. Emarginate: ma~gin notched. Entire: margin smooth, not notched. Falcate: a fin shape that is sickle-shaped or concave margin. Fin insertion: the anterior-most or uppermost end of a fin base. Frenum: a piece of tissue connecting the upper lip with the snout and pre-venting protrusion of the upper lip. Ganoid scale: a type of hard fish scale covered by an enamel-like substance. Gibbous-shaped: round, flat body appearance.

125 Gill rakers: - slender-rod-like to blunt,..nob-like projections on the inner edge of a gill arch (structure supporting gill; Fig. 20). Gill isthmus: the ventral* surface of a fish between.the two gill chambers. Heterocercal: a type of tail in which the vertebrae curve upward into the

  • large lobe of the caudal fin.

Homocercal: a type of tail in which the vertebrae end at the caudal fin and the lobes are about equal. Included: the condition in which the upper jaw extends beyond the lower jaw. Jugular: pertaining to the throat region. Keel: a raised ridge on the body. Lacustrine: standing water. Lentic: standing water. Limnetic larval stage: early life history stage spent in waters away from the shoreline. Lotic: running water. Maxilla (maxillary): the posterior-most bone on the upper jaw; the pre-maxilla is the anterior bone. Melanophore: a black pigment cell. Naked: scaleless. Nape: dorsal area between the skull and insertion of the dorsal fin. Operculum (opercle): the gill cover; divided into a preopercle and opercle (Fig. 7). Palatine teeth: teeth on the anterior ventral surface of the skull near the naris. Peritoneum: the lining of the body cavity; may be light or dark. Pharyngeal teeth: teeth in the throat region, usually 5th pharyngeal arch. Plica (pl. plicae): fleshy, folded lips of fishes.

126 Predorsal scales: a row of scales crossing the midline between the origin of the dorsal fin and the posterior-most point of the skull. Preoperculomandibular pores: small pores extending in front of the operculum and onto the lower jaw. Pseudobranch: a structure resembling a gill on the inner surface and upper edge of the gill cover. Serrae (serra sing.): tooth-like structures along an edge.

127 Acknowledgments Field research and much of the manuscript preparation was carried out under Contract EY-76-C-09-0819 between the University of Georgia and the Department of Energy. Two major field and compilation efforts were supported by the Savannah River National Environm:ental Research Park Program. The final manuscript preparation was aided by the College of Forestry, Wildlife and Range Sciences, University of Idaho, Moscow. An intensive field effort was made possible by the cooperation of numer-ous individuals associated with the Savannah River Ecology Laboratory. Special thanks are extended to Dr. Janalee Caldwell and Joseph R. McAuliffe for their tireless efforts. Sherry E. Williams, C. T. Garten, J. C. Murphy, B. C. Moore, and Tim Smith aided in field collecting. Drs. J. G. Wiener and Don Schure and Ms. Judith Greene-McLeod graciously shared their unpublished data on a number of fish collections. Particular thanks go to Dr. J. Whitfield Gibbons who provided encourage-ment and assistance throughout the study as well as field data on several species and habitats. Dr. W. R. Taylor of the National Museum of Natural

History, assisted in the identification and construction of the key for Ictalurids.

Dr. Edgar N. Gramblin, also of the National Museum of Natural

History, provided invaluable assistance in locating Dr.

Freeman I s earlier collection from the SRP. Messrs. R. F. Frietsche and R. D. Miracle of the Savannah River Laboratory significantly advanced our knowledge of the Savan-nah River i chthyofauna and aided in the identification of specimens and construction of the cyprinid keys. Ms. Jean Coleman made all the drawings. Ms. Tonya Willingham typed numerous draft copies of the text. Ms. Janell

Gregory, Karen K.

Patterson, and J. Whitfield Gibbons provided editorial assistance and helped with manuscript preparation. The typing of Mrs. Bar-bara Schoeffler also is appreciated.

130

131

Blair, W. F., A. P. Blair, P. Brodkorb, F. R. Cagle, and G. A. Moore.

1968. Vertebrates of the United States. McGraw-Hill, Incorporated, New York. 616 p. (a key to the fishes of the contiguous United States; illustra-tions of some SRP species). Brown, J. L. 1957. A key to the species and subspecies of the cyprinodont genus Fundulus in the United States and Canada east of the continental divide. Journal Washington Academy of Science 47(3):69-77. 1958. Geographic variation in southeastern populations in the cyprinodont fish Fundulus notti (Agassiz). American Midland Naturalist 59:477-488.

Burbidge, R.

