UNIVERSITY OF CALIFORNIA, IRVINE BERKELEY

  • DAVIS -

IRVINE -

LOS ANGELES -

RIVERSIDE -

SAN DIEGO

  • SAN FRANCISCO I 4:

I SANTA BARBARA -

SANTA CRUZ George E. Miller Senior Lecturer Emeritus Department of Chemistry and Supervisor, Nuclear Reactor Facility US Nuclear Regulatory Commission Document Control Desk Mail Station P 1-137 Washington, D.C. 20555 IRVINE, CA 92697-2025 (949) 824-6649 FAX: (949) 824-6082 or (949) 824-8571 Internet: GEMILLER@uci.edu July 24, 2006 Re:

Docket 50-326: License R-1 16 Annual Report Submittal, Tech Spec 6.7f Ladies/Gentlemen:

Please find enclosed three(3) copies of the annual report for the UCI Nuclear Reactor Facility, covering the period July 1st 2005 through June 30th 2006.

Sincerely, George E. Miller Reactor Supervisor cc:

American Nuclear Insurance, 95 Glastonbury Blvd, Glastonbury CT 06033, Policy NF-176 Craig Bassett, US Nuclear Regulatory Commission One White Flint North, 11555 Rockville Pike, Rockville, MD 20852-2738 Reactor Operations Committee Members, UCI Dean of Physical Sciences, John Hemminger AO&Do

U. C. IRVINE Nuclear Reactor Facility Annual Report for July 1st 2005 to June 30th 2006 Facility License R-1 16 Docket 50-326 Prepared in Accordance with Part 6.7f of the Facility Technical Specifications by Dr. G. E. Miller Reactor Supervisor UCI Nuclear Reactor Facility Annual Report 2005-2006 Page I

Section 1.

Operations Summar Operation of this facility is in support of the Department of Chemistry program of research and education regarding application of radioisotopes and radiochemical techniques in chemical studies.

Reactor utilization, apart from operator training and maintenance, is thus entirely for sample irradiation. Samples come from diverse origins related to forensic science, fossil fuels, geochemistry, art, and archaeological studies, chemical synthesis, industrial quality control, enzyme studies, trace element pollution studies, etc. The reactor is also used in class work by undergraduates learning tracer and activation analysis techniques using small, quantities of short-lived activated materials.

Enrollment in Winter Quarter 2006 was 38 students.

Use is also made of the facility by other educational institutions. This program has involved tours, class demonstrations, and analyses of samples submitted by faculty. No support was obtained from the Reactor Sharing program for this year, but some support was available from participation in Western Nuclear Science Alliance (WNSA) since September 2004.

Support was granted for instrumentation upgrade from the URI program of the US Department of Energy for a Compton Suppression Gamma Spectrometer System to be assembled from the grant, existing equipment and loan equipment. Upgrades have been made to security system hardware, including camera surveillance systems as part of a continued program of security compensatory measures, using UCI funding.

Operations have been maintained similar to last year. Criticality was achieved for 99 hours0.00115 days <br />0.0275 hours <br />1.636905e-4 weeks <br />3.76695e-5 months <br />, and the total energy generated was equivalent to 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br /> at full steady state power. 71 experiments were performed, and nearly 1700 samples were irradiated (sometimes multiple samples are included in a single capsule and are not always separately logged). 18 low-moderate level isotope shipments were made (Yellow II category or less). No pulse operations have been performed, even for test purposes.

An NRC general inspection was carried out during November 2005 (151, -18tI1).

A follow up item concerns the lack of an Operator Requalification program now that only one operator is at the facility. Former Senior Operator, Dr. Pat Rogers last operated on May 20"~ 2005.

A local, California, Homeland Security review was conducted on June 29h", 2006. So far no recommendations or criticisms have' been forthcoming regarding security arrangements.

