October 23, 2006 Florida Power and Light Company ATTN: Mr. J. A. Stall, Senior Vice President Nuclear and Chief Nuclear Officer P. O. Box 14000 Juno Beach, FL 33408-0420

SUBJECT:

PUBLIC MEETING

SUMMARY

- CATEGORY ONE REGULATORY CONFERENCE MEETING - TURKEY POINT NUCLEAR PLANT, DOCKET NO.

05000250

Dear Mr. Stall :

This refers to the Regulatory Conference meeting conducted at your request at the Region II Office in Atlanta, Georgia on October 10, 2006. The purpose of the meeting was to discuss Turkey Point Unit 3 loss of residual heat removal event on March 8, 2006. Note that the briefing materials presented by Florida Power and Light Company (FPL) contained some FPL proprietary information. Enclosed are a list of attendees and FPLs non-proprietary version of presentation slides.

The discussions focused on the following topics: An overview of the event, Event Description, Corrective actions, Thermal Hydraulic Analysis of Event, Mitigating Actions, and SDP Analysis.

During the conference, Florida Power and Light Company (FPL) agreed that a violation of NRC requirements occurred and stated that corrective actions have been taken to prevent recurrence. FPL also stated that their SDP evaluation concluded that the change in core damage frequency for this event is less than 1.0E-6/yr. FPL committed to submit additional technical information to NRC for review. Results of NRCs review and decision will be discussed in Inspection Report 05000250/2006016.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

CP&L 2

Should you have any questions concerning this meeting, please contact Mr. Son Ninh at (404) 562-4532.

Sincerely,

\\RA\\

Joel T. Munday Reactor Projects Branch 3 Division of Reactor Projects Docket No.:

50-250 License No:

DPR-31

Enclosure:

1. List of Attendees
2. Licensees Presentation Slides

ML062960408 OFFICE RII:DRP SIGNATURE SON NAME SNinh DATE 10/20/2006 10/ /2006 10/ /2006 10/ /2006 10/ /2006 10/ /2006 10/ /2006 E-MAIL COPY?

YES NO YES NO YES NO YES NO YES NO YES NO YES NO

CP&L 3

cc w/encl:

T. O. Jones Site Vice President Turkey Point Nuclear Plant Florida Power and Light Company Electronic Mail Distribution James Connolly Licensing Manager Turkey Point Nuclear Plant Florida Power and Light Company Electronic Mail Distribution Becky Ferrare Licensing Department Administrator Turkey Point Nuclear Plant Florida Power and Light Company Electronic Mail Distribution Michael O. Pearce Plant General Manager Turkey Point Nuclear Plant Florida Power and Light Company Electronic Mail Distribution William E. Webster, Vice President Nuclear Operations Florida Power & Light Company Electronic Mail Distribution Mark Warner, Vice President Nuclear Operations Support Florida Power & Light Company Electronic Mail Distribution Rajiv S. Kundalkar Vice President - Nuclear Engineering Florida Power & Light Company Electronic Mail Distribution M. S. Ross, Managing Attorney Florida Power & Light Company Electronic Mail Distribution Marjan Mashhadi, Senior Attorney Florida Power & Light Company Electronic Mail Distribution Attorney General Department of Legal Affairs The Capitol Tallahassee, FL 32304 William A. Passetti Bureau of Radiation Control Department of Health Electronic Mail Distribution Alejandro Sera Miami-Dade County Emergency Management Coordinator Electronic Mail Distribution County Manager Metropolitan Dade County 111 NW 1st Street, 29th Floor Miami, FL 33128 Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs Electronic Mail Distribution Curtis Ivy City Manager of Homestead Electronic Mail Distribution Distribution w/encl: (See page 3)

CP&L 4

Letter to Mr. J. A. Stall from Joel T. Munday dated October 23, 2006.

SUBJECT:

PUBLIC MEETING

SUMMARY

- CATEGORY ONE REGULATORY CONFERENCE MEETING - TURKEY POINT NUCLEAR PLANT, DOCKET NO.

05000250 Distribution w/encl:

B. Moroney, NRR C. Evans (Part 72 Only)

L. Slack, RII EICS OE Mail (email address if applicable)

RIDSNRRDIRS PUBLIC

LIST OF ATTENDEES Nuclear Regulatory Commission W. Travers, Regional Administrator, Region II (RII)

C. Casto, Director, Division of Reactor Projects (DRP), RII J. Shea, Director, Division of Reactor Safety (DRS), RII J. Munday, Chief, Reactor Projects Branch 3, DRP, RII M. Ernstes, Chief, Reactor Project Branch 1, DRP, RII S. Stewart, Senior Resident Inspector, Turkey Point W. Rogers, Senior Reactor Analyst, DRS, RII S. Sparks, Senior Enforcement Specialist, EICS, RII D. Solorio, Section Chief, Enforcement Policy and Program Oversight Section, Office of Enforcement (OE)

L. Trocine, Senior Enforcement Specialist, OE M. Franovich, Chief, PRA Operational Support & Maintenance Branch, Office of Nuclear Reactor Regulation (NRR)

M. Pohida, Senior Reactor Analyst, NRR S. Crane, NRR M. Vaaler, NRR NRC (via teleconference)

B. Moroney, NRR S. Wong, Senior Reactor Analyst, NRR J. Kramer, NRR J. Circle, NRR R. Pascarelli, NRR A. Zoulis, NRR J. Mitman, RES Florida Power and Light Company J. Stall, Chief Nuclear Officer, FPL T. Jones, Site Vice President, Turkey Point R. Kundalkar, Vice President, Nuclear Engineering, Juno Beach M. Pearce, Plant Manager, Turkey Point S. Greenlee, Engineering Manager, Turkey Point J. Garcia, Reliability Risk Management Manager, Juno Beach C. Guey, Supervisor, Reliability Risk Management, Juno Beach J. Connolly, Licensing Manager, Turkey Point M. Ross, Associate General Counsel, Juno Beach M. Pope, Numerical Applications, Inc.

T. Timmons, Westinghouse D. True, ERIN