October 17, 2007 Dr. David E. Moncton, Director of Nuclear Reactor Lab Nuclear Reactor Laboratory Massachusetts Institute of Technology 138 Albany Street Cambridge, MA 02139

SUBJECT:

INITIAL EXAMINATION REPORT NO. 50-020/OL-07-02, MASSACHUSETTS INSTITUTE OF TECHNOLOGY REACTOR (MITR-II).

Dear Dr. Moncton:

During the week of September 04, 2007, the U.S. Nuclear Regulatory Commission (NRC) administered an initial operator licensing examination at your MITR-II Reactor. The examination was conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed at the conclusion of the examination with those members of your staff identified in the enclosed report.

In accordance with Title 10, Section 2.390, of the Code of Federal Regulations, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). The NRC is forwarding the individual grades to Edward Lau of your staff in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. Paul V. Doyle, Jr. at (301)415-1058 or via internet e-mail pvd@nrc.gov.

Sincerely,

/RA/

Johnny Eads, Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-020

Enclosures:

1. Examination Report No. 50-020/OL-07-02
2. Written Examination cc w/enclosures:

Please see next page

October 17, 2007 Dr. David E. Moncton, Director of Nuclear Reactor Lab Nuclear Reactor Laboratory Massachusetts Institute of Technology 138 Albany Street Cambridge, MA 02139

SUBJECT:

INITIAL EXAMINATION REPORT NO. 50-020/OL-07-02, MASSACHUSETTS INSTITUTE OF TECHNOLOGY REACTOR (MITR-II).

Dear Dr. Moncton:

During the week of September 04, 2007, the U.S. Nuclear Regulatory Commission (NRC) administered an initial operator licensing examination at your MITR-II Reactor. The examination was conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed at the conclusion of the examination with those members of your staff identified in the enclosed report.

In accordance with Title 10, Section 2.390, of the Code of Federal Regulations, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). The NRC is forwarding the individual grades to Edward Lau of your staff in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. Paul V. Doyle, Jr. at (301)415-1058 or via internet e-mail pvd@nrc.gov.

Sincerely,

/RA/

Johnny Eads, Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-020

Enclosures:

1. Examination Report No. 50-020/OL-07-02
2. Written Examination cc w/enclosures:

Please see next page DISTRIBUTION w/ encls.:

PUBLIC PRTB r/f RidsNrrDprPrtb Facility File (CHart) O-12 G-15 RidsNrrDprPrta ADAMS ACCESSION #: ML072630303 Package: ML071500005 TEMPLATE #:NRR-074 OFFICE PRTB:CE IOLB:LA PRTB:SC NAME PDoyle pd CHart cah JEads jhe DATE 10/16/2007 10/17/2007 10/17/2007 OFFICIAL RECORD COPY

Massachusetts Institute of Technology Docket No.50-020 cc:

City Manager City Hall Cambridge, MA 02139 Department of Environmental Protection One Winter Street Boston, MA 02108 Director Radiation Control Program Department of Public Health 90 Washington Street Dorchester, MA 02121 Nuclear Preparedness Manager Massachusetts Emergency Management Agency 40 Worcester Road Framingham, MA 01702-5399 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611 Edward Lau, Reactor Superintendent Nuclear Reactor Laboratory Massachusetts Institute of Technology 138 Albany Street Cambridge, MA 02139

U. S. NUCLEAR REGULATORY COMMISSION OPERATOR LICENSING INITIAL EXAMINATION REPORT REPORT NO.:

50-020/OL-07-02 FACILITY DOCKET NO.:

50-020 FACILITY LICENSE NO.:

R-37 FACILITY:

MITR-II EXAMINATION DATES:

September 04 - 06, 2007 SUBMITTED BY:

____________/RA/____________

__10/16/07___

Paul V. Doyle, Jr., Chief Examiner Date

SUMMARY

During the week of September 03, 2007, the NRC administered operator licensing examinations to 7 operator licensing candidates, five for reactor operator, 1 for senior reactor operator (upgrade) and 1 for senior reactor operator (instant). All seven candidates passed all applicable sections of their operator licensing examinations.

