{{#Wiki_filter:Jeffrey B. Archie Vice President, Nuclear Operations 803.345.4214 A SCANA COMPANY November 15, 2006 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
Dear Sirs / Madam:
Subject:
VIRGIL C. SUMMER NUCLEAR STATION DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 CORE OPERATING LIMITS REPORT (COLR) FOR CYCLE 17 In accordance with Section 6.9.1.11 of the Virgil C. Summer Nuclear Station Technical Specifications, South Carolina Electric & Gas Company (SCE&G) hereby submits the Cycle 17 Core Operating Limits Report (COLR). Should you have any questions, please call Mr. Joel E. Ferris at (803) 345-4207.
- Ve*
t
- yours, rey B. Arch JEF/JBA/dr Attachment NOTE: Attachment is on file in NL c:
Without Attachment unless noted K. B. Marsh S. A. Byrne N. S. Carns J. H. Hamilton R. J. White W. D. Travers (w/atta R. E. Martin (w/atta NRC Resident Inspector (w/atta, K. M. Sutton NSRC RTS (L-99-0150) File (818.23-1, RR 5000) DMS (RC-06-0201) chment) chment) chment) -AcO/ SCE&G I Virgil C. Summer Nuclear Station
- P. 0. Box 88
- Jenkinsville, South Carolina 29065 o T (803) 345.5209
- www.scana.com
SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION CORE OPERATING LIMITS REPORT FOR CYCLE 17 REVISION 0 NOVEMBER 2006
LIST OF EFFECTIVE PAGES PAGE REVISION 0
- ii 0
iii 0 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 16 0 17 0 18 0
- 19.
0 20 0 21 0
Table of Contents Section Page 1.0 Core Operating Limits Report 1 2.0 Operating Limits 2 2.1 Moderator Temperature Coefficient (Specification 3.1.1.3) 2 2.2 Shutdown Rod Insertion Limits (Specification 3.1.3.5) 2 2.3 Control Rod Insertion Limits (Specification 3.1.3.6) 2 2.4 Axial Flux Difference (Specification 3.2.1) 3 2.5 Heat Flux Hot Channel Factor - FQ(z) (Specification 3.2.2) 3 2.6 RCS Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor - F' (Specification 3.2.3) 4 2.7 Power Distribution Measurement Uncertainty (Specifications 3.2.2 and 3.2.3) 4 3.0 References 6 Revision 0
List of Tables Table Pame Table 1. RAOC W(z) at 150 MWD/MTU V. C. Summer - Cycle 17 11 Table 2. RAOC W(z) at 3000 MWD/MTU V. C. Summer - Cycle 17 12 Table 3. RAOC W(z) at 10000 MWD/MTU V. C. Summer - Cycle 17 13 Table 4. RAOC W(z) at 20000 MWD/MTU V. C. Summer - Cycle 17 14 Table 5. RAOC FQ Margin Decreases in Excess of 2% Per 31 EFPD - Cycle 17 15 Table 6. Baseload W(z) at 150 MWD/MTU V. C. Summer - Cycle 17 16 Table 7. Baseload W(z) at 3000 MWD/MTU V. C. Summer - Cycle 17 17 Table 8. Baseload W(z) at 10000 MWD/MTU V. C. Summer - Cycle 17 18 Table 9. Baseload W(z) at 20000 MWD/MTU V. C. Summer - Cycle 17 19 Table 10. Baseload FQ Margin Decreases in Excess of 2% Per 31 EFPD - Cycle 17 20 ii Revision 0
List of Figures Figure Page Figure 1. Moderator Temperature Coefficient Versus Power Level V. C. Summer - Cycle 17 7 Figure 2. Rod Group Insertion Limits Versus Thermal Power for Three Loop Operation V. C. Summer - Cycle 17 8 Figure 3. Axial Flux Difference Limits as a Function of Rated Thermal Power V. C. Summer - Cycle 17 9 Figure 4. K(z) - Normalized FQ(z) as a Function of Core Height V. C. Summer - Cycle 17 10 Figure 5. RCS Total Flowrate vs. R for Three Loop Operation V. C. Summer - Cycle 17 21 iii Revision 0
V. C. Summer Cycle 17 November 2006 1.0 Core Operating Limits Report This Core Operating Limits Report (COLR) for V. C. Summer Station Cycle 17 has been prepared in accordance with the requirements of Technical Specification 6.9.1.11. The Technical Specifications affected by this report are listed below: 3.1.1.3 Moderator Temperature Coefficient 3.1.3.5 Shutdown Rod Insertion Limits 3.1.3.6 Control Rod Insertion Limits 3.2.1 Axial Flux Difference 3.2.2 Heat Flux Hot Channel Factor 3.2.3 RCS Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor 3.3.3.11 Power Distribution Measurement Uncertainty 1 Revision 0
