Text
M M
S S
S EM-102A EM-102B 3-SIH-150-143-1(Z-)
3-SIH-150-144-1(Z-)
3-SIH-150-141-1(Z-)
3-SIH-150-142-1(Z-)
V V
V V
26902 SH 2 26902 SH 1 LMC D
8810B 8902C 8902A 8902B 8902D 926 927 924 (Z-)
(Z-)
(Z-)
925 (Z-)
3-SIH-150-30-1(Z-)
3-SIH-150-31-1(Z-)
3-SIH-150-28-1(Z-)
3-SIH-150-29-1(Z-)
LMC LO 3-SIH-150-30-1(Z-)
3-SIH-150-31-1(Z-)
3-SIH-150-28-1(Z-)
3-SIH-150-29-1(Z-)
8903C 8903D 8903A 8903B (Z-)
LMC D
8815 3-SIH-003-26-1(Z-)
3-SIH-750-77-2(Z-)
Z 51 3-SIH-750-91-2(Z-)
HS MB2 HS MB2 8882 (Z-)
8843 8843 (ZO)
(ZO)
FC C1A 3-SIH-750-92-4 A/S A/S C
3-SIH-750-136-4 FC V881 V882 D
LMC 3-SIH-750-92-4 V819 V820 D
NOTES:
FLUSHING ONLY. STRAINER ELEMENT TO BE REMOVED AFTER PREOPERATIONAL FLUSHING AND STRAINER BODY TO BE ROTATED 180.
o 3-SIH-003-23-2(Z-)
3-SIH-004-147-2(Z-)
C HS MB3 C
SIS 3-SIH-750-130-4 REACTOR PLANT GASEOUS DRAINS CL 152 8963 V986 8962 3-SIH-750-129-4 3-SIH-002-148-4 V980 8845A 3-SIH-002-149-4 3-SIH-750-128-4 V979 8845B FI 928B FI 928A V977 V935 FC D
LMC 8964 (ZP) 8964 (ZP)
C A/S HS MB2 EM-113B K-4 26913 SH 2 3-SIH-750-42-2(Z-)
PI 929 8961 Z
99 3-SIH-750-127-2(Z-)
V LMC 3-SIH-750-126-2(Z-)
FC C
HS MB2 8871 (ZO) 8871 (ZO)
A/S V983 V936 D
LMC 3-SIH-750-79-4 V888 3-SIL-750-72-4 3-SIL-001-95-4 3-SIL-001-97-4 3-SIL-750-63-4 3-SIL-001-92-4 3-SIL-001-93-4 3-SIL-750-78-4 3-SIL-750-54-4 EM-112B EM-112B EM-112B EM-112B EM-112B EM-112B EM-112B EM-112B D-6 A-6 26912 SH 2 26912 SH 2 26912 SH 2 26912 SH 2 26912 SH 2 26912 SH 2 26912 SH 2 26912 SH 2 LOW PRESSURE SAFETY INJECTION LOW PRESSURE SAFETY INJECTION LOW PRESSURE SAFETY INJECTION LOW PRESSURE SAFETY INJECTION LOW PRESSURE SAFETY INJECTION LOW PRESSURE SAFETY INJECTION LOW PRESSURE SAFETY INJECTION LOW PRESSURE SAFETY INJECTION 3-SIH-001-76-4 EM-113B M-4 26913 SH 2 M
M (ZO)
SIS 3-SIH-004-102-2(Z-)
(ZP) 3-SIH-004-22-2(Z-)
3-SIH-004-16-2(Z-)
8836A 8836B FT 917 3-SIH-004-16-2(Z-)
3-CHS-004-68-2(Z-)
D D
3CHS 3CHS 3CHS 3CHS 8468A (AO) 8468B (BP) 112E (BP) 112D (AO)
C C
HS ASP HS ASP HS MB3 HS MB3 AUX BLDG PIPE TUNNEL 3-CHS-008-673-2(Z-)
3-SIH-004-93-2(Z-)
M D
3-SIH-008-85-2(Z-)
LOW PRESSURE SAFETY INJECTION EM-112A C-3 26912 SH 1 CL 153 CL 1502 HC 941 3-SIH-001-97-4 CL 153 CL 1502 LC 8884 3-SIH-004-94-4 3-SIH-001-98-4 V30 M
V991 8874 D
3-SIH-001-99-4 LC V33 V945 8886 V31 CL153 CL 1502 RV 8885 HIGH PRESSURE SAFETY INJECTION SS/RTL DHM/DEK/WS RWA 4/1/82 4/6/82 4/14/82 4/14/82 71-156 OMB IMB D
A/S 2.