REPORT DETAILS

1.

Examiners:

Paul V. Doyle, Jr., Chief Examiner Phillip T. Young, Examiner

2.

Results:

RO PASS/FAIL SRO PASS/FAIL TOTAL PASS/FAIL Written 5/0 1/0 6/0 Operating Tests 5/0 2/0 7/0 Overall 5/0 2/0 7/0

3.

Exit Meeting:

Paul V. Doyle, Jr., NRC, Examiner Edward Lau, MIT, Reactor Superintendent Frank Warmsley, MIT, Operations Coordinator The examiner thanked the facility staff for their support in the administration of the examination.

The facility staff supplied the examiner with some minor changes to the examination (correction of typographical errors, and two instances where the facility equipment had been modified from the material used to create the examination). The examiners noted an improvement in the level of knowledge demonstrated by this years initial license candidates over previous years initial licensed candidates. The Upgrade candidate, on the other hand, had serious holes in his knowledge which should have been addressed by the facility training program prior to the administration of the NRC examination. We expect the facility training personnel to address these weaknesses with the candidate as soon as possible.

U.S. Nuclear Regulatory Commission Operator Licensing Examination WITH ANSWER KEY

Massachusetts Institute of Technology September 04, 2007

Section A L Theory, Thermo & Facility Operating Characteristics Page 1 QUESTION A.01 [2.0 points, 0.5 each]

Using the drawing of the Integral Rod Worth Curve provided, identify each of the following reactivity worths.

a. Total Rod Worth
1. B - A
b. Actual Shutdown Margin
2. C - A
c. Technical Specification Shutdown Margin Limit
3. C - B
d. Excess Reactivity
4. D - C
5. E - C
6. E - D
7. E - A QUESTION A.02 [1.0 point]

Reactor power is rising on a 100 second period. Approximately how long will it take for power to double?

a. 35 seconds
b. 50 seconds
c. 70 seconds
d. 100 seconds QUESTION A.03 [1.0 point]

During a fuel loading of the core, as the reactor approaches criticality, the value of 1/M:

a. Increases toward one
b. Decreases toward one
c. Increases toward infinity
d. Decreases toward zero QUESTION A.04 [1.0 point]

The number of neutrons passing through a one square centimeter of target material per second is the definition of which one of the following?

a. Neutron Population (np)
b. Neutron Impact Potential (nip)
c. Neutron Flux (nv)
d. Neutron Density (nd)

Section A L Theory, Thermo & Facility Operating Characteristics Page 2 QUESTION A.05 [1.0 point]

Given the following data, which ONE of the following is the closest to the half life of the material?

a. 11 minutes
b. 22 minutes
c. 44 minutes
d. 51 minutes QUESTION A.06 [1.0 point]

Which one of the following describes the characteristics of a good moderator?

a. Low scattering cross section and low absorption cross section
b. Low scattering cross section and high absorption cross section
c. High scattering cross section and low absorption cross section
d. High scattering cross section and high absorption cross section QUESTION A.07 [1.0 point]

The neutron microscopic cross-section for absorption a generally

a. increases as neutron energy increases
b. decreases as neutron energy increases
c. increases as target nucleus mass increases
d. decreases as target nucleus mass increases QUESTION A.08 [1.0 point]

With the reactor on a constant period, which of the following changes in reactor power would take the LONGEST time?

a. 5% from 1% to 6%
b. 15% from 20% to 35%
c. 20% from 40% to 60%
d. 25% from 75% to 100%

TIME ACTIVITY 0

2400 cps 0 min.

1757 cps 0 min.

1286 cps 0 min.