V. C. Summer Cycle 17 November 2006 2.0 Operating Limits The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the subsections which follow. These limits have been developed using the NRC-approved methodologies specified in Technical Specification 6.9.1.11. 2.1 Moderator Temperature Coefficient (Specification 3.1.1.3): 2.1.1 The Moderator Temperature Coefficient (MTC) limits are: The BOL/ARO-MTC shall be less positive than the limits shown in Figure 1. The EOL/ARO/RTP-MTC shall be less negative than -5x10-4 Ak/k/IF. where: BOL stands for Beginning of Cycle Life ARO stands for All Rods Out RTP stands for RATED THERMAL POWER EOL stands for End of Cycle Life 2.1.2 The MTC Surveillance limit is: The 300 ppm/ARO/RTP-MTC should be less negative than or equal to -4. 1x10-4 Ak/k/°F 2.1.3 The Revised Predicted near-EOL 300 ppm MTC shall be calculated using the following algorithm from Reference 2: Revised Predicted MTC = Predicted MTC + AFD Correction*+ Predictive Correction**
- AFD Correction is 0.05 pcm/°F/%AAFD.
- Predictive Correction is -3 pcm/°F.
If the Revised Predicted MTC is less negative than the SR 4.1.1.3b limit of -4. 1x10-4 Ak/k]°F, and all of the benchmark data contained in the surveillance procedure are met, then an MTC measurement in accordance with SR 4.1.1.3b is not required. 2.2 Shutdown Rod Insertion Limits (Specification 3.1.3.5): The shutdown rods shall be withdrawn to at least 230 steps. 2.3 Control Rod Insertion Limits (Specification 3.1.3.6): Control Bank A and B rods shall be withdrawn to at least 230 steps. Control Bank C and D Insertion Limits are specified by Figure 2. Control rod overlap is 102 steps. 2 Revision 0
V. C. Summer Cycle 17 November 2006 2.4 Axial Flux Difference (Specification 3.2.1): 2.4.1 The Axial Flux Difference (AFD) Limits for RAOC operation for Cycle 17 are shown in Figure 3. 2.4.2 The Axial Flux Difference (AFD) target band during base load operations for Cyclel7 is: BOL - EOL (0 - 23,800 MWD/MTU): +/-5% about a measured target value. 2.4.3 The minimum allowable power level for base load operation, APLND, is 75% of RATED THERMAL POWER. 2.5 Heat Flux Hot Channel Factor - FQ(z) (Specification 3.2.2): FQ (Z)
- Q x K(Z) for P > 0.5 P
FQ (Z) <* -- x K(Z) for P < 0.5 where: P Thermal Power 0.5 Rated Thermal Power 2.5.1 FQRT =2.40 2.5.2 K(z) is provided in Figure 4. 2.5.3 Elevation dependent W(z) values for RAOC operation at 150, 3000, 10000, and 20000 MWD/MTU are shown in Tables 1 through 4, respectively. This information is sufficient to determine W(z) versus core height in the range of 0 MWD/MTU to EOL burnup through the use of three point interpolation. Table 5 shows FQ margin decreases for RAOC operation that are greater than 2% per 31 Effective Full Power Days (EFPD). These values shall be used to increase FQM(z) as per Surveillance Requirement 4.2.2.2e. A 2% penalty factor shall be used at all burnups that are outside the range of Table 5. 2.5.4 Elevation dependent W(Z)BL values for Baseload operation between 75 and 100% of rated thermal power with the item 2.4.2 specified target band about a measured target value at 150, 3000, 10000, and 20000 MWD/MTU are shown in Tables 6 through 9, respectively. This information is sufficient to determine W(Z)BL versus core height for burnups in the range of 0 MWD/MTU to EOL burnup through the use of three point interpolation. Table 10 shows FQ margin decreases for base load operation that are greater than 2% per 31 Effective Full Power Days (EFPD). These values shall be used to increase FQM(z) as 3 Revision 0
