August 1, 2007 Mr. William Bonzer, Reactor Manager University of Missouri-Rolla 226 Fulton Hall Rolla, MO 65409-0170
SUBJECT:
UNIVERSITY OF MISSOURI - ROLLA RESEARCH REACTOR FACILITY -
REQUEST FOR ADDITIONAL INFORMATION REGARDING CHANGES TO TECHNICAL SPECIFICATIONS (TAC NO. MD5976)
By letter dated April 9, 2007, you requested changes to the University of Missouri, Rolla, Research Reactor Technical Specifications. The Nuclear Regulatory Commission (NRC) staff has reviewed the information provided and has determined that additional information is needed to complete its review.
American Nuclear Society Standard 15.1, Development of Technical Specifications for Research Reactors, Section 6.4, Procedures, states [s]ubstantive changes to the previous procedures shall be made effective only after documented review by the review group and approval by Level 2 or designated alternates. Minor modifications to the original procedures which do not change their original intent may be made by Level 3 or higher but the modifications must be approved by Level 2 or designated alternates within 14 days. Your proposed amendment states [c]hanges that do not change the original intent of the procedures may be made with the approval of the Facility Manager. Please clarify whether the minor modifications need to be approved by Level 2 (Reactor Facility Director) and time to be approved after they are modified by the Facility Manager.
In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your license amendment request. As discussed with you, we understand that you intend to respond to this request for additional information within 30 days of receipt of this letter.
Should you have any questions, please contact me at 301-415-1128 or John Nguyen at 301-415-4007.
Sincerely,
/RA/
Marvin Mendonca, Senior Project Manager Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-123 License No. R-79
August 1, 2007 Mr. William Bonzer, Reactor Manager University of Missouri-Rolla 226 Fulton Hall Rolla, MO 65409-0170
SUBJECT:
UNIVERSITY OF MISSOURI - ROLLA RESEARCH REACTOR FACILITY -
REQUEST FOR ADDITIONAL INFORMATION REGARDING CHANGES TO TECHNICAL SPECIFICATIONS (TAC NO. MD5976)
By letter dated April 9, 2007, you requested changes to the University of Missouri, Rolla, Research Reactor Technical Specifications. The Nuclear Regulatory Commission (NRC) staff has reviewed the information provided and has determined that additional information is needed to complete its review.
American Nuclear Society Standard 15.1, Development of Technical Specifications for Research Reactors, Section 6.4, Procedures, states [s]ubstantive changes to the previous procedures shall be made effective only after documented review by the review group and approval by Level 2 or designated alternates. Minor modifications to the original procedures which do not change their original intent may be made by Level 3 or higher but the modifications must be approved by Level 2 or designated alternates within 14 days. Your proposed amendment states [c]hanges that do not change the original intent of the procedures may be made with the approval of the Facility Manager. Please clarify whether the minor modifications need to be approved by Level 2 (Reactor Facility Director) and time to be approved after they are modified by the Facility Manager.
In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your license amendment request. As discussed with you, we understand that you intend to respond to this request for additional information within 30 days of receipt of this letter.
Should you have any questions, please contact me at 301-415-1128 or John Nguyen at 301-415-4007.
Sincerely,
/RA/
Marvin Mendonca, Senior Project Manager Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-123 License No. R-79 DISTRIBUTION:
PUBLIC RidsNrrDprPrta RidsNrrDprPrtb RTR Reading ACCESSION NO.: ML071980025 TEMPLATE No.: NRR-106 OFFICE PRTA PRTA:LA PRTB:PM PRTA:BC NAME J Nguyen EHylton egh MMendonca mm DCollins dsc DATE 7/16/07 8/1/07 8/1/07 8/1/07
University of Missouri - Rolla Docket No. 50-123 cc:
Dr. Mariesa Crow, Dean School of Mines and Metallurgy 305 McNutt Hall University of Missouri-Rolla Rolla, MO 65401 Dan Estel University of Missouri-Rolla Nuclear Reactor Facility 1870 Miner Circle Rolla, MO 65409-0630 Mr. Michael Chapman Missouri Office of Homeland Security P.O. Box 749 Jefferson City, MO 65102 Planner, Dept of Health and Senior Services Section for Environmental Public Health 930 Wildwood Drive, P.O. Box 570 Jefferson City, MO 65102-0570 Deputy Director for Policy Department of Natural Resources 1101 Riverside Drive Fourth Floor East Jefferson City, MO 65101 A-95 Coordinator Division of Planning Office of Administration P.O. Box 809 State Capitol Building Jefferson City, MO 65101 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611