UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 475 ALLENDALE ROAD KING OF PRUSSIA, PENNSYLVANIA 19406-1415 March 2, 2007 Mrs. Mary G. Korsnick Vice President R. E. Ginna Nuclear Power Plant R. E. Ginna Nuclear Power Plant, LLC 1503 Lake Road Ontario, NY 14519

SUBJECT:

ANNUAL ASSESSMENT LETTER - R. E. GINNA NUCLEAR POWER PLANT (REPORT 05000244/2007001)

Dear Mrs. Korsnick:

On February 12, 2007, the NRC staff completed its performance review of R. E. Ginna Nuclear Power Plant (Ginna). Our technical staff reviewed performance indicators (PIs) for the most recent quarter and inspection results for the period from January 1 through December 31, 2006.

The purpose of this letter is to inform you of our assessment of your safety performance during this period and our plans for future inspections at your facility.

This performance review and enclosed inspection plan do not include physical protection information. A separate letter designated and marked as "Exempt from Public Disclosure in accordance with 10 CFR 2.390" will include the physical protection review and resultant inspection plan.

Overall, Ginna operated in a manner that preserved public health and safety and fully met all cornerstone objectives. Plant performance for the most recent quarter, as well as for the first three quarters of the assessment cycle, was within the Licensee Response column of the NRCs Action Matrix, based on all inspection findings being classified as having very low safety significance (Green) and all PIs indicating performance at a level requiring no additional NRC oversight (Green). Therefore, we plan to conduct reactor oversight process (ROP) baseline inspections at your facility. We also plan to conduct an additional ROP inspection based on your planned containment sump modification.

The enclosed inspection plan details the inspections, less those related to physical protection, scheduled through June 30, 2008. The inspection plan is provided to allow for the resolution of any scheduling conflicts and personnel availability issues well in advance of inspector arrival onsite. Routine resident inspections are not listed due to their ongoing and continuous nature.

The inspections in the last nine months of the inspection plan are tentative and may be revised at the mid-cycle review.

In accordance with 10 CFR 2.390 of the NRCs "Rules of Practice," a copy of this letter and its enclosure will be made available electronically for public inspection in the NRC Public

2 M. Korsnick Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

If circumstances arise which cause us to change this inspection plan, we will contact you to discuss the change as soon as possible. Please contact me at 610-337-5233 with any questions you may have regarding this letter or the inspection plan.

Sincerely,

/RA/

Brian J. McDermott, Chief Projects Branch 1 Division of Reactor Projects Docket Nos. 50-244 License Nos. DPR-18

Enclosure:

Ginna Inspection / Activity Plan cc w/encl:

M. J. Wallace, President, Constellation Generation J. M. Heffley, Senior Vice President and Chief Nuclear Officer P. Eddy, Electric Division, NYS Department of Public Service C. Donaldson, Esquire, Assistant Attorney General, New York Department of Law C. W. Fleming, Esquire, Senior Counsel, Constellation Energy Group, Inc.

P. R. Smith, New York State Energy Research and Development Authority J. Spath, SLO Designee New York State Energy Research and Development Authority T. Wideman, Director, Wayne County Emergency Management Office M. Meisenzahl, Administrator, Monroe County, Office of Emergency Preparedness T. Judson, Central New York Citizens Awareness Network

Ginna Inspection / Activity Plan 01/01/2007 - 06/30/2008 Inspection Type Inspection Activity Planned Dates Start End No. of Staff on Site Title Unit Number Page 1 of 2 03/01/2007 13:19:10 Report 22 4

7111111B

- LO REQUAL. PROG. + P/F REVIEW Baseline Inspections 01/22/2007 01/26/2007 1

7111111B IP Licensed Operator Requalification Program Baseline Inspections 01/29/2007 02/02/2007 1

7111111B IP Licensed Operator Requalification Program 1

7112101

- OCC RAD SAFETY -ACCESS Baseline Inspections 04/09/2007 04/13/2007 1

7112101 IP Access Control to Radiologically Significant Areas 2

08/27 EX

- OPERATOR LICENSING INITIAL EXAMS Not Applicable 08/06/2007 08/10/2007 1

U01600 GINNA INITIAL EXAM (2/07)

Not Applicable 08/27/2007 08/31/2007 1

U01600 GINNA INITIAL EXAM (2/07) 7 7111401

- EP EXERCISE & PI VERIFICATION Baseline Inspections 05/21/2007 05/25/2007 1

7111401 IP Exercise Evaluation Baseline Inspections 05/21/2007 05/25/2007 1

71151-EP01 IP Drill/Exercise Performance Baseline Inspections 05/21/2007 05/25/2007 1

71151-EP02 IP ERO Drill Participation Baseline Inspections 05/21/2007 05/25/2007 1

