20697-10 (3/30/06)
A CALCULATION
SUMMARY
SHEET (CSS)
AREVA Document Identifier 32-9049384-000 NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY Title ENGINEERING EVALUATION OF INSURGE/OUTSURGE TRANSIENTS PREPARED BY:
REVIEWED BY:
METHOD: Z DETAILED CHECK E0 INDEPENDENT CALCULATION NAME Todd Sorensen NAME Tomas Straka SIGNATURE j,
SIGNATURE TITLE Engineer I DATE
/
TITLE Principal Eng DATE 4 '- e/3 D COST REF.
TM STATEMENT:
CENTER 41324 PAGE(S) 16 REVIEWER INDEPENDENCE NAME B. Djazmati PURPOSE AND
SUMMARY
OF RESULTS:
Purpose (Rev. 000):
This document is a non-proprietary version of AREVA NP Document 32-9045275-001. The proprietary information removed from 32-9045275-001 is indicated by a pair of square brackets " (
)." The geometry and operating condition are Dominion Power proprietary. The purpose of this evaluation is to assess the effect of the insurge and outsurge transients on the Surge Nozzle Structural Weld Overlay (SWOL).
The severity of the insurge/outsurge transients for the Surge Nozzle Structural Weld Overlay requires elastic-plastic analysis.
Since the time required for the elastic-plastic analysis is significant, the analysis cannot be completed before the plant restart.
The purpose of this evaluation is to assess the effect of the insurge and outsurge transients on the North Anna Surge Nozzle Structural Weld Overlay and provide assurance for safe operation of the plant for a limited number of cycles. A complete re-analysis including the insurge and outsurge transients is scheduled to be completed by the end of 2007.
==
Conclusion:==
It is judged that II Heat ups and Cool downs with total of I I cycles of these insurge and outsurge transients are acceptable.
Please note that a detailed ASME Section III code analysis is planned to provide a detailed evaluation of the complete number of cycles by the end of 2007.
THE DOCUMENT CONTAINS ASSUMPTIONS THAT MUST BE VERIFIED PRIOR TO USE ON THE FOLLOWING COMPUTER CODES HAVE BEEN USED IN THIS DOCUMENT:
SAFETY-RELATED WORK CODENERSIONIREV CODENERSION/REV F1 YES Z
NO AREVA NP Inc., an AREVA and Siemens company Page I of 16
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGE/OUT SURGE TRANSIENTS A R EVA DOCNUME BER LANT 32-9049384-000 Noh Anna Units
& 2 NON-PROPRETARY RECORD OF REVISIONS Prepared by:
I. Sorensen Reviewed by: T. Stiuaka Date: 04/2007 Page 2 Date: 04/2007
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGE/OUISURGE TRANSIENTS A R E V A 1OCU
,, N MB,,
m l 2N, 32-9049384-000 Noth Anna Units
& 2N-PROPRIETARY TABLE OF CONTENTS RECORD OF REVISIONS..........................................................................................................
2
- 1. PURPOSE..................................................................................................................
6
- 2. ANALYTICAL METHODOLOGY......................................................................................
6
- 3. KEY ASSUMPTIONS.............................................................................................................
6
- 4. SEVE RITY ASSE SSMIENT OF ADDITIONAL INSURGE/OUTSURGE TRANSIENTS...............................................................................................................................
7
- 5. NOZZLES COMIPARISON.....................................................................................................
7 5.2.1 T ran sien ts..............................................................
....... 1
- 51..2 E xtern al L oads..........
..........................-......... 11 5.3 M A T E R IA L S...................................................
...................... 1
- 6. EVALUATION OF NOZZLE DIFFERENCES................................................................
13
- 7. RESULTS
SUMMARY
/CONCLUSION OF STRESS ANALYSIS.................................
14
- 8. RESULTS
SUMMARY
/CONCLUSION OF FRACTURE MECHANICS..................... 15
- 9. REFERENCES....................................................................................................................
-16 Prepared by:
T. Sorensen Reviewed by: T. Straka Date: 04/2007 Date: 04/2007 Page 3
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGEJOUISURGE TRANSIENTS AR EVA DOCUMIENT NUMBER PANN 32-9049384-000 North Anna Units 1 & 2 NON-PROPRIETARY LIST OF TABLES Table 5.1-1 Geometry Comparison..-.....................
7........-.......
7 Table 5.2-1 Insurge/Outsurge Transient Comparison...........................11 Table 5.2-2 DC Cook Unit I External Loads 12 Table 5.2-3 DC Cook Unit 2 External Loads 12 Table 5.2-4 North Anna External Loads.............
... 12 Table 5.3-1 Material Comparison........................................
13 Prepared by:. I.. Sorensen Reviewed by: T. Straka Date: 04/2007 Date: 04/2007 Page 4
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGE/OUISURGE TRANSIENTS A R EVA DOCUbMEN NUMBER PANITE 32-9049384-000 North Anna Units I & 2 NON-PROPRIETARY LIST OF FIGURES Figure 5.1-1 Figure 5.1-2 Figure 5.1-3 Model ofDC Cook Unit I Smuge Nozzle.............................
8 Model of DC Cook Unit 2 Surge Nozzle.............................9 Model of'North Anna Unit I and 2 Surge Nozzle..
10 Prepared by:
T. Sorensen Reviewed by: T. Straka Date: 04/2007 Date: 04/2007 Page 5
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGFOUTSURGE TRANSIENTS AREVA DOCI NUME PLANON-PROPRIETARY 32-9049384-000 North Anna Units 1 & 2
- 1. PURPOSE The purpose of'this evaluation is to assess the effect of the insurge and outsuige transients on the Surge Nozzle Structural Weld Overlay (SWOL).
Due to severity of the insurge/outsutge transients, the Surge Nozzle Structural Weld Overlay requires elastic-plastic analysis. Since the time required for the elastic-plastic analysis is significant, the analysis cannot be completed before the plant restart-The purpose of this evaluation is to assess the effect of the insurge and outsurge transients on the North Anna Surge Nozzle Structural Weld Overlay and provide assurance for safe operation of' the plant fox a limited number of' cycles. A complete re-analysis including the insurge and outsutge transients is scheduled to be completed by the end of 2007.
- 2.
ANALYTICAL METHODOLOGY The insurge and outsurge transients will only impact the secondary and fatigue criteria and crack growth analysis. The SWOL was sized to meet the requirements of Code Case N-740-1 (Reference 7).
The sizing calculation ensures the SWOL is capable of transferring the loads between the piping and nozzle. Therefore, the SWOL meets all the primary requirements defined by the ASME Code. By definition, the insurge and outsurge transients will not affect the primary stresses and therefore the primary Code requirements are not affected by the addition of these transients The general methodology for the evaluation of the unanalyzed transients on ASME code criteria ate:
- 1) Evaluate the severity of the transients based on temperature and pressure difference between starting and ending time point, flow rates, number of occurrences, temperature gradients and other factor's affecting stresses usage factors and ratcheting.
- 2) If transients are found to be severe, evaluation of their impact on ASME criteria will be performed using comparison to similar surge nozzle geometries subjected to similar loads.
- 3) Reconcile the design and transient differences between the North Anna surge nozzles and the DC Cook nozzles. Nozzle dimensions that impact stresses in the overlaid region ate: nozzle inside diameter, nozzle outside diameter, weld overlay thickness, thermal sleeve thickness and placement, head thickness, head radius. Loads that impact the stresses are transients and external loads..
Finally, materials must be compared for' their physical properties and allowable limits.
- 3.
KEY ASSUMPTIONS There are no major assumptions for this calculation. Minor Assumptions are noted where applicable.
/
Prepared by:
T. Sorensen Date: 04/2007 Page 6 Reviewed by: T. Straka Date: 04/2007
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGE/OUISURGE TRANSIENTS AR EVA DOCUMEN NU*MB*E PN PIn 1
32-9049384-000 North Anna Units 1 & 2 NON-PROPRIETARY
- 4.
SEVERITY ASSESSMENT OF ADDITIONAL INSURGEIOUTSURGE TRANSIENTS Upon review of Reference 1, it was concluded that the additional insuige/outsuige transients ate of' severe nature and would affect secondary stresses, fatigue and possibly other applicable ASME criteria.
- 5.
