ML070400252

From kanterella
Jump to navigation Jump to search
E-Mail from T. Rice of Department of Environmental Conservation to J. Adler of Entergy and J. Noggle of USNRC, Regarding NYS IP Final Results
ML070400252
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 11/09/2006
From: Rice T
State of NY, Dept of Environmental Conservation
To: James Adler, Noggle J
Entergy Corp, NRC/RGN-I/DRS/PSB2
References
FOIA/PA-2007-0080
Download: ML070400252 (2)


Text

tJams 9le - NYS IP FINAL RESULTS Page 1JI From:

"Timothy Rice" <tbrice@gw.dec.state.ny.us>

To:

"Joseph J. Adler" <jadler@entergy.com>, "James Noggle" <JDN@nrc.gov>

Date:

Thu, Nov 9, 2006 1:18 PM

Subject:

NYS IP FINAL RESULTS Hello Jay and Jim, Attached is an excel file w/final State results for August and early Sept.

It agrees fairly well with NRC results, as the preliminary #s had suggested.

Tim

LINC IPEC Collection TRITIUM Sr9O Sample Number NUMBER Date RESULT pCi/L 200620865087 MW-30 74' depth waterloo system 08/18/2006 2.49E+05

+/-

7.6E+03 0.7 200620865088 MW-30 88' depth waterloo system 08/22/2006 4.52E+04

+/-

1.8E+03 0.7 200620865122 MW 57 @ 45 foot depth 08/24/2006 4.12E+03

+/-

2.5E+02 24.9

+/-

1.1 200620865123 MW 55 @ 78 foot depth 08/25/2006 1.47E+04

+/-

5.8E+02 30.2 1.2 200620865124 MW 53 @ 80 foot depth 08/23/2006 1.21 E+04 5.OE+02 9.3

+/-

0.6 200620865125 MW 53 @ 120 foot depth 08/30/2006 3.99E+03

+

2.5E+02 20.1

+/-

0.9 200620865126 MW 54 @ 206 foot depth 09/07/2006 2.47E+03

+/-

1.9E+02 15.0

+/-

0.9 200620865127 MW 56 @ 85 foot depth 09/08/2006 8.34E+02 1.3E+02 2.2

+/-

0.5 200620865128 MW 65 @ 80 foot depth 09/08/2006 2.34E+02

+/-

1.1E E+02 0.5