Renewal Hearing - Meeting (Conference Call) Summary
ML072530028
Person / Time
Site: Pilgrim
Issue date: 08/24/2007
From:
Office of Nuclear Reactor Regulation
To:
References
06-848-02-LR
Download: ML072530028 (6)


Text

From:

Perry Buckberg To:

"Bryan Ford" <bford@entergy.com>

Date:

8/24/2007 9:58:24 AM

Subject:

Meeting (Conference Call) Summary cc:

"Edward Sanchez" <esanch1@entergy.com>

Bryan, Please reply with your concurrence regarding the attached record of yesterday's phone conference.
Thanks, Perry Buckberg Project Manager - Division of License Renewal phone: (301)415-1383 fax: (301)415-3031 phb1@nrc.gov

Hearing Identifier:

PilgrimRenewalNonPublic Email Number:

24 Mail Envelope Properties (46E50485.HQGWDO01.TWGWPO03.200.2000009.1.1270E9.1)

Subject:

Meeting (Conference Call) Summary Creation Date:

8/24/2007 9:58:24 AM From:

Perry Buckberg Created By:

PHB1@nrc.gov Recipients "Edward Sanchez" <esanch1@entergy.com>

"Bryan Ford" <bford@entergy.com>

Post Office Route TWGWPO03.HQGWDO01 nrc.gov Files Size Date & Time MESSAGE 252 8/24/2007 9:58:24 AM TEXT.htm 647 9/10/2007 8:47:01 AM MeetingSummary August 23, 2007 (PNPS).wpd 15550 9/10/2007 8:47:01 AM Options Priority:

Standard Reply Requested:

No Return Notification:

None None Concealed

Subject:

No Security:

Standard

Bryan, Please reply with your concurrence regarding the attached record of yesterday's phone conference.
Thanks, Perry Buckberg Project Manager - Division of License Renewal phone: (301)415-1383 fax: (301)415-3031 phb1@nrc.gov Page 1 of 1 9/10/2007 file://c:\\EMailCapture\\PilgrimRenewalNonPublic\\24\\attch1.htm

LICENSEE:

Entergy Nuclear Operations, Inc.

FACILITY:

Pilgrim Nuclear Power Station

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON AUGUST 23, 2007, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC., CONCERNING REQUESTS FOR ADDITIONAL INFORMATION PERTAINING TO THE PILGRIM NUCLEAR POWER STATION, LICENSE RENEWAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Entergy Nuclear Operations, Inc. held a telephone conference call on August 23, 2007, to discuss and clarify the staffs requests for additional information (RAIs) concerning the Pilgrim Nuclear Power Station, license renewal application. The telephone conference call was useful in clarifying the intent of the staffs RAIs. provides a listing of the participants and Enclosure 2 contains a listing of the RAIs discussed with the applicant, including a brief description on the status of the items.

The applicant had an opportunity to comment on this summary.

Perry Buckberg, Project Manager License Renewal Branch A Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-293

Enclosures:

1. List of Participants
2. List of Requests for Additional Information cc w/encls: See next page TELEPHONE CONFERENCE CALL PILGRIM NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS AUGUST 23, 2007 PARTICIPANTS AFFILIATIONS Pao Tsin Kuo U.S. Nuclear Regulatory Commission (NRC)

Ken Chang NRC Louise Lund NRC Perry Buckberg NRC Peter Wen NRC James Medoff NRC Gary Young Entergy Nuclear Operations, Inc. (Entergy)

Steve Bethay Entergy Bryan Ford Entergy Fred Mogolesko Entergy Alan Cox Entergy Rick Plasse Entergy David Mannai Entergy REQUESTS FOR ADDITIONAL INFORMATION

PILGRIM NUCLEAR POWER STATION LICENSE RENEWAL APPLICATION AUGUST 23, 2007 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of Entergy Nuclear Operations, Inc. held a telephone conference call on August 23, 2007, to discuss and clarify the following requests for additional information (RAIs) concerning the Pilgrim Nuclear Power Station (PNPS), license renewal application (LRA).

RAI # 4.3.3-1 Discussion: Based on the discussion with the applicant, the staff indicated that the response to this RAI requires clarification. Therefore, the applicant will clarify the information.