From:

"Mogolesko, Fred" <fmogole@entergy.com>

To:

"Glenn Meyer" <GWM@nrc.gov>

Date:

08/24/2006 1:50:48 PM

Subject:

RE: Pilgrim AMP Review Glen:

We will be forwarding four products for your use:

1. LRPD-02: Aging Management Program Evaluation Report (will be updated by the time your team arrives. There are minor updates being developed since we treat all reports as living documents).
2. LR Audit Database for Aging Management Programs (Q&A).
3. Training Material for Aging Management Programs (used in-house).
4. Pilgrim's License Renewal and Inspection Handbook (also under minor revision)

As you can imagine, sending this by email just won't work. Hence, we will soon forward a CD to your office.

Please advise when you receive our package.

Thanks---Fred


Original Message-----

From: Glenn Meyer [1]

Sent: Thursday, August 24, 2006 1:22 PM To: Mogolesko, Fred

Subject:

Re: Pilgrim AMP Review Fred - Yes, those documents seem worthwhile to send electronically.

Anything useful in the comprehensive system listing category? The LRA has systems listed but not to the level of detail that I've seen previously. Is there any other listing?

Typically, there are manuals listing the various aspects of the how the

AMPs address each system. The material can be considerable and binders of material are pulled together to address this area. Does such information exist for Pilgrim? (I realize it might not be available electronically.

Glenn

>>> "Mogolesko, Fred" <fmogole@entergy.com> 08/22/2006 7:35 AM >>>

I have some thoughts based on our conversation of yesterday. We have developed a report: LRPD-02-Aging Management Program Evaluation Report that fed into the LRA that you are reviewing. For each program we discuss the 10 attributes from NUREG-1800, Appendix A, Table A.1-1.

After discussing each attribute, a Summary is presented and compliance with the governing expectation is stated and exceptions/enhancements are also identified.

The report identifies new programs or activities credited, existing programs or activities credited, and includes attachments for one-time inspection activities, periodic surveillance and preventative maintenance activities, structures monitoring program general criteria, and PNPS response to BWRVIP applicant action items.

We also have a training module for our staff defining the aging management program. Lastly, we have a License Renewal Inspection Handbook where each system within the scope for aging management is identified with an owner.

I wonder whether forwarding these documents electronically would be beneficial. Please advise.

Fred CC:

"Brochu, Jill" <JBroc94@entergy.com>, "Mogolesko, Fred"

<fmogole@entergy.com>

Mail Envelope Properties (44EDE6E1.597 : 1 : 9623)

Subject:

RE: Pilgrim AMP Review Creation Date 08/24/2006 1:50:08 PM From:

"Mogolesko, Fred" <fmogole@entergy.com>

Created By:

fmogole@entergy.com Recipients nrc.gov kp1_po.KP_DO GWM (Glenn Meyer) entergy.com JBroc94 CC (Jill Brochu)

Post Office Route kp1_po.KP_DO nrc.gov entergy.com Files Size Date & Time MESSAGE 2584 08/24/2006 1:50:08 PM TEXT.htm 10581 Mime.822 16474 Options Expiration Date:

None Priority:

Standard ReplyRequested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard Junk Mail Handling Evaluation Results Message is eligible for Junk Mail handling This message was not classified as Junk Mail Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled