OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION July 11,2006 Mr. Wfiam Snell U.S. Nuclear Regulatory Commission Region 111 2443 Warrenville Road Lisle, IL 60532-4351
SUBJECT:
FINAL LETTER REPORT FOR ANALYTICAL RESULTS FOR FIFTY-FIVE WATER SAMPLES, BATCH FIVE, FROM THE VICINITY OF THE DRESDEN GENERATING STATION, DRESDEN, ILLINOIS
[INSPECTION REPORT NO. 050-00237/2006-007] (RFTANO.06-001)
Dear Mr. Snell:
The Oak Ridge Institute for Science and Education (ORISE) received 55 water samples on June 20,2006 which were collected in the vicinityof the Dresden Generating Station in Dresden, Ihois. The samples were analyzed for tritium. The chaimof-custody identified 11 water samples to he analyzed by gamma spectroscopy (GS). The sample identifications and collection data are presented in Table 1. The GS data are presented in Table 2. The tritium data are presented in Table 3. The data for sample D-06-5-03 is qualified due to the lack of sample volume needed for the distiiation procedure. The sample volume, as received, was approximatelythree mL. The peninent procedure references are provided in the specific tables.
ORISE's Quality Control (Qc) requirements were met for these analyses. The ($2 files are available for your review upon request.
My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.
Dale Condra, Manager Laboratory RDC:WPI:ess C:
B. Watson, NMSS/DWMEP/DD/SP 7E18 E. Abelquist, ORISE E. Knox-Davin, NRG'NMSS/TWFN8A23 G. Bonano, NRC Region 111 S. Kirk ORISE File 1694
~~
y n Distribution approval and concurrence : I Initials Fcshnical M&gcrnent Tt,m Mernbcr Voice: 865.241.3242 Fax: 865.241.3248 E - d : CondraD@orau.gov RECEIVED JUL 1 82006
TABLE 1 SAMPLE IDENTIFICATIONS AND COLLECTION DATA DRESDEN GENERATING STATION DRESDEN, ILLINOIS
TABLE 1 (continued)
SAMPLE IDENTIFICATIONS AND COLLECTION DATA DRESDEN GENERATING STATION DRESDEN, ILLINOIS
TABLE 2 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN SELECTED WATER SAMPLES BY GAMMA SPECTROSCOPY CP1, REVISION 15 DRESDEN GENERATING STATION DRESDEN, ILLINOIS
'?he range of MDO for the selected radionuclides Is 4.7 p W L to 12.0 pWL.
%Jncertaintier represent rhe 95% confidence level, bared on total propagated unceminrier.
Dresden Generating Station
TABLE 3 CONCENTRATIONS OF TRITIUM IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 15; CP4, REVISION 3 DRESDEN GENERATING STATION DRESDEN, ILLINOIS 2060 170
TABLE 3 (continued)
CONCENTRATIONS OF TRITIUM IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 15; CP4, REVISION 3 DRESDEN GENERATING STATION DRESDEN, ILLINOIS
- hll)Cr arc in parcnthescs.
"Uncertainties rcprereot the 95% coofidencc IcvcI, based on total propagated uncertainties.
"I'hc ccsdcs for this samplc are qualificd due to an insufficient samplc volume needed fur thc distillation pcocedurc.
- d. der" values are due to rounding.
l~rcsdcn < ;cncrarinl: Stat,<>"
prolccrs/1694/13nta 'l~blcs/2llll6.~l7~l I 'I'nblcs Ihtch ~ I I C