G. 1974. Distribution, growth, selective feeding, and energy transformations of the young-of-the-year blueback herring, Alosa aesti-valis (Mitchill), in the James River, Virginia. Transactions of the American Fisheries Society 103(2):297-311. Carlander, K. D. 1969. Handbook of freshwater fishery biology, Volume 1. Iowa State University Press, Ames. 752 p. (useful morphometric and life history data on many SRP fishes). 1977. Handbook of Freshwater Fishery Biology, Volume 2. Iowa State University Press, Ames (useful morphometric and life history data on SRP sunfishes). Cherry, D. S., R. K. Guthrie, J. H. Rodgers, Jr., J. Cairns, Jr., and K. L. Dickson. 1976. Responses of Mosquitofish (Gambusia affinis) to ash effluent and thermal stress. Transactions of the American Fisheries Society 105 (6): 686-694. (mosquitofish studies from Beaverdam Creek).

Clugston, J.

P. 1973a. The effects of heated effluents from a nuclear reactor on species diversity, abundance, reproduction, and movement of

132 fish. Ph.D. Dissertation University of

Georgia, Athens.

104 p. (the only study of the complete ichthyofauna of Par Pond).

Clugston, J.

P. 1973b. The fishes of Lower Three Runs Creek and the Par Pond reservoir system of the Savannah River

Plant, South Carolina.

Savannah River Laboratory, Aiken, S. C. TID-26216. 12 p. Cole, C. F. 1967. A study of the eastern Johnny Darter, Etheostoma olmstedi Storer (Teleostei, Percidae). Chesapeake Science 8:28-51.

Collette, B.

B. 1962. The swamp darters of the subgenus Hololepis (Pisces, Percidae). Tulane Studies in Zoology 9(4):115-212. (Etheostoma fusi-

forme,

~. serriferum).

Crawford, R.

W. 1956. A study of the distribution and taxonomy of the percid fish Percina nigrofasciata (Agassiz). Tulane Studies in Zoology 4(1):1-55.

Dahlberg, M.

D. 1975. Guide to the coastal fishes of Georgia and nearby states. University of Georgia

Press, Athens.

187 p. (information regarding the marine and anadromous fishes of SRP).

Dahlberg, M. D.,

and D. C. Scott. 1971a. The freshwater fishes of Georgia. Bulletin Georgia Academy of Science 29 (1): 1-64. (an important work on the distribution of fishes in Georgia, including the Savannah River). 1971b. Introductions of freshwater fishes in Georgia. Bulletin Georgia Academy of Science 29(4):245-252. (documents the knownintro-duction of sixSRP fishes into the Savannah River).

Douglas, N.

H. 1974. Freshwater fishes of Louisiana. Claitor's Publishing Division. Baton Rouge. 443 p.

Dudley, R.

G., A. W. Mullis, and J. W. Terrell. 1977. Movements of adult striped bass (Morone saxatilisin the Savannah River, Georgia. Trans-actions of the American Fisheries Society 106(4):314-322.

133 Dupont, S. P. 1976. The behavior of largemouth bass (Micropterus salmoides) in a reservoir receiving a heated effluent. M.S. Thesis, University of Georgia.

Eddy, S.

1957. How to know the freshwater fishes. W. C. Brown Company, Dubuque, Iowa, 253 p. 1969. How to know the freshwater fishes. William C. Brown Com-pany, Dubuque, Iowa. 286 p. (a useful key with illustrations to iden-tify most SRP species).

Esch, G. W.,

T. C. Hazen; R. V. Dimock, Jr. and J. W. Gibbons. 1976. Ther-mal effluent and the epizootiology of the ciliate Epistylis and the bac-terium Aeromonas in association with centrarchid fish. Transactions of the American Microscopic Society 95:687-693. Eure, H. E. 1974. Studies on the effects of thermal effluent on the popula-tion dynamics of helminth parasites of the largemouth bass, Micropterus salmoides. Ph.D. Dissertation, Wake Forest University, Winston-Salem, North Carolina. 95 p. 1976a. Seasonal abundance of Neoechinorhynchus cylindratus taken from largemouth bass (Micropterus salmoides) in a heated reser-voir. Parasitology 73:355-370. 1976b. Seasonal abundance of Proteocephalus ambloplitis (Ces-toidea:Proteocephalidae) from largemouth bass living in a heated reser-voir. Parasitology 73:205-212. Eure, H. E. and G. W. Esch. 1974. Effects of thermal effluent on the popu-lation dynamics of Helminth parasites in largemouth bass. Pages 207-215* in J. W. Gibbons and R. R.

Sharitz, (editors) Thermal Ecology.

Atomic Energy Commission Symposium Series (CONF-73050S).

134 Falke, J. D. and M. H. Smith. 1974. Effects of thermal effluent on fat content of the mosquitofish. Pages 100-108 in J. W. Gibbons and R. R.

Sharitz, (editors) Thermal Ecology.

Atomic Energy Commission Symposium Series (CONF-730505).

Ferens, M.

C. and T. M. Murphy. 1974. Effects of thermal effluents on populations of mosquitofish. Pages 237-245 In J. W. Gibbons and R. R.