941 cps 60 min 369 cps

Section A L Theory, Thermo & Facility Operating Characteristics Page 3 QUESTION A.09 [1.0 point]

You are assigned to check the operation of a new nuclear instrumentation channel. You know that the reactor will stabilize with a - 80 second period shortly after shutdown. To check the channel you measure the time for power to decrease by a factor of 10. This time should be approximately

a. 45 seconds (3/4 minute)
b. 90 seconds (1-1/2 minutes)
c. 135 seconds (2-1/4 minutes)
d. 180 seconds (3 minutes)

QUESTION A.10 [1.0 point]

Which ONE of the following is the difference between prompt and delayed neutrons? Prompt neutrons

a. account for less than 1% of the neutron population, while delayed neutrons account for the rest.
b. are released during only fast-fission events, while delayed neutrons are released during the decay process.
c. are released during the fission process (fast & thermal), while delayed neutrons are released during the decay process.
d. are the dominating factor in determining reactor period, while delayed neutrons have little effect on reactor period.

QUESTION A.11 [1.0 point]

Shown below is a trace of reactor period as a function of time. Between points A and B reactor power is:

Note this was NOT the original drawing. For this drawing, the question should be between points A and D.

a. continually increasing.
b. continually decreasing.
c. increasing, then decreasing.
d. constant.

QUESTION A.12 [1.0 point]

Which ONE of the following statements correctly describes the concentration of Xenon in the core following a scram from extended operation at 5 Megawatts? Xenon concentration

a. initially decreases due to the loss of Iodine production, then increases to maximum concentration.
b. decreases to a Xenon free condition in approximately 6 to 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />.
c. increases to maximum in approximately 6 to 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> due to the reduction in burnup.
d. remains at equilibrium, because without fission no new Xenon is being produced.

Section A L Theory, Thermo & Facility Operating Characteristics Page 4 QUESTION A.13 [1.0 point]

Which ONE of the reactions below is an example of a PHOTONEUTRON source?

a.

1H2 + 00 v 1H1 + 0n1

b.

92U238 v 35Br87+ 57La148 + 30n1+ 00

c.

51Sb123 + 0n1 v 1H1 + 00

d.

4Be9 + 24 v 6C12 + 0n1 QUESTION A.14 [1.0 point]

ELASTIC SCATTERING is the process by which a neutron collides with a nucleus and

a. recoils with the same kinetic energy it had prior to the collision
b. recoils with less kinetic energy than it had prior to the collision with the nucleus emitting a gamma ray.
c. is absorbed, with the nucleus emitting a gamma ray.
d. recoils with a higher kinetic energy than it had prior to the collision with the nucleus emitting a gamma ray.

QUESTION A.15 [1.0 point]

The term Prompt Critical refers to:

a. the instantaneous jump in power due to a rod withdrawal
b. a reactor which is supercritical using only prompt neutrons
c. a reactor which is critical using both prompt and delayed neutrons
d. a reactivity insertion which is less than eff QUESTION A.16 [1.0 point]

Which one of the following factors is the most significant in determining the differential worth of a control rod?

a. The rod speed.
b. Reactor power.
c. The flux shape.
d. The amount of fuel in the core.

Section A L Theory, Thermo & Facility Operating Characteristics Page 5 QUESTION A.17 [1.0 point]

Which one of the following conditions would INCREASE the shutdown margin of a reactor?

a. Inserting an experiment adding positive reactivity.
b. Lowering moderator temperature if the moderator temperature coefficient is negative.
c. Depletion of a burnable poison.
d. Depletion of uranium fuel.

QUESTION A.18 [1.0 point]

Which one of the following is the principal source of heat in the reactor after a shutdown from extended operation at 5.0 MW?

a. Production of delayed neutrons
b. Subcritical reaction of photo-neutrons
c. Spontaneous fission of U238
d. Decay of fission fragments QUESTION A.19 [1.0 point]

Which one of the following statements describes why installed neutron sources are used in reactor cores?

a. To increase the count rate by an amount equal to the source contribution.
b. To increase the count rate by 1/M (M = Subcritical Multiplication Factor).
c. To provide neutrons to initiate the chain reaction.
d. To provide a neutron level high enough to be monitored by instrumentation.