NOZZLES COMPARISON DC Cook Units 1, 2 surge nozzles were selected because they ae neatly identical to the North Anna Units 1, 2 surge nozzles. The DC Cook surge nozzles were analyzed in detail to the ASME Section HI code and reported in Reference 2 and Reference 3.
5.1 GEOMETRY Ihe following table summarizes key geometrical dimensions of DC Cook Unitl, DC Cook Unit2 and North Anna surge nozzles. Compared ae dimensions that ate significant for stresses..
Table 5.1-1 Geometry Comparison Prepated by:
T. Sorensen Reviewed by: 1. Straka Date: 04/2007 Date: 04/2007 Page 7
NORTH ANNA UNITS l&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENG.INEERING EVALUATION O1F INSURGE/OUTSURGE. TRANSIENTS A R EV DOCUMEN NU.dBEA nP 1
32-9049384-000 North Anna Units I & 2 NON-PROPRIETARY Figure 5.1-1 Model of DC Cook Unit I Surge Nozzle
.i': !
- I T :: *.......
i" "
Prepared by:
I, Soiensen Reviewed by: I. Sthaka Date: 04/2007 Date: 04/2007 Page 8
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGE/OUTSURGE TRANSIENT'S AREVA DOCUME MER ANNON-PROPRETARY 1
1 32-9049384-000 North Anna Units 1 & 2 N
Figure 5.1-2 Model of DC Cook Unit 2 Surge Nozzle Prepared by: r.. Sorensen Reviewed by: I. Straka Date: 04/2007 Date: 04/2007 Page 9
NORTH ANNA UNIT'S l&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGE/OUTSURGE TRANSIENTS AR EVA DOCLUeT*lMhd*
PITIETAR 32-9049384-000 Noith Anna Units I & 2 NON-PROPRIETARY Figure 6.1-3 Model of North Anna Unit 1 and 2 Surge Nozzle Prepared by:
- 1. Sorensen Reviewed by: T. Straka Date: 04/2007 Date: 04/2007 Page 10
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGEIOUTSURGE TRANSIENIS AREVA DOCMI NUMBER ANNON-PROPRIETARY 1
1 32-9049384-000 North Anna Units I & 2 N
5.2 LOADS The following is comparison of loads applied on DC Cook Unit 1, DC Cook Unit 2 and North Anna pressmizer surge nozzles..
5.2.1 Transients The following is a tabulation of'the insuwge/outsurge transients comparison between DC Cook Unit 1, 2 and the North Anna Units 1, 2 pressurizer surge nozzles..
Tam3le 5.2-1 InsurgelOutsurge Transient Comparison 5.2.2 External Loads The following tabulation shows a comparison for the external loads between DC Cook Unit 1, 2 and North Anna Units 1, 2 pressurizer surge nozzle.
Dead Weight (DW) and DBE loads are not considered here. DW does not contribute to the stress intensity ranges. DBE is not considered since it is a Faulted condition load and therefore is not required for the Primazy + Secondry Stress Intensity check and fatigue.......
Prepared by:
T.. Sorensen Reviewed by: T.. Straka Date: 04/2007 Date: 04/2007 Page 11
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUAIION OF INSURGE/OUISURGE TRANSIENTS AR EVA 24 4-0t Anna Units 12 NON-PROPRIETARY 32-9049384-000 Noitla Anna Units I & 2
/I**"-
Table 5.2-2 DC Cook Unit I External Loads Table 5.2-3 DC Cook Unit 2 External Loads J
Table 5.2-4 North Anna External Loads 2
-I Prepaied by:
T. Sorensen Reviewed by: T. Staka Date: 04/2007 Date: 04/2007 Page 12
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGE/OUISURGE TRANSIENTS AREVA DOCUMET NUM PLANTNON-PROPRIETARY 32-9049384-000 North Anna Units I & 2 5.3 MATERIALS Connections of' materials of dissimilar physical properties such as thermal expansion, Young's modulus, specific heat, thermal conductivity and density would affect secondary stresses. In addition, stress allowable limits will affect the ASME criteria.
The following table shows a comparison of the materials used for DC Cook Unit 1, 2 and North Anna Units 1, 2 surge nozzles.
Table 5.3-1 Material Comparison 6.
