ML070530154

From kanterella
Jump to navigation Jump to search
Journal of the Hydraulics Division, Unsteady Flow Simulation in Rivers and Reservoirs
ML070530154
Person / Time
Site: Sequoyah  
Issue date: 09/30/1969
From: Garrison J, Granju J, Price J
American Society of Civil Engineers, Tennessee Valley Authority
To:
US Atomic Energy Commission (AEC)
References
Download: ML070530154 (18)


Text

6771 September, 1969 HY 5 Journal of the HYDRAULICS DIVISION Proceedings of the American Society of Civil Engineers By Jack M. Garrison,' M, ASCE, Jean-Pierre P. Granju,'

A. M. ASCE, and James T. P r i ~ e, ~

M. ASCE INTRODUCTION Most mathematical modeling of unsteady flow phenomena has been limited to prismatic channels and somewhat idealized conditions. The Tennessee Valley Authority (TVA) using the numerical methods developed by Stoker (lo),' has successfully applied t h e m to a number of complex unsteady flow conditions whichhave occurred or are expected t~ occur in some of the Authority's rek-ervoirs and natural river channels.

Usingthe varying geometry of these rivers and reservoirs at finite stations located from 0.3 miles to 2.3 miles apart and iteration periods of from 18 sec t o 3 min, accuracies of from 0.1 ft to 0.3 it in stage for depths ranging from 10 ft to 100 ft have been obtained. Computed velocities have checked measured quantities closely over a velocity range of - 0.5 fps to + 5.0 fps.

The results show the advantages and applicability of the digital computer over quasisteady flow methods of handling unsteady flow problems, Also pointed out are areas in the mathematical m d e l in which difficulties have been en-countered along with the methods required to overcome them. These are de-scribed to assist others in using the model.

Prior to the advent of the digital computer, the complexities introduced by attemptingtodetermine flow conditions from unsteady flow principles were so severe that steady or quasisteady flaw methods had to be used. Although the steady flow approach, in many cases, produced valuable and usable results Note.-Discussion open until February 1,1970. To ex$end the closing date one month, a written request must be filed with the Executive Secretary. ASCE. This paper is part of the copyrighted Journal of the Hydraulics Division, Proceedings of the American Society of Civil Engineers, Vol. 95, Eo-HY5, September, 1969. Manuscript was sub-mitted for review for possible publication on September 17, 1968.

a Presented at the August 21-23. 1968, ASCE Hydraulics Division Specialty Con-ference, held at Cambridge, Mass.

'Hydraulic Specialist, Flood Control Branch, TVA, Knoxville, Tenn.

Hydraulic Specialist, Flood Control Branch. TVA, Knoxville, Tenn.

?Hydraulic Specialist. Flood Control Branch, TVA, Knoxville, Tenn.

4Numerals in parentheses refer to corresponding itenls in the Appendix 1.-

References.

1560 September, 1969 HY 5 when tempered with sound engineering judgment, the steady flow approach has often been inadequate because important transient effects cannot be directly determined. For example, flow reversals in a reservoir created by hydroplant operations at one or both ends of the reservoir cannot be determined from steady flow principles. Also, the steady flow approach has led to a number of popular misconceptions about actual flows in real systems, involving such things as downstream flows under upstream sloping water surfaces, upstream flows under downstream sloping water surfaces, flow reversals, wave travel vs. water travel, and water movements induced by passage of long waves.

Great progress has been made in using unsteady ffoiir principles to deter-mine transient flow conditions in reservoirs and rivers with the digital com-puter (1,2,6,7,11). The state of the art has now reached the point where mean velocity, discharge and depth variations can be accurately predicted at any point along a stream or reservoir, given appropriate boundary and initial con-ditions. As a consequence, many conditions of flow previously poorly under-stood or even thought unrealistic are now understood and can be physically explained.