Section B Normal, Abnormal, Emergency & Radiological Control Procedures and Tech Specs Page 6 QUESTION B.01 [1.0 point]

Which ONE of the following situations would illustrate a time when the reactor is shutdown but NOT secured?

a. One of the control rods is removed for inspection while the other control rods are fully inserted and all fuel remains in the same configuration.
b. All control rods are fully inserted and fuel is being rearranged in the fuel storage pool.
c. The control rods are withdrawn to the subcritical position and the core is subcritical by 1% K/K.
d. All control rods are fully inserted and an experiment having a negative reactivity effect is installed in the reactor.

QUESTION B.02 [1.0 point]

What action should be taken if the shim bank exceeds the estimated critical position (ECP) by more than 0.5 inches and the reactor has not reached criticality?

a. Continue withdrawing rods until the reactor is critical and note new rod heights in log book.
b. Immediately scram the reactor and follow the appropriate emergency procedure.
c. Notify the SRO on duty and continue under careful scrutiny.
d. Lower rods by 1 inch or more and determine the cause of the discrepancy.

QUESTION B.03 [2.0 points, 1/4 each]

Identify whether each of the following plans and procedures are designated as Class A, Class B or Class C.

a. Administrative Procedure PM 1.10 Experiment Review and Approval
b. Abnormal Operating Procedure PM 5.3.3 Low Level D2O Reflector
c. Administrative Procedure PM 1.16 Requalification Plan for Licensed Personnel
d. Standard Operating Plan PM 2.1 General Instructions QUESTION B.04 [1.0 point]

What is the lowest level of supervision that can waive the daily surveillance check?

a. Operations coordinator.
b. Superintendent.
c. Shift supervisor.
d. Operator.

Section B Normal, Abnormal, Emergency & Radiological Control Procedures and Tech Specs Page 7 QUESTION B.05 [1.0 point]

In response to a "COOLING TOWER FANS OFF" alarm an attempt to restart the fans was unsuccessful. With the reactor operating at 4 MW the immediate action required is to:

a. perform a minor scram.
b. perform a major scram.
c. shut the secondary blowdown valves and monitor primary coolant flow.
d. depress the "ALL RODS IN" pushbutton and lower power to 1 MW or less.

QUESTION B.06 [2.0 points, 1/2 each]

Match type of radiation (a thru d) with the proper penetrating power (1 thru 4)

a. Gamma
1. Stopped by thin sheet of paper
b. Beta
2. Stopped by thin sheet of metal
c. Alpha
3. Best shielded by light material
d. Neutron
4. Best shielded by dense material QUESTION B.07 [1.0 point]

Based on the Requalification Plan for licensed personnel, each licensed operator must complete a minimum of

______ reactivity manipulations during each 2 year cycle.

a. 4
b. 10
c. 20
d. 28 QUESTION B.08 [1.0 point]

With the reactor top shield NOT in place, the maximum allowed power level is

a. 100 W
b. 1.0 kW
c. 10.0 kW
d. 100.0 kW

Section B Normal, Abnormal, Emergency & Radiological Control Procedures and Tech Specs Page 8 QUESTION B.09 [1.0 point]

Two senior reactor operators are operating the reactor at night. One receives a phone call for an emergency at home. They drive all the control rods in and shutdown the reactor. The minimum complement of personnel required to restart the reactor is to call in a 2nd person who is a

a. student.
b. operator-in-training.
c. licensed operator
d. licensed senior operator QUESTION B.10 [1.0 point]

A four inch thick steel plate reduces the gamma radiation dose rate from 60 mrem/hr to 6 mrem/hr. If a one inch plate of the same composition steel is added, the new dose rate will be

a. 0.56 mrem/hr.
b. 1.50 mrem/hr.
c. 2.62 mrem/hr.
d. 3.37 mrem/hr.

