Attachment 1 Modified Handling Requirements for the Protection of Certain Safeguards Information (SGI-M)

General Requirement Information and material that the U.S. Nuclear Regulatory Commission (NRC) determines are safeguards information must be protected from unauthorized disclosure. In order to distinguish information needing modified protection requirements from other safeguards information that requires a higher level of protection, the term Safeguards Information-Modified Handling (SGI-M) is being used as the distinguishing marking for this information. Each person who produces, receives, or acquires SGI-M shall ensure that it is protected against unauthorized disclosure. To meet this requirement, licensees and persons shall establish and maintain an information protection system that includes the measures specified below. Information protection procedures employed by state and local police forces are deemed to meet these requirements.

Persons Subject to These Requirements Any person, whether or not a licensee of the NRC, who produces, receives, or acquires SGI-M is subject to the requirements (and sanctions) of this document. Firms and their employees that supply services or equipment to materials licensees would fall under this requirement if they possess facility SGI-M. A licensee must inform contractors and suppliers of the existence of these requirements and the need for proper protection. (See more under Conditions for Access)

State or local police units who have access to SGI-M are also subject to these requirements.

However, these organizations are deemed to have adequate information protection systems.

The conditions for transfer of information to a third party, i.e., need-to-know, would still apply to the police organization as would sanctions for unlawful disclosure. Again, it would be prudent for licensees who have arrangements with local police to advise them of the existence of these requirements.

Criminal and Civil Sanctions The Atomic Energy Act of 1954, as amended, explicitly provides that any person, whether or not a licensee of the Commission, who violates any regulations adopted under this section shall be subject to the civil monetary penalties of section 234 of this Act. Furthermore, willful violation of any regulation or order governing safeguards information is a felony subject to criminal penalties in the form of fines or imprisonment, or both. See sections 147b. and 223 of the Act.

2 Conditions for Access Access to SGI-M beyond the initial recipients of the order will be governed by the background check requirements imposed by the order. Access to SGI-M by licensee employees, agents, or contractors must include both an appropriate need-to-know determination by the licensee, as well as a determination concerning the trustworthiness of individuals having access to the information. Employees of an organization affiliated with the licensees company, e.g., a parent company, may be considered as employees of the licensee for access purposes.

Need-to-Know Need-to-know is defined as a determination by a person having responsibility for protecting SGI-M that a proposed recipients access to SGI-M is necessary in the performance of official, contractual, or licensee duties of employment. The recipient should be made aware that the information is SGI-M and those having access to it are subject to these requirements as well as criminal and civil sanctions for mishandling the information.

Occupational Groups Dissemination of SGI-M is limited to individuals who have an established need-to-know and who are members of certain occupational groups. These occupational groups are:

A.

An employee, agent, or contractor of an applicant, a licensee, the Commission, or the United States Government; B.

A member of a duly authorized committee of the Congress; C.

The Governor of a State or his designated representative; D.

A representative of the International Atomic Energy Agency (IAEA) engaged in activities associated with the U.S./IAEA Safeguards Agreement who has been certified by the NRC; E.

A member of a state or local law enforcement authority that is responsible for responding to requests for assistance during safeguards emergencies; or F.

A person to whom disclosure is ordered pursuant to Section 2.709(f) of Part 2 of Title 10 of the Code of Federal Regulations.

G.

State Radiation Control Program Directors (and State Homeland Security Directors) or their designees.

In a generic sense, the individuals described above in (A) through (G) are considered to be trustworthy by virtue of their employment status. For non-governmental individuals in group (A) above, a determination of reliability and trustworthiness is required. Discretion must be exercised in granting access to these individuals. If there is any indication that the recipient would be unwilling or unable to provide proper protection for the SGI-M, they are not authorized to receive SGI-M.

3 Information Considered for Safeguards Information Designation Information deemed SGI-M is information the disclosure of which could reasonably be expected to have a significant adverse effect on the health and safety of the public or the common defense and security by significantly increasing the likelihood of theft, diversion, or sabotage of materials or facilities subject to NRC jurisdiction.