Monthly inspections continue to be routine from the EH&S Office at UCI. These continue to identify log entries that are not fully explained and apparent lack documentation of follow-up on identified items noted. No significant safety or maintenance problems were encountered during this reporting period.

Two trainee operator continued to practice operations under supervision during this period. One left for graduate school in San Diego in September, 2005, the other, an EH&S employee, left UCI employment on June 3 0'h 2006 for a State of California position.

UCI Nuclear Reactor Facility Annual Report 2005-2006 Pg Page 2

Section 2.

Data Tabulations for the Period July 1st, 2004 to June 30th, 2005 TABLE I.

Experiment Approvals on file Experiments performed (including repeats)

Samples irradiated Energy generated this period (Megawatt hours)

Total, 69 element core

=

127.0

>74 element core = 1292.5 Total energy generated since initial criticality 8

71 1685+

14.9 1419.5 Mwh Pulse operation this period Total reactor pulses to 6/30/06 0

978 Hours critical this period Total hours critical to date Inadvertent scrams or unplanned shutdowns 95.2 8189.1 3

Visitors to reactor - as individuals or in tour groups -

Maximum dosimeter recorded for visitors - all less than Visiting researchers (dosimeter issues)

Maximum exposure recorded at one visit Visiting researchers (badged)

TABLE II Reactor Status 6/30/05 (unchanged from 6/30/04)

Fuel elements in core (including 2 fuel followers)

Fuel elements in storage (reactor tank - used)

Fuel elements unused (4 instrumented elements + 1 element + 1 FFCR)

Graphite reflector elements in core Graphite reflector elements in reactor tank storage Water filled fuel element positions Experimental facilities in core positions Non-fuel control rods Total core positions accounted for 293 1 mrem 99 2.89 mrem 4

Core excess, cold, no xenon (as of 6/28/2006)

Control rod worths (calibrated 1/13/05)

REG SHIM ATR FTR Total:

82 25 6

34 0

6 4

2 127

$2.65

$2.43

-Mw 0.°C

$2.83

$3.60

$1.77

$0.66

$8.86 Maximum possible pulse insertion Maximum peak power recorded (no pulse operation during this period)

Maximum peak temperature recorded in pulse (B-ring)

UCI Nuclear Reactor Facility Annual Report 2005-2006 Page 3

Section 3.

Inadvertent Scrams and Unplanned Shutdowns TABLE III.

Date Time Power Type and Cause 2005 7/28 10:05 ca 7.5 kw Linear Power scram during power increase to 250 kw. Auto range changing failed to initiate. Cause unknown, not reproduced, no recurrence.

2006 2/28 9:43 5/19 9:31 250 kw High voltage failure scram. No identifiable origin. Not reproducible.

No recurrence.

250 kw Linear Power scram @ 105%. Log reads 95%, %P reads 100%.

Probably cooling water surge increased power indication while not closely observed. Restarted to slightly lower power margin.

UCI Nuclear Reactor Facility Annual Report 2005-2006 Page 4

Section 4 Maintenance and Surveillance The following non-routine maintenance activities were carried out during this period. Some reactor operation related items have been included above and are not repeated here.

2005 July 14: Wide Range Linear Monitor Isolation amplifier output stage was rebuilt with new electrolytic capacitors and re-installed to perform to original specifications.

July 12-14: sensor upgrades made to security reporting system. Checks performed on all systems demonstrated satisfactory reporting performance.

November 4th. micro-actuator switch replaced with a new one on RSR (Lazy Susan) "auto" rotate mechanism. The old arm fractured on Oct 26th.

December 25h: CAM hi alarm received - indicated 40% DAC "spike". Filter showed no abnormality on gamma counting (nothing above background). Concluded it was electronic problem - no recurrence found. However may have been related to problem on Jan 9 th 2006 (below) 2006 January 9: CAM failure alarm reported - low flow rate observed. Replaced filter and reset.

January 21: recurrence of CAM low flow incident. Filter replaced and device OK. However air pump is probably failing to maintain good flow. The frequency of new filter installation was increased to compensate.