V. C. Summer Cycle 17 November 2006 per Surveillance Requirement 4.2.2.4e. A 2% penalty factor shall be used at all burnups that are outside the range of Table 10. 2.6 RCS Flow Rate and Nuclear Enthalpy Rise Hot Channel Factor - F.N (Specification 3.2.3): FN R - F,,H FTP x (I + PFN x(1- ) where: P = Thermal Power Rated Thermal Power 2.6.1 Fffj" :1.62 2.6.2 PFOH 0.3 2.6.3 The Acceptable Operation Region from the combination of Reactor Coolant System total flow and R is provided in Figure 5. 2.7 Power Distribution Measurement Uncertainty (Specifications 3.2.2 and 3.2.3): If the Power Distribution Monitoring System is OPERABLE, as defined in Technical Specification 3.3.3.11, the uncertainty, UFAH, to be applied to the Nuclear Enthalpy Rise Hot Channel Factor FNA shall be calculated by the following formula: UFAH = 1.0 + UAH 100.0 where: UAH = Uncertainty for enthalpy rise as defined in equation (5-19) in Reference 1. 4 Revision 0
V. C. Summer Cycle 17 November 2006 If the Power Distribution Monitoring System is OPERABLE, as defined in Technical Specification 3.3.3.11, the uncertainty, UFQ, to be applied to the Heat Flux Hot Channel Factor FQ(z) shall be calculated by the following formula: UFQ=1.0+ 1-.0 Ue where: UQ = Uncertainty for power peaking factor as defined in equation (5-19) in Reference 1. Ue = Engineering uncertainty factor. = 1.03 If the Power Distribution Monitoring System is INOPERABLE, as defined in Technical Specification 3.3.3.11, the uncertainty, UFAH, to be applied to the Nuclear Enthalpy Rise Hot Channel Factor F NAH shall be calculated by the following formula: UFAH - UFAHm where: UFAHm = Base FAH measurement uncertainty. = 1.04 If the Power Distribution Monitoring System is INOPERABLE, as defined in Technical Specification 3.3.3.11, the uncertainty, UFQ, to be applied to the Heat Flux Hot Channel Factor FQ(z) shall be calculated by the following formula: UFQ = Uqu - Ue where: Uqu = Base FQ measurement uncertainty. = 1.05 U, = Engineering uncertainty factor. = 1.03 5 Revision 0
V. C. Summer Cycle 17 November 2006 3.0 References
- 1) WCAP-12473-A (Non-Proprietary), "BEACON Core Monitoring and Operations Support System," August, 1994.
- 2) WCAP-13749-P-A, "Safety Evaluation Supporting the Conditional Exemption of the Most Negative EOL Moderator Temperature Coefficient," March 1997, (Proprietary).
6 Revision 0
V. C. Summer Cycle 17 November 2006 Figure 1. Moderator Temperature Coefficient Versus Power Level V. C. Summer - Cycle 17 1.00 0.90 0.80 LLi 0 CL 0 C-0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 L 0 10 20 30 40 50 60 70 Percent of Rated Thermal Power 80 90 100 7 Revision 0
V. C. Summer Cycle 17 November 2006 Figure 2. Rod Group Insertion Limits Versus Thermal Power for Three Loop Operation V. C. Summer - Cycle 17 0.r_ .20a. o 0. It.O, n-230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 (0.55, 230) (1.0,194) BANK C BANK D OVERLAP 102 steps (0.048,0) 1 1 1 1 1 1 1 61 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Percent of Rated Thermal Power 0.8 0.9 1 8 Revision 0
V. C. Summer Cycle 17 November 2006 Figure 3. Axial Flux Difference Limits as a Function of Rated Thermal Power V. C. Summer - Cycle 17 120 [ (-8,1oo) ](+8, 100) 100__ JjUnacceptable U naccepta le 20 Acceptable] E 60
- a.
