D.C. Cook: Draft RAI on Proposed Amendment HEPA Filter Pressure
ML072640058
Person / Time
Site: Cook  
Issue date: 09/18/2007
From: Tam P
NRC/NRR/ADRO/DORL/LPLIII-1
To: Scarpello M, Simpson S
Indiana Michigan Power Co
tam P, NRR/ADRO/DORL, 415-1451
References
TAC MD5931, TAC MD5932
Download: ML072640058 (2)


Text

From:

Peter Tam To:

Scarpello, Michael; Simpson, Sue Date:

09/18/2007 4:00:53 PM

Subject:

D.C. Cook: Draft RAI on proposed amendment re. HEPA filter pressure (TAC MD5931,

2)

Sue:

We are reviewing your applciation for amendment dated June 13, 2007, which proposes to change the Technical Specification surveillance testing acceptance criteria for the Ventilation Filter Testing Program (Technical Specification 5.5.9). Our reviewer Bruce Heida has determined additional information is needed to complete the review, as follows:

You determined that the existing acceptance values are non-conservative. You implemented administrative controls to impose a more restrictive acceptance criterion for the Technical Specification surveillance testing pending the license amendment.

You stated that calculations for the proposed surveillance testing acceptance criteria are based on applicable fan curves and ventilation industry handbook data on system and component resistances. The allowable filter pressure drop is based on [filter] vendor recommendations.

The staff agrees that the existing non-conservative acceptance criterion should be replaced. However, per 10 CFR Part 50.36(c)(3), the staff believes that the acceptance criterion should be based on the total filter assembly pressure drop needed to assure the required minimum air flows. Filter vendor recommendations should be used to determine when to replace individual banks of filters. In order to complete the evaluation of this license amendment, the staff needs the following additional information:

(1) Are the calculated maximum allowable filter assembly pressure drops for the various systems greater than the combined filter vendors= recommended maximum pressure drop values?

(2) How do the handbook resistance values compare with the Aas installed@ and Aas operated@ pressure loss values? Are the Aas installed@ pressure loss values from a testing and balancing (TAB) report?

(3) The licensee indicates that the <four inch water gauge acceptance criterion is based on vendor recommended values for the HEPA/charcoal adsorber assembly. Are pre-filters installed? If pre-filters are installed, why are they not included in the filter assembly total allowable pressure drop?

(4) If testing (TAB or ANSI N509 '8.5.1) has not been performed, how does the licensee assure that the ventilation systems will provide the required minimum air flow at the requested maximum (<four inches water gauge) filter assembly pressure drop?

This e-mail aims solely to prepare you and others for a conference call to discuss these draft questions.

This e-mail does not convey a formal NRC staff position, and does not formally request for additional information. However, with or without the conference call, we plan to issue the questions as a formal RAI in about a month.

Peter S. Tam, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451

CC:

Bruce Heida Mail Envelope Properties (46F02E75.337 : 12 : 35330)

Subject:

D.C. Cook: Draft RAI on proposed amendment re. HEPA filter pressure (TAC MD5931, 2)

Creation Date 09/18/2007 4:00:53 PM From:

Peter Tam Created By:

PST@nrc.gov Recipients Action Date & Time aep.com Transferred 09/18/2007 4:01:07 PM mkscarpello (Michael Scarpello) sdsimpson (Sue Simpson) nrc.gov OWGWPO02.HQGWDO01 Delivered 09/18/2007 4:00:58 PM BRH1 CC (Bruce Heida)

Opened 09/18/2007 4:51:38 PM Post Office Delivered Route aep.com OWGWPO02.HQGWDO01 09/18/2007 4:00:58 PM nrc.gov Files Size Date & Time MESSAGE 4059 09/18/2007 4:00:53 PM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard ReplyRequested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened