{{#Wiki_filter:Final Submittal (Blue Paper) SEQUOYAH APRIL/MAY 2007 EXAM EXAM NOS. 05000327/2007301 AND 05000328/2007301 APRIL 9 - 11, 2007 AND MAY 9, 2007 (written) 1. Administrative JPMs 2. In-plant JPMs 3. Control Room JPMs (simulator JPMs)


( PREPARED! REVISED BY: VALIDATED BY: APPROVED BY:

JPM 8.1 .a Page 1 of 10 Rev 0 SEQUOYAH NUCLEARPLANT JOB PERFORMANCE MEASURE B.1.a Raise Power to 10-3 % Original Signatures on File Date! Date! Date! (Operations Training Manager) CONCURRED:

(Operations Representative) Date! /

  • Validation not required for minor enhanceme nts, procedure Rev changes that

do not affect the JPM, or individual step changes that do not affect the flow of the JPM.

    • Operations Concurrence required for new JPMs and changes that affect the

flow of the JPM (if not driven by a procedure revision).

/ ( JPM B.1.a Page 2 of 10 RevO NUCLEAR TRAINING REVISION/USAGE LOG Revision Description Pages Prepared/ Number Of Revision V Date Affected Revised Bv: 0 Initial issue Y 3/08/07 Ali RH Evans I I i I v - Specify if the JPM change will require another validation (Y or N). See cover sheet for criteria.

JPM B.1.a Page 3 of 10 Rev 0 ( SEQUOYAH NUCLEAR PLANT RO/SRO JOB PERFORMANCE MEASURE Task: Raise Reactor Power to 10.3% JAITA task # : 0010190101, Operate the Control Rod Drive System to bring the reactor critical 0010100101, Manually open the Reactor Trip Breaker from the Controi Room 3110140601, Respond to Continuous Rod Withdrawal per AOP-C.01 KiA Ratings: 192008 K1.08 001K5.18 001A3.08 001AK1.01 001AA2.05 3.5/3.6 4.2/4.3 3.9/4.0 3.4'/3.7 4.4/4.6 Task Standard: Reactor is tripped in response to uncontrolled rod withdrawal. In-Plant _ x Evaluation Method: Simulator _--!O-_~

=======================================================================

( Performer: NAME Start Time Performance Rating: SAT UNSAT Performance Time Finish Time Evaluator: / SIGNATURE DATE

=======================================================================

COMMENTS

( JPM B.1.a Page 4 of 10 Rev 0 SPECIAL INSTRUCTIONS TO EVALUATOR: 1. Sequenced steps identified by an "s" 2. Any UNSAT requires comments 3. Ensure operator performs the following required actions for SELF-CHECKING; a. Identifies the correct unit, train, component, etc. b. Reviews the intended action and expected response. c. Compares the actual response to the expected response. 4. Initialize simulator to IC-91 5. Ensure Audio-Count Rate Multiplier is set on the 'xt ' scale 6. Acknowledge any associated alarms. Initialize Simulator to IC-91 Validation Time: CR. 21 mins Loca l ToolS/Equipment/Procedures Needed: 0-GO-2 Mark Up, 0-SO-B5-1 Mark Up, Counts Doubling table, 11M Plot References' Reference Title Rev No. A. 0-GO-2 Unit Startup from Hot Standbv to Reactor Critical 26 B. 0-50*85*1 Control Rod Drive Svstem 32 C. AOP-C.Ol Rod Control System Malfunction 16

=== =============~======================================================= ===

READ TO OPERATOR DIRECTIONS TO TRAINEE: I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initialing cues and reports on other actions when directed by you. When you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you. INITIAL CONDITIONS: A reactor startup is in progress in accordance with 0-GO-2, Reactor Startup. The following conditions exist:

All shutdown bank rods are fully withdrawn.

Control Bank "0 " is at 127 steps.

The estimated critical pos ition is 155 steps on Control Bank "0".

Most rece nt 11M predicts 150 steps on Cont rol Bank 0

You are at the e" doubling of source range cou nts .

All precautions, limitations, prerequisites and preceding steps for performance of the task have been met or successfully performed. INITIATING CUES: The Unit Supervisor directs you to continue with the reactor startup and withdraw control rods to criticality and increase power to take critical data in accordance with 0-GO-2, Unit Startup from Hot Standby to Reactor Critical, section 5.2, beginning at Step 55, and 0-SO-85-1 section 6.3, step 41. You are to notify the Unit Supervisor when critical data has been taken.

STEP 1.: [55] ( ( Job Performance Checklist: STEP/STANDARD If ICRR plot trend indicates acceptable ECC, Then initiate rod withdrawal using SO-85-1 to seventh doubling range (App. C) or criticality. STANDARD: Candidate determines that 7 doubling is approximately 2400 CPS on each SR channel. Determines that ICRR indicates acceptable ECC (+/- 1000 pcm of estimated). Initiates rod withdrawal by placing IN-HOLD* OUT switch1 -HS-85-5111 to the OUT position. NOTE: Refer to jpm step 3 for critical step on determining reactor is critical. COMMENTS: Procedure note prior to step 56: Steps 5.3(56) th rough 5.3(58) may be repeated as necessary if rod motion is stopped prior to reaching doubling range or criticality. STEP 2. [56] When any of the following conditions are met:

SR count rate reaches or exceeds seventh doubling range determined in Appendix C or

Bank 0 rods reach fully withdrawn position or

Operators or Reactor Engineer determine that rod motion should be stopped THEN STOP outward rod motion STANDARD : This step will NOT be applicable at this time COMMENTS: JPM B.1 .a Page 5 of 10 RevO SATIUNSAT _SAT _ UNSAT Start Time_ _ Critical Step _ SAT _ UNSAT Note : Candidate may stop rod withdrawal when P*6 is received. When P*6 is received, action will be taken per procedure step 62 of D-GO*2

STEP 3. [57] If Reactor is critical, then go to step 5.2(59) (NA Step 5.2(58). - SAT STANDARD: Performer determines the reactor is critical by observing a stable - UNSAT startup rat e with no addition of positive reactivity prior to reaching 10--3%power and procedure step 58 will be NA. Cue: If necessary, ask operator If the reactor Is critical. Critical Step NOTE: If applicant states that the reactor Is NOT critical, this is co nsidered UNSAT performance. COMMENTS: STEP 4. [59] If any of the following conditions exist: - SAT

Criticai conditions cannot be achieved within the +/- 750 pcm - UNSAT termination band or

Critical conditions cannot be achieved within the +/- 1000 pcm - allowable limits or,

Critical conditions cannot be achieved above rod insertion limit or

Reactor startup must be aborted for other reasons, Then perform the following to abort reactor startup:

STOP rod withdrawal

INITIATE insertion of control banks

PERFORM Appendix D, Actions if reactor startup must be aborted

DO NOT continue this section STANDARD: Candidate determines this step does NOT apply COMMENTS: STEP 5. [60] If reactor is subcritical with rods at fully withdrawn position, then - SAT perform Appendix E Actions if reactor subcritical with rods fully UNSAT withdrawn. - STANDARD: Candidate determines that this step is NA COMMENTS: ( (


- ._- -_. - _._--

Job Performance Checklist : STEP/STANDARD JPM B.1.a Page 6 of 10 RevO SATIUNSAT

STEP 6. [61] If the reactor is critical with SUR less than 0.3 DPM, and - SAT Intermediate Range NIS <P-6 (1E*4%), then perform the following: - UNSAT

  • If Bank D control Rods are BELOW the fully withdrawn position,

then operate control rods to establish a positive SUR of approximately 0.3 DPM. STANDARD: Candidate evaluates IR SUR and if necessary, withdraws control bank D to establish a 0.3 DPM SUR COMMENTS: Procedure notes prior to step 62: 1. Blo cki ng the SRM trip with HS*92-5001 and HS-92-5002 will disable the detector outputs and rem ove the audio count rate signa l 2. Step 5.3(62) may be performed at time of criticality, if re~u ired, Source Range reactor trip must be BLOCKED before trip setpoint of 10 CPS - STEP 7. [62] When annunciator window XA-55*4A, window D-2 is iit, then - SAT

Record both Source Range readings - UNSAT

Record both Intermediate Range readings

  • Verify a minimum of 1 IRM channel greater than or equal to 1F 4%

RTP.

Block source range reactor trip by momentarily placing HS-92- Critical Step 5001 and HS-92-5002 SRM TRIP RESET-BLOCK handswitches to BLOCK.

  • Verify annunciator window XA-55-4A, C-1, is lit
  • Select NR-45 to record 1 IR and 1 PR channel
  • Adjust NR-45 chart speed as desired.

STANDARD: Acknowledge P*6 annunciator; Record SR and IR indications on MCB, and verify IR indication > 1E,4%. Places both switches in BLOCK, and observes annunciator XA-55-4A-C1 Selects one IR and one PR indication on NR-45 Cue: If the candidate reports that Source Range High Flux Tri ps have been blocked, acknowledge and provide direction to raise reacto r power t01x10*3% power to o btain critical data COMMENTS: ( ( Job Performance Checklist: STEP/STANDARD JPM B.1.a Page 7 of 10 Rev 0 SAT/UNSAT

Job Performance Checklist: STEP/STANDARD JPM B.l.a Page 8 of 10 RevO SAT/UNSAT ( STEP 8. [63] Ensure PA announcement made to notify plant personnel when - SAT the reactor is critical. - UNSAT STANDARD: Announces criticality over the PA system COMMENTS: Note prior to step 64: When T-avg is less than 551 degrees F and Tavg-Tref dev iation alarm Is lit, SR 4.1.1.4.b requires verifying lowest T-AVG greater than or equal to 541 degrees F at least once every 30 minutes. STEP 9. [64] If Tavg-Tref alarm (M-5A window C-6) is lit, and Tavg is less than - SAT 551 degrees F, Then perform 0-SI-SXX-068-127.0 to satisfy SR 4.1 .1.4.b, Minimum Temperature for Criticality. - UNSAT STANDARD: Candidate verifies Tavg is 547 degrees F. Cue: Another operator_will perform the surveillance COMMENTS: Booth Instructor: Insert malfunction IMF RD01 f:48 k:1 at the next rod motion. Ind ication on 1-M-4, Rod Motion Red or Green Light. STEP 10. [65] RAISE reactor power to approximately 1 X 10.3%: - SAT [65.1] If Bank 0 rods are below fUlly withdrawn position, then operate - UNSAT control rods to establish a positive SUR of approximately 0.5 DPM (not to exceed 1 DPM) STANDARD: Initiates rod withdrawal by placing IN-HOLD-OUT switch 1-HS-85- Critical Step 5111 to the OUT position. Ensures SUR is <1 DPM COMMENTS:

Job Performance Checklist: STEP/STANDARD JPM B.1.a Page 9 of 10 Rev O SAT/UNSAT ( STEP 11. Determines that Bank 0 Group 1 is stepping after releasing IN- - SAT HOLD-OUT switch - UNSAT STAND ARD: Candidate reports rod movement to SRO or attempts to insert Bank 0 rods. Determines rod movement does not stop Cue: /f candidate reports to SRO, acknowledge the report. D/rect the candidate to recommend an action COMM ENTS: STEP 12.: Trip the reactor in response to inappropriate continuous rod motion. - SAT STAN DARD: Candidate trips the reactor in response to inappropriate continuous rod - UNSAT motion. Note: Candidate may refer to AOP C.01 for tripping reactor Critical Step COMM ENTS: - End of JPM

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK) DIRECTION TO TRAINEE: I will explain the initial conditions, and state the task to be performed. All control room steps shall be performedfor this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me whenyou understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you. INITIAL CONDITIONS: A reactor startup is in progress in accordance with 0-GO-2, Reactor Startup. The following conditions exist:

All shutdown bank rods are fully withdrawn.

Control Bank "D" is at 127 steps.

The estimated critical position is 155 steps on Control Bank "D". .

Most Lecent 11M predicts 150 steps on Control Bank D

You are at the 6 th doubling of source range counts.

All precautions, limitations, prerequisites and preceding steps for performance of the task have been met or successfully performed. INITIATING CUES: The Unit Supervisor directs you to continue with the reactor startup and withdraw control rods to criticality and increase power to take critical data in accordance with 0-GO-2, Unit Startup from Hot Standby to Reactor Critical, section 5.2, beginning at Step 55, and 0-50-85-1 section 6.3, step 41. You are to notify the Unit Supervisor when critical data has been taken.

( ( (


,,-._-,--_..__._._-_..

Sequoyah Nuclear Plant Unit 0 General Operating Instructions O-GO-2 UNIT STARTUP FROM HOT STANDBY TO REACTOR CRITICAL Revision 0026 Quality Related Level of Use: Continuous Use Effective Date: 12-10-2006 Responsible Organization: OPS, Operations Prepared By: O. A. Porter Approved By: W. T. Leary Current Revision Description Revised to resolve interface problem with 0-RT-NUC-000-003.0 (PER 115799). Added contingency actions if Control Bank 0 reaches full out position. Incorporated various other enhancements. THIS PROCEDURE IMPACTS REACTIVITY

\\ SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 2 of 85 Table of Contents PRECAUTIONS AND LIMITATIONS 6 PRECAUTIONS 6 LIMITATIONS 8 PREREQUiSiTES 9 INSTRUCTIONS 12 Actions to be performed prior to a reactor startup 12 Reactor Startup after a refueling outage 21 Reactor Startup after a non-refueling outage 45 REFERENCES 3 Performance References 3 Developmental References 5 FIRST SECTION 3 Purpose 3 Scope 3 RECORDS 69 Appendix A: DELETED 70 Appendix B: MODE 3 TO MODE 2,1 REVIEW AND APPROVAL 71 Ap pendix C: DETERMING SOURCE RANGE COUNT RATE DOUBLI NG 79 Appendix D: ACTIONS IF REACTOR STARTUP MUST BE ABORTED 80 Appendix E: ACTIONS IF BANK D RODS REACH FULL OUT POSITION PRIOR TO CRITICALITY 81 1.0 1.1 1.2 2.0 2.1 2.2 3.0 3.1 3.2 4.0 5.0 5.1 ( 5.2 5.3 6.0 Source Notes 83

\\" SON UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 3 of 85 1.0 FIRST SECTION 1.1 Purpose This General Operating (GO) Instruction provides necessary actions to perform a unit startup from hot standby (Mode 3) to reactor critical (Mode 2) following a reactor shutdown or initial startup after refueling. 1.2 Scope A. This GO contains the following sections: 1. 5.1 Actions to perform prior to commencing reactor startup. 2. 5.2 Reactor startup after a refueling outage. 3. 5.3 Reactor startup after a non-refueling outage. This instruction also provides guidance for the control of reactivity associated with Xenon while the reactor is in a hot standby condition. ( 2.0 REFERENCES 2.1 Performance References A. 0-RT-NUC-000-003.0, Low Power Physics Testing B. 0-SI-OPS-000-004.0, Surveillance Requirements Petiormed on Increased Frequency with No Specific Frequency C. 0-SO-30-5, Lower Compartment Cooling Units D. 0-SI-SXX-068-127.0, RCS and Pressurizer Temperature and Pressure Limits E. 0-SO-30-6, Control Rod Drive Cooling Units F. 1-PI-OPS-000-021 .1 , Mode 1-4 Control Room Operator MCR Duty Station Shift Relief and System Status Checklist G. 2-PI-OPS-000-023.1 , Mode 1-4 Control Room Operator MCR Duty Station Shift Relief and System Status Checklists H. 1, 2-S0-3-2, Auxiliary Feedwater System I. 1,2-SI-ICC-092-N41.1, Channel Calibration of Power Range Nuclear Instrumentation System, Channel N4 1

\\.


