August 13, 2007 Rick Libra, BWRVIP Chairman DTE Energy Fermi Nuclear Plant (M/S 280 OBA) 6400 N. Dixie Highway Newport, MI 48166-9726

SUBJECT:

ACKNOWLEDGMENT OF WITHDRAWAL OF BWRVIP-41 AND BWRVIP-138 REPORTS (MD0048)

Dear Mr. Libra:

By letter dated July 18, 2007, the Boiling Water Reactor Vessel and Internals Project (BWRVIP) informed the Nuclear Regulatory Commission (NRC) staff of the withdrawal of the following two reports:

BWRVIP-41, Revision 1, BWR Jet Pump Assembly Inspection and Flaw Evaluation Guidelines, August 2005 BWRVIP-138, Updated Jet Pump Beam Inspection and Flaw Evaluation Guidelines, December 2004.

The NRC staff submitted requests for additional information (RAIs) in its letter dated May 12, 2006, concerning the two reports. In order to address the NRC staffs RAIs, the BWRVIP is performing detailed analyses of the jet pump beams. However, due to performing these analyses, the agreed upon date, specified in the NRC letter dated February 24, 2006, for the BWRVIP submittal of their responses to the NRC staffs RAIs has passed. Therefore, the BWRVIP is withdrawing the two reports, and the applicable licensees will continue to implement the NRC approved guidance in BWRVIP-41 and any additional guidance in BWRVIP-41, Revision 1 and BWRVIP-138 which is more conservative than the previously approved guidance.

The NRC staff acknowledges the withdrawal of the BWRVIP-41, Revision 1 and BWRVIP-138 reports, and will discontinue the review of the subject reports. The NRC staff also understands that the BWR licensees will use the BWRVIP-41 report approved by the staff in its letter dated February 4, 2001, and any guidance in the BWRVIP-41, Revision 1 and BWRVIP-138 reports that is more conservative than the BWRVIP-41 report what was approved by the NRC in its letter dated February 4, 2001, as a basis for the inspection and evaluation of BWR jet pumps.

Upon completion of the analyses, the BWRVIP will incorporate the results of the analyses and the RAI responses into new revisions of the two reports, and submit these reports to the NRC staff for approval.

If you have any questions regarding this letter, please contact Mr. John Honcharik of my staff at (301) 415-1157.

Sincerely,

/RA/ Simon Sheng for Matthew A. Mitchell, Chief Vessels & Internals Integrity Branch Division of Component Integrity Office of Nuclear Reactor Regulation Project No. 704 cc: BWRVIP Service List Upon completion of the analyses, the BWRVIP will incorporate the results of the analyses and the RAI responses into new revisions of the two reports, and submit these reports to the NRC staff for approval.

If you have any questions regarding this letter, please contact Mr. John Honcharik of my staff at (301) 415-1157.

Sincerely,

/RA/ Simon Sheng for Matthew A. Mitchell, Chief Vessels & Internals Integrity Branch Division of Component Integrity Office of Nuclear Reactor Regulation Project No. 704 cc: BWRVIP Service List DISTRIBUTION:

Public DCI RF CVIB JTsao PPatnaik JWhite, RI GHopper, RII DHills, RIII JClark, RIV ADAMS ACCESSION NO.: ML072250542 OFFICE DCI/CVIB DCI/CVIB NAME JHoncharik MMitchell DATE 8/7/2007 8/13/2007 OFFICIAL RECORD COPY

cc:

Randy Stark, EPRI BWRVIP Integration Manager Raj Pathania, EPRI BWRVIP Mitigation Manager Ken Wolfe, EPRI BWRVIP Repair Manager Larry Steinert, EPRI BWRVIP Electric Power Research Institute 3420 Hillview Ave.

Palo Alto, CA 94303 Paul J. Davison BWRVIP Executive Oversight Committee PSEG Nuclear, LLC Salem/Hope Creek Nuclear Station 11 Yubas Ave.

Burlington, NJ 08016 Bob Geier, Technical Chairman BWRVIP Assessment Committee Exelon Corporation Cornerstone II at Cantera 4300 Winfield Rd.

Warrenville, IL 60555 Denver Atwood, Technical Chairman BWRVIP Repair Focus Group Southern Nuclear Operating Co.

Post Office Box 1295 40 Inverness Center Parkway (M/S B031)

Birmingham, AL 35242-4809 Jeff Goldstein, Technical Chairman BWRVIP Mitigation Committee Entergy Nuclear NE 440 Hamilton Ave. (M/S K-WPO-11c)

White Plains, NY 10601 Charles J. Wirtz, Chairman Technical Chairman BWRVIP Integration Committee FirstEnergy Corp.

Perry Nuclear Power Plant (M/S A250) 10 Center Road Perry, OH 44081 Amir Shahkarami, Executive Chairman BWRVIP Integration Committee Exelon Corporation Cornerstone II at Cantera 4300 Winfield Rd.

Warrenville, IL 60555-4012 Robert Carter, EPRI BWRVIP Assessment Manager Jeff Landrum, EPRI BWRVIP Inspection Manager EPRI NDE Center P.O. Box 217097 1300 W. T. Harris Blvd.

Charlotte, NC 28221 Richard Anderson, Executive Chairman BWRVIP Assessment Committee Vice President, Nuclear FirstEnergy Service Co.

Perry Nuclear Power Plant (M/S A-PY-290) 10 Center Road Perry, OH 44081 Joe Donahue BWRVIP Executive Oversight Committee V. P., Nuclear Engineering & Services Progress Energy, Inc.

410 S. Wilmington St. (M/S PEB6)

Raleigh, NC 27601-1849 Dennis Madison BWRVIP Executive Oversight Committee Site Vice President Southern Nuclear Operating Co.

Edwin I. Hatch Nuclear Plant US Hwy 1 N Baxley, GA 31515-2010