March 13, 2007 MEMORANDUM TO: Dave Terao, Chief Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM: Allen G. Howe, Chief /RA/

Instrumentation and Controls Branch Division of Engineering Office of Nuclear Reactor Regulation

SUBJECT:

INACCURACY IN RESPONSE TO THE REQUEST FOR ADDITIONAL REGARDING CREDITING SERVICE WATER FOR REACTOR EQUIPMENT COOLING POST LOSS-OF-COOLANT ACCIDENT (TAC NO. MD3545) - COOPER NUCLEAR STATION The Instrumentation and Control Branch has reviewed the information provided by the licensee (ML0629101560) pertaining to inaccuracy in response to the request for additional information regarding crediting service water for reactor equipment cooling post loss-of-coolant accident at Cooper Nuclear Station, and finds that this inaccurate response did not impact our conclusion in the corresponding safety evaluation report (ML0107402200).

CONTACT: Deanna Zhang, NRO/DE/ICE1 (301)415-1946

March 13, 2007 MEMORANDUM TO: Dave Terao, Chief Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM: Allen G. Howe, Chief /RA/

Instrumentation and Controls Branch Division of Engineering Office of Nuclear Reactor Regulation

SUBJECT:

INACCURACY IN RESPONSE TO THE REQUEST FOR ADDITIONAL REGARDING CREDITING SERVICE WATER FOR REACTOR EQUIPMENT COOLING POST LOSS-OF-COOLANT ACCIDENT (TAC NO. MD3545) - COOPER NUCLEAR STATION The Instrumentation and Control Branch has reviewed the information provided by the licensee (ML0629101560) pertaining to inaccuracy in response to the request for additional information regarding crediting service water for reactor equipment cooling post loss-of-coolant accident at Cooper Nuclear Station, and finds that this inaccurate response did not impact our conclusion in the corresponding safety evaluation report (ML0107402200).

Docket No.: 50-298

Enclosure:

As stated DISTRIBUTION:

EICB R/F HGarg AHowe DZhang NRR_DE_DPR ADAMS/ACCESSION NO:

OFFICE ICE1:DE:NRO EICB:DE:NRR BC:EICB:NRR NAME DZhang PRebstock AHowe DATE 3/13 /07 3/13 /07 3/13 /07 OFFICIAL RECORDS COPY