-

-- SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 4 of 85 2.1 Performance References (continued) J. K. L. M. N. O. P. Q. R. ( S . 1, 2-SI-ICC-092-N42.2, Channel Calibration of Power Range Nuclear Instrumentation System, Channel N42 1, 2-SI-ICC-092-N43.3, Channel Calibration of Power Range Nuclear Instrumentation System, Channel N43 1,2-SI-ICC-092-N44.4, Channel Calibration of Power Range Nuclear Instrumentation System, Channel N44 0-SI-NUC-000-001.0, Estimated Critical Conditions 0-SI-NUC-000-038.0, Shutdown Margin 1, 2-SO-68-2, Reactor Coolant Pumps 1-PI-OPS-057-001.0, Functional Testing of Low Voltage Bus Cooling Oil Pumps Core-Operating Limit Report 0-PI-OPS-000-001.0, Initial Startup System Parameter Log 0-PI-OPS-301-001.0, Plant Computer Point Disablement T. OPDP-4, Annunciator Disablement U. SI-53, Specific Iodine Isotopic Activity Concentration and/or DE 1-131 Determination V. SI-407.2, Radioactive Gaseous Waste Effluent Particulate and Iodine Dose Rates from Shield and Auxiliary Building Exhausts (Weekly/Special) and Condenser Vacuum Exhaust (Special) W. 0-SI-CEM-030-415.0, Gaseous Effluent Requirements (Gross Alpha Noble Gas and Tritium) X. 0-SO-62-7, Boron Concentration Control Y. 0-SO-85-1, Control Rod Drive and Rod Position Indication System Z. OPDP-1, Conduct of Operations AA. SPP-10.0, Plant Operations Standard Program BB. SPP-3.1 , Corrective Action Program CC. Technical Requirements Manual, 3.4.7 DO. Technical Specifications, SR 4.1.1 .4.a

( ( \\, SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev, 0026 Page 5 of 85 2.1 Performance References (continued) EE. Technical Specifications, SR 4.1.1A.b 2.2 Developmental References A, GO I-1, Plant Startup from Cold Shutdown to Hot Standby B. GO I-2, Plant Startup from Hot Standby to Minimum Load C, O-GO-2-1, Plant Startup from Hot Standby to Reactor Critical D, FSAR Section 13,5 E, SPP-10A , Reactivity Management Program

( ( \\ SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Pa~e 6 of 85 3.0 PRECAUTIONS AND LIMITATIONS 3.1 PRECAUTIONS A. Steps of this procedure must be performed sequentially, unless specifically stated otherwise. B. Criticality is indicated by a positive stable startup rate (SUR) with no rod motion. Anticipate criticality anytime reactivity changes are being made. Nuclear instrumentation shall be monitored very closely in anticipation of unplanned reactivity rate of change. C. During the hot standby period, observe the source and intermediate range instruments as the Xenon transient progresses to assure that an inadvertent return to criticality does not occur. D. Reactor Engineering should be contacted for guidance on core operating recommendations during unusual power maneuvers such as startup at end of coreJife. [C.8] E. If reactor startup is anticipated prior to reaching the Xenon-free condition, the reactor coolant temperature, rod position, and boron concentration may be used to account for time dependent changes in Xenon concentration. Conditions should be closely monitored to ensure that shutdown margin requirements of 0-SI-NUC-000-038.0 are maintained at all times. If desired, shutdown rods may be withdrawn in accordance with COLR specifications to provide immediate insertion poison for a reactivity excursion. [C.12] F. To preserve the life of 20 AST and 20 ET, power must be removed from the turbine trip Bus A and trip bus B if unit startup is extended. G. During the approach to criticality Operators shall not be distracted by activities such as shift turnover and surveillance testing . [SQ99 0136PER] H. US / SRO Oversight for control rod manipulation shall include: 1. Prior to Rod Movement a. Ensure RPI's within T.S. range (+ or - 12 steps) b. Verify on target with Rx Eng reactivity balance sheet or within limits of Estimated Critical Condition (as applicable) c. Ensure procedural requirements met. d. Ensure no simultaneous reactivity manipulations in progress.


_.

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 7 of85 3.1 PRECAUTIONS (continued) 2. During Rod Movement a. Ensure RO has peer check b. Ensure RO is following procedure c. Ensure RO understands criteria for stopping rod motion (based upon number of steps and/or nuclear instrument response) d. Watch performance of rod manipulation while listening to audible indication of rod step e. Ensure peer checking meets expectations (OPDP-1) f. Re-verify items of initial evaluation (on previous page) g. Monitor plant for expected response (

( ( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 8 of 85 3.2 LIMITATIONS A. Simultaneous reactivity addition by rod withdrawal and dilution is NOT allowed while in the source range. B. If at any point during the approach to criticality, ONE of the two source range detectors shows an unexplained increase in count rate equal to or greater than a factor of 5, or if BOTH source range detectors show an unexplained increase in count rate equal to or greater than a factor of 2, the approach to criticality shall be SUSPENDED IMMEDIATELY (i.e., all rod withdrawals and/or boron dilutions shall be terminated). Further positive reactivity changes shall not be resumed until an evaluation is performed and the Shift Manager authorizes a resumption in the approach to criticality. C. After refueling operations, the NIS indications may be inaccurate until calibration at higher power levels. The NIS calibration procedures will adjust the PRM trip set points to ensure that the excore detectors do not contribute to an overpower condition. Prior to startup, the PRM high range flux trip setpoint will be adjusted from 109 to 60%, with the rod stop (C-2) remaining at 103%. [C.3j - . D. While in Mode 3, maintain the Reactor Coolant System boron concentration in accordan ce with 0-SI-NUC-000-038.0, Shutdown Margin requirements. E. The stepping or tripping of the Control Rod during periods when coolant crud level are high should be kept to a minimum. This will limit the possibility of CRDM mis-stepping due to crud contamination of CRDM latch assemblies.

( '" SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 9 of 85 4.0 STARTUP No. leo' PREREQUISITES Unit I Date ~cIay NOTES 1) Throughout this Instruction where an IF/THEN statement exists, the step should be N/A'd if the condition does not exist. 2) Prerequisites may be completed in any order. 3) Management oversight is required for a Reactor Startup after a non-refueling outage. A Reactor Startup after a refueling outage is a CIPTE. [1 ] ENSURE Instruction to be used is the latest copy of effective version. [2] R~VIEW Precautions and Limitations. ( [3] INDICATE below which instruction this 80 is being entered from:

0-GO-1 (cold shutdown to hot standby)

0-80-6 (30% reactor power to hot standby)

0-80-7 (hot standby to cold shutdown)

0-80-5 (normal power operation) [4] MAINTAIN pressurizer pressure within the normal operating band by use of the pressurizer heaters and spray valves. [5] MAINTAIN pressurizer level greater than or equal to 25%.

SQN UNIT STARTUP FROM HOT STANDBY O-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 10 of 85 4.0 STARTUP No. Iill PREREQUISITES (continued) Unit I NOTE Due to instrument inaccuracies the steam dump or SG atmospheric relief valve setpoint of 84% or 1005 psig may be +/- 1% or +/- 12 psig off. [6] MAINTAIN TAVG stable at 547°F with steam dumps in pressure mode or with SG atmospheric relief valves. [7] MAINTAIN SG levels within the normal operating range using Auxiliary Feedwater. ( [8] [9] ENSURE all reactor coolant pumps are in operation in aceordance with 1,2-S0 -68-2, Reactor Coolant Pumps. [C.12] IF the reactor vessel head has been removed, THEN ENSURE conditional performance of 0-SI-SXX-085-043.0, Rod Drop Time Measurements, has been performed to comply with SR 4.1.3.4.a. \\... [10] REQUEST Periodic Test Coordinate to confirm that the following checklists have been distributed: [10.1] Mode 3 to Mode 2, 1, Surveillance Checklist (NA if previously performed for this startup). [1 0.2] Reactor Trip Breaker Checklist (NA if previously performed for this startup). [11] ENSURE East Valve Vault Room Vent Chute dampers OPEN. (inside door near SPING Room, Ref. PER 03-002446-000). [1 2] NOTIFY MIG to re-scale LR-3-43A and LR-3-98A, Steam Generator Wide Range Level Recorders, to 80% - 90%.

( SQN UNIT STARTUP FROM HOT STANDBY 0*GO*2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 11 of 85 4.0 STARTUP No. /0/ PREREQUISITES (continued) Unit I Date~ ( \\. [13] ENSURE each performer documents their name and initials: Print Name Initials Print Name Initials

>. .t. f.I tt>-

J'.m/" t - END OF TEXT

( SON UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 12 of 85 5.0 STARTUP No. 11821 INSTRUCTIONS Unit I Date Tudry 5.1 Actions to be performed prior to a reactor startup [1] ENSURE Section 4.0. Prerequisites complete. NOTE Steps 5.1[2] through 5.1[11] may be performed in any order. [2] [3] INTIATE Appendix B, * Mode 3 to Mode 2,1 Review And Approval while continuing with this instruction. OBTAIN assistance from Systems Engineering to complete Appendix B steps associated with Pressurizer Spray line bypass valves. ( NOTE Steps for MFPT startup may be performed in parallel with other activities. The MFPT trip busses shall be energized prior to entering Mode 2 (LCO 3.3.2.1 or 3.3.2) except as allowed by LCO 3.0.4. [C.1] [4] INITIATE applicable section(s) of 1, 2-S0-2/3-1 to prepare at least one MFP for startup. while continuing with this instruction. (N/A if no MFPT available) [5] ENSURE TDAFW LCVs are in NORMAL. 2fK AfIdP 1st IV

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 13 of 85 Actions to be performed prior to a reactor startup (continued) 5.1 STARTUP No. /at::t U n it~/<--_ Date~ CAUTION Rapid changes in pressurizer enclosure temperatu re may result in pressurizer safety valve simmer. [6] IF lower compartment coolers are not in service. THEN [6.1] ALIGN lower compartment coolers to maintain pressurizer enclosure temperature less than 110°F in accordance with 0-SO-30-5. ( [7] [6.2] MONITOR Pressurizer enclosure temperature _ using Plant Computer pt. T1001A. IF control rod drive coolers are not in service, THEN [7.1 ] ALIGN control rod drive coolers to maintain shroud enclosure temperature less than 164°F in accordance with 0-SO-30-6. [7.2] MONITOR Reactor Cavity Air temperature using Plant Computer pt. T1014A. NOTE New analysis is not required for this startup. Routine analysis is sufficient unless there is reason to suspect chemistry has been changed. [8] NOTIFY Chemistry Supervisor that mode change from 3 to 2 requires sampling in accordance with 0-SI-CEM-000-050.0. 0-SI-CEM-030-407.2, and 0-SI-CEM-030-415.0 requirements.

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO*2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 14 of 85 Actions to be performed prior to a reactor startup (continued) 5.1 STARTUP No. /4c:f Unit ~/,---_ Date 7<<IA.{ ( NOTE To preserve the life of 20 AST and 20 ET, power must be removed from turbine trip bus A and trip bus B if unit startup is extended. [9] ENERGIZE main turbine trip buses by CLOSING the following breakers (NA breakers not applicable): UNIT TRAIN BREAKER 250V DC POSITION INITIALS RIle buR TRAIN A 1-BKRD-47-KA/516 BAIT Bd 1 CLOSED 1st CV 1 i lK IfW? l- 1-BKRD-47-KB/516

TRAIN B BAITBd 2 CLOSED 1st CV llh:- At",; TRAIN A 2-BKRD-47-KA/519 BAIT Bd 1 CLOSED 1st CV 2 ,;,nr -* TRAIN B 2-BKRD-47-KB/519 BAITBd 2 CLOSED 1st NOTE Step 5.1[10] may be marked N/A if not required. [10] PERFORM 0-PI-OPS-047-723.0, 20/AST, 20/ET, 20-1/0PC, and 20-210 PC Operability Verification (N/A if not performed).

( " SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 15 of 85 Actions to be performed prior to a reactor startup (con ti nued) 5.1 STARTUP No. IMI Unit 1 Date~ ( CAUTIO N Operation of the Hic pumps without the turbine being reset will result in overheating of the EHC fluid and pu mps. NOTE Startup of EHC and turbine reset may be postponed until later in startup, (N/A if postponed) [11] ENSURE EHC system in service in accordance with 1,2-50 -47-2 (NA if previously performed), [12] IF 1'\\0 MFPT is ready for start up per 1,2-80-2/3-1 , THEN GO TO Section 5,1[18]. [1 3J ENSURE MFPT designated for startup has been tested and ready for start up per 1, 2-80-2/3-1 PRIOR to proceeding with the next step, 'll~ J sa<< /1Xf&c+---- Initials Datr 61n le-£ Time

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO*2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 16 of 85 5.1 STARTUP No. / tA:I Unit I Actions to be performed prior to a reactor startup (continued) Date 7 m411:\\I ( NOTES 1) Steps for MFPT startup may be performed in parallel with other activities. The MFPT trip busses shall be energized prior to entering Mode 2 (LCO 3.3.2.1 or 3.3.2) except as allowed by LCO 3.0.4. [C.1] 2) Power is placed on only ONE MFPT trip bus in Step 5.1[14] to prevent inadvertent AFWP start. [14] ENSURE power restored to ONLY ONE of MFPT trip busses on the applicable unit: (N/A breakers not applicable.) [C.1] PUMP ELECTRICAL BREAKER BREAKER NO. BOARD INITIALS POSITION 250v DC MId Zj/tr MFPT 1A 1-BKRD-46-KN523 Battery Bd I CLOSED 1st CV 250v DC ~ 'P MFPT 1B 1-BKRD-46-KN524 Battery Bd I CLOSED st CV 250v DC At/"

,-

MFPT 2A 2-BKRD-46-KB/523 Battery Bd 2 CLOSED 1s CV 250v DC 'b MFPT 2B 2-BKRD-46-KB/524 Battery Bd 2 CLOSED H t CV

( --_._-- - SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 17 of 85 5.1 STARTUP No. 1(;(;)( Unit I Date~ Actions to be performed prior to a reactor startup (continued) CAUTION Failure to rese t a MFPT prior to energizing the remaining MFPT trip buss will initiate an ESF actuation. NOTE If 51 signal or Hi/Hi steam generator level has occurred, Reactor Trip Breakers will have to be cycled. [15] RESET MFPT energized in step 5.1[14] above. 1st ~odtrx. Time 7rley Date ( CV NOTE IF the remaining NON-running MFPT is not available, THEN N/A step 5.1[16] and 5.1[17] [16] RESTORE power to remaining MFPT Trip Bus on applicable unit. (N/A breakers not applicable) PUMP BREAKER NO. ELECTRICAL BREAKER INITIALS BOARD POSITION 250v DC Battery AJ{# '9> MFPT 1A 1-BKRD-46-KA/523 Bd I CLOSED st CV 250v DC Battery /'4' -II/f(£ MFPT 1B 1-BKRD-46-KA/524 Bd I CLOSED 1st CV 250v DC Battery /1/11 '9 MFPT 2A 2-BKRD-46-KB/523 Bd 2 CLOSED 1~t CfJ 250v DC Battery MFPT 2B 2-BKRD-46-KB/524 Bd 2 CLOSED 1st OV

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 18 of 85 STARTUP No. /(D I Unit I Date 7dJ~ 5.1 Actions to be performed prior to a reactor startup (continued) [17] RESET MFPT energized in step 5.1 [16] above. _--Ji'M:'----__ 1st CV &A1ti!q Time 00In Time 'fJ~7 Date ( [18] SELECT one source range channel and one intermediate range channel with the highest readings to record on NR 45. [19] ENSURE audio count rate channel is in operation and selected for source range channel with highest reading. [C.1 1] [20] ENSURE all reactor first out alarms reset. NOTE Refer to 1-PI-OPS-000-021.1 (Unit 1) or 2-PI-OPS-000-023.1 (Unit 2) for updating the Plant Computer. [21] IF ICS is available. THEN ENSURE Plant Computer is reset and updating (NA if previously performed). [C.5] NOTE Closing of the RTB's for performance of 0-SI-OPS-085-01 1.0 (SR 4.1.3.3) is addressed in Licensing and NRC TelephoneNisit Report RIMs # S10 960521 800. [22] IF 0-SI-OPS-085-011.0 is out-of-frequency, THEN [22.1] CLOSE RTB's provided Group Demand counters have no known deficiencies. Q""'" [22.2] PERFORM 0-SI-OPS-085-011.0 (NA if above step cannot be performed).

( saN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 19 of 85 Actions to be periormed prior to a reactor startup (continued) [23] IF control rods were withdrawn 5 steps to prevent thermal lockup during RCS heatup, THEN INSERT control rods in accordance with 0-SO-85-1. 5.1 STARTUP No. /Ql)1 Unit I Date~ [26.1] ( [24] ENSURE Rod Bank Update completed by performing the following: [24.1] DEPRESS NSSS and BOP button on ICS main screen. [24.2] DEPRESS ROD BANK UPDATE Button AND ENSURE all bank positions are zero. [24.3] _ DEPRESS F3 to save these rod bank positions. [25] VERIFY Rod Bank Update status by performing the following: [25.1] DEPRESS NSSS and BOP button on ICS main screen. [25.2] DEPRESS ROD INSERTION LIMIT DISPLAY Button. [25.3] VERIFY Rod Bank Update Status indicates "UPDATED" in green letters. NOTE TI-28 defines fully withdrawn position. [26] IF shutdown rods are inserted. THEN PERFORM the following: VERIFY sufficient shutdown reactivity exists USING 0-SI-NUC-000-038.0, Shutdown Margin. [26.2] WITHDRAW Shutdown Rods to fully withdrawn position in accordance with 0-SO-85-1. 1st CV

FROM : SEQUCYAH OPERATOR TRAI NI NG PHONE NO. 423 843 4339 Hpr-, 04 2007 02 : 00PM P3 ( .r--, saN UnitO UNIT STARTUP FROM HOT STANDBY 0-GO-2 TO REACTOR CRITICAL Rev. 0026 PaCle 26 of 85 I CAUTION ~) NOT exceed a steady startup rate of +1 DPM. ~ NOTE l~l1e unit enters Mode 2 when the control banks are first withdrawn. 5.2 STARTUP No. /()c) I Unit' Reactor Startup after a refueling outage (continued) Date~ III [17] INITIATE a reactor startup by performing the following: [17.1] . RECORD both source range readings for ICRR base counts. N-31 .2~ CPS N-32 /1 CPS Lk Initials ( [17.2] RECORD intermediate range readings. N-35/..3X(~~10 N-36Plxt,*f, -2IIIL- Initials [1 7,3J CALCULATE initial source range count doubling value USING Appendix C. MODE 2 [17.4] INITIATE withdrawal of control banks in accordance with o-SO-85-1 to first stop'point: 128 STEPS CONTROL BANK A ___----I .J [17.5] ENSURE Mode 2 entry is logged (log entry may be performed out of sequence late-) , o

(

  • '

SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Pa!le 26 of 85 5.2 STARTUP No. /()p{ Unit / , Reactor Startup after a refueling outage (continued) CAUTION Do NOT exceed a steady startup rate of +1 DPM. NOTE The unit enters Mode 2 when the control banks are first withdrawn. [17] INITIATE a reactor startup by performing the following : [17.1] RECORD both source range readings for ICRR base counts. N-31{.27~CP5 N-32/$oc)CP5 .?/Ie: Initials ( [17.2] RECORD intermediate range readings. N -35 t 3k ~~fo N-36 t4",rfo [17.3] CALCULATE initial source range count doubling value USING Append ix C. MODE 2 [17.4] INITIATE withdrawal of control banks in accordance with 0-50-85-1 to first stop point: &tr Initials CONTROL BANK A 128 STEPS [17.5] ENSURE Mode 2 entry is logged (log entry may be performed out of sequence later), o

SQN UNIT STARTUP FROM HOT STANDBY 0*GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 27 of 85 Reactor Startup after a refueling outage (continued) Date~ I Unit_-s-_ STARTUP No. IIXJ! 5.2 [18] WHEN control bank A is at 128 steps, THEN PERFORM the following: [18.1] [1 8.2] [18.3] STOP rod withdrawal. WAIT for approximately two minutes. NOTIFY Rx Engineering to perform ICRR calculation in accordance with 0-RT-NUC-000-003.0. [C.11] CAUTION Lowest loop T*avg must be verified greater than or equal to 541°F using 0*SI-SXX*068-127.0 within 15 minutes prior to achieving criticality. ( NOTES 1) Approximately five to seven count doublings are expected to result in criticality. However, criticality should be anticipated at any time. 2) Proper bank overlap must be verified using 0-80-85-1 as each successive rod bank is withdrawn. [19] WHEN concurrence obtained from Rx Engineering, THEN INITIATE rod withdrawal to first count doubling (determined in App. C) USING 0-80-85-1.

