ML063320241

From kanterella
Jump to navigation Jump to search
NIST Response to Question on Fission Product Release for Re-Licensing Application
ML063320241
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 11/27/2006
From: Richards W
US Dept of Commerce, National Institute of Standards & Technology (NIST)
To: Mendonca M
Office of Nuclear Reactor Regulation
References
Download: ML063320241 (3)


Text

From:

"Wade J. Richards" <wade.richards@nist.gov>

To:

<MMM@nrc.gov>

Date:

11/27/2006 10:55:51 AM

Subject:

RAI

Marvin, Attached is the response to the RAI you sent me. Let me know if further clarification is needed.

Wade J. Richards Chief Reactor Operations & Engineering National Institute for Standards & Technology 100 Bureau Dr.

Gaithersburg, MD 20899 wade-richards@nist.gov (301)-975-6260 Phone (301)-975-8374 Fax

Ictrp\\GW}OOOO1.TMP Pg i Mail Envelope Properties (456BOA79.3C7: 12: 54215)

Subject:

Creation Date From:

Created By:

RAI 11/27/2006 10:55:08 AM "Wade J. Richards" <wade.richards@nist.gov>

wade.richards@nist.gov Recipients nrc.gov TWGWPO01.HQGWDOO1 MMM (Marvin Mendonca)

Post Office TWGWPO01.HQGWDOO1 Files MESSAGE Response to RAI 11.doc Mime.822 Options Expiration Date:

Priority:

ReplyRequested:

Return Notification:

Concealed

Subject:

Security:

Route nrc.gov Size 519 29696 42712 Date & Time 11/27/2006 10:55:08 AM None Standard No None No Standard Junk Mail Handling Evaluation Results Message is eligible for Junk Mail handling This message was not classified as Junk Mail Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled

Response to RAI 1 Question Do we have the calculations and/or analysis to support the statement the "..... less than 3% of the total Iodine released will be present as 1(2) gas?

This statement can be found in section 13.2.1 Maximum Hypothetical Accident (MHA),

paragraph 3 ( All of the noble gas...).

Response

This statement follows from the References "Weber, 19921 and 19932"', and calculations based upon the former in NUREG/CR-5732' (ORNL/TM-12202) and NUREG 1465'. In NUREG CR-5732, the chemical forms of the iodine releases in a light water severe reactor accident are analyzed, and it is shown that under the conditions pertaining to a severe fuel melt, most of the iodine will combine with Cs to from CsI in solution. The origin of this result is the release of Cs during the accident, which immediately goes into solution as CsOH, increasing the local pH (in this response, we use pH throughout rather the more accurate pD when referring to the NBSR. The fact that the primary is heavy water will not affect the analysis in any significant way). As discussed in detail in the references, under these conditions, over 99 % of the 12 in solution will very rapidly convert to CsI. This form is soluble, and is only released by either radiolysis or a small vapor pressure of 12 above the solution that is given by Henry's law, as discussed in the Chapter 13 analysis. NUREG 1465 uses these results to estimate accident source terms, including 12 releases, and concludes that no more than 4 % of the iodine will be present in the water as 12 (with an additional 1 % as HI), even under the severe conditions of a complete fuel melt in a light water reactor. As stated in the references, these results depend only on Iodine chemistry as a function of pH, temperature and, secondarily, radiation (which can convert CsI to 12 at equilibrium levels of up to approximately 3 % at the pH of the NBSR primary). Weber shows in reference 2 that the same chemistry applies to a severe accident in the HFIR, and there is nothing specific to light water in the analysis. The figure used of less than 3 % follows from the fact that this is larger than the largest estimate in Reference 3, which was 2.8 %.

'Weber, C. F., Beahm, E. C., and Kress, T. S. (1992). Models ofIodine Behavior in Reactor Containments. ORNL/TM-12202, Oak Ridge National Laboratory: Oak Ridge, Tennessee.

2 Weber, C. F. and Beahm, E. C. (January 1993). Iodine Transport During a Large Pipe BreakLOCA in the Pipe Tunnel With Drainage Outside Confinement. Research Reactors Division CHFIR-92-032, Oak Ridge National Laboratory Oak Ridge, Tennessee 3 Beahm, E. C., C. F. Weber, and T. S. Kress (July, 1991). Iodine Chemical Forms in LWR Severe Accidents. NUREG/CR-5732 (ORNLITM-1 1861) Oak Ridge National Laboratory: Oak Ridge, Tennessee

' Soffer, L., Burson, S. B., Ferrell, C. M., Lee, R. Y., and Ridgely, J..N. (February, 1995). Accident Source Termsfor Light-Water Nuclear Power Plants. NUREG-1465, U. S. Nuclear Regulatory Commission, Washington, DC