ML070120119
| ML070120119 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie |
| Issue date: | 01/08/2007 |
| From: | Moroney B NRC/NRR/ADRO/DORL/LPLII-2 |
| To: | |
| Moroney B, NRR/DORL, 415-3974 | |
| Shared Package | |
| ML070120145 | List: |
| References | |
| TAC MD3500, TAC MD3501 | |
| Download: ML070120119 (5) | |
Text
January 8, 2007 LICENSEE:
Florida Power and Light Company FACILITY:
St. Lucie Nuclear Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF JANUARY 10, 2007, MEETING WITH FLORIDA POWER AND LIGHT COMPANY ON ADOPTION OF ALTERNATE SOURCE TERM FOR THE ST. LUCIE NUCLEAR PLANT (TAC NOS. MD3500 AND MD3501)
On January 10, 2007, a Category 1 public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) staff and representatives of Florida Power and Light Company (the licensee) at NRC Headquarters, Two White Flint North, 11545 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss a proposed license amendment request (LAR) to adopt alternate source term for the St. Lucie plant. A list of attendees is enclosed.
The licensee presented information (see the Agencywide Documents Access and Management System (ADAMS) accession number ML070110027). The licensees presentation included the background and purpose of the proposed LAR, the scope of the analyses to be provided for each unit, the regulatory guidance that will be addressed, the proposed conforming technical specifications changes, and the planned schedule for submittal.
The NRC staff queried the licensee about the need date for approval. The licensee indicated it would need approval prior to the next control room ventilation system tracer gas test in 2009.
The licensee stated that there were no other LARs currently planned that would impact the review of the proposed LAR, although there is a possibility that other regulatory actions associated with control room habitability might require an earlier approval.
The NRC staff indicated that, based on the information provided in its presentation, the licensee appeared to be addressing current regulatory guidelines associated with alternate source term.
The staff advised the licensee to clearly indicate the bases and assumptions used in its analyses and, if there are any proposed deviations from NRC guidelines, to identify them and provide appropriate justification. In response to a licensee question, the staff indicated that there were no new requirements being developed that would impact the proposed LAR.
Members of the public were not in attendance. Public Meeting Feedback forms were not received.
Please direct any inquiries to me at 301-415-3974, or btm3@nrc.gov.
Brendan T. Moroney, Project Manager /RA/
Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-335 and 50-389
Enclosure:
List of Attendees cc w/encl: See next page
Enclosure MEETING WITH FLORIDA POWER AND LIGHT COMPANY ON ADOPTION OF ALTERNATE SOURCE TERM FOR THE ST. LUCIE NUCLEAR PLANT JANUARY 10, 2007 LIST OF ATTENDEES NRC FPL B. Moroney T. Patterson B. Mozafari C. Wasik M. Kotzalas V. Rubano R. Dennig J. Kabadi A. Hiser J. Hoffman M. Hart K. Ward D. Duvigneaud K. Frehafer A. Boatright M. Pope, Numerical Applications, Inc.
L. Brown M. Blumberg N. Greene
January 8, 2007 LICENSEE:
Florida Power and Light Company FACILITY:
St. Lucie Nuclear Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF JANUARY 10, 2007, MEETING WITH FLORIDA POWER AND LIGHT COMPANY ON ADOPTION OF ALTERNATE SOURCE TERM FOR THE ST. LUCIE NUCLEAR PLANT (TAC NOS. MD3500 AND MD3501)
On January 10, 2007, a Category 1 public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) staff and representatives of Florida Power and Light Company (the licensee) at NRC Headquarters, Two White Flint North, 11545 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss a proposed license amendment request (LAR) to adopt alternate source term for the St. Lucie plant. A list of attendees is enclosed.
The licensee presented information (See the Agencywide Documents Access and Management System (ADAMS) accession number ML070110027). The licensees presentation included the background and purpose of the proposed LAR, the scope of the analyses to be provided for each unit, the regulatory guidance that will be addressed, the proposed conforming technical specifications changes, and the planned schedule for submittal.
The NRC staff queried the licensee about the need date for approval. The licensee indicated it would need approval prior to the next control room ventilation system tracer gas test in 2009.
The licensee stated that there were no other LARs currently planned that would impact the review of the proposed LAR, although there is a possibility that other regulatory actions associated with control room habitability might require an earlier approval.
The NRC staff indicated that, based on the information provided in its presentation, the licensee appeared to be addressing current regulatory guidelines associated with alternate source term.
The staff advised the licensee to clearly indicate the bases and assumptions used in its analyses and, if there are any proposed deviations from NRC guidelines, to identify them and provide appropriate justification. In response to a licensee question, the staff indicated that there were no new requirements being developed that would impact the proposed LAR.
Members of the public were not in attendance. Public Meeting Feedback forms were not received.
Please direct any inquiries to me at 301-415-3974, or btm3@nrc.gov.
Brendan T. Moroney, Project Manager /RA/
Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-335 and 50-389
Enclosure:
List of Attendees cc w/encl: See next page Distribution: See next page ADAMS ACCESSION NO:ML070120119 - Package: ML070120145 - Meeting Haouts: ML070110027 NRC001 OFFICE LPL2-2/PM LPL2-2/PM LPL2-2/LA LPL2-2/BC(A)
NAME BMoroney BMozafari BClayton DATE 01/16/07 01/17/07 01/16/07 01/18/07 OFFICIAL RECORD COPY
January 8, 2007
SUBJECT:
SUMMARY
OF JANUARY 10, 2007, MEETING WITH FLORIDA POWER AND LIGHT COMPANY ON ADOPTION OF ALTERNATE SOURCE TERM FOR THE ST. LUCIE NUCLEAR PLANT (TAC NOS. MD3500 AND MD3501)
Distribution:
PUBLIC LPL2-2 R/F RidsNrrDorlLpl2-2 RidsNrrPMBMoroney RidsNrrPMBMozafari RidsNrrLABClayton RidsOgcRp RidsAcrsAcnwMailCenter SSanders, NRR SCampbell, EDO RidsNrrDciCsgb RidsNrrDraAadb RidsNrrDssScvb MHart, NRR LBrown, NRR DDuvigneaud, NRR ABoatright, NRR NGreene, NRR MBlumberg, NRR
Mr. J. A. Stall ST. LUCIE PLANT Florida Power and Light Company cc:
Mr. William E. Webster Vice President, Nuclear Operations Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Senior Resident Inspector St. Lucie Plant U.S. Nuclear Regulatory Commission P.O. Box 6090 Jensen Beach, Florida 34957 Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 M. S. Ross, Managing Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Marjan Mashhadi, Senior Attorney Florida Power & Light Company 801 Pennsylvania Avenue, NW.
Suite 220 Washington, DC 20004 Mr. Douglas Anderson County Administrator St. Lucie County 2300 Virginia Avenue Fort Pierce, Florida 34982 Mr. William A. Passetti, Chief Department of Health Bureau of Radiation Control 2020 Capital Circle, SE, Bin #C21 Tallahassee, Florida 32399-1741 Mr. Gordon L. Johnston Site Vice President St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000 Mr. Christopher R. Costanzo Plant General Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957 Mr. Terry Patterson Licensing Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957 Mark Warner, Vice President Nuclear Operations Support Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Rajiv S. Kundalkar Vice President - Nuclear Engineering Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. J. Kammel Radiological Emergency Planning Administrator Department of Public Safety 6000 Southeast Tower Drive Stuart, Florida 34997 Mr. Bill Parks Operations Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000 Mr. Seth B. Duston Training Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000