Discharge Monitoring Report for September 2006
ML062850071
Person / Time
Site: Sequoyah  
Issue date: 10/05/2006
From: Douet J, Howard S
Tennessee Valley Authority
To: Hannah C
Office of Nuclear Reactor Regulation, State of TN, Dept of Environment & Conservation, Div of Water Pollution Control
References
TN0026450
Download: ML062850071 (13)


Text

Tennessee Valley Authority, Post Off ice Box 2000, Soddy-Daisy, Tennessee 37384-2000 October 5, 2006 State of Tennessee Department of Environment and Conservation Division of Water Pollution Control Enforcement & Compliance Section 6t1h Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534 Attention: Mr. Chip Hannah

Dear Mr. Hannah:

SEQUOYAH NUCLEAR PLANT - DISCHARGE MONITORING REPORT FOR SEPTEMBER 2006 Enclosed is the September 2006 Discharge Monitoring Report for Sequoyah Nuclear Plant.

Please contact me at (423) 843-6700 if you have any questions or comments.

Sincerely, Stephanie A. Howard Principal Environmental Engineer Signatory Authority for J. Randy Douet Site Vice President Sequoyah Nuclear Plant Enclosure cc (Enclosure):

Chattanooga Environmental Assistance Center Division of Water Pollution Control State Office Building, Suite 550 540 McCallie Avenue Chattanooga, Tennessee 37402-2013 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Primed n recycWd moe.

PERMITTEE NAME/ADDRESS (Include Facility Nameltocat ion if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 SODDY.- DAISY TN 37384

Faitv, TVA - SEOUOYAH NUCLEAR PLANT_

Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

SB01 TN065 1

0 F -FINAL PERMIT NUMBER IDISCHARGE NUMBER DIFFUSER DISCHARGE Form Approved.

0MB No. 2040-0004 MONTR "NIG ~JQ EFFLUENT YERMO DAMY PFDMO DAY

    • N ICAG 7*

From 06 091 01 To 170 01..N ICAG PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION No.

FREQUENCY SAMPLE

_____EX OF TYPE

> <AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.

SAMPLE

    • 30.1 04 0

30/30 MODELD CENTIGRADE MEASUREMENT 00010 Z

0 0

PEMT7 30.5 DEG.C.

SEEý CK REQ INSTREAM MONITORING RQIEET

,~.....______

DIYM EMT TEMPERATURE, WATER DEG.

SAMPLE

    • 43.0 04 0

30/30 RCORDR CENTIGRADE MEASUREMENT 000`10 1

0 0

7-. PERMIT,.-:,-

        • kh***

,:.****~~-~-~****T EOT DG.SE C

E EFFLUENT GROSS VALUE

.E.U...E

.K...DIY MX PERMIT.

TEMP. DIFF. BETWEEN SAMP. &

SAMPLE

    • 2.8 04 0

30/30 CALCTD UPSTRM DEG.C MEASUREMENT 00016 1

S 0

".ER"~

-3..i*****z7 DEG.C.

CONTIN CALCTD REQUIREMENT"ý.

AIYM.

___UU EFFLUENT GROSS VALUE UOUS*

PH SAMPLE 7.5 7.6 12 0

5 /30 GRAB MEASUREMENT`1 100400 1

0 0

'ý:PERMIT.-

      • --****.>-_6.0

-9.0 SU WEEKLY.

GRAB 1EFFLUENT GROSS VALUE

.EURMN MINIMUM.-,.

-.<MAXIMUM:

SOLIDS, TOTAL SUSPENDED SAMPLE

    • 6 6

19 0

1 /30 GRAB MEASUREMENT 00530 1

0 0

PERMIT:%_-- -,'3 0

MI ONHYGA EFFLUENT GROSS VALUE REOUIREMENT'ý MO'AVG

-DAILY MX OIL AND GREASE SAMPLE

  • <5

<5 19 0 1/30 GRAB MEASUREMENT 1

0056 1

0

0.

E~REMI 15~'

20: -

MG1L MONTHLY GRAB EFFLUENT GROSS VALUE RQIENT_____MOAG DAILY MX FLOW, IN CONDUIT OR THRU SAMPLE 1624 03 0

30/30 RCORDR TREATMENT PLANT MEASUREMENT 50050 1

0 0

PERMIT, REO:

MGD

.L

.ý CTI RCRD "RPR-G

.7-CONT.....D EFFLUENT GROSS VALUE 4:EUREETDAILY-NMX.