QUESTION B.11 [1.0 point]

According to the Emergency Plan, the Emergency Planning Zone (EPZ) is

a. the area within the containment building including the airlocks.
b. the area included within the containment building, buildings NW-12 and NW-13 and the chain link fence surrounding the areas outside.
c. the area within a 100 foot radius of the containment building.
d. the area within a 100 meter radius of the containment building.

QUESTION B.12 [1.0 point]

Administrative Procedure 1.10.8 requires the use of tongs at least 6 inches long to handle irradiated rabbit samples.

The reason for this control is the presence of probable high

a. alpha radiation levels
b. beta radiation levels
c. gamma radiation levels
d. surface temperature of the polyethylene container

Section B Normal, Abnormal, Emergency & Radiological Control Procedures and Tech Specs Page 9 QUESTION B.13 [2.0 points, 1/2 each]

Identify each of the four surveillances listed as a channel CHECK, a channel TEST, or a channel CALibration.

a. During shutdown you verify operation of period channel by verifying power decreases by a factor of 10 in three minutes
b. Following maintenance on Nuclear Instrument channel 1 you compare its readings to Nuclear Instrument channel 2 readings.
c. You verify a temperature channel's operation by replacing the RTD with a precision variable resistance and checking proper output.
d. You a heat balance (calorimetric) on the primary system and based on Nuclear Instrumentation readings you make adjustments.

QUESTION B.14 [1.0 point]

Which one of the following materials requires monitoring of container during irradiation?

a. Metastable
b. Explosive
c. Corrosive
d. Radiolytically Decomposable QUESTION B.15 [1.0 point]

Technical Specification defines a reportable occurrence as 1. any actual safety system setting less conservative than specified in these Technical Specifications. Using this guidance, which one of the following is a reportable occurrence, if discovered during normal operations?

a. Nuclear Instrumentation Channel 4 High Flux scram setpoint is 5.7 MW
b. Main Tank Low coolant level scram setpoint is 4 inches below overflow pipe
c. Reactor Coolant Outlet temperature scram setpoint is 65C
d. Primary coolant flow rate scram setpoint is 1750 gpm.

QUESTION B.16 [1.0 point]

During a frisk you discover one of your hands is contaminated. Which one of the following would be your initial attempt to remove the contamination?

a. Use of a mildly acidic solvent, rinsed with hot water.
b. Wash hand with soap and lukewarm water.
c. Wash hand with grit, and cold water.
d. Wipe hand with dry paper towels.

Section B Normal, Abnormal, Emergency & Radiological Control Procedures and Tech Specs Page 10 QUESTION B.17 [1.0 point]

N16 has a very short half-life. If you assume that it takes 10 HALF-LIVES worth of time for the water to get from the core to the sample connection, then the activity due to N16 will have decrease by a factor of approximately ___ with respect to the level at the exit of the core.

a. 20
b. 100
c. 200
d. 1000

Section C Plant and Rad Monitoring Systems Page 11 QUESTION C.01 [2.0 points, 1/4 each]

Choice e changed to reflect facility modifications.

For purposes of this examination choice e was deleted.

Please identify each of the channel descriptions with the applicable oddly numbered channel (1, 3, 5, 7 or 9).

a. Uses COMPENSATED ion chamber with NO compensating voltage applied.
b. Uses two detectors an ion chamber and a fission chamber to detect neutrons.
c. Powered by a replaceable cell battery pack.
d. Uses a COMPENSATED ion chamber to detect neutron signal proportional to power level.
e. Uses an ion chamber fission chamber to detect GAMMA neutron signal proportional to power level.
f.

Supplies power signal to the automatic control circuit.

g. Supplies High Flux scram at level corresponding to 5.5 MW.
h. Uses an UNCOMPENSATED ion chamber to detect neutron signal proportional to power level QUESTION C.02 [1.0 point]

To prevent a catastrophic loss of pressure, all Differential Pressure system containment penetrations

a. contain a 1/32 inch diameter orifice
b. have a quick shutting solenoid valve
c. are submerged in a water seal trap
d. have check valves preventing air from leaking into the containment.