\\.. SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Pace 28 of 85 Reactor Startup after a refuel ing outage (continued) Date~ I Unit_--L.._ STARTUP No. /<<';1 5.2 NOTE Steps 5.2[20] and 5.2[21] may be repeated as necessary if rod motion is stopped prior to reaching doubling value. [20] WHEN any of the following conditions are met:

Source range count rate is approximately equal to first doubling value determined in Appendix C OR

Control bank being withdrawn reaches 128 steps (requires verifying overlap in 0-SO-85-1 ) OR (

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. [21] IF rod motion was stopped prior to reaching doubling range AND Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal to first count doubling USING 0-80-85-1. [22] IF source range count rate has reached or exceeded first doubling, THEN PERFORM the following: [22.1] ENSURE rod motion STOPPED. [22.2] WAIT approximately 2-3 minutes to allow count rate to rise. nrti

[22.3] NOTIFY Rx Engineering to perform ICRR calculations in accordance with O-RT-NUC-000-003.0. [C.11] [22.4] DETERMINE new count doubling range USING Appendix C.

SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 29 of 85 Date~ I Unit_.L-_ STARTUP No. Ity;( , Reactor Startup after a refueling outage (continued) 5.2 [23] IF IGRR plot indicates criticality will fall outside +/- 1000 pcm EGGtermination band, THEN [23.1 ] NOTIFY SM and Duty Plant Manager. [23.2] EVALUATE if EGG should be recalculated prior to continuing startup. [23.3] IF startup must be aborted, THEN ~ PERFORM Appendix D, Actions if Reactor Startup Must ' f-1 Be Aborted. '-J ( [24] WI:IEN concurrence obtained from Rx Engineering, THEN INITIATE rod withdrawal to second doubling range (determined in App. G) USING 0-SO-85-1. NOTE Steps 5.2[25] and 5.2[26] may be repeated as necessary if rod motion is stopped prior to reaching doubling range. [25] WHEN any of the following conditions are met:

Source range count rate reaches or exceeds second doubling range determined in Appendix G OR

Control bank being withdrawn reaches 128 steps (requires verifying overlap in 0-SO-85-1) OR

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion.

c SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 30 of 85 I Unit_4-_ STARTUP No. / cal 5.2 Reactor Startup after a refueling outage (continued) [26] IF rod motion was stopped prior to reaching doubling range AND Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal to second doubling range USING 0-SO-85-1. [27] IF source range count rate has reached or exceeded second doubling range, THEN PERFORM the following: [27.1] ENSURE rod motion STOPPED. WE

c [27.2] WAIT approximately 2-3 minutes _ to allow count rate to rise. [27.3] NOTIFY Rx Engineering to perform ICRR calculations in accordance with 0-RT-NUC-000-003.0. [C.11] [27.4] DETERMINE new count doubling range USING Appendix C. [28] IF ICRR plot indicates criticality will fall outside +/- 1000 pcm ECC termination band, THEN [28.1] NOTIFY SM and Duty Plant Manager. [28.2] EVALUATE if ECC should be recalculated prior to continuing startup. [28.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. [29] IF ICRR plot trend indicates acceptable ECC, THEN INITIATE rod withdrawal to third doubling range (determined in App. C) USING 0-SO-85-1. \\..

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 31 of 85 5.2 STARTUP No. IfX;JI Unit I Reactor Startup after a refueling outage (continued) NOTE Steps 5.2[30] and 5.2[31] may be repeated as necessary if rod motion is stopped prior to reaching doubling range. [30] WHEN any of the following conditions are met:

Source range count rate reaches or exceeds third doubling range determined in Appendix C OR

Control bank being withdrawn reaches 128 steps (requires verifying overlap in 0-SO-85-1) OR ( [31]

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. IF rod motion was stopped prior to reaching doubling range AND Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal to third doubling range USING 0-SO-85-1 . [32] IF source range count rate has reached or exceeded third doubling range, THEN PERFORM the following: [32.1] [32.2] [32.3] [32.4] ENSURE rod motion STOPPED. WAIT approximately 2-3 minutes to allow count rate to rise. NOTIFY Rx Engineering to perform le RR calculations in accordance with 0-RT-NUC-000-003.0. [C.11] DETERMINE new count doubling range USING Appendix C.

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 32 of 85 5.2 STARTUP No. --I..Od.- Unit I* Reactor Startup after a refueling outage (continued) [33] IF ICRR plot indicates criticality will fall outside +/- 1000 pcm ECC termination band, THEN [33.1] NOTIFY SM and Duty Plant Manager. [33.2] EVALUATE if ECC should be recalculated prior to continuing startup. ( [33.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must if' Be Aborted. r:! [34] IF ICRR plot trend indicates acceptable ECC, THEN INITIATE rod withdrawal USING 0-SO-85-1 to fourth doubling range (App. C) or criticality. NOTE Steps 5.2[35] through 5.2[37] may be repeated as necessary if rod motion is stopped prior to reaching doubling range or criticality. [35] WHEN any of the following conditions are mel:

Source range count rate reaches or exceeds fourth doubling range determined in Appendix C OR

Control bank being withdrawn reaches 128 steps (requires verifying overlap in 0-SO-85-1 ) OR

Bank D rods reach fully withdrawn position OR

. Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion.

( - - - - - - - SON UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 33 of 85 ( 5.2 STARTUP No.~ Unit I Reactor Startup after a refueling outage (continued) [36] IF reactor is critical, THEN GO TO Step 5.2[59] (N/A Steps 5.2[37] through 5.2[58]). [37] IF ALL of the following conditions are met:

rod motion was stopped prior to reaching doubling range or criticality

Bank D rods are below fully withdrawn position

Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal USING 0-SO-85-1 to fourth doubling range or criticality (whichever comes first). [38] IF source range count rate has reached or exceeded fourth doubling range, THEN PERFORM the following: [38.1] ENSURE rod motion STOPPED. [38.2] WAIT approximately 2-3 minutes to allow count rate to rise. Date/(;""; ~D 0 0 [38.3] NOTIFY Rx Engineering to perform ICRR calculations in accordance with 0-RT-NUC-000-003.0. [C.11] [38.4] DETERMINE new count doubling range USING Appendix C. [39] IF reactor is subcritical with Bank D rods at fully withdrawn position, THEN ~ PERFORM Appendix E, Actions if Reactor is Subcritical with ~ 0 Rods Fully Withdrawn.

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 34 of 85 Reactor Startup after a refue ling outage (continued) 5.2 STARTUP No. /0l?I Unit I Date~ ( [40] IF ICRR plot indicates criticality will fall outside +/- 1000 pcm ECC termination band, THEN [40.1] NOTIFY SM and Duty Plant Manager. [40.2] EVALUATE if ECC should be recalculated prior to continuing startup. [40.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. [41] IF I.9RR plot trend indicates acceptable ECC, THEN INITIATE rod withdrawal USING 0-SO-85-1 to fifth doubling range (App. C) or criticality. NOTE Steps 5.2[42] through 5.2[44] may be repeated as necessary if rod motion is stopped prior to reaching doubling range or criticality. [42] WHEN any of the following conditions are met:

Source range count rate reaches or exceeds fifth doubling range determined in Appendix C OR

Bank D rods reach fully withdrawn position OR

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. [43] IF reactor is critical, THEN GO TO Step 5.2[59] (N/A Steps 5.2[44] through 5.2[58]).

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Pace 35 of 85 ( 5.2 STARTUP No. / cht Unit I Reactor Startup after a refueling outage (continued) [44] IF ALL of the following conditions are met:

rod motion was stopped prior to reaching doubling range or criticality

Bank D rods are below fully withdrawn position

Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal USING 0-SO-85-1 to fifth doubling range or criticality (whichever comes first). [45] IF source range count rate has reached or exceeded fifth doubling range, THEN PERFORM the following: [45.1] ENSURE rod motion STOPPED. [45.2] WAIT approximately 2-3 minutes to allow count rate to rise. Date /do"7 [45.3] NOTIFY Rx Engineering to perform leRR calculations in accordance with 0-RT-NUC-000-003.0. [C.11] [45.4] DETERMINE new count doubling range USING Appendix C. [46] IF reactor is subcritical with Bank D rods at fully withdrawn position, THEN PERFORM Appendi x E, Actions if Reactor is Subcritical with Rods Fully Withdrawn.

SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 36 of 85 ( 5.2 STARTUP No. L@_ Unit I Reactor Startup after a refueling outage (continued) [47] IF IGRR plot indicates criticality will fall outside +/- 1000 pcm EGG termination band, THEN [47.1] NOTIFY SM and Duty Plant Manager. [47.2] EVALUATE if EGG should be recalculated prior to continuing startup. [47.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. Date4 NOTE Steps 5.2[49] through 5.2[51] may be repeated as necessary if rod motion is stopped prior to reaching doubling range or criticality. ( [48] IF IGRR plot trend indicates acceptable EGG, THEN INITIATE rod withdrawal USING 0-SO-85-1 to sixth doubling range (App. C) or criticality. [49] WHEN any of the following conditions are met:

Source range count rate reaches or exceeds sixth doubling range determined in Appendix C OR

Bank D rods reach fully withdrawn position OR

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. [50] IF reactor is critical, THEN GO TO Step 5.2[59] (N/A Steps 5.2[51]through 5.2[58]).

SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 37 of 85 ( 5.2 STARTUP No. / t?i'J1 Unit I Reactor Startup after a refueling outage (continued) [51) IF ALL of the following conditions are met:

rod motion was stopped prior to reaching doubling range or criticality

Bank D rods are below fully withdrawn position

Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal USING 0-SO-85-1 to sixth doubling range or criticality (whichever comes first). [52) IF source range count rate has reached or exceeded sixth doubling range, THEN PERFORM the following: [52.1] ENSURE rod motion STOPPED. [52.2] WAIT approximately 2-3 minutes to allow count rate to rise. Date /dclai [52.3] NOTIFY Rx Engineering to perform ICRR calculations in accordance with 0-RT-NUC-000-003.0. [C.11) [52.4) DETERMINE new count doubling range USING Appendix C. [53) IF reactor is subcritical with Bank D rods at fully withdrawn position, THEN PERFORM Appendix E, Actions if Reactor is Subcritical with Rods Fully Withdrawn.

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Pace 38 of 85 5.2 STARTUP No. [(J()( Unit I Reactor Startup after a refueling outage (co ntinued) [54] IF IGRR plot indicates criticality will fall outside +/- 1000 pcm EGG termination band, THEN [54.1] NOTIFY SM and Duty Plant Manager. [54.2] EVALUATE if EGG should be recalculated prior to continuing startup. [54.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. [55] IF IGRR plot trend indicates acceptable EGG, THEN INITIATE rod withdrawal USING 0-SO-85-1 to seventh doubling range (App. C) or criticality. o ( NOTE Steps 5.2[56] through 5.2[58] may be repeated as necessary if rod motion is stopped prior to reaching doubling range or criticality. [56] WHEN any of the following conditions are met:

Source range count rate reaches or exceeds seventh doubling range determined in Appendix G OR

Bank D rods reach fully withdrawn position OR

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. [57] IF reactor is critical, THEN GO TO Step 5.2[59] (N/A Step 5.2[58]). DODD

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 39 of 85 STARTUP No. _ Unit _ Date _ 5.2 Reactor Startup after a refuel ing outage (continued) [58] IF ALL of the following conditions are met:

rod motion was stopped prior to reaching doubling range or criticality

Bank D rods are below fully withdrawn position

Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal USING 0-SO-85-1 to seventh doubling range or criticality (whichever comes first). 0 0 0 0 [59] IF any of the following conditions exist:

- critical conditions cannot be achieved within the +/-1000 pcm allowable limits OR

critical conditions cannot be achieved above rod insertion limit OR

reactor startup must be aborted for other reasons, THEN PERFORM the following to abort reactor startup: [C.11] [59.1] STOP rod withdrawal. [59.2] INITIATE insertion of control banks. [59.3] PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. [59.4] DO NOT CONTINUE this section. o

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 40 of 85 5.2 STARTUP No. Unit _ Reactor Startup after a refueling outage (continued) Date _ c.... [60] IF reactor is subcritical with Bank D rods at fully withdrawn position, THEN PERFORM Appendix E, Actions if Reactor is Subcritical with Rods Fully Withdrawn. 0 [61] IF reactor is critical with SUR less than 0.3 DPM AND intermediate range NIS is less than P-6 (1 X 10.4 %), THEN PERFORM the following: [61.1] IF Bank D control rods are BELOW - fully withdrawn position, THEN OPERATE control rods to establish a positive SUR of approximately 0.3 DPM. [61 .2] IF Bank 0 rods have reached fully withdrawn position AND Rx Engineering concurs with RCS dilution, THEN PERFORM RCS dilution (as recommended by Rx Eng) to establish positive SUR of approx. 0.3 DPM USING 0-SO-62-7.

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 41 of 85 STARTUP No. _ Unit _ Date _ 5.2 Reactor Startup after a refueling outage (continued) IStart of Critical Step(s) NOTES 1) Blocking the SRM reactor trip with [HS-92-50011 and [HS-92-50021 will disable the detector outputs and remove the audio count rate signal. 2) Step 5.2[62) may be performed at time of criticalit¥. if required. Source range reactor trip must be BLOCKED before trip setpoints of 10 cps. [62) WHEN annunciator XA-55-4A, window 0-2 P-6 INTERMEDIATE RANGE PERMISSIVE is LIT, THEN [C.2) [62.1) RECORD both source range readings. N-31 CPS N-32, CPS Initials [62.2) RECORD both intermediate range readings. N-35 %RTP N-36 %RTP Initials [62.3) VERIFY a minimum of one IRM channel greater than or equal to 1 X 10 -4 % RTP. o [62.4] BLOCK source range reactor trip by momentarily placing [HS-92-50011 and [HS-92-50021SRM TRIP RESET-BLOCK P-6 handswitches to BLOCK. Initials Date Time

(.. SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 42 of 85 STARTUP No. _ Unit _ Date _ 5.2 Reactor Startup after a refueling outage (continued) [62.5] VERIFY annunciator XA-55-4A, window C-1 SOURCE RANGE TRAINS A & B TRIP BLOCK is LIT. IEnd of Critica l Step(s) [62.6] SELECT NR 45to record one intermediate range channel and one power range channel. [62.7] ADJUST NR 45 chart speed as desired. (N/A is no change needed.) [63] ENSURE PA announcement made to notify plant personnel when the reactor is critical. NOTE o o o ( When T-avg is less than 551°F and Tavg - Tref deviation alarm is lit, SR 4.1.1.4.b requires verifying lowest T-avg greater than or equal to 541°F at least once per 30 minutes. [64] IF Tavg - Tref deviation alarm [M-5A window C-6] is LIT AND T-avg is less than 551°F, THEN PERFORM 0-SI-SXX-068-127.0 to satisfy SR 4.1.1.4.b, Minimum Temperature For Criticality.