SGI-M identifies safeguards information which is subject to these requirements. These requirements are necessary in order to protect quantities of nuclear material significant to the health and safety of the public or common defense and security.

The overall measure for consideration of SGI-M is the usefulness of the information (security or otherwise) to an adversary in planning or attempting a malevolent act. The specificity of the information increases the likelihood that it will be useful to an adversary.

Protection While in Use While in use, SGI-M shall be under the control of an authorized individual. This requirement is satisfied if the SGI-M is attended by an authorized individual even though the information is in fact not constantly being used. SGI-M, therefore, within alarm stations, continuously manned guard posts or ready rooms need not be locked in file drawers or storage containers.

Under certain conditions the general control exercised over security zones or areas would be considered to meet this requirement. The primary consideration is limiting access to those who have a need-to-know. Some examples would be:

Alarm stations, guard posts and guard ready rooms; Engineering or drafting areas if visitors are escorted and information is not clearly visible; Plant maintenance areas if access is restricted and information is not clearly visible; or Administrative offices (e.g., central records or purchasing) if visitors are escorted and information is not clearly visible.

Protection While in Storage While unattended, SGI-M shall be stored in a locked file drawer or container. Knowledge of lock combinations or access to keys protecting SGI-M shall be limited to a minimum number of personnel for operating purposes who have a "need-to-know" and are otherwise authorized access to SGI-M in accordance with these requirements. Access to lock combinations or keys shall be strictly controlled so as to prevent disclosure to an unauthorized individual.

4 Transportation of Documents and Other Matter Documents containing SGI-M when transmitted outside an authorized place of use or storage shall be enclosed in two sealed envelopes or wrappers. The inner envelope or wrapper shall contain the name and address of the intended recipient, and be marked both sides, top and bottom with the words Safeguards Information - Modified Handling. The outer envelope or wrapper must be addressed to the intended recipient, must contain the address of the sender, and must not bear any markings or indication that the document contains SGI-M.

SGI-M may be transported by any commercial delivery company that provides nation-wide overnight service with computer tracking features, US first class, registered, express, or certified mail, or by any individual authorized access pursuant to these requirements.

Within a facility, SGI-M may be transmitted using a single opaque envelope. It may also be transmitted within a facility without single or double wrapping, provided adequate measures are taken to protect the material against unauthorized disclosure. Individuals transporting SGI-M should retain the documents in their personal possession at all times or ensure that the information is appropriately wrapped and also secured to preclude compromise by an unauthorized individual.

Preparation and Marking of Documents While the NRC is the sole authority for determining what specific information may be designated as SGI-M, originators of documents are responsible for determining whether those documents contain such information. Each document or other matter that contains SGI-M shall be marked "Safeguards Information - Modified Handling" in a conspicuous manner on the top and bottom of the first page to indicate the presence of protected information. The first page of the document must also contain (i) the name, title, and organization of the individual authorized to make a SGI-M determination, and who has determined that the document contains SGI-M, (ii) the date the document was originated or the determination made, (iii) an indication that the document contains SGI-M, and (iv) an indication that unauthorized disclosure would be subject to civil and criminal sanctions. Each additional page shall be marked in a conspicuous fashion at the top and bottom with letters denoting Safeguards Information -

Modified Handling.

In addition to the Safeguards Information - Modified Handling markings at the top and bottom of each page, transmittal letters or memoranda which do not in themselves contain SGI-M shall be marked to indicate that attachments or enclosures contain SGI-M but that the transmittal does not (e.g., When separated from SGI-M enclosure(s), this document is decontrolled).

In addition to the information required on the face of the document, each item of correspondence that contains SGI-M shall, by marking or other means, clearly indicate which portions (e.g., paragraphs, pages, or appendices) contain SGI-M and which do not. Portion marking is not required for physical security and safeguards contingency plans.

