ML072290561

From kanterella
Jump to navigation Jump to search
Discharge Monitoring Report for July 2007
ML072290561
Person / Time
Site: Sequoyah  
Issue date: 08/14/2007
From: Howard S
Tennessee Valley Authority
To:
Office of Nuclear Reactor Regulation, State of TN, Dept of Environment & Conservation, Div of Water Pollution Control
References
Download: ML072290561 (13)


Text

Tennessee Valley Authority, Post Office Box 2000, Soddy-Daisy, Tennessee 37379-2000 August 14, 2007 State of Tennessee Department of Environment and Conservation Division of Water Pollution Control Enforcement & Compliance Section 6"' Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534

Dear Mr. Hannah:

SEQUOYAH NUCLEAR PLANT - DISCHARGE MONITORING REPORT FOR JULY 2007 Enclosed is the July 2007 Discharge Monitoring Report for Sequoyah Nuclear Plant. Please contact me at (423) 843-6700 if You have any questions or comments.

Sincerely, Stephanie A. Howard Principal Environmental Engineer Signatory Authority for J. Randy Douet Site Vice President Sequoyah Nuclear Plant Enclosure cc (Enclosure):

Chattanooga Environmental Assistance Center Division of Water Pollution Control State Office Building, Suite 550 540 McCallie Avenue Chattanooga, Tennessee 37402-2013 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Pr~,rtJ on pecpIed

PERMI-TEE NAME/ADDRESS (Include Facil/tt Name/Location ilDifferent)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE SB-2A.)

SODDY - DAISY TN 37384 Facili.y TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

TN0026450 101 G F-FINAL PERMIT NUMBER I DISCHARGE NUMBER DIFFUSER DISCHARGE MONITORING PERIOD EFFLUENT Form Approved.

OMB No. 2040-0004 YEAR MO iDAY YEAR M

DAY FromI 07 07 To[ 07 07 31 NO DISCHARGE NOTE: Read instructions before completinl this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE

.U EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITSANALYSIS TEMPERATURE, WATER DEG.

SAMPLE 1

30.2 04 31 I 31 MODELD CENTIGRADE MEASUREMENT T

00010 Z

0 0

PERMIT 30.5 DEG. C.

SEE CK REQ INSTREAM MONITORING REQUIREMENT..

DAILYMX PERMIT TEMPERATURE, WATER DEG.

SAMPLE 42.1 04 0

31 / 31 RCORDR CENTIGRADE MEASUREMENT 00010 1

0 0

PERMIT REPORT DEG. C.

.:..SEE

'.CK REQ EFFLUENT GROSS VALUE REQUIREMENT

.. ° DAILY MX PERMIT,.

TEMP. DIFF. BETWEEN SAMP. &

SAMPLE 2.7 04 0

31 / 31 CALCTD UPSTRM DEG.C MEASUREMENT 00016 1

S 0

PERMIT 3 0 DEG. C.

CONTIN

CALCTD EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS PH SAMPLE 7.3 7.6 12 0

6/31 GRAB MEASUREMENT 00400 1

0 0

PERMIT

  • 6.0 9.0 SU WEEKLY GRAB EFFLUENT GROSS VALUE REQUIREMENT M

,,MINIMUM" MAXIMUM SOLIDS, TOTAL SUSPENDED SAMPLE 4

4 19 0

1 / 31 GRAB MEASUREMENT 00530 1

0 0

PERMIT.

30 100 MGIL MONTHLY:. GRAB:,

EFFLUENT GROSS VALUE.

REQUIREMENT.I

.MO AV DAIL X

  • ...t..

=

MO'AVG ".DAILY.

MX" OIL AND GREASE SAMPLE

<6

<6 19 0

1 / 31 GRAB MEASUREMENT 00556 1

0 0

.. PERMIT..

15 A.

20.