Sharitz, (editors) Thermal Ecology.

Atomic Energy Commission Symposium Series (CONF-730505).

Forbes, S.

A. and R. E. Richardson. 1920. The fishes of Illinois. Second Edition. Illinois Natural History Survey. Circular 3.

Fowler, H.

W. 1920. Description of a new cyprinid fish (Notropis stonei) with notes on other fishes obtained in the United States. Proceeding of the Academy of Natural Sciences of Philadelphia. Pages 391-393. (a redescription of Notropis hypselopterus under synonym~. stonei). Fowler, H. W. 1935. Notes on South Carolina freshwater fishes. Contribu-tions from Charleston Museum No.7. Pages 6-28. (contains illustra-tions of 27 SRP species). 1942. Description of six new fresh-water fishes (Cyprinidae and Percidae) from the southeastern U. S. Nat. Acad. Natural Sci. of Phila-delphia. 1945. A study of the fishes of the southern piedmont and coastal plain. Academy of Natural Sciences of Philadelphia. Monograph No.7. (the original description of Etheostoma hopkinsi; many illustra-tions of SRP fishes).

Freeman, H.

W. 1952. New distributional records for fishes of the Savannah River Basin, South Carolina. Copeia 4:269.

135 Thermal alteration of aquatic 1974. 1954. Fishes of the Savannah River Operations Area. University of South Carolina Publication Series III. Biology 1(3): 117-158. (the pre-operational baseline study of SRP stream fishes). 1958. Fish Species of Lower Three Runs Creek on Savannah River Plant (Unpublished repo~t U. S. Atomic Energy Commission, 35 p.). Frietsche, R. A., R. D.

Miracle, and R.

W. McFarlane. 1979. Larvae and juveniles of the brook silverside, Labidesthes sicculus.

p. 189-193 in R.

Wallus & C. W. Voitlander, Freshwater Larval Fishes, Tenn. Valley Author., Norris, TN.

Gibbons, J.

W., J. T. Hook and D. L. Forney. 1972. Winter responses of largemouth bass to heated effluent from a nuclear reactor. Progressive Fish Culturist 34(2):88-90.

Gibbons, J.

W. and D. H. Bennett. 1973. Abundance and local movement of largemouth bass (Micropterus salmoides) in a reservoir receiving heated effluent from a reactor. Pages 524-427 in D. J. Nelson. (editor), Proceedings of the 3rd National Symposium of Radioecology. (CONF-710501-P1).

Gibbons, J.

W. and R. R. Sharitz. ecosystems. American Scientist 62:660-670. 1981. Thermal ecology:,Environmental teachings at a nuclear reactor site. BioScience 31:293-298.

Gibbons, J.

W., R. R.

Sharitz, and 1.

L. Brisbin. 1980. Thermal ecology research on the Savannah River Plant: A review. Nuclear Safety 21: 367-379. Gibbons, J. W., R. R. Sharitz, F. G. Howell, and M. H. Smith. 1975. Ecology of artificially heated streams, swamps and reservoirs on the Savannah River Plant. IAEA-SM-187/13, Vienna. Pages 389-400.

136 Gibbons, J. W., D. H. Bennett, G. W. Esch, and T. C. Hazen. 1978. Effects of thermal effluent on body condition of largemouth bass. Nature 247: 470-471. Giesy, J. P. and J. G. Wiener. 1977. Frequency distribution of trace metal concentrations in five freshwater fishes. Transactions of the American Fisheries Society 106:393-403. (Alosa aestivalis, Notemigonus crysoleu-

cas, Notropis petersoni, Esox niger, Lepomis macrochirus, Labidesthes sicculus.
Godwin, W.

F. 1968. The shad fishery of the Altamaha

River, Georgia.

Georgia Marine Fisheries Division Contribution Series No.8. 39 p. Gold,D. D., D. C. Scott, A. Hirsch, C. C. Ruchhoft, and L. R. Setter. 1954. Interim Report on the Savannah River Studies. U. S. Department of

Health, Education and Welfare.

U. S. Public Health Service. Cincin-nati, Ohio, 257 p. (a preoperational survey of Savannah River fishes).

Goodyear, C.

P. 1970. Terrestrial and aquatic orientation in the starhead topminnow, Fundulus notti. Science,168:603-605. 1973. Learned orientation in the predator avoidance behavior of mosquitofish Gambusia affinis. Behavior 45:191-224.

Goodyear, C. P.,

and C. E. Boyd. 1972. Elemental composition of largemouth bass (Micropterus salmoides). Transactions of the American Fisheries Society 101:545-547.

Goodyear, C. P.,

C. E. Boyd, and R. J. Beyers. 1972. Relationships between primary productivity and mosquitofish (Gambusia affinis) production in large microcosms. Limnology and Oceanography 17:445-450.