January 26: seismic scram found to have tripped (reactor not operating) as a result of construction/deconstruction work on outside of adjacent wall.

March 29: key locks replaced during entire building re-key. New keys issued to authorized persons.

May 13: CAM low air flow again. Installed new air pump to fix problem. Flow increased from ca.

24 to ca 45 L/min.

June 15: construction/deconstruction work loosened plaster on ceiling in rear lab. Did not affect system ability to maintain negative facility pressure. Plans set for repair by patch using steel plate to secure.

Jun 2 1st: power dip to RH building (and campus) caused motion alarm to be sent. Facility inspected and alarm reset.

Section 5 Facility Changes and Special Experiments Approved All changes in security systems resulted in increased incident response capability.

No special or unusual experiments were approved during this period.

UCI Nuclear Reactor Facility Annual Report 2005-2006 Page 5

Section 6 Radioactive Effluent Release.

(a) Gases.

The major direct release to the environs is Argon-41 produced during normal operations.

Very small amounts of other gases may be released from irradiated materials in experiments.

Releases are computed based on original estimates at point of origin within the facility and taking only dilution into account. Since much of the release is from operation of the pneumatic transfer system for samples, this is a conservative estimate in that assumption is made that all use of the PT is at full steady state power level (250 kW) when, in fact, some use is with the reactor at a lower power level. In view of the small numbers involved, and the fact that an integrated dose check is provided by an environmental dosimeter (CaSO 4-Dy) hanging directly in the exhaust at the point of stack discharge, it is considered unnecessary to provide further checks of these estimates. The dosimeter data confirm that an individual standing directly in the exhaust flow for one year would receive an additional submersion dose from the exhaust less than the reliability limit of the dosimeters, or less than 20 mrem per year. The dosimeter data are presented separately in Section 7.

Table IV. Over the years that data have been collected, the accumulated exposure at the exhaust location have been lower than for "control" points because of lower masses of concrete structures in the vicinity. In fact the data have been consistently at 20-25 mrem per year background level, so confidence of exposure less than 5 mrem over background seems possible.

Release estimates based on operational parameters are as follows:

(1) Operation of pneumatic transfer system (7/1/05-6/30/06):

a. Minutes of operation:
b. Release rate assumed:
c. Flow rate of exhaust air:

Total release computed: (a x b x c) =

(2) Release from pool surface (7/1/05-6/30/06):

a. Total hours of operation at power (Mwh x 4) =
b. Release rate assumed:
c. Flow rate of exhaust air:

Total release computed: (a x 60 x b x c) 335 minutes

6. x 10"8 microcuries/mL 1.2 x 108 mLmin.

2.4 x 103 microcuries 59.6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />

<1. x 10-8 microcuries/mL 1.2 x 108 mL/min.

4.3 x 103 microcuries

d. Total of (1) and (2) emission in 1 year

= 6.7 x 103 microcuries

e. Total effluent released in 1 year (525960 minutes/yr. x c) = 6.3 x 1013 mL Concentration averaged over 12 months (d/e)

= ~ 1.1 x 1010 microcuries/mL Since 20 x 10-10 microcuries/mL provides an annual exposure for constant immersion of 10 mrem, this corresponds to < 0.5 mrem potential additional radiation exposure to an individual standing breathing in the effluent stack for the entire year.

This is similar to values reported in previous years and assumes no dilution of the plume at or beyond the stack. It also assumes all PT operation is at full 250 kw power.

UCI Nuclear Reactor Facility Annual Report 2005-2006 Page 6

Section 6. (continued)

(b) Liquids and Solids.

Liquid and solid wastes from utilization of by-product materials are disposed through a University contract. Waste is transferred to the custody of the Campus Environmental Health and Safety Office (EH&S). Disposals to this custody are given below. It is important to note that activity values are estimated at the time of transfer to EH&S control. Since few shipments are being made from campus, decay to negligible levels occurs for all medium-lived radionuclides. Teaching course items (used for training in liquid scintillation counting techniques) may be a mixture of reactor generated byproducts and purchased materials (exclusively 14C and 3H).