A digital computer program for solving the basic equations of unsteady flows in reservoirs and natural rivers is now being used by the TVA to solve a variety of open-channel flow problems. The program, which has been supported by field measurements, has recently been used: (1) To investigate flow conditions at the cooling water facilities of a nuclear power plant to be located along the Wheeler Reservoir resulting from hydroplant operations at both ends of the reservoir (3); (2) to determine velocity and stage variations in a narrow winding river below an existing hydroelectric station used for power peaking operations; (3) to determine the time-space variations in discharge, velocity, and water surface elevationin a reservoir subjected to operations of a proposed pumped-storage plant; (4) to determine unsteady flow conditions in a system of two large reservoirs connected by a 1.2-mile long navigable canal; and (5) to in-vestigate the passage of a flood wave through a possible future reservoir. Com-puter results and field measurements were in remarkable agreement in the three cases where fielddata were taken, including reverse flows in two reser-voirs and in the canal and locking operations in one of the river reaches.

Results from these studies are described herein.

SUMMARY

OF MATHEMATICAL MODEL The mathematical model for unsteady flows in open channels is assumed to be one-dimensional in the sense that the flow characteristics such as depth and velocity a r e considered to vary only in the longitudinal ( x ) direction and with time. The channel geometry is three-dimensional.

The two equations of unsteady flow, the continuity equation and the equation of motion, (as used in Ref. 9) a r e in which A = flow area; V = mean velocity; x = distance; B = surface width;

HY 5 UNSTEADY FLOW SIMULATION 1561 h = water surface elevation; I = time; y = laterallocal inflow per unit dis-tance and time; g = the gravitational constant; and Sf = the energy gradient given by in which n = Manning's resistance coefficient and R = the hydraulic radius.

The terms aA/ax in the expanded form of Eq. 1 can be expressed a s a function of ah/ax. Therefore, these equations make up a system of two nonlinear, first order, first degree partial differential equations with two independent vari-ables x and t, and with two unknowns h and V. No analytical solutions to this system of equations exist. They may be solved numerically, however, by writing them in finite difference form for digitial computer manipulation.

The boundary conditions may be given a s discharge or water surface ele-vation versus time, or as a stage-discharge relationship. A steady-flow pro-file, a flat pool-zero flow profile or a transient flow profile from previous computations may be used as the initial conditions.

In addition to boundary and initial conditions, input data on local inflows, channel geometry, and boundary resistance must be prescribed. From these inputdata the computer determines flows, mean velocities, and water surface elevationsat any number of desired locations and times for the channel reach under study.

In finite difference methods the differential equation is replaced by an ap-proximating difference equation, and the continuous region in which the solution isdesiredis replaced by a set of discrete points called a net. A variety of net schemes for approximating the differential equations of unsteady flow have been studied by various investigators (6,7,10).

A characteristic computation net has several apparent advantages over other schemes, particularly in the sta-bility and convergence of the solution and in optimization of net size. However, this computation scheme has the disadvantage that the net of points in the x-t plane is determined a s the computation proceeds. It is therefore necessary to compute x and tin addition to h and B, and to use an interpolation procedure if it isdesired to obtain results a t regular or specific distance and time intervals.

The main advantage of fixed net schemes is that the net of points in the x-l plane can be selected prior to computation, so that only h and V need to be computed. The major disadvantage of most explicit fixed-net computation schemes is the difficulty in finding a net size that will give a stable and con-vergent solution. Based on basic studies of many different e-uplicit fixed-net schemes, acentereddifference scheme proposed by Stoker (10) was found suf-ficiently stable and convergent for the unsteady flow computations if the re-lation i s satisfied, in which A t = the time interval and Ax = the distance interval (8). This scheme i s now (1969) being used to compute transient flows.

Flows, stages or rating curves a r e prescribed at the upstream or down-stream boundaries by means of tables. Rating curves are most successfully applied when a downstream control exists, i.e,, a pool, weir, or other device.

They may also be used without a downstream control; however, the rating Is only an approximation in this case because of the unknown loop nature of the

1562 September, 1969 HY 5 actual curve. Off-channel storage in a reach is accounted for in the mathe-matical model by adjusting width B in the equation of continuity to give the correct volume in the reach, Storage width is, generally, different from the flow width upon which the hydraulic radius is based. Channel geometry data TABLE I. -TYPICAL COMPUTING TIME REQUIREMENTS FOR THE TVX PROGR-01 Project or study Number of cross sections (5) 37 23 57 52 5

29 Raccoon Computer range, in day of routing, in minutes Time intervd At, in seconds Mountain Cumber land River Barkley Reservoir Barkley Canal Columbia FIG. 1.-LOCATION M A P OF TVA PROJECTS are determined from interpolptions from tabular values of area, (hydraulic radius)'@, and storage width us. water surface elevation for each station.