EVALUATION OF NOZZLE DIFFERENCES
- 1) Geometry: A review of geometrical differences indicates that all three nozzles configurations. ae very similar. Parameters critical for' stresses such as OD and ID at the overlaid region are nearly identical. The only diffeience between North Anna Units 1, 2 and DC Cook Units 1, 2 is at the minimum safe end ID that differs within ( ).. The overlay thicknesses have minor variations.. This will produce an insignificant impact on stresses, and subsequently any crack growth that-may occur.. Other variations are also judged to have negligible effects on stresses.
- 2) Transients:.There is..one similar transient between DC Cook Units 1, 2 and North Anna Units 1, 2.
The insurge/outsurge off. deltaI occurs( htimes for both DC Cook Units.. North Anna experiences Prepared by:
T. Sorensen Reviewed by: T.. Straka Date: 04/2007 Date: 04/2007 Page 13
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF 1NSURGEIOUISURGE TRANSIENTS AR EVA DOCUMEN INUMBER P1 ANT 1
32-9049384-000 North Anna Units 1 & 2 N
RY
( ]occurrences.. This is the most severe and bounding transient fox all the plants. This transient is more severe fox DC Cook Units I and 2 since the average temperature gradient is larger, the pressure change dining instuge/outsuige is significantly higher and finally, the flow rate is significantly higher. Due to these increased severities, DC Cook surge nozzles are expected to experience noticeably higher stresses and its ranges.
- 3) External Loads: There is a wide spread of external loads between each unit, however, there is relatively small contribution of' external loads to stresses and usage factor since during insmuge/outsurge, there is no stratification load. (It must be pointed out that stratification loads have been considered for the North Anna PRZ Surge nozzle analysis, Reference 6). The thermal expansion is assumed to have a small contribution to fatigue and stresses since the insurge/outsurge is a relatively short event (small variation of thermal expansion load) that happens at the beginning of heat up and end of cool down.. Finally, it is very unlikely that OBE will consistently happen during the insurge/outsuige. Therefore, the OBE will not affect stress ranges due to the insurge/outsurge events.
- 4) Materials:
The materials for the head and surge nozzle of North Anna Unit 1 &2 are not the same as at D. C. Cook UI. The difference in Young's modulus is about(
)and the difference in coefficient of thermal expansion is about ( J. It is judged that this difference will cause some impact on stresses, but the impact on stresses and usage is judged to be of low significance that will not invalidate this conservative comparison evaluation. Since the materials for the head and sunge nozzle of'North Anna Unit 1 &2 are the same as for D.. C. Cook U2, the stresses and usage factor are comparable.
The pipe and elbow material for North Anna Units I and 2 is different compared to D. C.. Cook U1 and U2.. However, all the materials are (
3 and the differences in the properties are insignificant.
- 7.
RESULTS
SUMMARY
ICONCLUSION OF STRESS ANALYSIS It is shown that DC Cook Units 1, 2 surge nozzles are comparable to North Anna Units 1, 2 surge nozzles.. Conservative analyses for-DC Cook Units 1 and 2 qualified the overlaid nozzles to all applicable requirements of the ASMIE code as indicated in conclusions of both documents, Reference 2 and Reference 3. It is expected that using the same level of conservatism as for the DC Cook calculations, North Anna surge nozzle analysis would yield lower, or at worst case, comparable results..
The maximum increase of' usage factor for(
I heat up and cool down transients with total(
3 instuge/outsurges pet Reference 3 for DC Cook U2 is T
3 Ihe contribution of the insurge/outsunge as a sub-cycle is(
J. The maximum increase of usage factor prorated forL. heat up and cool down transients with total(
Jinsurge/outsurges per Reference 2 for DC Cook UI is
... I The prorated contribution of the insurge/outsurge as a sub-cycle is (
- 3. The main difference in the usage factor is the level of conservatism. DC Cook U2 was first of'a kind, thus more conservatisms were used. The maximum usage calculated for North Anna surge nozzle without the additional insurge/outsutge transients is [.
per Reference 6. Considering usage factor of ( 3 per Reference 10 of the un-overlaid original nozzle for full amount of design transient cycles to account for cycles spent, it is clear-that the total(
) usage factor will not exceed the allowable limit. In addition, there is
..no.impact on prirmarystress magnitudes and limits..