4 20 -40 -30 -20 -10 0 10 20 30 40 Axial Flux Difference (%AI) Revision 0
V. C. Summer Cycle 17 November 2006 Figure 4. K(z) - Normalized FQ(z) as a Function of Core Height V. C. Summer - Cycle 17 1.10 1.00 0.90 0.80 I-a. LL 0N Cu_ 0z 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 (0.0, 1.0)(6010 0 Bottom 2 4 6 Core Height (Feet) 10 8 10 12 Top Revision 0
V. C. Summer Cycle 17 November 2006 Table 1. RAOC W(z) at 150 MWD/MTU V. C. Summer - Cycle 17 Core Height W(z) Core Height W(z) (ft) (fW) 0.000 1.222 6.140 1.143 0.140 1.221 6.279 1.151 0.279 1.226 6.419 1.159 0.419 1.238 6.558 1.166 0.558 1.253 6.698 1.173 0.698 1.259 6.837 1.179 0.837 1.256 6.977 1.185 0.977 1.251 7.116 1.190 1.116 1.245 7.256 1.194 1.256 1.237 7.395 1.198 1.395 1.228 7.535 1.201 1.535 1.218 7.674 1.203 1.674 1.208 7.814 1.204 1.814 1.196 7.953 1.204 1.953 1.185 8.093 1.204 2.093 1.173 8.233 1.203 2.233 1.161 8.372 1.201 2.372 1.149 8.512 1.198 2.512 1.137 8.651 1.192 2.651 1.125 8.791 1.188 2.791 1.112 8.930 1.186 2.930 1.102 9.070 1.187 3.070 1.095 9.209 1.188 3.209 1.091 9.349 1.191 3.349 1.091 9.488 1.193 3.488 1.090 9.628 1.193 3.628 1.090 9.767 1.194 3.767 1.091 9.907 1.196 3.907 1.092 10.046 1.201 4.046 1.094 10.186 1.206 4.186 1.095 10.326 1.211 4.326 1.096 10.465 1.215 4.465 1.097 10.605 1.217 4.605 1.098 10.744 1.219 4.744 1.099 10.884 1.220 4.884 1.101 11.023 1.222 5.023 1.103 11.163 1.224 5.163 1.104 11.302 1.225 5.302 1.106 11.442 1.222 5.442 1.109 11.581 1.208 5.581 1.113 11.721 1.192 5.721 1.118 11.860 1.179 5.860 1.125 12.000 1.167 6.000 1.134 11 Revision 0
V. C. Summer Cycle 17 November 2006 Table 2. RAOC W(z) at 3000 MWD/MTU V. C. Summer - Cycle 17 Core Height W(z) Core Height W(z) (ft) (ft) 0.000 1.266 6.140 1.114 0.140 1.265 6.279 1.123 0.279 1.269 6.419 1.131 0.419 1.278 6.558 1.138 0.558 1.289 6.698 1.145 0.698 1.293 6.837 1.152 0.837 1.288 6.977 1.158 0.977 1.282 7.116 1.164 1.116 1.275 7.256 1.169 1.256 1.266 7.395 1.173 1.395 1.256 7.535 1.177 1.535 1.244 7.674 1.180 1.674 1.232 7.814 1.182 1.814 1.219 7.953 1.184 1.953 1.205 8.093 1.185 2.093 1.192 8.233 1.186 2.233 1.177 8.372 1.185 2.372 1.164 8.512 1.183 2.512 1.150 8.651 1.179 2.651 1.136 8.791 1.178 2.791 1.121 8.930 1.178 2.930 1.110 9.070 1.185 3.070 1.103 9.209 1.194 3.209 1.099 9.349 1.204 3.349 1.097 9.488 1.213 3.488 1.098 9.628 1.222 3.628 1.097 9.767 1.230 3.767 1.097 9.907 1.237 3.907 1.097 10.046 1.242 4.046 1.097 10.186 1.248 4.186 1.097 10.326 1.257 4.326 1.096 10.465 1.267 4.465 1.096 10.605 1.276 4.605 1.095 10.744 1.283 4.744 1.093 10.884 1.290 4.884 1.092 11.023 1.295 5.023 1.090 11.163 1.299 5.163 1.089 11.302 1.302 5.302 1.089 11.442 1.301 5.442 1.089 11.581 1.292 5.581 1.090 11.721 1.279 5.721 1.092 11.860 1.268 5.860 1.097 12.000 1.257 6.000 1.104 12 Revision 0