-UOUS NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my I-.

TELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnelj J. Randy DoUet properly gather and evaluate the information submitted. Based on my inquiry of the person or Io StViePeietinformation, the information submitted is. to the best of my knowledge and belief, true, PrincipalEnviron entalEngineer_42_843-6700_06_10_0 Sit VcePreidntaccurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVEI information. including the possibility of fine and imprisonment for knowing violations.

I OFFICER OR AUTHORIZED AGENT AREA INUMBER YEAR MO DAY TYPED OR PRINTED I ____

J__

CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No closed mode operation. The following information is included in an attachment: 1. thermal compliance information 2. CCW data' 3. veliger monitoring data EPA Form 3320-11 (REV 3199)

Previous editions may be used Page 1 of 2

September 2006 *DMR Attachment September 2006 Thermal Compliance Information September 1-30: The downstream temperature and temperature rate-of-change are based on measurements from Station 8, the "backup temperature monitor" located at the end of the mixing zone (TRM 483.4). The temperature rise is based on the increase in temperature from measurements at Station 14, located upstream of the plant (TRM 490.5), and measurements at Station 8 (TRMV 483.4). Consistent with the permit, measurements reported for the downstream temperature and the temperature rise represent daily maximum 24-hour rolling averages; and, measurements reported of the temperature rate-of-change represent 1-hour averages.

Measurements were used rather than the numerical modeling system because of relatively low river flows. TVA has learned as a result of the continuing studies performed under Part Ill.G. of the permit that under low flow conditions, adjustments may be needed in the formulation of numerical model to improve its accuracy. Until river flows increase or appropriate model adjustments can be made, the modeling system is considered "out of service".

Sep~tember 2006 CCW Data CCW TRENCH Extractable Petroleum DaterTime Collected Hydrocarbons Analysis Date/Time

,Analyst Method 09/05/2006 @ 1005 0.7 mg/L 09/09/2006 @ 0121 KRR EPA 8015 CCW CHANNEL Extractable Petroleum Date/Time Collected Hydrocarbons Analysis Date/Time Analyst Method 09/05/2006 @ 1000

<0.5 mg/L 09/09/2006 @ 0158 KRR EPA 8015 September 2006 Veli-ger Monitoring Information No samples collected the month of September 2006.

PERMITTEE NAMEJADDRESS (Include Facility Name/Location if Different)

Name TVA -SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 SODDY -DAISY TN 37384

_Facfiit TVA -SEQUOYAHINUCLEAR PLNT7 Location HAMILTON COULNTY-----------

ATTrN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

SB01 TNO02450 11 G IF -FINAL PEMTNME LDISCHARGE NMBERJ DIFFUSER DISCHARGE Form Approved.

OMB No. 2040.0004 I

KflNITO'RINC.

PFRpinnf 1EFFLUENT From 1 06 0 iol To 1 0 1 9 1 NO DISCHARGE E]..

NOTE: Read instructions before comp~leting this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE

_____EX OF TYPE

> <AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS CHLORINE, TOTAL RESIDUAL SAMPLE 0.020 0.033 19 0

25/3D GRAB MEASUREMENT 50060 1

0 0

PERMIT?.-ý_

0',

MGI WE K-:

-REQUIREMENT-bkS

~&?.

010-01 GL EKICLT EFFLUENT GROSS VALUE

-~.. i.

M AV INST MAX by TEMPERATURE - C, RATE OF SAMPLE 0.6 62 0

3/0CLT CHANGE MEASUREMENT 82234 1

0 0

. PERMIT-.'-..

in.

DEG 2

OTNCLT EFFLUENT GROSS VALUE RE-REETDAIYM C/HR

~.UU SAMPLE MEASUREMENT REQUIREMENT, SAMPLE MEASUREMENT

  • .PERMIT,,.,",.`-,.

REQUIREMENT..

SAMPLE MEASUREMENT PERMIT REQUIREMENT.'

7 SAMPLE MEASUREMENT

.,.,PERMIT REQUIREIME:NTi-SAMPLE MEASUREMENT

......PERMIT..~..-. I.... 9Kii~2.

