ML062090083

From kanterella
Jump to navigation Jump to search
E-mail K. Mcmullin (Entergy) to J. Boska (Nrc/Nrr) Et. Al., IPEC Status Report for May 18, 2006
ML062090083
Person / Time
Site: Indian Point  
Issue date: 05/18/2003
From: Mcmullin K
Entergy Corp
To: Boska J, Cobey E, Brian Holian, Diane Jackson, David Lew
Office of Nuclear Reactor Regulation
References
FOIA/PA-2006-0244
Download: ML062090083 (5)


Text

Page 1 of 2 Uf61inlbdska - IPEC status report for May 18 2006.doc From:

"McMullin, Kathleen M" <KMcMull@entergy.com>

To:

<Popopeek@aol.com>, "Baranski, James" <james.baranski@semo.state.ny.us>, " Eddy, Paul" <paul-eddy @ dps.state.ny.us>, " Greeley, Dan" <greeleyd@co.rockland.ny.us>,"

Gross, Steve - Orange PIO" <sgross@co.orange.ny.us>, " Sutton, Tony"

<awsl @westchestergov.com>, <AStiebeling@pcbes.org>, "Albanese, Raymond"

<rla 1 @ westchestergov.com>, "Alfredo Vidal" <avidal @ thevidalgroup.com>,

<aws 1 @ weschestergov.com>, "B. Gore" <bgore @ urbanomics.com>,

<bakerna@co.rockland.ny.us>, "Barry, Terrence" <TBarry@entergy.com>, "Benjamin, Liz" <BenjamiL@co.rockland.ny.us>, "Bentley, Robyn M" <rbentle@entergy.com>,

<ken.bergmann@semo.state.ny.us>, "Bernie McGarry" <mcgarry@senate.state.ny.us>,

"Blizard, Andrea J" <ablizar@entergy.com>, <rjo4@westchestergov.com>,

<jeanbordewich@schumer.senate.gov>, <schumer@valstar.net>, <jpbl @nrc.gov>,

"Bowman, Greg " <GBowm90@cc--exsO3.prod.entergy.com>, <beh@nrc.gov>,

<JBridges @troopers.state.ny.us>, "Chief Tubbs" <ChiefBTubbs @ aol.com>, "Chris Schwarz" <cschwar@entergy.com>, <ewc@ nrc.gov>, "Comiotes, Jim"

<JComiot@entergy.com>, "Conroy, Patric W" <PConroy@entergy.com>,

<lindac@yorktownny.org>, "Cox, Mark R" <mcox90@ entergy.com>,

<Gcrawford@urbanomics.com>, "Curran, Nick" <Nick.curran@mail.house.gov>,

"Dacimo, Fred R" <FDacimo@entergy.com>, "David Brand"

<DavidPBrand@hotmail.com>, "David Greene" <dgreene@urbanomics.com>, "David Weinraub" <DWeinraub@bmwlobby.com>, "DeGasperis, Edward M"

<edegasp@entergy.com>, "DiRocco, Anthony J" <ADirocc@entergy.com>,

<Donald.Maurer@semo.state.ny.us>, "Dowling, Adele" <amd2@westchestergov.com>,

<Barney.Drew@lafarge-na.com>, <elisagwilliam@msn.com>, "Fay, Deborah"

<DFayl @entergy.com>, "Feathers" <jdf@ fcwc-law.com>,

<Andrew.Feeney @ semo.state.ny.us>, <peter.feroe @mail.house.gov>, "Geri Shapiro"

<gerishapiro@aol.com>, <Emily.Gibbons@mail.house.gov>, "Giguere, Kathleen M"

<KGiguer@entergy.com>, <grtroes@nppd.com>, "Gottlieb, Laurence"

<LGottli @ entergy.com>, "Greene, Dominick" <dgreene @ co.orange.ny.us>,

<gac7 @ westchestergov.com>, "Grosjean, Alain G" <AGrosje@ entergy.com>,

<Frank.Guiao @lafarge-na.com>, "Harry Giannoulis" <harry @theparksidegroup.com>,

"Hinrichs, Gary H" <ghinric@entergy.com>, "Hipschman, Thomas"

<thips90 @ entergy.com>, "Inzirillo, Frank A" <finziri @ entergy.com>, "Ira Promisel"

<ipromise@troopers.state.ny.us>, "Jack Spath" <jps@nyserda.org>, <dej 1 @nrc.gov>,

<jefft @ townofcortlandt.com>, "Jensen, Chris" <jensenc @ co.rockland.ny.us>, "JES"

<JES1 @westchestergov.com>, "Jim Cunningham" <jim cunningham@nyc.bm.com>, "Jim Wright" <wright@senate.state.ny.us>, "John Cordo" <JLC@fcwc-law.com>, "Jones, T. R."