Tributary inflows are distributed over a reach of length Ax. This causes no problems because flow conditions near a junction can be studied in sufficient Distilrtce

interval, As, in miles 9 0 6 0 180 15 90 Number of re"ches 2.1 0.5 2.3 0.3 2.0 22 56 5 1 4

28

HY 5 UNSTEADY FLOW SIMULATION 1563 detail by reducing A x in successive runs. An IBM System/360, model 50, or i !

an equivalent system is required to accommcdate the program. Typical com-i '

puting time requirements for the program are given in Table I. The location I

of the projects in Table 1 are shown in Fig. 1.

APPLICATIONS Brozum Fervy Study.-The transient flow conditions in the Wheeler Reser-voir are caused primarily by the intermittent hydropower operations of the I

turbines located at the upstream and downstream boundaries of the reservoir.

Water required for condenser cooling purposes at the Browns Ferry Nuclear FIG. 2--TYPICAL RESULTS FOR BROWNS f ERRY STUDY generating plant now under construction along the Wheeler reservoir will be withdrawn from and returned with an elevated temperature to this reservoir in which flow conditions are continuously changing. These cooling water facil-ities must therefore be so designed as to meet the established water quality standards for the area and to prevent recircuhtion of these heated waters back through the cooling system. Consequently, a thorough knowledge of the Wheeler Reservoir transient flow conditions is one basic need for effective design of these cooling water facilities.

To achieve this basic understanding of the Wheeler Reservoir transients, two paths of endeavor were undertaken almost simultaneously: (1) A mathe-matical model of the Wheeler Reservoir was constructed; and (2) field mea-

FIG. 3.-FLOW CONDITIONS A T FIG. 4.-FLOW CONDITIONS AT BROWNS FIG. 5.-FLOW CONDITIONS A T BROWNS BROWNS FERRY DUE TO PULSE FERRY DUE TO PULSE FLOW UPSTREAPII FERRY DUE TO MODIFIED PULSE FLOW FLOW AT UPSTREAX1 END OF AND STEADY FLOW D0WNSTRE:AM UPSTREAM AND STEADY FLOW DOWN-WHEELER RESERVOIR STREAhhl

HY 5 UNSTEADY FLOW SIMULATION 1565 surements of velocity and stage were undertaken at the plant site beginning September 20, 1966, Using the actual turbine discharges of the Guntersville and Wheeler tur-bines as boundary conditions along with the known reservoir profile as the initial conditions, the equations of the mathematical model were solved on the computer. The calculated velocities and elevations in the reservoir at the plant site, as well as the upstream anddownstream turbine releases producing these changes for a 6-day portion of thefield measurement period, are shown in Fig. 2. These are compared with the actual velocities and elevations mea-sured at the site during the field tests. The elevations match perfectly, The calculated average velocities for the entire cross section are reasonably close to the measured average velocity taken along a single vertical location within this section. By successfully reproducing known reservoir transient conditions, the mathematical model was verified and couldthenbe used with confidence to obtain the transient flow conditions accompanying any set of boundary conditions.

Applications of the calibrated mathematical model used in this manner are demonstrated in Figs. 3 through 5.

Initial conditions used to obtain the computed results in these figures were a flat reservoir pool at El. 555 and zero flow everywhere. The figures show computed flows and velocities at Browns Ferry site for three different sets of boundary flow conditions at Guntersville and Wheeler. Computed variations in water surface elevations at Guntersville, Browns Ferry, and Wheeler are also shownin the figures. Elevations at Browns Ferry and Wheeler are essen-tially the same in the flat section of the reservoir. In Fig. 3 the boundary con-ditions consist of aperiodic pulse flowat Guntersville and zero flow at Wheeler.

The influence of the shutoff at Guntersville on flow conditions at Browns Ferry is shown. The Guntersville influence has been established as the primary cause of flow reversals at the Browns Ferry site such as the one shown in the diagram.