REQUIREMENT...........,... -

~

II L:

rINUI'ALLXEUTIV OFICE NAMEITITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penally of law that this document and all attach~ments were prepared under myl ire a n -

sim in --

d-ce with -

A-gne ý to --

re ---

J. Randy Douet Site Vice President pwopet gther and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is,* to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.

4&pw~CAnc Principal Environmental Engineer SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT I

TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

The following injections occured: 1. PCL-222 Copolymer (max. calc. conc. was O.OO9mg/L-Iimit O.2mgIL) 2. PCL-222 Phosphate (max. calc. conc. was O.025mg/L-limit O.2mg/L) 3. Biodetergent 73551 (max. cabc. conc. was 0.01 5mgIL--Iimit 2.OmgIL) 4. MSW-101 (max. cale. conc. was O.Ol8mglL-limit O.2mgIL)

EPA Form 3320-1 (REV 3199)

Previous editions may be usedEPA orm33201 (EV

/99)

Preiousediion maybe sedPage 2 of 2

PERMITTEE NAME/ADDRESS (Include Facility Nameilocation if Different)

Name TVA -SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

-- SODDY - DAISY _TN 37384 FaciliýTy VA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DM1?)

(SUBR 01)

TNO02450 11 F -FINAL L

IEEMITNUMBER DICAGENME DIFFUSER DISCHARGE IMONITORING-PERIOD EFFLUENT YEAR MO DAY YEAR MO DAY NO ICAG Frm 06 07

01.

To 06SC09R30 From07 0 To06 0

3NOTE:

Read instructiont Form Approved.

OMB No. 2040-0004 EDZ..

sbefore completing this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE

____________________EX OF TYPE

> <AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS BORON, TOTAL SAMPLE

    • <0.20 19 0

2/92 MEASUREMENT 01022 1

0 0

  • -PERMIT-Z'...

EOT MGIL

QTRLY, GRA EFFLUENT GROSS VALUE

~

EURMN SAMPLE MEASUREMENT REQUIREMENT:

SAMPLE MEASUREMENT PERMIT.-;%..-

REQUIREMENT, SAMPLE MEASUREMENT REQUIREMENT.

SAMPLE MEASUREMENT

-REQUIREMENT",~-~.

SAMPLE MEASUREMENT PERMIT:-

2-

  • REQUIREMENT-SAMPLE MEASUREMENT

.PERMIT

-REQUIREMENT-NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under pernatty of law that this document and all attachimenta were prepared unde myEPON DATE'\\

direction or supervision in accordance with a system designed to assure that qualifiedprane

.j1;fj/f,1a j

().

J. Randy Douet properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Principal Environmental Engineer 42 83-70 6

10 4

SiteVicePresdentinformation. the information submitted ia, to the best of my knowledge and belief, true.

423____843-6700_____06___10__04_

Sit VcePreidntaccurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVEI information. including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA INUMBER YEAR MO DAY TYPED OR PRINTED I

CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

Boron was sampled on 07105/2006 at 0745 and a duplicate was sampled on 07/05/2006 at 0746.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page I of 1

PERMITTEE NAME/ADDRESS (include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 SOjDDLY. DAISY_

TN 37384--------

Faiit aA -_SEQ UOYAH NUCLEAR PLANT......

Locatio~n HA,ýMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR FoI DISCHARGE MONITORING REPORT (DMR)

(UR0)O TN64065 j[

1 F -FINAL L2EA1I NMBER J IDISCHARGE NMUE BIOMONITORING FOR OUTFALL 101

______NITQRIN PER EFFLUENT rm Approved.

lB No. 2040-0004 I YEA I MOI DA YEARl4MO DAY From10 log101 To 06j09 3 NO DISCHARGE FEl..

NOTE: Read instructions before completina this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE

_________EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS IC5SAR DYCRSAMPLE Monitoring CEIDPN MEASUREMENT_

Not Required 2

MR3 EASREMENT-j-9

-`qiie PE::ENT SEE,.

