ML071940457
| ML071940457 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 07/11/2007 |
| From: | Christian Jacobs NRC/NRR/ADRO/DLR |
| To: | Medenciy C Wolf Creek |
| References | |
| Download: ML071940457 (3) | |
Text
01ýristian a666i - Re: CR Fire CDF Value Clarification CrsinJcb-ReCRFrCD alCf iaio I
From:
Christian Jacobs To:
chmeden@WCNOC.com Date:
7/11/2007 1:28:45 PM
Subject:
Re: CR Fire CDF Value Clarification Thanks Charlie.
I'm forwarding to Bob, but this issue should be considered closed now.
Chris Christian Jacobs Environmental Project Manager Division of License Renewal U.S. Nuclear Regulatory Commission 301-415-3874 O-12D1 1 cjj@nrc.gov
>>> "Medenciy Charlie M" <chmeden@WCNOC.com> 07/11/07 10:45 AM >>>
The value of 2.22E-6 reported in the ER for the fire re-analysis is correct, and that the CR fire CDF actually increased in the fire re-analysis from 1.43E-06 to 2.22E-06.
Original Message -----
From: Robert Palla nrc.gov
Sent: Wednesday, July 11, 2007 8:27 AM To: Christian Jacobs Cc: bmrowca@islinc.com
Subject:
Fwd: RE: CR Fire CDF Value Clarification Chris - In addition to confirming that the IPEEE control room fire CDF reported in the ER was incorrect (should have been 1.43E-6 rather than 6.31 E-5), it would be a good idea to have WCNOC also confirm that the value of 2.22E-6 reported in the ER for the fire re-analysis is correct, and that the CR fire frequency actually increased in the fire re-analysis (the ER states that it decreased, but that statement appears incorrect given the correction to the IPEEE value). Bob
>>> Christian Jacobs 07/11/2007 8:41 AM >>>
- Bob, See attached email from Charlie (Wolf Creek). He confirmed that they used the incorrect number, and that you and Bruce are correct in using the IPEEE number. I'm thinking I can just add the email to ADAMS and this will resolve the issue. I don't think I need to ask them to send this info under oath and affirmation since the 1.43 number is something that we can can reference from IPEEE. Do you agree?
Chris Christian Jacobs Environmental Project Manager Division of License Renewal U.S. Nuclear Regulatory Commission
Christian Jacobs - Re: CR Fire CDF Value Clarification P;i6l e 301-415-3874 O-12D1 1 cjj @ nrc.gov
c:\\temp\\GWLOOO1.MPP j
Mail Envelope Properties (4695134D.423 : 2: 36278)
Subject:
Creation Date From:
Created By:
Re: CR Fire CDF Value Clarification 7/11/2007 1:28:45 PM Christian Jacobs cij@nrc.gov Recipients WCNOC.com PM chmeden Post Office Files MESSAGE Action Transferred Date & Time 7/11/2007 1:29:10 Delivered Route WCNOC.com Size 1777 Date & Time 7/11/2007 1:28:45 PM Options Auto Delete:
No Expiration Date:
None Notify Recipients:
Yes Priority:
Standard ReplyRequested:
No Return Notification:
Send Mail Receipt when Undeliverable Concealed
Subject:
Security:
To Be Delivered:
Status Tracking:
No Standard Immediate Delivered & Opened