DRY WASTES:

9/7/05 2 ft3 dry waste containing less than 100 microcuries of mixed activation products (including 60Co and shorter-lived products) from irradiation experiments.

02/23/062 ft3 dry waste containing less than 100 microcuries of mixed activation products (including 60Co, shorter-lived products, and some purchased 3H and 14C) from irradiation experiments.

LIQUIDS:

02/27/06 1.5 gallons LSC waste (in water) est: 20 microcuries 3H and 10 microcuries "'C.

Section 7.

Environmental Surveillance.

Calcium Sulfate/Dysprosium thermoluminescent dosimeters have been placed at nine locations around the UCI Campus for many years. Starting July 1 2004, the is provided by Global Dosimetry Solutions (GDS), Costa Mesa, California. The GDS packs have three chips in each pack which are averaged for exposure recording. One pack is kept on the edge of campus in a wood frame house in University Hills.

Contamination surveys consisting of wipe tests and G-M surveys have shown mostly a "clean" facility with significant, removable contamination only in areas coming into direct contact with samples removed from the reactor, and on sample handling tools. Trash is surveyed before disposal and not disposed unless found to be free of removable and fixed contamination.

Table of Locations for Environmental Dosimeter Packs.

1. Window of reactor room east wall (inside the facility).
2. In hallway on exterior of south wall of facility (inside building).
3. *Loading dock, adjacent to west wall of reactor room.
4. Laboratory 152, directly over reactor facility, approximately over core center.
5. In roof exhaust air flow from reactor room, roof level (hung in center of duct at final release point).
6. Biological Sciences 2 building, 5th floor, laboratory near window*.
7. Main library building across campus, 5th floor office in sunny window
8. Computer Science building, 4th floor office, in shaded window.
9. Fume hood exhaust, roof level, from reactor laboratory (hung in center of duct).
10. 12 Perkins Court, University Hills, private residence (wood frame house).
  • location moved inside the wall of the facility as of January 2006.

UCI Nuclear Reactor Facility Annual Report 2005-2006 Page 7

TABLE IV.

Environmental Dosimetry Data.

2004-2005 Average Total Exposures in mrem (including "control background")

Location.

1. S. Facility perimeter
2. W. Facility perimeter
3. N Facility perimeter
4. Lab Room over facility
5. Facility main air exhaust
6. Bio. Sci II top floor
7. Library top floor
8. Computer Sci. top floor
9. Facility fume hood exh.
10. Faculty housing Background control Quarter Annual 2/05 3/05 4/05 1/06 Total 2005/6 41 40 30 45 156 26 24 21 28 99 27 24 22 xx 73 25 22 22 27 96 25 21 19 25 90 2004/5 182*

102 107 99 96 Prior year Excess over control (05-6)

Totals mr 53

-4

(-13) 3 q only

-7

-13

-5 23

-23

-11

-23 0

26 31 20 22 20 29 24 30 20 24 19 23 21 31 19 21 19 25 27 34 21 25 22 26 98 126 80 92 80 103 101 127 87 96 83 105

  • exposure due to proximity of Cs-137 irradiator and stored Cf-252 source.

xx item destroyed during deconstruction work outside building Discussion Raw data is presented here, along with control comparisons. Within this range, the data vary significantly.

Data for this year reflects two issues:

" all but the location 1 and 7 are within control background level.

" Location 1 is a hallway with an extremely low occupancy rate. (See additional note below),

location 7 is remote at the top of a 5 story building which must have a low absorbing roof?

Exposure estimated to a single individual in an uncontrolled area at this facility is still very minimal.

