ML062130463

From kanterella
Jump to navigation Jump to search

License Amendment Request 05-005, Revision to Technical Specification 3.7.10, Control Room Emergency Filtration/Pressurization System - Letter Re NRCs Initial Review
ML062130463
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 08/18/2006
From: Thadani M
NRC/NRR/ADRO/DORL/LPLIV
To: Blevins M
TXU Power
Thadani M, NRR/DORL, 415-1476
References
TAC MC8163, TAC MC8164
Download: ML062130463 (4)


Text

August 18, 2006 Mr. M. R. Blevins Senior Vice President &

Chief Nuclear Officer TXU Power Attn: Regulatory Affairs Department P. O. Box 1002 Glen Rose, TX 76043

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION, UNITS 1 AND 2 -

LICENSE AMENDMENT REQUEST (LAR)05-005, REVISION TO TECHNICAL SPECIFICATION 3.7.10, CONTROL ROOM EMERGENCY FILTRATION/PRESSURIZATION SYSTEM (CREFS) (TAC NOS. MC8163 AND MC8164).

Dear Mr. Blevins:

The Nuclear Regulatory Commission (NRC) staff has completed its initial review of the TXU Generation Company LPs (licensees) proposed license amendment request (LAR)05-005, dated August 22, 2005, for Comanche Peak Steam Electric Station (CPSES), Units 1 and 2.

The licensee requested a revision to Technical Specification (TS) 3.7.10, Control Room Emergency Filtration/Pressurization System (CREFS). It is our understanding that the submittal by CPSES is intended to revise TS 3.7.10 to address periodic verification of control room leakage and adds two new TSs, 5.5.20 and 5.6.11, Control Room Integrity Program and Control Room Report, respectively.

The purpose of this letter is to convey the NRC staffs concerns, identified by our initial review of LAR 05-005.

The licensee stated that the acceptance limits used in the new Control Room Integrity Program will be based on assumptions of the radiological dose consequences calculations. The licensee also stated that CPSES is adopting new methods and assumptions as described in Regulatory Guide (RG) 1.195, Methods and Assumptions for Evaluating Radiological Consequences of Design Basis Accidents at Light-Water Nuclear Power Reactors, May 2003. The licensee stated that, in discussions with the NRC's staff, it learned that adoption of RG 1.195 is contingent upon adoption of RG 1.196, Control Room Habitability at Light-Water Nuclear Power Reactors, May 2003, and RG 1.197, Demonstrating Control Room Envelope Integrity at Nuclear Power Reactors, May 2003.

The licensee further stated in its submittal that it plans to complete Commitment Number 27301 and plans to submit a TS change to include periodic verification of control room in-leakage by September 30, 2004, or within 90 days after TS Task Force (TSTF) Standard TS Change Traveler TSTF-448 is available for use, whichever is later. The purpose of this letter is to state that the licensees adoption of RGs 1.195, 1.196, and 1.197, as presented in the submittal, and completion of Commitment Number 27301, as described above, create a problem. We find that the TS change presented in the current submittal (i.e., periodic verification of control room

M. R. Blevins in-leakage) is unacceptable for several reasons, which include the use of the 550 days allowed outage time to restore the control room envelope to operable status. In addition, TSTF-448 is not available for use at this time, and its future availability for use is uncertain. Therefore, the NRC staff cannot move forward with the proposed request LAR 05-005, and recommends that you withdraw LAR 05-005 and resubmit it after TSTF-448 becomes available.

Please advise us within 30 days from the date of this letter of your decision to withdraw the license amendment or provide an alternative on how to resolve the above issues in an effective manner.

Sincerely,

/RA/

Mohan C. Thadani, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-445 and 50-446 cc: See next page

M. R. Blevins 2 in-leakage) is unacceptable for several reasons, which include the use of the 550 days allowed outage time to restore the control room envelope to operable status. In addition, TSTF-448 is not available for use at this time, and its future availability for use is uncertain. Therefore, the NRC staff cannot move forward with the proposed request LAR 05-005, and recommends that you withdraw LAR 05-005 and resubmit it after TSTF-448 becomes available.

Please advise us within 30 days from the date of this letter of your decision to withdraw the license amendment or provide an alternative on how to resolve the above issues in an effective manner.

Sincerely,

/RA/

Mohan C. Thadani, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-445 and 50-446 cc: See next page DISTRIBUTION PUBLIC LPLIV Reading RidsOgcRp RidsAcrsAcnwMailCenter RidsNrrDorlLpl4 RidsNrrPMMThadani RidsNrrLAJBurkhardt RidsRgn4MailCenter RidsNrrDraAcvb (RDennig)

DWalker, NMSS ACCESSION NO: ML062130463 OFFICE NRR/LPL4/PM NRR/LPL4/LA NRR/LPL4/BC NAME MThadani LFeizollahi DTerao DATE 8/17/06 8/17/06 8/18/06 OFFICIAL RECORD COPY

December 2004 Comanche Peak Steam Electric Station cc:

Senior Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 2159 Glen Rose, TX 76403-2159 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 Mr. Fred W. Madden, Director Regulatory Affairs TXU Generation Company LP P. O. Box 1002 Glen Rose, TX 76043 George L. Edgar, Esq.

Morgan Lewis 1111 Pennsylvania Avenue, NW Washington, DC 20004 County Judge P. O. Box 851 Glen Rose, TX 76043 Environmental and Natural Resources Policy Director Office of the Governor P. O. Box 12428 Austin, TX 78711-3189 Mr. Richard A. Ratliff, Chief Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin, TX 78756-3189 Mr. Brian Almon Public Utility Commission William B. Travis Building P. O. Box 13326 1701 North Congress Avenue Austin, TX 78701-3326 Ms. Susan M. Jablonski Office of Permitting, Remediation and Registration Texas Commission on Environmental Quality MC-122 P. O. Box 13087 Austin, TX 78711-3087 Terry Parks, Chief Inspector Texas Department of Licensing and Regulation Boiler Program P. O. Box 12157 Austin, TX 78711