COMPOS 0

0

. PEMIT

~z

-45.2 EFFLUENT

~~~~REQUIREMENT-.,,-,

.PRI IC25 STATRE 7DAY CHR SAMPLE Monitoring 2

PIMEPHALES MEASUREMENTNoReurd2 TRP6C 1 0

0 PERMIT.-~-.--.

52

-PRETSE CMO PECN PERM7t

.z1

REQUIREMENT

SAMPLE MEASUREMENT PERMIT:>

REQUIREMEI~ff SAMPLE MEASUREMENT PERMIT::--.,-

-REOUIREMENT:.

J.-

SAMPLE MEASUREMENT PERMIT,-

REQUIREMENT, SAMPLE MEASUREMENT PERMIT=;

,REQUIREMENT:,

NAME/TITLE PRINCIPAL EXECUTIVE OFFICER II Certify under penally of law that Ihis document and all attachments were prepared under my~

11 TELEPHONE DATE J.Rad Dde irection or supervision in accordance with a system designed t0 assure thaI qualified pesne J. R ndy ouetproperly gather and evaluate the information submitted. Based on my inquiry of the person or

~persons who manage the system, or those persons directly responsible for gathering the PicplEvrnetlEgne 2

4-70 0

0 0

Site Vice President information. the information subrmitted is, 10 the best of my knowledge and belief, true, PrincipalEnvironentalEngineer_42_843-6700_06_10_0 accurate. and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVEI information. including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA INUMBER YEAR MO DAY TYPED OR PRINTED ii____________________________

________________CODE COMMENTS AND EXPLANATION OF ANY VfIOLATIONS (Reference all attachments here)

Toxicity was not sampled in September 2006.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page I of 1

PERMITTEE NAME/ADDRESS (Include Facility Namre/Location if Djifferent)

Name TVA -SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 SODDY - DAISY TN 37384 Faciflity TVA-SEOUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR Form DISCHARGE MONITORING REPORT (DMR)

SB01OM TN0640103 G

FFINAL L

ERM!ITUMBERJ [R~AGEU LOW VOL. WASTE TREATMENT POND I

MO~NITOING PERIOD IEFFLUENT YEAR MO DAY YLEAR MO DAY NO DISCHARGE 7 From 06 1 T 1 0 09 30 NOTE: Read instructions before completinc

%pproved.

4o. 2040-0004 this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO. FREQUENCY SAMPLE

_________EX OF TYPE

> <AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS PH SAMPLE 65890 1/0 GA MEASUREMENT 65.912 0

1/0 GA 00400 1

0 0'-..PRI 6090SU THREEI GAB IEFFLUENT GROSS VALUE REOIRMEN...

WEE MINIMUM-........

MAXIMUM EE SOLIDS, TOTAL SUSPENDED SAMPLE 104 137 26 11 14 0

4/30 GRAB MEASUREMENT 1

00530 1

0 0

-- PERMIT--

-7 30.

15 LBS/DY

~010 MGIL WEEKLY

GRAB, REQUIREMENT' IEFFLUENT GROSS VALUE

-MO AG

'.'DAILY Mk-.

MO AVGý DAILY.MX',

OIL AND GREASE SAMPLE

<48 26

<5

<19 0

4/30 GRAB MEASUREMENT 2

51 0056 1 0PERMIT*,

~

9 5

LBS/DY

-1 1

0MGIL

'WEEKLY GA

-REOIJIREMENT~-

EFFLUENT GROSS VALUE MOAVG-.`

DAILY MX MO AVG".

DAILY MX_

FLOW, IN CONDUIT OR THRU SAMPLE 1.105 1.565 03 0

30/30 TOTALZ TREATMENT PLANT MEASUREMENT

~50050 1

0 0

PERMIT REOT RPORT,ý MGD SE.ý EFFLUENT GROSS VALUE REURMN -.MOAVG' D'AILY.k' MX:P.SERMTOTL SAMPLE MEASUREMENT

--PERMIT.--

-REQUIREMENT*.

SAMPLE MEASUREMENT SAMPLE MEASUREMENT

.PERMIT7

'REQUIREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penally of law that this document and alt attachments were prepared under my

~.

f p

ilTELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel PICULU-j(

J. Randy DoUet property gather and evaluate the information submitted. Based on my inquiry of the person or

~~

~

persons who manage the system. or those persons directly responsible for gathering the Principal Environmental Engineer 42 83-70 6

10 4

SiteVicePresdentinformation. the information submitted is. to the best of my knowledge and belief, true, 423____843-6700_______06__10___04_

Sit VcePreidntaccurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE information. including the possibility of fine and imprisonment tor knowing violations.

I FIE RATOIE GN RA NME ERM A

TYPED OR PRINTED OFFICER__ORAUTHORIZED__AGENTAREAINUMBER__YEARMO COY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all/attachments here)

Outfall 103 was closed on 09/03/2006 at 1450 and reopened on 09/05/2006 at 1038.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O0 BOX) 2000 SODDY - DAISY TN 37384 FacZiit

_DA -_SEOUOYAH NUCLEAR PLANT7 Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

SB01 TNO02450O 0

F -FINAL PERMIT NUMBER pI ISCARGE NUBERJ METAL CLEANING WASTE POND IMM.Q3IQRNG PERID EFFLUENT YEARL FYRIMO DA LD42~fAY NO DISCHARGE 1

From 0610101 To061 9 1 0 j NOTE: Read instructions before con Form Approved.

OMB No. 2040-0004 noletina this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE

_____EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS PH SAMPLE MEASUREMENT

    • 12 00400 1

0 0

  • ....PERMIT,..-,,**~
      • 60 SU DIY GRAB.

EFFLUENT GROSS VALUE

,EUREN MINIMUM~I..~

7Y MAXIMIUM SOLIDS, TOTAL SUSPENDED SAMPLE 1

MEASUREMENT 1

00530 1

0 0

..- ~.PERMIT ~.-.--.fh***-

0MGIL DAILY COMPOS REQUIREMENT-L EFFLUENT____

GRS VAU DAILYMNX`

OIL AND GREASE SAMPLE MEASUREMENT 19 00556 1

0 0

PERMIT--!:-.--.****.:

        • ...5 MGIL

-DAILY.

GRAB EFFLUENT GROSS VALUE RQIEET..

~

ALM PHOSPHORUS, TOTAL (AS P)

SAMPLE 19LYW MEASUREMENT 1

0065 1 0REQUIREMEN!::*ee*.-

-****j.y.*

MG/L

-DAILYý COMPO EFFLUENT GROSS VALUE ENT',

P

-OD1L M

COPPER, TOTAL (AS CU)

SAMPLE MX, 1

MEASUREMENT 1

01042 1

0 0

.PERMIT.

1.0 --

MGtL DAL-C PS EFFLUENT GROSS VALUE DA-LYIY M

IRON, OTAL (AS FE)

SAMPLE 19X" MEASUREMENT 1

0105 0 0 PR~T~-.~

.0 MGIL

-DAILY.

COMPOS EFFLUENT GROSS VALUEREIRMN.

ALYX-FLOW, IN CONDUIT OR THRU SAMPLE 03IYM TREATMENT PLANT MEASUREMENT 0

50050 1

0 0

."PERMIT

-`

RPR RPR MGD..................t***K "DIY CLT EFFLUENT GROSS VALUE CREQIREENT.

MO AVG! i-DAILY MX,___

NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my L-TEPOEDE J. Douet

