Population impacts for ABWR Population dose within 50-miles (Rem)

I.

Accident Frequency Mean (1998)

Mean (1997)

Mean (1996)

Accident 0

1 2

3 4

5 6

7 8

9 Frequency 1.34E-07 2.08E-08 1.OOE-1 0 1.OOE-10 1.OOE-1 0 1.00&E10 1.OOE-10 3.91 E-10 4.05E-10 1.70E-10 Mean (1998)

Mean (1997) 7.89E+03 1.04E+04 5.61 E+03 4.48E+05 3.39E+05 1.43E+05 2.81 E+06 3.22E+06 4.88E+06 6.24E+06 1.06E-03 2.16E-04 5.61 E-07 4.48E-05 3.39E-05 1.43E-05 2.81 E-04 1.26E-03 1.98E-03 6.57E+03 8.84E+03 4.74E+03 3.80E+05 2.91 E+05 1.21 E+05 2.63E+06 2.98E+06 4.50E+06 8.80E-04 1.84E-04 4.74E-07 3.80E-05 2.91 E-05 1.21 E-05 2.63E-04 1.17E-03 1.82E-03 9.64E-04 Mean 7.45E+03 9.58E+03 5.17E+03 4.23E+05 3.12E+05 1.32E+05 2.71 E+06 3.04E+06 4.60E+06 5.99E+06 (1996) 9.98E-04 1.99E-04 5.17E-07 4.23E-05 3.12E-05 1.32E-05 2.71 E-04 1.19E-03 1.86E-03 1.02E-03 1.06E-031 5.67E+06 TOTAL i

5.94E-031 5.36E-031 5.63E-03 Reported Value Ratio (New / North Anna) 5.93E-03 1.00 5.36E-03 1.00 5.63E-03 1.00 Dollar Risk Assessment (Dollars/year)

Fatalaties per year Farmland Accident Frequency Mean Early Latent HA 0

1.34E-07 1.32E+05 1.77E-02 0 0.OOE+00 3.49E+00 4.68E-07 5.11E+00 1

2.08E-08 1.91 E+05 3.97E-03 0 0.OOE+00 4.75E+00 9.88E-08 5.80E+00 2

1.OOE-10 1.23E+04 1.23E-06 0 0.OOE+00 2.40E+00 2.40E-10 9.57E-03 3

1.OOE-10 1.20E+08 1.20E-02 0 0.OOE+00 2.OOE+02 2.OOE-08 2.47E+03 4

1.OOE-10 8.OOE+07 8.OOE-03 0 0.OOE+00 1.50E+02 1.50E-08 1.72E+03 5

1.O0E-10 4.18E+07 4.18E-03 0 0.OOE+00 6.1OE+01 6.1OE-09 5.19E+02 6

1.OOE-10 6.04E+09 6.04E-01 0 0.OOE+00 1.25E+03 1.25E-07 4.74E+04 7

3.91E-10 6.91E+09 2.70E+00 1.98E-05 7.74E-15 1.42E+03 5.55E-07 4.99E+04 8

4.05E-10 1.24E+10 5.02E+00 5.06E-02 2.05E-11 2.14E+03 8.67E-07 7.OOE+04 9

1.70E-10 1.59E+10 2.70E+00 1.34E-02 2.28E-12 2.94E+03 5.OOE-07 8.11E+04 Total 1.11 E+01 2.28E-1 1 2.65E-06 2.53E+05 Reported Value Ratio (New / North Anna) 1.11E+01 1.00 2.40E-1 1 0.95 2.65E-06 1.00 174480 1.45

Population impacts for ABWR Pooulation dose within 50-miles (Rem) a Accident 0

1 2

3 4

5 6

7 8

9 Frequency 1.34E-07 2.08E-08 1.O0E-10 1.OOE-10 1.OOE-1 0 1.OOE-1 0 11.00E-1 0 3.91 E-10 4.05E-1 0 1.70E-10 Mean 7.89E+03 1.04E+04 5.61 E+03 4.48E+05 3.39E+05 1.43E+05 2.81 E+06 3.22E+06 4.88E+06 6.24E+06 1.06E-03 2.16E-04 5.61 E-07 4.48E-05 3.39E-05 1.43E-05 2.81 E-04 1.26E-03 1.98E-03 1.06E-03 Me 6.01 E+03 7.16E+03 3.66E+03 2.74E+05 1.77E+05 7.99E+04 1.89E+06 2.19E+06 3.31 E+06 4.17E+06 dian 8.05E-04 1.49E-04 3.66E-07 2.74E-05 1.77E-05 7.99E-06 1.89E-04 8.56E-04 1.34E-03 7.09E-04 95%

2.01E+04 2.69E-03 3.17E+04 6.59E-04 1.57E+04 1.57E-06 1.34E+06 1.34E-04 1.11E+06 1.11E-04 4.69E+05 4.69E-05 7.77E+06 7.77E-04 7.85E+06 3.07E-03 1.23E+07 4.98E-03 1.83E+07 3.11E-03 ITOTAL I

5.94E-031 4.1OE-031 1.56E-02 Reported Value 5.93E-03 Ratio (New / North Anna) 1.00 Early Fatalities Accident Frequency Mean Median 95%