QUESTION C.03 [1.0 point]

What is the purpose of the long hold up chamber, or plenum, in the exhaust air system?

a. To allow for the thorough measurement of the radiation levels in the exhaust air.
b. To enable the shorter lived activation products to decay before they are exhausted.
c. To filter out the particulates that would result in an airborne radiation release to the environment.
d. To delay the exhaust long enough for the butterfly dampers to close if the plenum monitor alarms.

QUESTION C.04 [1.0 point]

What is indicated when an alarm on the annunciator alarm (SCAM) panel is silent, but is continuously brightly lit?

a. The alarm condition has been corrected but not acknowledged.
b. The alarm condition has been acknowledged but not corrected.
c. The alarm condition has neither been acknowledged nor corrected.
d. The alarm condition has been acknowledged and corrected and only serves as a reminder to the operator.

Section C Plant and Rad Monitoring Systems Page 12 QUESTION C.05 [1.0 point]

What is one of the purposes for the subcritical interlock?

a. To prevent the reactor from being manipulated to a critical position before the startup channels are switched from fission chambers to uncompensated ion chambers.
b. To provide a reference point where all instruments undergo a check before the reactor is brought to a critical position.
c. To allow for all experiments to be installed before the reactor is critical.
d. To ensure that a steady rate of startup to the critical position is achieved.

QUESTION C.06 [1.0 point]

The neutron absorbing sections of the shim control rods contain boron impregnated

a. graphite
b. aluminum
c. cadmium
d. stainless steel QUESTION C.07 [1.0 point]

Which one of the following flow detectors does NOT use a flow orifice?

a. Primary Flow, MF-1.
b. Reflector Flow, DF-1.
c. Shield Flow, PF-1.
d. Secondary Flow, HF-1A.

QUESTION C.08 [1.0 point]

Which one of the following conditions is NOT a cause of the trouble radiation monitor alarm occurring?

a. Loss of flow to any plenum monitor
b. Saturation of secondary water monitor
c. Low level on any effluent monitor
d. Loss of flow to any stack effluent monitor

Section C Plant and Rad Monitoring Systems Page 13 Choice c deleted per facility comment. Thermal column converted to fission converter for the new BNCT facility.

QUESTION C.09 [1.0 point]

Which one of the following list the two radio-nuclides which will be seen by the detectors in the secondary water system signaling that there is a leak within one of the heat exchangers with the reactor operating normally (no fuel element failure)?

a. Xe135 and Ar41
b. H3 and F18
c. Ar41 and N16
d. F18 and N16 QUESTION C.10 [1.0 point]

What is the purpose of the coolant system for the lead thermal shields?

a. To maintain thermal equilibrium between the lead shields and the adjacent graphite reflector.
b. To maintain the thermal neutron shielding properties of the lead.
c. To prevent melting of the lead.
d. To prevent activation of lead by fast neutrons.

QUESTION C.11 [2.0 points, 1/2 each]

Match the reactor location or feature from Column I with the gas from Column II which is used as the primary cover or operating gas. Items in Column I have only one correct answer and items in Column II may be used once, more than once or not at all.

Column I Column II

a. Graphite Reflector
1. CO2
b. Lead shutter region gas box
2. Ar40
c. Thermal Column
3. He
d. Cover gas for D2O reflector tank
4. N2 QUESTION C.12 [1.0 point]

During an accident the Containment Building approaches its design pressure. Which one of the following is the design feature which provides over-pressure protection for the containment?

a. A pressure relief blower automatically initiates at 2.0 psig.
b. A containment relief valve will automatically open at 1.75 psig.
c. A manually operated relief valve may be opened to protect containment.
d. The main damper will cycle open and closed to maintain containment pressure less than 1.75 psig.