~~~direction or supervision in accordance with a system designed to assure that qualified persone

~((Cl1-t-/

J.Randy D utproperly gather and evaluate the information submitted. Based on my inquiry of the person or el TELEPHONEfDATE persons w ho m anage the system, or those persons directly responsible for gathering the Pr n c p a E n i o m n aIni e r 2

4 - 7 0 00 0

Sie ic Pesdetaccurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE TYPED OR PRINTED information, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA NME ERM A

COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAMEIADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

-(INEROFIE S-A)

Ta--SODDY - DAISY -TN 37384 Faclitvy TVA - SEQOUYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(UI 1

TNll 026450Q 1

F -FINAL PE~RMITNUMBERJ [jIDICARGENtUýMBERJ RECYCLED COOLING WATER Form Approved.

OMB No. 2040-0004 O INC)G, EFFLUENT MO DY ER MO DAY

.. NOD From 06 J0 01J To YOA 9 3 NOTE:

ISCHARGE

[EýiiI*

Read instructions betore completing this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE

_________EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS TEMPERATURE, WATER DEG.

SAMPLE CENTIGRADE MEASUREMENT044 1000 z

0 T.PERMIT;.'-

DEG**,j.

C DE

-AIY..GA-100010 ZM MO0NITORING REU.M~

~-.-

i

-7 DAILY MX DEC DAL PH SAMPLE MEASUREMENT 12 00400 1

0 0

,.:PRI

.~n-6 0

9.

SU WEEKLY :-GRAB-REQUIREMENT, EFFLUENT GROSS VALUE.