Goodyear, C.

P., and D. E. Ferguson. 1969. Suncompass orientation in the mosquitofish, Gambusia affinis. Animal Behavior 17:639-640.

137

Goodyear, C.

P. and D. H. Bennett. 1979. Sun compass orientation of imma-ture bluegill. Transactions of the American Fisheries Society 108:555-559. Harvey, R. S. 1964. Uptake of radionuclides by fresh water algae and fish. Health Physics 10:243-247. (Lepomis macrochirus, Micropterus salmoides, Ictalurus natalis). Hildebrand, S. F. 1923. Annotated list of fishes collected in the vicinity of Augusta, Georgia, with description of a new darter. Bulletin U. S. Bureau Fisheries Volume 39:1-8.

Hogan, D.

C. 1977. Distribution and relative abundance of prey fish in a reservoir receiving a heated effluent. M. S. Thesis. University of

Georgia, Athens.

(Alosa aestivalis, Notropis petersoni, Lepomis auri-tus, Lepomis macrochirus

Holland, W. E.,

M~ H. Smith, J. W. Gibbons, and D. H. Brown. 1974. Thermal tolerances of fish from a reservoir receiving heated effluent from a nu-clear reactor. Physiological Zoology 47: 110-118. (Lepomis macrochi-rus.

138 Humphries, R. L. 1965. A study of the movements of channel catfish Icta-luris lacustris punctatus, in the Savannah River and one of its tribu-taries within the AEC Savannah River Operations area. Institute of Ra-diation Ecology. University of

Georgia, Athens.

TID-21791. 53 p. Jenkins, R. E. 1970. Systematic studies of the catostomid fish tribe Moxo-stomatini. Ph.D. Dissertation. Cornell University. University Micro-films 71-14, 641, 818 p. (Hypentelium, Moxostoma). Jenkins, R. E., L. A. Revelle, and T. Zorach. 1975. Records of the black-banded sunfish, Enneacanthus chaetodon, and comments on the southeastern Virginia .freshwater ichthyofauna. Virginia Journal of Science 26 (3): 128-134.

Johnson, S.

R. 1976. The food habits of bluegill, Lepomis macrochirus, and largemouth bass, Micropterus salmoides in reservoirs receiving heated effluent from a nuclear reactor. M.S. Thesis. University of Georgia, Athens. Jordan, D. S. and A. W. Brayton. 1878. Contributions to the North American Ichthyology. Based primarily on the collections of the United States National Museum. III. A. On the distribution of the fishes of the Allegheny Region of South Carolina, Georgia, and Tennessee with descrip-tions of new and little known species. Bulletin United States National Museum 12:1-:95.

Langley, T.

M. and W. L. Marter. 1973. The Savannah River Plant site. Savannah River Laboratory,

Aiken, South Carolina DP-1323.

175 p. (physical description of the SRP and its biota). Lattimore, R. E. and J. W. Gibbons. 1974. Body condition and stomach con-tents of fish inhabiting thermally altered areas. American Midland Naturalist 95:215-219. (Lepomis

auritus, L.

punctatus, Enneacanthus gloriosus).

The migrations of the shad. Scientific American 139

Leggett, W.

C. 1973. 228(3):92-98. Loesch, J. G. and W. A. Lund, Jr. 1977. A contribution to the life history of the blueback herring, Alosa aestivalis. Transactions of the American Fisheries Society 106(6):583-589. Loyacano, H. A., Jr. 1975. A list of freshwater fishes of South Carblina. South Carolina Agricultural Experiment Station. Clemson University, Clemson, South Carolina Bulletin No. 580. 8 p. Mathur, D. 1973. Some aspects of the life history of the blackbanded dar-

ter, Percina nigrofasciata (Agassiz) in Halawakee
Creek, Alabama.

American Midland Naturalist 89(2):381-393. McFarlane, R. oW. 1976. Fish diversity in adjacent ambient, thermal and post-thermal freshwater streams. Pages 268-271 in G. W. Esch and R. W. McFarlane, (editors). Thermal Ecology II.

Energy, Research and De-velopment Administration Symposium Series 40 (CONF-750425).

(SRP stream fishes). McFarlane, R. W., B. C. Moore and S. E. Williams. 1976. Thermal tolerance of stream cyprinid minnows. In: G. W. Esch and R. W. McFarlane (Eds.), Thermal Ecology II. ERDA Symp. Ser. (CONF-750425). (Notropis cumming-

sae,

~. lutipinnis, Semotilus at~omaculatus). McFarlane, R. W., R. F. Frietsche and R. D. Miracle. 1978. Impingement and entrainment of fishes at the Savannah River Plant. E. I. duPont de Nemours and Co. DP-1491. Aiken, South Carolina. 68 p. 1979. Community structure and differential impingement of Savannah River Fishes. Proceedings of the Annual Conference of the South Eastern Association of Fish &Wildlife Agencies 33:628-638.

