Dominion Nuclear Connecticut, Inc.

Millstone Power Station

_.A Dominon-Rope Ferry Road Waterford, CT 06385 MAR 3 0 2007 U. S. Nuclear Regulatory Commission Serial No.

06-731A Attention: Document Control Desk MPS Lic/RWM RO One White Flint North Docket No.

50-423 11555 Rockville Pike License No.

NPF-49 Rockville, Maryland 20852-2738 10 CFR 2.390, Proprietary Information, Enclosure 2 DOMINION NUCLEAR CONNECTICUT, INC.

MILLSTONE POWER STATION UNIT 3 SUPPLEMENTAL INFORMATION REGARDING REQUEST IR-2-47 FOR USE OF WELD OVERLAYS AS AN ALTERNATIVE REPAIR TECHNIQUE This letter provides in enclosure a proprietary and non-proprietary version of the Millstone Power Station Unit 3 weld overlay qualification reports that are associated with a Dominion Nuclear Connecticut, Inc. (DNC) Request IR-2-47.

This supplemental information supports the DNC request for alternative requirements to apply dissimilar metal weld overlays for repair/replacement activities and scheduled preemptive weld overlays in DNC letters dated October 17, 2006, and March 28, 2007. The reports in Enclosures 1 and 2 also satisfy a DNC commitment from the request, dated October 17, 2006, to provide the design information on the weld overlays.

Enclosed are:

1. One copy of WCAP-16734-NP, Rev. 0 "Millstone Unit 3 Pressurizer Safety, Relief, and Surge Nozzles Structural Weld Overlay Qualification," dated March 29, 2007 (Non-Proprietary).
2. One copy of WCAP-16734-P, Rev. 0 "Millstone Unit 3 Pressurizer Safety, Relief, and Surge Nozzles Structural Weld Overlay Qualification," dated March 29, 2007 (Proprietary).

Also enclosed (within Enclosure 2) is a Westinghouse authorization letter CAW-07-2262 with affidavit, Proprietary Information notice, and Copyright Notice. contains information proprietary to Westinghouse Electric Company LLC. It is supported by an affidavit signed by Westinghouse, the owner of the information. The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.390 of the Commission's regulations.

Serial No. 06-731A Docket No. 50-423 Supplemental Information for Request IR-2-47 Page 2 of 2 Accordingly, it is respectfully requested that the information, which is proprietary to Westinghouse, be withheld from public disclosure in accordance with 10 CFR 2.390.

Correspondence with respect to the copyright or proprietary aspects of the items listed above or the supporting Westinghouse affidavit should reference CAW-07-2262 and should be addressed to B. F. Maurer, Acting Manager, Regulatory Compliance and Plant Licensing, Westinghouse Electric Company LLC, P.O. Box 355, Pittsburgh, Pennsylvania 15230-0355.

Should you have any questions about the information provided or require additional information, please contact Mr. David W. Dodson at (860) 447-1791, extension 2346.

Very truly yours, J. I Price SiJtice President-Millstone

Enclosures:

(2)

Commitments: None cc:

U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406-1415.

Mr. V. Nerses Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mail Stop 8C2 Rockville, MD 20852-2738 Mr. S. M. Schneider NRC Senior Resident Inspector Millstone Power Station

Serial No. 06-731A Docket No. 50-423 ENCLOSURE 1 WESTINGHOUSE REPORT WCAP-16734-NP, REV 0 MILLSTONE UNIT 3 PRESSURIZER SAFETY, RELIEF, AND SURGE NOZZLES STRUCTURAL WELD OVERLAY QUALIFICATION (Non-Proprietary)

(92 pages)

MILLSTONE POWER STATION UNIT 3 DOMINION NUCLEAR CONNECTICUT, INC.