V. C. Summer Cycle 17 November 2006 Table 3. RAOC W(z) at 10000 MWD/MTU V. C. Summer - Cycle 17 Core Height W(z) Core Height W(z) (fi) W_ z) _(ft) W_ z) 0.000 1.242 6.140 1.119 0.140 1.240 6.279 1.129 0.279 1.244 6.419 1.139 0.419 1.252 6.558 1.147 0.558 1.263 6.698 1.155 0.698 1.266 6.837 1.163 0.837 1.262 6.977 1.170 0.977 1.256 7.116 1.177 1.116 1.250 7.256 1.183 1.256 1.241 7.395 1.188 1.395 1.230 7.535 1.192 1.535 1.219 7.674 1.196 1.674 1.207 7.814 1.199 1.814 1.194 7.953 1.201 1.953 1.180 8.093 1.202 2.093 1.166 8.233 1.203 2.233 1.152 8.372 1.203 2.372 1.139 8.512 1.201 2.512 1.125 8.651 1.198 2.651 1.111 8.791-1.195 2.791 1.098 8.930 1.195 2.930 1.086 9.070 1.197 3.070 1.076 9.209 1.201 3.209 1.069 9.349 1.206 3.349 1.070 9.488 1.209 3.488 1.070 9.628 1.212 3.628 1.071 9.767 1.220 3.767 1.073 9.907 1.231 3.907 1.075 10.046 1.241 4.046 1.076 10.186 1.250 4.186 1.078 10.326 1.259 4.326 1.080 10.465 1.267 4.465 1.081 10.605 1.274 4.605 1.083 10.744 1.281 4.744 1.084 10.884 1.286 4.884 1.085 11.023 1.290 5.023 1.086 11.163 1.292 5.163 1.086 11.302 1.294 5.302 1.086 11.442 1.292 5.442 1.087 11.581 1.282 5.581 1.089 11.721 1.269 5.721 1.093 11.860 1.258 5.860 1.099 12.000 1.247 6.000 1.108 13 Revision 0
V. C. Summer Cycle 17 November 2006 Table 4. RAOC W(z) at 20000 MWD/MTU V. C. Summer - Cycle 17 Core Height W(z) Core Height W(z) (W)) Wft) 0.000 1.195 6.140 1.192 0.140 1.192 6.279 1.201 0.279 1.197 6.419 1.209 0.419 1.207 6.558 1.216 0.558 1.222 6.698 1.222 0.698 1.228 6.837 1.227 0.837 1.227 6.977 1.232 0.977 1.224 7.116 1.235 1.116 1.220 7.256 1.237 1.256 1.213 7.395 1.239 1.395 1.206 7.535 1.239 1.535 1.197 7.674 1.238 1.674 1.188 7.814 1.236 1.814 1.178 7.953 1.234 1.953 1.169 8.093 1.230 2.093 1.158 8.233 1.225 2.233 1.148 8.372 1.219 2.372 1.137 8.512 1.213 2.512 1.127 8.651 1.205 2.651 1.116 8.791 1.196 2.791 1.105 8.930 1.188 2.930 1.096 9.070 1.180 3.070 1.090 9.209 1.177 3.209 1.088 9.349 1.178 3.349 1.091 9.488 1.180 3.488 1.094 9.628 1.183 3.628 1.097 9.767 1.188 3.767 1.100 9.907 1.194 3.907 1.102 10.046 1.200 4.046 1.105 10.186 1.205 4.186 1.110 10.326 1.210 4.326 1.115 10.465 1.214 4.465 1.120 10.605 1.218 4.605 1.125 10.744 1.221 4.744 1.129 10.884 1.223 4.884 1.134 11.023 1.226 5.023 1.137 11.163 1.228 5.163 1.140 11.302 1.224 5.302 1.141 11.442 1.217 5.442 1.144 11.581 1.203 5.581 1.151 11.721 1.187 5.721 1.161 11.860 1.173 5.860 1.172 12.000 1.162 6.000 1.182 14 Revision 0