EM-107A D-6 V
W. SHERMAN/F. FORTINI W. F. KOLAITIS 8801A 8801B S
CL 1502 CEM/WD M
2 1/2 "
AUX BLDG CONTMT STRUCT AUX BLDG CONTMT STRUCT
- 3. TEMPORARY STRAINER INSTALLED FOR PREOPERATIONAL FI 917 I
I I
I I
I I
ESF BLDG M
HCV 941 PS 979 3-SIH-750-96-4 SET AT 3,325 PSIG TO ATM SET AT 2,735 PSIG 3-SIH-001-163-4 3-SIH-750-162-2 3-SIH-003-80-2(Z-)
- V885(Z-)
3-SIH-003-26-1(Z-)
- V887(Z-)
3-SIH-003-114-1(Z-)
SV 8882 MB3 V
FC HY 941 HS I
L-9 J-6 C-11 F-10 G-6 H-9 REACTOR COOLANT REACTOR COOLANT REACTOR COOLANT REACTOR COOLANT 26907 MISCELLANEOUS ABBREVIATIONS AND SYMBOLS:
LMC LEAKAGE MONITORING CONNECTION OMB OUTSIDE MISSILE BARRIER IMB
- INSIDE MISSILE BARRIER SAFETY CLASS CHANGE POINT S
S
- RV 8870 (Z-)
- V808(Z-)
HYDRO TEST PUMP 3SIH-P3 PLANT DRAINAGE EM-157D G-10 26957 SH 4
- V809(Z-)
S S
S 8810A 8810D 8810C FOR CONTROLS AND CHARGING PUMPS HOOKUP SEE EM-104A (H-9,10,11) AND EM-104D (D-11) 3-SIH-001-95-4 L
LO OIL PRESS STOP P3 CLOSE CV CIA GR1 MB2 CLOSE MV CIA GR1 MB2 OPEN MV ZA MB2 GR2 MB2 GR2 MB2 OPEN MV ZA MB2 CLOSE CV GR1 MB2 NO.
DATE REVISIONS BY CHK.
APP.
MF CORR P.A.#
Q.A.
NUCLEAR SAFETY RELATED QA CAT. I, I I
- V812(Z-)
- V992(Z-)
- V993(Z-)
- MV
- MV
- LCV
- LCV
- V902(Z-)
- V834(Z-)
- V3(Z-)
- V906(Z-)
- V905(Z-)
- V903(Z-)
- V904(Z-)
- V54(Z-)
- V53(Z-)
- MV
- MV
- V4(Z-)
- V5(Z-)
- V989(Z-)
- V66(Z-)
- V69(Z-)
- V70(Z-)
- V6(Z-)
- V67
- V68(Z-)
- V9(Z-)
- V74(Z-)
- V73(Z-)
- V8(Z-)
- V7(Z-)
- V886(Z-)
- FE
- FE
- FE
- FE
- V953(Z-)
- V952(Z-)
- V955(Z-)
- V954(Z-)
- V71(Z-)
- V72(Z-)
- V836(Z-)
- V837(Z-)
- V65(Z-)
- CV
- SV
- AV
- V999(Z-)
- CV
- CV
- SV
- SV
- V937(Z-)
- V984(Z-)
- V985(Z-)
- V938(Z-)
- V987(Z-)
- V988(Z-)
113A A-8 B-5 26902 SH 5 EM-102E J-8 EM-102D J-9 26902 SH 4 38
- RO (Z-)
LC LC LT LT LT LT
- 4. DELETED.
917 (Z-)
- FE
- RO 40 (Z-)
41
- RO (Z-)
39
- RO (Z-)
5.
DELETED N
V V898
- V901(Z-)
V LMC V
NOTE 9 NOTE 9 NOTE 9 NOTE 9 6.
7.
8.
DELETED.
9.
LOCKING OF ECCS THROTTLING VALVES 3SIH*V6(Z-),
3SIH*V7(Z-), 3SIH*V8(Z-), 3SIH*V9(Z-), 3SIH*V21(A-),
3SIH*V23(B-), 3SIH*V25(B-), 3SIH*V27(A-), 3SIH*V107(A-),
3SIH*V108(A-), 3SIH*V109(B-) AND 3SIH*V111(B-) IS ACCOMPLISHED BY REMOVAL OF THE HANDWHEEL AND INSTALLING A LOCKNUT WITH LOCKWIRE.
UPSTREAM AND DOWNSTREAM SPOOLPIECES IN LINE 3-SIH-750-155-4 TO LINES 3-SIH-001-99-4 AND 3-CHS-750-761-4, RESPECTIVELY, REMOVED AND END FLANGES BLANKED WHEN NOT IN USE FOR HYDROTESTING.
3-SIH-750-155-4 EM-104A D-10 26904 SH 1 NOTE 6 CHEMICAL AND VOLUME CONTROL N/A INCORP. DCN DM3-00-1161-97 AC 17 TJY PAM PAM 10-22
-97 RFL N/A KF 18 INCORP. DCNS DM3-00-0479-97 & DM3-02-0479-97
- 10. SINGLE GLOBE VALVES ON VENTS OR DRAINS ARE SPECIAL CASES AND ARE NOT TO BE CAPPED AS PRESSURE RETAINING.