In Fig. 4 the boundary conditions consist ofthe same periodic pulse flow at Guntersville but with a steady flow at Wheeler. It can be seen that this steady outflow at Wheeler is not sufficient to fully counteract the flow reversal re-sultingfrom the Guntersville shutdown. In Fig. 5 the boundary conditions con-sist of a modified Guntersville periodic pulse flow and steady flow at Wheeler.

In this case, the Wheeler steady flow is sufficient to overcome the reduced Guntersville shutoff effect. Using the model in this fashion, sets of operating boundary conditions can be found which will produce satisfactory flow con-ditions at the plant site.

CumBerla7zd River Below Barkley Dnnz. -Stage measurements in reservoirs and rivers can be made with sufficient accuracy by means of mechanical re-cording devices. However, accurate measurements of velocity and discharge are difficult and expensive to make. Todate no economical or practical system exists for making simultaneous and continuous measurements of velocity at a number of points. This is where a mathematical model capable of computing stage, velocity, and discharge at any time and location can be used to great advantage to complement and extend field measurements. Such a use is demonstrated by the f ullowing e-ample. Navigation on the Cumberland River from Barkley Dam to the Ohio River sometimes experiences difficulty in ne-gotiating this narrow, winding channel. This i s particularly true when the Ohio River is at low stage and power peaking operations a r e being conducted at the Barkley project. The river in this reach is about 500ft wide, loft to 40 ftdeep, and follows an irregular and winding path (see Fig. 6). The Corps of Engineers, as a first step in finding a solution to this problem, decided to conduct a series

1566 September, 1969 HY 5 of field test at specific locations ina28-mile reach b l o w Barkley. The tests, made in August, 1967, were a cooperative effort among the Corps, USGS, and TVA. In these tests, a number of different turbine operating patterns were scheduled at Barkley, and during these scheduled releases measurements were made in the study reach to ascertain the flow conditions. Measurements of velocity and stage were taken at selected stations in the reach. Velocity mea-AUGUSl 28.1961 AUGUST 24.1967 AUGUST 30.1967 AUGUST 31.1961 FIG. 6.-TYPICAL STAGE RESULTS FOR CUMBERLAND RIVER BELOW BARKLEY DAM STUDY surements were taken at depths of 0.5 ft, 4.0 ft, 7.5 ft, and 11.0 f t at midstream to define the velocity in the navigation channel. Stage was automatically re-corded at each selected station.

Prior to the field tests, a mathematical model of the river reach using hown stages at permanent gage locations and the corresponding discharges

HY 5 UNSTEADY FLOW SIMVLATION 1567 from Barkley Dam and stage at gage 28 miles down the rivers, had been estab-lished. Then, by prescribing the turbine operations scheduled for the tests and the estimated stage at the downstream end of the reach, the variations in stage, velocity and discharge at the selected stations were predicted using the computer model. The results permitted the field crews to know in advance when velocity and stage changes would occur at measuring stations and, therefore, when to make their measurements. After the tests were completed, comparisons were made between the measured and predicted values of stage COMPUTED MEAN vilOClTY

. :. NAVlGAT.TK?F: CHANNEL YEWCITY OBSfRYATiON hUG 29 Me?

AUG 30 FIG. 7.-TYPICAL VELOCITY RESULTS FOR CUMBERLAND RIVER BELOW BARK-LEY DAM STUDY and velocity. Although the actual turbine discharge and estimated downstream stage were slightly different from the values usedin the prediction, there was still good agreement between observed and predicted values. Timing of stage and velocity agreed perfectly with the predictions. The magnitude of the measured velocities was slightly higher than the predictedvalues, because the measured quantities were discrete values measured in the upper central re-gion of the navigation channel, while the predicted values were mean values for the cross section.

1568 September, 1969 HY 5 After completion of the tests the actual conditions that occurred during the tests were programmed to check the calibration of the model. Even the dis-charges due to lock operations at Barkley Dam were included. The comparison between the computations and measurements was excellent, as shown in Fig. 6.

The computed stage is generally within 0.1 f t of the observed one; and timing of all events, including lockages, agrees perfectly. The velocity comparison is shown in Fig, 7.