Prepared by:
T. Sorensen Date: 04/2007 Page 14 Reviewed by: T. Straka Date: 04/2007
NORTH ANNA UNITS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGE/OUI.SURGE TRANSIENTS A R EVA Pxtrni LmE AN AREV DMUENT UMURnAMNON-PROPRIETARY 32-9049384-000 North Anna Units 1 & 2 The above comparison, the small contribution of the insuige/outsurge transients to fatigue, and the low fatigue usage calculated for the North Anna Analysis, provide the justification for accepting a small number of the un-analyzed transients.. Since two insurge/outsurge events are considered for heat ups and two insuige/outsurge events are considered fox cool downs per-Reference 10, conservatively, it is judged that number of plant restart shall be limited t4( I heatups and cooldowns combined with a total of( ) cycles of these insurge/outsurge transients. This number of' events can be imposed on the overlaid pressurizer surge nozzle with no impact to safety of North Anna Units 1, 2 without detailed analyses of these events performed. Please note that a detailed analysis is planned to provide a detailed evaluation of the complete number of cycles by the end of 2007.
- 8.
RESULTS
SUMMARY
ICONCLUSION OF FRACTURE MECHANICS For the limited number-of proposed cycles, ( )heatups and cooldowns combined with( ) cycles of insurge/outsutrge transients), the amount of crack growth is expected to be very small. Based on the fiacture mechanics analyses performed to assess crack growth at the surge nozzles at DC Cook Units 1, 2 (References 8 & 9), thel Iheatups and cooldowns combined with(. cycles of insurge/outsurge transients contributed no more than
') of crack growth. A similar, amount of crack growth is expected at North Anna which is similar to the DC Cook units, as demonstrated by the comparison in Section 6.0. This amount of' ciack growth is much less than the value currently calculated for-the remaining life of the North Anna surge nozzle. The crack growth analysis was performed considering the existence of a postulated flaw. Post-weld overlay NDE inspection of the surge nozzle was performed for the outer
)of the original pipe thickness as per the requirements of ASME Code Case N-740 and no indications were found.. Therefore, for the limited period of time for which this justification is performed, it is assured that the weld overlay thickness is more than adequate to accommodate any potential crack growth due to the heatup/cooldown and insuige/outsurge transients.
Prepared by:
I. Sorensen Reviewed by: T. Straka Date: 04/2007 Date: 04/2007 Page 15
NORTH ANNA UNIIS 1&2, PRESSURIZER SURGE NOZZLE WELD OVERLAY A
ENGINEERING EVALUATION OF INSURGE/OUTSURGE TRANSIENTS AREVA DOCUM NUMBE ANON-PROPRETARY 1_
1 32-9049384-000 North Anna Units 1 & 2 N
- 9.
REFERENCES 1
2 3
4 5
6 7
8 9
10 AREVA Document 38-9034638-002, "Required Engineering Input for North Anna Pressurizer Weld Overlays, North Anna Power Station Units I & 2."
AREVA Document 32-9028843-001, "DC Cook Unit 1 Pressurizer Surge Nozzle Weld Overlay Analysis."
AREVA Document 32-9011982-002, "DC Cook 2 Pressurizer-Surge Nozzle Weld Overlay Analysis."
AREVA Document 32-9022616-005, "DC Cook Unit 1 Pressurizer Nozzle Design Transient."
AREVA Document 32-9015165-000, "Flow in DC Cook Surge Line" AREVA Document 32-9038239-000, "North Anna Units 1&2, Pressurizer Surge Nozzle Weld Overlay Analysis."
AREVA Document 32-9034323-003, "North Anna Units 1&2, Pressurizer Surge Weld Overlay Sizing Calculation-Surge Nozzle."
AREVA Document 32-9012181-001, "DC Cook Unit 2 Pressurizer Surge Nozzle Weld Overlay Crack Growth Evaluation" AREVA Document 32-9028241-000, DC Cook Unit 1 Pressurizer Surge Nozzle Weld Overlay Crack Growth Evaluation."
AREVA Document 38-9046827-000, "Additional Engineering Input for North Anna Pressurizer Surge Nozzle Weld Overlays, North Anna Power Station Units I & 2;"
Prepared by:
T.. Sorensen Reviewed by: I.. Straka Date: 04/2007 Page 16 Date: 04/2007