ML063110232
| ML063110232 | |
| Person / Time | |
|---|---|
| Site: | Indian Point (DPR-026, DPR-064) |
| Issue date: | 11/07/2006 |
| From: | Collins S Region 1 Administrator |
| To: | Dacimo F Entergy Nuclear Operations |
| References | |
| Download: ML063110232 (4) | |
Text
November 7, 2006 Mr. Fred Dacimo Site Vice President Entergy Nuclear Operations, Inc.
Indian Point Energy Center 295 Broadway, Suite 1 P.O. Box 249 Buchanan, NY 10511-0249
SUBJECT:
ACKNOWLEDGMENT OF ENTERGY NUCLEAR OPERATIONS, INC CORRECTIVE ACTIONS FOR INDIAN POINT PUBLIC ALERT NOTIFICATION SYSTEM
Dear Mr. Dacimo:
We have received and reviewed your letters of October 18 and 20, 2006, which document your commitments to improve the reliability of the Indian Point Public Alert Notification System (ANS). These actions had been previously discussed at a meeting between Entergy and the NRC that was open for public observation on October 6, 2006. We acknowledge your commitments and will continue to provide enhanced inspection oversight of your actions to maintain the ANS as described in our letter to you dated November 23, 2005.
In accordance with 10 CFR 2.790 of the NRCs "Rules of Practice," a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of the NRC document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html Should you have any questions regarding this report, please contact Mr. Raymond Lorson of my staff at 610-337-5282.
Sincerely,
/RA/
Samuel J. Collins Regional Administrator
Enclosures:
- 1. Letter from Entergy dated 10/18/06 re Corrective Action for IP Public Alert Notification System
- 2. Letter from Entergy dated 10/20/06 re Corrective Action for IP Public Alert Notification System Docket Nos.
50-247, 50-286 License Nos. DPR-26, DPR-64
F. Dacimo 2
cc w/encls:
G. J. Taylor, Chief Executive Officer, Entergy Operations M. R. Kansler, President, Entergy Nuclear Operations Inc. (ENO)
J. T. Herron, Senior Vice President and Chief Operations Officer (ENO)
C. Schwarz, Vice President, Operations Support (ENO)
P. Rubin, General Manager Operations (ENO)
O. Limpias, Vice President, Engineering (ENO)
J. McCann, Director, Licensing (ENO)
C. D. Faison, Manager, Licensing (ENO)
M. J. Colomb, Director of Oversight (ENO)
J. Comiotes, Director, Nuclear Safety Assurance (ENO)
P. Conroy, Manager, Licensing (ENO)
T. C. McCullough, Assistant General Counsel, Entergy Nuclear Operations, Inc.
P. R. Smith, President, New York State Energy, Research and Development Authority P. Eddy, Electric Division, New York State Department of Public Service Assistant General Counsel, Entergy Nuclear Operations, Inc.
C. Donaldson, Esquire, Assistant Attorney General, New York Department of Law D. ONeill, Mayor, Village of Buchanan J. G. Testa, Mayor, City of Peekskill R. Albanese, Four County Coordinator S. Lousteau, Treasury Department, Entergy Services, Inc.
Chairman, Standing Committee on Energy, NYS Assembly Chairman, Standing Committee on Environmental Conservation, NYS Assembly Chairman, Committee on Corporations, Authorities, and Commissions M. Slobodien, Director, Emergency Planning B. Brandenburg, Assistant General Counsel Assemblywoman Sandra Galef, NYS Assembly County Clerk, Westchester County Legislature A. Spano, Westchester County Executive R. Bondi, Putnam County Executive C. Vanderhoef, Rockland County Executive E. A. Diana, Orange County Executive T. Judson, Central NY Citizens Awareness Network M. Elie, Citizens Awareness Network D. Lochbaum, Nuclear Safety Engineer, Union of Concerned Scientists Public Citizen's Critical Mass Energy Project M. Mariotte, Nuclear Information & Resources Service F. Zalcman, Pace Law School, Energy Project L. Puglisi, Supervisor, Town of Cortlandt Congresswoman Sue W. Kelly Congresswoman Nita Lowey Senator Hillary Rodham Clinton Senator Charles Schumer J. Riccio, Greenpeace A. Matthiessen, Executive Director, Riverkeeper, Inc.
M. Kaplowitz, Chairman of County Environment & Health Committee A. Reynolds, Environmental Advocates M. Jacobs, Director, Longview School D. Katz, Executive Director, Citizens Awareness Network
F. Dacimo 3
cc w/encls (continued):
P. Leventhal, The Nuclear Control Institute K. Coplan, Pace Environmental Litigation Clinic W. DiProfio, PWR SRC Consultant D. C. Poole, PWR SRC Consultant W. Russell, PWR SRC Consultant W. Little, Associate Attorney, NYSDEC V. Quinn, Homeland Security R. Thomson, FEMA
F. Dacimo 4
Distribution:
(Via E-mail)
S. Collins, RA M. Dapas, DRA B. Sosa, RI OEDO R. Laufer, NRR J. Boska, PM, NRR P. Milano, PM (backup)
E. Cobey, DRP D. Jackson, DRP C. Long, DRP M. Cox, DRP, Senior Resident Inspector - Indian Point 2 G. Bowman, DRP, Acting Senior Resident Inspector - Indian Point 2 B. Wittick, Resident Inspector - Indian Point 3 R. Martin, DRP, Resident OA A. Blough, DRS M. Gamberoni, DRS R. Lorson, DRS SUNSI Review Complete: RKL (Reviewers Initials)
DOCUMENT NAME: C:\\FileNet\\ML063110232.wpd After declaring this document An Official Agency Record it will be released to the Public.
To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy OFFICE RI/DRS RI/DRS RI/RA NAME RLorson (RKL)
ABlough (ARB)
SCollins (SJC)
DATE 10/28/06 10/31/06 11/06/06 OFFICE RI/DRP RI/DRP NAME ECobey (DEJ for)* DLew (BEH for)
DATE 10/26/06 10/26/06 OFFICIAL RECORD COPY