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 43 of 85 STARTUP No. _ Unit _ Date _ 5.2 Reactor Startup after a refueling outage (continued) [65) RAISE reactor power to approximately 1 X 10-3%: [65.1) IF Bank 0 control rods are BELOW fully withdrawn position, THEN OPERATE control rods to establish a positive SUR of approximately 0.5 OPM (not to exceed 1 OPM). [65.2) IF Bank 0 rods have reached fully withdrawn position AND Rx Engineering concurs with RCS dilution, THEN PERFORM RCS dilution (as recommended by Rx Eng) to establish positive SUR of approx. 0.5 DPM USING 0-SO-62-7. [65.3] WHEN intermediate range Nls indicate approximately 1 X 10.3%, THEN PERFORM the following: [65.3.1) STABILIZE reactor power using control rods. [65.3.2) RECORD critical data indicated below. Power Level: Rod Position: N-35_ _ %RTP N-36_ _ %RTP RCS Boron concentration Bank Step 1 Initials 2 Date 3 ppm 4 Time [66J MAINTAIN reactor power stable with control banks above low insertion limit USING rod movement or boration/dilution to compensate for Xenon. o

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Pane 44 of 85 STARTUP No. _ Unit _ Date _ 5.2 Reactor Startup after a refueling outage (continued) [67] IF start up is to continue with one or both MFPTs available, THEN [67.1] ENSURE Steps 5.1 [13] through 5.1[15] have been completed for applicable pump(s). [67.2] VERIFY other applicable actions Section 5.2 completed or initiated . [67.3] GO TO 0-GO-3, Power Ascension From Reactor Critical to Less Than 5% Reactor Power. [68] IF start up is to continue with NO MFPT available, THEN [68.1] MARK Steps 5.1[13] through 5.1[17] as 'ON/A". [68.2] VERIFY other applicable actions in Section 5.2 completed or initiated. [68.3] GO TO 0-GO-3 , Power Ascension From Reactor Critical to Less Than 5% Reactor Power. [69] IF startup is to be discontinued, THEN GO TO 0-GO-6, Power Reduction From 30% Reactor Power to Hot Standby. END OF TEXT

c SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 45 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage [1] VERIFY applicable actions in Section 5.1 completed or initiated. NOTE Steps 5.3[3] through 5.3[8] may be performed out of sequence. [2] IF any MFPT trip buss is NOT energized, THEN [2.1] ENSURE requirements of LCO 3.0.4 are satisfied. [2.2] NOTIFY Unit SRO that LCO 3.3.2.1 (3.3.2) action 20 will apply when Mode 2 is entered . ( [3] ENSURE Appendix B, Mode 3 to Mode 2, 1 Review and Approval has been completed to ensure all restraints to Mode 2, 1 entry have been resolved and approvals for mode change granted. SM [4] BLOCK Source Range High Flux At Shutdown alarm: [4.1] PLACE BOTH HI FLUX AT SHUTDOWN switches on M-13 to the BLOCK position. [4.2] VERIFY annunciator XA-55-4B window C-1, SOURCE RANGE HIGH SHUTDOWN FLUX ALARM is L1T.[C.2]. CLOCK o [5] VERIFY greater than or equal to 0.5 cps on the highest reading SR instrument. o

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 46 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) NOTE The following count rates may be used as a reference during the approach to criticality. [6] RECORD SR count rates from two of the following: [C.2) (N/A instruments not used) XI-92-5001A (N31) cps XI-92-5002A (N32) cps OR XI-92-5001B XI-92-5002B (N31) (N32) _ _ _ cps _ _ _ _cps Time Date ( ( [7) IF conditions exist which could cause Power Range NIS indications to be non-conservative, THEN ENSURE Power Range high flux trip setpoints reduced to 60% in accordance with the following: [C.3)

1,2-SI-ICC-092-N41 .1 0

1,2-SI-ICC-092-N42.2 0

1,2-SI-ICC-092-N43.3 0

1,2-SI-ICC-092-N44.4 0 Instrument Maintenance Date Time

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 47 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [8) VERIFY the estimated critical position calculated in accordance with 0-81-NUC-000-001.0, Estimated Critical Conditions. Estimated critical position: Assumed boron concentration: steps on bank ppm Initials 8TA Time Time Date Date ( [9] VERIFY Steps 5.3[1] through 5.3[8) completed. [10] IF estimated critical boron concentration does NOT approximately equal actual boron concentration, THEN [10.1) DETERMINE the appropriate boration/dilution requirements to achieve criticality within acceptable limits. D [10.2) DILUTE/BORATE in accordance with 0-80-62-7 to the estimated critical boron concentration. [C.12] D [10.3) OPERATE pressurizer heaters/spray as necessary to equalize boron concentration (within 50 ppm) between reactor coolant loops and the pressurizer. [C.12] D [10.4] WHEN sufficient mixing has occurred, THEN OBTAIN a new boron sample. D [10.5] ENSURE actual boron concentration is approximately equal to the estimated critical boron concentration.

( saN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 48 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) NOTE Termination limits are associated with +/- 750 pcm tolerance band. These values are within minimum and maximum rod positions corresponding to Tech Spec limit of +/- 1000 pcm (Minimum and Maximum Allowable Limits). Termination limits shall be used by Reactor Engineering and Operations to determine whether approach to criticality should be terminated and a new ECC calculated . ECC must be terminated if Minimum or Maximum Allowable Limits (corresponding to Tech Spec limit of +/- 1000 pcm) are approached. [11] RECORD upper and lower rod position limits corresponding to +/- 750 pcm Termination Band as determined by 0-SI-NUC-000-001.0. Estimated Critical Conditions. ( Upper termination rod position Lower termination rod position steps on bank steps on bank Initials Time Date [12] RECORD minimum and maximum rod positions corresponding to +/- 1000 pcm ALLOWAB LE LIMITS (Tech Spec Limit) determined by 0-SI-NUC-000-001.0, Estimated Critical Conditions. [C.11] Minimum allowable rod position Maximum allowable rod position steps on bank steps on bank Initials Time Date ( [13] VERIFY all shutdown rods are fully withdrawn in accordance with 0-SI-OPS-000-004.0. Surveillence Requirements Performed on Increased Frequency with no Specific Frequency, within 15 minutes prior to withdrawing control rods. Time Date

( SON UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 49 of 85 STARTUP No. _ Unit _ Date _---'__ 5.3 Reactor Startup after a non-refue ling outage (conti nued) NOTE SR 4.1.1.4.a requires verifying lowest T-avg greater than or equal to 541°F within 15 minutes prior to achieving criticality. [14] IF O-SI-SXX-068-127.0 is NOT in progress, THEN INITIATE applicable sections of O-SI-SXX-068-127.0 to satisfy SR 4.1.1.4.a., Minimum Temperature For Criticality. [15] NOTIFY onsite personnel of reactor startup over PIA system. 0 CAUTION Avoid operations that could produce sudden changes of temperature or unplanned boron concentration changes during approach to criticality or low power. NOTES 1) Nuclear instrumentation shall be monitored very closely for indications of unplanned reactivity rate of change. [C.11] 2) Activities that can distract operators and supervisors involved with reactor startup, such as shift turnover and surveillance testing during approach to criticality, SHALL BE avoided. [C.12] 3) ICS points N0031A, N0032A, N0035A, and N0036A may be used as an aid for monitoring NIS indications. [16] MONITOR nuclear instruments during approach to criticality: [16.1] MONITOR source range and intermediate range NIS to identify potential reactivity anomalies. [C.11] [16.2] IF desired to place NR-45 recorder in fast speed, THEN ADJUST chart speed to high. o

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 50 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) CAUTION Do NOT exceed a steady startup rate of +1 DPM. NOTE The unit enters Mode 2 when the control banks are first withdrawn. [17] INITIATE a reactor startup by performing the following: [17.1] RECORD both source range readings for leRR base counts. N-31__CPS N-32,__CPS Initials [17.2] RECORD intermediate range readings. N-35 % N-36 % Initials [17.3] CALCULATE initial source range count doubling value USING Appendix C. MODE2 [17.4] INITIATE withdrawal of control banks in accordance with 0-SO-85-1 to first stop point: CONTROL BANK A 128 STEPS ( [17.5] ENSURE Mode 2 entry is logged (log entry may be performed out of sequence later). o

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Pane 51 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [18] WHEN control bank A is at 128 steps, THEN. PERFORM the following: [18.1] STOP rod withdrawal. [18.2] WAIT for approximately two minutes. [18.3] NOTIFY Rx Engineering to perform ICRR calculation in accordance with 0-81-NUC-000-001.0. [C.11] CAUTION Lowest loop T-avg must be verified greater than or equal to 541 °F us ing 0-SI-SXX-068-127.0 within 15 minutes prior to achieving criticality. NOTES 1) Approximately five to seven count doublings are expected to result in criticality. However, criticality should be anticipated at any time. 2) Proper bank overlap must be verified using 0-80-85-1 as each successive rod bank is withdrawn. [19] WHEN concurrence obtained from Rx Engineering, THEN INITIATE rod withdrawal to first count doubling (determined in App. C) USING 0-80-85-1. o

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Pace 52 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reacto r Startup after a non-refueling outage (continued) NOTE Steps 5.3[20) and 5.3[21) may be repeated as necessary if rod motion is stopped prior to reaching doubling value. [20] WHEN any of the following conditions are met:

Source range count rate is approximately equal to first doubling value determined in Appendix C OR

Control bank being withdrawn reaches 128 steps (requires verifying overlap in 0-SO-85-1) OR

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. [21) IF rod motion was stopped prior to reaching doubling range AND Unit Supervisor concu rrence is obtained to resume, THEN RESUME rod withdrawal to first count doubling USING 0-SO-85-1. [22] IF source range count rate has reached or exceeded first doubling, THEN PERFORM the following: [22.1] ENSURE rod motion STOPPED. [22.2] WAIT approximately 2-3 minutes to allow count rate to rise. DODD DO DD ( [22.3) NOTIFY Rx Engineering to perform ICRR calculations in accordance with 0-SI-NUC-000-001 .0. [C.1 1] 0 [22.4) DETERMINE new count doubling range USING Appendix C.

( SQN UNIT STARTUP FROM HOT STANDBY O-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 53 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [23) IF ICRR plot indicates criticality will fall outside +/- 750 pcm ECC termination band, THEN [23.1) NOTIFY SM and Duty Plant Manager. [23.2) EVALUATE if ECC should be recalculated prior to continuing startup. [23.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. 0 ( [24) WHEN concurrence obtained from Rx Engineering, THE;.N INITIATE rod withdrawal to second doubling range (determined in App. C) USING 0-SO-85-1. NOTE Steps 5.3[25) and 5.3[26] may be repeated as necessary if rod motion is stopped prior to reaching doubling range. [25) WHEN any of the following conditions are met:

Source range count rate reaches or exceeds second doubling range determined in Appendix C OR

Control bank being withdrawn reaches 128 steps (requires verifying overlap in 0-SO-85-1) OR

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. o 000 0

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Page 54 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [26] IF rod motion was stopped prior to reaching doubling range AND Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal to second doubling range USING 0-SO-85-1. [27] IF source range count rate has reached or exceeded second doubling range, THEN PERFORM the following: [27.1] ENSURE rod motion STOPPED. [27.2] WAIT approximately 2-3 minutes to allow count rate to rise. 0000 [27.3] NOTIFY Rx Engineering to perform ICRR calculations in accordance with 0-SI-NUC-000-001.0. [C.11] 0 [27.4] DETERMINE new count doubling range USING Appendix G. [28] IF IGRR plot indicates criticality will fall outside +/- 750 pcm EGG termination band, THEN [28.1] NOTIFY SM and Duty Plant Manager. [28.2] EVALUATE if EGG should be recalculated prior to continuing startup. [28.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. 0 [29] IF IGRR plot trend indicates acceptable EGG, THEN INITIATE rod withdrawal to third doubling range (determined in App. G) USING 0-SO-85-1. o

( -. SON UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 - TO REACTOR CRITICAL Rev. 0026 Page 55 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) NOTE Steps 5.3[30] and 5.3[31] may be repeated as necessary if rod motion is stopped prior to reaching doubling range. [30] WHEN any of the following conditions are met:

Source range count rate reaches or exceeds third doubling range determined in Appendix C OR

Control bank being withdrawn reaches 128 steps (requires verifying overlap in 0-SO-85-1) OR

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. [31] IF rod motion was stopped prior to reaching doubling range AND Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal to third doubling range USING 0-80-85-1. [32] IF source range count rate has reached or exceeded third doubling range, THEN PERFORM the following: [32.1] ENSURE rod motion STOPPED. [32.2] WAIT approximately 2-3 minutes to allow count rate to rise. DODD 0000 ( [32.3] NOTIFY Rx Engineering to perform ICRR calculations in accordance with 0-SI-NUC-000-001.0. [C.11] 0 [32.4] DETERMINE new count doubling range USING Appendix C.

( '. SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 56 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [33] IF ICRR plot indicates criticality will fall outside +/- 750 pcm ECC termination band, THEN [33.1] NOTIFY SM and Duty Plant Manager. [33.2] EVALUATE if ECC should be recalculated prior to continuing startup. [33.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. 0 [34] IF ICRR plot trend indicates acceptable ECC, TH_EN INITIATE rod withdrawal USING 0-SO-85-1 to fourth doubling range (App. C) or criticality. NOTE Steps 5.3[35] through 5.3[37] may be repeated as necessary if rod motion is stopped prior to reaching doubling range or criticality. [35] WHEN any of the following conditions are met:

Source range count rate reaches or exceeds fourth doubling range determined in Appendix C OR

Control bank being withdrawn reaches 128 steps (requires verifying overlap in 0-SO-85-1) OR

Bank D rods reach fully withdrawn position OR o

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. 0000

( SQN UNIT STARTUP FROM HOT STANDBY O-GO-2 Unit 0 TO REACTOR CRITICAL RevoOO26 Paqe 57 of 85 STARTUP No, _ Unit _ Date _ 503 Reactor Startup after a non-refueling outage (continued) [36] IF reactor is critical, THEN GO TO Step 5.3[59] (N/A Steps 5.3[37] through 5.3[58]). [37] IF ALL of the following conditions are met:

rod motion was stopped prior to reaching doubling range or criticality

Bank D rods are below fully withdrawn position

Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal USING 0-SO-85-1 to fourth doubling range or criticality (whichever comes first). [38] IF source range count rate has reached or exceeded fourth doubling range, THEN PERFORM the following: [38.1] ENSURE rod motion STOPPED. [38.2] WAIT approximately 2-3 minutes to allow count rate to rise. 0000 [38.3] NOTIFY Rx Engineering to perform ICRR calculations in accordance with 0-SI-NUC-000-001.0. [C011] 0 [38.4] DETERMINE new count doubling range USING Appendix C. [39] IF reactor is subcritical with Bank D rods at fully withdrawn position, THEN PERFORM Appendix E, Actions if Reactor is Subcritical with Rods Fully Withdrawn. 0

c SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 58 of 85 5.3 STARTUP No. Unit _ Reactor Startup after a non-refueling outage (continued) [40] IF IGRR plot indicates criticality will fall outside +/- 750 pcm EGG termination band, THEN [40.1] NOTIFY SM and Duty Plant Manager. [40.2] EVALUATE if ECG should be recalculated prior to continuing startup. Date _ [40.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. 0 [41] IF IGRR plot trend indicates acceptable EGG, TH_EN INITIATE rod withdrawal USING 0-SO-85-1 to fifth doubling range (App. G) or criticality. NOTE Steps 5.3[42] through 5.3[44] may be repeated as necessary if rod motion is stopped prior to reaching doubling range or criticality; [42] WHEN any of the following conditions are met:

Source range count rate reaches or exceeds fifth doubling range determined in Appendix G OR

Bank D rods reach fully withdrawn position OR o

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. [43] IF reactor is critical, THEN GO TO Step 5.3[59] (N/A Steps 5.3[44] through 5.3[58]). DODD

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 59 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refu eling outage (continued) [44) IF ALL of the following conditions are met:

rod motion was stopped prior to reaching doubling range or criticality

Bank D rods are below fully withdrawn position

Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal USING 0-80-85-1 to fifth doubling range or criticality (whichever comes first). [45) IF source range count rate has reached or exceeded fifth doubling range, THEN PERFORM the following: [45.1) ENSURE rod motion STOPPED. [45.2) WAIT approximately 2-3 minutes to allow count rate to rise. 0000 [45.3] NOTIFY Rx Engineering to perform ICRR calculations in accordance with 0-SI-NUC-000-001.0. [C.11] 0 [45.4) DETERMINE new count doubling range USING Appendix C. l (46) IF reactor is subcritical with Bank D rods at fully withdrawn position, THEN PERFORM Appendix E, Actions if Reactor is Subcritical with Rods Fully Withdrawn. o

( SON UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 60 of 85 5.3 STARTUP No. Unit _ Reactor Startup after a non-refueling outage (continued) [47] IF ICRR plot indicates criticality will fall outside +/- 750 pcm ECC termination band, THEN [47.1] NOTIFY SM and Duty Plant Manager. [47.2] EVALUATE if ECC should be recalculated prior to continuing startup. Date _ [47.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. 0 [48] IF ICRR plot trend indicates acceptable ECC, THEN INITIATE rod withd rawal USING 0-SO-85-1 to sixth doubling range (App. C) or criticality. NOTE Steps 5.3[49] through 5.3[51] may be repeated as necessary if rod motion is stopped prior to reaching doubling range or criticality. [49] WHEN any of the following conditions are met:

Source range count rate reaches or exceeds sixth doubling range determined in Appe ndix C OR

Bank D rods reach fully withdrawn position OR o (,

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. [50] IF reactor is critical, THEN GO TO Step 5.3[59] (N/A Steps 5.3[51] through 5.3[58]). 0000

