November 15, 2007 MEMORANDUM TO:
Cliff Munson, Acting Chief Plant Licensing Branch III-1 Division of Operating Reactor Licensing FROM:
Patrick D. Milano, Senior Project Manager /RA/
Plant Licensing Branch III-1 Division of Operating Reactor Licensing
SUBJECT:
FORTHCOMING MEETITNG WITH DOMINION ENERGY KEWAUNEE, INC., CONCERNING THE CURRENT LICENSE AMENDMENT APPLICATION REGARDING INTERNAL FLOODING AT THE KEWAUNEE POWER STATION DATE & TIME:
Thursday, December 6, 2007 9:00 a.m. - 3:30 p.m.
LOCATION:
U.S. Nuclear Regulatory Commission Two White Flint North 11545 Rockville Pike, Room T-2B5 Rockville, MD 20852 PURPOSE:
The purpose of this meeting is to discuss technical issues related to the license amendment request dated March 17, 2006, regarding internal flooding design basis, currently under NRC review for the Kewaunee Power Station.
CATEGORY 1:*
This is a Category 1 Meeting: The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned.
TELECONFERENCE:
Interested members of the public can participate in this meeting via a toll-free teleconference. For details, please call the NRC meeting contact.
CONTACT:
Patrick Milano, NRR Jack Cushing pdm@nrc.gov jxc9@nrc.gov 301-415-1457 301-415-1424
- Commissions Policy Statement on Enhancing Public Participation in NRC Meetings, 67 Federal Register 36920, May 28, 2002
PARTCIPANTS:
Participants from the NRC include members of the Office of Nuclear Reactor Regulation (NRR)
NRC (NRR)
Dominion C. Munson L. Armstrong D. Harrison J. Gausman S. Jones T. Breene J. Fair D. Sommers P. Milano C. Sly M. Kunowski et al.
Docket No. 50-305
Enclosure:
Agenda cc w/encl: See next page
PARTCIPANTS:
Participants from the NRC include members of the Office of Nuclear Reactor Regulation (NRR)
NRC (NRR)
Dominion C. Munson L. Armstrong D. Harrison J. Gausman S. Jones T. Breene J. Fair D. Sommers P. Milano C. Sly M. Kunowski et al.
Docket No. 50-305
Enclosure:
Agenda cc w/encl: See next page DISTRIBUTION:
PUBLIC PMNS Meeting Announcement Coordinator LPL3-1 Reading RidsNrrAdro RidsNrrDorl RidsNrrDorlLpl3-1 RidsNrrDssSbpb RidsNrrDeEmcb RidsNrrPMPMilano RidsNrrLATHarris S. Jones J. Fair T. Liu, NRR RidsRgn3MailCenter D. Jackson, EDO Region III J. Strasma, OPA Region III RidsOgcMailCenter RidsAcrsAcnwMailCenter Receptionist - OWFN and TWFN [paper copy]
RidsOpaMail ADAMS ACCESSION NUMBER: ML073180132 OFFICE RES/DRA/FRB LPL3-1/PM LPL3-1/LA LPL3-1/BC(A)
NAME GTaylor PMilano THarris CMunson DATE 11/15/2007 11/15/2007 11/15/2007 11/15/2007 OFFICIAL AGENCY RECORD
Kewaunee Power Station cc:
Mr. David A. Christian Senior Vice President and Chief Nuclear Officer Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711 Resident Inspectors Office U.S. Nuclear Regulatory Commission N490 Hwy 42 Kewaunee, WI 54216-9510 Regional Administrator, Region III U.S. Nuclear Regulatory Commission Suite 210 2443 Warrenville Road Lisle, IL 60532-4351 Ms. Leslie N. Hartz Dominion Energy Kewaunee, Inc.
Kewaunee Power Station N 490 Highway 42 Kewaunee, WI 54216 Mr. Chris L. Funderburk Director, Nuclear Licensing and Operations Support Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711 Mr. Thomas L. Breene Dominon Energy Kewaunee, Inc.
Kewaunee Power Station N490 Highway 42 Kewaunee, WI 54216 Ms. Lillian M. Cuoco, Esq.
Senior Counsel Dominion Resources Services, Inc.
Millstone Power Station Building 475, 5th Floor Rope Ferry Road Waterford, CT 06385
AGENDA Meeting with Dominion Energy Kewaunee, Inc. (DEK)
Relating to License Amendment Request to Define Internal Flooding Analysis Criteria Kewuanee Power Station Docket No. 50-305 December 6, 2007 Time Topic Presenter 9:00 am Introduction NRC 9:15 am Status of Application March 2006 License Amendment Request to redefine protection from flooding Narrows scope of protection to non-seismic piping Broadens definition of seismically-qualified piping Disregards flood protection for breaks in safety system piping NRC Requests for Additional Information (RAIs) in November 2006 and August 2007 to resolve concerns with scope Response expands position regarding seismically-qualified piping with inadequate basis Dismisses pre-licensing communication regarding flood protection for undefined breaks in safety system piping (e.g., service water and component cooling water)
NRC 10:00 am Flooding Scenarios and Mitigation Extent of consideration of ruptures in non-seismic piping and spray/minor leaks in safety system piping Scope of protected systems (all Class I SSCs or only safe shutdown systems)
End state for flooding initiated events (cold shutdown or hot shutdown)
Mitigation factors (size of leak, operator action, holdup volumes, and drain paths)
DEK 11:30 am Lunch Break
Time Topic Presenter 1:00 pm Classification of potential flooding sources Threshold for consideration as a potential flooding source Need to evaluate non Seismic Class I system Qualification of Class II and III* piping to Operational Basis Earthquake (OBE)
Use of Uniform Building Code Zone 1 criteria as meeting OBE loading Sample analyses to cover full scope of pipe configurations and loading conditions Analysis considers inspection frequency and uncertainties in corrosion effects Class III piping as a flooding source Cast iron piping Safety factor for anchors Factoring in buckling DEK 2:30 pm Comments and Questions NRC 2:45 pm Summary and Project Planning DEK/NRC 3:30 pm Adjourn