W@LF CREEK
'NUCLEAR OPERATING CORPORATION November 17, 2006 Kevin J. Moles Manager Regulatory Affairs RA 06-0133 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
Subject:
Docket No. 50-482: Changes to Wolf Creek Generating Station Radiological Emergency Response Data System Data Point Library Gentlemen:
In accordance with 10CFR50 Appendix E.VI.3.a., this letter transmits changes to Wolf Creek Generating Station's (WCGS) Data Point Library (DPL).
The specific changes to the two affected data points are described below.
The Plant Specific Point Description was updated to reflect the modification of the Containment Recirculation Sump level transmitters to differential pressure transmitters.
This modification resulted in a change to the level indication. A typographical error was also corrected.
Attached to this letter are the replacement pages to update the WCGS DPL. These changes were implemented October 20, 2006.
This letter contains no commitments. If you have any questions concerning this matter, please contact me at (620) 364-4126, or Diane Hooper at (620) 364-4041.
Very truly yours, KJM/rlt Attachment cc:
J. N. Donohew (NRC), w/a B. S. Mallett (NRC), w/a G. B. Miller (NRC), w/a Senior Resident Inspector (NRC), w/a P.O. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HC/VET
Attachment to RA 06-0133 Page 1 of 2 WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)
Reactor Unit: (3)
Data Feeder: (10)
NRC ERDS Parameter: (12)
Point ID: (12)
Plant Spec Point Desc: (40)
Generic/Cond Desc: (32)
Analog/Digital: (1)
Engr Units/Dig States: (12)
Engr Units Conversion: (40)
Minimum Instr Range: (10)
Maximum Instr Range: (10)
Zero Point
Reference:
(6)
Reference Point Notes: (40)
PROC or SENS: (1)
Number of Sensors: (3)
How Processed: (40)
Sensor Locations: (40)
Alarm/Trip Set Points: (40)
NI Detector Power Supply Cut-off Power Level: (15)
NI Detector Power Supply Turn-on Power Level: (15)
Instrument Failure Mode: (30)
Temperature Compensation For DP Transmitters: (1)
Level Reference Leg: (3)
Unique System Desc: (100) 10/20/06 WC1 N/A CTMT SMP WR EJL0007 CTMT RECIRC SUMP A LEVEL CTMT EMERGENCY RECIRC SUMP A
ELEV N/A 1994.5 2006.1 1994.5 RELATIVE SITE ELEVATION S
1 N/A INSIDE CTMT AT RECIRC SUMP A N/A N/A N/A LOW=LOP N/A N/A RECIRC SUMP LEVEL XMTR TRAIN A EJLT0007 LOW LIMIT 2 FT 6 IN ABV SUMP FLOOR COMPUTER ALARMS MODE HI FP 2002.2 LP 2002.2 HS 2002.2 HC 2002.2 CS 2002.2 RF 2002.2
Attachment to RA 06-0133 Page 2 of 2 WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)
Reactor Unit: (3)
Data Feeder: (10)
NRC ERDS Parameter: (12)
Point ID: (12)
Plant Spec Point Desc: (40)
Generic/Cond Desc: (32)
Analog/Digital: (1)
Engr Units/Dig States: (12)
Engr Units Conversion: (40)
Minimum Instr Range: (10)
Maximum Instr Range: (10)
Zero Point
Reference:
(6)
Reference Point Notes: (40)
PROC or SENS: (1)
Number of Sensors: (3)
How Processed: (40)
Sensor Locations: (40)
Alarm/Trip Set Points: (40)
NI Detector Power Supply Cut-off Power Level: (15)
NI Detector Power Supply Turn-on Power Level: (15)
Instrument Failure Mode: (30)
Temperature Compensation For DP Transmitters: (1)
Level Reference Leg: (3)
Unique System Desc: (100) 10/20/06 WC1 N/A CTMT SMP WR EJL0008 CTMT RECIRC SUMP B LEVEL CTMT EMERGENCY RECIRC SUMP A
ELEV N/A 1994.5 2006.1 1994.5 RELATIVE SITE ELEVATION S
1 N/A INSIDE CTMT AT RECIRC SUMP B N/A N/A N/A LOW=LOP N/A N/A RECIRC SUMP LEVEL XMTR TRAIN B EJLT0008 LOW LIMIT 2 FT 6 IN ABV SUMP FLOOR COMPUTER ALARMS MODE HI FP 2002.2 LP 2002.2 HS 2002.2 HC 2002.2 CS 2002.2 RF 2002.2