Yankee Nuclear Power Station - Attachment B Data Quality Assessment Plots and Curves, Figures 1 NOL-05-01 Through 10 NOL-05-02
ML062970069
Person / Time
Site: Yankee Rowe
(DPR-003)
Issue date: 10/05/2006
From:
Yankee Atomic Electric Co
To:
NRC/FSME
References
Download: ML062970069 (7)


Text

NOL-05 Attachment B Data Quality Assessment Plots and Curves Attachment B Data Quality Assessment Plots and Curves List of Figures Figure________________________________________________________________Page FIGURE 1 NOL-05-01 PROSPECTIVE POWER CURVE...........................................................................................2 FIGURE 2 NOL-05-01 RETROSPECTIVE POWER CURVE.......................................................................................2 FIGURE 3 NOL-05-01SUM OF FRACTIONS SCATTER PLOT..................................................................................3 T

FIGURE 4 NOL-05-01 SUM OF FRACTIONS QUANTILE PLOT...............................................................................3 FIGURE 5 NOL-05-01 SUM OF FRACTIONS FREQUENCY PLOT............................................................................4 T

FIGURE 6 NOL-05-02 PROSPECTIVE POWER CURVE...........................................................................................5 FIGURE 7 NOL-05-02 RETROSPECTIVE POWER CURVE.......................................................................................5 FIGURE 8 NOL-05-02 SUM OF FRACTIONS SCATTER PLOT.................................................................................6 T

FIGURE 9 NOL-05-02 SUM OF FRACTIONS QUANTILE PLOT...............................................................................6 FIGURE 10 NOL-05-02 SUM OF FRACTIONS FREQUENCY PLOT..........................................................................7 T

The LBGR on the Power Curves have been adjusted to demonstrate the actual power of the survey.

1

NOL-05 Attachment B Data Quality Assessment Plots and Curves Figure 1 NOL-05-01 Prospective Power Curve Figure 2 NOL-05-01 Retrospective Power Curve 2

NOL-05 Attachment B Data Quality Assessment Plots and Curves Figure 3 NOL-05-01Sum of Fractions Scatter Plot NOL-05-01 Sample Results Scatter Plot DCGLw = 1 SOF

  • 0.08
  • 0.21
  • -0.06

-0.1

-0.05 0

0.05 0.1 0.15 0.2 0.25 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 Activity Average

"+3StDev"

"-3StDev" Figure 4 NOL-05-01 Sum of Fractions Quantile Plot NOL-05-01 Sample Results Quantile Plot 0.06 0

0.05 0.1 0.15 0.2 0.25 0

10 20 30 40 50 60 70 80 90 100 Percentile Activity (SOF)

Direct Measurements median 75th Percentile 50th Percentile 3

NOL-05 Attachment B Data Quality Assessment Plots and Curves Figure 5 NOL-05-01 Sum of Fractions Frequency Plot NOL-05-01 Frequency Plot 0

1 2

3 4

5 6

7 8

0.03 0.05 0.07 0.09 0.11 0.14 0.16 0.18 0.2 0.22 Bin Upper End Value (SOF)

Number of Observations 4

NOL-05 Attachment B Data Quality Assessment Plots and Curves Figure 6 NOL-05-02 Prospective Power Curve Figure 7 NOL-05-02 Retrospective Power Curve 5

NOL-05 Attachment B Data Quality Assessment Plots and Curves Figure 8 NOL-05-02 Sum of Fractions Scatter Plot NOL-05-02 Sample Results Scatter Plot DCGLw = 1 SOF

  • 0.15
  • 0.49
  • -0.19

-0.3

-0.2

-0.1 0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Activity Average

"+3StDev"

"-3StDev" Figure 9 NOL-05-02 Sum of Fractions Quantile Plot NOL-05-02 Sample Results Quantile Plot 0.11 0

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0

10 20 30 40 50 60 70 80 90 100 Percentile Activity (SOF)

Direct Measurements median 75th Percentile 50th Percentile 6

NOL-05 Attachment B Data Quality Assessment Plots and Curves Figure 10 NOL-05-02 Sum of Fractions Frequency Plot NOL-05-02 Frequency Plot 0

2 4

6 8

10 12 14 16 0.05 0.11 0.17 0.23 0.29 0.34 0.4 0.46 0.52 0.58 Bin Upper End Value (SOF)

Number of Observations 7