.MNMMMX UM SOLIDS, TOTAL SUSPENDED SAMPLE 1

MEASUREMENT 1

00530 1

0 0

PERMIT;-,-v30.ý MGIL DAILYý.

COMPOS EFFLUENT GROSS VALUE REURMN

.DAILY MXm OIL AND GREASE SAMPLE MEASUREMENT 19 00556 1

0 0

--PERMIT:."'

GL DAILY GRAB EFFLUENT GROSS VALUEREUEMN DAL MX FLOW, IN CONDUIT OR THRU SAMPLE 03 TREATMENT PLANT MEASUREMENT 0

50050 1

0 0

.J,- PERMIT.-_'j' REPREPO R EPR MGD

,DAILY CALCTD REQUIREMENT'

RPRT, EFFLUENT GROSS VALUE M-,~.

.O"A V-G DAILY MX CHLORINE, TOTAL RESIDUAL SAMPLE

  • 1 MEASUREMENT 1

50060 1

0 0

EMT'--.

.10 MGIL WEEKLY GRAB-4, EFFLUENT GROSS VALUE REUREET

,.DAILY MX SAMPLE MEASUREMENT

.REOUIREMENT NAMEITITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attachments were prepared under my

~

-TELEPHONE DATE J. Do~~~~et

- j~~irection or supervision in accordance with a system designed to assure that qualified personnel n~J~C jIi 7

97.z J.Randy D utproperty gather and evaluate the information submitted. Based on my inquiry of the person or SiteVicePresdentinformation, the information submitted is, to the best of my knowledge and belief, true.

423____843-6700______06___10__04_

SiteVicePresdentaccurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVEI

-information, including the possibility of fine and imprisonment for knowing violations.

I OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY TYPED OR PRINTED

_____________________________j.CODE COMMENTS AND EXPLANATION OF ANY VIOLATIIONS (Reference all attachments here)

No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAMEJADDRESS (Include Facility Name/Location if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000------

SODDY.- DAISY TN 37384.......

Faiit RA-_SEOUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMRJ SB 1

TNO02650O1 F -FINAL LE1E~1ThU BE&JLDISCHARGE NU~E RECYCLED COOLING WATER IMONITO)RING PERIOD IEFFLUENT YEAR MO DAY YEAR MO DAY

.. NO DISCHARGE [M]

From 06 09 01 To 06 09 30 L

NOTE: Read instructions before Form Approved.

OMB No. 2040-0004 comolefina this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE

_________EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS IC25 STATRE 7DAY CHR SAMPLE 2

CERIODAPHNIA MEASUREMENT 2

TRP3B 1

0 0

PERMIT.

.452--..

PERCENT.

SEMI' COMPOS EFFLUENT GROSS VALUE

'REUIRMEN M.

ANNUA.LS PIMEPHALES MEASUREMENT 2

TRP6C 1

0 0

-z:PRT:-.-42 PERCENT SEI COMPOS MESUIREMENTý PERMU'.MITUA SAMPLE MEASUREMENT REQUIREMENTý.

SAMPLE MEASUREMENT

-..PERMIT;.

REQUIREMENT.

7-,

SAMPLE MEASUREMENT PEMIT

-7 SAMPLE MEASUREMENT

  • PERMIT,

'REQUIREMENT:

NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penally of law that this document and all attachments were prepared underm

~j~TLPOEDT direction or supervision in accordance wvith a system designed to assure that qualified persne my2

)C c J. Randy Douet Property gather and evaluate the information submitted. Based on my inquiry of the pers ronne orEH NEDT S it e V i c e P r e s i d e n tin fo rm a tio n, th e in fo rm a tio n su b m itte d is, to th e b e st o f m y k n o w le d g e a n d b e li f tru ep a E n v iro n m e n tal__

E n g in e er__

SiteVicePresdentaccurate. and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE TYE RPITDinformation. including the possibility of fine and imprisonment for knowing violations.

I OFFICER OR AUTHORIZED AGENT AREA NUMBER YEAR MO DAY No Discharge this Period EPA Form 3320-1 (REV 3199)

Previous editions may be use Page 1 of 1

PERMITTEE NAMEIADDRESS (Include Facility NamelLocation if Different)

Name TVA -SEQUOYAH NUCLEAR PLANT Address P.O.BOX2000 SODDY - DAISY _TN! 37384

'Facliy TVA - SEOUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR Form Approved.