0 1.34E-07 0

0.OOE+00 0 0.OOE+00 0.OOE+00 0.OOE+00 1

2.08E-08 0

0.OOE+00 0 0.OOE+00 0.OOE+00 0.OOE+00 2

1.OOE-10 0

0.OOE+00 0 0.OOE+00 0.OOE+00 3

1.OOE-10 0

0.OOE+00 0 0.OOE+00 0.OOE+00 4

1.00E-10 0

0.OOE+00 0 0.OOE+00 0.OOE+00 5

1.OOE-10 0

0.OOE+00 0 0.OOE+00 0.OOE+00 6

1.OOE-10 0

0.OOE+00 0 0.OOE+00 0.OOE+00 7

3.91E-10 1.98E-05 7.74E-15 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 8

4.05E-10 5.06E-02 2.05E-11 5.47E-03 2.22E-12 2.23E-01 9.03E-11 9

1.70E-10 1.34E-02 2.28E-12 0.OOE+00 0.OOE+00 7.11E-02 1.21E-11 Total 2.28E-11 2.22E-12 1.02E-10 Reported Value 2.40E-1 1 Ratio (New / North Anna) 0.95 Latent Cancer Fatalaties (1998)

Accident Frequency Mean Median 95%

0 1.34E-07 3.49E+00 4.68E-07 2.63 3.52E-07 8.84E+00 1.18E-06 1

2.08E-08 4.75E+00 9.88E-08 3.31 6.88E-08 1.26E+01 2.62E-07 2

1.OOE-10 2.40E+00 2.40E-10 1.56 1.56E-10 7.21E+00 7.21E-10 3

1.OOE-10 2.OOE+02 2.OOE-08 119 1.19E-08 5.92E+02 5.92E-08 4

1.OOE-10 1.50E+02 1.50E-08 78.8 7.88E-09 5.07E+02 5.07E-08 5

1.OOE-10 6.1OE+01 6.1OE-09 32.9 3.29E-09 2.17E+02 2.17E-08 6

1.OOE-10 1.25E+03 1.25E-07 8360 8.36E-07 3.29E+03 3.29E-07 7

3.91E-10 1.42E+03 5.55E-07 9.67E+02 3.78E-07 3.07E+03 1.20E-06 8

4.05E-10 2.14E+03 8.67E-07 1.46E+03 5.91E-07 5.32E+03 2.15E-06 9

1.70E-10 2.94E+03 5.OOE-07 1.94E+03 3.30E-07 8.14E+03 1.38E-06 Total 2.65E-06 2.58E-06 6.65E-06 Reported Value Ratio (New / North Anna) 2.65E-06 1.00

Population impacts for North Anna ABWR (1998 met. Data) (0 - 3.2 km)

Individual Risk Early Fatality (EAB+1 mi)

Accident Frequency Mean Median 95%

0 1.34E-07 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1

2.08E-08 0.00E+00 0.00E+00 O.00E+00 0.00E+00 2

1.00E-1 0 O.OOE+00 O.OOE+00 O.OOE+00 OEOOE+00 3

1.00E-1 0 0.OOE+00 0.00E+00 0.00E+00 0.09E-00 4

1.00E-10 0.00E+00 0.00E+00 0.00E+00

.OOE+00 5

1.00E-10 0.OOE+00 0.00E+00 O. O00E+00 oE+00 6

1.00E-10 0.00E+00 0.00E+00 0.OOE+00 0.OOE+00 7

3.91E-10 4.30E-08 1.68E-17 0.00E+00 0.00E+00 8

4.05E-10 1.02E-04 4.13E-14 0.00E+00 0.00E+00 9

1.70E-10 2.90E-05 4.93E-15 0.00E+00 0.00E+00 Total 4.63E-14 0.00E+00 0.00E+00 Reported Value Ratio (New / Reported)

Individual Risk Cancer Fatality (10 mi)

Accident Frequency Mean Median

-95%/

0 1.34E-07 1.95E-05 2.61 E-12 **'

E+00 0.O0E-00 1

2.08E-08 3.79E-05 7.88E-13 O.OOE+00 0.O00E+0*0 2

1.OOE-10 2.78E-05 2.78E-15 O.OOE+00 O.OOE-0 3

1.00E-10 3.11E-04 3.11 E-14 O.OOE+00 O.OOE+00 4

1.00E-10 2.17E-04 2.17E-14 O.OOE+00 O.OOE+00 5

1.00E-10 2.28E-04 2.28E-14 O.OOE+00 O.OOE+00 6

1.OOE-10 6.21E-04 6.21E-14 O.OOE+00 O.OOE+00 7

3.91 E-10 6.94E-04 2.71 E-13 O.OOE+00 O.OOE+00 8

4.05E-10 1.11E-03 4.50E-13 O.OOE+00 O.OOE+00 9

1.70E-10 1.07E-03 1.82E-1 3 O.OOE+00 O.OOEOQ Total 4.44E-12 0 OOE+00*

,.OOE+O0I Reported Value Ratio (New!/ Reported) i<