All documents or other matter containing SGI-M in use or storage shall be marked in accordance with these requirements. A specific exception is provided for documents in the

5 possession of contractors and agents of licensees that were produced more than one year prior to the effective date of the order. Such documents need not be marked unless they are removed from file drawers or containers. The same exception applies to old documents stored away from the facility in central files or corporation headquarters.

Since information protection procedures employed by state and local police forces are deemed to meet NRC requirements, documents in the possession of these agencies need not be marked as set forth in this document.

Removal from SGI-M Category Documents containing SGI-M shall be removed from the SGI-M category (decontrolled) only after the NRC determines that the information no longer meets the criteria of SGI-M. Licensees have the authority to make determinations that specific documents which they created no longer contain SGI-M information and may be decontrolled. Consideration must be exercised to ensure that any document decontrolled shall not disclose SGI-M in some other form or be combined with other unprotected information to disclose SGI-M.

The authority to determine that a document may be decontrolled may be exercised only by, or with the permission of, the individual (or office) who made the original determination. The document shall indicate the name and organization of the individual removing the document from the SGI-M category and the date of the removal. Other persons who have the document in their possession should be notified of the decontrolling of the document.

Reproduction of Matter Containing SGI-M SGI-M may be reproduced to the minimum extent necessary consistent with need without permission of the originator. Newer digital copiers which scan and retain images of documents represent a potential security concern. If the copier is retaining SGI-M information in memory, the copier cannot be connected to a network. It should also be placed in a location that is cleared and controlled for the authorized processing of SGI-M information. Different copiers have different capabilities, including some which come with features that allow the memory to be erased. Each copier would have to be examined from a physical security perspective.

Use of Automatic Data Processing (ADP) Systems SGI-M may be processed or produced on an ADP system provided that the system is assigned to the licensee's or contractor's facility and requires the use of an entry code/password for access to stored information. Licensees are encouraged to process this information in a computing environment that has adequate computer security controls in place to prevent unauthorized access to the information. An ADP system is defined here as a data processing system having the capability of long term storage of SGI-M. Word processors such as typewriters are not subject to the requirements as long as they do not transmit information off-site. (Note: if SGI-M is produced on a typewriter, the ribbon must be removed and stored in the same manner as other SGI-M information or media.) The basic objective of these restrictions is to prevent access and retrieval of stored SGI-M by unauthorized individuals, particularly from remote terminals. Specific files containing SGI-M will be password protected to preclude access by an unauthorized individual. The National Institute of Standards and Technology

6 (NIST) maintains a listing of all validated encryption systems at http://csrc.nist.gov/cryptval/140-1/1401val.htm. SGI-M files may be transmitted over a network if the file is encrypted. In such cases, the licensee will select a commercially available encryption system that NIST has validated as conforming to Federal Information Processing Standards (FIPS). SGI-M files shall be properly labeled as Safeguards Information - Modified Handling and saved to removable media and stored in a locked file drawer or cabinet.

Telecommunications SGI-M may not be transmitted by unprotected telecommunications circuits except under emergency or extraordinary conditions. For the purpose of this requirement, emergency or extraordinary conditions are defined as any circumstances that require immediate communications in order to report, summon assistance for, or respond to a security event (or an event that has potential security significance).

This restriction applies to telephone, telegraph, teletype, facsimile circuits, and to radio.

Routine telephone or radio transmission between site security personnel, or between the site and local police, should be limited to message formats or codes that do not disclose facility security features or response procedures. Similarly, call-ins during transport should not disclose information useful to a potential adversary. Infrequent or non-repetitive telephone conversations regarding a physical security plan or program are permitted provided that the discussion is general in nature.

Individuals should use care when discussing SGI-M at meetings or in the presence of others to insure that the conversation is not overheard by persons not authorized access. Transcripts, tapes or minutes of meetings or hearings that contain SGI-M shall be marked and protected in accordance with these requirements.

Destruction Documents containing SGI-M should be destroyed when no longer needed. They may be destroyed by tearing into small pieces, burning, shredding or any other method that precludes reconstruction by means available to the public at large. Piece sizes one half inch or smaller composed of several pages or documents and thoroughly mixed would be considered completely destroyed.