Ecological com-Journal of the 140

Murphy, J.

C., C. T.

Garten, Jr.,M.

H.

Smith, and E.

A. Standora. 1976. Thermal tolerance and respiratory movement of bluegill from two popula-tions tested at different levels of acclimation temperature. Pages 145-147 in G. W. Esch and R. W. McFarlane, (editors). Thermal Ecology II. Energy, Research and Development Administration Symposium Series 40 (CONF-750425). Murphy, J. C. and J." W. Gibbons. 1977. Bibliography of aquatic and thermal studies conducted on the Savannah River Plant. Revision I. Savannah River Ecology Laboratory, Aiken, "South Carolina. 26 p.

Parker, E.

D., M. R. Hirshfield and J. W. Gibbons. 1973. parisons of thermally affected aquatic environments. Water Pollution Control Federation 45(4):726-733. Patrick, R., J. Cairns, Jr.' and S. S. Roback. 1967. An ecosystematic study of the fauna and flora of the Savannah River. Proceedings of the Acad-emy of Natural SCi~ncesof Phila'delphia 118(5): 109-407. (a ten year review of the ANSP collections). Pflieger, "W. L.1975." The fishes of Missouri. Missouri DepartmEint of Conservation. 343p. (comprehensive review of Missouri fishes).

Quinn, T.,

G. W."Esch, T. C. Hazen,and'J: W. Gibbons"~ 19"78. Long range movement and homing by" largemouth bass (Micropterus salmoides in ther-mally altered reservoir. Copeia. 3 :"542-"545. "~ichardson; J. 1836." Fauna Boteali-Americana, or the zoology of the north-ern parts of British America, containing desc'riptions of the obj ects of "natural"" history "c~llected on the late north~rn land expeditions, under the c"ommand of Sir John Franklin, R.N. London and Norwich, Volume 3, "the Fish.

141

Ricker, W. E.

1973. Linear regression in fishery research. Journal of the Fisheries Research Board of Canada 30:409-434. Rivas, L. R. 1966. The taxonomic status of the cyprinodontid fishes Fundu-Ius notti and F. lineolatus. Copeia. 2:353-354. Siler, J. R. 1975. The distribution of fishes in two cooling reservoirs with different heat loads. M.S. Thesis. University of Georgia, Athens. (Par Pond; Micropterus salm01des, Lepomis macrochirus, Ictalurus ~- cephalus, Erimyzon sucetta). Siple, G. E. 1967. Geology and ground water of the Savannah River Plant and vicinity South Carolina. 1841. 113 p. Geological Survey Water-Supply Paper. No. Smith, L. D. 1968. Notes on the distribution, relative abundance and growth of juvenile anadromous fish in the Altamaha River system, Georgia, with specific reference to striped bass, Roccus saxatilis (Walbaum). Georgia Marine Fisheries Division Contribution Series No.1. 22 p. Smith, M. H. and S. L. Scott. 1975. Thermal tolerance and biochemical poly-morphism of immature largemouth bass Micropterus salmoides Lacepede. Bulletin of the Georgia Academy of Sciences 34:180-184. Smith-Vaniz, W. F. 1968. Freshwater fishes of Alabama. Auburrt University Agricultural Experiment Station (information' on SRP species and photo-graphs of SRP specimens)~

Smoak, C. H., Jr.'

1959. Some considerations in the upper thermal tolerance on Gambusia affinis holbrooki (Girard) in the Savannah River Plant area. South Carolina Academy of Sciences.

p. 44-53.
Street, M.

W. 1969a. Fecundity of the hickory shad in the Altamaha River, Georgia. Georgia Marine Fisheries Division Contribution Series No. 14. 11 p.

142 1969b. Fecundity of the blueback herring in Georgia. Georgia Marine Fisheries Division Contribution Series No. 17. 15 p.

Street, M.

W. and J. G. Adams. 1969. Aging of hickory shad and blueback herring in Georgia by the scale method. Georgia Marine Fisheries Divi-sion Contribution Series No. 18. 13 p. Tilly, L. J. 1975. Changes in water chemistry and primary productivity of a reactor cooling reservoir (Par Pond). Pages 394-407 in Mineral Cycling in Southeastern Ecosystems. F. G.

Howell, J.

B.

Gentry, and M.

H.

Smith, editors.

Energy Research Development Administration Symposium Series (CONF-740513). Trautman, M. B. 1957. The fishes of Ohio. The Ohio State University Press. 683 p.

Vaughn, T.

L. 1967. Fecundity of the American shad in the Altamaha River system. Georgia Marine Fisheries Division Contribution Series No.3. 9 p.