Section C Plant and Rad Monitoring Systems Page 14 QUESTION C.13 [1.0 point]

If the normal heat removal path is NOT available for the Shutdown Cooling System, alternative cooling can be obtained from the:

a. fire protection system.
b. secondary cooling system.
c. city water supply to HE-2.
d. H2O medical shutter cooling system.

QUESTION C.14 [1.0 point]

In addition to Nuclear Instrumentation channels 1 through 9, reactor power may also be estimated using which ONE of the listed radiation monitors?

a. Argon-41
b. Reactor Top
c. Medical Room
d. Linear N-16 QUESTION C.15 [1.0 point]

Which ONE of the following statements correctly describes the "automatic rundown" interlock? With reactor control on

a. automatic, if the regulating rod reaches the near-in limit the selected shim blade will run in after 30 seconds.
b. manual, if the regulating rod reaches the near-in limit the selected shim blade will run in after 30 seconds.
c. automatic, if the regulating rod reaches the near-in limit all shim blades will run in after 30 seconds.
d. automatic, if the regulating rod reaches the near-out limit, the selected shim blade will run in after 30 seconds QUESTION C.16 [1.0 point]

Which ONE of the following is NOT a function associated with the reactor upper grid?

a. Trip primary pump if grid is unlatched.
b. Limit refueling to one element position at a time.
c. Ensure blades are fully inserted before a refueling is initiated.
d. Provide a position for source installation if counts are below minimum for a startup.

Section C Plant and Rad Monitoring Systems Page 15 QUESTION C.17 [1.0 point]

How are the stack accumulators verified to be operable?

a.

A signal is introduced into the detector and if the detector records readings, then it is operable.

b.

The background signal is observed and compared to previously know background levels.

c.

A check source is placed next to the detector and the value is compare to previous values.

d.

The system is checked for the illumination of an error light.

QUESTION C.18 [1.0 point]

Note: 10 changed to 3 for future questions, no change to grading.

Which ONE of the following describes an automatic response of the ventilation system?

a. If temperature of the outside air drops below approximately 35F the intake fan will trip.
b. If the main intake damper fails to close within 10 3 seconds of a trip signal, then the intake fan will trip.
c. If the auxiliary intake damper fails to close within 10 3 seconds of a trip signal, then the main damper will close.
d. In the "weekend-open" position, if activity is detected by the plenum monitors, the inlet dampers and intake fan will trip.

Section B Normal, Abnormal, Emergency & Radiological Control Procedures and Tech Specs Page 16 A.01 a, 7; b, 2; c, 1; d, 5 REF:

Standard NRC Question A.02 c

REF:

P = P0 et/T --> ln(2) = time ÷ 100 seconds -> time = ln(2) x 100 sec. 0.693 x 100 0.7 x 100 70 sec.

A.03 d

REF:

A.04 c

REF:

A.05 b (22 minutes)

REF:

A.06 c

REF:

A.07 b

REF:

A.08

a.

REF:

P = P0 et/ ln(P/P0) = t/ You are looking for which would take the longest time therefore the ratio P/P0 must be the largest.

A.09 d

REF:

P/P0 = e-T/ ln(0.1) = - T(time)/(-80sec) Time = ln (0.1) x -80 sec = 184 seconds 3 minutes A.10 c

REF:

Burn, R., Introduction to Nuclear Reactor Operations, © 1988, § A.11 a

REF:

Standard NRC Question1 A.12 c

REF:

Burn, R., Introduction to Nuclear Reactor Operations, © 1988, § xxxx A.13 a

REF:

Burn, R., Introduction to Nuclear Reactor Operations, © 1988, § 3.3.1, P. 3-16.

A.14 a or b. 2nd correct answer added per facility comment.

REF:

DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory, Volume A.15 b

Ref:

DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory Volume 2, Module 4, Enabling Objective 2.8, p. 15.

A.16 c

Ref:

DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory Volume 2, Module 3, Enabling Objective 5.4, p. 51.

A.17 d

Ref:

DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory Volume 2, Module 4, Enabling Objective 3.6 p. 28.