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 PaQe 61 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [51] IF ALL of the following conditions are met:

rod motion was stopped prior to reaching doubling range or criticality

Bank D rods are below fully withdrawn position

Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal USING 0-SO-85-1 to sixth doubling range or criticality (whichever comes first). [52] IF source range count rate has reached or exceeded sixth doubling range, THEN PERFORM the following: [52.1] ENSURE rod motion STOPPED. [52.2] WAIT approximately 2-3 minutes to allow count rate to rise. D D D D [52.3] NOTIFY Rx Engineering to perform ICRR calculations in accordance with O-SI-NUC-OOO-001.0. [C.11] D [52.4] DETERMINE new count doubling range USING Appendix C. ( [53] IF reactor is subcritical with Bank D rods at fully withdrawn position, THEN PERFORM Appendix E, Actions if Reactor is Subcritical with Rods Fully Withdrawn. D

( - --- - - - SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Page 62 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [54] IF ICRR plot indicates criticality will fall outside +/- 750 pcm EGG termination band, THEN [54.1] NOTIFY SM and Duty Plant Manager. [54.2] EVALUATE if EGC should be recalculated prior to continuing startup. [54.3] IF startup must be aborted, THEN PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. D [55] IF IGRR plot trend indicates acceptable EGG, Tf-i!:N INITIATE rod withdrawal USING 0-SO-85-1 to seventh doubling range (App. G) or criticality. NOTE Steps 5.3[56] through 5.3[58] may be repeated as necessary if rod motion is stopped prior to reaching doubling range or criticality. [56) WHEN any of the following conditions are met:

Source range count rate reaches or exceeds seventh doubling range determined in Appendix G OR

Bank D rods reach fully withdrawn position OR D (

Operators or Rx Engineer determine that rod motion should be stopped THEN STOP outward rod motion. [57) IF reactor is critical, THEN GO TO Step 5.3[59] (N/A Step 5.3[58]). D D D D

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 63 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup aft er a non-refueling outage (continued) [58] IF ALL of the following conditions are met:

rod motion was stopped prior to reaching doubling range or criticality

Bank D rods are below fully withdrawn position

Unit Supervisor concurrence is obtained to resume, THEN RESUME rod withdrawal USING 0-SO-85-1 to seventh doubling range or criticality (whichever comes first). 0 0 0 0 [59) IF any of the following conditions exist:

- critical conditions cannot be achieved within the +/-750 pcm termination band OR

critical conditions cannot be achieved within the +/-1000 pcm allowable limits OR

critical conditions cannot be achieved above rod insertion limit OR l

reactor startup must be aborted for other reasons, THEN PERFORM the following to abort reactor startup: [C.11] [59.1) STOP rod withdrawal. [59.2) INITIATE insertion of control banks. [59.3) PERFORM Appendix 0 , Actions if Reactor Startup Must Be Aborted. [59.4) DO NOT CONTINUE this section. o

( SQN UNIT STARTUP FROM HOT STANDB Y 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 64 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [60] IF reactor is subcritical with Bank 0 rods at fully withdrawn position, THEN PERFORM Appendix E, Actions if Reactor is Subcritical with Rods Fully Withdrawn. 0 [61] IF reactor is critical with SUR less than 0.3 DPM AND intermediate range NIS is less than P-6 (1 X 10-4 %), THEN PERFORM the following: [61.1] IF Bank 0 control rods are BELOW fully withdrawn position, THEN OPERATE control rods to establish a positive SUR of approximately 0.3 DPM. [61.2] IF Bank 0 rods have reached fully withdrawn position AND Rx Engineering concurs with RCS dilution, THEN PERFORM RCS dilution (as recommended by Rx Eng) to establish positive SUR of approx. 0.3 DPM USING 0-SO-62-7.

c SQN UNIT STARTUP FROM HOT STANDBY 0*GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 65 of 85 5.3 STARTUP No. Unit _ Reactor Startup after a non-refueling outage (continued) IStart of Critical Step(s) Date _ NOTES 3) Blocking the SRM reactor trip with [HS-92-50011 and [HS-92-5002] will disable the detector outputs and remove the audio count rate signal. 4) Step 5.3[62] may be performed at time of criticality, if required. Source range reactor trip must be BLOCKED before trip setpoint of 105 cps. [62] WHEN annunciator XA-55-4A, window D-2 P-6 INTERMEDIATE RANGE PERMISSIVE is LIT, THEN [C.2] [62.1] RECORD both source range readings. N-31_ _ CPS N-32 CPS Initials [62.2] RECORD both intermediate range readings. N-35, %RTP N-36 %RTP Initials [62.3] VERIFY a minimum of one IRM channel greater than or equal to 1 X 10.4 % RTP. 0 [62.4] BLOCK source range reactor trip by momentarily placing [HS-92-5001] and [HS-92-5002] SRM TRIP RESET-BLOCK P-6 handswitches to BLOCK. Initials Time Date

( SQN UNIT STARTUP FROM HOT STANDBY O-GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Paqe 66 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [62.5] VERIFY annunciator XA-55-4A, window C-1 SOURCE RANGE TRAINS A & B TRIP BLOCK is LIT. IEnd of Critical Step(s) [62.6] SELECT NR 45 to record one intermediate range channel and one power range channel. [62.7] ADJUST NR 45 chart speed as desired. _ (N/A if no change needed). [63] ENSURE PA announcement made to notify plant personnel when the reactor is critical. NOTE o o o o When T-avg is less than 551°F and Tavg - Tref deviation alarm is lit, SR 4.1.1.4.b requires verifying lowest T-avg greater than or equal to 541 °F at least once per 30 minutes. [64] IF Tavg - Tref deviation alarm [M-5A window C-6] is LIT AND T-avg is less than 551°F, THEN PERFORM 0-SI-SXX-068-127.0 to satisfy SR 4.1.1.4.b, Minimum Temperature For Criticality.

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 67 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reactor Startup after a non-refueling outage (continued) [65) RAISE reactor power to approximately 1 X 10.3 'Yo: [65.1) IF Bank D control rods are BELOW fully withdrawn position, THEN OPERATE control rods to establish a positive SUR of approximately 0.5 DPM (not to exceed 1 DPM). [65.2) IF Bank 0 rods have reached fully withdrawn position AND Rx Engineering concurs with RCS dilution, THEN PERFORM RCS dilution (as recommended by Rx Eng) to establish positive SUR of approx. 0.5 DPM USING 0-SO-62-7. [65.3] _ WHEN intermediate range NIS indicate approximately 1 X 10.3 'Yo, THEN PERFORM the following: [65.3.1) STABILIZE reactor power using control rods. [65.3.2] RECORD critical data indicated below. Power Level: N-35 %RTP N-36 %RTP Rod Position: Bank Step RCS Boron concentration ppm Loop TAVG; 1 2 3 Initials 4 Time Date [66] VERIFY control rods above rod insertion limit USING 1,2-SI-OPS-000-002.0, Shift Log. [67) MAINTAIN reactor power stable with control banks above low insertion limit USING rod movement or boration/dilution to compensate for Xenon. o o

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 68 of 85 STARTUP No. _ Unit _ Date _ 5.3 Reacto r Startup after a non-refuel ing outage (continued) [68) IF start up is to continue with one or both MFPTs available, THEN [68.1) ENSURE Steps 5.1[13] through 5.1[15) have been completed for applicable pump(s). [68.2] VERIFY other applicable actions in Section 5.3 completed or initiated. [68.3] GO TO 0-GO-3, Power Ascension From Reactor Critical to Less Than 5% Reactor Power. [69) IF start up is to continue with NO MFPT available, THEN [69.1] MARK Steps 5.1[13) through 5.1[1 7] as "N/A". [69.2] VERIFY other applicable actions in Section 5.3 completed or initiated. [69.3) GO TO 0-GO-3, Power Ascension From Reactor Critical to Less Than 5% Reactor Power. [70] IF startup is to be discontinued, THEN GO TO 0-GO-6, Power Reduction From 30 % Reactor Power to Hot Standby. END OF TEXT

( saN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 69 of 85 6.0 RECORDS Completed copies shall be transmitted to the Operations Superintendent's Secretary.

( ( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 70 of 85 Appendix A (Page 1 of 1) DELETED 1.0 DELETED

( '. SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 71 of 85 Appendix B (Page 1 of 8) MODE 3 TO MODE 2,1 REVIEW AND APPROVAL 1.0 STARTUP No. Unit _ MODE 3 TO 2,1 REVIEW AND APPROVAL NOTE Date _ Steps in this Appendix may be performed out of sequence, except for those steps that pertain to the Operations Superintendent Hold Point. [1] PRIOR to entering Mode 2, 1, an SRO shall review the following: NOTE Mode 3 to Mode 2, 1 Checklist and Reactor Trip Breaker Checklist are to be attached to this instruction. A. Mode 3 to Mode 2,1 Checklists from the responsible sections and DETERMINE that the required surveillance testing for Mode 2 entry has been comp leted. Time Date B. Reactor Trip Breaker Closure Checklists from the responsible sections and DETERMINE that required surveillance testing for mode change has been comp leted. Time Date C. Active clearances for mode change restraints. [C.10]. Time Date D. TACF Books for outstanding alternations on systems prior to declaring a T.S. system or component operable. [C.10] Time Date

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 72 of 85 Appendix B (Page 2 of 8) 1.0 STARTUP No. Unit _ MODE 3 TO 2,1 REVIEW AND APPROVAL (continued) E. O-TI-EXX-OOO-001.0, Electrical Jumper Control Log to determine if any potential T. S. restriction exists which would prevent a mode change. Date _ Time Date F. Active Procedures Book to determine equipment status that may be abnormal. Time Date G. OPDP-4, Annunciator Disablement Log for alarms affecting operability of equipment required for mode change. Time Date H. O-PI-OPS-301-001.0 Plant Computer Point Disablement Log for alarms affecting operability of equipment required for mode change. Time Date I. Board walkdown is completed to verify proper equipment alignment. (Refer to appropriate CRO and OATe Pis for guidance) [C.10] Time Date

c - --- --------- SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 73 of 85 Appendix B (Page 3 of 8) 1.0 STARTUP No. Unit _ MODE 3 TO 2,1 REVIEW AND APPROVAL (continued) Date _ NOTE Tech Spec and TRM LCO 3.0.4 govern entering Mode 2 if any LCO requirement applicable in Mode 2 is not met. Therefore, mode change is not allowed while in a Tech Spec or TRM action UNLESS the exceptions and/or allowances stated in LeO 3.0.4 can be applied. J. REVIEW all Tech Spec and TRM Actions which have been entered on the affected unit and common equipment to verify that mode change is acceptable. SRO SRO Time Time Date Date

( SQN UNIT STARTUP FROM HOT STANDBY 0*GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Page 74 of 85 Appendix B (Page 4 of 8) 2.0 STARTUP No. Unit _ DEPARTMENT MANAGERS REVIEW Date _ 2.1 Periodic Test Coordinator: [1] ENSURE that all surveillance requirements for mode 2 entry are updated and included within the mode change checklist. Periodic Test Coordinator Time Date [2] ENSURE that all surveillance requirements for Reactor Trip Breaker Closure Checklist are updated and included within the checklist. [C.9) 2.2 Instrument Maintenance: Periodic Test Coordinator Time Date [1] ENSURE Wide Range SG Level Recorders [LR-3-43A) and [LR-3 -98A) are OPERABLE and SET to a range requested by the operator. (Recommended range between 80 and 90% of scale). [C.6] 2.3 Fire Ops Section: Instrument Maintenance Time Date l [1] ENSURE limitations as stated in 0-TI-SXX-000-016.0 are not exceeded . Fire Manager or Designee Time Date

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paae 75 of 85 Appendix B (Page 5 of 8) STARTUP No. _ 2.4 Systems Engineering Section: Unit _ Date _ [1) REVIEW of mode change checklist is complete and all surveillance requirements have met their acceptance criteria for Mode 2 entry. Shift Manager [2) REVIEW of Reactor Trip Breaker Closure Checklist is complete, all surveillance requirements have met their acceptance criteria, and all open items that affect mode change have been closed. Shift Manager NOTE Time Time Date Date The evaluation made by the Systems Engineer in the next step will prevent thermal shock to the PZR spray nozzle. [3] ENSURE PZR spray line bypass valves are throttled to maintain acceptable spray line temperature in accordance with 0-SO-68-3. System Engineering [4) IF startup is following a refueling outage, THEN ENSURE Present Cycle Core Operating Limit Report are inserted in the unit's Technical Specification Binder. [C.7) Licensing or designee Time Time Date Date

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 76 of 85 Appe ndix B (Page 6 of 8) STARTUP No. _ 2.5 Maintenance Section: Unit _ Date -r- [1 ] REVIEW of mode change checklist is complete and all surveillance requirements have met their acceptance criteria for Mode 2 entry. Shift Manager [2] REVIEW of Reactor Trip Breaker Closure Checkiist is complete, all surveillance requirements have met their acceptance criteria, and all open items that affect mode change have been closed. Shift Manager 2.6 Chemistry Section: NOTE Time Time Date Date The following step does not require a new analysis to be performed for this startup. Routine analysis is sufficient unless there is reason to suspect chemistry has been changed. [1] ENSURE reactor coolant chemistry within limits of Technical Requirements Manual 3.4.7 as determined by the Chemical Shift Supervisor. Chemical Shift Supervisor Time Date

( - ------ ---- SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Page 77 of 85 3.0 Appendix B (Page 7 of 8) STARTUP No. Un it _ SHIFT MANAGER (SM) HOLD POINT [1) ENSURE Tech Spec and non-Tech Spec work related activities are completed or will not prohibit entry or impact continued operation in Mode 2. Date _ SM Time Date [2] ENSURE no open DCN/ECNs that would prohibit a mode change. (SM concurrence with the Modifications Manager or designee). SM Time Date [3] REVIEW all open work activities relative to the unit for the purpose of iden tifying maintenance activities that could affect system ope rability prior to mode change l 8M [4] IF any potential Tech Spec. mode constraint exists, THEN OBTAIN Operations Superintendent reso lution prior to proceeding with the mode change 8M Time Time Date Date

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 78 of 85 3.0 Appendix B (Page 8 of 8) STARTUP No. Unit _ SHIFT MANAGER (SM) HOLD POINT (continued) Date _ [5] IF the startup follows a reactor trip or an emergency shutdown, THEN A. ENSURE cause of the trip/shutdown has been determined and will not impact Mode 2 entry. SM B. ENSURE Reactor trip report is comp lete. Time Date (O-TI-QXX-OOO-001.0, Event Critique, Post Trip Report, _ Equipment Root Cause and Outage Milestone PER Evaluation) SM Time Date C. ENSURE O-GO-12, Realignment of Secondary Equipment Following Reactor TripfTurbine Trip/Emergency shutdown, is comp lete. SM Time Date 4.0 OPERATIONS SUPERINTENDENT HOLD POINT Operations Superintendent or his designee concurs and grants approval to proceed to Mode 2, 1. Operations Superintend ent Time Date

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 UnitO TO REACTOR CRITICAL Rev. 0026 Paae 79 of 85 Appendix C (Page 1 of 1) DETERMING SOURCE RANGE COUNT RATE DOUBLING 1.0 Calculating Doubling Range NOTES 1) Source range reading shall be allowed to stabilize for approximate ly 3 minutes after each reactivity change prior to determining new stable count rate. 2) The highest reading channel should be used when determining stable count rate. Digital indication on shutdown monitor [M-13] is preferred. 3) Doubling range is used to determine when rod motion should be stopped during approach to criticality. Criticality is expected in about 5 to 7 count rate doublings. 4) This appendix may be performed and IV'd by operators, STA, or Rx Engineers. STABLE COUNT RATE DOUBLING RANGE INITIALS COUNT RATE (CR) CR X 1.75 = CR X 2.0 = 1st IV (Lower value not used for first doubling) End of Section

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 80 of 85 Appendix D (Page 1 of 1) ACTIONS IF REACTOR STARTUP MUST BE ABORTED STARTUP No. _ 1.0 Operator Actions Unit _---..,_ CAUTION Date _ If reactor trip is required, E-O should be performed instead of this appe ndix. [1 ] ENSURE all control bank rods FULLY INSERTED in accordance with 0-SO-85-1 . [2] LOG Mode 3 entry in narrative log. [3] VERIFY adequate shutdown margin in accordance with 0-SI-NUC-000-038.0. [4] Initials DETERMINE and CORRECT cause of the discrepancy. Time Date o \\. [5] WHEN reactor startup is to resume, THEN PERFORM the following: [5.1] RECALCULATE estimated critical conditions in accordance with 0-RT-NUC-000-003.0 (Startup after refueling) or 0-SI-NUC-000-001.0 (Startup after non-refueling outage). [5.2] DILUTE/BORATE in accordance with 0-SO-62-7 to the estimated critical boron concentration. [C.12] [5.3] EQUALIZE boron concentration (within 50 ppm) between reactor coolant loops and pressurizer by operating pzr heaters and spray. [C.12] [5.4] RE-INITIATE 0-GO-2. End of Document

(


~--=-=::----------

SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Pane 81 of 85 Appendix E (Page 1 of 2) ACTIONS IF BANK D RODS REACH FULL OUT POSITION PRIOR TO CRITICALITY 1.0 Operator Actions NOTE Allowabl e upper limit for critical position may be above the fully withdrawn position on Bank D. If Reactor Engineering determines that core response is within acceptable limits, this appendix allows RCS dilution to assist in achieving criticality. [1] CONSULT Reactor Engineering to determine if core response is within acceptable limits. D [2] IF projected critical rod position exceeds +1000 pcm limit OR startup will be aborted due to failing to achieve criticality, THEN [2.1] [2.2] PERFORM Appendix D, Actions if Reactor Startup Must Be Aborted. DO NOT CONTINUE this appendi x. D D [3] ENSURE control bank 0 inserted to less than or equal to estimated critical position determined in 0-RT-NUC-000-003.0 (Startup after refueling) or 0-SI-NUC-000-001 .0 (Startup after non-refueling outage). [4] DETERMINE dilution volume to increase core reactivity by 100 pcm OR as recommended by Rx Engineering. _____ gallons Rx Engineer IV

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Paqe 82 of 85 Appendix E (Page 2 of 2) STARTUP No. _ 1.0 Operator Actions (continued) Unit _ CAUTION Date _ NIS indications should be carefully monitored during and following dilution. [5] [6] PERFORM specified dilution USING 0-SO-62-7. WHEN at least 30 minutes has elapsed for ReS mixing AND Rx Engineer concurs with resuming startup, THEN RETURN to appropriate step (based on number of doublings) in Sect. 5.2 (Startup after refueling) or Section 5.3 (Startup after non-refueling outage). End of Document o o

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 83 of 85 Source Notes (Page 1 of 3) Requirements Statement Source Document Implementing Statement Verify MFWP trip bus energized before LER 328/88-014 C.1 entry into Mode 2. Revise GOI-2 to require verification of NCO 890118002 C.2 intermediate range (IR) status at LER 328/89006 approximately 20 and 25 percent, S53890531 844 verify source range (SR) status and JRB to NRC channel check at I ~wer power, monitor core delta Ts at low-power levels and during power escalation and compare with NIS response, and verify that the IR rod stop and trip bistables come in at the appropriate power level during power ascension. Following refueling operations SOER-90-003 C.3 relocation of NIS or modifications NCO 900107009 affecting the NIS response, provide NER 1187001 adequate reductions of trip setpoint LER 327/90011 R1 and limitations of reactor power until accuracy of the NIS is verified. Also, provide alternate indications of power independent of calorimetric calculations during power ascensions. Decommitted 3/12/99 C.4 Assurance that TSC computer is reset Verbal commitment to NRC at C.5 prior to startup ; defines "reset" and SNP Meeting 10104/90 "updating". (Modified C.5 permitting relaxing requirement.) Provisions to ensure that enhanced NCO 890097004 C.6 steam generator level recorders are L44 890505 805 ( operable in the main control room prior to entering mode 2.

( SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 84 of 85 Source Notes (Page 2 of 3) Requirements Statement Based upon the requirements of the May 6, 1991 PORC meeting this verification has been added to implement the referenced Technical Specification change for the Core Operating Limits Report. Consult Reactor Engineering for guidance during evolutions of unusual power maneuvers at end of core life. Provide reactor trip breaker closure checklists to ensure all surveillance requirements for reactor trip breaker closure are satisfied. Revise GOI-2 to include a step signoff with the TACF review, hold order review etc. section of GOI, for the Duty SOS to ensure a board walkdown to verify proper alignment is performed by a designated SRO prior to mode change. Operations startup procedures should: 1) Stress conservative actions and compliance with written procedures when repositioning control rods, 2) Guidance on actions when criticality will be achieved outside the ECC toleran ce band, 3) Avoid activities which distract the operators, 4) Directions to use pertinent instrumentation to monitor approach to criticality, 5) Periodic pauses during rod withdrawal. Source Document PORC Minutes #50880 5/06/91T/S 91-08 NER 89 0794 OER 89 3497 U1C5 Outage Critique item II S-92-045 SOER 88-02 NER 88047400 Implementing Statement C.7 C.8 C.9 C.10 C.11

(-, SQN UNIT STARTUP FROM HOT STANDBY 0-GO-2 Unit 0 TO REACTOR CRITICAL Rev. 0026 Page 85 of 85 Source Notes (Page 3 of 3) c. Requirements Statement Operator Controls and monitoring activities involving possible boron concentration reduction which could result in unplanned reactivity changes. Procedures that do NOT contain appropriate verification requirements will be revised. (This item is NOT annotated within the procedure, since the entire procedure must meet the verification program requirements. Source Document INPO SOER 94-002 TROI NCO 970071001 Implementing Statement C.12 C.13

( I ~

c .-- SQN UNIT STARTUP FROM HOT STANDBY a-GO-2 ) Unit a TO REACTOR CRITICAL Rev. 0025 Page 79 of 85 Appendix C (Page 1 of 1) DETERMING SOURCE RANGE COUNT RATE DOUBLING 1.0 Calculating Doubling Range NOTES 1) Source range reading shall be allowed to stabilize for aporoximately 3 minutes after each reactivity change prior to determining new stable count rate. 2) The highest reading channel should be used when determining stable count rate. Digital indication on shutdown monitor [M-13] is preferred . 3) Doubling range is used to determine when rod motion should be stopped during approach to criticality. Criticality is expected in about 5 to 7 count rate doublings. 4) This appendix may be performed and IVd by operators, STA, or Rx Engineers. -- STABLE COUNT RATE DOUBLING RANGE INITIALS , COUNT RATE (CR) CR X 1.75 = CR X 2.0 = 1st IV ZD (Lower value not used t.f:6 CY-- r;2- for first doubling) 4:0 70 I?O rtL ~ 00 13~ IS9 c.. ~ I S~ 2 7f ]('( 2- <>:: 3 1~ 5'50 4?3) 2- {.-- (j3 5 I {( ( /270 ~ ~ (2-7D 2 Z2-7.---- 2 SZiO W'---- ur- End of Section

c SON ESTIMATED CRITICAL CONDITIONS 0-SI-NUC-000-001 .0 0 Rev 5"::::::::- Page 35 of 42 "'. .. I I .. I I ",l, I APPENDIXC Page 8 of 10 MONITORING THE APPROACH TO CRITICALITY DATA SHEET C-1 ICRR DURING ROD WITHDRAWAL FOR CHANNEL N-32 UNIT \\ CYCLE DATE ,...-ro Oo')' ECC: PPM \\.5"~ STEPS T --' .. " e " ' A o "

'" ,,, "'I . "'I ... COUNT SECS Cr; BANK STEPS ICRR INITIALS CRO CR 1 CR2 CR3 CR4 CR5 CR6 CR7 CR8 CR9 i q - 1.00 /"-" 3 '1 .'1if r-/ 7 "\\'

Z-L/

A/ /,5 .. ,,1- ......... -';og' _ , t lo --- 6 / '<;' . u) "-- 12.7U .ciS -../' REACTOR ENGR REVIEWED BY--- -=:-:-::=-=-=0-==-- - DATE _

( l

( l TENNESSEE VALLEY AUTHOR ITY SEQUOYAH NUCLEAR PLANT SYSTEM OPERATING INSTRUCTION 0-50-85-1 CONTROL ROD DRIVE SYSTEM Revision 32 QUALITY RELATED PREPARED BY: JENNIFER REGAN RESPONSIBLE ORGANIZATION: OPERATIONS APPROVED BY: W. T. LEARY EFFECTIVE DATE: 1211112006 LEVEL OF USE: CONTINUOUS USE REVISION DESCRIPTION: Revised to incorporate the new reactor breaker close control switch, 2-HS-99-7, per DCN D21843A. PERFORMANCE OF THIS PROCEDURE COULD IMPACT REACTIVITY

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 2 of 77 TABLE OF CONTENTS Page 1 of 2 Section Title Page 1.0 INTRODUCTION 4 1.1 Purpose 4 1.2 Scope................................................................................................................ 4 2.0 REFERENCES.................................................................................................. 4 2.1 Performance References 4 2.2 Developmental References............... 4 3.0 PRECAUTIONS AND LIMITATIONS................................................................ 6 4.0 PREREQtJlSITE ACTIONS 9 5.0 STARTUP/STANDBYREADINESS................................................................. 10 5.1 Placing MG Set(s) in Standby Readiness......................................................... 10 5.1.1 Placing MG Set A In Service With MG Set B NOT Operating 12 5.1 .2 Placing MG Set B In Service With MG Set A NOT Operating 15 5.2 ReseUClose Reactor Trip Breakers 18 6.0 NORMAL OPERATION 21 6.1 Placing MG Set A In Service With MG Set B Operating 21 6.2 Placing MG Set B In Service With MG Set A Operating 30 6.3 Manual Operation of Rod Control System Below 15 Percent Power 39 6.4 Transferring from Manual to Auto Rod Control................................................. 52 6.5 Transferring from Auto to Manual Rod Control................................................. 53 7.0 SHUTDOWN..................................................................................................... 54 7.1 Removing the MG Set A From Service 54 7.2 Removing the MG Set B From Service 55

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 3 of 77 TABLE OF CONTENTS Page 2 of 2 Section Title Page 8.0 8.1 8.2 8.3 8.4 8.5 8.6 9.0 INFREQUENT OPERATION . Alternate Method of Paralleling MG Set A .. Alternate Method of Paralleling MG Set B .. Resetting Step Counters After Withdrawing Rods Above 231 Steps .. Resetting Step Counters After Inserting Rods Below 0 Steps .. Placing MG Set A In Service for Maintenance .. Placing MG Set B In Service for Maintenance .. RECORDS . 56 56 58 60 61 62 69 76 ( SOURCE NOTES 77 ATTACHMENTS ATTACHMENT 1: CONTROL ROD DRIVE SYSTEM POWER CHECKLIST 1-85-1 .01 ATTACHMENT 2: CONTROL ROD DRIVE SYSTEM POWER CHECKLIST 2-85-1.01

--- ---------


c SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 4 of 77 1.0 INTRODUCTION 1.1 Purpose This instruction provides the steps necessary for the operation of the Control Rod Drive System. 1.2 Scope This instruction provides detailed steps for the following operations: Placing Control Rod Drive MG Sets in Service Removing Control Rod Drive MG Sets from Service Parallel Operation of Control Rod Drive MG Sets Manual Operation of the Control Rod Drive System Transferring Rod Control from Manual to Auto Transferring Rod Control from Auto to Manual 2.0 REFERENCES 2.1 Performance References A. Procedures 1. 0-SI-NUC-000-038.0, Shutdown Margin 2. 1,2-PI-IFT-099-0P4.0, Verification of P4 Contacts B. Tech Specs 1. 3.4.1.2 C. Westinghouse Tech. Bulletin NSD-TB-92-05RO 2.2 Developmental References A. Tech Specs 1. 3.1.3.1 2. 3.1.3.2 3. 3.1.3.4 4. 3.1.3.5 5. 3.1.3.6

( ' . c SQN CONTROL ROD DRIVE SYSTEM 0-80-85-1 1,2 Rev 32 Page 5 of 77 2.0 REFERENCES (Continued) B. Technical Requirements Manual 1. TR 3.1.3.3 C. F8AR 1. 7.7.1.2.1 D. TVA Drawings 1. 45N699-1 2. 45N777-3 3. 45N703-1, 2, 3,4 4. 45N1646-4 5. 45N2646-4 6. _ 45N1624-1, 2, 3,4, 5, 8 7. 45N2624-1, 2, 3,4, 5, 8 8. 617F619

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1.2 Rev 32 Page 6 of?? 3.0 PRECAUTIONS AND LIMITATIONS A. Rod thermal lock-up is NOT a concern when the reactor trip breakers are OPEN. If reactor trip breakers are CLOSED and an RCS cooldown of greater than 50°F is planned , the shutdown and control banks should be withdrawn at least 5 steps each . This will limit the possibility of "thermal lock- up" of the rods. This does not apply if performing sections 8.5 or 8.6. B. If both MG sets are to be shutdown, the control rods and shutdown rods shall be inserted in the core and the reactor trip breakers OPEN prior to shutting down the MG sets. C. Reactor Trip Breakers shall NOT be closed while in Mode 3 unless in compliance with LCO 3.4.1.2. D. Failure to perform 1,2-PI-IFT-099-0P4.0, Verification of P4 Contacts could result in the prevention of AUTO SI if required. E. Under normal conditions, the control rod banks must be withdrawn and inserted in the prescribed sequence. For withdrawal the sequence is Shutdown Bank A, Shutdown Bank B, Shutdown Bank C, Shutdown Bank D, Control Bank A, Control Bank B, Control Bank C, and Control Bank D. The insertion sequence is the reverse of the withdrawal sequence. F. For manual bank sequencing , the prescribed withdrawal and insertion sequence should be followed . Rod motion of the correct bank should be monitored by observing the group step counters and the rod position indicators. G. During Control Rod withdrawal, the Controi Banks should be monitored for bank overlap . H. The control banks must be maintained above their respective insertion limits (Low-Low Alarm to ensure adequate shutdown in the event of a reactor trip, to ensure that maximum possible ejected rod reactivity limits are maintained and to ensure acceptable core power distributions. I. Before withdrawing any rod bank from the fully inserted position, the group step counters and the rod position indicators for that bank must be at zero steps.

c SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 7 of 77 3.0 PRECAUTIONS AND LIMITATIONS (Continued) J . Deleted K. The Control Rods shall NOT be stepped or tripped unless the RCS pressure is at least 100 psig. L. RPls and step counters shall be maintained within limits per TS 3.1.3.1 and 3.1.3.2. M. Continuous rod motion shall comply with these restrictions: CRDM OUTLET ROD MOTION LIMITS TEMPERATURE " 190°F 10 minutes ON 20 minutes OFF " 200°F 6 minutes ON 24 minutes OFF Time limitations are due to a lower air flow rate of 48,000 cfm across the shroud combined with a higher temperature (Reference TSIR-97-BOP-30-636 and Westinghouse Letters RIM's #B38931005806, B38930920800, and 8 38931 005803). N. The following failures will render the rod control system incapable of automatic and / or manual motion without any annunciation or indication: 1) Hand switch failure; 2) relay failure, and 3) failure of both 100v DC power supplies (PS3 and PS6) simultaneously. O. Defeating or restoring Tavg/Delta T or NIS channel may cause step change in input to rod control. A delay of at least 3 minutes prior to returning rod control to automatic will allow lead/lag signal to decay off.

( SON CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 8 of 77 3.0 PRECAUTIONS AND LIMITATIONS (Continued) P. Directional Overcurrent Relay Targets are reset by depressing the Relay Target Reset Pushbutton on the panel to break the target coil seal in circuit and then lifting the mechanical reset at the bottom of the relay cover. Q. US I SRO Oversight for control rod manipulation shall include : 1. Prior to Rod Movement a. Ensure RPI's within T.S. range (+ or - 12 steps) b. Ensure delta flux will not be adversely affected c. Ensure Tavg and Rx Thermal power will not be adversely affected d. Verify on target with Rx Eng reactivity balance sheet e. Verify power change will not exceed hourly rate f. Ensure no simultaneous reactivity manipulations in progres s (Le.: borations, dilutions or turbine load change s) 2. During Rod Movement a. Ensure RO has peer check b. Ensure RO is following procedure c. Ensure RO understands how many steps they are moving rods d. Ensure RO has checked all the above mentioned items e. Watch performance of rod manipulation while listening to audible indication of rod step f. Ensure peer check is doing their job g. Re-verify steps a - d of initial evaluation h. Ensure procedure is followed placing rods back to auto (Tavg - Tref mismatch) L Monitor plant for expected response

---====----"==~ .== = = =='----._---- (' SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 39 of 77 Unit ( Date 'tH~ 6.3 Manual Operation of Rod Control System Below 15 Percent Power CAUTION If reactor trip breakers are CLOSED and an RCS cooldown of greater than 50°F is planned, the shutdown and control banks should be withdrawn at least 5 steps each. This will limit the possibility of "thermal lock-up" of the rods. Thermal lock-up is NOT a concern during unit heatup. NOTE Continuous rod motion shall comply with these restrictions : CRDM OUTLET ROD MOTION LIMITS TEMPERATURE <190°F 10 minutes ON 20 minutes OFF <200°F 6 minutes ON 24 minutes OFF [1] ENSURE Section 5.2, Reset/Close Reactor Trip Breakers has been compieted. [2] IF the shutdown and control rods were withdrawn 5 steps to prevent thermal lockup during an RCS cooldown, THEN ENSURE rods are fully inserted prior to withdrawal. ,Itt. 1MM5- 1st cv [3] MOMENTARILY PLACE [SUS], Rod Control Startup Step Counter Reset to the STARTUP position to reset Control Rod Drive System. c. NOTE CAUTION ROD CONTROL STARTUP STEP COUNTER RESET (SUS on M-4) Resets: A. All GROUP STEP COUNTERS on the Control Board. B. The master cycler reversible counter. C. All slave cycler counters. D. The bank overlap counter. E. All internal memory and alarm circuits. F. All pulse-to-analog converters in the Rod Position Indication System. ROD CONTROL STARTUP STEP COUNTER RESET (SUS on M-4) should never be held in STARTUP position for any extended period of time. Holding this switch in STARTUP position may cause damage to the counters.