Raccoon Mountain Pumped Stovuge Strtdy.--The T V A is studying a pumped storage project, the intake-outlet structure of which would be located on the navigable Nickajack Reservoir at Tennessee River mile444.6. At this location the reservoir is narrow and sinuous. The purpose of this study is to determine the effect of pumped withdrawals and turbine releases on stages and velo-cities in the vicinity of the intake-outlet siructure.

The use of the mat'nematical model for this study is straightforward and, PRLSCRIBLO PUMP-NRBfNE FLOW

. 7 INITIAL AVERAG VELOCITY (I MILE 05)

-COMWTEO AVERAGE VELOCITY (I MILE D5)

/-.4-r.--.

I -L&---._--.-_-.e:\\.:

-- d L C i

$0

--,.-*-,-?-&-,

2 -

7!#+-

?--.--.

I

. .....COMPUTED AVEWGE VELOCITY (I MILE US) 10.5

...-_-.---_I_

FIG. 8.-TYPICAL RESULTS FOR RACCOON MOUNTAIN STUDY although no direct verification of the results can be made because the project is not yet built, confidence can be placed in the results because of past ex-perience gained from the Browns Ferry and CumberlandRiver studies in which verification was achieved.

The Nickajack Reservoir is mathematically described using a A x of 2.1 miles. The upstream boundary is Chickamauga Dam and the downstream boundary is Nickajack Dam. The Raccoon Mountain plant inflow or outflow is introduced uniformly over the 2.1-mile computation reach as either a positive or negative local inflow, depending upon the mode of plant operation.

Base reservoir flows of 0 cfs, 50,000 cfs, and 100,000 cfs with the purnp-turbine discharge of 20,000 cfs introduced as a local inflow are prescribed at the upstream and downstream boundaries,corresponding to the practical range of flows under which navigation occurs.

EIY 5 UNSTEADY FLOW SIMULATION 1569 Fig, 8 shows the effect of the project on water surface elevations and velocities for the 50,000 cfs base flow case. The computed quantities in this figure are those at the ends of a computation reach-about 1 mile upstream and downstream from the plant. The initial upstream and downstream stages and velocities are slightly different because of different cross-sectional areas and their 2 -mile separation.

When the Raccoon Mountain turbine operation starts, the stage rises while the velocity increases downstream and decreases upstream, due to the vector addition of velocity components, a s shown in Fig. 9. After the first 20 min the stage continues to rise, but at a slower rate, and the velocity oscil-lates around a new steady-state value. When the turbine operation stops the velocity returns to the original steady flow value in about 20 min and os-cillates around this value before steadying out. During the pumping cycle, the conditions described previously are more or less reversed. The results of the study show that the proposed normal operation of the pumped-storage plant will not cause severe changes in stage and velocity and, therefore, will not adversely affect navigation conditions in Nickajack Reservoir.

Curnberlmtd Steam Plant Studies. -The TVA is constructing, on the shores of the Corps of Engineers Barkley lake, the world's largest conventional thermal generating plant. Transient flow studies similar to those performed for the Browns Ferry plant were again necessary to provide data for design of the plants cooling water facilities. In this reservoir the studies were com-plicated by the fact that Barkley Lake is directly coupled to The TVA's Kentucky Lake by a large navigation canal.

VELOCITY DECREASE VELOCITY INCREASE TURBINE OPERATlON PUMP OPERATION FIG. 9.-SCHEMATIC REPRESENTATION OF PUMP-TURBINE OPERATIONS, RAC-COON MOUNTAIN STUDY

1570 September, 1969 HY 5 Flow can be either into or fromBarkley Lake depending upon the operating levels of these two reservoirs. In a 400-ft wide, 20-ft deep canal these flows are large even for small head differences between the canal ends, Conse-quently, the transient canal behavior hadto be determined before the transient conditions in the reservoir proper could be adequately assessed.