Section B Normal, Abnormal, Emergency & Radiological Control Procedures and Tech Specs Page 17 A.18 d

Ref:

DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory Volume 1, Module 1, Enabling Objective 4.9, p. 61.

A.19 d

Ref:

DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory Volume 1, Module 1, Enabling Objective

Section B Normal, Abnormal, Emergency & Radiological Control Procedures and Tech Specs Page 18 B.01 d

REF:

Technical Specifications 1.1 and 1.2. Also previous NRC examination B.02 d

REF:

PM 2.3 Page 2 of 7; PM 3.1.7 B.03 a, B; b, B; c, A; d, A REF:

AP1.4 Review and Approval of Plans, Procedures, and Facility Equipment and Changes Thereto. Page 1 of 1.

B.04 b

REF:

PM 2.2 Pg. 9 of 11 B.05 d Question deleted (no correct answer due to facility modifications).

REF:

PM 5.4.12 B.06 a, 4; b, 2; c, 1; d, 3 REF:

Standard NRC Health Physics Question B.07 b

REF:

AP 1.16 Requalification Plan for Licensed Personnel, § 1.16.1.2a, On-the-Job Training B.08 d

REF:

TS 3.11.2.d B.09 c

REF:

AP 1.14 General Safety Rules § 1.14.1(3)

B.10 d

REF:

374

.3 60 5756

.0 4

)1.0 ln(

)

4

(

)

ln(

)

5

(

5756

.0 60 6

0

=

=

=

=

=

=

inches f

x f

e A

inches e

A A

B.11 d

REF:

B.12 b

REF:

AP 1.10.8.1.1(11)

B.13 a, CHECK or TEST; B, CHECK; C, TEST; D, CAL 2nd correct answer for part a added due to examiner review.

REF:

MITR-II Tech Spec. §§ 1.12, 1.13 & 1.14 B.14 c

REF:

MITR-II Tech. Spec. § 6.1, Table 6.1-1.

B.15 c or d. 2nd correct answer added per facility comment.

REF:

MITR-II Tech. Spec. §§ 1.5 & 2.2 (Rewritten)

B.16 b

REF:

PM 4.4.4 B.17 d

REF:

210 = 1024 1000

Section C Plant and Rad Monitoring Systems Page 19 C.01 a, 3; b, 1; c, 3; d, 7; e, 9; f, 9; g, 5; h, 5 Ref:

Reactor Systems Manual, Chapter 5.

Choice e deleted (no correct answer due to facility modifications).

C.02 a

REF:

MITR-II Reactor Systems Manual § 6.7, p. 6-12 C.03 d

REF: RSM 8-14 C.04 b

REF: RSM 9-2 C.05 b

REF:

MITR-II, Reactor System Manual § 4.3 C.06 d

REF:

MITR-II Reactor Systems Manual, § 1.10 C.07 a

REF:

MITR-II Training Program Sample Question C.24, also Reactor Systems Manual §§ 6.4.1 & 6.4.2.

C.08 b

REF:

Reactor Systems Manual §§ 7.12 & 7.15 (Table 7.5-1)

C.09 d

REF:

Reactor Systems Manual § 7.8 C.10 c

REF:

Reactor Systems Manual § 3.16 C.11 a, 1; b, 1; c, 1; d, 3 Choice c deleted, Thermal Column was converted to a Fission Converter for the new BNCT medical facility.

REF:

Reactor Systems Manual § 3.7 C.12 c

REF:

Reactor Systems Manual § 8.23 C.13 c

REF:

Reactor Systems Manual § 3.2.6; PM 5.2.8, Step B.2 C.14 d

REF:

Reactor Systems Manual § 5.1 C.15 a

REF:

Reactor Systems Manual § 4.5 C.16 d

REF:

Reactor Systems Manual § 1.4 C.17 a

REF:

PM 3.1.2.2 Pg. 1 of 14 C.18 a

REF:

RSM-8.3.1