December 28, 2006 Mr. James H. Riley, Director Engineering Nuclear Energy Institute Suite 400 1776 I Street, NW Washington, DC 20006-3708
SUBJECT:
REVIEW OF MRP-175, MATERIALS RELIABILITY PROGRAM: PWR INTERNALS AGING DEGRADATION MECHANISM SCREENING AND THRESHOLD VALUES (TAC NO. MD2435)
Dear Mr. Riley:
By letter dated July 6, 2006, the Nuclear Energy Institute (NEI) submitted, for information only, a non-proprietary version of MRP-175, Materials Reliability Program: PWR Internals Aging Degradation Mechanism Screening and Threshold Values to the U.S. Nuclear Regulatory Commission (NRC). A proprietary version of this document was transmitted to the NRC in a letter dated March 31, 2006.
The NRC has performed a review of MRP-175. The enclosed NRC comments are being provided so that the Materials Reliability Program Committee may consider them in the context of their overall program. No specific response to the comments is required. However, please review the enclosed comments for proprietary information within 15 days of receipt and respond with your determination. The NRC staff will issue a non-proprietary version of our comments.
Sincerely,
/RA/
Stacey L. Rosenberg, Chief Special Projects Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project Nos. 669 and 689
Enclosure:
NRC Comments On MRP-175 cc w/o encl: See next page
December 28, 2006 Mr. James H. Riley, Director Engineering Nuclear Energy Institute Suite 400 1776 I Street, NW Washington, DC 20006-3708
SUBJECT:
REVIEW OF MRP-175, MATERIALS RELIABILITY PROGRAM: PWR INTERNALS AGING DEGRADATION MECHANISM SCREENING AND THRESHOLD VALUES (TAC NO. MD2435)
Dear Mr. Riley:
By letter dated July 6, 2006, the Nuclear Energy Institute (NEI) submitted, for information only, a non-proprietary version of MRP-175, Materials Reliability Program: PWR Internals Aging Degradation Mechanism Screening and Threshold Values to the U.S. Nuclear Regulatory Commission (NRC). A proprietary version of this document was transmitted to the NRC in a letter dated March 31, 2006.
The NRC has performed a review of MRP-175. The enclosed NRC comments are being provided so that the Materials Reliability Program Committee may consider them in the context of their overall program. No specific response to the comments is required. However, please review the enclosed comments for proprietary information within 15 days of receipt and respond with your determination. The NRC staff will issue a non-proprietary version of our comments.
Sincerely,
/RA/
Stacey L. Rosenberg, Chief Special Projects Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project Nos. 669 and 689
Enclosure:
NRC Comments On MRP-175 cc w/o encl: See next page DISTRIBUTION:
PUBLIC PSPB Reading File GCheruvenki RidsNrrDpr RidsNrrDprPspb RidsNrrDciCvib RidsNrrLADBaxley RidsAcrsAcnwMailCenter RidsNrrPMTMensah RidsOgcMailCenter RidsNrrDciCfeb RidsNrrDciCpnb ADAMS ACCESSION NO.: ML063490441 NRR-106 OFFICE DPR/PSPB DPR/PSPB DPR/PSPB NAME TMensah DBaxley SRosenberg DATE 12/28 /06 12/ 27 /06 12/28/06 OFFICIAL RECORD COPY
Nuclear Energy Institute Project No. 689 Electric Power Research Institute Project No. 669 cc:
Mr. Anthony Pietrangelo, Senior Director Risk Regulation Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Mr. H. A. Sepp, Manager Regulatory and Licensing Engineering Westinghouse Electric Company P. O. Box 355 Pittsburgh, PA 15230-0355 Mr. Jack Roe Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Mr. Charles B. Brinkman Washington Operations ABB-Combustion Engineering, Inc.
12300 Twinbrook Parkway, Suite 330 Rockville, MD 20852 Mr. Gary L. Vine, Executive Director EPRI 2000 L Street, NW, Suite 805 Washington, DC 20036-4907 Mr. Pedro Salas Regulatory Assurance Manager - Dresden Exelon Generation Company, LLC 6500 N. Dresden Road Morris, IL 60450-9765 Ms. Barbara Lewis Assistant Editor Platts, Principal Editorial Office 1200 G St., N.W., Suite 1100 Washington, DC 20005 Mr. Gary Welsh Institute of Nuclear Power Operations Suite 100 700 Galleria Parkway, SE Atlanta, GA 30339-5957 Mr. David J. Modeen Vice President and Chief Nuclear Officer EPRI 1300 W. T. Harris Boulevard Charlotte, NC 28262-8550 Mr. John Gaertner EPRI 1300 W.T. Harris Boulevard Charlotte, NC 28262-8550 Ms. Rosa Yang EPRI 3412 Hillview Avenue Palo Alto, CA 94304-1338 Mr. Kenneth Huffman EPRI 1300 W. T. Harris Boulevard Charlotte, NC 28262-8550 Dr. H.T. Tang, Senior Project Manager EPRI 3420 Hillview Avenue Palo Alto, CA 94304-1395 Ms. Kimberly Keithline, Senior Project Manager Nuclear Energy Institute 1776, I street, NW, Suite 400 Washington, D.C, 20006-3708 Mr. Glenn Gardner, Engineer Dominion Nuclear Connecticut Millstone Power Station Rope Ferry Rd Waterford, CT 06385