Response to Generic Letter 2007-01, Inaccessible or Underground Power Cable Failures That Disable Accident Mitigation Systems or Cause Plant Transient
ML071300369
Person / Time
Site: FitzPatrick 
Issue date: 05/02/2007
From: Peter Dietrich
Entergy Nuclear Northeast, Entergy Nuclear Operations
To:
Document Control Desk, NRC/NRR/ADRO
References
GL-07-001, JAFP-07-0059
Download: ML071300369 (2)


Text

SEn tergy Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.

James A. Fitzpatrick N PP P.O. Box 110 Lycoming, NY 13093 Tel 315 349 6024 Fax 315 349 6480 Pete Dietrich Site Vice President - JAF May 2, 2007 JAFP-07-0059 U. S. Nuclear Regulatory Commission Attn: Document Control Desk 11555 Rockville Pike Rockville, Maryland, 20852

REFERENCES:

SUBJECT:

1. NRC Generic Letter 2007-01, "Inaccessible or Underground Power Cable Failures that Disable Accident Mitigation Systems or Cause Plant Transient dated February 7, 2007
2.

NEI letter from J. H. Riley to Administrative Points of Contact, "Guidance for Response to GL 2007-01" dated March 16, 2007

3. NRC Letter from Michael J. Case, to J. H. Riley dated April 13, 2007,:

"Response to Nuclear Energy Institute (NEI) Letter Dated March 26, 2007 -

Re: Interpretation of Generic Letter (GL) 2007-01, Inaccessible or

  • Underground Power Cable Failures that Disable Accident Mitigation Systems or Cause Plant Transients."

RESPONSE TO GENERIC LETTER 2007-01 JAMES A. FITZPATRICK NUCLEAR POWER PLANT DOCKET NO. 50-333, LICENSE NO. DPR-59

Dear Sir or Madam:

Per Reference 1, the NRC issued Generic Letter (GL) 2007-01 to request facilities to submit the following information to the NRC within 90 days of the date of the Generic Letter:

(1) Provide a history of inaccessible or underground power cable failures for all cables that are within the scope of 10 CFR 50.65 (the Maintenance Rule) for all voltage levels. Indicate the type, manufacturer, date of failure, type of service, voltage class, years of service, and the root causes for the failure.

(2) Describe inspection, testing and monitoring programs to detect the degradation of inaccessible or underground power cables that support EDGs, offsite power, ESW, service water, component cooling water and other systems that are within the scope of 10 CFR 50.65 (the Maintenance Rule).

In response to Question 1, JAF used the NEI and NRC guidance provided in References 2 and 3 to clarify the population of cables of interest. The Plant Condition Reporting System (PCRS) data base was researched and knowledgeable engineering, maintenance and operations personnel were

ýA,7

surveyed. To date, JAF has not experienced a cable failure within the scope of the GL. In response to Question 2, JAF inspection, testing, and monitoring practices presently include visual cable inspection during routine maintenance, periodic meggering of cables and connected equipment associated with preventive maintenance activities and periodic inspection of manholes for dewatering. The plant corrective action program is used to determine root cause and extent of conditions where deemed necessary and would be the mechanism for determining the need for and extent of any increased cable monitoring.

No new commitments are identified in this submittal.

If you have any questions or require additional information, please contact Mr. Jim Costedio at 315-349-6358.

The requested information is being provided pursuant the requirements of 10 CFR 50.54(f). I declare under the penalty of perjury that the foregoing information is true and correct. Executed on the A s day of May, 2097.-,,

SITE VICE PRESIDENT PD/cf cc:

Mr. N.B. (Tommy) Le, Senior Project Manager License Renewal Branch B Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 0-11-FlWashington, DC 20555 Mr. Samuel J. Collins, Administrator Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 NRC Resident Inspector U. S. Nuclear Regulatory Commission James A. FitzPatrick Nuclear Power Plant P.O. Box 136 Lycoming, NY 13093 Mr. Paul Eddy New York State Department of Public Service 3 Empire State Plaza, 1 0 th Floor Albany, NY 12223 Mr. Peter R. Smith, President NYSERDA 17 Columbia Circle Albany, NY 12203-6399 Mr. John P. Boska, Project Manager Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop O-8-C2 Washington, DC 20555