Wells, L.,

and R. House. 1974. Life history of the spottail shiner (No-Report 78. Whitworth, W. R. River Plant. tropis hudsonius in southeastern Lake Michigan, the Kalamazoo River, and western Lake Erie. Bureau Sport Fisheries and Wildlife Research 10 p. 1969. Unpublished list of fishes from the Savannah University of Connecticut, Storrs.

Wiener, J.

G. and M. H. Smith. 1981. Studies of Aquatic and Terrestrial Environments of the Savannah River Plant, South Carolina: A Biblio-graphy. SRO-NERP-7. Savannah River Ecology Laboratory, Aiken, SC. 131 pp. Wiri.n, H. E. 1958. Comparative reproductive behavior and ecology of fourteen species of darters (Pisces Percidae). Ecological Monographs 28(2): 155-191.

143 Yardley, D., J. C. Avise, J. W. Gibbons and M. H. Smith. 1974. Biochemical genetics of sunfish. III. Genetic subdivision of fish populations inhabiting heated waters. Pages 255-263 in J. W. Gibbons and R. R.

Sharitz, (editors).

Thermal Ecology. Atomic Energy Commission Sympo-sium Series (CONF-730505). (Gambusia

affinis, Lepomis macrochirus, Micropterus salmoides.

Yerger, R. W. and K. Relyea. 1968. The flatheaded bullheads (Pisces: Ictaluridae) of the southeastern United States, and a new species of Ictalurus from the Gulf Coast. Copeia. 2:361-384. (description of Ictalurus brunneus as distinguished from I. platycephalus, includes data from Savannah River specimens).

144 Acantharchus pomotis 99,104 Acipenser oxyrhynchus 55 Acipenseridae 55 Acipenseriformes 55 aestivalis, Alosa 58,59 affinis, Gambusia 94 Alosa aestivalis 58,59 mediocris 58,59,60 sapidissima 58,59,61 Amblyopsidae 90 American eel 57,58 American shad 61,59,58 americanus, Esox 64 Amia calva 57 Amiidae 57 Amiiformes 57 Anguilla rostrata 57,58 Anguillidae 57 Angilliformes 57 anisurum, Moxostoma 79,82 annularis, Pomoxis 99,112 Aphredoderus sayanus 91 INDEX Aphredoderidae 91 Atherinidae 95,120 Atheriniformes 92 Atlantic needlefish 92 Atlantic sturgeon 55 Atractosteus 55 atromaculatus Semotilus 66,78 auritus, Lepomis 104,106,i23 banded pygmy sunfish 99,105 bannerfin shiner 70,76 bass, largemouth 19,98,100,111 bass, striped 96,97 bass, white 96,97 Belonidae 92 blackbanded darter 114,119 blackbanded sunfish 99,105 black crappie 99,112 blueback herring 58,59 bluehead chub 66,73 black bullhead 123 bluegill 104,109 bluespotted sunfish 99,106 Boleosoma 118,119 nigrum 118

bowfin 57 brook silverside 95 Boleichthys fusiformis 116 brown bullhead 85,87 brunneus, Ictalurus 85,87 bullhead flat 85,87 snail 85 brown 85,87 yellow 85,86 calva, Amia 57 caprodes, Percina 123 carp 66,71 carpio, Cyprinus 66,71 Carpiodes carpio 123 cyprinus 79,80 velifer 12.3 Catfish 83 channel 83,88 white 83,86 flathead 83,90 Catostomidae 78 catus, Ictalurus 83,86,88 cavefish 90 Centrarchidae 98 ) 145 chaetodon, Enneacanthus 99,105 chain pickerel 64,65 chalybaeus, Notropis 70,73 channel catfish 83,88 Chaenobryttus coronatius 108 Chologaster cornuta 90,91 Christmas darter 116,117 chrysops, Morone 96,97 chub creek 66,78 rosyface 66,72 bluehead 66,73 chubsucker creek 79,80 lake 81,82 Clupeidae 58,59 Clupeiformes 58 coastal shiner 70,77 Coosa shiner 122 coosae, Micropterus 123 cornuta, Chologaster 90,91 crappie black 99,112 white 99,112 creek club 66,78 Centrarchus macropterus 99,104 cepedianum, Dorosoma 58,59,62 cephalus, Mugil 120 creek chubsucker 79,80 crysoleucas, Notemigonus 66,72 cummingsae, Notropis 71,74 cyanellus, Lepomis 100,107