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 40 of 77 Unit Date J1l/)"'1 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) CAUTION . Before withdrawing any rod from the fully inserted position, all Group Step Counters and all Rod Position indicators must be at zero steps. ( [4] ENSURE all Full Length Rod step counters reset to zero. [5] VERIFY rod control IN-OUT direction lights are NOT LIT. [6] DEPRESS [RCAS], Rod Urgent Failure Alarm Reset. [7] RESET Window 6 (A-6), ROD CONTROL SYSTEM URGENT FAILURE alarm on panel [XA*55-4B] using [XS-55-4A], Annunciator RESET/ACKITEST Switch. [8] VERIFY the following rod control system alarms on panel [XA-55-4B] are NOT LIT: WINDOW NOT LIT NUMBER N) 5 (A5) IB' 6 (A6) ~ 11 (B4) IE"' 12 (B5) 10" 13(B6) iW 18 (C4) Il:i1 19(C5) ~ 27 (06) &r 34 (E6) 1!6 11/

( SQN CONTROL ROD DRIVE SYSTEM 0-50-85-1 1,2 Rev 32 Page 41 of 77 Unit I Date 110"1 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) [9] ENSURE Plant computer points for rod bank position are ZERO using the following computer points : COMPUTER PT ROD BANK -,J U0049 Control A [JJ'" U0050 Control B lit" U0051 Control C Ii;1( U0052 Control D [B'" U0053 Shutdown A I!2f U0054 Shutdown B IB'" U0055 Shutdown C IB" - U0056 Shutdown D ~ [10] MONITOR Control Rod position USING Rod Position Indicators ICS screen 30 minute trend during SD & Control Banks with drawal to aid in detecting rod misalignm ent. [11] IF Individual Rod Position Indication does not indicate proper rod position during withdrawal of SD Banks, THEN [a] STOP rod withdrawa l. f.Zif? [b] ENSURE subcriticality. k!jJ:J [e] CONTACT MIG AND INITIATE troubleshooting. I!jlt [d] IF troubleshooting does not resolve the problem , OR sub criticality can NOT be verified, THEN INITIATE Reactor TRIP. iliff [12] IF Individual Rod Position Indication does not indicate proper rod position during withdrawal of Control Banks, THEN GO TO AOP-C.01 section 2.6 Rod Position Indicator (RPI) Malfunction - Modes 1 or 2. ~A

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 42 of 77 Date TIJ0'1 ( Unit. -'- _ 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) CAUTION Under normal conditions control rod banks must be withdrawn and inserted in the prescribed sequence. For withdrawal, the sequence is Shutdown Bank A, Shutdown Bank B, Shutdown Bank C, Shutdown Bank D, Control Bank A, Control Bank B, Control Bank C, Control Bank D. The insertion sequence is the reverse of the withdrawal seq uence. NOTE 1 Startup rate, Source range, Intermediate range, Nuclear Instrumentation recorders, Group Step Counters and the Rod Position Indicators should be monitored during each bank withdrawal. NOTE 2 1lL 1 ~ 1st CV [13] The following failures will render the rod control system incapable of automatic and / or manual motion without any annunciation or indication: 1) Hand switch failure; 2) relay failure, and 3) simultaneous failure of both 100v DC power supplies (PS3 and PS6) PLACE [HS*S5-51101, Rod Control Mode Selector to the SBA position. [14] VERIFY Rod Speed Indicator [SI-412]. indicates 64 Steps/minute. 1!I£. / ~ 1st CV

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 43 of 77 Unit --:(___ Da te-L=~_ 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) NOTE Monitor Group Step Counters, Rod Position Indicator and the "IN-OUT" status lights to ensure anticipated motion as each bank is being withdrawn. Rod speed indicator should be reading 64 steps per minute. ~ /IIIW 1st CV ( [15] ENSURE Shutdown Bank A demand position counters operational by performing the following: [C.2] [a] BUMP [HS-85-5111] , Rod Control Switch to withdraw Shutdown Bank A one-half step at a time, for one full step. ~ I /11M( 1st cv [b] CHECK group demand position counters advance properly. [c] BUMP [HS-85-5111] to withdraw Shutdown Bank A one-half step at a time, for the second full step. JJ1L /~ 1st CV [d] VERIFY group demand position counters advance properly. [e] IF group demand position counters do NOT advance properly, THEN A. STOP rod withdrawal. .Q2>>. B. INITIATE WO to have counter repaired. fi[1r C. WHEN counter is repaired, THEN 1. ENSURE Shutdown Bank A fully INSERTED. ~ 2. RETURN to beginning of this step. ,fjd- NOTE The fully withdrawn position for shutdown and control rods is defined by TI-28, Atl. 6. [16] WITHDRAW Shutdown Bank A to the FULLY WITHDRAWN position using [HS-85-5111].

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 44 of 77 ,( /t( I /UW{ 1st CV Unit. 1 Date'--L"""'"tDJ-_ 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) [17] PLACE IHS-85-5110], Rod Control Mode Selector to the SBB position. [18] VERIFY Rod Speed Indicator [51-412], indicates 64 Steps/minute. NOTE The following failures will render the rod control syste m incapable of automatic and / or manual motion without any annunciation or indication: 1) Hand switch failure; 2) relay failure, and 3) simultaneous failure of both 100v DC power supplies (PS3 and PS6). .iJtL I AlI'i. 1st cv [19] ENSURE Shutdown Bank B demand position counters operational by performing the following: [C.2] [a] BUMP [HS-85-5111], Rod Control Switch to withdraw Shutdown Bank B one-half step at a time , for one full step. [b] CHECK group demand position counters advance properly. [c] BUMP [HS-85-5111] to withdraw Shutdown Bank B one-half step at a time, for the second full step . dIf!- I 1I'fJ-'i 1st cv [d] VERIFY group demand position counters advance properly. ~ /~ 1st CV [e] IF group demand position counters do NOT advance properly, THEN A. B. C. STOP rod withdrawa l. INITIATE WO to have counter repaired. WHEN counter is repaired, THEN 1. ENSURE Shutdown Bank B fully INSERTED and 2. RETURN to beginning of this step. [20] WITHDRAW Shutdown Bank B to the FULLY WITHDRAWN position using [HS-85-5111].

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 45 of 77 ~ I MfI"l. 1st CV Unit. --'-{___ Date--l.-=-""=f-_ 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) [21] PLACE [HS-85-5110], Rod Control Mode Selector to the SBC position. [22] VERIFY Rod Speed Indicator [SI-412], indicates oSteps/minute. AJ.<, /~ 1st CV NOTE The following failures will render the rod control system incapable of automatic and / or manual motion without any annunciation or indication: 1) Hand switch failure; 2) relay failure , and 3) simultaneous failure of both 100v DC power supplies (PS3 and PS6). [23] ENSURE Shutdown Bank C demand position counters operational by performing the following : [C.2] [a] BUMP [HS-85-5111], Rod Control Switch to withdraw Shutdown Bank C one full step. !JtL I MJVI.. 1st CV [b] CHECK group demand position counter advances properly. [c] BUMP [HS-85-5111] to withdraw Shutdown Bank C a second full step. "-It< I ~ 1st CV [d] VERIFY group demand position counter advanced properly.

flf( I MWJ2

1st CV tel IF group demand position counters do NOT advance properly, THEN A. B. C. STOP rod withdrawal. INITIATE WO to have counter repaired. WHEN counter is repaired , THEN 1. ENSURE Shutdown Bank C fully INSERTED and 2. RETURN to beginning of this step. [24] WITHDRAW Shutdown Bank C to the FULLY WITHDRAWN position using [HS-85-5111]. (

c SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 46 of ?? Unit I Date 7Tf{Jtry 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) [25] PLACE [HS-85-511 OJ, Rod Control Mode Selector to the SBD position. .llt..i- I 111M 1st CV [26] VERIFY Rod Speed Indicator [SI-412], indicates oSteps/minute. I't/I<. I ...!J!..1!!l 1st CV NOTE The following failures will render the rod control system incapable of automatic and / or manual motion without any annunciation or indication: 1) Hand switch failure; 2) relay failure, and 3) simultaneous failure of both 100v DC power supplies (PS3 and PS6). [27] ENSURE Shutdown Bank 0 demand position counters operational by performing the following: [C.2] [a] BUMP [HS-85-5111], Rod Control Switch to withdraw Shutdown Bank 0 one full step. J!.l!:S..- I ~ 1st CV [b] CHECK group demand position counter advances properly. [c] BUMP [HS-85-5111] to withdraw Shutdown Bank 0 a second full step. ~ l tHJIL 1st CV [d] VERIFY group demand position counter advanced properly. I!ft I AIW' 1st CV [e] IF group demand position counters do NOT advance properly, THEN A. B. C. STOP rod withdrawal. INITIATE WO to have counter repaired. WHEN counter is repaired, THEN 1. ENSURE Shutdown Bank 0 fully INSERTED and 2. RETURN to beginning of this step. [28] WITHDRAW Shutdown Bank D to the FULLY WITHDRAWN position using [HS-85-5111].

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 47 of 77 Unit 6.3 ) Date !7If'1 Manual Operation of Rod Control System Below 15 Percent Power (Continued) NOTE Remainder of this section performed in conjunction with 0-GO-2 or 0-RT-NUC-OOO-003.0. [29] PLACE [HS-85-5110], Rod Control Mode Selector to the MANUAL position. [30] VERIFY Rod Speed Indicator [SI-412] , indicates 48 Steps/minute. Jl/f( , AIM. 1st cv 11 #<. , Awl t st CV NOTE The following failures will render the rod control system incapable of automatic and / or manual motion without any annunciation or indication: 1) Hand switch failure; 2) relay failure, and 3) simultaneous failure of both 100v DC power supplies (PS3 and PS6). [31] ENSURE Control Bank A demand position counters operational by performing the following: [C.2] [a] BUMP [HS-85-5111], Rod Control Switch to withdraw Control Bank A one-half step at a time, for one full step. [b] CHECK group demand position counters advance properly. [c] BUMP [HS-85-5111] to withdraw Control Bank A one-half step at a time, for the second full step. !1J.ti.. IAtr l s i CV AIIf.. , ~ 1st CV [d] VERIFY group demand position counters advance properly. QV tel IF group demand position counters do NOT advance properly, THEN A. STOP rod withdrawal. ~ B. INITIATE WO to have counter repaired. f/'P- C. WHEN counter is repaired, THEN 1. ENSURE Control Bank A fully INSERTED and Af1J} 2. RETURN to beginning of this step. ~

( saN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 48 of 77 Unit ( Date 1vl?o9-!p 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) [32] CONTINUE withdrawal of Control Bank A using [HS-85-5111] , IJlL( Rod Control Switch to 128 steps or next doubling. "'F, NOTE When Control Bank A is above 20 steps. alarm FULL LENGTH RODS AT BOnOM light on [XA-55-4B] should clear. When Control Bank A gets above 20 steps and rods are driven back in, the alarm will come back in. When Control Banks B, C, and 0 get above 35 steps, then drop below 20 steps, the alarm will come back in. [33] WHEN Control Bank A is above 20 steps, THEN ENSURE Window 28 (0-7). FULL LENGTH RODS RODS AT BOnOM alarm on panel [XA-55-4B] CLEARS.

( SQN CONTROL ROD DRIVE SYSTEM 0-50-85-1 1,2 Rev 32 Page 49 of 77 Unit I Date iWA-y 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) CAUTION When Control Bank A is reaches 128 steps, Control Bank B should begin to move. Each successive bank should begin to move when the previous bank reaches 128 steps. [34] WHEN Control Bank A is withdrawn to 128 steps, THEN ENSURE Control Bank B demand position counters operational by performing the following: [C.2] [a] BUMP [HS-85-5111J, Rod Control Switch to withdraw Control Bank B one-half step at a time, for one full step. "# f AW t.. 1st cv [b] - CHECK group demand position counters advance properly. [e] BUMP [HS-85-5111] to withdraw Control Bank B one-half step at a time, for the second full step. .!:!I:L f M CI't t st cv [d] VERIFY group demand position counters advance properly. [e] IF group demand position counters do NOT advance properly, THEN A. B. C. STOP rod withdrawal. INITIATE WO to have counter repaired. WHEN counter is repaired, THEN 1. ENSURE Control Bank B fully INSERTED and 2. RETURN to beginning of this step. [35] CONTINUE withdrawal of Control Bank Busing [HS-85-5111] to 128 steps or next doubling. c.

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 50 of 77 t1.JfL ,IIJ-ld- 1st CV Unit 6.3 { Da~ WR~ Manual Operation of Rod Control System Below 15 Percent Power (Continued) [36] WHEN Control Bank B is withdrawn to 128 steps, THEN ENSURE Control Bank C demand position counters operational by performing the following: [C.2] [a] BUMP [HS-85-5111] , Rod Control Switch to withdraw Control Bank C one-half step at a time, for one full step. [b] CHECK group demand position counters advance properly. [c] BUMP [HS-85-5111] to withdraw Control Bank C one-half step at a time, for the second full step. [d] _ VERIFY group demand position counters advan ce properly. m , MWI- 1st cv [e] IF group demand position counters do NOT advance properly, THEN A. STOP rod withdrawal. R)f B. INITIATE WO to have counter repaired. ~ C. WHEN counter is repaired , THEN 1. ENSURE Control Bank C fully INSERTED and ~ 2. RETURN to beginning of this step. ~ [37] CONTINUE withdrawal of Control Bank C using [HS-85-5111] to 128 steps or next doubling. I.It{ NOTE Three steps are added to the low-low insertion limit (110 steps @ zero power) until LEFM is available. [38] WHEN Control Bank C is '" 113 Steps, THEN ENSURE Window 14 (B-7), ROD CONTROL BANKS LIMIT LOW-LOW alarm on panel [XA-55-4B] CLEARS. LIf(

( SQN CONTROL ROD DRIVE SYSTEM 0-SO-85-1 1,2 Rev 32 Page 51 of 77 Unit I Date ]uO""1 6.3 Manual Operation of Rod Control System Below 15 Percent Power (Continued) NOTE Three steps are added to the low insertion limit (120 steps @ zero power) until LEFM is available. [39] WHEN Control Bank C is '" 123 steps. THEN ENSURE Window 7 (A-7). ROD CONTROL BANKS LIMIT LOW alarm on panel [XA-55-4B] CLEARS. [40] WHEN Control Bank C is withdrawn to 128 steps. THEN ENSURE Control Bank D demand position counters operational by performing the following: [C.2] [a] BUMP [HS-85-5111]. Rod Control Switch to withdraw - Control Bank D one-half step at a time, for one full step. JlIf( I NtJil. 1st cv [b] CHECK group demand position counters advance properly. [i} [c] BUMP [HS-85-5111] to withdraw Control Bank D one-half step at a time, for the second full step. ~ I /J(if/. 1st CV [d] VERIFY group demand position counters advance properly. [)" [e] IF group demand position counters do NOT advance properly. THEN A. STOP rod withdrawal. i!1.4 B. INITIATE WO to have counter repaired. If/JI C. WHEN counter is repaired, THEN 1. ENSURE Control Bank D fully INSERTED and ~ 2. RETURN to beginning of this step. ~ [41] CONTINUE withdrawal of Control Bank D using [HS-85-5111] to next doubling or criticality. End of Section 6.3

l

( SQN ROD CONTROL SYSTEM MALFUNCTIONS AOP-C.01 Rev. 16 I STEP I ACTION/EXPECTED RESPONSE 2.1 Continuous Rod Bank Movement 1. CHECK rod control: a. ENSURE rod control in MAN. b. CHECK rod motion STOPPED. RESPONSE NOT OBTAINED b. TRIP the reactor, and GO TO E-O, Reactor Trip or Safety Injection. --~.-- CAUTION: - Control Rods should NOT be manually withdrawn during a plant transient. 2. CHECK for steam line or feedwater line break: ( a. CHECK for rising reactor power with dropping T-avg. b. GO TO AOP-S.05, Steam Line or Feedwater Line Break/Leak. --~.-- a. GO TO Step 3. Page 5 of 62

( ( PREPAREDI REVISED BY: JPM B.1 .b Page 1 of 14 Rev. 11 SEQUOVAHNUCLEARPLANT JOB PERFORMANCE MEASURE B.1.b JPM 77-2AP Perform DIG Load Test on 1B-B DIG (with low oil press) Date/ VALIDATED BY: APPROVED BY: CONCURRED:

(Operations Training Manager) (Operations Representative) Datel Datel Date/

  • Validation not required for minor enhancements, procedure Rev changes that

do not affect the JPM, or individual step changes that do not affect the flow of the JPM.

    • Operations Concurrence required for new JPMs and changes that affect the

flow of the JPM (if not driven by a procedure revision).

( (, JPM B.1.b Page 2 of 14 Rev. 11 NUCLEAR TRAINING REVISION/USAGE LOG REVISION DESCRIPTION OF V DATE PAGES PREPARED/ NUMBER REVISION AFFECTED REVISED BY: 7 Revised to reflect revision changes in SI- N 10/14/99 All SR TAYLOR 7B, changed critical steps for consistency with JPM 77-5AP reviewed/approved 4/20/99, corrected typos and incorporated comments from 1999 cycle 5 requal performances of JPM 77-2AP. Flow of the JPM is not affected. penlink Deleted step 20 based on rev 20 of O-AR* N 8/9/00 5,12 SR Taylor M26-B , Updated rev level penlink SO-82 rev update only N 8/17/00 4 SR Taylor penlin k 0-AR-M26-B rev chg only N 8/28/00 4 SR Taylor penli nk 0-SI-OPS-082-007.B rev chg only N 6/21/01 4 W R Ramsey pen/ink 1-SI-OPS-082-007.B rev 25 Update minor N 09/07/01 ALL WR Ramsey changes related to stopwatch usage 8 Incorporated pen/ink changes ; updated to N 8/20/02 All J P Kearney recent revisions of references; no impact on JPM flow 9 Revised remote functions used to conform N 12/01/2003 4,8, 10 JJ Tricoglou to new simutator configuration 10 Updated to curre nt revisions and IC. N 8/11/04 All MG Croteau 11 Updated to current revisions . Minor format N 01/31/07 All RH Evans chan ges v-Specify if the JPM change will require another validation (Y or N). See cover sheet for criteria.

