April 5, 2007 LICENSEE:

Nuclear Management Company FACILITY:

Point Beach Nuclear Power Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF THE MARCH 28, 2007, PUBLIC MEETING TO DISCUSS THE POINT BEACH END-OF-CYCLE PLANT PERFORMANCE ASSESSMENT On March 28, 2007, the Nuclear Regulatory Commission (NRC) held a public meeting at the Two Creeks Town Hall in Two Creeks, Wisconsin. The meeting was between NRC Region III management and Nuclear Management Company representatives to discuss the NRCs End-of-Cycle Assessment of the Point Beach Nuclear Power Plant's safety performance and the recent decision to return the Point Beach plant to normal NRC oversight. The meeting notice and NRC presentations can be found in the Agencywide Documents Access and Management System (ADAMS) as ML070670191, ML070940318, respectively. A list of principal NRC and licensee meeting participants is attached to this letter.

The NRC began the meeting with an overview of the NRCs Reactor Oversight Program (ROP),

national ROP results, and the Action Matrix in general. This was followed by a discussion of the NRCs assessment of the Point Beach plants performance in calendar year 2006, which was documented in the March 2, 2007, end-of-cycle assessment letter. Following the NRC, the licensee made a brief presentation in response to the NRCs assessment.

Before adjourning the meeting, the NRC provided the opportunity for members of the public to ask questions.

/RA/

Patrick L. Louden, Chief Branch 5 Division of Reactor Projects Docket No. 50-266; 50-301 License No. DPR-24; DPR-27

Attachment:

As Stated DISTRIBUTION:

See next page

LICENSEE:

Nuclear Management Company FACILITY:

Point Beach Nuclear Power Plant, Units 1 and 2

SUBJECT:

SUMMARY

OF THE MARCH 28, 2007, PUBLIC MEETING TO DISCUSS THE POINT BEACH END-OF-CYCLE PLANT PERFORMANCE ASSESSMENT On March 28, 2007, the Nuclear Regulatory Commission (NRC) held a public meeting at the Two Creeks Town Hall in Two Creeks, Wisconsin. The meeting was between NRC Region III management and Nuclear Management Company representatives to discuss the NRCs End-of-Cycle Assessment of the Point Beach Nuclear Power Plant's safety performance and the recent decision to return the Point Beach plant to normal NRC oversight. The meeting notice and NRC presentations can be found in the Agencywide Documents Access and Management System (ADAMS) as ML070670191, ML070940318, respectively. A list of principal NRC and licensee meeting participants is attached to this letter.

The NRC began the meeting with an overview of the NRCs Reactor Oversight Program (ROP),

national ROP results, and the Action Matrix in general. This was followed by a discussion of the NRCs assessment of the Point Beach plants performance in calendar year 2006, which was documented in the March 2, 2007, end-of-cycle assessment letter. Following the NRC, the licensee made a brief presentation in response to the NRCs assessment.

Before adjourning the meeting, the NRC provided the opportunity for members of the public to ask questions.

Patrick L. Louden, Chief Branch 5 Division of Reactor Projects Docket No. 50-266; 50-301 License No. DPR-24; DPR-27

Attachment:

As Stated DISTRIBUTION:

See next page DOCUMENT NAME:C:\\FileNet\\ML070950550.wpd G Publicly Available G Non-Publicly Available G Sensitive G Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy OFFICE RIII NAME PLouden:dtp DATE 04/05/07 OFFICIAL RECORD COPY

Attachment Meeting Participants NRC J. Caldwell, Regional Administrator, RIII M. Satorius, Division Chief, DRP, RIII P. Louden, Branch Chief, DRP, RIII R. Krsek, Senior Resident Inspector, Point Beach G. Gibbs, Resident Inspector, Point Beach P. Milano, Project Manager, NRR K. Barclay, Reactor Engineer, DRP, RIII D. Betancourt-Roldan, Reactor Engineer, DRP, RIII B. Smith, Reactor Engineer, NRR Nuclear Management Company D. Cooper, Chief Nuclear Officer, NMC D. Koehl, Site Vice President J. McCarthy, Director of Site Operations G. Packard, Plant Manager C. Butcher, Engineering Manager

Nuclear Management Company cc w/encl:

Dennis L. Koehl, Site Vice President F. Kuester, President and Chief Executive Officer, We Generation D. Cooper, Senior Vice President and Chief Nuclear Officer J. McCarthy, Site Director of Operations D. Weaver, Nuclear Asset Manager Plant Manager Regulatory Affairs Manager Training Manager Site Assessment Manager Site Engineering Director Emergency Planning Manager J. Rogoff, Vice President, Counsel & Secretary K. Duveneck, Town Chairman Town of Two Creeks Chairperson Public Service Commission of Wisconsin J. Kitsembel, Electric Division Public Service Commission of Wisconsin State Liaison Officer Chairman, Manitowoc County Board County Executive, Manitowoc Director, Manitowac County Emergency Management Agency Chairman, Kewaunee County Board Mayor of Kewaunee City Manager, Two Rivers Director, Kewaunee County Emergency Management Agency President, Village of Mishicot Chairman, Village of Two Creeks INPO

Nuclear Management Company DISTRIBUTION:

EMH1 LXR1 CFL JLD RidsNrrDirslpab JLC1 GEG KGO GLS RML2 SAM9 SRI Point Beach DRPIII DRSIII PLB1 TXN