146 Cyprinidae 65 Cypriniformes 65 Cyprinodontidae 93 Cyprinus carpio 66,71 cyprinus, Carpiodes 79,80 darter blackbanded 114,119 Christmas 116,117 tessellated 114,118 turquoise 116,118 sawcheek 114,119 Savannah 116 swamp 114,116 dollar sunfish 100,109 Dorosoma cepedianum 58,59,62 petenense 58,59,62 dusky shiner 71,74 eastern mudminnow 63 eel American 57, 58 Elassoma zonatum 99',105 emiliae, Notropis 69,74 Enneacanthus chaetodon 99,105 gloriosus 99,106 Erimyzon oblongus 79,80 sucetta 80,81 Esocidae 63 Esox niger 64,65 americanus 64 Etheostoma fricksium 116,117 fusiforme 114,116 barratti 116 hopkinsi 116,117 nigra 118 inscriptum 116,118 olmstedi 114,118 serriferum 114,119 flat bullhead 85,87 flathead catfish 83,90 flavescens, Perca 113,114,119 flier 99,104 Florida gar 56 fricksium, Etheostoma 116,117 Fundulus 19 lineolatus 93 Fundulus notti 93 Fundulus dispar lineolatus 93 fusiforme, Etheostoma 114,116 Gambusia 19 affinis 94 G. holbrooki 94 gar 55 Florida 56 longnose 55,56 gibbosus, Lepomis 100,107,110 gizzard shad 58,59,62

gloriosus, Enneacanthus 99,106 golden shiner 66,72 green sunfish 100,107 gulosus, Lepomis 100,108 gyrinus, Noturus 85,88 herring, blueback 58,59 Hadropterus nigrofasciatus 119 highfin carpsucker 123 hickory shad 58,59,60 hogchoker 121 hogsucker, northern 79,81 hopkinsi, Etheostoma 116,117 holbrooki, Gambusia affinis 94 Hololepis barratti 116 hudsonius, Notropis 70,75 Huro floridana 111 Hyb0gnathus nuchalis 69,71 Hybopsis rubrifrons 66,72 Hybopsis bellicus 73 Hybopsis leptocephala 73 Hydrophlox 73 chalybaeus 73 lutipinnis 76 Hypentelium nigricans 79,81 hypselopterus, Notropis 70,75 147 Ictaluridae 83 Ictalurus brunneus 85,87 catus 83,86,88 melas 123 i.li:it'aTis 85,86 nebulosus 85,87 platycephalus 85,86,87 punctatus 83,86,88 Icthelis macrochira 109 inscriptum, Etheostoma 116,118 insignis, Noturus 85,89 ironcolor shiner 70,73 killifish 93 Labidesthes sicculus 95 lake chubsucker 80,81 largemouth bass 19,98,100,111 leedsi, Notropis 70,76 Lepisosteidae 55 Lepisosteus 55,92 oculatus 122 osseus 55,56 platyrhincus 56,122 Lepibema chrysops 97 Lepomis auritus 104,106,123 cyanellus 100,107 gibbosus 100,107,110 gulosus 100,108 macrochirus 104,109 marginatus 100,109,123

148 megalotis 123 microlophus 100,107,108,110 punctatus 100,110 leptacanthus, Not-urus 85,89 leptocephalus, Nocomis 66,73,122 lined topminnQw 93. lineolatus, Fundulus 93 logperch 123 longear sunfish 123 longnose gar 55,56 lutipinnis, Notropis 70,76 macrochirus, Lepo~is 104,109 macropterus, Centrarchus 99,104 maculatus, Notropis 69,77 maculatus, Trinectes 121,123 madtom margined 85,89 tadpole 85,88 speckled $5,89 marginatus, Lepomis 100,109,123 marina, Strongylura 92 margined madtom 85,89 mediocris, Alosa 58,59,60 melanops, Minytrema 79,82 Mesogonistus c. chaetodon 105 microlophus, Lepomis 100,107,108,110 Micropterus coosae 123 salmoides 98,100,111 minnow 65 silvery 69,71 pugnose 69,74 Minytrema melanops 79,82 Monrone chrysops 96,97 .saxatilis 96,97 mosquitofish. 94 Moxostoma anisurum 79,82 mudminnow, eastern 63 mud sunfish 99,104 Mugil cephalus 120 Mugilidae 120 mullet, striped 120 Myrophis punctatus 122 natalis, Ictalurus 85,86 nebulosus, Ictalurus 85,87 needlefish, Atlantic 92 niger, Esox 64,65 nigricans, Hypentelium 79,81 nigrofasciata, Percina 114,119,123 nigromaculatus, Pomoxis 99,112 niveus, Notropis 69,77