Stages at the ends of the canal have been recorded since the canal was first opened in 1966. In addition to these continuous stage records periodic canal discharge measurements were also available. Using the best discharge measurements, i.e., those taken when nearly a constant head differential existed between the canal ends for a period sufficiently long to obtain a good discharge measurement, the mathematical model was calibrated. Once cali-brated, the transient canal behavior for any period of time could be determined FIG. 10.-TYPICAL RESULTS FOR KENTUCKY-BARKLEY STUDY by prescribing the water surface elevations which had prevailed at the canal ends. Typical calculated results are shown in Fig. 10. This figure also con-tras ts two field discharge measurements with the calculated results. One taken during a period of nearly constant head difference is good. The other obtained during a period of stage reversal between the canal ends is poor.

This figure also shows that up to 2 h r is required for the flow in the canal to reverse after a reversal in stage difference, depending upon the initial rate of flow. This performance could not be represented by steady flow functions.

It was also found that there is little variation in flow along the length of the canal, because of its relatively short length. The model could be easily adapted to a routine operation to provide daily or other periodic values of

HY 5 UNSTEADY FLOW SIMULATION 1571 canal flow at minimal cost. The results in Fig. 10 show that flow measure-ments should be made only during carefully determinedtime intervals.

Using the computer-determined canal flows, known local inflows, and turbine releases at Barkley and Cheatham Dams, the model was calibrated against known stages at gage locations in the 118-mile long Barkley Reservoir.

The calibrated model was then used to compute stages, velocities and flows throughout the reservoir for a selected month-long period of widely varying actual discharges at the two dams. A portion of the results is shown in Fig. 11.

Generally, agreement exists between computed and measured stages. The accuracy of the stage records themselves, as well as the turbine and local LEGEND OBSERVE0

--- COMPUTED FIG. 11.-TYPICAL RESULTS FOR CUMBERLAND STEAM PLANT STUDY, BARKLEY RESI3ZVOIR flows for this particular reservoir, is not as well defined as it is for some of the other studies cited. Therefore, in view ofpast experience, it is likely that the computer results are as precise as the measured stages. From Fig. 11 it can be seen that shutoffs at the upstream Cheatham plant create low and even negative flows at the plant site.

Colu?ubia P i e c f Stzcdy.-The Duck River, a major tributary of the lower Tennessee, is subject to frequent and severe floods. The TVA is studying the feasibility of constructing a multipurpose dam and reservoir on this river a

1572 September, 1969 HY 5 few miles upstream from the city of Columbia, Tennessee (see Fig. 1). This dam, the Columbia project, would create a reservoir 54 miles long and raise the water level about 80 ft at the dam site. Quoting directly from Ref. 4:

"The formation of a long reservoir in a natural drainage basin may materially alter the regimen of flood runoff by synchronizing high rates of runoff originating above the head of the reservoir with maximum rates from areas contributing laterally to the reservoir. Under nat-ural river conditions, runoff from the upper portion of a basin is re-tarded by valley storage and normal frictional resistance as it passes through the reservoir reach, the resultant velocity corresponding to that indicated by Manning's formula for flow in open channels. How-ever after a deep reservoir has been formed by construction of a dam inflow near the upper end of the reservoir moves through the pool largely by a process of translation, with long-wave velocities sub-ject to momentum control equal approximately to in which fl is the depth of flow in feet and y is the acceleration due to gravity (32.2).

Estimates of the time required for flood waves to traverse natural FIG. 18.-TYPICAL ItESU TATS FOR COLllhZSlA RESE'.RVOIn-DUCK R1VI:R S'I'UDY, hI.4XIMUM PROBABLE FLOOD river channels within the limits of several proposed reservoirs have ranged from a few hours to approximately 1-112 days, whereas the time required for inflow into the upper end of the full reservoir to become effective at the point of reservoir outflow would range from practically zero to a few hours for comparable storms. Changes in the synchronization of runoff from various portions of a drainage ba-sin may be such as to produce rates of inflow into a full reservoir that are substantially higher than would occur at the damsite under natural river conditions, although in some cases the differences may be negligible."

Quasisteady flow routings of the maximum probable flood through both the natural river and the proposed reservoir showed that "reservoir acceleration" could be a factor; therefore, studies were made using the mathematical model.

The model was calibrated using the maximum knownflood (1948) in the natural river. It was then used to route the same flood in the proposed reservoir.

The maximum probable flood for $he river and reservoir were also studied.