MG/L MONTHLY GRAB EFFLUENT GROSS VALUE REQUIREMENT MO AVG DAILY MX FLOW, IN CONDUIT OR THRU SAMPLE 1629 03 0

31/31 FRCOROR' TREATMENT PLANT MEASUREMENT 50050 1

0 0

PERMITR MGD

-CONTIN RCORDR EFFLUENT GROSS VALUE REQUIREMENT DAILY MX UOUS NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer Site Vice President information, the information submitted is, to the best of my knowledge and belief, true, 423 843-6700 07 08 14 accurate. and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE information, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No closed mode operation. The following information is included in an attachment:. CCW data, EPA Form 3320-1 (REV 3/99)

Previous editions may be used Page 1 of 2

July 2007 DMR Attachment July 2007 CCW Data CCW TRENCH Extractable Petroleum Date/Time Collected Hydrocarbons Analysis Date/Time Analyst Method 07/12/2007 @ 1035 0.44 mg/L 07/17/2007 @ 0915 TSF EPA 8015 CCW CHANNEL Extractable Petroleum Date/Time Collected Hydrocarbons Analysis Date/Time Analyst Method 07/12/2007 @ 1030

<0.10 mg/L 07/17/2007 @ 0926 TSF EPA 8015

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE SB-2A

)

SODDY - DAISY TN 37384 Facility-TVA - SEQUOYAH NUCLEAR PLANT Locati.on HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

TN0026450 I

101G F-FINAL L

PERMIT NUMBER DISCHARGE NUMBE7R DIFFUSER DISCHARGE Form Approved.

OMB No. 2040-0004 MONITORING PERIOD

  • YE YEAR MO I DAY From o7L1ool j To 07 07I 31 EFFLUENT NO DISCHARGE NOTE: Read instructions before completjnq this form ATTN: Stephanie A. Howard PARAMETER CHLORINE, TOTAL RESIDUAL 50060 1

0 0

EFFLUENT GROSS VALUE TEMPERATURE - C, RATE OF CHANGE 82234 1

0 0

EFFLUENT GROSS VALUE

>1 QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

EX FREQUENCY SAMPLE OF TYPE ANALYSIS AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS SAMPLE MEASUREMENT 0.022 0.037 19 MGIL 0

26/31

  • WEEK-.

DAYS.

GRAB CALCTD PERMITý REQUIREMENT 0.10 0.10

MO AVG.

INST MAX SAMPLE MEASUREMENT 0

--I I-PERMIT REQUIREMENT 62 DEG CIHR 0

31/31 CALCTD

.CALCTD 2

DAILY MX CONTIN UOUS SAMPLE MEASUREMENT PERMITQUIRE REQUIREMENT SAMPLE MEASUREMENT PERMIT.

.REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT T

t 1

4 4

I F

I 4

SAMPLE MEASUREMENT

-I-4 PERMIT:

REQUIREMENT SAMPLE

-MEASUREMENT

  • PERMIT***

REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, Site Vice President accurate, and complete. I am aware that there are significant penalties for submitting false TYPED__ OR__PRINTEDinformalion, including the possibility of fine and imprisonment for knowing violations.

TYPED OR PRINTED TELEPHONE DATE Principal Environmental Engineer 423 843-6700 SIGNATURE OF PRINCIPAL EXECUTIVE AREA

_NUMBER OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

The following injections occured: 1.Biodetergent 73551 (max. calc. conc. was 0.018mg/L--limit 2.0mg/L) 2.MSW-101 (max. calc. conc. was 0.091mg/L--limit 0.2mg/L) 3.H-150M (max. calc. conc. was 0.036mg/L--limit 0.050mg/L) 4.H-150M (low detection level analytical method was <0.020mg/L--limit 0.050mg/L)

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 2 of 2

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE SB-2A)

SODDY - DAISY TN 37384 Facility TVA-SEOUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR For DISCHARGE MONITORING REPORT (DMR)

(SUBR 0Oiol TN0026450

]l T

F-FINAL PERMIT NUMBER DISCHARGE NUMBER BIOMONITORING FOR OUTFALL 101 MON T NG PERIOD R

EFFLUENT m Approved.

lB No. 2040-0004 ATTN: Stephanie A. Howard PARAMETER lIC25 STATRE 7DAY CHR CERIODAPHNIA TRP3B 1

0 0

EFFLUENT GROSS VALUE IC25 STATRE 7DAY CHR PIMEPHALES TRP6C 1

0 0

EFFLUENT GROSS VALUE I YEAR I MO 01I T°IYEAR 0

O DYI NO DISCHARGE E

NOTE: Read instructions before compteting this form.

QUANTITY OR LOADING 1

QUALITY OR CONCENTRATION NO.

iFREQUENCY SAMPLE SEX OF TYPE ANALYSIS AVERAGE MAXIMUM UN ITS MINIMUM AVERAGE MAXIMUM U NITS SAMPLE Monitoring 23 MEASUREMENT Not Required 23 PERMIT

                • ..45.2 PERCENT SEE COMPOS REQUIREMENT M IN IM U M :::

PERM IT SAMPLE MEASUREMENT Monitoring Not Reauired 23 PERCENT i

i PERMIT REQUIREMENT

".45.2 MIMINUM SEE PERMIT COMPOS SAMPLE MEASUREMENT

-i

+

PERMIT.