V. C. Summer Cycle 17 November 2006 Table 5. RAOC FQ Margin Decreases in Excess of 2% Per 31 EFPD - Cycle 17 Maximum Cycle Burnup Decrease (MWD/MTU) in Fe Margin 665 1.0200 837 1.0222 1008 1.0221 1180 1.0201 1351 1.0200 Note: All cycle burnups outside the range of this table shall use a 1.020 decrease in margin for compliance with Specification 4.2.2.2e. Linear interpolation is adequate for intermediate cycle burnups. 15 Revision 0
V. C. Summer Cycle 17 November 2006 Table 6. Baseload W(z) at 150 MWD/MTU V. C. Summer - Cycle 17 Core Height W(z) Core Height W(z) (ft) (ft) 0.000 1.113 6.140 1.062 0.140 1.114 6.279 1.060 0.279 1.114 6.419 1.058 0.419 1.116 6.558 1.056 0.558 1.117 6.698 1.056 0.698 1.118 6.837 1.056 0.837 1.117 6.977 1.056 0.977 1.117 7.116 1.057 1.116 1.116 7.256 1.059 1.256 1.115 7.395 1.062 1.395 1.114 7.535 1.063 1.535 1.113 7.674 1.065 1.674 1.112 7.814 1.067 1.814 1.110 7.953 1.069 1.953 1.108 8.093 1.070 2.093 1.107 8.233 1.072 2.233 1.105 8.372 1.073 2.372 1.102 8.512 1.075 2.512 1.100 8.651 1.076 2.651 1.098 8.791 1.078 2.791 1.095 8.930 1.079 2.930 1.092 9.070 1.080 3.070 1.090 9.209 1'.081 3.209 1.087 9.349 1.082 3.349 1.084 9.488 1.083 3.488 1.082 9.628 1.085 3.628 1.080 9.767 1.085 3.767 1.079 9.907 1.086 3.907 1.078 10.046 1.087 4.046 1.077 10.186 1.088 4.186 1.075 10.326 1.089 4.326 1.074 10.465 1.090 4.465 1.073 10.605 1.091 4.605 1.072 10.744 1.091 4.744 1.071 10.884 1.092 4.884 1.071 11.023 1.093 5.023 1.070 11.163 1.093 5.163 1.070 11.302 1.094 5.302 1.069 11.442 1.094 5.442 1.068 11.581 1.094 5.581 1.067 11.721 1.093 5.721 1.066 11.860 1.093 5.860 1.064 12.000 1.094 6.000 1.063 16 Revision 0
V. C. Summer Cycle 17 November 2006 Table 7. Baseload W(z) at 3000 MWD/MTU V. C. Summer - Cycle 17 Core Height W(z) Core Height W(z) (ft) (ft) 0.000 1.095 6.140 1.056 0.140 1.096 6.279 1.055 0.279 1.097 6.419 1.054 0.419 1.098 6.558 1.052 0.558 1.100 6.698 1.050 0.698 1.101 6.837 1.048 0.837 1.102 6.977 1.047 0.977 1.102 7.116 1.048 1.116 1.102 7.256 1.050 1.256 1.102 7.395 1.052 1.395 1.102 7.535 1.054 1.535 1.102 7.674 1.056 1.674 1.102 7.814 1.058 1.814 1.101 7.953 1.060 1.953 1.101 8.093 1.062 2.093 1.100 8.233 1.064 2.233 1.099 8.372 1.066 2.372 1.098 8.512 1.067 2.512 1.097 8.651 1.069 