HY 5 UNSTEADY FLOW SIMULATION 1573 The hydraulic roughness calibration of the model for the natural river was one of the major problems in this study. Determination of the rating curve for the downstream boundary was also a major problem. The routing of the 1948 flood through the proposed reservoir showed an acceleration of the arrival of the peak as expected. The acceleration effect was much more evident in the case of the maximum probable flood. The spillway operation used with these routings called for storing the initial inflow until top of gates was reached, holding this elevation by means of gated operation until free discharge occurred, and then following the spillway rating. Results for the maximum probable case are shown in Fig. 12.

Maximum inflow hydrographs for the upstream end of the Duck River and for a number of tributaries and runoff reaches were prescribed. Tables of water surface elevation vs. discharge were prescribed at the downstream boundary (Columbia Dam site).

Although downstream flooding, in the case of extremely large floods of the magnitude of the maximum probable flood, would be worsened by the ex-istence af the dam, damage for smaller floods, including the largest flood of record, would be eliminated or greatly reduced by the project. This study affords an excellent example of the use of the mathematical model as a plan-ning tool, in which adequate spillway capacity i s an important factor.

LIMITATIONS From the studies described in this paper, from other studies of similar and specialized natures, and from the basic computation scheme employed, several limitations of the mathematical model, none of them too serious, have been found. These are:

1. Stability and convergence of the computation scheme. This has created some problems in the past, but these are now resolved (8).
2. The explicit scheme requires short time and distance steps when longer intervals are often desirable.
3. Tributary flows must be distributed uniformly over a minimum dis-tance of one computation reach. This is no real problem, because A s may be made smaller, or a short reach containing the tributary can be rerun with internal boundary conditions computed from a previous run.
4. Flows in dry or nearly dry channels cannot be computed.
5. Supercritical flows cannot be calculated.
6. Bores cannot be computed.
7. Branching flows or complex system flows can only be computed by successive applications of the model. No situation has developed to date, however, where this approach has not worked.
8. Stratified flows cannot be computed with the model described herein, but the model can be extended to cover these flows.
9. Some distortion of wave speed occurs in regions where rapid changes occur due to the nature of the computation scheme used. This has not been a problem of any consequence to date.
10. Slight differences in computed results occur between timelines with boundary points and those without boundary points, again due to the compu-tation scheme employed. This has been no real problem. Work is underway

1574 September, 1969 HY 5 to overcome these limitations through different computation schemes, special subroutines, and generalized programs.

SUMMARY

AND CONCLUSIONS Mathematical models for solving the basic differential equations of un-steady flows in open channels are developed and used with the digital com-puter to solve a variety of flow problems in rivers and reservoirs.

The basic model has been verified against actual field measurements of stage and water velocity in both rivers and reservoirs. Other models are being developed to complement and extend the basic model and to handle special complex flow situations. By properly calibrating an appropriate model for a particular river or reservoir channel, time variations in stage, velocity, and water flow can be accurately predicted at any desired location along the channel from prescribed flow conditions at each end of the channel and through tributaries.

The examples described in'this paper show the potential of the unsteady flow mathematical model in a wide variety of engineering problems. A few of its uses in other areas would be:

1. To complement present methods of measuring discharges in the field; the model would show when suitable measurement periods occur.
2. To aid in analysis and monitoring of water quality parameters in rivers and reservoirs. The model would show the actual movement of a mass of water in a flow system, giving accurate definitions of decay times, uptake times, exposure times, etc., regardless of the system unsteadiness. It could also be used as the basis for regulating industrial pollution loads on the basis of flow (dilution) and to maintain desired flows.
3. To select the best locations for future plant sites on the basis of the most desirable flow conditions.
4. To create any desired flow condition along regulated stream by Pro-graming flows at the upstream or downstream ends, or both, of the channel.
5. To aid in system operation of a network of reservoirs where certain portions of the flow are unregulated, such as in canals connecting reservoirs, large tributaries, etc.
6. To route large floods through a reservoir or river reach, thereby pre-dicting stages and flows all along the reach.
7. To study dam failure problems,
8. To establish accurate resistance coefficients in open channels.
9. To obtain steady-flow backwater curves precisely.
10. To separate and analyze storm hydrographs.