( JPM B.1.b Page 3 of 14 Rev. 11 SEQUOYAH NUCLEAR PLANT ROISRO JOB PERFORMANCE MEASURE Task: Perform DIG Load Test on 18-B DIG JAITA tas k # : 0640020101 0640040101 0640060101 (RO) KIA Rati ngs: 064A4.01 (4.0/4.3) 064A4.02 (3.3/3.4) 064A2.09 (3.1/3.3) 064A1.01 (2.0/3.1) 064A4.03 (3.213.3) 064A3.06 (3.3/3.4) Task Standard : Perform DIG Operability Test per 1-SI-OPS-082-007.B. specifically manually start the DIG. Open alternate ERCW supply valve and emergency stop DIG on low oil pressure annunciator. Evaluation Method : Simulator _ -!:X,--_ In-Plant _

=======================================================================

Performer: NAME Start Time ( Performance Rating: SAT UNSAT Performance Time Finish Time Evaluator: I SIGNATURE DATE

========================================================================

COMMENTS ('

( SPECIAL INSTRUCTIONS TO EVALUATOR: 1. Sequenced steps identified by an "s" 2. Any UNSAT requires comments 3. Acknowledge any associated alarms. 4. Initialize Simulator to IC-16. 5. A Console operator will be required to enter overrides and play role of AUO on Radio. 6. When operator starts step #19, insert IMF AN_OV_946 f:2. 7. An extra simulator operator will be needed at step 5 for timing the D/G. 8. Ensure operator performs the following required actions for SELF-CHECKING; a. Identifies the correct unit, train, component, etc. b. Reviews the intended action and expected response. c. Compares the actual response to the expected response. Validation Time: CR 13 minutes Local _ Tools/Equipment/Procedures Needed: Marked up portions of 1-SI*OPS-082-007.B:

Section 4;

Section 6.1; and,

Appendix "C". O-AR-M26-B window B-4 References' JPM B.1.b Page 4 of 14 Rev. 11 ( Reference Tille Rev No. 1. 1-SI-OPS-082-007.B Electrical Power System Diesel Generator 1B-B 39 2. O-AR-M26-B Annunciator O-XA-55-26B 27

( ( JPM B.1.b Page 5 of 14 Rev. 11

==================================================================

READ TO OPERATOR Directions to Trainee: I will explain the initial conditions , and state the task to be performed. All control room steps shall be performed for this JPM. I will provide initiating cues and reports on other actions when directed by you. Whe n you complete the task successfully, the objective for this job performance measure will be satisfied. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you. INITIAL CONDITIONS: 1. Both units are at 100% RTP. 2. All systems are OPERABLE, except for the 1B-B DIG, 0-GO-16 has been completed on all the A train equipment. 3. Maintenance has been completed on the 1B-B DIG and the clearance has been removed. 4. The DIG has been rolled and is in standby alignment using 0-SO-82-2. 5. The AUO at the DIG building has completed Appendix A of 1-SI-OPS-082 *007.B and all parameters are within limits. 6. The U1 Control Room AUO has verified breaker 1934 is removed. 7. SI-166.36 is NOT required. 8. D/G-DAQ has been installed. 9. Room fire protection is in service. 10. Section 4.0 of 1-SI-OPS-082-007.B is complete. INITIATING CUES: 1. The U1 US/SRO has reviewed the completed work package for the 1B-B DIG, all that remains is to perform 1-SI-OPS-082-007.B for the PMT. 2. You are an extra unit operator and have been assigned to perform the operability run of DIG 1B-B per SI-OPS-082-007.B. 1. The PMT requires the AMBIENT MANUAL START method for testing. 3. Notify the US when the test is complete.

Job Pertormance Checklist: STEP/STANDARD JPM B.1.b Page 6 of 14 Rev. 11 SATIUNSAT ( ( ( STEP 1.: Operator obtains a copy of the appropriate procedure. - SAT NOTE: Initial conditions cover steps up to transition to App "C". - UNSAT STANDARD: Operator obtains a copy of 1-SI-OPS*082-007.B. Pertormance of task Start Time- - will start with AppendiX C. COMMENTS: STEP 2.: [1) ENSURE [D-HS*82-48) . 1B-B D/G mode selector switch in the UNIT - SAT position. - UNSAT STANDARD: O-HS-82-48 in UNIT position on O-M-26. Green light ON. COMMENTS: STEP 3.: [2) Place [1*HS*57*74). D/G 1B-B Synchronize Switch in the SYN position. - SAT NOTE: O*EI*82*35 and O*XI*82*33 will indicate running voltage & frequency. - UNSAT STANDARD: 1-HS-57-74 in "SYN" position on O-M-26. This step is critical to allow to allow DIG to be synchronized to the Shutdown Bd. Critical Step COMMENTS:

Job Performance Checklist: STEPISTANDARD JPM B.1.b Page 7 of 14 Rev. 11 SAT/UNSAT ( c STEP 4. [3] PERFORM the following to initiate the DIG start signal: - SAT [a] IF the D/G-DAQ is to be used, THEN NOTIFY D/G-DAQ - UNSAT Operator to START the D/G-DAQ NOTE: Operator should coo rdinate the start of the D/G-DAQ just prior to DIG start actuation. Cue Console operator Play role of DIG-DAQ operator: DIG-DAQ computer is running. STANDARD: Operator notifies the DIG-DAQ operator to start the DIG-DAQ. COMMENTS: STEP 5.: [b] PROCEED with the countdown: 3,2,1, START. - SAT [c] DEPRESS [0-HS-82-46A]. DG 1B-B Emergency Start Switch - UNSAT AND START stopwatch. [d] WHEN voltage >6800 volts AND frequency >58.8 Hz, THEN Critical Step STOP stopwatch. CUE: An extra operator with stop watch is standing by. STANDARD : D-HS-82-46A momentarily depressed . Green light will go "out" and red light will com e "on" above DIG mimic. [Not critical: DIG running aiarm will ANN to indicate DIG> 40 rpm. Incoming voltage and frequency are verified on 0-EI-82-34 and 0-XI-82-32. Portions of this step is critical to start the DIG. COMMENTS: STEP 6.: [4] ENSURE [1-FCV-67-67], ERCW cooling water supply valve is OPEN. - SAT - UNSAT STANDA RD: ERCW valve 1-FCV-67-67 is verified open. COMMENTS:

Job Performance Checklist: STEPISTANDARD JPM B.1.b Page 8 of 14 Rev. 11 SAT/UNSAT ( ( STEP 7.: [5] RECORD the steady state values for the following: - SAT A. [O-EI-82-34]. DG 1B-B incoming Voltage. B. rO-XI-82-321, DG 1B-B incoming Frequency. - UNSAT C. Time from Stopwatch(es): Seco nds Stopwatch ID Number Seconds Stopwatch 10 Number CUE: Time from stop watch. = 9.48 seconds STANDARD: Operator records parameters as directed and verifies acceptance criteria met. DIG voltage (as indicated on INC Voltage Gen 1B-B 0-EI-34) is;:: 6800 but :s. 7260 volts and frequency (as indicated on INC Freq Gen 1B-B 0-XI-82-32) is ;:: 58.8 Hz and s 61.2 Hz COMMENTS: ACCEPTANCE CRITERIA: DIG 1B-B achieves steady state generator voltage of ;::6800 and ~7260 volts and frequency of ;::58.8 Hz and :s. 61.2 Hz. STEP 8.: [6] RECORD Voltage Regulator Control Current. - SAT Cue: Voltage Regulator Control Current Is 1.8 dc amps. - UNSAT STAN DARD: Operator records Voltage Regulator Control Current. COMM ENTS: ACCEPTANCE CRITERIA: Voltage Regulator Control Current between 1.0 - 2.5 dc amps. The Voltage regulator card must be functioning properly to consider DG operable. STEP 9.: [7] ENSURE DIG 1B*B [86 LOR] red light NOT ILLUMINATED, at DIG local - SAT relay panel. - UNSAT Cue: Role Playas DIG operator - 86 LOR local red light Is not Illuminated. STANDARD Operator request DIG operator to verify red light on 86 LOR at DIG is not illuminated. COMMENTS:

Job Performance Checklist: STEP/STANDARD JPM B.1.b Page 9 of 14 Rev. 11 SATIUNSAT ( ( ( Booth operator: to reset 86LOR, IRF EGR08 f:1 ; then notify operator 86 LOR Is reset. NOTE Do not hold [86 LOR] in RESET position if it does not latch on the first attempt. Coil failure may result if relay is held in RESET position. STEP 10.: [8] RESET [86 LOR] Lockout Relay. on DIG local relay panel. - SAT NOTE: When requested of DIG AUO. reset 86LOR - UNSAT [Booth operator: IRF EGR08 f:1 to reset 86LOR; then notify operator 86 LOR is reset) Critical Step STANDARD: 86 LOR is reset. This step is critical to allow paralleling the D/G to the Shutdown Bd. COMMENTS: STEP 11.: [9] VERIFY [86LOR] is reset by amber light [0-XI-82-49] ILLUMINATED on 0-M-26. STANDARD: 86 LOR amber light on 0-M-26 is verified lit COMMENTS: STEP 12.: [10] IF the D/G-DAQ was used. THEN - SAT RECORD from the time required to achieve :2: 6800 Volts and z 58.8 HZ - UNSAT from the D/G*DAQ computer: Seconds Cue: Time was 9.5 seconds for D/G*DAQ. STANDARD: Operator ensures the DG accelerates to at least 900 rpm (58.8 - 61.2 Hz) and Voltage and frequency are within limit within the required 10 seconds. (Evaluator can sign for Tech Support) COMMENTS:

ACCEPTANCE CRITERIA: D/G lB-B start from ambient condition achieves in less than or equal to 10 seconds generator voltage 2: 58.8 Hz. STEP 13.: [11] RECORD start as ambient in 0-SI*OPS-082-007.M. - SAT Cue: Another operator will record start. - UNSAT STANDARD: Operator logs (addresses logging) the start in 0*SI-OPS-082-007.M. COMMENTS: STEP 14.: [12] RETURN to Section 6.1, Step [9] of this instruction. - SAT STANDARD: Operator returns to the appropriate section and step of the procedure. - UNSAT (Exits Appendix C) COMMENTS: EVALUATOR NOTE: Followina steps evaluate procedure section 6.1. STEP 15.: [9] PERFORM the following to wipe the Automatic Voltage Control Rheostat: - SAT [a] RECORD voltage from [D-EI-82-34]. - UNSAT [b] ENSURE [O-HS-82-42] DG lA-A Voltage Regulator Switch in the PULL-P-AUTO position [c] DECREASE voltage to 6700 volts on [O-EI-82-34) USING [D-HS- 82-42] [d] INCREASE voltage to 7300 volts on [O-EI-82-34] USING [O-HS- 82-42] [e] RETURN voltage to value recorded in [9Ile]. STANDARD: Operator uses 0-HS-82-42 to decrease voltage to 6700 volts and increase voltage to 7300 volts, then return voltage to the value recorded in step [glle]. COMMENTS: c ( ( Job Performance Checklist: STEP/STANDARD JPM B.l.b Page 10 of 14 Rev. 11 SAT/UNSAT

Job Performance Checklist: STEPISTANDARD JPM B.1.b Page 11 of 14 Rev. 11 SAT/UNSAT ( ( STEP 16.: [10] PLACE [D-HS-82-48] , Mode Selector Switch in PARALLEL position. - SAT - UNSAT STANDARD: 0-HS*82-48 rotated to the PARALLEL position. Red light "on" & green light "off". This step is critical to place speed droop circuit in Critical Step service. COMMENTS: STEP 17.: [11] ADJUST [0-HS-82-431. DG 1B-B Speed Control Switch to obtain a - SAT synchroscope indication of slowly rotating in [FAST] direction. - UNSAT STANDARD : Operator adjusts speed control hand switch 0-HS-82-43 such that synchroscope (XI-82-31) is moving slowly in the fast direction (slowly clockwise). COMMENTS: STEP 18.: [12] ENSURE [0-HS-82-42]. DG 1B-B Voltage Regulator Low-Raise Switch in - SAT the PULL-P-AUTO position. AND - UNSAT ADJUST to match incoming voltage with running voltage. STANDARD: Operator ensures HS-82-42 in PULL-P-AUTO and adjusts DIG voltage Critical Step such that incoming voltage (EI-82-34) and running voltage (EI-82-35) are approximately equal. Only the bold portion of this standard is critical. This is critical to match voltage of the DIG with the voltage on the Shutdown Bd. COMMENTS:

Job Performance Checklist: STEP/STANDARD JPM B.l .b Page 12 of 14 Rev. 11 SAT/UNSAT ( ( Booth operator: INSERT the following IMF AN_OV_946 1:2 when operator begins discussing the step to close DIG Bkr. STEP 19.: [13] WHEN the synchroscope DG 1B-B [o-SI-82-31] indicates 12 O'Clock - SAT position, THEN CLOSE breaker [1914] via [l -HS-57-73Aj, 1914 DG lB-B to SO - UNSAT BD lB-B, AND START stopwatch. NOTE: When operator begins discussing the step to close DIG Bkr, insert override IMF AN_OV_946 f:2 . STANDARD: Operator discusses closing DIG 1B*B breaker 191 4, but should stop due to annunciator. COMMENTS: STEP 20.: Respond to annuciator panel 0-M-26B window B-4. - SAT STANDARD: Operator pulls AR 0-M26-B and consults page for window B-4 or TAKES - UNSAT PRUDENT ACTION TO EMERGENCY STOP DIG. COMMENTS: EVALUATOR NOTE: The next Performance Step is from the ARP Corrective Actions. STEP 21.: [1] IF DIG running with no valid accident (blackout or SI) signal present, - SAT THEN, ENSURE DIG shutdown by depressing emergency stop pushbutton 0- - UNSAT HS-82-47A. Cue: If contacted, EDG AUO reports Engine 1 LO Pressure is 15 psig and decreasing. Critical Step STANDARD: Operator initiates action [w ithin 2 minutes] after determining no valid accident signal, lube oil pressure low by depressing emergency stop button for Diesel Generator 1B-B. This step is critical to prevent damage to the D/G due to low lube oil pressure. COMMENTS:

JPM B.1.b Page 13 of 14 Rev. 11 Job Performance Checklist: c STEP 22.: STEP/STANDARD Inform US/SRO of Emergency stop of Diesel Generator 1B-B. US/SRO instructs operator to standby for further instructions. SAT/UNSAT SAT UNSAT STANDARD : Operator informs US/SRO of Emergency stop of Diesel Generator 1B-B. COMMENTS : Stop Time__

FROM : SEQU[ YRH OPERRTOR TRR INING PHONE NO. 423 843 4339 '"pr. 04 2007 02 : OOPM P4 CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK) DIRECTIONTO TRAINEE: I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you. INITI,~L CONDITIONS: Both units are at 100% RTP. All systems are OPERABLE, except for the 1B-B DIG , 0-GO-16 has been completed on all the A train equipment. Maintenance has been completed on the 1B-B DIG and the clearance has been removed. The DIG has-been rolled and Is in standby alignment using 0-80-82-2. The AUO at the DIG building has completed Appendix A of 1-SI-OPS-082-007.B and all parameters are within limits. The Ul Control Room AUO has verified breaker 1934 is removed. SI-166.36 is NOT required. D/G-DAQ has been Installed. Room fire protection is in service. Section 4.0 of 1-SI-OPS-082-007.B is complete. INITIATING CUES: The U1 US/SRO has reviewed the completed work package for the 18-8 DIG, all . that remains is to perform 1-SI-OPS-082-007.B for the PMT. You are an extra unit operator and have been assigned to perform the operability. run of DIG 1B-B per SI-OPS-082-o07.B. The PMT requires the AMBIENT MANUAL START method for testing. Notify the US when the test is complete.

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK) DIRECTION TO TRAINEE: I will explain the initial co nditions, and state the task to be performed. All control room steps shall be perform ed for this JPM, including any required comm unications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned tas k. To indicate that you have completed your assigned task return the handout sheet I provided you. INITIAL CONDITIONS: Both units are at 100% RTP. All systems are OPERABLE, except for the 1B-B DIG , 0-GO-1 6 has been completed on all the A train equipment. Maintenance has been completed on the 1B-B DIG and the clearance has been removed. The DIG has been rolled and is in standby alignment using 0-SO-82-2. The AUO at the DIG building has completed Appendix A of 1-SI-OPS-082-007.B and all parameters are- within limits. The U1 Control Room AUO has verified breaker 1934 is in the Disconnect position. SI-166.36 is NOT required. D/G-DAQ has been installed. Applicable steps of Appendix J, Monitoring the DIG Starting Air System, compl Room fire protection is in service. l'. Section 4.0 of 1-SI-OPS-082-007.B is complete. INITIATING CUES: The U1 US/SRO has reviewed the completed work package for the 1B-B remains is to perform 1-SI-OPS-082*007.B for the PMT. You are an extra unit operator and have been assigned to perform the operability run of DIG 1B-B per SI-OPS-082-007.B. The PMT requires the AMBIENT MANUAL START method for testing. Notify the US when the test is complete. }}