IF PRESSURE IS 1200 PSI OR GREATER, INSTALLED CAPS (CL 901)
ARE TO BE DRILLED OUT WITH A 1/4 " DIA. HOLE. A SOCKET WELDED BY THREADED COUPLING MAY BE INSTALLED IN PLACE OF A THREADED CAP FOR THE CLOSURE OF A SINGLE GLOBE VALVE VENT OR DRAIN WHERE THE SECOND GLOBE VALVE WAS REMOVED FOR SEISMIC LOADING REASONS. PLUGS SHALL NOT BE INSTALLED IN THE COUPLINGS. HOWEVER, FOR LEAK MONITORING CONNECTIONS WHERE THIS CONDITION EXISTS, A PLUG SHALL BE INSTALLED, DRILLED OUT WITH A 1/4 " HOLE. THE COUPLING SHALL COMPLY TO THE APPLICABLE PIPE CLASS OF THE VENT OR DRAIN ASSEMBLY.
D LMC LMC V
- V990(Z-)
- V883(Z-)
LC LC 1/4 " DIA.
HOLE 1/4 " DIA.
HOLE M
RFL AJS RWS RWS 1-17
-98 FSAR FIGURE 11.
THE SYSTEM OPERATIONS PROCEDURE GOVERNS THE POSITIONING OF VALVES AND DAMPERS (OPEN/ CLOSED/ LOCKED). VALVE/ DAMPER POSITIONS DEPICTED ON THE P&ID ARE FOR GUIDANCE ONLY.
REFER TO THE SPECIFIC PROCEDURE FOR VERIFICATION OF VALVE/
DAMPER POSITION.
N/A KF 19 INCORP. DCN DM3-00-0682-98 7-28
-98 RFL RJK RFL 1"
3/4 "
3CHS*P3A(AO) 3CHS*P3C(SG) 3CHS*P3B(BP) 1/2 "
1/2 "
1/2 "
1/2 "
(SEE NOTE 12) 12.
3CHS*V261 ALL VENT, DRAIN, TEST AND SAMPLE CONNECTIONS ARE 3/4 " UNLESS OTHERWISE NOTED.
13.
3-SIH-001-1-4 3-SIH-750-92-4 1 1/4 "
VENDOR SUPPLIED PUMP 3SIH-P3 AND ITS ASSOCIATED COMPONENTS WERE INSTALLED FOR START-UP ONLY. THEY ARE RETIRED IN PLACE AND NOT INTENDED TO BE RE-USED.
3-CHS-008-672-2(Z-)
ALL VENT, DRAIN, TEST AND SAMPLE CONNECTIONS TO BE CLASS 4 DOWNSTREAM OF THE FIRST VALVE UNLESS OTHERWISE NOTED.
3/4 "
FE 928 N/A INCORP. DCN DM3-00-0184-99 CMC 20 7-9
-99 RJK AJS MP IN THE PREFIX FOR EQUIPMENT OR INSTRUMENTS WHICH ARE A PART OF NUCLEAR SAFETY FEATURES SYSTEM.
1.
N/A 21 INCORP. DCN DM3-00-0394-00 RFL ALL INSTRUMENT AND EQUIPMENT NUMBERS FOR HIGH PRESSURE SAFETY INJECTION TO BE PREFIXED WITH "3SIH-" EXCEPT WHERE A DIFFERENT PREFIX IS SHOWN.
AN ASTERISK (*) WILL REPLACE THE DASH (-)
CSJ AJS PFL 11-2
-00 M
N N/A 22 9-6
-02 INCORP. DCN DM3-00-0226-02 SMH 113A DLW TF DCZ V934 V982 V897 LO 23 INCORP. DCN DM3-00-0324-02 JBB DLW TF TMS 10-31
-02 S
D N
N/A N/A 24 INCORP. DCN DM3-01-0324-02 DLW 25212-26913 SH 1 OF 2 24 ASK WBZ MP 5-9
-05 REV BY DATE SCALE CHKD.
DATE APP.
DATE DWG. NO.
APP.
DATE TITLE STONE & WEBSTER ENGINEERING CORPORATION BOSTON, MASS.
NONE MICROFILM DATE PIPING & INSTRUMENTATION DIAGRAM REVISIONS DURING CONSTRUCTION REV.
DATE DESCRIPTION BY CHK CORR APP S&W DWG. NO.12179-EM-RESP. ENGR:
DESN. ENGR:
12179-EM-A B
C D
E F
G H
I J
K L
M N
4 OPERATIONS CRITICAL P.A. No.
9 1
2 3
5 6
7 8
4 9
1 2
3 5
6 7
8 10 11 NOTE:
MANUAL REVISIONS TO THIS DOCUMENT WHEN AS-BUILT ARE PROHIBITED.
CAD MILLSTONE POWER STATION-UNIT NO. 3 R
Dominion Nuclear Connecticut, Inc.
Millstone Power Station STONE & WEBSTER ENGINEERING CORPORATION BOSTON, MASS.
OPERATIONS CRITICAL STONE & WEBSTER ENGINEERING CORPORATION BOSTON, MASS.
OPERATIONS CRITICAL OPERATIONS CRITICAL OPERATIONS CRITICAL OPERATIONS CRITICAL