It is believed that this type of approach to the more complex flow problems is one that holds promise. Withthis tool, if the flow situation can be described with a differential equation, then the problem can be solved by digital com-puter. This new approach yields accurate and flexible results for a minimal cost once the model is developed. It also promotes a thorough understanding of the dynamics of real flows and should bring about new trends in field data collection for direct input to the computer model. Once experience with

HY 5 USSTEADY FLOW SIMULATION 1575 this approach has been obtained, return to the older, conventional methods is not expected.

APPENDIX 1.-REFERENCES I. ~ b b o t t, M. B., and Ionescu. F., "On the Numerical Cornpuration of Nearly Horizontal Flows,"

Jorrrnul of lI.~~irtlulic~

Kr.rc~orc*lr, Interncltional Associn~iun lor flydriulic Rcsearch. Vol. 5. No. 2.

1967, pp. 96-1 17.

2. Bdtzcr, R. A.. and Lai. C.,

"Computer Simulation of Unsteady Flows in Waterways," Proceed-ings, Jo~trtral oj the ffj~drudic.~

Di~isioti. ASC E, Vol. 94, Nu. HY4. Proc. Papcr 6048, fu!?,

1968. pp. 1083 1 1 17.

3. Buehler, 0.. Pricc, J.T.., and Garrjsun. J. M.,Transient Flow Invstigations for TVh's 8ru\\rns Ferry Generating Station." Pror~edings. 7th..innualSanituri~ utld Water Rt.sortrcr2s Con/c.ren(~e.

Vnnderbilt University. N;ishvilIe,Tenn., May 1968.

4. Flood-Hydro~raph A nofysus and Lbtt~purarions, U S. Corps of Engineers, EM 1 1 10

1405, U.S. Ciovcrnment Printing Office. Washington. D.C., August 1959.

5. Keulegan, G. H., "Wave Motion," Enginewing fI~&aulics, H. Rouse, ed., 3rd ed., John Wile!

& Sons. Inc.. New York, t9hl.

6. Ligge~t. J. A., and Woolhiscr, D. A., "Finite-Difference Solutions of thc Shallow Water Equx-

[ions." Cornell Universiiy Watcr Resuurces Centw. Ithnca, N.Y.. 1966.

7. McLaughlin, R. T.. Kim, C., and Dailry. J. E.. "Unsteady Flow in Reservoirs Operated for Peak Power," Hydrodynamics Laboratory, Massachusetts Institute of Technology, Report /Yo. 101, November 1966.
8. Perkins. F. E., "The Role of Damping in the Stability of Finite Difference Techniques," ASCE National Meeting on Environmental Engineering, Meetinf Preprinr 689, Chattanooga, Tenn.,

May 13-17, 1968.

9. Rutter. E. J., and Engstrom, 1. R., "I-fydrology of Flow Control, Part 111. Reservoir Repula-tion,".4pplied Ifidrolo~~..

V. T. Chow. ed., McGraw-Hill Book Co., Inc. New York, iY@, pp.

15-82 25-85.

10. Stoker, J. J.. "Numerical Solution of Flood Prediction and River Regulation Problrms," N e w York University, Institute of Mathematical Sciences, Heports i undll, New York, 1953-54.

1 I. Streelrr, V. 1.. and Wylie. E. B.. "Opcn-Channel Transient Flow," Hydraulic Trun.rieni.r.

McGraw-Hill Book Co., Inc., New York. 1967. pp. 239-259, APPENDIX II. -NOTATION The following symbols are used in this paper:

cross-sectional flow area, or region of x-t plane; weighted width of channel cross section. or region of s-t plane; acceleration of gravity; water surface elevation above mean sea level; Manning's resistance coefficient; discharge given by mean velocity times cross-sectional flow area; Ialcrrrl inflow pcr unit distance along channel and pcr unit time;

1576 September, 1969 HY 5 R = hydraulic radius given by ratio of cross-sectional flow area to wetted perimeter; Sf = energy gradient; So = channel bottom slope; t = time; V = mean flow velocity; x = distance along channel; hf = time increment; Ax = distance increment; a/at = rate of change with respect to time; and a/ax = rate of change with respect to distance.