2.651 1.096 8.791 1.071 2.791 1.094 8.930 1.073 2.930 1.093 9.070 1.074 3.070 1.091 9.209 1.076 3.209 1.090 9.349 1.077 3.349 1.088 9.488 1.079 3.488 1.086 9.628 1.081 3.628 1.084 9.767 1.082 3.767 1.082 9.907 1.083 3.907 1.080 10.046 1.085 4.046 1.079 10.186 1.086 4.186 1.078 10.326 1.087 4.326 1.077 10.465 1.089 4.465 1.075 10.605 1.090 4.605 1.074 10.744 1.091 4.744 1.073 10.884 1.092 4.884 1.071 11.023 1.093 5.023 1.069 11.163 1.094 5.163 1.068 11.302 1.095 5.302 1.066 11.442 1.096 5.442 1.064 11.581 1.096 5.581 1.062 11.721 1.095 5.721 1.060 11.860 1.096 5.860 1.058 12.000 1.096 6.000 1.057 -1 1 17 Revision 0
V. C. Summer Cycle 17 November 2006 Table 8. Baseload W(z) at 10000 MWD/MTU V. C. Summer - Cycle 17 Core Height W(z) Core Height W(z) (ft) (ft) 0.000 1.107 6.140 1.060 0.140 1.108 6.279 1.058 0.279 1.109 6.419 1.055 0.419 1.110 6.558 1.053 0.558 1.111 6.698 1.053 0.698 1.112 6.837 1.053 0.837 1.113 6.977 1.052 0.977 1.113 7.116 1.054 1.116 1.113 7.256 1.056 1.256 1.113 7.395 1.058 1.395 1.112 7.535 1.060 1.535 1.112 7.674 1.062 1.674 1.111 7.814 1.064 1.814 1.110 7.953 1.065 1.953 1.109 8.093 1.067 2.093 1.108 8.233 1.068 2.233 1.106 8.372 1.070 2.372 1.104 8.512 1.071 2.512 1.103 8.651 1.073 2.651 1.101 8.791 1.074 2.791 1.098 8.930 1.075 2.930 1.096 9.070 1.076 3.070 1.093 9.209 1.077 3.209 1.091 9.349 1.078 3.349 1.088 9.488 1.079 3.488 1.085 9.628 1.080 3.628 1.083 9.767 1.081 3.767 1.081 9.907 1.082 3.907 1.080 10.046 1.083 4.046 1.078 10.186 1.084 4.186 1.077 10.326 1.085 4.326 1.076 10.465 1.086 4.465 1.075 10.605 1.087 4.605 1.074 10.744 1.088 4.744 1.073 10.884 1.088 4.884 1.072 11.023 1.089 5.023 1.071 11.163 1.090 5.163 1.070 11.302 1.090 5.302 1.069 11.442 1.091 5.442 1.068 11.581 1.091 5.581 1.066 11.721 1.091 5.721 1.065 11.860 1.091 5.860 1.063 12.000 1.091 6.000 1.062 18 Revision 0
V. C. Summer Cycle 17 November 2006 Table 9. Baseload W(z) at 20000 MWD/MTU V. C. Summer - Cycle 17 Core Height W(z) Core Height W(z) (ft) (ft) 0.000 1.142 6.140 1.062 0.140 1.143 6.279 1.062 0.279 1.144 6.419 1.064 0.419 1.145 6.558 1.067 0.558 1.146 6.698 1.069 0.698 1.146 6.837 1.070 0.837 1.146 6.977 1.072 0.977 1.145 7.116 1.073 1.116 1.144 7.256 1.074 1.256 1.142 7.395 1.075 1.395 1.140 7.535 1.076 1.535 1.138 7.674 1.077 1.674 1.135 7.814 1.078 1.814 1.132 7.953 1.078 1.953 1.129 8.093 1.079 2.093 1.125 8.233 1.079 2.233 1.121 8.372 1.079 2.372 1.117 8.512 1.079 2.512 1.113 8.651 1.082 2.651 1.108 8.791 1.086 2.791 1.103 8.930 1.089 