71151-EP03 IP Alert & Notification System 1

7112201

- PUB RAD SAFETY - RETS Baseline Inspections 06/18/2007 06/22/2007 1

7112201 IP Radioactive Gaseous and Liquid Effluent Treatment and Monitoring Systems 1

7112103

- OCC RAD SAFETY - INSTR Baseline Inspections 07/23/2007 07/27/2007 1

7112103 IP Radiation Monitoring Instrumentation and Protective Equipment 6

7111121

- CDBI Baseline Inspections 08/13/2007 08/17/2007 1

7111121 IP Component Design Bases Inspection Baseline Inspections 08/27/2007 08/31/2007 1

7111121 IP Component Design Bases Inspection Baseline Inspections 09/10/2007 09/14/2007 1

7111121 IP Component Design Bases Inspection Baseline Inspections 09/17/2007 09/21/2007 1

7111121 IP Component Design Bases Inspection 1

71121

- OCC RAD SAFETY Baseline Inspections 12/17/2007 12/21/2007 1

7112101 IP Access Control to Radiologically Significant Areas Baseline Inspections 12/17/2007 12/21/2007 1

71151 IP Performance Indicator Verification 1

71121

- OCC RAD SAFETY Baseline Inspections 02/11/2008 02/15/2008 1

7112101 IP Access Control to Radiologically Significant Areas Baseline Inspections 02/11/2008 02/15/2008 1

7112102 IP ALARA Planning and Controls Baseline Inspections 02/11/2008 02/15/2008 1

7112103 IP Radiation Monitoring Instrumentation and Protective Equipment Baseline Inspections 02/11/2008 02/15/2008 1

71151 IP Performance Indicator Verification 1

71121

- OCC RAD SAFETY Baseline Inspections 03/31/2008 04/04/2008 1

7112101 IP Access Control to Radiologically Significant Areas Baseline Inspections 03/31/2008 04/04/2008 1

7112102 IP ALARA Planning and Controls Baseline Inspections 03/31/2008 04/04/2008 1

7112103 IP Radiation Monitoring Instrumentation and Protective Equipment Baseline Inspections 03/31/2008 04/04/2008 1

71151 IP Performance Indicator Verification This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Ginna Inspection / Activity Plan 01/01/2007 - 06/30/2008 Inspection Type Inspection Activity Planned Dates Start End No. of Staff on Site Title Unit Number Page 2 of 2 03/01/2007 13:19:10 Report 22 1

7111108P

- INSERVICE INSPECTION Baseline Inspections 04/21/2008 04/25/2008 1

7111108P IP Inservice Inspection Activities - PWR Baseline Inspections 04/28/2008 05/02/2008 1

7111108P IP Inservice Inspection Activities - PWR 1

TI-166

- CONTAINMENT SUMP MODIFICATIONS Safety Issues 04/28/2008 05/02/2008 1

2515/166 IP Pressurized Water Reactor Containment Sump Blockage [NRC GENERIC LETTER 2004-02]

1 71111.12

- MAINTENANCE RULE Baseline Inspections 05/12/2008 05/16/2008 1

7111112B IP Maintenance Effectiveness 3

MODS

- MODS AND 50.59 Baseline Inspections 06/16/2008 06/20/2008 1

7111102 IP Evaluation of Changes, Tests, or Experiments Baseline Inspections 06/16/2008 06/20/2008 1

7111117B IP Permanent Plant Modifications This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

2 M. Korsnick Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

If circumstances arise which cause us to change this inspection plan, we will contact you to discuss the change as soon as possible. Please contact me at 610-337-5233 with any questions you may have regarding this letter or the inspection plan.

Sincerely,

/RA/

Brian J. McDermott, Chief Projects Branch 1 Division of Reactor Projects Docket Nos. 50-244 License Nos. DPR-18

Enclosure:

Ginna Inspection / Activity Plan cc w/encl:

M. J. Wallace, President, Constellation Generation J. M. Heffley, Senior Vice President and Chief Nuclear Officer P. Eddy, Electric Division, NYS Department of Public Service C. Donaldson, Esquire, Assistant Attorney General, New York Department of Law C. W. Fleming, Esquire, Senior Counsel, Constellation Energy Group, Inc.

P. R. Smith, New York State Energy Research and Development Authority J. Spath, SLO Designee New York State Energy Research and Development Authority T. Wideman, Director, Wayne County Emergency Management Office M. Meisenzahl, Administrator, Monroe County, Office of Emergency Preparedness T. Judson, Central New York Citizens Awareness Network Distribution w/encl:

S. Collins, RA M. Dapas, DRA B. Sosa, RI EDO Coordinator B. McDermott, DRP B. Fuller, DRP M. Kowal, NRR D. Pickett, PM, NRR M. David, PM, NRR (Backup)

K. Kolaczyk, DRP, Senior Resident Inspector M. Marshfield, DRP, Resident Inspector K. Kolek, DRP, Resident OA Region I Docket Room (with concurrences)

RidsNrrDirsIpab@nrc.gov Institute of Nuclear Power Operations (INPO)

DOCUMENT NAME: S:\\ROP-7 EOC Review\\2006 ROP-7 Annual Assessment Letters\\PDF Merged files\\Annual Assessment Letter Ginna.wpd SUNSI Review Complete: BJM (Reviewers Initials)

After declaring this document An Official Agency Record it will/be released to the Public.

To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RI/DRP RI/DRP NAME BFuller BMcDermott DATE 03/01/07 03/ 01/07 OFFICIAL RECORD COPY