<tjones2@entergy.com>, "Kansler, Michael R" <MKansle@entergy.com>, "Kathleen Wood" <kathleen.wood@chamber.state.ny.us>, <Pat.keegan@mail.house.gov>, "Kems, Matthew T" <MKems@entergy.com>, <MKopy@troopers.state.ny.us>,

<kevin.kraus @ semo.state.ny.us>, "L. Leach" <lionelleach @ yahoo.com>, "Leach, Don"

<DLeach@entergy.com>, <leibell @senate.state.ny.us>, "Leon, Pete"

<Pete.Leon @mail.house.gov>, <DCL @ nrc.gov>, "Longo, Nick"

<longon @ co.rockland.ny.us>, "Mark Serrano" <serrano @ proactivecom.com>, "Martin-\\'

Brennan" <MartinBrennan@schumer.senate.gov>, "Marvin Randolph" file://C:\\temp\\GW ) 00001.HTM 7/25/2006

Date:

Subject:

Page 2 ot 2

<mrandolph @ urbanomics.com>, "Mayer, Donald M" <DMayerl @ entergy.com>,

"McCann, John (ENNE Licensing Director)" <jmccanl @entergy.com>, "McCannell, Chris" <Chris.mccannell @ mail.house.gov>, "McConaghy, Ryan"

<ryanMcConaghy@schumer.senate.gov>, "McGillicuddy, Maura"

<MMcGill@entergy.com>, "McKay, Mike" <mike.mckay@mail.house.gov>, "McMahon, Bob - Putman County" <cdrbob3l @aol.com>, "McMullin, Kathleen M"

<KMcMull @ entergy.com>, <millera @ assembly. state. ny.us>,

<MillerC @ co.rockland.ny.us>, "Mitchell, Frank J" <FMitche @ entergy.com>, "Neil Sheehan" <nas@ nrc.gov>, <rand @ schildasset.com>, <jdn @nrc.gov>,

<Joseph.o'brien@mail.house.gov>, <boliveira@amnucins.com>, <doneill@bghc-law.com>, "Pat Brown" <PBrown@bmwlobby.com>, "Paul Steidler"

<paul@effectivecomm.org>, "Paul Tonko" <tonkop@assembly.state.ny.us>, "Paulson, Adam" <adam.paulson@mail.house.gov>, <alp@nyserda.org>, "Phillips, Frank M"

<fphilli@entergy.com>, <pjk3 @westchestergov.com>, "Poquette, Thomas"

<thomas.poquette @ lafarge-na.com>

5/18/2006 5:28 PM IPEC status report for May 18 2006.doc See attached 7/25/2006 file://C:\\temp\\GW }00001.HTM

Al SEntery Indian Point Energy Center Status Report May 18, 2006 Operational Status - 2R17 Outage Indian Point Unit 2 remains in MODE 3 at Normal Operating Temperature (NOT) and Normal Operating Pressure (NOP). Today crews are clearing the Vapor Containment of materials and equipment. Most secondary (steam) side equipment is being returned to service including stator water cooling, condensate and circulating water pumps.

Unit 3 is operating at 100% reactor power and has been on-line for 226days.

Above left, is a picture of a Main Boiler Feed Pump. The MBFP pumps waterfront the condensate system back to the steam generators. On the right of the pump is the internal rotor which was cleaned and inspected during this outage. The two MBFP's are turbine driven pumps that supply the steam generators with reheated waterfront the feedwater heaters.

At left, Entergy engineers inspect the close out of the high pressure turbine.

SEnlerXy Ground water Investigation Update As part of the ongoing groundwater investigation various monitoring wells installed on site are being analyzed for radioactivity and other contaminants. Entergy has recently received sample results for strontium-90 from a number of Phase 2 wells which are located near Unit 1 and in the vicinity of Unit 3.

These wells were sampled by the State of New York, NRC, and Entergy on an independent split sample basis to compare results.

Sr-90 Tritium Results Results ID Depth Location Date (pCi/L)

(pCiVL)

MW-41 41' South of IP3 RWST 4/12/2006 2.63 726 63' 4/12/2006 5.5 701 MW-43 28' South of IP3 Tank 4/12/2006

< 2 346 62' 4/12/2006

<1.2 200 MW-46 30' IP3 Transformer Yard 4/12/2006

<1.2 1380 These sample results are consistent with Unit 1 being the source of Sr-90 in groundwater although additional water sampling and other analysis techniques such as soil sampling will be done to further evaluate the results above. Entergy is also conducting a review of previous contamination events in these areas and historic use of the areas as a possible cause for the presence of strontium 90.

These sample results are bounded by and do not change the results of previous dose calculations that show potential dose impacts that are <.1% of federally allowable levels. [As a point of reference, the drinking water standard for Sr-90 is 8 pCi/L and for tritium is 20,000 pCi/L)]. There are no drinking water sources on or near the site and no off-site samples have shown any detectable levels of radioactivity from plant operations.

Twelve new wells, Phase 2A wells, are being installed starting in the next two weeks to help quantity groundwater flow and contamination locations. A map showing locations of the new wells in relationship to the existing wells was previously included with the status report.

Educational Outreach Entergy Nuclear Northeast provides customized outreach education programs for schools, youth groups, and civic organizations. The topics we cover include Emergency Planning, Understanding Radiation, Nuclear Fuel and a general overview of the operations of Indian Point Energy Center. If you would like a

Enlergy brochure or are interested in scheduling a program, contact IPEC Communications at 914-271-7441.

If you have any questions or need clarification of the information provided, please contact Kathy McMullin, manager of communications, Indian Point Energy Center, at 914-271-7132.