DISCHARGE MONITORING REPORT (OMR)

SB01OMNo24004 TN06450 116 G F -FINAL PERMIT NUMBER

[pjSCHARGEN BER BACKWASH MONITORIN PERIOD EFFLUENT YEAR MO DAY YEA M.DY

. NO DISCHARGE From 06 9

0 1

o 1 6 109 30 NOTE: Read instructions before completing this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREOUENCY SAMPLE

_________EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS DEBRIS, FLOATING (SEVERITY)

SAMPLE 0*

9A a

1/ 30 VISUAL MEASUREMENT 01345 1

0 0

PERMIT RPR SS0

.".EE VUA IEFFLUENT GROSS VALUE REQIREEN I~.....-

. 0, PERMIT' OIL AND GREASE VISUAL SAMPLE 0

a 1/0 VSA MEASUREMENT 9

/0 VSA 84066 1

0 0

- PERMIT

.i>REPORTý'!

YES1

' SEE VISUAL:

IEFFLUENT GROSS VALUE REQUIREMENTT,

'-'"MO TOTAL NO0 SAMPLE MEASUREMENT

--PERMIT REQUIREMENT f

  • ~..

SAMPLE MEASUREMENT PERMIT-ý-,-.

REQUIREMENT SAMPLE MEASUREMENT PERMIT',:: ý-.

REQUIREMENT,.:*.7 SAMPLE MEASUREMENT

--- PERMIT.-

=77----*

REQUIREMENT' SAMPLE MEASUREMENT

ýPERMIT.

REQUIREME NT!-

NAMEITITLE PRINCIPAL EXECUTIVE OFFICER I Certify under penalty of law that this document and all attach~ments were prepared undemy

/,

~

j TELEPHONE DATE J. Douet direction or supervision in accordance with a system designed to assure that quatifie personnel

.T persons who manage the system, or those persons directly responsible for gath~ering the Principal Environmental Engineer 42 84-70 0

10 4

Site Vice President information, the information submitted is,* to the best of my lknowiedge and belief, true, 423____843-6700_____06___10__04_

accurate, and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVEI TYE RPITDinformation, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA INUMBER

  • YEAR MO DAY COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachmentts here)

Operations performs visual inspections for floating debris and oil and grease during all backwashes.

EPA Form 3320-1 (REV 3/99)

Previous editions may be used Page 1 of 1

PERMITTEE NAME/ADDRESS (Include Facility NameA~ocation if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.0 BOXý 2000 SOjDDLY. DAISY TN 37384 faciht W

TA - SEQUOYAH NUCLEAR PLANT Location HAMITO(N]COUDNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

SB01 TN6 265 0 117 G IF -FINAL L ~!TN:ý]~ [ DISHARGE NUMER BACKWASH IMONITO"I GPgERIQD I

FFLUENT

YEAR:

MO DAY YEARI MO DAY NO DIS From 06 109 01 To 06 109 130 NOTE: Re Form Approved.

OMB No. 2040.0004 CHARGE ElD

~ad instructions before com~Ietinq this form.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE

_________EX OF TYPE

> <AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS DEBRIS, FLOATING (SEVERITY)

SAMPLE 0

9A 0

1/I30 VISUAL MEASUREMENT 9

01345 1

0 0

ýPERMIT-`/',

EPR PASS=O

~

.SEE'-

VISUALý EFFLUENT GOSS VALUE REOUIREMENT.

MLOA

-p1_-'FAIL=l PEMI OIL AND GREASE VISUAL SAMPLE 0

40 11I 0

VISUAL MEASUREMENT 84066 1

0 0

2PEMT--"sRP tS YS1-,:***

SEE:

VISUAL

-,REQUIREMENT-SAMPLE MEASUREMENT

~REQUIREMENT; SAMPLE MEASUREMENT

.PERMIT-~-

RhEQUIREMENT.