Locations 1 and 2 are in or near hallways with extremely minimal occupancy or travel, especially since recent security changes resulted in permanently locked doors to the hallways on this floor level (access only to individuals with building keys). Location 3 is on an outside loading dock also with low occupancy. The laboratory overhead (location 4) is casually occupied by very few individuals (one or two at the most) in the space above the reactor core. The air released from the facility (measured by locations #5 and #9) continues to give no detectable exposure above background for dosimeters immersed in it. Location 7 consistently shows higher readings presumably because it is in a window at the top of a 5 story building above a warm, outside, cement wall. The cement may have higher U and Th levels. The roof may have low absorbance. Over many years, the data at each specific location has shown remarkable consistency. The net conclusion is that, compared to distant control areas (numbers 7 and 10), we are operating fully ALARA as far as public exposure potential is concerned.

UCI Nuclear Reactor Facility Annual Report 2005-2006 Page 8

Section 8.

Radiation Exposure to Personnel.

UCI issues TLD badges to most students or researchers utilizing radiation. Finger dosimetry (TLD) rings are also issued to personnel who mightbe regularly handling isotopes. Dosimeters are read quarterly by Global Dosimetry Solutions, and results are presented in Table V. Reporting categories have changed since last year's report to read DEEP, EYE, and SHALLOW.

6 persons were issued dosimeters on a continual basis; 5 were also issued with finger dosimeters. 38 students and 3 teaching assistants in a radiochemistry class were also issued TLD dosimeters and used "Canary II" direct reporting dosimeters on a regular basis. The latter typically showed only 0.05 mR for background during a 3 hour3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> period in lab exercises. Class badges were kept in the lab for the entire quarter along with small sources used in experiments. Thus class dosimeter values include background as well as the approximately 30 total hours of actual lab work done.

Visiting individuals and tour groups are issued with direct-reading Canary II digital monitor instruments that record in units of 0.01 mR so low exposure information is available. Background levels during a tour visit typically accumulates 0.03-0.05 mR during a 45 minute visit to the facility.

In the past this was recorded as "0", so it will continue to be referred to in that way. Any reading of 0.10 or above will be tabulated. In the past only readings in excess of 1 mR would have been noted.

Individuals working on facility general maintenance were also issued Canary II Dosimeters. All work was done with the reactor shut down, and no readings >0.05 were found. Data for the second quarter 2006 were not available as of this report, so these reflect 9 months of operations.

TABLE V.

Personnel Exposure Report Summary for 7/1/05 to 3/30/06 (in mrem)

Individuals Whole Body Finger Ring DEEP EYE SHALLOW (Shallow) 1 43 106 162 579 30 30 30 65 12 0

0 0

32 1

0 0

0 0

12 0

0 0

0 1,

0 0

0 not issued 4 14 0-50 0-50 0-50 not issued (assumed 2050 total)

(assumed 2050 total)

(assumed 2050 total)

Totals 2123 2186 2242 676

1. This individual does extensive activation analysis and radiochemical work at the facility. Most of the exposure is a result of CI-38 radioactivity production.
2.

Individuals receiving exposure as a result of operator/trainee and/or calibrating activities in the facility.

3. Individuals who did NOT ENTER THE FACILITY AT ALL during this period, so badge exposure is an indication of range of general background within the facility, where the badges are stored.
4.

Students and teaching assistants in radiochemistry class Jan-March 2004.

Aggregated non-zero data from self-reading dosimeters issued to researchers in addition to TLD badges are:

Persons Admissions Accumulation (mrem) 1 7

5.15 1

5 4.18 1

2 6.75 45 45

<0.10 Summation 57 16.18 As noted earlier, 293 visitors were monitored using self-reading digital dosimeters (each individual, or 3-8 dosimeters per group when in a group). No readings >0.10 mrem were recorded for these tour events. Personnel exposures continue to be very low at this facility in keeping with ALARA efforts.

UCI Nuclear Reactor Facility Annual Report 2005-2006 Page 9