Nocomis leptocephalus 66,73,122 micropogon 122 Nocomis bellicus 73 northern hogsucker 79,81 Notemigonus crysoleucas 66,72 Notropis ch~lybaeus 70,73 cummingsae 71,74 emiliae 69,74 hudsonius 70,75 hypselopterus 70,75 hypselopterus stonei 75 leedsi 70,76 lutipinnis 70,76 maculatus 69,77 niveus 69,77 petersoni 70,77,122 spilopterus 122 stonei 75 xaenocephalus 122 Noturus gyrinus *85,88 insignis 85,89 leptacanthus 85,89 marginatus 89 nuchalis, Hybognathus 69,71 oblongus, Erimyzon 80,79 Opsopoeodus emiliae 74 olivaris, Pylodictus 83,90 olmstedi, Etheostoma 114,118 osseus, Lepisosteus 55;56 oxyrhynchus, Acipenser 55 149 Perca flavescens 113,114,119 P. chrysops 97 perch pirate 91 yellow 113,114,119 Percichthyidae 96 Percidae 113 Perciformes 96 Percina caprodes 123 nigrofasciata 114,119,123 nigrofasciatus 119 Percopsiformes 90 petenense, Dorosoma 58,59,62 petersoni, Notropis 70,77,122 pickerel chain 64,65 redfin 64 pike 63 Pimelodus insignis 89 pirate perch 91 platycephalus, Ictalurus 85,86,87 platyrhincus, Lepisosteus 56,122 Pleuronectiformes 121 Poeciliidae 94 Poecilichthys fricksia 116 inscriptum 118 pomotis, Acantharchus 99,104 Pomotis gibbosus 107

150 Pomoxis annularis 99,112 nigromaculatus 99,112 pugnose minnow 69,74 pumpkinseed 100,107 punctatus, Ictalurus 83,86,88 punctatus, Lepomis 100,110 pygmaea, Umbra 63 pygmy sunfish (banded) 99,105 Pylodictus olivaris 83,90 quillback 79,80 redbreast sunfish 104,106 redear sunfish 100,110 redeye bass 123 redfin pickerel 64 redhorse, silver 79,82 river chub 122 river carpsucker 123 Roccus chrysops 97 R. saxatilis 97 rostrata, Anguilla 57,58 rosyface chub 66,72 rubrifrons, Hybopsis 66,72 sailfin shiner 70,75 salmoides, Micropterus 98,100,111 Salmoniformes 63 sapidissima, Alosa 58,59,61 Savannah darter 116 sawcheek darter 114,119 saxatilis, Morone 96,97 sayanus, Aphredoderus 91 Semionotiformes 55 Semotilus atromaculatus 66,78 serriferum, Etheostoma 114,119 shad American 59,61 gizzard 58,59,62 hickory 59,60 threadfin 58,59,62 shiner bannerfin 70,76 coastal 70,77 dusky 71,74 golden 66,72 ironcolor 70,73 sailfin,70,75 spottail 70,75 taillight 69,77 whitefin 69,77 yellowfin 70,76 sicculus, Labidesthes 95 Siluriformes 83 silver redhorse 79,82 silverside, brook 95

silvery minnow 69,71 snail bullhead 85 sole 121 Soleidae 121 speckled madtom 85,89 speckled worm eel 122 spotfin shiner 122 spottail shiner 70,75 spotted gar 122 spotted sucker 79,82 spotted sunfish 100,110 striped bass 97 striped mullet 120 Strongylura marina 92 sturgeon Atlantic 55 sucetta, Erimyzon 80,81 sucker, spotted 79,82 sunfish 98 banded pygmy 99,105 blackbanded 99,105 bluegill 104,109 bluespotted 99,106 dollar 100,109 flier 99,104 green 100,107 largemouth bass 19,98,100,111 mud 99,104 pumpkinseed 100,107 redbreast 104,106 redear 100,110 spotted 100,110 warmouth 100,108 swamp darter 114,116 swampfish 90,91 taillight shiner 69,77 tadpole madtom 85,88 temperate bass 96 tessellated darter 114,118 threadfin shad 58,59,62 topminnow, lined 93 Trinectes fasciatus 123 maculatus 121, 123 turquoise darter 116,118 Umbra pygmaea 63 Umbridae 63 warmouth 100,108 white bass 96,97 white catfish 83,86 white crappie 99,112 whitefin shiner 69,77 yellow bullhead 85,86 yellowfin shiner 70,76 yellow perch 113,114,1"19 zonatum, Elassoma 99,105 Zygonectes no~ti 93 151

152 APPENDIX I Figures 6, 7A, 8, 13A, 14A, 16C, 22 From Vertebrates of the United States by W. F. Blair, A. P. Blair, P. Brad Korb, F. R. Cagle, and G. A. Moore. © Copyright 1968 McGraw-Hill Book Company. Used by permission of McGraw-Hill Book Company. Figures 7B, 14B From Fishes of the Great Lakes Region by Carl L. Hubbs and Karl L. Lagler. © Copyright 1947, 1958 The University of Michigan. Used by permission of the University of Michigan Press. Figures 6, 13B, 18, 20, 21 From How to Know the Freshwater Fishes by S. Eddy.

  • Used by permission of William C. Brown Company.

Figure 19 From The Fishes of Illinois by Forbes, S. A. and R. E. Richardson. 1920. The fishes of Illinois Second Edition~ Illinois Natural History Survey. Circular 3. Used by permission of Illinois Natural History Survey.

NOTES}}