2.930 1.097 9.070 1.092 3.070 1.092 9.209 1.095 3.209 1.087 9.349 1.098 3.349 1.083 9.488 1.101 3.488 1.082 9.628 1.104 3.628 1.080 9.767 1.106 3.767 1.079 9.907 1.109 3.907 1.077 10.046 1.111 4.046 1.076 10.186 1.113 4.186 1.074 10.326 1.114 4.326 1.072 10.465 1.116 4.465 1.071 10.605 1.117 4.605 1.070 10.744 1.118 4.744 1.069 10.884 1.118 4.884 1.068 11.023 1.119 5.023 1.067 11.163 1.119 5.163 1.067 11.302 1.119 5.302 1.066 11.442 1.119 5.442 1.065 11.581 1.117 5.581 1.064 11.721 1.116 5.721 1.062 11.860 1.115 5.860 1.061 12.000 1.115 6.000 1.061 19 Revision 0
V. C. Summer Cycle 17 November 2006 Table 10. Baseload FQ Margin Decreases in Excess of 2% Per 31 EFPD - Cycle 17 Maximum Cycle Burnup Decrease (MWD/MTU) in FO Margin 665 837 1008 1180 1351 1523 1695 1866 2038 2210 2381 2553 2724 2896 3068 3239 3411 3583 3754 1.0200 1.0266 1.0313 1.0313 1.0304 1.0296 1.0291 1.0293 1.0303 1.0317 1.0333 1.0346 1.0348 1.0337 1.0314 1.0282 1.0248 1.0216 1.0200 Note: All cycle burnups outside the range of this table shall use a 1.020 decrease in margin for compliance with Specification 4.2.2.4e. Linear interpolation is adequate for intermediate cycle burnups. 20 Revision 0
V. C. Summer Cycle 17 November 2006 30.0 29.8 29.6 29.4 0 29.2 29.0 0 r 2 29.0 0 S28.8 28.6 28.4 28.2 28.0 Figure 5. RCS Total Flowrate vs. R for Three Loop Operation V. C. Summer - Cycle 17 T - - i T - I-I - II - --I-- T - --r T "1 - -I I - - I - - I T S-I I F I I I I I I I I I I I I I I-H ---H----- I I I F I I I F F I I F F I I I 4- ~- - --- 4-I - T- -- - -I - -I-i I I J I T I -I - I Ij--- - -I - I I -I iii t-------t----t-- .0---t-----28.36)-2--- j---------F I I1 T _I-I - I -I I T I T T "1 F F F F F F I I I F I I I F F I F F T 1 I
- T 1
F "3 -I- -I- "I T I i T - -I--F --H-I--4--H----F-- -+f---....----F---+- IH... I----I-I- 4 F I .III I__ I F F 4 -I-L --1-- J --I---- -I I. .H -J -{- F F Aceptable Operation F F', uncepale F F F Region F F F F F' F. F.F F.F F Operation Region F F F F F F F F FJ I 1 T " F IF F F F F F IF~ T I -I I-T I ~~ F FrT 1 1 F" F + -- *-I---F--I. + --- I H F F F F F F F F F F F I I I I I-I I I I_ I i_ I A I I i in i n I FI F I F F F F F F F F F F F F F F I F F FI F F F F F F F F F F F F F F F F Fi F F F F F F F F --- F- +/----I- +/-- -H- -+- -H "I-- - F I F F F F F F F F F F F F F F 0.90 0.95 1.00 1.05 1.10 R = FN-delta-H/1.62[1.0 + 0.3(1.0 - P)] Measurement Uncertainty of 2.1% for Flow (includes 0.1% for feedwater venturi fouling) is included in this figure. 21 Revision 0}}