REQUIREMENT SAMPLE MEASUREMENT

  • PERMIT.

.REQUIREMENT.

SAMPLE MEASUREMENT PERMIT :._"__.....:._._.._._._"

REQ.UIREMENT --.....

SAMPLE MEASUREMENT PERMIT.

REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER J. Randy Douet Site Vice President I Certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief. true, accurate, and complete. I am aware that there are significant penalties for submitting false nformalion, including the possibility of fine and imprisonment for knowing violations.

Principal Environmental Engineer SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT

___A TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

Toxicity was not sampled in July 2007.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE SB-2.A)

SODDY - DAISY TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (DMR)

TN0026450 1 -

101 Y PERMIT NUMBER

] [DISCHARGE NUMBER MONITORING PERIOD YEART MO DAY YEAR MO DAY From 06108 01 To0 7

1 MAJOR Form Approved.

(SUBR 01)

OMB No. 2040-0(

F - FINAL ANNUAL MONITORING (PCBS)

EFFLUENT NO DISCHARGE D NOTE: Read inslructions before completing this form.

004 ATTN: Stephanie A. Howard SAMPLE TYPE PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY EX OF ANALYSIS SAMPLE TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS POLYCHLORINATED. BIPHENYLS 39521 1

0 0

EFFLUENT GROSS VALUE

-~

4 5

I I-I 4

-i SAMPLE MEASUREMENT

<0.0 0

19 MG/L 1 / 365 ANNUAL GRAB "GRAB PERMIT*

REQUIREMENT 0.0 SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT i

i PERMIT.

REQUIREMENT SAMPLE MEASUREMENT

. PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT

.REQUIlREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER dI Certify under penalty of law that this document and all attachments were prepared under my 5

h'_

TELEPHONE I

DATE direction or supervision in accordance with a system designed to assure that qualified personnel o

J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or

)2-"1D' persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer 423 843-6700 7

08 Sinformation. the information submitted is, to ihe best of my knowledge and belief, true, Site Vice President accurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE 0

information, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER Y

MOE TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

PCB samples were taken on 07/05/2007 @ 1035.

EPA Form 3320-1 (REV 3/99)

Previous editions may be used Page I of 1

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFE SB-2A.

SODDY - DAISY TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR Form DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

OMB TN0026450 103 G F - FINAL PERMIT NUMBER SCHARGE NUERJ LOW VOL. WASTE TREATMENT POND MONITRING.PERIOD EFFLUENT Approved.

No. 2040-0004 From 07j07J~jT NO DISCHARGE Z NOTE: Read instructions before completing this form.

PARAMETER PH 00400 1

0 0

EFFLUENT GROSS VALI SOLIDS, TOTAL SUSPE 00530 1

0 0

EFFLUENT GROSS VALL OIL AND GREASE 00556 1

0 0

EFFLUENT GROSS VALI FLOW, IN CONDUIT OR TREATMENT PLANT 50050 1

0 0

EFFLUENT GROSS VALI UE NDED UE QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

EX FREQUENCY OF ANALYSIS SAMPLE TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS SAMPLE MEASUREMENT 7.4 9.0 12 SU 0

16/31 THREE/

WEEK GRAB GRAB PERMIT REQUIREMENT 6.0 MINIMUM 9.0 MAXIMUM SAMPLE MEASUREMENT PERMIT.

REQUIREMENT 68 380 MO.AVG 97 1250 DAILY MX 10 14 26 LBS/DY 19 MGIL 0

4/31 GRAB 30 100 MO AVG DAILY MX WEEKLY GRAB SAMPLE

<44

<54

<6 19 T 4/31 GRAB MEASUREMENT PERMIT.

190.

250 LBS/DY 26 15

20.

MG/L WEEKLY GRAB UE REURMENT.

MAVG" DAILY MX

";I.MO'AVG "

DAILY MX

='"""

THRU UE SAMPLE MEASUREMENT 0.823 0.893 03

  • t 0

31/ 31 TOTALZ TOTALZ PERMIT REQUIREMENT REPORT*.**

REPORT.

MO AVG DAILY MX MGD SEE PERMIT SAMPLE MEASUREMENT PERMIT REQUIREMENT 4

4

+

I-I 4

I-I SAMPLE MEASUREMENT

... PERMIT REQUIREMENT:

4

~l l.~

4 -

SAMPLE MEASUREMENT PERMIT REQUIREMENT NAMETITLE PRINCIPAL EXECUTIVE OFFICER I Cetify under penalty of law that thi document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel t~h J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer information, the information submitted is, to the best of my knowledge and belief, true, PrincipalEnvironmentalEngineer Site Vice President accurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE

}information, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Factf/tv Name/Location it Different?

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE SB-A SODDY - DAISY TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01 )

TN0026450 II 107 G I F-FINAL ERMIT NUMBER DISCHARGE NUMBER METAL CLEANING WASTE POND

{

MONITORING PERIOD I

EFFLUENT Form Approved.

OMB No. 2040-0004 I YEAR MO DAY YEAR M0 DAY From [i07 07 01 To 07 07 31 NO DISCHARGE FXj3 NOTE: Read instructions before completing this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE I

AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS PH SAMPLE12 MEASUREMENT 00400 1

0 0

PERMIT 6.0 9.0 SU DAILY GRAB REQUIREMENT

"""MNIU EFFLUENT GROSS VALUE MINIMUM MAXIMUM SOLIDS, TOTAL SUSPENDED SAMPLE

  • 9 MEASUREMENT 00530 1

0 0

PERMIT I....

3*0 MG/L

-I

  • DAILY COMPOS EFFLUENT GROSS VALUE REQUIREMENT

" "DAILY MX OIL AND GREASE SAMPLE

  • 9 MEASUREMENT 00556 1

0 0

PERMIT' 5

MG/L DAILY GRAB REQUIREMENT I

" i:i 1

" '1",'"i:

'l EFFLUENT GROSS VALUE REQUIREMENT DAILY MX PHOSPHORUS, TOTAL (AS P)

SAMPLE

    • 19 MEASUREMENT 00665 1

0 0

PERMIT

  • MG/L DAILY COMPOS EFFLUENT GROSS VALUE REQUIREMENT*

DAILY MX COPPER, TOTAL (AS CU)

SAMPLE DAILY 19 MEASUREMENT 01042 1

0 0

PERMIT 1"*********..

1.0 MG/L DAILY COMPOS EFFLUENT GROSS VALUE REQUIREMENT IRNTOA_(SE)SMPE_*DAILY MX IRON, TOTAL (AS FE)

SAMPLE19 MEASUREMENT 01045 1

0 0

PERMIT i "

1.0 MG/L DAILY.

COMPOS EFFLUENT GROSS VALUE REQUIREMENTDAILY MX FLOW, IN CONDUIT OR THRU SAMPLE 03***

TREATMENT PLANT MEASUREMENT 03 50050 1

0 0

PERMIT REPORT REPORT MGD DAILY CALCTD EFFLUENT GROSS VALUE REQUIREMENT MO AVG DAILYMX NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my

(

TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel A

f A

hi J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer information, the information submitted is, to the best of my knowledge and belief, true.

423 843-6700 07 08 14 Site Vice President accurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE F

information, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3/99)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

_1INTEROFFICE!SB-2A)

SODDY - DAISY TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYS'HEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

PERMTNUMBE 264G G

F- -FINAL L2 RMI NUMBER~

DICAG UJE RECYCLED COOLING WATER Form Approved.

OMB No. 2040-0004 MONITORING PERIOD 7

EFFLUENT o YEAIR MO DAY YEAR MO DAY From 107 07 01 To 107 07 31j ATTN: Stephanie A. Howard

  • .. NO DISCHARGE F

NOTE: Read instructions before completinq this form.

PARAMETER 1

QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE PARA METE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.

SAMPLE 04 CENTIGRADE MEASUREMENT 04 04 00010 Z

0 0

PERMIT DEGC DEGC DAILY GRAB-4 INSTREAM MONITORING REQUIREMENT.A.

I.

M.X 38.3L" D

PH SAMPLE MEASUREMENT 12 00400 1

0 0

PERMIT 6.0 9.0 su WEEKLY GRAB EFFLUENT GROSS VALUE REQUIREMENT....

I l

.l'll tll l " Il Il" lI

' :="M IN IM U M.

l M A X IM U M

  • l:....

