ML071580738

From kanterella
Jump to navigation Jump to search
Request for Change to Technical Specifications Steam Generator Feedwater Pump Trip, Feedwater Isolation Valve, Response Time Testing and Containment Cooling System
ML071580738
Person / Time
Site: Salem  PSEG icon.png
Issue date: 05/30/2007
From: Tosch K
State of NJ, Dept of Environmental Protection, Bureau of Nuclear Engineering
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
S06-10
Download: ML071580738 (2)


Text

Wtate of New Arzeq DEPARTMENT OF ENVIRONMENTAL PROTECTION JON S. CORZINE Division of Environmental Safety and Health LISA P. JACKSON Governor Commissioner Radiation Protection and Release Prevention Element Bureau of Nuclear Engineering P. 0. Box 415 Trenton, New Jersey 08625-0415 Tel (609) 984-7700 Fax (609) 984-7513 May 30, 2007 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Dear Sir:

Subject:

Salem Generating Station Units 1 and 2 Docket Nos. 50-272 and 50-311 License Change Request S06-10 Request for Change to Technical Specifications Steam Generator Feedwater Pump Trip, Feedwater Isolation Valve Response Time Testing and Containment Cooling System PSEG Nuclear LLC submitted the proposed change to the Salem Technical Specifications by letter to the NRC dated March 16, 2007. The proposed amendment involves (1) new technical specification (TS) surveillance requirements for Steam Generator Feedwater Pump trip and Feedwater Isolation Valve closure, and (2) revised TS surveillance requirements for Containment Fan Cooler Unit flow.

The BNE has no comments on the proposed change. If you need to discuss this subject further, please contact Elliot Rosenfeld at (609) 984-7548.

Sincerely,

//

Kent W. Tosch, Manager Bureau of Nuclear Engineering New Jersey Is An Equal Opportunity Employer 0 Printedon Recycled Paper and Recyclabl/