SAMPLE MEASUREMENT

- PERMITý`

REQUIREMENT>

SAMPLE MEASUREMENT PERMIT.--

-REQUIREMEN-T NAME/TITLE PRINCIPAL EXECUTIVE OFFICER TI Certify under penally of law that Ihis document and all attachments were prepared under my

~.

f j

~

~

TELEPHONE DATE i-ection or super vision in accordance with a system designed to assure that qualified personnel m

J. Randy Douet

~~~properly gather and evaluate the information submitted. Based on my inquiry of the person or I~

Ipersons who manage the system. or those persons directly responsible for gathering the Principal Environmental Engineer 42 83-70 6

10 4

Site ice resient information, the information submitted is, to the best of my knowledge and belief, true.

423____843-6700______06___10__04_

StViePeietaccurate.

and complete. I am aware that there are significant penalties for submitting false SIGNATURE OF PRINCIPAL EXECUTIVE________

information, including the possibility of fine and imprisonment for knowing violations.

OFFICER OR AUTHORIZED AGENT AREA INUMBER

-YEAR MO DAY TYPED OR PRINTED I

I____________________________________________

I-CD COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

Operations performs visual inspections for floating debris and oil and grease during all backwashes.

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 1 of 1

PERMITTEE NAMEIADDRESS (Include Facility Namel~ocation if Different)

Name TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000 SODDY.- DAISY TN 37384 Faclit TVA - SEOUOYAH NUCLEAR PLANT

.Location HAýMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

SB 1

TNO02450 18 G IF

- FINAL PEMTNUMB3ER DISCHARGE NUMBER WASTEWATER & STORM WATER YERI MONITORING-PRO EFFLUENT YERM DAY YEAR MO DY O

ICAREE1 From 06 109 101 To _06 09 30CAREI^^

Form Approved.

OMB No. 2040-0004 intefinri fhi~ fnrm PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

FREQUENCY SAMPLE

_____EX OF TYPE AVERAGE MAXIMUM UNITS MINIMUM AVERAGE MAXIMUM UNITS ANALYSIS OXYGEN, DISSOLVED (DO)

SAMPLE MEASUREMENT 19 00300 1

0 0

-.PERMIT-.-'--

~

~

'*~***

MOIL 7TVVICEI GRAB-EFFLUNT GRSS VAUE

-REQUIREMENTL YJ<.-$.;;i&:.-I,-ý-.-

q..

EFLETGOSVAU DAILYMN..............,.

WEEK.

SOLIDS, TOTAL SUSPENDED SAMPLE

  • 1 MEASUREMENT 1

00530 1

0 0

PERMITJ.;f '. ~.****.-..-

.****..:10MGIL K

TWVICEI

'GRAB EFFLUENT GROSS VALUE REUREET-

-~

,DIYM

.WE SOLIDS, SETTLEABLE SAMPLE

  • 2 MEASUREMENT 2

.00545 1

0

. 0 PERMIT-4.-;;-

-1.0:

M/LA ONCE/

GRAB EFFLUENT GROSS VALUE REURMN

'~-

~

~-

~

AILY M.W" MONTH-.

FLOW, IN CONDUIT OR THRU SAMPLE 0

TREATMENT PLANT MEASUREMENT 0

50050 1

0 0

PEP0RT.`-

REPOR

'ý,`REPORT GD ONCE/

ESTIMA EFFLUENT GROSS VALUE RE

.IEM-MO AV AL X.-.......

.~ BATCH SAMPLE MEASUREMENT REQUIREMENT-'

SAMPLE MEASUREMENT PERMIT-,--,-

REtQUIREMEN-f SAMPLE MEASUREMENT PERMIT..

REQUIREMENT NAME/TI-TLE PRINCIPAL EXECUTIVE OFFICER I Certify under penally of law that this document and all attachments were prepared under my jTELEPHONE DATE direction or supervision in accordance with a system designed to assure that qualified personnel

,t.~.(t~~lc.c J. Randy Douet property gather and evaluate the information submitted. Based on my inquiry of the person or Persons who manage the systetm. or those persona directly responsible for gathering the {

Principal Environmental Engineer 42 83-70 0

10 4

SiteVicePresdentinformation. the information submitted is.* to the best of my knowledge and belief. true.

423____843-6700_____0____10__04_

Sit VcePreidntaccurate, and complete. I am aware that there are significant penalties for submitting fatte SIGNATURE OF PRINCIPAL EXECUTIVEI

__________________________information. including the possibility of fine And imprisonment for knowing violations.

I OFFICER OR AUTHORIZED AGENT AREA INUMBER YEAR MO DAY TYPE ORPITDI____________________________I_______________

CODE COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

During this reporting period, there has been no flow from the Dredge Pond other than that resulting from rainfall.