SOLIDS, TOTAL SUSPENDED SAMPLE 19 MEASUREMENT 19 00530 1

0 0

PERMIT

.30 MGIL DAILY COMPOS REQUIREMENT EFFLUENT GROSS VALUEREUDAILY MX*_:".

DAILY MX OIL AND GREASE SAMPLE 19 MEASUREMENT 19 00556 1

0 0

PERMIT 15 MG/L DAILY GRAB EFFLUENT GROSS VALUE REQUIREMENT DAILY MX FLOW, IN CONDUIT OR THRU SAMPLE 03***

TREATMENT PLANT MEASUREMENT 03 50050 1

0 0

PERMIT REPORT REPORT MGD DAILY CALCTD.

EFFLUENT GROSS VALUE MO AVG DAILY MX CHLORINE, TOTAL RESIDUAL SAMPLE

                        • 19 MEASUREMENT 19 50060 1

0 0

PERMIT 0.10 MGIL WEEKLY GRAB-4 EFFLUENT GROSS VALUE REQUIREMENT DAILY MX SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my A.

l l

TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel

)

J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer information, the information submitted is, to the best of my knowledge and belief, true, 423 843-6700 07 08 14 Site Vice President accurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE information, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3/99)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

___L (INTEROFFICE!SB-2A).

)

SODDY - DAISY TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

DISCHARGE MONITORING REPORT (DMR)

TN0026450

}

110 T PERMIT NUMBER LDISCHARGE NUMBER MONITORING PERIOD YEAR M

DAY YEAR MO DAY From 07 07 1o To 07 07 31 MAJOR Form Approved.

(SUBR 01)

OMB No. 2040-0004 F - FINAL RECYCLED COOLING WATER EFFLUENT NO DISCHARGE NOTE: Read instructions before completinq this form.

NCENTRATION NO.

FREUENCYý SAMPLE EX OF TYPE MAXIMUM UNITS ANALYSIS ATTN: Stephanie A. Howard PARAMETER QUANTITY OR LOADING QUALITY OR COI AVERAGE MAXIMUM UNITS MINIMUM AVERAGE IC25 STATRE 7DAY CHR SAMPLE CERIODAPHNIA MEASUREMENT 23 TRP3B 1

0 0

PERMIT "45.2 :

PERCENT SEMI.COMPOS EFFLUENT GROSS VALUE REQUIREMENT MINIMUM".-ANNUAL IC25 STATRE 7DAY CHR SAMPLE MINIMUM*

23NUAL PIMEPHALES MEASUREMENT 23 TRP6C 1

0 0

"PERMIT 45.2..*:**.

PERCENT SEMI COMPOS EFFLUENT GROSS VALUE REQUIREMENT MINIMUM ANNUAL SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT.

SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my

.,.LIl.--

I TELEPHONE DATE dtirection or supervision in accordance with a system designed to assure that qualified personnel TE EP ON DATE J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer information, the information submitted is, to the best of my knowledge and belief, true.

423 843-6700 07 08 14 Site Vice President accurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE information. including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

_LINTEROFFICýE SB-2A).

SODDY - DAISY TN 37384

Facilit, TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NAl IONAL POLLUrANI UISCHARGE ELIMINATION SYsI EM (NPVLc5)

DISCHARGE MONITORING REPORT (DMR)

I TN0026450 116 G PERMIT NUMBER I lSCHARGE'NU"BER MONITORING PERIOD YEAR M

DAY I YEAR MO DAY From 07 07 01 To 07 07 31 MAJOR Form Approved.

(SUBR 01)

OMB No. 2040-0004 F - FINAL BACKWASH EFFLUENT

..* NO DISCHARGE NOTE: Read instructions before completinq this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

EX FREQUENCY SAMPLE OF TYPE ANALYSIS 1-9 i

9 AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS DEBRIS, FLOATING (SEVERITY)

SAMPLE 0

9A 0

1 / 31 VISUAL MEASUREMENT 01345 1

0 0

PERMIT,_

REPORT PASS=O SEE VISUAL.

EFFLUENT GROSS VALUE REQUIREMENT FAIL=I PERMIT

__MO TOTAL PERMIT OIL AND GREASE VISUAL SAMPLE 0

94 1/31 VISUAL MEASUREMENT 84066 1

0 0

PERMIT REPORT YES=I SEE VISUAL EFFLUENT GROSS VALUE REQUIREMENT MO TOTAL NO=0 PERMIT SAMPLE MEASUREMENT PERMIT:

.REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT

.PERMIT..

REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel,

.¶,*. 'i J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer Site Vice President information, the information submitted is. to the best of my knowledge and belief, true.

423 843-6700 07 08 14 accurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE TYPED OR PRINTED information, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED_______________OR________PRINTED__________________CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

Operations performs visual inspections for floating debris and oil and grease during all backwashes.

EPA Form 3320-1 (REV 3/99)

Previous editions may be used Page 1 of I

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

.(INTEROFFICýE S B-2A).

)

SODDY - DAISY TN 37384 Facility TVA - SEOUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

TN0026450

.117 G F-FINAL PERMIT NUMBER

[DISCHARGE NUMBER BACKWASH Form Approved.

OMB No. 2040-0004 I M IT PERIQD EFFLUENT YEAR M0 DAY Y

O NO DISCHARGE NOTE: Read instructions before completmnq this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS DEBRIS, FLOATING (SEVERITY)

SAMPLE 0

9A 0

1 / 31 VISUAL MEASUREMENT 01345 1

0 0

PERMIT REPORT.

PASS=0 SEE VISUAL:

EFFLUENT GROSS VALUE REQUIREMENT MOTOTAL FAIL=1 PERMIT OIL AND GREASE VISUAL SAMPLE 0

94 0

1 / 31 VISUAL MEASUREMENT 84066 1

0 0

PERMIT

REPORT, YES=I SEE VISUAL EFFLUENT GROSS VALUE REQUIREMENT MO TOTAL NO=0 PERMIT SAMPLE MEASUREMENT PERMIT..

REQUIREMENT SAMPLE*

PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAMEfTITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my

/'

I*

TELEPHONE DATE Uirection or supervision in accordance with a system designed to assure that qualified personnel

,/i)CI J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer 08 information, the information submitted is, to the best of my knowledge and belief, true, 423 843-6700 07 08_14 accurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE

_ ARE

_____0__DA]_

TYPED O information, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO TYPED OR PRINTED CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

Operations performs visual inspections for floating debris and oil and grease during all backwashes.

EPA Form 3320-1 (REV 3199)_

Previous editions may be used Page 1 of 1

P ERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 (INTEROFFICE SB-2A)

SODDY - DAISY TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR Form Approved.

DISCHARGE MONITORING REPORT (DMR

)

OMB No. 2040-0004 (SUBR 01)0MNo20004 TN0026450 118 G F-FINAL PERMIT NUMBER DISCHARGE NUMBER WASTEWATER & STORM WATER I

I MONITORINQ PFRIOf-I EFFLUENT LYEAR FMO A1-YEA

.Y -

MO1 DAY From 0 70

.1 To 07 NO DISCHARGE NOTE: Read instructions before completinq this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS OXYGEN, DISSOLVED (DO)

SAMPLE 19 MEASUREMENT 00300 1

0 0

- PERMIT

.2.0.

.*MGIL TWICE/

GRAB EFFLUENT GROSS VALUE REQUIREMENT

  • DAILY MN WEEK SOLIDS, TOTAL SUSPENDED SAMPLE 19 MEASUREMENT 00530 1

0 0

PERMIT 100 MGIL TWVICE/

GRAB REQUIREMENT

DI~__xWE EFFLUENT GROSS VALUE DAILY MX WEEK SOLIDS, SETTLEABLE SAMPLE 25 MEASUREMENT 00545 1

0 0

PERMIT

- 1.0.

ML/L ONCE/

GRAB EFFLUENT GROSS VALUE REQUIREMENT DAILY MX MONTH FLOW, IN CONDUIT OR THRU SAMPLE TREATMENT PLANT MEASUREMENT 03 50050 1

0 0

PERMIT REPORT-

REPORT, MGD ONCE/

ESTIMA EFFLUENT GROSS VALUE REQUIREMENT.

MO "AVG DAILY MX

.B SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my I

TELEPHONE DATE d_-irection or supervision in accordance with a system designed to assure that qualified personnel J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or6nnel V'-

T L P O ED E

persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer information, the information submitted is. to the best of my knowledge and belief. true.

PrincipalEnvironmentar 423 843-6700 07 08 14 Site Vice President accurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE information. including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED 1

CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

During this reporting period, there has been no flow from the Dredge Pond other than that resulting from rainfall.

EPA Form 3320-1 (REV 3/99)

Previous editions may be used Page 1 of 1